    VAR-201808-1010

    Vulnerability from variot - Updated: 2024-11-23 22:00

    Stack-based Buffer Overflow vulnerability in libUPnPHndlr.so in Belkin Wemo Insight Smart Plug allows remote attackers to bypass local security protection via a crafted HTTP post packet. Belkin Wemo Insight Smart Plug Contains a buffer error vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. BelkinWemoInsightSmartPlug is a smart plug device from Belkin, USA. A stack buffer overflow vulnerability exists in the libUPnPHndlr.so file in BelkinWemoInsightSmartPlug

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-201808-1010",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "wemo insight smart plug",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "belkin",
            "version": null
          },
          {
            "model": "wemo insight smart plug",
            "scope": null,
            "trust": 1.4,
            "vendor": "belkin",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2018-16502"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-009336"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201808-653"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-6692"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "cpe_match": [
                  {
                    "cpe22Uri": "cpe:/o:belkin:wemo_insight_smart_plug_firmware",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-009336"
          }
        ]
      },
      "cve": "CVE-2018-6692",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "COMPLETE",
                "baseScore": 10.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 10.0,
                "id": "CVE-2018-6692",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 1.9,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "PARTIAL",
                "baseScore": 7.5,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2018-16502",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "VULHUB",
                "availabilityImpact": "COMPLETE",
                "baseScore": 10.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 10.0,
                "id": "VHN-136724",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.1,
                "vectorString": "AV:N/AC:L/AU:N/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 10.0,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "id": "CVE-2018-6692",
                "impactScore": 6.0,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "author": "trellixpsirt@trellix.com",
                "availabilityImpact": "NONE",
                "baseScore": 5.9,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 2.2,
                "id": "CVE-2018-6692",
                "impactScore": 3.6,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:N",
                "version": "3.0"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 10.0,
                "baseSeverity": "Critical",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "CVE-2018-6692",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Changed",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2018-6692",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "trellixpsirt@trellix.com",
                "id": "CVE-2018-6692",
                "trust": 1.0,
                "value": "MEDIUM"
              },
              {
                "author": "NVD",
                "id": "CVE-2018-6692",
                "trust": 0.8,
                "value": "Critical"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2018-16502",
                "trust": 0.6,
                "value": "HIGH"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-201808-653",
                "trust": 0.6,
                "value": "CRITICAL"
              },
              {
                "author": "VULHUB",
                "id": "VHN-136724",
                "trust": 0.1,
                "value": "HIGH"
              },
              {
                "author": "VULMON",
                "id": "CVE-2018-6692",
                "trust": 0.1,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2018-16502"
          },
          {
            "db": "VULHUB",
            "id": "VHN-136724"
          },
          {
            "db": "VULMON",
            "id": "CVE-2018-6692"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-009336"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201808-653"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-6692"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-6692"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Stack-based Buffer Overflow vulnerability in libUPnPHndlr.so in Belkin Wemo Insight Smart Plug allows remote attackers to bypass local security protection via a crafted HTTP post packet. Belkin Wemo Insight Smart Plug Contains a buffer error vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. BelkinWemoInsightSmartPlug is a smart plug device from Belkin, USA. A stack buffer overflow vulnerability exists in the libUPnPHndlr.so file in BelkinWemoInsightSmartPlug",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2018-6692"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-009336"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2018-16502"
          },
          {
            "db": "VULHUB",
            "id": "VHN-136724"
          },
          {
            "db": "VULMON",
            "id": "CVE-2018-6692"
          }
        ],
        "trust": 2.34
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2018-6692",
            "trust": 3.2
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-009336",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201808-653",
            "trust": 0.7
          },
          {
            "db": "CNVD",
            "id": "CNVD-2018-16502",
            "trust": 0.6
          },
          {
            "db": "VULHUB",
            "id": "VHN-136724",
            "trust": 0.1
          },
          {
            "db": "VULMON",
            "id": "CVE-2018-6692",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2018-16502"
          },
          {
            "db": "VULHUB",
            "id": "VHN-136724"
          },
          {
            "db": "VULMON",
            "id": "CVE-2018-6692"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-009336"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201808-653"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-6692"
          }
        ]
      },
      "id": "VAR-201808-1010",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2018-16502"
          },
          {
            "db": "VULHUB",
            "id": "VHN-136724"
          }
        ],
        "trust": 1.325
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2018-16502"
          }
        ]
      },
      "last_update_date": "2024-11-23T22:00:19.348000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Wemo Insight Smart Plug",
            "trust": 0.8,
            "url": "https://www.belkin.com/us/p/P-F7C029/"
          },
          {
            "title": "The Register",
            "trust": 0.2,
            "url": "https://www.theregister.co.uk/2018/08/21/mcafee_flaws_smartplugs/"
          },
          {
            "title": "",
            "trust": 0.1,
            "url": "https://github.com/Live-Hack-CVE/CVE-2018-6692 "
          }
        ],
        "sources": [
          {
            "db": "VULMON",
            "id": "CVE-2018-6692"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-009336"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-787",
            "trust": 1.1
          },
          {
            "problemtype": "CWE-119",
            "trust": 0.9
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-136724"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-009336"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-6692"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.6,
            "url": "https://securingtomorrow.mcafee.com/mcafee-labs/insight-into-home-automation-reveals-vulnerability-in-simple-iot-product"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2018-6692"
          },
          {
            "trust": 0.8,
            "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-6692"
          },
          {
            "trust": 0.1,
            "url": "https://cwe.mitre.org/data/definitions/787.html"
          },
          {
            "trust": 0.1,
            "url": "https://github.com/live-hack-cve/cve-2018-6692"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov"
          },
          {
            "trust": 0.1,
            "url": "https://www.theregister.co.uk/2018/08/21/mcafee_flaws_smartplugs/"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2018-16502"
          },
          {
            "db": "VULHUB",
            "id": "VHN-136724"
          },
          {
            "db": "VULMON",
            "id": "CVE-2018-6692"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-009336"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201808-653"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-6692"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2018-16502"
          },
          {
            "db": "VULHUB",
            "id": "VHN-136724"
          },
          {
            "db": "VULMON",
            "id": "CVE-2018-6692"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-009336"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201808-653"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-6692"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2018-08-28T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2018-16502"
          },
          {
            "date": "2018-08-21T00:00:00",
            "db": "VULHUB",
            "id": "VHN-136724"
          },
          {
            "date": "2018-08-21T00:00:00",
            "db": "VULMON",
            "id": "CVE-2018-6692"
          },
          {
            "date": "2018-11-15T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2018-009336"
          },
          {
            "date": "2018-08-22T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201808-653"
          },
          {
            "date": "2018-08-21T14:29:01.750000",
            "db": "NVD",
            "id": "CVE-2018-6692"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2018-08-28T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2018-16502"
          },
          {
            "date": "2023-01-27T00:00:00",
            "db": "VULHUB",
            "id": "VHN-136724"
          },
          {
            "date": "2023-11-07T00:00:00",
            "db": "VULMON",
            "id": "CVE-2018-6692"
          },
          {
            "date": "2018-11-15T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2018-009336"
          },
          {
            "date": "2020-08-25T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201808-653"
          },
          {
            "date": "2024-11-21T04:11:06.717000",
            "db": "NVD",
            "id": "CVE-2018-6692"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201808-653"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Belkin Wemo Insight Smart Plug Buffer error vulnerability",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-009336"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201808-653"
          }
        ],
        "trust": 1.4
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "buffer error",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201808-653"
          }
        ],
        "trust": 0.6
      }
    }

    CVE-2018-6692 (GCVE-0-2018-6692)

    Vulnerability from nvd – Published: 2018-08-21 14:00 – Updated: 2024-08-05 06:10
    VLAI
    Title
    Wemo Insight Smart Plug - Remote Code Execution vulnerability
    Summary
    Stack-based Buffer Overflow vulnerability in libUPnPHndlr.so in Belkin Wemo Insight Smart Plug allows remote attackers to bypass local security protection via a crafted HTTP post packet.
    CWE
    • Stack-based Buffer Overflow vulnerability
    Assigner
    References
    Impacted products
    Vendor Product Version
    Belkin Wemo Insight Smart Plug Affected: WeMo_WW_2.00.11054.PVT-OWRT-Insight , ≤ 2.00.11054 (custom)
    Create a notification for this product.
    Date Public
    2018-08-20 00:00
    Credits
    Doug McKee and the McAfee Advanced Threat Research team.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T06:10:11.342Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://securingtomorrow.mcafee.com/mcafee-labs/insight-into-home-automation-reveals-vulnerability-in-simple-iot-product"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "platforms": [
                "MIPS"
              ],
              "product": "Wemo Insight Smart Plug",
              "vendor": "Belkin",
              "versions": [
                {
                  "lessThanOrEqual": "2.00.11054",
                  "status": "affected",
                  "version": "WeMo_WW_2.00.11054.PVT-OWRT-Insight",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "Doug McKee and the McAfee Advanced Threat Research team."
            }
          ],
          "datePublic": "2018-08-20T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Stack-based Buffer Overflow vulnerability in libUPnPHndlr.so in Belkin Wemo Insight Smart Plug allows remote attackers to bypass local security protection via a crafted HTTP post packet."
            }
          ],
          "metrics": [
            {
              "cvssV3_0": {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 5.9,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:N",
                "version": "3.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Stack-based Buffer Overflow vulnerability",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2018-08-21T13:57:01.000Z",
            "orgId": "01626437-bf8f-4d1c-912a-893b5eb04808",
            "shortName": "trellix"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://securingtomorrow.mcafee.com/mcafee-labs/insight-into-home-automation-reveals-vulnerability-in-simple-iot-product"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "Wemo Insight Smart Plug  - Remote Code Execution vulnerability",
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "psirt@mcafee.com",
              "ID": "CVE-2018-6692",
              "STATE": "PUBLIC",
              "TITLE": "Wemo Insight Smart Plug  - Remote Code Execution vulnerability"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Wemo Insight Smart Plug",
                          "version": {
                            "version_data": [
                              {
                                "affected": "\u003c=",
                                "platform": "MIPS",
                                "version_affected": "\u003c=",
                                "version_name": "WeMo_WW_2.00.11054.PVT-OWRT-Insight",
                                "version_value": "2.00.11054"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Belkin"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "Doug McKee and the McAfee Advanced Threat Research team."
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Stack-based Buffer Overflow vulnerability in libUPnPHndlr.so in Belkin Wemo Insight Smart Plug allows remote attackers to bypass local security protection via a crafted HTTP post packet."
                }
              ]
            },
            "impact": {
              "cvss": {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 5.9,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:N",
                "version": "3.0"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "Stack-based Buffer Overflow vulnerability"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://securingtomorrow.mcafee.com/mcafee-labs/insight-into-home-automation-reveals-vulnerability-in-simple-iot-product",
                  "refsource": "CONFIRM",
                  "url": "https://securingtomorrow.mcafee.com/mcafee-labs/insight-into-home-automation-reveals-vulnerability-in-simple-iot-product"
                }
              ]
            },
            "source": {
              "discovery": "EXTERNAL"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "01626437-bf8f-4d1c-912a-893b5eb04808",
        "assignerShortName": "trellix",
        "cveId": "CVE-2018-6692",
        "datePublished": "2018-08-21T14:00:00.000Z",
        "dateReserved": "2018-02-06T00:00:00.000Z",
        "dateUpdated": "2024-08-05T06:10:11.342Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2018-6692 (GCVE-0-2018-6692)

    Vulnerability from cvelistv5 – Published: 2018-08-21 14:00 – Updated: 2024-08-05 06:10
    VLAI
    Title
    Wemo Insight Smart Plug - Remote Code Execution vulnerability
    Summary
    Stack-based Buffer Overflow vulnerability in libUPnPHndlr.so in Belkin Wemo Insight Smart Plug allows remote attackers to bypass local security protection via a crafted HTTP post packet.
    CWE
    • Stack-based Buffer Overflow vulnerability
    Assigner
    References
    Impacted products
    Vendor Product Version
    Belkin Wemo Insight Smart Plug Affected: WeMo_WW_2.00.11054.PVT-OWRT-Insight , ≤ 2.00.11054 (custom)
    Create a notification for this product.
    Date Public
    2018-08-20 00:00
    Credits
    Doug McKee and the McAfee Advanced Threat Research team.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T06:10:11.342Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://securingtomorrow.mcafee.com/mcafee-labs/insight-into-home-automation-reveals-vulnerability-in-simple-iot-product"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "platforms": [
                "MIPS"
              ],
              "product": "Wemo Insight Smart Plug",
              "vendor": "Belkin",
              "versions": [
                {
                  "lessThanOrEqual": "2.00.11054",
                  "status": "affected",
                  "version": "WeMo_WW_2.00.11054.PVT-OWRT-Insight",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "Doug McKee and the McAfee Advanced Threat Research team."
            }
          ],
          "datePublic": "2018-08-20T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Stack-based Buffer Overflow vulnerability in libUPnPHndlr.so in Belkin Wemo Insight Smart Plug allows remote attackers to bypass local security protection via a crafted HTTP post packet."
            }
          ],
          "metrics": [
            {
              "cvssV3_0": {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 5.9,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:N",
                "version": "3.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Stack-based Buffer Overflow vulnerability",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2018-08-21T13:57:01.000Z",
            "orgId": "01626437-bf8f-4d1c-912a-893b5eb04808",
            "shortName": "trellix"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://securingtomorrow.mcafee.com/mcafee-labs/insight-into-home-automation-reveals-vulnerability-in-simple-iot-product"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "Wemo Insight Smart Plug  - Remote Code Execution vulnerability",
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "psirt@mcafee.com",
              "ID": "CVE-2018-6692",
              "STATE": "PUBLIC",
              "TITLE": "Wemo Insight Smart Plug  - Remote Code Execution vulnerability"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Wemo Insight Smart Plug",
                          "version": {
                            "version_data": [
                              {
                                "affected": "\u003c=",
                                "platform": "MIPS",
                                "version_affected": "\u003c=",
                                "version_name": "WeMo_WW_2.00.11054.PVT-OWRT-Insight",
                                "version_value": "2.00.11054"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Belkin"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "Doug McKee and the McAfee Advanced Threat Research team."
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Stack-based Buffer Overflow vulnerability in libUPnPHndlr.so in Belkin Wemo Insight Smart Plug allows remote attackers to bypass local security protection via a crafted HTTP post packet."
                }
              ]
            },
            "impact": {
              "cvss": {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 5.9,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:N",
                "version": "3.0"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "Stack-based Buffer Overflow vulnerability"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://securingtomorrow.mcafee.com/mcafee-labs/insight-into-home-automation-reveals-vulnerability-in-simple-iot-product",
                  "refsource": "CONFIRM",
                  "url": "https://securingtomorrow.mcafee.com/mcafee-labs/insight-into-home-automation-reveals-vulnerability-in-simple-iot-product"
                }
              ]
            },
            "source": {
              "discovery": "EXTERNAL"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "01626437-bf8f-4d1c-912a-893b5eb04808",
        "assignerShortName": "trellix",
        "cveId": "CVE-2018-6692",
        "datePublished": "2018-08-21T14:00:00.000Z",
        "dateReserved": "2018-02-06T00:00:00.000Z",
        "dateUpdated": "2024-08-05T06:10:11.342Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }