Search

Find a vulnerability

Search criteria

    8 vulnerabilities found for Unitronics UniStream Pro/UniLogic by Unitronics

    CVE-2026-45452 (GCVE-0-2026-45452)

    Vulnerability from nvd – Published: 2026-10-15 15:25 – Updated: 2026-10-15 17:59
    VLAI
    Title
    Unitronics - CWE-134 Use of Externally-Controlled format string
    Summary
    Use of Externally-Controlled format string vulnerability in Unitronics Unitronics UniStream Pro/UniLogic. This issue affects Unitronics UniStream Pro/UniLogic: Unitronics UniStream Pro versions only (B10 / C10) – UniLogic versions prior to 1.41.329.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-10-15 17:58 UTC
    CWE
    • CWE-134 - Use of Externally-Controlled format string
    Assigner
    INCD CNA under the mitre root
    CNA scorecard C 69/100 over 17 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Unitronics Unitronics UniStream Pro/UniLogic Affected: Unitronics UniStream Pro versions only (B10 / C10) – UniLogic versions prior to 1.41.329
    Create a notification for this product.
    Date Public
    2026-10-15 15:13
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-45452",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-10-15T17:58:47.636535Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-10-15T17:59:46.210Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Unitronics UniStream Pro/UniLogic",
              "vendor": "Unitronics",
              "versions": [
                {
                  "status": "affected",
                  "version": "Unitronics UniStream Pro versions only (B10 / C10) \u2013 UniLogic versions prior to 1.41.329"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "SemanticGuard"
            }
          ],
          "datePublic": "2026-10-15T15:13:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Use of Externally-Controlled format string vulnerability in Unitronics Unitronics UniStream Pro/UniLogic.\u003cp\u003eThis issue affects Unitronics UniStream Pro/UniLogic: Unitronics UniStream Pro versions only (B10 / C10) \u2013 UniLogic versions prior to 1.41.329.\u003c/p\u003e"
                }
              ],
              "value": "Use of Externally-Controlled format string vulnerability in Unitronics Unitronics UniStream Pro/UniLogic.\n\nThis issue affects Unitronics UniStream Pro/UniLogic: Unitronics UniStream Pro versions only (B10 / C10) \u2013 UniLogic versions prior to 1.41.329."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "LOW",
                "baseScore": 8.3,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:L",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-134",
                  "description": "CWE-134 Use of Externally-Controlled format string",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-10-15T15:25:54.445Z",
            "orgId": "a57ee1ae-c9c1-4f40-aa7b-cf10760fde3f",
            "shortName": "INCD"
          },
          "references": [
            {
              "url": "https://www.gov.il/en/departments/dynamiccollectors/cve_advisories_listing?skip=0"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003ctable\u003e\n \n \u003ctbody\u003e\u003ctr\u003e\n\n  \u003ctd\u003e\u003ctable\u003e\n \n \u003ctbody\u003e\u003ctr\u003e\n\n  \u003ctd\u003eUpgrade UniLogic and UniStream to version 1.42.220 or above\u003c/td\u003e\n\n \u003c/tr\u003e\n\u003c/tbody\u003e\u003c/table\u003e\u003c/td\u003e\u003c/tr\u003e\u003c/tbody\u003e\u003c/table\u003e"
                }
              ],
              "value": "Upgrade UniLogic and UniStream to version 1.42.220 or above"
            }
          ],
          "source": {
            "advisory": "ILVN-2025-0264",
            "discovery": "UNKNOWN"
          },
          "title": "Unitronics - CWE-134 Use of Externally-Controlled format string",
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "a57ee1ae-c9c1-4f40-aa7b-cf10760fde3f",
        "assignerShortName": "INCD",
        "cveId": "CVE-2026-45452",
        "datePublished": "2026-10-15T15:25:54.445Z",
        "dateReserved": "2026-05-12T15:11:23.921Z",
        "dateUpdated": "2026-10-15T17:59:46.210Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-45451 (GCVE-0-2026-45451)

    Vulnerability from nvd – Published: 2026-10-15 15:23 – Updated: 2026-10-15 18:00
    VLAI
    Title
    Unitronics - CWE-287: Improper Authentication
    Summary
    : Improper Authentication vulnerability in Unitronics Unitronics UniStream Pro/UniLogic. This issue affects Unitronics UniStream Pro/UniLogic: Unitronics UniStream Pro versions only (B10 / C10) – UniLogic versions prior to 1.41.329.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-10-15 18:00 UTC
    CWE
    • CWE-287 - Improper Authentication
    Assigner
    INCD CNA under the mitre root
    CNA scorecard C 69/100 over 17 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Unitronics Unitronics UniStream Pro/UniLogic Affected: Unitronics UniStream Pro versions only (B10 / C10) – UniLogic versions prior to 1.41.329
    Create a notification for this product.
    Date Public
    2026-10-15 15:13
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-45451",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-10-15T18:00:17.370132Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-10-15T18:00:27.448Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Unitronics UniStream Pro/UniLogic",
              "vendor": "Unitronics",
              "versions": [
                {
                  "status": "affected",
                  "version": "Unitronics UniStream Pro versions only (B10 / C10) \u2013 UniLogic versions prior to 1.41.329"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "SemanticGuard"
            }
          ],
          "datePublic": "2026-10-15T15:13:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": ": Improper Authentication vulnerability in Unitronics Unitronics UniStream Pro/UniLogic.\u003cp\u003eThis issue affects Unitronics UniStream Pro/UniLogic: Unitronics UniStream Pro versions only (B10 / C10) \u2013 UniLogic versions prior to 1.41.329.\u003c/p\u003e"
                }
              ],
              "value": ": Improper Authentication vulnerability in Unitronics Unitronics UniStream Pro/UniLogic.\n\nThis issue affects Unitronics UniStream Pro/UniLogic: Unitronics UniStream Pro versions only (B10 / C10) \u2013 UniLogic versions prior to 1.41.329."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "LOW",
                "baseScore": 8.3,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:L",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-287",
                  "description": "CWE-287: Improper Authentication",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-10-15T15:23:55.464Z",
            "orgId": "a57ee1ae-c9c1-4f40-aa7b-cf10760fde3f",
            "shortName": "INCD"
          },
          "references": [
            {
              "url": "https://www.gov.il/en/departments/dynamiccollectors/cve_advisories_listing?skip=0"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003ctable\u003e\n \n \u003ctbody\u003e\u003ctr\u003e\n\n  \u003ctd\u003e\u003ctable\u003e\n \n \u003ctbody\u003e\u003ctr\u003e\n\n  \u003ctd\u003eUpgrade UniLogic and UniStream to version 1.42.220 or above\u003c/td\u003e\n\n \u003c/tr\u003e\n\u003c/tbody\u003e\u003c/table\u003e\u003c/td\u003e\u003c/tr\u003e\u003c/tbody\u003e\u003c/table\u003e"
                }
              ],
              "value": "Upgrade UniLogic and UniStream to version 1.42.220 or above"
            }
          ],
          "source": {
            "advisory": "ILVN-2025-0263",
            "discovery": "UNKNOWN"
          },
          "title": "Unitronics - CWE-287: Improper Authentication",
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "a57ee1ae-c9c1-4f40-aa7b-cf10760fde3f",
        "assignerShortName": "INCD",
        "cveId": "CVE-2026-45451",
        "datePublished": "2026-10-15T15:23:55.464Z",
        "dateReserved": "2026-05-12T15:11:23.921Z",
        "dateUpdated": "2026-10-15T18:00:27.448Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-45450 (GCVE-0-2026-45450)

    Vulnerability from nvd – Published: 2026-10-15 15:21 – Updated: 2026-10-15 18:01
    VLAI
    Title
    Unitronics - CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer
    Summary
    : Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability in Unitronics Unitronics UniStream Pro/UniLogic. This issue affects Unitronics UniStream Pro/UniLogic: Unitronics UniStream Pro versions only (B10 / C10) – UniLogic versions prior to 1.41.329.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-10-15 18:00 UTC
    CWE
    • CWE-119 - Improper Restriction of Operations within the Bounds of a Memory Buffer
    Assigner
    INCD CNA under the mitre root
    CNA scorecard C 69/100 over 17 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Unitronics Unitronics UniStream Pro/UniLogic Affected: Unitronics UniStream Pro versions only (B10 / C10) – UniLogic versions prior to 1.41.329
    Create a notification for this product.
    Date Public
    2026-10-15 15:13
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-45450",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-10-15T18:00:51.546802Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-10-15T18:01:17.303Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Unitronics UniStream Pro/UniLogic",
              "vendor": "Unitronics",
              "versions": [
                {
                  "status": "affected",
                  "version": "Unitronics UniStream Pro versions only (B10 / C10) \u2013 UniLogic versions prior to 1.41.329"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "SemanticGuard"
            }
          ],
          "datePublic": "2026-10-15T15:13:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": ": Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability in Unitronics Unitronics UniStream Pro/UniLogic.\u003cp\u003eThis issue affects Unitronics UniStream Pro/UniLogic: Unitronics UniStream Pro versions only (B10 / C10) \u2013 UniLogic versions prior to 1.41.329.\u003c/p\u003e"
                }
              ],
              "value": ": Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability in Unitronics Unitronics UniStream Pro/UniLogic.\n\nThis issue affects Unitronics UniStream Pro/UniLogic: Unitronics UniStream Pro versions only (B10 / C10) \u2013 UniLogic versions prior to 1.41.329."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "LOW",
                "baseScore": 8.3,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:L",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-10-15T15:21:41.203Z",
            "orgId": "a57ee1ae-c9c1-4f40-aa7b-cf10760fde3f",
            "shortName": "INCD"
          },
          "references": [
            {
              "url": "https://www.gov.il/en/departments/dynamiccollectors/cve_advisories_listing?skip=0"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003ctable\u003e\n \n \u003ctbody\u003e\u003ctr\u003e\n\n  \u003ctd\u003e\u003ctable\u003e\n \n \u003ctbody\u003e\u003ctr\u003e\n\n  \u003ctd\u003eUpgrade UniLogic and UniStream to version 1.42.220 or above\u003c/td\u003e\n\n \u003c/tr\u003e\n\u003c/tbody\u003e\u003c/table\u003e\u003c/td\u003e\u003c/tr\u003e\u003c/tbody\u003e\u003c/table\u003e"
                }
              ],
              "value": "Upgrade UniLogic and UniStream to version 1.42.220 or above"
            }
          ],
          "source": {
            "advisory": "ILVN-2025-0262",
            "discovery": "UNKNOWN"
          },
          "title": "Unitronics - CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer",
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "a57ee1ae-c9c1-4f40-aa7b-cf10760fde3f",
        "assignerShortName": "INCD",
        "cveId": "CVE-2026-45450",
        "datePublished": "2026-10-15T15:21:41.203Z",
        "dateReserved": "2026-05-12T15:11:23.921Z",
        "dateUpdated": "2026-10-15T18:01:17.303Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-45449 (GCVE-0-2026-45449)

    Vulnerability from nvd – Published: 2026-10-15 15:18 – Updated: 2026-10-15 18:06
    VLAI
    Title
    Unitronics - CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    Summary
    : Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in Unitronics Unitronics UniStream Pro/UniLogic. This issue affects Unitronics UniStream Pro/UniLogic: Unitronics UniStream Pro versions only (B10 / C10) – UniLogic versions prior to 1.41.329.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-10-15 18:05 UTC
    CWE
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    Assigner
    INCD CNA under the mitre root
    CNA scorecard C 69/100 over 17 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Unitronics Unitronics UniStream Pro/UniLogic Affected: Unitronics UniStream Pro versions only (B10 / C10) – UniLogic versions prior to 1.41.329
    Create a notification for this product.
    Date Public
    2026-10-15 15:13
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-45449",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-10-15T18:05:49.669716Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-10-15T18:06:03.223Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Unitronics UniStream Pro/UniLogic",
              "vendor": "Unitronics",
              "versions": [
                {
                  "status": "affected",
                  "version": "Unitronics UniStream Pro versions only (B10 / C10) \u2013 UniLogic versions prior to 1.41.329"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "SemanticGuard"
            }
          ],
          "datePublic": "2026-10-15T15:13:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": ": Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) vulnerability in Unitronics Unitronics UniStream Pro/UniLogic.\u003cp\u003eThis issue affects Unitronics UniStream Pro/UniLogic: Unitronics UniStream Pro versions only (B10 / C10) \u2013 UniLogic versions prior to 1.41.329.\u003c/p\u003e"
                }
              ],
              "value": ": Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) vulnerability in Unitronics Unitronics UniStream Pro/UniLogic.\n\nThis issue affects Unitronics UniStream Pro/UniLogic: Unitronics UniStream Pro versions only (B10 / C10) \u2013 UniLogic versions prior to 1.41.329."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "LOW",
                "baseScore": 8.3,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:L",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-10-15T15:18:59.438Z",
            "orgId": "a57ee1ae-c9c1-4f40-aa7b-cf10760fde3f",
            "shortName": "INCD"
          },
          "references": [
            {
              "url": "https://www.gov.il/en/departments/dynamiccollectors/cve_advisories_listing?skip=0"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003ctable\u003e\n \n \u003ctbody\u003e\u003ctr\u003e\n\n  \u003ctd\u003eUpgrade UniLogic and UniStream to version 1.41.329 or above\u003c/td\u003e\n\n \u003c/tr\u003e\n\u003c/tbody\u003e\u003c/table\u003e"
                }
              ],
              "value": "Upgrade UniLogic and UniStream to version 1.41.329 or above"
            }
          ],
          "source": {
            "advisory": "ILVN-2025-0261",
            "discovery": "UNKNOWN"
          },
          "title": "Unitronics - CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "a57ee1ae-c9c1-4f40-aa7b-cf10760fde3f",
        "assignerShortName": "INCD",
        "cveId": "CVE-2026-45449",
        "datePublished": "2026-10-15T15:18:59.438Z",
        "dateReserved": "2026-05-12T15:11:23.921Z",
        "dateUpdated": "2026-10-15T18:06:03.223Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-45452 (GCVE-0-2026-45452)

    Vulnerability from cvelistv5 – Published: 2026-10-15 15:25 – Updated: 2026-10-15 17:59
    VLAI
    Title
    Unitronics - CWE-134 Use of Externally-Controlled format string
    Summary
    Use of Externally-Controlled format string vulnerability in Unitronics Unitronics UniStream Pro/UniLogic. This issue affects Unitronics UniStream Pro/UniLogic: Unitronics UniStream Pro versions only (B10 / C10) – UniLogic versions prior to 1.41.329.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-10-15 17:58 UTC
    CWE
    • CWE-134 - Use of Externally-Controlled format string
    Assigner
    INCD CNA under the mitre root
    CNA scorecard C 69/100 over 17 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Unitronics Unitronics UniStream Pro/UniLogic Affected: Unitronics UniStream Pro versions only (B10 / C10) – UniLogic versions prior to 1.41.329
    Create a notification for this product.
    Date Public
    2026-10-15 15:13
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-45452",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-10-15T17:58:47.636535Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-10-15T17:59:46.210Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Unitronics UniStream Pro/UniLogic",
              "vendor": "Unitronics",
              "versions": [
                {
                  "status": "affected",
                  "version": "Unitronics UniStream Pro versions only (B10 / C10) \u2013 UniLogic versions prior to 1.41.329"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "SemanticGuard"
            }
          ],
          "datePublic": "2026-10-15T15:13:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Use of Externally-Controlled format string vulnerability in Unitronics Unitronics UniStream Pro/UniLogic.\u003cp\u003eThis issue affects Unitronics UniStream Pro/UniLogic: Unitronics UniStream Pro versions only (B10 / C10) \u2013 UniLogic versions prior to 1.41.329.\u003c/p\u003e"
                }
              ],
              "value": "Use of Externally-Controlled format string vulnerability in Unitronics Unitronics UniStream Pro/UniLogic.\n\nThis issue affects Unitronics UniStream Pro/UniLogic: Unitronics UniStream Pro versions only (B10 / C10) \u2013 UniLogic versions prior to 1.41.329."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "LOW",
                "baseScore": 8.3,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:L",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-134",
                  "description": "CWE-134 Use of Externally-Controlled format string",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-10-15T15:25:54.445Z",
            "orgId": "a57ee1ae-c9c1-4f40-aa7b-cf10760fde3f",
            "shortName": "INCD"
          },
          "references": [
            {
              "url": "https://www.gov.il/en/departments/dynamiccollectors/cve_advisories_listing?skip=0"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003ctable\u003e\n \n \u003ctbody\u003e\u003ctr\u003e\n\n  \u003ctd\u003e\u003ctable\u003e\n \n \u003ctbody\u003e\u003ctr\u003e\n\n  \u003ctd\u003eUpgrade UniLogic and UniStream to version 1.42.220 or above\u003c/td\u003e\n\n \u003c/tr\u003e\n\u003c/tbody\u003e\u003c/table\u003e\u003c/td\u003e\u003c/tr\u003e\u003c/tbody\u003e\u003c/table\u003e"
                }
              ],
              "value": "Upgrade UniLogic and UniStream to version 1.42.220 or above"
            }
          ],
          "source": {
            "advisory": "ILVN-2025-0264",
            "discovery": "UNKNOWN"
          },
          "title": "Unitronics - CWE-134 Use of Externally-Controlled format string",
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "a57ee1ae-c9c1-4f40-aa7b-cf10760fde3f",
        "assignerShortName": "INCD",
        "cveId": "CVE-2026-45452",
        "datePublished": "2026-10-15T15:25:54.445Z",
        "dateReserved": "2026-05-12T15:11:23.921Z",
        "dateUpdated": "2026-10-15T17:59:46.210Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-45451 (GCVE-0-2026-45451)

    Vulnerability from cvelistv5 – Published: 2026-10-15 15:23 – Updated: 2026-10-15 18:00
    VLAI
    Title
    Unitronics - CWE-287: Improper Authentication
    Summary
    : Improper Authentication vulnerability in Unitronics Unitronics UniStream Pro/UniLogic. This issue affects Unitronics UniStream Pro/UniLogic: Unitronics UniStream Pro versions only (B10 / C10) – UniLogic versions prior to 1.41.329.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-10-15 18:00 UTC
    CWE
    • CWE-287 - Improper Authentication
    Assigner
    INCD CNA under the mitre root
    CNA scorecard C 69/100 over 17 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Unitronics Unitronics UniStream Pro/UniLogic Affected: Unitronics UniStream Pro versions only (B10 / C10) – UniLogic versions prior to 1.41.329
    Create a notification for this product.
    Date Public
    2026-10-15 15:13
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-45451",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-10-15T18:00:17.370132Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-10-15T18:00:27.448Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Unitronics UniStream Pro/UniLogic",
              "vendor": "Unitronics",
              "versions": [
                {
                  "status": "affected",
                  "version": "Unitronics UniStream Pro versions only (B10 / C10) \u2013 UniLogic versions prior to 1.41.329"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "SemanticGuard"
            }
          ],
          "datePublic": "2026-10-15T15:13:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": ": Improper Authentication vulnerability in Unitronics Unitronics UniStream Pro/UniLogic.\u003cp\u003eThis issue affects Unitronics UniStream Pro/UniLogic: Unitronics UniStream Pro versions only (B10 / C10) \u2013 UniLogic versions prior to 1.41.329.\u003c/p\u003e"
                }
              ],
              "value": ": Improper Authentication vulnerability in Unitronics Unitronics UniStream Pro/UniLogic.\n\nThis issue affects Unitronics UniStream Pro/UniLogic: Unitronics UniStream Pro versions only (B10 / C10) \u2013 UniLogic versions prior to 1.41.329."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "LOW",
                "baseScore": 8.3,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:L",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-287",
                  "description": "CWE-287: Improper Authentication",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-10-15T15:23:55.464Z",
            "orgId": "a57ee1ae-c9c1-4f40-aa7b-cf10760fde3f",
            "shortName": "INCD"
          },
          "references": [
            {
              "url": "https://www.gov.il/en/departments/dynamiccollectors/cve_advisories_listing?skip=0"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003ctable\u003e\n \n \u003ctbody\u003e\u003ctr\u003e\n\n  \u003ctd\u003e\u003ctable\u003e\n \n \u003ctbody\u003e\u003ctr\u003e\n\n  \u003ctd\u003eUpgrade UniLogic and UniStream to version 1.42.220 or above\u003c/td\u003e\n\n \u003c/tr\u003e\n\u003c/tbody\u003e\u003c/table\u003e\u003c/td\u003e\u003c/tr\u003e\u003c/tbody\u003e\u003c/table\u003e"
                }
              ],
              "value": "Upgrade UniLogic and UniStream to version 1.42.220 or above"
            }
          ],
          "source": {
            "advisory": "ILVN-2025-0263",
            "discovery": "UNKNOWN"
          },
          "title": "Unitronics - CWE-287: Improper Authentication",
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "a57ee1ae-c9c1-4f40-aa7b-cf10760fde3f",
        "assignerShortName": "INCD",
        "cveId": "CVE-2026-45451",
        "datePublished": "2026-10-15T15:23:55.464Z",
        "dateReserved": "2026-05-12T15:11:23.921Z",
        "dateUpdated": "2026-10-15T18:00:27.448Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-45450 (GCVE-0-2026-45450)

    Vulnerability from cvelistv5 – Published: 2026-10-15 15:21 – Updated: 2026-10-15 18:01
    VLAI
    Title
    Unitronics - CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer
    Summary
    : Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability in Unitronics Unitronics UniStream Pro/UniLogic. This issue affects Unitronics UniStream Pro/UniLogic: Unitronics UniStream Pro versions only (B10 / C10) – UniLogic versions prior to 1.41.329.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-10-15 18:00 UTC
    CWE
    • CWE-119 - Improper Restriction of Operations within the Bounds of a Memory Buffer
    Assigner
    INCD CNA under the mitre root
    CNA scorecard C 69/100 over 17 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Unitronics Unitronics UniStream Pro/UniLogic Affected: Unitronics UniStream Pro versions only (B10 / C10) – UniLogic versions prior to 1.41.329
    Create a notification for this product.
    Date Public
    2026-10-15 15:13
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-45450",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-10-15T18:00:51.546802Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-10-15T18:01:17.303Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Unitronics UniStream Pro/UniLogic",
              "vendor": "Unitronics",
              "versions": [
                {
                  "status": "affected",
                  "version": "Unitronics UniStream Pro versions only (B10 / C10) \u2013 UniLogic versions prior to 1.41.329"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "SemanticGuard"
            }
          ],
          "datePublic": "2026-10-15T15:13:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": ": Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability in Unitronics Unitronics UniStream Pro/UniLogic.\u003cp\u003eThis issue affects Unitronics UniStream Pro/UniLogic: Unitronics UniStream Pro versions only (B10 / C10) \u2013 UniLogic versions prior to 1.41.329.\u003c/p\u003e"
                }
              ],
              "value": ": Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability in Unitronics Unitronics UniStream Pro/UniLogic.\n\nThis issue affects Unitronics UniStream Pro/UniLogic: Unitronics UniStream Pro versions only (B10 / C10) \u2013 UniLogic versions prior to 1.41.329."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "LOW",
                "baseScore": 8.3,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:L",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-10-15T15:21:41.203Z",
            "orgId": "a57ee1ae-c9c1-4f40-aa7b-cf10760fde3f",
            "shortName": "INCD"
          },
          "references": [
            {
              "url": "https://www.gov.il/en/departments/dynamiccollectors/cve_advisories_listing?skip=0"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003ctable\u003e\n \n \u003ctbody\u003e\u003ctr\u003e\n\n  \u003ctd\u003e\u003ctable\u003e\n \n \u003ctbody\u003e\u003ctr\u003e\n\n  \u003ctd\u003eUpgrade UniLogic and UniStream to version 1.42.220 or above\u003c/td\u003e\n\n \u003c/tr\u003e\n\u003c/tbody\u003e\u003c/table\u003e\u003c/td\u003e\u003c/tr\u003e\u003c/tbody\u003e\u003c/table\u003e"
                }
              ],
              "value": "Upgrade UniLogic and UniStream to version 1.42.220 or above"
            }
          ],
          "source": {
            "advisory": "ILVN-2025-0262",
            "discovery": "UNKNOWN"
          },
          "title": "Unitronics - CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer",
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "a57ee1ae-c9c1-4f40-aa7b-cf10760fde3f",
        "assignerShortName": "INCD",
        "cveId": "CVE-2026-45450",
        "datePublished": "2026-10-15T15:21:41.203Z",
        "dateReserved": "2026-05-12T15:11:23.921Z",
        "dateUpdated": "2026-10-15T18:01:17.303Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-45449 (GCVE-0-2026-45449)

    Vulnerability from cvelistv5 – Published: 2026-10-15 15:18 – Updated: 2026-10-15 18:06
    VLAI
    Title
    Unitronics - CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    Summary
    : Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in Unitronics Unitronics UniStream Pro/UniLogic. This issue affects Unitronics UniStream Pro/UniLogic: Unitronics UniStream Pro versions only (B10 / C10) – UniLogic versions prior to 1.41.329.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-10-15 18:05 UTC
    CWE
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    Assigner
    INCD CNA under the mitre root
    CNA scorecard C 69/100 over 17 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Unitronics Unitronics UniStream Pro/UniLogic Affected: Unitronics UniStream Pro versions only (B10 / C10) – UniLogic versions prior to 1.41.329
    Create a notification for this product.
    Date Public
    2026-10-15 15:13
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-45449",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-10-15T18:05:49.669716Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-10-15T18:06:03.223Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Unitronics UniStream Pro/UniLogic",
              "vendor": "Unitronics",
              "versions": [
                {
                  "status": "affected",
                  "version": "Unitronics UniStream Pro versions only (B10 / C10) \u2013 UniLogic versions prior to 1.41.329"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "SemanticGuard"
            }
          ],
          "datePublic": "2026-10-15T15:13:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": ": Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) vulnerability in Unitronics Unitronics UniStream Pro/UniLogic.\u003cp\u003eThis issue affects Unitronics UniStream Pro/UniLogic: Unitronics UniStream Pro versions only (B10 / C10) \u2013 UniLogic versions prior to 1.41.329.\u003c/p\u003e"
                }
              ],
              "value": ": Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027) vulnerability in Unitronics Unitronics UniStream Pro/UniLogic.\n\nThis issue affects Unitronics UniStream Pro/UniLogic: Unitronics UniStream Pro versions only (B10 / C10) \u2013 UniLogic versions prior to 1.41.329."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "LOW",
                "baseScore": 8.3,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:L",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-10-15T15:18:59.438Z",
            "orgId": "a57ee1ae-c9c1-4f40-aa7b-cf10760fde3f",
            "shortName": "INCD"
          },
          "references": [
            {
              "url": "https://www.gov.il/en/departments/dynamiccollectors/cve_advisories_listing?skip=0"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003ctable\u003e\n \n \u003ctbody\u003e\u003ctr\u003e\n\n  \u003ctd\u003eUpgrade UniLogic and UniStream to version 1.41.329 or above\u003c/td\u003e\n\n \u003c/tr\u003e\n\u003c/tbody\u003e\u003c/table\u003e"
                }
              ],
              "value": "Upgrade UniLogic and UniStream to version 1.41.329 or above"
            }
          ],
          "source": {
            "advisory": "ILVN-2025-0261",
            "discovery": "UNKNOWN"
          },
          "title": "Unitronics - CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "a57ee1ae-c9c1-4f40-aa7b-cf10760fde3f",
        "assignerShortName": "INCD",
        "cveId": "CVE-2026-45449",
        "datePublished": "2026-10-15T15:18:59.438Z",
        "dateReserved": "2026-05-12T15:11:23.921Z",
        "dateUpdated": "2026-10-15T18:06:03.223Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }