Search criteria
8 vulnerabilities found for Sensor Net Connect V2 by Plug&Track
CVE-2024-3083 (GCVE-0-2024-3083)
Vulnerability from nvd – Published: 2024-07-31 13:15 – Updated: 2024-09-30 14:06
VLAI?
Summary
A “CWE-352: Cross-Site Request Forgery (CSRF)” can be exploited by remote attackers to perform state-changing operations with administrative privileges by luring authenticated victims into visiting a malicious web page.
Severity ?
8.3 (High)
CWE
- CWE-352 - Cross-Site Request Forgery (CSRF)
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Plug&Track | Sensor Net Connect V2 |
Affected:
2.24
(semver)
|
Credits
Diego Zaffaroni of Nozomi Networks found this bug during a security research activity.
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-3083",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-01T19:45:25.353396Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-01T19:45:37.021Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Sensor Net Connect V2",
"vendor": "Plug\u0026Track",
"versions": [
{
"status": "affected",
"version": "2.24",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Diego Zaffaroni of Nozomi Networks found this bug during a security research activity."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A \u201cCWE-352: Cross-Site Request Forgery (CSRF)\u201d can be exploited by remote attackers to perform state-changing operations with administrative privileges by luring authenticated victims into visiting a malicious web page."
}
],
"value": "A \u201cCWE-352: Cross-Site Request Forgery (CSRF)\u201d can be exploited by remote attackers to perform state-changing operations with administrative privileges by luring authenticated victims into visiting a malicious web page."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "LOW",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-352",
"description": "CWE-352 Cross-Site Request Forgery (CSRF)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-30T14:06:48.156Z",
"orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
"shortName": "Nozomi"
},
"references": [
{
"url": "https://www.nozominetworks.com/labs/vulnerability-advisories-cve-2024-3083"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "No official patch available from vendor. Implement strict access controls for the temperature monitoring infrastructure. This includes preventing regular clients from accessing the web configuration interface, thereby limiting potential points of exploitation. Conduct regular and thorough reviews of logs and user accounts on systems running the Thermoscan IP software. This will help identify and address any suspicious activities early, ensuring that any potential security breaches are caught and remediated swiftly."
}
],
"value": "No official patch available from vendor. Implement strict access controls for the temperature monitoring infrastructure. This includes preventing regular clients from accessing the web configuration interface, thereby limiting potential points of exploitation. Conduct regular and thorough reviews of logs and user accounts on systems running the Thermoscan IP software. This will help identify and address any suspicious activities early, ensuring that any potential security breaches are caught and remediated swiftly."
}
],
"source": {
"discovery": "EXTERNAL"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
"assignerShortName": "Nozomi",
"cveId": "CVE-2024-3083",
"datePublished": "2024-07-31T13:15:35.210Z",
"dateReserved": "2024-03-29T08:32:17.261Z",
"dateUpdated": "2024-09-30T14:06:48.156Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-3082 (GCVE-0-2024-3082)
Vulnerability from nvd – Published: 2024-07-31 13:14 – Updated: 2024-09-30 14:26
VLAI?
Summary
A “CWE-256: Plaintext Storage of a Password” affecting the administrative account allows an attacker with physical access to the machine to retrieve the password in cleartext unless specific security measures at other layers (e.g., full-disk encryption) have been enabled.
Severity ?
4.2 (Medium)
CWE
- CWE-256 - Plaintext Storage of a Password
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Plug&Track | Sensor Net Connect V2 |
Affected:
2.24
(semver)
|
Credits
Diego Zaffaroni of Nozomi Networks found this bug during a security research activity.
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:h:proges:sensor_net_connect:2.24:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "sensor_net_connect",
"vendor": "proges",
"versions": [
{
"status": "affected",
"version": "2.24"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-3082",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-31T18:00:42.499438Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-07-31T18:06:29.284Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Sensor Net Connect V2",
"vendor": "Plug\u0026Track",
"versions": [
{
"status": "affected",
"version": "2.24",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Diego Zaffaroni of Nozomi Networks found this bug during a security research activity."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A \u201cCWE-256: Plaintext Storage of a Password\u201d affecting the administrative account allows an attacker with physical access to the machine to retrieve the password in cleartext unless specific security measures at other layers (e.g., full-disk encryption) have been enabled."
}
],
"value": "A \u201cCWE-256: Plaintext Storage of a Password\u201d affecting the administrative account allows an attacker with physical access to the machine to retrieve the password in cleartext unless specific security measures at other layers (e.g., full-disk encryption) have been enabled."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "PHYSICAL",
"availabilityImpact": "NONE",
"baseScore": 4.2,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:P/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-256",
"description": "CWE-256 Plaintext Storage of a Password",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-30T14:26:27.841Z",
"orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
"shortName": "Nozomi"
},
"references": [
{
"url": "https://www.nozominetworks.com/labs/vulnerability-advisories-cve-2024-3082"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "No official patch available from vendor. Implement strict access controls for the temperature monitoring infrastructure. This includes preventing regular clients from accessing the web configuration interface, thereby limiting potential points of exploitation. Conduct regular and thorough reviews of logs and user accounts on systems running the Thermoscan IP software. This will help identify and address any suspicious activities early, ensuring that any potential security breaches are caught and remediated swiftly."
}
],
"value": "No official patch available from vendor. Implement strict access controls for the temperature monitoring infrastructure. This includes preventing regular clients from accessing the web configuration interface, thereby limiting potential points of exploitation. Conduct regular and thorough reviews of logs and user accounts on systems running the Thermoscan IP software. This will help identify and address any suspicious activities early, ensuring that any potential security breaches are caught and remediated swiftly."
}
],
"source": {
"discovery": "EXTERNAL"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
"assignerShortName": "Nozomi",
"cveId": "CVE-2024-3082",
"datePublished": "2024-07-31T13:14:32.092Z",
"dateReserved": "2024-03-29T08:32:16.293Z",
"dateUpdated": "2024-09-30T14:26:27.841Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-31200 (GCVE-0-2024-31200)
Vulnerability from nvd – Published: 2024-07-31 13:16 – Updated: 2024-07-31 14:21
VLAI?
Summary
A “CWE-201: Insertion of Sensitive Information Into Sent Data” affecting the administrative account allows an attacker with physical access to the machine to retrieve the password in cleartext when an administrative session is open in the browser.
Severity ?
4.2 (Medium)
CWE
- CWE-201 - Insertion of Sensitive Information Into Sent Data
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Plug&Track | Sensor Net Connect V2 |
Affected:
2.24
(semver)
|
Credits
Diego Zaffaroni of Nozomi Networks found this bug during a security research activity.
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-31200",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-31T14:21:24.265264Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-07-31T14:21:55.581Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Sensor Net Connect V2",
"vendor": "Plug\u0026Track",
"versions": [
{
"status": "affected",
"version": "2.24",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Diego Zaffaroni of Nozomi Networks found this bug during a security research activity."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A \u201cCWE-201: Insertion of Sensitive Information Into Sent Data\u201d affecting the administrative account allows an attacker with physical access to the machine to retrieve the password in cleartext when an administrative session is open in the browser."
}
],
"value": "A \u201cCWE-201: Insertion of Sensitive Information Into Sent Data\u201d affecting the administrative account allows an attacker with physical access to the machine to retrieve the password in cleartext when an administrative session is open in the browser."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "PHYSICAL",
"availabilityImpact": "NONE",
"baseScore": 4.2,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:P/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-201",
"description": "CWE-201 Insertion of Sensitive Information Into Sent Data",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-07-31T13:16:57.751Z",
"orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
"shortName": "Nozomi"
},
"references": [
{
"url": "https://www.nozominetworks.com/labs/vulnerability-advisories-cve-2024-31200"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "No official patch available from vendor. Implement strict access controls for the temperature monitoring infrastructure. This includes preventing regular clients from accessing the web configuration interface, thereby limiting potential points of exploitation. Conduct regular and thorough reviews of logs and user accounts on systems running the Thermoscan IP software. This will help identify and address any suspicious activities early, ensuring that any potential security breaches are caught and remediated swiftly."
}
],
"value": "No official patch available from vendor. Implement strict access controls for the temperature monitoring infrastructure. This includes preventing regular clients from accessing the web configuration interface, thereby limiting potential points of exploitation. Conduct regular and thorough reviews of logs and user accounts on systems running the Thermoscan IP software. This will help identify and address any suspicious activities early, ensuring that any potential security breaches are caught and remediated swiftly."
}
],
"source": {
"discovery": "EXTERNAL"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
"assignerShortName": "Nozomi",
"cveId": "CVE-2024-31200",
"datePublished": "2024-07-31T13:16:57.751Z",
"dateReserved": "2024-03-29T08:32:14.699Z",
"dateUpdated": "2024-07-31T14:21:55.581Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-31199 (GCVE-0-2024-31199)
Vulnerability from nvd – Published: 2024-07-31 13:16 – Updated: 2024-09-30 14:07
VLAI?
Summary
A “CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')” allows malicious users to permanently inject arbitrary Javascript code.
Severity ?
8.8 (High)
CWE
- CWE-79 - Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting')
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Plug&Track | Sensor Net Connect V2 |
Affected:
2.24
(semver)
|
Credits
Diego Zaffaroni of Nozomi Networks found this bug during a security research activity.
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-31199",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-31T13:33:41.502383Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-07-31T13:35:12.228Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Sensor Net Connect V2",
"vendor": "Plug\u0026Track",
"versions": [
{
"status": "affected",
"version": "2.24",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Diego Zaffaroni of Nozomi Networks found this bug during a security research activity."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A \u201cCWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)\u201d allows malicious users to permanently inject arbitrary Javascript code."
}
],
"value": "A \u201cCWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)\u201d allows malicious users to permanently inject arbitrary Javascript code."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79 Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-30T14:07:42.327Z",
"orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
"shortName": "Nozomi"
},
"references": [
{
"url": "https://www.nozominetworks.com/labs/vulnerability-advisories-cve-2024-31199"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "No official patch available from vendor. Implement strict access controls for the temperature monitoring infrastructure. This includes preventing regular clients from accessing the web configuration interface, thereby limiting potential points of exploitation. Conduct regular and thorough reviews of logs and user accounts on systems running the Thermoscan IP software. This will help identify and address any suspicious activities early, ensuring that any potential security breaches are caught and remediated swiftly."
}
],
"value": "No official patch available from vendor. Implement strict access controls for the temperature monitoring infrastructure. This includes preventing regular clients from accessing the web configuration interface, thereby limiting potential points of exploitation. Conduct regular and thorough reviews of logs and user accounts on systems running the Thermoscan IP software. This will help identify and address any suspicious activities early, ensuring that any potential security breaches are caught and remediated swiftly."
}
],
"source": {
"discovery": "EXTERNAL"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
"assignerShortName": "Nozomi",
"cveId": "CVE-2024-31199",
"datePublished": "2024-07-31T13:16:16.628Z",
"dateReserved": "2024-03-29T08:32:14.699Z",
"dateUpdated": "2024-09-30T14:07:42.327Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-31200 (GCVE-0-2024-31200)
Vulnerability from cvelistv5 – Published: 2024-07-31 13:16 – Updated: 2024-07-31 14:21
VLAI?
Summary
A “CWE-201: Insertion of Sensitive Information Into Sent Data” affecting the administrative account allows an attacker with physical access to the machine to retrieve the password in cleartext when an administrative session is open in the browser.
Severity ?
4.2 (Medium)
CWE
- CWE-201 - Insertion of Sensitive Information Into Sent Data
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Plug&Track | Sensor Net Connect V2 |
Affected:
2.24
(semver)
|
Credits
Diego Zaffaroni of Nozomi Networks found this bug during a security research activity.
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-31200",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-31T14:21:24.265264Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-07-31T14:21:55.581Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Sensor Net Connect V2",
"vendor": "Plug\u0026Track",
"versions": [
{
"status": "affected",
"version": "2.24",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Diego Zaffaroni of Nozomi Networks found this bug during a security research activity."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A \u201cCWE-201: Insertion of Sensitive Information Into Sent Data\u201d affecting the administrative account allows an attacker with physical access to the machine to retrieve the password in cleartext when an administrative session is open in the browser."
}
],
"value": "A \u201cCWE-201: Insertion of Sensitive Information Into Sent Data\u201d affecting the administrative account allows an attacker with physical access to the machine to retrieve the password in cleartext when an administrative session is open in the browser."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "PHYSICAL",
"availabilityImpact": "NONE",
"baseScore": 4.2,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:P/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-201",
"description": "CWE-201 Insertion of Sensitive Information Into Sent Data",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-07-31T13:16:57.751Z",
"orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
"shortName": "Nozomi"
},
"references": [
{
"url": "https://www.nozominetworks.com/labs/vulnerability-advisories-cve-2024-31200"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "No official patch available from vendor. Implement strict access controls for the temperature monitoring infrastructure. This includes preventing regular clients from accessing the web configuration interface, thereby limiting potential points of exploitation. Conduct regular and thorough reviews of logs and user accounts on systems running the Thermoscan IP software. This will help identify and address any suspicious activities early, ensuring that any potential security breaches are caught and remediated swiftly."
}
],
"value": "No official patch available from vendor. Implement strict access controls for the temperature monitoring infrastructure. This includes preventing regular clients from accessing the web configuration interface, thereby limiting potential points of exploitation. Conduct regular and thorough reviews of logs and user accounts on systems running the Thermoscan IP software. This will help identify and address any suspicious activities early, ensuring that any potential security breaches are caught and remediated swiftly."
}
],
"source": {
"discovery": "EXTERNAL"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
"assignerShortName": "Nozomi",
"cveId": "CVE-2024-31200",
"datePublished": "2024-07-31T13:16:57.751Z",
"dateReserved": "2024-03-29T08:32:14.699Z",
"dateUpdated": "2024-07-31T14:21:55.581Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-31199 (GCVE-0-2024-31199)
Vulnerability from cvelistv5 – Published: 2024-07-31 13:16 – Updated: 2024-09-30 14:07
VLAI?
Summary
A “CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')” allows malicious users to permanently inject arbitrary Javascript code.
Severity ?
8.8 (High)
CWE
- CWE-79 - Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting')
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Plug&Track | Sensor Net Connect V2 |
Affected:
2.24
(semver)
|
Credits
Diego Zaffaroni of Nozomi Networks found this bug during a security research activity.
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-31199",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-31T13:33:41.502383Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-07-31T13:35:12.228Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Sensor Net Connect V2",
"vendor": "Plug\u0026Track",
"versions": [
{
"status": "affected",
"version": "2.24",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Diego Zaffaroni of Nozomi Networks found this bug during a security research activity."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A \u201cCWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)\u201d allows malicious users to permanently inject arbitrary Javascript code."
}
],
"value": "A \u201cCWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)\u201d allows malicious users to permanently inject arbitrary Javascript code."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79 Improper Neutralization of Input During Web Page Generation (XSS or \u0027Cross-site Scripting\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-30T14:07:42.327Z",
"orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
"shortName": "Nozomi"
},
"references": [
{
"url": "https://www.nozominetworks.com/labs/vulnerability-advisories-cve-2024-31199"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "No official patch available from vendor. Implement strict access controls for the temperature monitoring infrastructure. This includes preventing regular clients from accessing the web configuration interface, thereby limiting potential points of exploitation. Conduct regular and thorough reviews of logs and user accounts on systems running the Thermoscan IP software. This will help identify and address any suspicious activities early, ensuring that any potential security breaches are caught and remediated swiftly."
}
],
"value": "No official patch available from vendor. Implement strict access controls for the temperature monitoring infrastructure. This includes preventing regular clients from accessing the web configuration interface, thereby limiting potential points of exploitation. Conduct regular and thorough reviews of logs and user accounts on systems running the Thermoscan IP software. This will help identify and address any suspicious activities early, ensuring that any potential security breaches are caught and remediated swiftly."
}
],
"source": {
"discovery": "EXTERNAL"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
"assignerShortName": "Nozomi",
"cveId": "CVE-2024-31199",
"datePublished": "2024-07-31T13:16:16.628Z",
"dateReserved": "2024-03-29T08:32:14.699Z",
"dateUpdated": "2024-09-30T14:07:42.327Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-3083 (GCVE-0-2024-3083)
Vulnerability from cvelistv5 – Published: 2024-07-31 13:15 – Updated: 2024-09-30 14:06
VLAI?
Summary
A “CWE-352: Cross-Site Request Forgery (CSRF)” can be exploited by remote attackers to perform state-changing operations with administrative privileges by luring authenticated victims into visiting a malicious web page.
Severity ?
8.3 (High)
CWE
- CWE-352 - Cross-Site Request Forgery (CSRF)
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Plug&Track | Sensor Net Connect V2 |
Affected:
2.24
(semver)
|
Credits
Diego Zaffaroni of Nozomi Networks found this bug during a security research activity.
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-3083",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-01T19:45:25.353396Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-01T19:45:37.021Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Sensor Net Connect V2",
"vendor": "Plug\u0026Track",
"versions": [
{
"status": "affected",
"version": "2.24",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Diego Zaffaroni of Nozomi Networks found this bug during a security research activity."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A \u201cCWE-352: Cross-Site Request Forgery (CSRF)\u201d can be exploited by remote attackers to perform state-changing operations with administrative privileges by luring authenticated victims into visiting a malicious web page."
}
],
"value": "A \u201cCWE-352: Cross-Site Request Forgery (CSRF)\u201d can be exploited by remote attackers to perform state-changing operations with administrative privileges by luring authenticated victims into visiting a malicious web page."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "LOW",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-352",
"description": "CWE-352 Cross-Site Request Forgery (CSRF)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-30T14:06:48.156Z",
"orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
"shortName": "Nozomi"
},
"references": [
{
"url": "https://www.nozominetworks.com/labs/vulnerability-advisories-cve-2024-3083"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "No official patch available from vendor. Implement strict access controls for the temperature monitoring infrastructure. This includes preventing regular clients from accessing the web configuration interface, thereby limiting potential points of exploitation. Conduct regular and thorough reviews of logs and user accounts on systems running the Thermoscan IP software. This will help identify and address any suspicious activities early, ensuring that any potential security breaches are caught and remediated swiftly."
}
],
"value": "No official patch available from vendor. Implement strict access controls for the temperature monitoring infrastructure. This includes preventing regular clients from accessing the web configuration interface, thereby limiting potential points of exploitation. Conduct regular and thorough reviews of logs and user accounts on systems running the Thermoscan IP software. This will help identify and address any suspicious activities early, ensuring that any potential security breaches are caught and remediated swiftly."
}
],
"source": {
"discovery": "EXTERNAL"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
"assignerShortName": "Nozomi",
"cveId": "CVE-2024-3083",
"datePublished": "2024-07-31T13:15:35.210Z",
"dateReserved": "2024-03-29T08:32:17.261Z",
"dateUpdated": "2024-09-30T14:06:48.156Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-3082 (GCVE-0-2024-3082)
Vulnerability from cvelistv5 – Published: 2024-07-31 13:14 – Updated: 2024-09-30 14:26
VLAI?
Summary
A “CWE-256: Plaintext Storage of a Password” affecting the administrative account allows an attacker with physical access to the machine to retrieve the password in cleartext unless specific security measures at other layers (e.g., full-disk encryption) have been enabled.
Severity ?
4.2 (Medium)
CWE
- CWE-256 - Plaintext Storage of a Password
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Plug&Track | Sensor Net Connect V2 |
Affected:
2.24
(semver)
|
Credits
Diego Zaffaroni of Nozomi Networks found this bug during a security research activity.
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:h:proges:sensor_net_connect:2.24:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "sensor_net_connect",
"vendor": "proges",
"versions": [
{
"status": "affected",
"version": "2.24"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-3082",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-31T18:00:42.499438Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-07-31T18:06:29.284Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Sensor Net Connect V2",
"vendor": "Plug\u0026Track",
"versions": [
{
"status": "affected",
"version": "2.24",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Diego Zaffaroni of Nozomi Networks found this bug during a security research activity."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A \u201cCWE-256: Plaintext Storage of a Password\u201d affecting the administrative account allows an attacker with physical access to the machine to retrieve the password in cleartext unless specific security measures at other layers (e.g., full-disk encryption) have been enabled."
}
],
"value": "A \u201cCWE-256: Plaintext Storage of a Password\u201d affecting the administrative account allows an attacker with physical access to the machine to retrieve the password in cleartext unless specific security measures at other layers (e.g., full-disk encryption) have been enabled."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "PHYSICAL",
"availabilityImpact": "NONE",
"baseScore": 4.2,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:P/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-256",
"description": "CWE-256 Plaintext Storage of a Password",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-30T14:26:27.841Z",
"orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
"shortName": "Nozomi"
},
"references": [
{
"url": "https://www.nozominetworks.com/labs/vulnerability-advisories-cve-2024-3082"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "No official patch available from vendor. Implement strict access controls for the temperature monitoring infrastructure. This includes preventing regular clients from accessing the web configuration interface, thereby limiting potential points of exploitation. Conduct regular and thorough reviews of logs and user accounts on systems running the Thermoscan IP software. This will help identify and address any suspicious activities early, ensuring that any potential security breaches are caught and remediated swiftly."
}
],
"value": "No official patch available from vendor. Implement strict access controls for the temperature monitoring infrastructure. This includes preventing regular clients from accessing the web configuration interface, thereby limiting potential points of exploitation. Conduct regular and thorough reviews of logs and user accounts on systems running the Thermoscan IP software. This will help identify and address any suspicious activities early, ensuring that any potential security breaches are caught and remediated swiftly."
}
],
"source": {
"discovery": "EXTERNAL"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
"assignerShortName": "Nozomi",
"cveId": "CVE-2024-3082",
"datePublished": "2024-07-31T13:14:32.092Z",
"dateReserved": "2024-03-29T08:32:16.293Z",
"dateUpdated": "2024-09-30T14:26:27.841Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}