    CVE-2022-2323 (GCVE-0-2022-2323)

    Vulnerability from nvd – Published: 2022-07-29 19:15 – Updated: 2024-08-03 00:32
    VLAI
    Summary
    Improper neutralization of special elements used in a user input allows an authenticated malicious user to perform remote code execution in the host system. This vulnerability impacts SonicWall Switch 1.1.1.0-2s and earlier versions
    Severity
    No CVSS data available.
    CWE
    • CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
    Assigner
    References
    Impacted products
    Vendor Product Version
    SonicWall SonicWall Switch Affected: 1.1.1.0-2s and earlier
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T00:32:09.648Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2022-0013"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SonicWall Switch",
              "vendor": "SonicWall",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.1.1.0-2s and earlier"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Improper neutralization of special elements used in a user input allows an authenticated malicious user to perform remote code execution in the host system. This vulnerability impacts SonicWall Switch 1.1.1.0-2s and earlier versions"
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-77",
                  "description": "CWE-77: Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-07-29T19:15:12.000Z",
            "orgId": "44b2ff79-1416-4492-88bb-ed0da00c7315",
            "shortName": "sonicwall"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2022-0013"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "PSIRT@sonicwall.com",
              "ID": "CVE-2022-2323",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "SonicWall Switch",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "1.1.1.0-2s and earlier"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "SonicWall"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Improper neutralization of special elements used in a user input allows an authenticated malicious user to perform remote code execution in the host system. This vulnerability impacts SonicWall Switch 1.1.1.0-2s and earlier versions"
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-77: Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2022-0013",
                  "refsource": "CONFIRM",
                  "url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2022-0013"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "44b2ff79-1416-4492-88bb-ed0da00c7315",
        "assignerShortName": "sonicwall",
        "cveId": "CVE-2022-2323",
        "datePublished": "2022-07-29T19:15:12.000Z",
        "dateReserved": "2022-07-05T00:00:00.000Z",
        "dateUpdated": "2024-08-03T00:32:09.648Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-20024 (GCVE-0-2021-20024)

    Vulnerability from nvd – Published: 2021-07-09 21:25 – Updated: 2024-08-03 17:30
    VLAI
    Summary
    Multiple Out-of-Bound read vulnerability in SonicWall Switch when handling LLDP Protocol allows an attacker to cause a system instability or potentially read sensitive information from the memory locations.
    Severity
    No CVSS data available.
    CWE
    Assigner
    References
    Impacted products
    Vendor Product Version
    SonicWall SonicWall Switch Affected: 1.0.0.5-16 and earlier
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T17:30:07.421Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2021-0011"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SonicWall Switch",
              "vendor": "SonicWall",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.0.0.5-16 and earlier"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Multiple Out-of-Bound read vulnerability in SonicWall Switch when handling LLDP Protocol allows an attacker to cause a system instability or potentially read sensitive information from the memory locations."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-125",
                  "description": "CWE-125: Out-of-bounds Read",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-07-09T21:25:09.000Z",
            "orgId": "44b2ff79-1416-4492-88bb-ed0da00c7315",
            "shortName": "sonicwall"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2021-0011"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "PSIRT@sonicwall.com",
              "ID": "CVE-2021-20024",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "SonicWall Switch",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "1.0.0.5-16 and earlier"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "SonicWall"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Multiple Out-of-Bound read vulnerability in SonicWall Switch when handling LLDP Protocol allows an attacker to cause a system instability or potentially read sensitive information from the memory locations."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-125: Out-of-bounds Read"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2021-0011",
                  "refsource": "CONFIRM",
                  "url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2021-0011"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "44b2ff79-1416-4492-88bb-ed0da00c7315",
        "assignerShortName": "sonicwall",
        "cveId": "CVE-2021-20024",
        "datePublished": "2021-07-09T21:25:09.000Z",
        "dateReserved": "2020-12-17T00:00:00.000Z",
        "dateUpdated": "2024-08-03T17:30:07.421Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-2323 (GCVE-0-2022-2323)

    Vulnerability from cvelistv5 – Published: 2022-07-29 19:15 – Updated: 2024-08-03 00:32
    VLAI
    Summary
    Improper neutralization of special elements used in a user input allows an authenticated malicious user to perform remote code execution in the host system. This vulnerability impacts SonicWall Switch 1.1.1.0-2s and earlier versions
    Severity
    No CVSS data available.
    CWE
    • CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
    Assigner
    References
    Impacted products
    Vendor Product Version
    SonicWall SonicWall Switch Affected: 1.1.1.0-2s and earlier
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T00:32:09.648Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2022-0013"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SonicWall Switch",
              "vendor": "SonicWall",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.1.1.0-2s and earlier"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Improper neutralization of special elements used in a user input allows an authenticated malicious user to perform remote code execution in the host system. This vulnerability impacts SonicWall Switch 1.1.1.0-2s and earlier versions"
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-77",
                  "description": "CWE-77: Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-07-29T19:15:12.000Z",
            "orgId": "44b2ff79-1416-4492-88bb-ed0da00c7315",
            "shortName": "sonicwall"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2022-0013"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "PSIRT@sonicwall.com",
              "ID": "CVE-2022-2323",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "SonicWall Switch",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "1.1.1.0-2s and earlier"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "SonicWall"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Improper neutralization of special elements used in a user input allows an authenticated malicious user to perform remote code execution in the host system. This vulnerability impacts SonicWall Switch 1.1.1.0-2s and earlier versions"
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-77: Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2022-0013",
                  "refsource": "CONFIRM",
                  "url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2022-0013"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "44b2ff79-1416-4492-88bb-ed0da00c7315",
        "assignerShortName": "sonicwall",
        "cveId": "CVE-2022-2323",
        "datePublished": "2022-07-29T19:15:12.000Z",
        "dateReserved": "2022-07-05T00:00:00.000Z",
        "dateUpdated": "2024-08-03T00:32:09.648Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-20024 (GCVE-0-2021-20024)

    Vulnerability from cvelistv5 – Published: 2021-07-09 21:25 – Updated: 2024-08-03 17:30
    VLAI
    Summary
    Multiple Out-of-Bound read vulnerability in SonicWall Switch when handling LLDP Protocol allows an attacker to cause a system instability or potentially read sensitive information from the memory locations.
    Severity
    No CVSS data available.
    CWE
    Assigner
    References
    Impacted products
    Vendor Product Version
    SonicWall SonicWall Switch Affected: 1.0.0.5-16 and earlier
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T17:30:07.421Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2021-0011"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "SonicWall Switch",
              "vendor": "SonicWall",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.0.0.5-16 and earlier"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Multiple Out-of-Bound read vulnerability in SonicWall Switch when handling LLDP Protocol allows an attacker to cause a system instability or potentially read sensitive information from the memory locations."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-125",
                  "description": "CWE-125: Out-of-bounds Read",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-07-09T21:25:09.000Z",
            "orgId": "44b2ff79-1416-4492-88bb-ed0da00c7315",
            "shortName": "sonicwall"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2021-0011"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "PSIRT@sonicwall.com",
              "ID": "CVE-2021-20024",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "SonicWall Switch",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "1.0.0.5-16 and earlier"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "SonicWall"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Multiple Out-of-Bound read vulnerability in SonicWall Switch when handling LLDP Protocol allows an attacker to cause a system instability or potentially read sensitive information from the memory locations."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-125: Out-of-bounds Read"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2021-0011",
                  "refsource": "CONFIRM",
                  "url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2021-0011"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "44b2ff79-1416-4492-88bb-ed0da00c7315",
        "assignerShortName": "sonicwall",
        "cveId": "CVE-2021-20024",
        "datePublished": "2021-07-09T21:25:09.000Z",
        "dateReserved": "2020-12-17T00:00:00.000Z",
        "dateUpdated": "2024-08-03T17:30:07.421Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }