Search

Find a vulnerability

Search criteria

    2 vulnerabilities found for VersiCloud by Siemens

    CVE-2026-111497 (GCVE-0-2026-111497)

    Vulnerability from nvd – Published: 2026-10-22 13:35 – Updated: 2026-10-30 18:31
    VLAI CISA Previdian
    Title
    Out-of-Bounds Write in Google Brotli Decoder
    Summary
    A buffer overflow vulnerability in the Brotli decoder (c/dec/decode.c) in Google Brotli versions 1.0.3 through 1.2.0 on all platforms allows a remote unauthenticated attacker to corrupt adjacent decoder state memory, disclose sensitive memory contents, cause a denial of service, or potentially execute arbitrary code using a crafted Brotli-compressed stream. Users need to update any Brotli libraries or binaries between 1.0.3 through 1.2.0 to the latest available version: 1.0.10 or 1.1.1 or 1.2.1.
    SSVC
    Exploitation: active Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-10-23 00:00 UTC
    CWE
    Assigner
    Google CNA under the Google root
    CNA scorecard B 77/100 over 40 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Google Brotli Affected: 1.0.3 , < 1.0.10 (semver)
    Affected: 1.1.0 , < 1.1.1 (semver)
    Affected: 1.2.0 , < 1.2.1 (semver)
    Create a notification for this product.
    Siemens Heliox Dual Port 60kW Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Heliox Flex Pro Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SICHARGE FLEX Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SICHARGE UC Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Sifinity Go Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Sifinity Setup Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens VersiCharge AC Series Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens VersiCloud Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Cloud Connector Configurator Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Common Configurator (CC on IEM) Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Common Configurator on Device (CC on Edge) Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Data Flow Monitoring Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Databus Configurator Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Edge OPC UA Server Configurator Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Flow Creator Configurator Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Industrial Edge Hub Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Industrial Edge Management Cloud Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens RUGGEDCOM APE1808 Affected: 0 , < * (custom)
    Create a notification for this product.
    Date Public
    2026-02-27 07:50
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-111497",
                    "options": [
                      {
                        "Exploitation": "active"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-10-23T00:00:00+00:00",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-10-28T03:55:48.896Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "references": [
              {
                "tags": [
                  "third-party-advisory"
                ],
                "url": "https://ellio.tech/en/blog/node2shell-cve-2026-111497-rce-on-stock-nodejs-builds/"
              },
              {
                "tags": [
                  "government-resource"
                ],
                "url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2026-111497"
              }
            ],
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2026-10-26T18:10:34.928Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "url": "https://github.com/advisories/GHSA-9v8h-qqgm-4m35"
              },
              {
                "url": "http://www.openwall.com/lists/oss-security/2026/10/23/25"
              },
              {
                "url": "https://lists.debian.org/debian-lts-announce/2026/10/msg00049.html"
              },
              {
                "url": "http://www.openwall.com/lists/oss-security/2026/10/24/6"
              },
              {
                "url": "http://www.openwall.com/lists/oss-security/2026/10/26/12"
              },
              {
                "url": "http://www.openwall.com/lists/oss-security/2026/10/26/13"
              },
              {
                "url": "https://www.aikido.dev/blog/node2shell-nodejs-brotli-rce-cve-2026-111497"
              },
              {
                "url": "https://broccoli2shell.com"
              },
              {
                "url": "https://github.com/dotnet/announcements/issues/494"
              },
              {
                "url": "https://github.com/google/brotli/releases/tag/v1.2.1"
              },
              {
                "url": "https://github.com/google/brotli/releases/tag/v1.1.1"
              },
              {
                "url": "https://github.com/google/brotli/releases/tag/v1.0.10"
              },
              {
                "url": "https://patchtheplanet.org/brotli"
              },
              {
                "url": "http://www.openwall.com/lists/oss-security/2026/10/26/16"
              }
            ],
            "title": "CVE Program Container",
            "x_generator": {
              "engine": "ADPogram 0.0.1"
            }
          },
          {
            "affected": [
              {
                "defaultStatus": "unknown",
                "product": "Heliox Dual Port 60kW",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Heliox Flex Pro",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SICHARGE FLEX",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SICHARGE UC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Sifinity Go",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Sifinity Setup",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "VersiCharge AC Series",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "VersiCloud",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Cloud Connector Configurator",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Common Configurator\u00a0(CC on IEM)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Common Configurator on Device\u00a0(CC on Edge)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Data Flow Monitoring",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Databus Configurator",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Edge OPC UA Server Configurator",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Flow Creator Configurator",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Industrial Edge Hub",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Industrial Edge Management Cloud",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "RUGGEDCOM APE1808",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-10-30T18:31:38.139Z",
              "orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
              "shortName": "siemens-SADP"
            },
            "references": [
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-898633.html"
              },
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-443410.html"
              },
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-045512.html"
              }
            ],
            "x_adpType": "supplier"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "packageName": "github.com/google/brotli",
              "product": "Brotli",
              "repo": "https://github.com/google/brotli",
              "vendor": "Google",
              "versions": [
                {
                  "lessThan": "1.0.10",
                  "status": "affected",
                  "version": "1.0.3",
                  "versionType": "semver"
                },
                {
                  "lessThan": "1.1.1",
                  "status": "affected",
                  "version": "1.1.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "1.2.1",
                  "status": "affected",
                  "version": "1.2.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "OpenAI Codex Security - Khai Tran and Sylvie Mayer"
            }
          ],
          "datePublic": "2026-02-27T07:50:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eA buffer overflow vulnerability in the Brotli decoder (\u003ccode\u003ec/dec/decode.c\u003c/code\u003e) in Google Brotli versions 1.0.3 through 1.2.0 on all platforms allows a remote unauthenticated attacker to corrupt adjacent decoder state memory, disclose sensitive memory contents, cause a denial of service, or potentially execute arbitrary code using a crafted Brotli-compressed stream.\u003cbr\u003e\u003cbr\u003e\u003c/p\u003e\u003cp\u003eUsers need to update any Brotli libraries or binaries between 1.0.3 through 1.2.0 to the latest available version: 1.0.10 or 1.1.1 or 1.2.1.\u003cspan\u003e\u003c/span\u003e\u003c/p\u003e"
                }
              ],
              "value": "A buffer overflow vulnerability in the Brotli decoder (c/dec/decode.c) in Google Brotli versions 1.0.3 through 1.2.0 on all platforms allows a remote unauthenticated attacker to corrupt adjacent decoder state memory, disclose sensitive memory contents, cause a denial of service, or potentially execute arbitrary code using a crafted Brotli-compressed stream.\n\n\n\n\n\nUsers need to update any Brotli libraries or binaries between 1.0.3 through 1.2.0 to the latest available version: 1.0.10 or 1.1.1 or 1.2.1."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-100",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-100 Overflow Buffers"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "PRESENT",
                "attackVector": "NETWORK",
                "baseScore": 9.2,
                "baseSeverity": "CRITICAL",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-787",
                  "description": "CWE-787 Out-of-bounds Write",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-252",
                  "description": "CWE-252 Unchecked Return Value",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-10-27T14:58:42.704Z",
            "orgId": "14ed7db2-1595-443d-9d34-6215bf890778",
            "shortName": "Google"
          },
          "references": [
            {
              "tags": [
                "patch"
              ],
              "url": "https://nodejs.org/en/blog/vulnerability/october-2026-security-releases#nodejs-brotli-decoder-out-of-bounds-write-permits-remote-code-execution-cve-2026-111497---high"
            },
            {
              "tags": [
                "release-notes",
                "third-party-advisory"
              ],
              "url": "https://github.com/andybalholm/brotli/releases/tag/v1.2.7"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Update any Brotli libraries or binaries between 1.0.3 through 1.2.0 to the latest available version: 1.0.10 or 1.1.1 or 1.2.1."
                }
              ],
              "value": "Update any Brotli libraries or binaries between 1.0.3 through 1.2.0 to the latest available version: 1.0.10 or 1.1.1 or 1.2.1."
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "Out-of-Bounds Write in Google Brotli Decoder",
          "x_generator": {
            "engine": "Vulnogram 1.0.2"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "14ed7db2-1595-443d-9d34-6215bf890778",
        "assignerShortName": "Google",
        "cveId": "CVE-2026-111497",
        "datePublished": "2026-10-22T13:35:41.975Z",
        "dateReserved": "2026-10-16T09:58:17.790Z",
        "dateUpdated": "2026-10-30T18:31:38.139Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-111497 (GCVE-0-2026-111497)

    Vulnerability from cvelistv5 – Published: 2026-10-22 13:35 – Updated: 2026-10-30 18:31
    VLAI CISA Previdian
    Title
    Out-of-Bounds Write in Google Brotli Decoder
    Summary
    A buffer overflow vulnerability in the Brotli decoder (c/dec/decode.c) in Google Brotli versions 1.0.3 through 1.2.0 on all platforms allows a remote unauthenticated attacker to corrupt adjacent decoder state memory, disclose sensitive memory contents, cause a denial of service, or potentially execute arbitrary code using a crafted Brotli-compressed stream. Users need to update any Brotli libraries or binaries between 1.0.3 through 1.2.0 to the latest available version: 1.0.10 or 1.1.1 or 1.2.1.
    SSVC
    Exploitation: active Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-10-23 00:00 UTC
    CWE
    Assigner
    Google CNA under the Google root
    CNA scorecard B 77/100 over 40 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Google Brotli Affected: 1.0.3 , < 1.0.10 (semver)
    Affected: 1.1.0 , < 1.1.1 (semver)
    Affected: 1.2.0 , < 1.2.1 (semver)
    Create a notification for this product.
    Siemens Heliox Dual Port 60kW Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Heliox Flex Pro Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SICHARGE FLEX Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SICHARGE UC Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Sifinity Go Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Sifinity Setup Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens VersiCharge AC Series Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens VersiCloud Unaffected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Cloud Connector Configurator Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Common Configurator (CC on IEM) Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Common Configurator on Device (CC on Edge) Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Data Flow Monitoring Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Databus Configurator Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Edge OPC UA Server Configurator Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Flow Creator Configurator Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Industrial Edge Hub Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens Industrial Edge Management Cloud Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens RUGGEDCOM APE1808 Affected: 0 , < * (custom)
    Create a notification for this product.
    Date Public
    2026-02-27 07:50
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-111497",
                    "options": [
                      {
                        "Exploitation": "active"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-10-23T00:00:00+00:00",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-10-28T03:55:48.896Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "references": [
              {
                "tags": [
                  "third-party-advisory"
                ],
                "url": "https://ellio.tech/en/blog/node2shell-cve-2026-111497-rce-on-stock-nodejs-builds/"
              },
              {
                "tags": [
                  "government-resource"
                ],
                "url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2026-111497"
              }
            ],
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2026-10-26T18:10:34.928Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "url": "https://github.com/advisories/GHSA-9v8h-qqgm-4m35"
              },
              {
                "url": "http://www.openwall.com/lists/oss-security/2026/10/23/25"
              },
              {
                "url": "https://lists.debian.org/debian-lts-announce/2026/10/msg00049.html"
              },
              {
                "url": "http://www.openwall.com/lists/oss-security/2026/10/24/6"
              },
              {
                "url": "http://www.openwall.com/lists/oss-security/2026/10/26/12"
              },
              {
                "url": "http://www.openwall.com/lists/oss-security/2026/10/26/13"
              },
              {
                "url": "https://www.aikido.dev/blog/node2shell-nodejs-brotli-rce-cve-2026-111497"
              },
              {
                "url": "https://broccoli2shell.com"
              },
              {
                "url": "https://github.com/dotnet/announcements/issues/494"
              },
              {
                "url": "https://github.com/google/brotli/releases/tag/v1.2.1"
              },
              {
                "url": "https://github.com/google/brotli/releases/tag/v1.1.1"
              },
              {
                "url": "https://github.com/google/brotli/releases/tag/v1.0.10"
              },
              {
                "url": "https://patchtheplanet.org/brotli"
              },
              {
                "url": "http://www.openwall.com/lists/oss-security/2026/10/26/16"
              }
            ],
            "title": "CVE Program Container",
            "x_generator": {
              "engine": "ADPogram 0.0.1"
            }
          },
          {
            "affected": [
              {
                "defaultStatus": "unknown",
                "product": "Heliox Dual Port 60kW",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Heliox Flex Pro",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SICHARGE FLEX",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SICHARGE UC",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Sifinity Go",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Sifinity Setup",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "VersiCharge AC Series",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "VersiCloud",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "unaffected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Cloud Connector Configurator",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Common Configurator\u00a0(CC on IEM)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Common Configurator on Device\u00a0(CC on Edge)",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Data Flow Monitoring",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Databus Configurator",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Edge OPC UA Server Configurator",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Flow Creator Configurator",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Industrial Edge Hub",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "Industrial Edge Management Cloud",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "RUGGEDCOM APE1808",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-10-30T18:31:38.139Z",
              "orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
              "shortName": "siemens-SADP"
            },
            "references": [
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-898633.html"
              },
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-443410.html"
              },
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-045512.html"
              }
            ],
            "x_adpType": "supplier"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "packageName": "github.com/google/brotli",
              "product": "Brotli",
              "repo": "https://github.com/google/brotli",
              "vendor": "Google",
              "versions": [
                {
                  "lessThan": "1.0.10",
                  "status": "affected",
                  "version": "1.0.3",
                  "versionType": "semver"
                },
                {
                  "lessThan": "1.1.1",
                  "status": "affected",
                  "version": "1.1.0",
                  "versionType": "semver"
                },
                {
                  "lessThan": "1.2.1",
                  "status": "affected",
                  "version": "1.2.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "OpenAI Codex Security - Khai Tran and Sylvie Mayer"
            }
          ],
          "datePublic": "2026-02-27T07:50:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eA buffer overflow vulnerability in the Brotli decoder (\u003ccode\u003ec/dec/decode.c\u003c/code\u003e) in Google Brotli versions 1.0.3 through 1.2.0 on all platforms allows a remote unauthenticated attacker to corrupt adjacent decoder state memory, disclose sensitive memory contents, cause a denial of service, or potentially execute arbitrary code using a crafted Brotli-compressed stream.\u003cbr\u003e\u003cbr\u003e\u003c/p\u003e\u003cp\u003eUsers need to update any Brotli libraries or binaries between 1.0.3 through 1.2.0 to the latest available version: 1.0.10 or 1.1.1 or 1.2.1.\u003cspan\u003e\u003c/span\u003e\u003c/p\u003e"
                }
              ],
              "value": "A buffer overflow vulnerability in the Brotli decoder (c/dec/decode.c) in Google Brotli versions 1.0.3 through 1.2.0 on all platforms allows a remote unauthenticated attacker to corrupt adjacent decoder state memory, disclose sensitive memory contents, cause a denial of service, or potentially execute arbitrary code using a crafted Brotli-compressed stream.\n\n\n\n\n\nUsers need to update any Brotli libraries or binaries between 1.0.3 through 1.2.0 to the latest available version: 1.0.10 or 1.1.1 or 1.2.1."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-100",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-100 Overflow Buffers"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "PRESENT",
                "attackVector": "NETWORK",
                "baseScore": 9.2,
                "baseSeverity": "CRITICAL",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-787",
                  "description": "CWE-787 Out-of-bounds Write",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-252",
                  "description": "CWE-252 Unchecked Return Value",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-10-27T14:58:42.704Z",
            "orgId": "14ed7db2-1595-443d-9d34-6215bf890778",
            "shortName": "Google"
          },
          "references": [
            {
              "tags": [
                "patch"
              ],
              "url": "https://nodejs.org/en/blog/vulnerability/october-2026-security-releases#nodejs-brotli-decoder-out-of-bounds-write-permits-remote-code-execution-cve-2026-111497---high"
            },
            {
              "tags": [
                "release-notes",
                "third-party-advisory"
              ],
              "url": "https://github.com/andybalholm/brotli/releases/tag/v1.2.7"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Update any Brotli libraries or binaries between 1.0.3 through 1.2.0 to the latest available version: 1.0.10 or 1.1.1 or 1.2.1."
                }
              ],
              "value": "Update any Brotli libraries or binaries between 1.0.3 through 1.2.0 to the latest available version: 1.0.10 or 1.1.1 or 1.2.1."
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "Out-of-Bounds Write in Google Brotli Decoder",
          "x_generator": {
            "engine": "Vulnogram 1.0.2"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "14ed7db2-1595-443d-9d34-6215bf890778",
        "assignerShortName": "Google",
        "cveId": "CVE-2026-111497",
        "datePublished": "2026-10-22T13:35:41.975Z",
        "dateReserved": "2026-10-16T09:58:17.790Z",
        "dateUpdated": "2026-10-30T18:31:38.139Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }