Search
Find a vulnerability
Search criteria
50 vulnerabilities found for SIPLUS IPC427E by Siemens
CVE-2025-2884 (GCVE-0-2025-2884)
Vulnerability from nvd – Published: 2025-06-10 17:29 – Updated: 2026-08-11 12:22
VLAI
EPSS
VEX
Title
Out-of-Bounds read vulnerability in TCG TPM2.0 reference implementation
Summary
TCG TPM2.0 Reference implementation's CryptHmacSign helper function is vulnerable to Out-of-Bounds read due to the lack of validation the signature scheme with the signature key's algorithm. See Errata Revision 1.83 and advisory TCGVRT0009 for TCG standard TPM2.0
Severity
6.6 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
Mission & Well-being: medium
certcc
Decision recorded 2025-06-13 17:22 UTC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-06-13 01:41 UTC
CWE
- CWE-125 Out-of-bounds Read
- CWE-125 - Out-of-bounds Read
Assigner
References
8 references
Impacted products
25 products
| Vendor | Product | Version | |
|---|---|---|---|
| Trusted Computing Group | TPM2.0 |
Affected:
0 , < 1.83
(custom)
|
|
| Siemens | SIMATIC CN 4100 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIMATIC Field PG M5 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIMATIC Field PG M6 |
Affected:
0 , < V26.01.14
(custom)
|
|
| Siemens | SIMATIC IPC BX-32A |
Affected:
0 , < V29.01.09
(custom)
|
|
| Siemens | SIMATIC IPC BX-39A |
Affected:
0 , < V29.01.09
(custom)
|
|
| Siemens | SIMATIC IPC BX-56A |
Affected:
0 , < V32.01.09
(custom)
|
|
| Siemens | SIMATIC IPC BX-59A |
Affected:
0 , < V32.01.09
(custom)
|
|
| Siemens | SIMATIC IPC MD-57A |
Affected:
0 , < V30.01.10
(custom)
|
|
| Siemens | SIMATIC IPC PX-32A |
Affected:
0 , < V29.01.09
(custom)
|
|
| Siemens | SIMATIC IPC PX-39A |
Affected:
0 , < V29.01.09
(custom)
|
|
| Siemens | SIMATIC IPC PX-39A PRO |
Affected:
0 , < V29.01.09
(custom)
|
|
| Siemens | SIMATIC IPC RW-528A |
Affected:
0 , < V34.01.02
(custom)
|
|
| Siemens | SIMATIC IPC RW-548A |
Affected:
0 , < V34.01.02
(custom)
|
|
| Siemens | SIMATIC IPC227E |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIMATIC IPC277E |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIMATIC IPC427E |
Affected:
0 , < V21.01.20
(custom)
|
|
| Siemens | SIMATIC IPC477E |
Affected:
0 , < V21.01.20
(custom)
|
|
| Siemens | SIMATIC IPC477E PRO |
Affected:
0 , < V21.01.20
(custom)
|
|
| Siemens | SIMATIC IPC627E |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIMATIC IPC647E |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIMATIC IPC677E |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIMATIC IPC847E |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIMATIC ITP1000 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIPLUS IPC427E |
Affected:
0 , < V21.01.20
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2025-06-10T19:02:29.811Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-01209.html"
},
{
"url": "https://www.kb.cert.org/vuls/id/282450"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 6.6,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:N/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2025-2884",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-06-13T01:41:10.489446Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125 Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-06-13T01:46:13.802Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC CN 4100",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Field PG M5",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Field PG M6",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V26.01.14",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC BX-32A",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V29.01.09",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC BX-39A",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V29.01.09",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC BX-56A",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V32.01.09",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC BX-59A",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V32.01.09",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC MD-57A",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V30.01.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC PX-32A",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V29.01.09",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC PX-39A",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V29.01.09",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC PX-39A PRO",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V29.01.09",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC RW-528A",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V34.01.02",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC RW-548A",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V34.01.02",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC227E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC277E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC427E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.20",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC477E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.20",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC477E PRO",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.20",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC627E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC647E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC677E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC847E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ITP1000",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS IPC427E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.20",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-08-11T12:22:36.753Z",
"orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
"shortName": "siemens-SADP"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-628843.html"
}
],
"x_adpType": "supplier"
}
],
"cna": {
"affected": [
{
"product": "TPM2.0",
"vendor": "Trusted Computing Group",
"versions": [
{
"lessThan": "1.83",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "TCG TPM2.0 Reference implementation\u0027s CryptHmacSign helper function is vulnerable to Out-of-Bounds read due to the lack of validation the signature scheme with the signature key\u0027s algorithm. See Errata Revision 1.83 and advisory TCGVRT0009 for TCG standard TPM2.0"
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-2884",
"selections": [
{
"name": "Exploitation",
"namespace": "ssvc",
"values": [
"none"
],
"version": "1.0.0"
},
{
"name": "Automatable",
"namespace": "ssvc",
"values": [
"no"
],
"version": "2.0.0"
},
{
"name": "Technical Impact",
"namespace": "ssvc",
"values": [
"partial"
],
"version": "1.0.0"
},
{
"name": "Mission \u0026 Well-being",
"namespace": "ssvc",
"values": [
"medium"
],
"version": "1.0.0"
}
],
"timestamp": "2025-06-13T17:22:30.584Z"
},
"type": "ssvcV1_0_1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "CWE-125 Out-of-bounds Read",
"lang": "en"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-06-13T18:22:21.856Z",
"orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
"shortName": "certcc"
},
"references": [
{
"url": "https://trustedcomputinggroup.org/about/security/"
},
{
"name": "TPM2.0 Errata",
"url": "https://trustedcomputinggroup.org/wp-content/uploads/TPM2.0-Library-Spec-v1.83-Errata_v1_pub.pdf"
},
{
"name": "Vendor Advisory",
"url": "https://trustedcomputinggroup.org/wp-content/uploads/VRT0009-Advisory-FINAL.pdf"
},
{
"name": "Vendor Patch",
"url": "https://github.com/stefanberger/libtpms/commit/04b2d8e9afc0a9b6bffe562a23e58c0de11532d1"
},
{
"name": "Related CVE",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-49133"
}
],
"source": {
"discovery": "INTERNAL"
},
"title": "Out-of-Bounds read vulnerability in TCG TPM2.0 reference implementation",
"x_generator": {
"engine": "VINCE 3.0.20",
"env": "prod",
"origin": "https://cveawg.mitre.org/api/cve/CVE-2025-2884"
}
}
},
"cveMetadata": {
"assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
"assignerShortName": "certcc",
"cveId": "CVE-2025-2884",
"datePublished": "2025-06-10T17:29:19.463Z",
"dateReserved": "2025-03-27T21:01:41.908Z",
"dateUpdated": "2026-08-11T12:22:36.753Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2022-21198 (GCVE-0-2022-21198)
Vulnerability from nvd – Published: 2022-11-11 15:49 – Updated: 2026-08-11 12:22
VLAI
EPSS
VEX
Summary
Time-of-check time-of-use race condition in the BIOS firmware for some Intel(R) Processors may allow a privileged user to potentially enable escalation of privilege via local access.
Severity
7.9 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-01-29 20:38 UTC
CWE
- escalation of privilege
- CWE-367 - Time-of-check Time-of-use (TOCTOU) Race Condition
Assigner
References
Impacted products
15 products
| Vendor | Product | Version | |
|---|---|---|---|
| n/a | Intel(R) Processors |
Affected:
See references
|
|
| Siemens | SIMATIC Field PG M5 |
Affected:
0 , < V22.01.11
(custom)
|
|
| Siemens | SIMATIC Field PG M6 |
Affected:
0 , < V26.01.11
(custom)
|
|
| Siemens | SIMATIC IPC BX-39A |
Affected:
0 , < V29.01.03
(custom)
|
|
| Siemens | SIMATIC IPC PX-39A |
Affected:
0 , < V29.01.03
(custom)
|
|
| Siemens | SIMATIC IPC PX-39A PRO |
Affected:
0 , < V29.01.03
(custom)
|
|
| Siemens | SIMATIC IPC427E |
Affected:
0 , < V21.01.19
(custom)
|
|
| Siemens | SIMATIC IPC477E |
Affected:
0 , < V21.01.19
(custom)
|
|
| Siemens | SIMATIC IPC477E PRO |
Affected:
0 , < V21.01.19
(custom)
|
|
| Siemens | SIMATIC IPC627E |
Affected:
0 , < V25.02.14
(custom)
|
|
| Siemens | SIMATIC IPC647E |
Affected:
0 , < V25.02.14
(custom)
|
|
| Siemens | SIMATIC IPC677E |
Affected:
0 , < V25.02.14
(custom)
|
|
| Siemens | SIMATIC IPC847E |
Affected:
0 , < V25.02.14
(custom)
|
|
| Siemens | SIMATIC ITP1000 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIPLUS IPC427E |
Affected:
0 , < V21.01.19
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T02:31:59.787Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00688.html",
"tags": [
"x_transferred"
],
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00688.html"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-21198",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-29T20:38:21.227981Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-367",
"description": "CWE-367 Time-of-check Time-of-use (TOCTOU) Race Condition",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-04T17:58:34.848Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC Field PG M5",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V22.01.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Field PG M6",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V26.01.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC BX-39A",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V29.01.03",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC PX-39A",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V29.01.03",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC PX-39A PRO",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V29.01.03",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC427E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.19",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC477E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.19",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC477E PRO",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.19",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC627E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.14",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC647E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.14",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC677E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.14",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC847E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.14",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ITP1000",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS IPC427E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.19",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-08-11T12:22:27.669Z",
"orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
"shortName": "siemens-SADP"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-686975.html"
}
],
"x_adpType": "supplier"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Intel(R) Processors",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "See references"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Time-of-check time-of-use race condition in the BIOS firmware for some Intel(R) Processors may allow a privileged user to potentially enable escalation of privilege via local access."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.9,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:N/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "escalation of privilege",
"lang": "en"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-11-14T17:46:28.257Z",
"orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"shortName": "intel"
},
"references": [
{
"name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00688.html",
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00688.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"assignerShortName": "intel",
"cveId": "CVE-2022-21198",
"datePublished": "2022-11-11T15:49:10.831Z",
"dateReserved": "2022-02-18T21:23:59.775Z",
"dateUpdated": "2026-08-11T12:22:27.669Z",
"requesterUserId": "524a9a6b-3515-4b97-ab85-1a9a79493852",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2022-24031 (GCVE-0-2022-24031)
Vulnerability from nvd – Published: 2022-02-03 01:59 – Updated: 2026-08-11 12:22
VLAI
EPSS
VEX
Summary
An issue was discovered in NvmExpressDxe in Insyde InsydeH2O with kernel 5.1 through 5.5. An SMM memory corruption vulnerability allows an attacker to write fixed or predictable data to SMRAM. Exploiting this issue could lead to escalating privileges to SMM.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
6 references
| URL | Tags |
|---|---|
| https://www.insyde.com/security-pledge | x_refsource_MISC |
| https://www.insyde.com/security-pledge/SA-2022015 | x_refsource_MISC |
| https://security.netapp.com/advisory/ntap-2022021… | x_refsource_CONFIRM |
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_CONFIRM |
| https://www.kb.cert.org/vuls/id/796611 | |
| https://cert-portal.siemens.com/productcert/html/… |
Impacted products
18 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | RUGGEDCOM APE1808 - BIOS |
Affected:
0 , < V1.0.202N
(custom)
|
|
| Siemens | SIMATIC Field PG M5 |
Affected:
0 , < V22.01.10
(custom)
|
|
| Siemens | SIMATIC Field PG M6 |
Affected:
0 , < V26.01.13
(custom)
|
|
| Siemens | SIMATIC IPC127E |
Affected:
0 , < V27.01.09
(custom)
|
|
| Siemens | SIMATIC IPC227G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC277G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC277G PRO |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC327G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC377G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC427E |
Affected:
0 , < V21.01.17
(custom)
|
|
| Siemens | SIMATIC IPC477E |
Affected:
0 , < V21.01.17
(custom)
|
|
| Siemens | SIMATIC IPC477E PRO |
Affected:
0 , < V21.01.17
(custom)
|
|
| Siemens | SIMATIC IPC627E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC IPC647E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC IPC677E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC IPC847E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC ITP1000 |
Affected:
0 , < V23.01.10
(custom)
|
|
| Siemens | SIPLUS IPC427E |
Affected:
0 , < V21.01.17
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2025-11-04T19:12:59.895Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.insyde.com/security-pledge"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.insyde.com/security-pledge/SA-2022015"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://security.netapp.com/advisory/ntap-20220216-0009/"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
},
{
"url": "https://www.kb.cert.org/vuls/id/796611"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM APE1808 - BIOS",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.0.202N",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Field PG M5",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V22.01.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Field PG M6",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V26.01.13",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC127E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V27.01.09",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC227G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC277G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC\u00a0IPC277G PRO",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC327G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC377G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC427E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC477E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC477E PRO",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC627E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC647E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC677E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC847E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ITP1000",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V23.01.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS IPC427E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-08-11T12:22:29.973Z",
"orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
"shortName": "siemens-SADP"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-306654.html"
}
],
"x_adpType": "supplier"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered in NvmExpressDxe in Insyde InsydeH2O with kernel 5.1 through 5.5. An SMM memory corruption vulnerability allows an attacker to write fixed or predictable data to SMRAM. Exploiting this issue could lead to escalating privileges to SMM."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-02-22T19:06:47.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.insyde.com/security-pledge"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.insyde.com/security-pledge/SA-2022015"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://security.netapp.com/advisory/ntap-20220216-0009/"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2022-24031",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An issue was discovered in NvmExpressDxe in Insyde InsydeH2O with kernel 5.1 through 5.5. An SMM memory corruption vulnerability allows an attacker to write fixed or predictable data to SMRAM. Exploiting this issue could lead to escalating privileges to SMM."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.insyde.com/security-pledge",
"refsource": "MISC",
"url": "https://www.insyde.com/security-pledge"
},
{
"name": "https://www.insyde.com/security-pledge/SA-2022015",
"refsource": "MISC",
"url": "https://www.insyde.com/security-pledge/SA-2022015"
},
{
"name": "https://security.netapp.com/advisory/ntap-20220216-0009/",
"refsource": "CONFIRM",
"url": "https://security.netapp.com/advisory/ntap-20220216-0009/"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2022-24031",
"datePublished": "2022-02-03T01:59:49.000Z",
"dateReserved": "2022-01-26T00:00:00.000Z",
"dateUpdated": "2026-08-11T12:22:29.973Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2022-24030 (GCVE-0-2022-24030)
Vulnerability from nvd – Published: 2022-02-03 01:16 – Updated: 2026-08-11 12:22
VLAI
EPSS
VEX
Summary
An issue was discovered in AhciBusDxe in Insyde InsydeH2O with kernel 5.1 through 5.5. An SMM memory corruption vulnerability allows an attacker to write fixed or predictable data to SMRAM. Exploiting this issue could lead to escalating privileges to SMM.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
6 references
| URL | Tags |
|---|---|
| https://www.insyde.com/security-pledge | x_refsource_MISC |
| https://www.insyde.com/security-pledge/SA-2022011 | x_refsource_MISC |
| https://security.netapp.com/advisory/ntap-2022021… | x_refsource_CONFIRM |
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_CONFIRM |
| https://www.kb.cert.org/vuls/id/796611 | |
| https://cert-portal.siemens.com/productcert/html/… |
Impacted products
18 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | RUGGEDCOM APE1808 - BIOS |
Affected:
0 , < V1.0.202N
(custom)
|
|
| Siemens | SIMATIC Field PG M5 |
Affected:
0 , < V22.01.10
(custom)
|
|
| Siemens | SIMATIC Field PG M6 |
Affected:
0 , < V26.01.13
(custom)
|
|
| Siemens | SIMATIC IPC127E |
Affected:
0 , < V27.01.09
(custom)
|
|
| Siemens | SIMATIC IPC227G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC277G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC277G PRO |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC327G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC377G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC427E |
Affected:
0 , < V21.01.17
(custom)
|
|
| Siemens | SIMATIC IPC477E |
Affected:
0 , < V21.01.17
(custom)
|
|
| Siemens | SIMATIC IPC477E PRO |
Affected:
0 , < V21.01.17
(custom)
|
|
| Siemens | SIMATIC IPC627E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC IPC647E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC IPC677E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC IPC847E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC ITP1000 |
Affected:
0 , < V23.01.10
(custom)
|
|
| Siemens | SIPLUS IPC427E |
Affected:
0 , < V21.01.17
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2025-11-04T19:12:58.761Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.insyde.com/security-pledge"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.insyde.com/security-pledge/SA-2022011"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://security.netapp.com/advisory/ntap-20220216-0011/"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
},
{
"url": "https://www.kb.cert.org/vuls/id/796611"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM APE1808 - BIOS",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.0.202N",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Field PG M5",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V22.01.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Field PG M6",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V26.01.13",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC127E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V27.01.09",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC227G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC277G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC\u00a0IPC277G PRO",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC327G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC377G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC427E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC477E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC477E PRO",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC627E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC647E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC677E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC847E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ITP1000",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V23.01.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS IPC427E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-08-11T12:22:28.819Z",
"orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
"shortName": "siemens-SADP"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-306654.html"
}
],
"x_adpType": "supplier"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered in AhciBusDxe in Insyde InsydeH2O with kernel 5.1 through 5.5. An SMM memory corruption vulnerability allows an attacker to write fixed or predictable data to SMRAM. Exploiting this issue could lead to escalating privileges to SMM."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-02-22T19:07:07.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.insyde.com/security-pledge"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.insyde.com/security-pledge/SA-2022011"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://security.netapp.com/advisory/ntap-20220216-0011/"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2022-24030",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An issue was discovered in AhciBusDxe in Insyde InsydeH2O with kernel 5.1 through 5.5. An SMM memory corruption vulnerability allows an attacker to write fixed or predictable data to SMRAM. Exploiting this issue could lead to escalating privileges to SMM."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.insyde.com/security-pledge",
"refsource": "MISC",
"url": "https://www.insyde.com/security-pledge"
},
{
"name": "https://www.insyde.com/security-pledge/SA-2022011",
"refsource": "MISC",
"url": "https://www.insyde.com/security-pledge/SA-2022011"
},
{
"name": "https://security.netapp.com/advisory/ntap-20220216-0011/",
"refsource": "CONFIRM",
"url": "https://security.netapp.com/advisory/ntap-20220216-0011/"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2022-24030",
"datePublished": "2022-02-03T01:16:51.000Z",
"dateReserved": "2022-01-26T00:00:00.000Z",
"dateUpdated": "2026-08-11T12:22:28.819Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2021-43615 (GCVE-0-2021-43615)
Vulnerability from nvd – Published: 2022-02-03 01:09 – Updated: 2026-08-11 12:22
VLAI
EPSS
VEX
Summary
An issue was discovered in HddPassword in Insyde InsydeH2O with kernel 5.1 before 05.16.23, 5.2 before 05.26.23, 5.3 before 05.35.23, 5.4 before 05.43.22, and 5.5 before 05.51.22. An SMM memory corruption vulnerability allows an attacker to write fixed or predictable data to SMRAM. Exploiting this issue could lead to escalating privileges to SMM.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
6 references
| URL | Tags |
|---|---|
| https://www.insyde.com/security-pledge | x_refsource_MISC |
| https://www.insyde.com/security-pledge/SA-2022013 | x_refsource_MISC |
| https://security.netapp.com/advisory/ntap-2022021… | x_refsource_CONFIRM |
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_CONFIRM |
| https://www.kb.cert.org/vuls/id/796611 | |
| https://cert-portal.siemens.com/productcert/html/… |
Impacted products
18 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | RUGGEDCOM APE1808 - BIOS |
Affected:
0 , < V1.0.202N
(custom)
|
|
| Siemens | SIMATIC Field PG M5 |
Affected:
0 , < V22.01.10
(custom)
|
|
| Siemens | SIMATIC Field PG M6 |
Affected:
0 , < V26.01.13
(custom)
|
|
| Siemens | SIMATIC IPC127E |
Affected:
0 , < V27.01.09
(custom)
|
|
| Siemens | SIMATIC IPC227G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC277G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC277G PRO |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC327G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC377G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC427E |
Affected:
0 , < V21.01.17
(custom)
|
|
| Siemens | SIMATIC IPC477E |
Affected:
0 , < V21.01.17
(custom)
|
|
| Siemens | SIMATIC IPC477E PRO |
Affected:
0 , < V21.01.17
(custom)
|
|
| Siemens | SIMATIC IPC627E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC IPC647E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC IPC677E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC IPC847E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC ITP1000 |
Affected:
0 , < V23.01.10
(custom)
|
|
| Siemens | SIPLUS IPC427E |
Affected:
0 , < V21.01.17
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2025-11-04T19:12:46.366Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.insyde.com/security-pledge"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.insyde.com/security-pledge/SA-2022013"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://security.netapp.com/advisory/ntap-20220216-0010/"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
},
{
"url": "https://www.kb.cert.org/vuls/id/796611"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM APE1808 - BIOS",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.0.202N",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Field PG M5",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V22.01.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Field PG M6",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V26.01.13",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC127E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V27.01.09",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC227G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC277G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC\u00a0IPC277G PRO",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC327G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC377G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC427E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC477E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC477E PRO",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC627E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC647E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC677E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC847E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ITP1000",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V23.01.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS IPC427E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-08-11T12:22:22.919Z",
"orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
"shortName": "siemens-SADP"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-306654.html"
}
],
"x_adpType": "supplier"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered in HddPassword in Insyde InsydeH2O with kernel 5.1 before 05.16.23, 5.2 before 05.26.23, 5.3 before 05.35.23, 5.4 before 05.43.22, and 5.5 before 05.51.22. An SMM memory corruption vulnerability allows an attacker to write fixed or predictable data to SMRAM. Exploiting this issue could lead to escalating privileges to SMM."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-02-22T19:06:51.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.insyde.com/security-pledge"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.insyde.com/security-pledge/SA-2022013"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://security.netapp.com/advisory/ntap-20220216-0010/"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2021-43615",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An issue was discovered in HddPassword in Insyde InsydeH2O with kernel 5.1 before 05.16.23, 5.2 before 05.26.23, 5.3 before 05.35.23, 5.4 before 05.43.22, and 5.5 before 05.51.22. An SMM memory corruption vulnerability allows an attacker to write fixed or predictable data to SMRAM. Exploiting this issue could lead to escalating privileges to SMM."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.insyde.com/security-pledge",
"refsource": "MISC",
"url": "https://www.insyde.com/security-pledge"
},
{
"name": "https://www.insyde.com/security-pledge/SA-2022013",
"refsource": "MISC",
"url": "https://www.insyde.com/security-pledge/SA-2022013"
},
{
"name": "https://security.netapp.com/advisory/ntap-20220216-0010/",
"refsource": "CONFIRM",
"url": "https://security.netapp.com/advisory/ntap-20220216-0010/"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2021-43615",
"datePublished": "2022-02-03T01:09:57.000Z",
"dateReserved": "2021-11-13T00:00:00.000Z",
"dateUpdated": "2026-08-11T12:22:22.919Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2021-43323 (GCVE-0-2021-43323)
Vulnerability from nvd – Published: 2022-02-03 01:50 – Updated: 2026-08-11 12:22
VLAI
EPSS
VEX
Summary
An issue was discovered in UsbCoreDxe in Insyde InsydeH2O with kernel 5.5 before 05.51.45, 5.4 before 05.43.45, 5.3 before 05.35.45, 5.2 before 05.26.45, 5.1 before 05.16.45, and 5.0 before 05.08.45. An SMM callout vulnerability allows an attacker to hijack execution flow of code running in System Management Mode. Exploiting this issue could lead to escalating privileges to SMM.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
5 references
| URL | Tags |
|---|---|
| https://www.insyde.com/security-pledge | x_refsource_MISC |
| https://security.netapp.com/advisory/ntap-2022021… | x_refsource_CONFIRM |
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_CONFIRM |
| https://www.kb.cert.org/vuls/id/796611 | |
| https://cert-portal.siemens.com/productcert/html/… |
Impacted products
18 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | RUGGEDCOM APE1808 - BIOS |
Affected:
0 , < V1.0.202N
(custom)
|
|
| Siemens | SIMATIC Field PG M5 |
Affected:
0 , < V22.01.10
(custom)
|
|
| Siemens | SIMATIC Field PG M6 |
Affected:
0 , < V26.01.13
(custom)
|
|
| Siemens | SIMATIC IPC127E |
Affected:
0 , < V27.01.09
(custom)
|
|
| Siemens | SIMATIC IPC227G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC277G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC277G PRO |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC327G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC377G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC427E |
Affected:
0 , < V21.01.17
(custom)
|
|
| Siemens | SIMATIC IPC477E |
Affected:
0 , < V21.01.17
(custom)
|
|
| Siemens | SIMATIC IPC477E PRO |
Affected:
0 , < V21.01.17
(custom)
|
|
| Siemens | SIMATIC IPC627E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC IPC647E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC IPC677E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC IPC847E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC ITP1000 |
Affected:
0 , < V23.01.10
(custom)
|
|
| Siemens | SIPLUS IPC427E |
Affected:
0 , < V21.01.17
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2025-11-04T19:12:44.192Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.insyde.com/security-pledge"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://security.netapp.com/advisory/ntap-20220217-0013/"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
},
{
"url": "https://www.kb.cert.org/vuls/id/796611"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM APE1808 - BIOS",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.0.202N",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Field PG M5",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V22.01.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Field PG M6",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V26.01.13",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC127E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V27.01.09",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC227G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC277G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC\u00a0IPC277G PRO",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC327G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC377G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC427E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC477E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC477E PRO",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC627E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC647E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC677E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC847E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ITP1000",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V23.01.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS IPC427E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-08-11T12:22:19.420Z",
"orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
"shortName": "siemens-SADP"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-306654.html"
}
],
"x_adpType": "supplier"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered in UsbCoreDxe in Insyde InsydeH2O with kernel 5.5 before 05.51.45, 5.4 before 05.43.45, 5.3 before 05.35.45, 5.2 before 05.26.45, 5.1 before 05.16.45, and 5.0 before 05.08.45. An SMM callout vulnerability allows an attacker to hijack execution flow of code running in System Management Mode. Exploiting this issue could lead to escalating privileges to SMM."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-02-22T19:06:29.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.insyde.com/security-pledge"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://security.netapp.com/advisory/ntap-20220217-0013/"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2021-43323",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An issue was discovered in UsbCoreDxe in Insyde InsydeH2O with kernel 5.5 before 05.51.45, 5.4 before 05.43.45, 5.3 before 05.35.45, 5.2 before 05.26.45, 5.1 before 05.16.45, and 5.0 before 05.08.45. An SMM callout vulnerability allows an attacker to hijack execution flow of code running in System Management Mode. Exploiting this issue could lead to escalating privileges to SMM."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.insyde.com/security-pledge",
"refsource": "MISC",
"url": "https://www.insyde.com/security-pledge"
},
{
"name": "https://security.netapp.com/advisory/ntap-20220217-0013/",
"refsource": "CONFIRM",
"url": "https://security.netapp.com/advisory/ntap-20220217-0013/"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2021-43323",
"datePublished": "2022-02-03T01:50:01.000Z",
"dateReserved": "2021-11-03T00:00:00.000Z",
"dateUpdated": "2026-08-11T12:22:19.420Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2021-42554 (GCVE-0-2021-42554)
Vulnerability from nvd – Published: 2022-02-03 01:40 – Updated: 2026-08-11 12:22
VLAI
EPSS
VEX
Summary
An issue was discovered in Insyde InsydeH2O with Kernel 5.0 before 05.08.42, Kernel 5.1 before 05.16.42, Kernel 5.2 before 05.26.42, Kernel 5.3 before 05.35.42, Kernel 5.4 before 05.42.51, and Kernel 5.5 before 05.50.51. An SMM memory corruption vulnerability in FvbServicesRuntimeDxe allows a possible attacker to write fixed or predictable data to SMRAM. Exploiting this issue could lead to escalating privileges to SMM.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
6 references
| URL | Tags |
|---|---|
| https://www.insyde.com/security-pledge | x_refsource_MISC |
| https://www.insyde.com/security-pledge/SA-2022012 | x_refsource_MISC |
| https://security.netapp.com/advisory/ntap-2022021… | x_refsource_CONFIRM |
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_CONFIRM |
| https://www.kb.cert.org/vuls/id/796611 | |
| https://cert-portal.siemens.com/productcert/html/… |
Impacted products
18 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | RUGGEDCOM APE1808 - BIOS |
Affected:
0 , < V1.0.202N
(custom)
|
|
| Siemens | SIMATIC Field PG M5 |
Affected:
0 , < V22.01.10
(custom)
|
|
| Siemens | SIMATIC Field PG M6 |
Affected:
0 , < V26.01.13
(custom)
|
|
| Siemens | SIMATIC IPC127E |
Affected:
0 , < V27.01.09
(custom)
|
|
| Siemens | SIMATIC IPC227G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC277G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC277G PRO |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC327G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC377G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC427E |
Affected:
0 , < V21.01.17
(custom)
|
|
| Siemens | SIMATIC IPC477E |
Affected:
0 , < V21.01.17
(custom)
|
|
| Siemens | SIMATIC IPC477E PRO |
Affected:
0 , < V21.01.17
(custom)
|
|
| Siemens | SIMATIC IPC627E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC IPC647E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC IPC677E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC IPC847E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC ITP1000 |
Affected:
0 , < V23.01.10
(custom)
|
|
| Siemens | SIPLUS IPC427E |
Affected:
0 , < V21.01.17
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2025-11-04T19:12:43.116Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.insyde.com/security-pledge"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.insyde.com/security-pledge/SA-2022012"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://security.netapp.com/advisory/ntap-20220216-0007/"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
},
{
"url": "https://www.kb.cert.org/vuls/id/796611"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM APE1808 - BIOS",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.0.202N",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Field PG M5",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V22.01.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Field PG M6",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V26.01.13",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC127E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V27.01.09",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC227G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC277G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC\u00a0IPC277G PRO",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC327G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC377G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC427E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC477E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC477E PRO",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC627E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC647E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC677E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC847E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ITP1000",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V23.01.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS IPC427E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-08-11T12:22:18.229Z",
"orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
"shortName": "siemens-SADP"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-306654.html"
}
],
"x_adpType": "supplier"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered in Insyde InsydeH2O with Kernel 5.0 before 05.08.42, Kernel 5.1 before 05.16.42, Kernel 5.2 before 05.26.42, Kernel 5.3 before 05.35.42, Kernel 5.4 before 05.42.51, and Kernel 5.5 before 05.50.51. An SMM memory corruption vulnerability in FvbServicesRuntimeDxe allows a possible attacker to write fixed or predictable data to SMRAM. Exploiting this issue could lead to escalating privileges to SMM."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-02-22T19:06:40.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.insyde.com/security-pledge"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.insyde.com/security-pledge/SA-2022012"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://security.netapp.com/advisory/ntap-20220216-0007/"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2021-42554",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An issue was discovered in Insyde InsydeH2O with Kernel 5.0 before 05.08.42, Kernel 5.1 before 05.16.42, Kernel 5.2 before 05.26.42, Kernel 5.3 before 05.35.42, Kernel 5.4 before 05.42.51, and Kernel 5.5 before 05.50.51. An SMM memory corruption vulnerability in FvbServicesRuntimeDxe allows a possible attacker to write fixed or predictable data to SMRAM. Exploiting this issue could lead to escalating privileges to SMM."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.insyde.com/security-pledge",
"refsource": "MISC",
"url": "https://www.insyde.com/security-pledge"
},
{
"name": "https://www.insyde.com/security-pledge/SA-2022012",
"refsource": "MISC",
"url": "https://www.insyde.com/security-pledge/SA-2022012"
},
{
"name": "https://security.netapp.com/advisory/ntap-20220216-0007/",
"refsource": "CONFIRM",
"url": "https://security.netapp.com/advisory/ntap-20220216-0007/"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2021-42554",
"datePublished": "2022-02-03T01:40:56.000Z",
"dateReserved": "2021-10-18T00:00:00.000Z",
"dateUpdated": "2026-08-11T12:22:18.229Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2021-42113 (GCVE-0-2021-42113)
Vulnerability from nvd – Published: 2022-02-03 01:46 – Updated: 2026-08-11 12:22
VLAI
EPSS
VEX
Summary
An issue was discovered in StorageSecurityCommandDxe in Insyde InsydeH2O with Kernel 5.1 before 05.14.28, Kernel 5.2 before 05.24.28, and Kernel 5.3 before 05.32.25. An SMM callout vulnerability allows an attacker to hijack execution flow of code running in System Management Mode. Exploiting this issue could lead to escalating privileges to SMM.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
6 references
| URL | Tags |
|---|---|
| https://www.insyde.com/security-pledge | x_refsource_MISC |
| https://www.insyde.com/security-pledge/SA-2022008 | x_refsource_MISC |
| https://security.netapp.com/advisory/ntap-2022021… | x_refsource_CONFIRM |
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_CONFIRM |
| https://www.kb.cert.org/vuls/id/796611 | |
| https://cert-portal.siemens.com/productcert/html/… |
Impacted products
18 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | RUGGEDCOM APE1808 - BIOS |
Affected:
0 , < V1.0.202N
(custom)
|
|
| Siemens | SIMATIC Field PG M5 |
Affected:
0 , < V22.01.10
(custom)
|
|
| Siemens | SIMATIC Field PG M6 |
Affected:
0 , < V26.01.13
(custom)
|
|
| Siemens | SIMATIC IPC127E |
Affected:
0 , < V27.01.09
(custom)
|
|
| Siemens | SIMATIC IPC227G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC277G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC277G PRO |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC327G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC377G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC427E |
Affected:
0 , < V21.01.17
(custom)
|
|
| Siemens | SIMATIC IPC477E |
Affected:
0 , < V21.01.17
(custom)
|
|
| Siemens | SIMATIC IPC477E PRO |
Affected:
0 , < V21.01.17
(custom)
|
|
| Siemens | SIMATIC IPC627E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC IPC647E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC IPC677E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC IPC847E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC ITP1000 |
Affected:
0 , < V23.01.10
(custom)
|
|
| Siemens | SIPLUS IPC427E |
Affected:
0 , < V21.01.17
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2025-11-04T19:12:42.015Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.insyde.com/security-pledge"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.insyde.com/security-pledge/SA-2022008"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://security.netapp.com/advisory/ntap-20220216-0012/"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
},
{
"url": "https://www.kb.cert.org/vuls/id/796611"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM APE1808 - BIOS",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.0.202N",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Field PG M5",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V22.01.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Field PG M6",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V26.01.13",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC127E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V27.01.09",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC227G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC277G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC\u00a0IPC277G PRO",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC327G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC377G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC427E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC477E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC477E PRO",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC627E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC647E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC677E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC847E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ITP1000",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V23.01.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS IPC427E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-08-11T12:22:17.067Z",
"orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
"shortName": "siemens-SADP"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-306654.html"
}
],
"x_adpType": "supplier"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered in StorageSecurityCommandDxe in Insyde InsydeH2O with Kernel 5.1 before 05.14.28, Kernel 5.2 before 05.24.28, and Kernel 5.3 before 05.32.25. An SMM callout vulnerability allows an attacker to hijack execution flow of code running in System Management Mode. Exploiting this issue could lead to escalating privileges to SMM."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-02-22T19:06:49.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.insyde.com/security-pledge"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.insyde.com/security-pledge/SA-2022008"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://security.netapp.com/advisory/ntap-20220216-0012/"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2021-42113",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An issue was discovered in StorageSecurityCommandDxe in Insyde InsydeH2O with Kernel 5.1 before 05.14.28, Kernel 5.2 before 05.24.28, and Kernel 5.3 before 05.32.25. An SMM callout vulnerability allows an attacker to hijack execution flow of code running in System Management Mode. Exploiting this issue could lead to escalating privileges to SMM."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.insyde.com/security-pledge",
"refsource": "MISC",
"url": "https://www.insyde.com/security-pledge"
},
{
"name": "https://www.insyde.com/security-pledge/SA-2022008",
"refsource": "MISC",
"url": "https://www.insyde.com/security-pledge/SA-2022008"
},
{
"name": "https://security.netapp.com/advisory/ntap-20220216-0012/",
"refsource": "CONFIRM",
"url": "https://security.netapp.com/advisory/ntap-20220216-0012/"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2021-42113",
"datePublished": "2022-02-03T01:46:08.000Z",
"dateReserved": "2021-10-08T00:00:00.000Z",
"dateUpdated": "2026-08-11T12:22:17.067Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2021-42060 (GCVE-0-2021-42060)
Vulnerability from nvd – Published: 2022-02-03 01:27 – Updated: 2026-08-11 12:22
VLAI
EPSS
VEX
Summary
An issue was discovered in Insyde InsydeH2O Kernel 5.0 through 05.08.41, Kernel 5.1 through 05.16.41, Kernel 5.2 before 05.23.22, and Kernel 5.3 before 05.32.22. An Int15ServiceSmm SMM callout vulnerability allows an attacker to hijack execution flow of code running in System Management Mode. Exploiting this issue could lead to escalating privileges to SMM.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
6 references
| URL | Tags |
|---|---|
| https://www.insyde.com/security-pledge | x_refsource_MISC |
| https://www.insyde.com/security-pledge/SA-2022007 | x_refsource_MISC |
| https://security.netapp.com/advisory/ntap-2022021… | x_refsource_CONFIRM |
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_CONFIRM |
| https://www.kb.cert.org/vuls/id/796611 | |
| https://cert-portal.siemens.com/productcert/html/… |
Impacted products
18 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | RUGGEDCOM APE1808 - BIOS |
Affected:
0 , < V1.0.202N
(custom)
|
|
| Siemens | SIMATIC Field PG M5 |
Affected:
0 , < V22.01.10
(custom)
|
|
| Siemens | SIMATIC Field PG M6 |
Affected:
0 , < V26.01.13
(custom)
|
|
| Siemens | SIMATIC IPC127E |
Affected:
0 , < V27.01.09
(custom)
|
|
| Siemens | SIMATIC IPC227G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC277G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC277G PRO |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC327G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC377G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC427E |
Affected:
0 , < V21.01.17
(custom)
|
|
| Siemens | SIMATIC IPC477E |
Affected:
0 , < V21.01.17
(custom)
|
|
| Siemens | SIMATIC IPC477E PRO |
Affected:
0 , < V21.01.17
(custom)
|
|
| Siemens | SIMATIC IPC627E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC IPC647E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC IPC677E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC IPC847E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC ITP1000 |
Affected:
0 , < V23.01.10
(custom)
|
|
| Siemens | SIPLUS IPC427E |
Affected:
0 , < V21.01.17
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2025-11-04T19:12:40.921Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.insyde.com/security-pledge"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.insyde.com/security-pledge/SA-2022007"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://security.netapp.com/advisory/ntap-20220217-0015/"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
},
{
"url": "https://www.kb.cert.org/vuls/id/796611"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM APE1808 - BIOS",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.0.202N",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Field PG M5",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V22.01.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Field PG M6",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V26.01.13",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC127E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V27.01.09",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC227G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC277G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC\u00a0IPC277G PRO",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC327G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC377G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC427E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC477E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC477E PRO",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC627E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC647E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC677E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC847E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ITP1000",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V23.01.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS IPC427E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-08-11T12:22:15.909Z",
"orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
"shortName": "siemens-SADP"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-306654.html"
}
],
"x_adpType": "supplier"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered in Insyde InsydeH2O Kernel 5.0 through 05.08.41, Kernel 5.1 through 05.16.41, Kernel 5.2 before 05.23.22, and Kernel 5.3 before 05.32.22. An Int15ServiceSmm SMM callout vulnerability allows an attacker to hijack execution flow of code running in System Management Mode. Exploiting this issue could lead to escalating privileges to SMM."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-02-22T19:06:42.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.insyde.com/security-pledge"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.insyde.com/security-pledge/SA-2022007"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://security.netapp.com/advisory/ntap-20220217-0015/"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2021-42060",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An issue was discovered in Insyde InsydeH2O Kernel 5.0 through 05.08.41, Kernel 5.1 through 05.16.41, Kernel 5.2 before 05.23.22, and Kernel 5.3 before 05.32.22. An Int15ServiceSmm SMM callout vulnerability allows an attacker to hijack execution flow of code running in System Management Mode. Exploiting this issue could lead to escalating privileges to SMM."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.insyde.com/security-pledge",
"refsource": "MISC",
"url": "https://www.insyde.com/security-pledge"
},
{
"name": "https://www.insyde.com/security-pledge/SA-2022007",
"refsource": "MISC",
"url": "https://www.insyde.com/security-pledge/SA-2022007"
},
{
"name": "https://security.netapp.com/advisory/ntap-20220217-0015/",
"refsource": "CONFIRM",
"url": "https://security.netapp.com/advisory/ntap-20220217-0015/"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2021-42060",
"datePublished": "2022-02-03T01:27:34.000Z",
"dateReserved": "2021-10-07T00:00:00.000Z",
"dateUpdated": "2026-08-11T12:22:15.909Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2021-42059 (GCVE-0-2021-42059)
Vulnerability from nvd – Published: 2022-02-03 01:13 – Updated: 2026-08-11 12:22
VLAI
EPSS
VEX
Summary
An issue was discovered in Insyde InsydeH2O Kernel 5.0 before 05.08.41, Kernel 5.1 before 05.16.41, Kernel 5.2 before 05.26.41, Kernel 5.3 before 05.35.41, and Kernel 5.4 before 05.42.20. A stack-based buffer overflow leads toarbitrary code execution in UEFI DisplayTypeDxe DXE driver.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
6 references
| URL | Tags |
|---|---|
| https://www.insyde.com/security-pledge | x_refsource_MISC |
| https://www.insyde.com/security-pledge/SA-2022006 | x_refsource_MISC |
| https://security.netapp.com/advisory/ntap-2022021… | x_refsource_CONFIRM |
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_CONFIRM |
| https://www.kb.cert.org/vuls/id/796611 | |
| https://cert-portal.siemens.com/productcert/html/… |
Impacted products
18 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | RUGGEDCOM APE1808 - BIOS |
Affected:
0 , < V1.0.202N
(custom)
|
|
| Siemens | SIMATIC Field PG M5 |
Affected:
0 , < V22.01.10
(custom)
|
|
| Siemens | SIMATIC Field PG M6 |
Affected:
0 , < V26.01.13
(custom)
|
|
| Siemens | SIMATIC IPC127E |
Affected:
0 , < V27.01.09
(custom)
|
|
| Siemens | SIMATIC IPC227G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC277G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC277G PRO |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC327G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC377G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC427E |
Affected:
0 , < V21.01.17
(custom)
|
|
| Siemens | SIMATIC IPC477E |
Affected:
0 , < V21.01.17
(custom)
|
|
| Siemens | SIMATIC IPC477E PRO |
Affected:
0 , < V21.01.17
(custom)
|
|
| Siemens | SIMATIC IPC627E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC IPC647E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC IPC677E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC IPC847E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC ITP1000 |
Affected:
0 , < V23.01.10
(custom)
|
|
| Siemens | SIPLUS IPC427E |
Affected:
0 , < V21.01.17
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2025-11-04T19:12:39.726Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.insyde.com/security-pledge"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.insyde.com/security-pledge/SA-2022006"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://security.netapp.com/advisory/ntap-20220216-0008/"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
},
{
"url": "https://www.kb.cert.org/vuls/id/796611"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM APE1808 - BIOS",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.0.202N",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Field PG M5",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V22.01.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Field PG M6",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V26.01.13",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC127E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V27.01.09",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC227G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC277G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC\u00a0IPC277G PRO",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC327G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC377G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC427E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC477E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC477E PRO",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC627E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC647E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC677E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC847E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ITP1000",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V23.01.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS IPC427E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-08-11T12:22:14.617Z",
"orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
"shortName": "siemens-SADP"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-306654.html"
}
],
"x_adpType": "supplier"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered in Insyde InsydeH2O Kernel 5.0 before 05.08.41, Kernel 5.1 before 05.16.41, Kernel 5.2 before 05.26.41, Kernel 5.3 before 05.35.41, and Kernel 5.4 before 05.42.20. A stack-based buffer overflow leads toarbitrary code execution in UEFI DisplayTypeDxe DXE driver."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-02-22T19:06:27.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.insyde.com/security-pledge"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.insyde.com/security-pledge/SA-2022006"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://security.netapp.com/advisory/ntap-20220216-0008/"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2021-42059",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An issue was discovered in Insyde InsydeH2O Kernel 5.0 before 05.08.41, Kernel 5.1 before 05.16.41, Kernel 5.2 before 05.26.41, Kernel 5.3 before 05.35.41, and Kernel 5.4 before 05.42.20. A stack-based buffer overflow leads toarbitrary code execution in UEFI DisplayTypeDxe DXE driver."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.insyde.com/security-pledge",
"refsource": "MISC",
"url": "https://www.insyde.com/security-pledge"
},
{
"name": "https://www.insyde.com/security-pledge/SA-2022006",
"refsource": "MISC",
"url": "https://www.insyde.com/security-pledge/SA-2022006"
},
{
"name": "https://security.netapp.com/advisory/ntap-20220216-0008/",
"refsource": "CONFIRM",
"url": "https://security.netapp.com/advisory/ntap-20220216-0008/"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2021-42059",
"datePublished": "2022-02-03T01:13:47.000Z",
"dateReserved": "2021-10-07T00:00:00.000Z",
"dateUpdated": "2026-08-11T12:22:14.617Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2021-41841 (GCVE-0-2021-41841)
Vulnerability from nvd – Published: 2022-02-03 01:04 – Updated: 2026-08-11 12:22
VLAI
EPSS
VEX
Summary
An issue was discovered in AhciBusDxe in the kernel 5.0 through 5.5 in Insyde InsydeH2O. There is an SMM callout that allows an attacker to access the System Management Mode and execute arbitrary code. This occurs because of Inclusion of Functionality from an Untrusted Control Sphere.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
6 references
| URL | Tags |
|---|---|
| https://www.insyde.com/security-pledge | x_refsource_MISC |
| https://www.insyde.com/security-pledge/SA-2022019 | x_refsource_MISC |
| https://security.netapp.com/advisory/ntap-2022021… | x_refsource_CONFIRM |
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_CONFIRM |
| https://www.kb.cert.org/vuls/id/796611 | |
| https://cert-portal.siemens.com/productcert/html/… |
Impacted products
18 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | RUGGEDCOM APE1808 - BIOS |
Affected:
0 , < V1.0.202N
(custom)
|
|
| Siemens | SIMATIC Field PG M5 |
Affected:
0 , < V22.01.10
(custom)
|
|
| Siemens | SIMATIC Field PG M6 |
Affected:
0 , < V26.01.13
(custom)
|
|
| Siemens | SIMATIC IPC127E |
Affected:
0 , < V27.01.09
(custom)
|
|
| Siemens | SIMATIC IPC227G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC277G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC277G PRO |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC327G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC377G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC427E |
Affected:
0 , < V21.01.17
(custom)
|
|
| Siemens | SIMATIC IPC477E |
Affected:
0 , < V21.01.17
(custom)
|
|
| Siemens | SIMATIC IPC477E PRO |
Affected:
0 , < V21.01.17
(custom)
|
|
| Siemens | SIMATIC IPC627E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC IPC647E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC IPC677E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC IPC847E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC ITP1000 |
Affected:
0 , < V23.01.10
(custom)
|
|
| Siemens | SIPLUS IPC427E |
Affected:
0 , < V21.01.17
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2025-11-04T19:12:38.619Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.insyde.com/security-pledge"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.insyde.com/security-pledge/SA-2022019"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://security.netapp.com/advisory/ntap-20220217-0012/"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
},
{
"url": "https://www.kb.cert.org/vuls/id/796611"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM APE1808 - BIOS",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.0.202N",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Field PG M5",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V22.01.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Field PG M6",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V26.01.13",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC127E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V27.01.09",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC227G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC277G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC\u00a0IPC277G PRO",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC327G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC377G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC427E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC477E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC477E PRO",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC627E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC647E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC677E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC847E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ITP1000",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V23.01.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS IPC427E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-08-11T12:22:13.467Z",
"orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
"shortName": "siemens-SADP"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-306654.html"
}
],
"x_adpType": "supplier"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered in AhciBusDxe in the kernel 5.0 through 5.5 in Insyde InsydeH2O. There is an SMM callout that allows an attacker to access the System Management Mode and execute arbitrary code. This occurs because of Inclusion of Functionality from an Untrusted Control Sphere."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-02-22T19:06:23.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.insyde.com/security-pledge"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.insyde.com/security-pledge/SA-2022019"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://security.netapp.com/advisory/ntap-20220217-0012/"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2021-41841",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An issue was discovered in AhciBusDxe in the kernel 5.0 through 5.5 in Insyde InsydeH2O. There is an SMM callout that allows an attacker to access the System Management Mode and execute arbitrary code. This occurs because of Inclusion of Functionality from an Untrusted Control Sphere."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.insyde.com/security-pledge",
"refsource": "MISC",
"url": "https://www.insyde.com/security-pledge"
},
{
"name": "https://www.insyde.com/security-pledge/SA-2022019",
"refsource": "MISC",
"url": "https://www.insyde.com/security-pledge/SA-2022019"
},
{
"name": "https://security.netapp.com/advisory/ntap-20220217-0012/",
"refsource": "CONFIRM",
"url": "https://security.netapp.com/advisory/ntap-20220217-0012/"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2021-41841",
"datePublished": "2022-02-03T01:04:57.000Z",
"dateReserved": "2021-10-01T00:00:00.000Z",
"dateUpdated": "2026-08-11T12:22:13.467Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2021-41840 (GCVE-0-2021-41840)
Vulnerability from nvd – Published: 2022-02-03 01:20 – Updated: 2026-08-11 12:22
VLAI
EPSS
VEX
Summary
An issue was discovered in NvmExpressDxe in the kernel 5.0 through 5.5 in Insyde InsydeH2O. There is an SMM callout that allows an attacker to access the System Management Mode and execute arbitrary code. This occurs because of Inclusion of Functionality from an Untrusted Control Sphere.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
6 references
| URL | Tags |
|---|---|
| https://www.insyde.com/security-pledge | x_refsource_MISC |
| https://www.insyde.com/security-pledge/SA-2022018 | x_refsource_MISC |
| https://security.netapp.com/advisory/ntap-2022021… | x_refsource_CONFIRM |
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_CONFIRM |
| https://www.kb.cert.org/vuls/id/796611 | |
| https://cert-portal.siemens.com/productcert/html/… |
Impacted products
17 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | SIMATIC Field PG M5 |
Affected:
0 , < V22.01.10
(custom)
|
|
| Siemens | SIMATIC Field PG M6 |
Affected:
0 , < V26.01.13
(custom)
|
|
| Siemens | SIMATIC IPC127E |
Affected:
0 , < V27.01.09
(custom)
|
|
| Siemens | SIMATIC IPC227G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC277G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC277G PRO |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC327G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC377G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC427E |
Affected:
0 , < V21.01.17
(custom)
|
|
| Siemens | SIMATIC IPC477E |
Affected:
0 , < V21.01.17
(custom)
|
|
| Siemens | SIMATIC IPC477E PRO |
Affected:
0 , < V21.01.17
(custom)
|
|
| Siemens | SIMATIC IPC627E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC IPC647E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC IPC677E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC IPC847E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC ITP1000 |
Affected:
0 , < V23.01.10
(custom)
|
|
| Siemens | SIPLUS IPC427E |
Affected:
0 , < V21.01.17
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2025-11-04T19:12:37.499Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.insyde.com/security-pledge"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.insyde.com/security-pledge/SA-2022018"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://security.netapp.com/advisory/ntap-20220217-0014/"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
},
{
"url": "https://www.kb.cert.org/vuls/id/796611"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC Field PG M5",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V22.01.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Field PG M6",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V26.01.13",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC127E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V27.01.09",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC227G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC277G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC\u00a0IPC277G PRO",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC327G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC377G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC427E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC477E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC477E PRO",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC627E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC647E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC677E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC847E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ITP1000",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V23.01.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS IPC427E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-08-11T12:22:12.302Z",
"orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
"shortName": "siemens-SADP"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-306654.html"
}
],
"x_adpType": "supplier"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered in NvmExpressDxe in the kernel 5.0 through 5.5 in Insyde InsydeH2O. There is an SMM callout that allows an attacker to access the System Management Mode and execute arbitrary code. This occurs because of Inclusion of Functionality from an Untrusted Control Sphere."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-02-22T19:06:58.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.insyde.com/security-pledge"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.insyde.com/security-pledge/SA-2022018"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://security.netapp.com/advisory/ntap-20220217-0014/"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2021-41840",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An issue was discovered in NvmExpressDxe in the kernel 5.0 through 5.5 in Insyde InsydeH2O. There is an SMM callout that allows an attacker to access the System Management Mode and execute arbitrary code. This occurs because of Inclusion of Functionality from an Untrusted Control Sphere."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.insyde.com/security-pledge",
"refsource": "MISC",
"url": "https://www.insyde.com/security-pledge"
},
{
"name": "https://www.insyde.com/security-pledge/SA-2022018",
"refsource": "MISC",
"url": "https://www.insyde.com/security-pledge/SA-2022018"
},
{
"name": "https://security.netapp.com/advisory/ntap-20220217-0014/",
"refsource": "CONFIRM",
"url": "https://security.netapp.com/advisory/ntap-20220217-0014/"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2021-41840",
"datePublished": "2022-02-03T01:20:07.000Z",
"dateReserved": "2021-10-01T00:00:00.000Z",
"dateUpdated": "2026-08-11T12:22:12.302Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2021-41839 (GCVE-0-2021-41839)
Vulnerability from nvd – Published: 2022-02-03 01:37 – Updated: 2026-08-11 12:22
VLAI
EPSS
VEX
Summary
An issue was discovered in NvmExpressDxe in the kernel 5.0 through 5.5 in Insyde InsydeH2O. Because of an Untrusted Pointer Dereference that causes SMM memory corruption, an attacker may be able to write fixed or predictable data to SMRAM. Exploiting this issue could lead to escalating privileges to SMM.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
6 references
| URL | Tags |
|---|---|
| https://www.insyde.com/security-pledge | x_refsource_MISC |
| https://www.insyde.com/security-pledge/SA-2022020 | x_refsource_MISC |
| https://security.netapp.com/advisory/ntap-2022021… | x_refsource_CONFIRM |
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_CONFIRM |
| https://www.kb.cert.org/vuls/id/796611 | |
| https://cert-portal.siemens.com/productcert/html/… |
Impacted products
18 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | RUGGEDCOM APE1808 - BIOS |
Affected:
0 , < V1.0.202N
(custom)
|
|
| Siemens | SIMATIC Field PG M5 |
Affected:
0 , < V22.01.10
(custom)
|
|
| Siemens | SIMATIC Field PG M6 |
Affected:
0 , < V26.01.13
(custom)
|
|
| Siemens | SIMATIC IPC127E |
Affected:
0 , < V27.01.09
(custom)
|
|
| Siemens | SIMATIC IPC227G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC277G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC277G PRO |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC327G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC377G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC427E |
Affected:
0 , < V21.01.17
(custom)
|
|
| Siemens | SIMATIC IPC477E |
Affected:
0 , < V21.01.17
(custom)
|
|
| Siemens | SIMATIC IPC477E PRO |
Affected:
0 , < V21.01.17
(custom)
|
|
| Siemens | SIMATIC IPC627E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC IPC647E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC IPC677E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC IPC847E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC ITP1000 |
Affected:
0 , < V23.01.10
(custom)
|
|
| Siemens | SIPLUS IPC427E |
Affected:
0 , < V21.01.17
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2025-11-04T19:12:36.407Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.insyde.com/security-pledge"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.insyde.com/security-pledge/SA-2022020"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://security.netapp.com/advisory/ntap-20220217-0016/"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
},
{
"url": "https://www.kb.cert.org/vuls/id/796611"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM APE1808 - BIOS",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.0.202N",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Field PG M5",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V22.01.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Field PG M6",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V26.01.13",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC127E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V27.01.09",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC227G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC277G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC\u00a0IPC277G PRO",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC327G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC377G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC427E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC477E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC477E PRO",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC627E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC647E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC677E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC847E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ITP1000",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V23.01.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS IPC427E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-08-11T12:22:11.112Z",
"orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
"shortName": "siemens-SADP"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-306654.html"
}
],
"x_adpType": "supplier"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered in NvmExpressDxe in the kernel 5.0 through 5.5 in Insyde InsydeH2O. Because of an Untrusted Pointer Dereference that causes SMM memory corruption, an attacker may be able to write fixed or predictable data to SMRAM. Exploiting this issue could lead to escalating privileges to SMM."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-02-22T19:06:25.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.insyde.com/security-pledge"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.insyde.com/security-pledge/SA-2022020"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://security.netapp.com/advisory/ntap-20220217-0016/"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2021-41839",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An issue was discovered in NvmExpressDxe in the kernel 5.0 through 5.5 in Insyde InsydeH2O. Because of an Untrusted Pointer Dereference that causes SMM memory corruption, an attacker may be able to write fixed or predictable data to SMRAM. Exploiting this issue could lead to escalating privileges to SMM."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.insyde.com/security-pledge",
"refsource": "MISC",
"url": "https://www.insyde.com/security-pledge"
},
{
"name": "https://www.insyde.com/security-pledge/SA-2022020",
"refsource": "MISC",
"url": "https://www.insyde.com/security-pledge/SA-2022020"
},
{
"name": "https://security.netapp.com/advisory/ntap-20220217-0016/",
"refsource": "CONFIRM",
"url": "https://security.netapp.com/advisory/ntap-20220217-0016/"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2021-41839",
"datePublished": "2022-02-03T01:37:10.000Z",
"dateReserved": "2021-10-01T00:00:00.000Z",
"dateUpdated": "2026-08-11T12:22:11.112Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2021-41838 (GCVE-0-2021-41838)
Vulnerability from nvd – Published: 2022-02-03 01:43 – Updated: 2026-08-11 12:22
VLAI
EPSS
VEX
Summary
An issue was discovered in SdHostDriver in the kernel 5.0 through 5.5 in Insyde InsydeH2O. There is an SMM callout that allows an attacker to access the System Management Mode and execute arbitrary code. This occurs because of a Numeric Range Comparison Without a Minimum Check.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
6 references
| URL | Tags |
|---|---|
| https://www.insyde.com/security-pledge | x_refsource_MISC |
| https://www.insyde.com/security-pledge/SA-2022023 | x_refsource_MISC |
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_CONFIRM |
| https://security.netapp.com/advisory/ntap-2022022… | x_refsource_CONFIRM |
| https://www.kb.cert.org/vuls/id/796611 | |
| https://cert-portal.siemens.com/productcert/html/… |
Impacted products
18 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | RUGGEDCOM APE1808 - BIOS |
Affected:
0 , < V1.0.202N
(custom)
|
|
| Siemens | SIMATIC Field PG M5 |
Affected:
0 , < V22.01.10
(custom)
|
|
| Siemens | SIMATIC Field PG M6 |
Affected:
0 , < V26.01.13
(custom)
|
|
| Siemens | SIMATIC IPC127E |
Affected:
0 , < V27.01.09
(custom)
|
|
| Siemens | SIMATIC IPC227G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC277G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC277G PRO |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC327G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC377G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC427E |
Affected:
0 , < V21.01.17
(custom)
|
|
| Siemens | SIMATIC IPC477E |
Affected:
0 , < V21.01.17
(custom)
|
|
| Siemens | SIMATIC IPC477E PRO |
Affected:
0 , < V21.01.17
(custom)
|
|
| Siemens | SIMATIC IPC627E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC IPC647E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC IPC677E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC IPC847E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC ITP1000 |
Affected:
0 , < V23.01.10
(custom)
|
|
| Siemens | SIPLUS IPC427E |
Affected:
0 , < V21.01.17
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2025-11-04T19:12:35.317Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.insyde.com/security-pledge"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.insyde.com/security-pledge/SA-2022023"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://security.netapp.com/advisory/ntap-20220222-0001/"
},
{
"url": "https://www.kb.cert.org/vuls/id/796611"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM APE1808 - BIOS",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.0.202N",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Field PG M5",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V22.01.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Field PG M6",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V26.01.13",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC127E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V27.01.09",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC227G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC277G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC\u00a0IPC277G PRO",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC327G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC377G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC427E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC477E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC477E PRO",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC627E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC647E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC677E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC847E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ITP1000",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V23.01.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS IPC427E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-08-11T12:22:09.947Z",
"orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
"shortName": "siemens-SADP"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-306654.html"
}
],
"x_adpType": "supplier"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered in SdHostDriver in the kernel 5.0 through 5.5 in Insyde InsydeH2O. There is an SMM callout that allows an attacker to access the System Management Mode and execute arbitrary code. This occurs because of a Numeric Range Comparison Without a Minimum Check."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-02-23T15:06:23.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.insyde.com/security-pledge"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.insyde.com/security-pledge/SA-2022023"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://security.netapp.com/advisory/ntap-20220222-0001/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2021-41838",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An issue was discovered in SdHostDriver in the kernel 5.0 through 5.5 in Insyde InsydeH2O. There is an SMM callout that allows an attacker to access the System Management Mode and execute arbitrary code. This occurs because of a Numeric Range Comparison Without a Minimum Check."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.insyde.com/security-pledge",
"refsource": "MISC",
"url": "https://www.insyde.com/security-pledge"
},
{
"name": "https://www.insyde.com/security-pledge/SA-2022023",
"refsource": "MISC",
"url": "https://www.insyde.com/security-pledge/SA-2022023"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
},
{
"name": "https://security.netapp.com/advisory/ntap-20220222-0001/",
"refsource": "CONFIRM",
"url": "https://security.netapp.com/advisory/ntap-20220222-0001/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2021-41838",
"datePublished": "2022-02-03T01:43:30.000Z",
"dateReserved": "2021-10-01T00:00:00.000Z",
"dateUpdated": "2026-08-11T12:22:09.947Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2021-41837 (GCVE-0-2021-41837)
Vulnerability from nvd – Published: 2022-02-03 01:23 – Updated: 2026-08-11 12:22
VLAI
EPSS
VEX
Summary
An issue was discovered in AhciBusDxe in the kernel 5.0 through 5.5 in Insyde InsydeH2O. Because of an Untrusted Pointer Dereference that causes SMM memory corruption, an attacker may be able to write fixed or predictable data to SMRAM. Exploiting this issue could lead to escalating privileges to SMM.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
6 references
| URL | Tags |
|---|---|
| https://www.insyde.com/security-pledge | x_refsource_MISC |
| https://www.insyde.com/security-pledge/SA-2022024 | x_refsource_MISC |
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_CONFIRM |
| https://security.netapp.com/advisory/ntap-2022022… | x_refsource_CONFIRM |
| https://www.kb.cert.org/vuls/id/796611 | |
| https://cert-portal.siemens.com/productcert/html/… |
Impacted products
18 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | RUGGEDCOM APE1808 - BIOS |
Affected:
0 , < V1.0.202N
(custom)
|
|
| Siemens | SIMATIC Field PG M5 |
Affected:
0 , < V22.01.10
(custom)
|
|
| Siemens | SIMATIC Field PG M6 |
Affected:
0 , < V26.01.13
(custom)
|
|
| Siemens | SIMATIC IPC127E |
Affected:
0 , < V27.01.09
(custom)
|
|
| Siemens | SIMATIC IPC227G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC277G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC277G PRO |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC327G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC377G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC427E |
Affected:
0 , < V21.01.17
(custom)
|
|
| Siemens | SIMATIC IPC477E |
Affected:
0 , < V21.01.17
(custom)
|
|
| Siemens | SIMATIC IPC477E PRO |
Affected:
0 , < V21.01.17
(custom)
|
|
| Siemens | SIMATIC IPC627E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC IPC647E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC IPC677E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC IPC847E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC ITP1000 |
Affected:
0 , < V23.01.10
(custom)
|
|
| Siemens | SIPLUS IPC427E |
Affected:
0 , < V21.01.17
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2025-11-04T19:12:34.238Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.insyde.com/security-pledge"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.insyde.com/security-pledge/SA-2022024"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://security.netapp.com/advisory/ntap-20220222-0003/"
},
{
"url": "https://www.kb.cert.org/vuls/id/796611"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM APE1808 - BIOS",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.0.202N",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Field PG M5",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V22.01.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Field PG M6",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V26.01.13",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC127E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V27.01.09",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC227G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC277G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC\u00a0IPC277G PRO",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC327G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC377G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC427E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC477E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC477E PRO",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC627E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC647E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC677E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC847E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ITP1000",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V23.01.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS IPC427E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-08-11T12:22:08.782Z",
"orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
"shortName": "siemens-SADP"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-306654.html"
}
],
"x_adpType": "supplier"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered in AhciBusDxe in the kernel 5.0 through 5.5 in Insyde InsydeH2O. Because of an Untrusted Pointer Dereference that causes SMM memory corruption, an attacker may be able to write fixed or predictable data to SMRAM. Exploiting this issue could lead to escalating privileges to SMM."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-02-23T15:06:18.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.insyde.com/security-pledge"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.insyde.com/security-pledge/SA-2022024"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://security.netapp.com/advisory/ntap-20220222-0003/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2021-41837",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An issue was discovered in AhciBusDxe in the kernel 5.0 through 5.5 in Insyde InsydeH2O. Because of an Untrusted Pointer Dereference that causes SMM memory corruption, an attacker may be able to write fixed or predictable data to SMRAM. Exploiting this issue could lead to escalating privileges to SMM."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.insyde.com/security-pledge",
"refsource": "MISC",
"url": "https://www.insyde.com/security-pledge"
},
{
"name": "https://www.insyde.com/security-pledge/SA-2022024",
"refsource": "MISC",
"url": "https://www.insyde.com/security-pledge/SA-2022024"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
},
{
"name": "https://security.netapp.com/advisory/ntap-20220222-0003/",
"refsource": "CONFIRM",
"url": "https://security.netapp.com/advisory/ntap-20220222-0003/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2021-41837",
"datePublished": "2022-02-03T01:23:39.000Z",
"dateReserved": "2021-10-01T00:00:00.000Z",
"dateUpdated": "2026-08-11T12:22:08.782Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2021-33627 (GCVE-0-2021-33627)
Vulnerability from nvd – Published: 2022-02-03 01:30 – Updated: 2026-08-11 12:22
VLAI
EPSS
VEX
Summary
An issue was discovered in Insyde InsydeH2O Kernel 5.0 before 05.09.11, 5.1 before 05.17.11, 5.2 before 05.27.11, 5.3 before 05.36.11, 5.4 before 05.44.11, and 5.5 before 05.52.11 affecting FwBlockServiceSmm. Software SMI services that use the Communicate() function of the EFI_SMM_COMMUNICATION_PROTOCOL do not check whether the address of the buffer is valid, which allows use of SMRAM, MMIO, or OS kernel addresses.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
6 references
Impacted products
18 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | RUGGEDCOM APE1808 - BIOS |
Affected:
0 , < V1.0.202N
(custom)
|
|
| Siemens | SIMATIC Field PG M5 |
Affected:
0 , < V22.01.10
(custom)
|
|
| Siemens | SIMATIC Field PG M6 |
Affected:
0 , < V26.01.13
(custom)
|
|
| Siemens | SIMATIC IPC127E |
Affected:
0 , < V27.01.09
(custom)
|
|
| Siemens | SIMATIC IPC227G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC277G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC277G PRO |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC327G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC377G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC427E |
Affected:
0 , < V21.01.17
(custom)
|
|
| Siemens | SIMATIC IPC477E |
Affected:
0 , < V21.01.17
(custom)
|
|
| Siemens | SIMATIC IPC477E PRO |
Affected:
0 , < V21.01.17
(custom)
|
|
| Siemens | SIMATIC IPC627E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC IPC647E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC IPC677E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC IPC847E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC ITP1000 |
Affected:
0 , < V23.01.10
(custom)
|
|
| Siemens | SIPLUS IPC427E |
Affected:
0 , < V21.01.17
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2025-11-04T19:12:32.043Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.insyde.com/security-pledge"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.insyde.com/security-pledge/SA-2022022"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://security.netapp.com/advisory/ntap-20220222-0002/"
},
{
"url": "https://www.kb.cert.org/vuls/id/796611"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM APE1808 - BIOS",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.0.202N",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Field PG M5",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V22.01.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Field PG M6",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V26.01.13",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC127E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V27.01.09",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC227G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC277G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC\u00a0IPC277G PRO",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC327G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC377G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC427E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC477E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC477E PRO",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC627E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC647E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC677E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC847E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ITP1000",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V23.01.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS IPC427E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-08-11T12:22:07.040Z",
"orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
"shortName": "siemens-SADP"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-306654.html"
}
],
"x_adpType": "supplier"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered in Insyde InsydeH2O Kernel 5.0 before 05.09.11, 5.1 before 05.17.11, 5.2 before 05.27.11, 5.3 before 05.36.11, 5.4 before 05.44.11, and 5.5 before 05.52.11 affecting FwBlockServiceSmm. Software SMI services that use the Communicate() function of the EFI_SMM_COMMUNICATION_PROTOCOL do not check whether the address of the buffer is valid, which allows use of SMRAM, MMIO, or OS kernel addresses."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-07-22T16:50:10.835Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://www.insyde.com/security-pledge"
},
{
"url": "https://www.insyde.com/security-pledge/SA-2022022"
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
},
{
"url": "https://security.netapp.com/advisory/ntap-20220222-0002/"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2021-33627",
"datePublished": "2022-02-03T01:30:36.000Z",
"dateReserved": "2021-05-28T00:00:00.000Z",
"dateUpdated": "2026-08-11T12:22:07.040Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2021-33625 (GCVE-0-2021-33625)
Vulnerability from nvd – Published: 2022-02-03 01:55 – Updated: 2026-08-11 12:22
VLAI
EPSS
VEX
Summary
An issue was discovered in Kernel 5.x in Insyde InsydeH2O, affecting HddPassword. Software SMI services that use the Communicate() function of the EFI_SMM_COMMUNICATION_PROTOCOL do not check whether the address of the buffer is valid, which allows use of SMRAM, MMIO, or OS kernel addresses.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
6 references
| URL | Tags |
|---|---|
| https://www.insyde.com/security-pledge | x_refsource_MISC |
| https://www.insyde.com/security-pledge/SA-2022014 | x_refsource_MISC |
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_CONFIRM |
| https://security.netapp.com/advisory/ntap-2022022… | x_refsource_CONFIRM |
| https://www.kb.cert.org/vuls/id/796611 | |
| https://cert-portal.siemens.com/productcert/html/… |
Impacted products
18 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | RUGGEDCOM APE1808 - BIOS |
Affected:
0 , < V1.0.202N
(custom)
|
|
| Siemens | SIMATIC Field PG M5 |
Affected:
0 , < V22.01.10
(custom)
|
|
| Siemens | SIMATIC Field PG M6 |
Affected:
0 , < V26.01.13
(custom)
|
|
| Siemens | SIMATIC IPC127E |
Affected:
0 , < V27.01.09
(custom)
|
|
| Siemens | SIMATIC IPC227G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC277G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC277G PRO |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC327G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC377G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC427E |
Affected:
0 , < V21.01.17
(custom)
|
|
| Siemens | SIMATIC IPC477E |
Affected:
0 , < V21.01.17
(custom)
|
|
| Siemens | SIMATIC IPC477E PRO |
Affected:
0 , < V21.01.17
(custom)
|
|
| Siemens | SIMATIC IPC627E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC IPC647E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC IPC677E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC IPC847E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC ITP1000 |
Affected:
0 , < V23.01.10
(custom)
|
|
| Siemens | SIPLUS IPC427E |
Affected:
0 , < V21.01.17
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2025-11-04T19:12:29.871Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.insyde.com/security-pledge"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.insyde.com/security-pledge/SA-2022014"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://security.netapp.com/advisory/ntap-20220222-0004/"
},
{
"url": "https://www.kb.cert.org/vuls/id/796611"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM APE1808 - BIOS",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.0.202N",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Field PG M5",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V22.01.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Field PG M6",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V26.01.13",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC127E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V27.01.09",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC227G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC277G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC\u00a0IPC277G PRO",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC327G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC377G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC427E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC477E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC477E PRO",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC627E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC647E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC677E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC847E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ITP1000",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V23.01.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS IPC427E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-08-11T12:22:04.521Z",
"orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
"shortName": "siemens-SADP"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-306654.html"
}
],
"x_adpType": "supplier"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered in Kernel 5.x in Insyde InsydeH2O, affecting HddPassword. Software SMI services that use the Communicate() function of the EFI_SMM_COMMUNICATION_PROTOCOL do not check whether the address of the buffer is valid, which allows use of SMRAM, MMIO, or OS kernel addresses."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-02-23T15:06:25.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.insyde.com/security-pledge"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.insyde.com/security-pledge/SA-2022014"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://security.netapp.com/advisory/ntap-20220222-0004/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2021-33625",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An issue was discovered in Kernel 5.x in Insyde InsydeH2O, affecting HddPassword. Software SMI services that use the Communicate() function of the EFI_SMM_COMMUNICATION_PROTOCOL do not check whether the address of the buffer is valid, which allows use of SMRAM, MMIO, or OS kernel addresses."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.insyde.com/security-pledge",
"refsource": "MISC",
"url": "https://www.insyde.com/security-pledge"
},
{
"name": "https://www.insyde.com/security-pledge/SA-2022014",
"refsource": "MISC",
"url": "https://www.insyde.com/security-pledge/SA-2022014"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
},
{
"name": "https://security.netapp.com/advisory/ntap-20220222-0004/",
"refsource": "CONFIRM",
"url": "https://security.netapp.com/advisory/ntap-20220222-0004/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2021-33625",
"datePublished": "2022-02-03T01:55:10.000Z",
"dateReserved": "2021-05-28T00:00:00.000Z",
"dateUpdated": "2026-08-11T12:22:04.521Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-2884 (GCVE-0-2025-2884)
Vulnerability from cvelistv5 – Published: 2025-06-10 17:29 – Updated: 2026-08-11 12:22
VLAI
EPSS
VEX
Title
Out-of-Bounds read vulnerability in TCG TPM2.0 reference implementation
Summary
TCG TPM2.0 Reference implementation's CryptHmacSign helper function is vulnerable to Out-of-Bounds read due to the lack of validation the signature scheme with the signature key's algorithm. See Errata Revision 1.83 and advisory TCGVRT0009 for TCG standard TPM2.0
Severity
6.6 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
Mission & Well-being: medium
certcc
Decision recorded 2025-06-13 17:22 UTC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-06-13 01:41 UTC
CWE
- CWE-125 Out-of-bounds Read
- CWE-125 - Out-of-bounds Read
Assigner
References
8 references
Impacted products
25 products
| Vendor | Product | Version | |
|---|---|---|---|
| Trusted Computing Group | TPM2.0 |
Affected:
0 , < 1.83
(custom)
|
|
| Siemens | SIMATIC CN 4100 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIMATIC Field PG M5 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIMATIC Field PG M6 |
Affected:
0 , < V26.01.14
(custom)
|
|
| Siemens | SIMATIC IPC BX-32A |
Affected:
0 , < V29.01.09
(custom)
|
|
| Siemens | SIMATIC IPC BX-39A |
Affected:
0 , < V29.01.09
(custom)
|
|
| Siemens | SIMATIC IPC BX-56A |
Affected:
0 , < V32.01.09
(custom)
|
|
| Siemens | SIMATIC IPC BX-59A |
Affected:
0 , < V32.01.09
(custom)
|
|
| Siemens | SIMATIC IPC MD-57A |
Affected:
0 , < V30.01.10
(custom)
|
|
| Siemens | SIMATIC IPC PX-32A |
Affected:
0 , < V29.01.09
(custom)
|
|
| Siemens | SIMATIC IPC PX-39A |
Affected:
0 , < V29.01.09
(custom)
|
|
| Siemens | SIMATIC IPC PX-39A PRO |
Affected:
0 , < V29.01.09
(custom)
|
|
| Siemens | SIMATIC IPC RW-528A |
Affected:
0 , < V34.01.02
(custom)
|
|
| Siemens | SIMATIC IPC RW-548A |
Affected:
0 , < V34.01.02
(custom)
|
|
| Siemens | SIMATIC IPC227E |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIMATIC IPC277E |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIMATIC IPC427E |
Affected:
0 , < V21.01.20
(custom)
|
|
| Siemens | SIMATIC IPC477E |
Affected:
0 , < V21.01.20
(custom)
|
|
| Siemens | SIMATIC IPC477E PRO |
Affected:
0 , < V21.01.20
(custom)
|
|
| Siemens | SIMATIC IPC627E |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIMATIC IPC647E |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIMATIC IPC677E |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIMATIC IPC847E |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIMATIC ITP1000 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIPLUS IPC427E |
Affected:
0 , < V21.01.20
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2025-06-10T19:02:29.811Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-01209.html"
},
{
"url": "https://www.kb.cert.org/vuls/id/282450"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 6.6,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:N/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2025-2884",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-06-13T01:41:10.489446Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125 Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-06-13T01:46:13.802Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC CN 4100",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Field PG M5",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Field PG M6",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V26.01.14",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC BX-32A",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V29.01.09",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC BX-39A",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V29.01.09",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC BX-56A",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V32.01.09",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC BX-59A",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V32.01.09",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC MD-57A",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V30.01.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC PX-32A",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V29.01.09",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC PX-39A",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V29.01.09",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC PX-39A PRO",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V29.01.09",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC RW-528A",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V34.01.02",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC RW-548A",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V34.01.02",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC227E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC277E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC427E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.20",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC477E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.20",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC477E PRO",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.20",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC627E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC647E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC677E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC847E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ITP1000",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS IPC427E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.20",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-08-11T12:22:36.753Z",
"orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
"shortName": "siemens-SADP"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-628843.html"
}
],
"x_adpType": "supplier"
}
],
"cna": {
"affected": [
{
"product": "TPM2.0",
"vendor": "Trusted Computing Group",
"versions": [
{
"lessThan": "1.83",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "TCG TPM2.0 Reference implementation\u0027s CryptHmacSign helper function is vulnerable to Out-of-Bounds read due to the lack of validation the signature scheme with the signature key\u0027s algorithm. See Errata Revision 1.83 and advisory TCGVRT0009 for TCG standard TPM2.0"
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-2884",
"selections": [
{
"name": "Exploitation",
"namespace": "ssvc",
"values": [
"none"
],
"version": "1.0.0"
},
{
"name": "Automatable",
"namespace": "ssvc",
"values": [
"no"
],
"version": "2.0.0"
},
{
"name": "Technical Impact",
"namespace": "ssvc",
"values": [
"partial"
],
"version": "1.0.0"
},
{
"name": "Mission \u0026 Well-being",
"namespace": "ssvc",
"values": [
"medium"
],
"version": "1.0.0"
}
],
"timestamp": "2025-06-13T17:22:30.584Z"
},
"type": "ssvcV1_0_1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "CWE-125 Out-of-bounds Read",
"lang": "en"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-06-13T18:22:21.856Z",
"orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
"shortName": "certcc"
},
"references": [
{
"url": "https://trustedcomputinggroup.org/about/security/"
},
{
"name": "TPM2.0 Errata",
"url": "https://trustedcomputinggroup.org/wp-content/uploads/TPM2.0-Library-Spec-v1.83-Errata_v1_pub.pdf"
},
{
"name": "Vendor Advisory",
"url": "https://trustedcomputinggroup.org/wp-content/uploads/VRT0009-Advisory-FINAL.pdf"
},
{
"name": "Vendor Patch",
"url": "https://github.com/stefanberger/libtpms/commit/04b2d8e9afc0a9b6bffe562a23e58c0de11532d1"
},
{
"name": "Related CVE",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-49133"
}
],
"source": {
"discovery": "INTERNAL"
},
"title": "Out-of-Bounds read vulnerability in TCG TPM2.0 reference implementation",
"x_generator": {
"engine": "VINCE 3.0.20",
"env": "prod",
"origin": "https://cveawg.mitre.org/api/cve/CVE-2025-2884"
}
}
},
"cveMetadata": {
"assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
"assignerShortName": "certcc",
"cveId": "CVE-2025-2884",
"datePublished": "2025-06-10T17:29:19.463Z",
"dateReserved": "2025-03-27T21:01:41.908Z",
"dateUpdated": "2026-08-11T12:22:36.753Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2022-21198 (GCVE-0-2022-21198)
Vulnerability from cvelistv5 – Published: 2022-11-11 15:49 – Updated: 2026-08-11 12:22
VLAI
EPSS
VEX
Summary
Time-of-check time-of-use race condition in the BIOS firmware for some Intel(R) Processors may allow a privileged user to potentially enable escalation of privilege via local access.
Severity
7.9 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-01-29 20:38 UTC
CWE
- escalation of privilege
- CWE-367 - Time-of-check Time-of-use (TOCTOU) Race Condition
Assigner
References
Impacted products
15 products
| Vendor | Product | Version | |
|---|---|---|---|
| n/a | Intel(R) Processors |
Affected:
See references
|
|
| Siemens | SIMATIC Field PG M5 |
Affected:
0 , < V22.01.11
(custom)
|
|
| Siemens | SIMATIC Field PG M6 |
Affected:
0 , < V26.01.11
(custom)
|
|
| Siemens | SIMATIC IPC BX-39A |
Affected:
0 , < V29.01.03
(custom)
|
|
| Siemens | SIMATIC IPC PX-39A |
Affected:
0 , < V29.01.03
(custom)
|
|
| Siemens | SIMATIC IPC PX-39A PRO |
Affected:
0 , < V29.01.03
(custom)
|
|
| Siemens | SIMATIC IPC427E |
Affected:
0 , < V21.01.19
(custom)
|
|
| Siemens | SIMATIC IPC477E |
Affected:
0 , < V21.01.19
(custom)
|
|
| Siemens | SIMATIC IPC477E PRO |
Affected:
0 , < V21.01.19
(custom)
|
|
| Siemens | SIMATIC IPC627E |
Affected:
0 , < V25.02.14
(custom)
|
|
| Siemens | SIMATIC IPC647E |
Affected:
0 , < V25.02.14
(custom)
|
|
| Siemens | SIMATIC IPC677E |
Affected:
0 , < V25.02.14
(custom)
|
|
| Siemens | SIMATIC IPC847E |
Affected:
0 , < V25.02.14
(custom)
|
|
| Siemens | SIMATIC ITP1000 |
Affected:
0 , < *
(custom)
|
|
| Siemens | SIPLUS IPC427E |
Affected:
0 , < V21.01.19
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T02:31:59.787Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00688.html",
"tags": [
"x_transferred"
],
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00688.html"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-21198",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-29T20:38:21.227981Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-367",
"description": "CWE-367 Time-of-check Time-of-use (TOCTOU) Race Condition",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-04T17:58:34.848Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC Field PG M5",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V22.01.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Field PG M6",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V26.01.11",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC BX-39A",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V29.01.03",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC PX-39A",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V29.01.03",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC PX-39A PRO",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V29.01.03",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC427E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.19",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC477E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.19",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC477E PRO",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.19",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC627E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.14",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC647E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.14",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC677E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.14",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC847E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.14",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ITP1000",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS IPC427E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.19",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-08-11T12:22:27.669Z",
"orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
"shortName": "siemens-SADP"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-686975.html"
}
],
"x_adpType": "supplier"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Intel(R) Processors",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "See references"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Time-of-check time-of-use race condition in the BIOS firmware for some Intel(R) Processors may allow a privileged user to potentially enable escalation of privilege via local access."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.9,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:N/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "escalation of privilege",
"lang": "en"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-11-14T17:46:28.257Z",
"orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"shortName": "intel"
},
"references": [
{
"name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00688.html",
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00688.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
"assignerShortName": "intel",
"cveId": "CVE-2022-21198",
"datePublished": "2022-11-11T15:49:10.831Z",
"dateReserved": "2022-02-18T21:23:59.775Z",
"dateUpdated": "2026-08-11T12:22:27.669Z",
"requesterUserId": "524a9a6b-3515-4b97-ab85-1a9a79493852",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2022-24031 (GCVE-0-2022-24031)
Vulnerability from cvelistv5 – Published: 2022-02-03 01:59 – Updated: 2026-08-11 12:22
VLAI
EPSS
VEX
Summary
An issue was discovered in NvmExpressDxe in Insyde InsydeH2O with kernel 5.1 through 5.5. An SMM memory corruption vulnerability allows an attacker to write fixed or predictable data to SMRAM. Exploiting this issue could lead to escalating privileges to SMM.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
6 references
| URL | Tags |
|---|---|
| https://www.insyde.com/security-pledge | x_refsource_MISC |
| https://www.insyde.com/security-pledge/SA-2022015 | x_refsource_MISC |
| https://security.netapp.com/advisory/ntap-2022021… | x_refsource_CONFIRM |
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_CONFIRM |
| https://www.kb.cert.org/vuls/id/796611 | |
| https://cert-portal.siemens.com/productcert/html/… |
Impacted products
18 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | RUGGEDCOM APE1808 - BIOS |
Affected:
0 , < V1.0.202N
(custom)
|
|
| Siemens | SIMATIC Field PG M5 |
Affected:
0 , < V22.01.10
(custom)
|
|
| Siemens | SIMATIC Field PG M6 |
Affected:
0 , < V26.01.13
(custom)
|
|
| Siemens | SIMATIC IPC127E |
Affected:
0 , < V27.01.09
(custom)
|
|
| Siemens | SIMATIC IPC227G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC277G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC277G PRO |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC327G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC377G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC427E |
Affected:
0 , < V21.01.17
(custom)
|
|
| Siemens | SIMATIC IPC477E |
Affected:
0 , < V21.01.17
(custom)
|
|
| Siemens | SIMATIC IPC477E PRO |
Affected:
0 , < V21.01.17
(custom)
|
|
| Siemens | SIMATIC IPC627E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC IPC647E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC IPC677E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC IPC847E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC ITP1000 |
Affected:
0 , < V23.01.10
(custom)
|
|
| Siemens | SIPLUS IPC427E |
Affected:
0 , < V21.01.17
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2025-11-04T19:12:59.895Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.insyde.com/security-pledge"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.insyde.com/security-pledge/SA-2022015"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://security.netapp.com/advisory/ntap-20220216-0009/"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
},
{
"url": "https://www.kb.cert.org/vuls/id/796611"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM APE1808 - BIOS",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.0.202N",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Field PG M5",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V22.01.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Field PG M6",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V26.01.13",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC127E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V27.01.09",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC227G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC277G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC\u00a0IPC277G PRO",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC327G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC377G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC427E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC477E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC477E PRO",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC627E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC647E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC677E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC847E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ITP1000",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V23.01.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS IPC427E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-08-11T12:22:29.973Z",
"orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
"shortName": "siemens-SADP"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-306654.html"
}
],
"x_adpType": "supplier"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered in NvmExpressDxe in Insyde InsydeH2O with kernel 5.1 through 5.5. An SMM memory corruption vulnerability allows an attacker to write fixed or predictable data to SMRAM. Exploiting this issue could lead to escalating privileges to SMM."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-02-22T19:06:47.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.insyde.com/security-pledge"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.insyde.com/security-pledge/SA-2022015"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://security.netapp.com/advisory/ntap-20220216-0009/"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2022-24031",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An issue was discovered in NvmExpressDxe in Insyde InsydeH2O with kernel 5.1 through 5.5. An SMM memory corruption vulnerability allows an attacker to write fixed or predictable data to SMRAM. Exploiting this issue could lead to escalating privileges to SMM."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.insyde.com/security-pledge",
"refsource": "MISC",
"url": "https://www.insyde.com/security-pledge"
},
{
"name": "https://www.insyde.com/security-pledge/SA-2022015",
"refsource": "MISC",
"url": "https://www.insyde.com/security-pledge/SA-2022015"
},
{
"name": "https://security.netapp.com/advisory/ntap-20220216-0009/",
"refsource": "CONFIRM",
"url": "https://security.netapp.com/advisory/ntap-20220216-0009/"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2022-24031",
"datePublished": "2022-02-03T01:59:49.000Z",
"dateReserved": "2022-01-26T00:00:00.000Z",
"dateUpdated": "2026-08-11T12:22:29.973Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2021-33625 (GCVE-0-2021-33625)
Vulnerability from cvelistv5 – Published: 2022-02-03 01:55 – Updated: 2026-08-11 12:22
VLAI
EPSS
VEX
Summary
An issue was discovered in Kernel 5.x in Insyde InsydeH2O, affecting HddPassword. Software SMI services that use the Communicate() function of the EFI_SMM_COMMUNICATION_PROTOCOL do not check whether the address of the buffer is valid, which allows use of SMRAM, MMIO, or OS kernel addresses.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
6 references
| URL | Tags |
|---|---|
| https://www.insyde.com/security-pledge | x_refsource_MISC |
| https://www.insyde.com/security-pledge/SA-2022014 | x_refsource_MISC |
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_CONFIRM |
| https://security.netapp.com/advisory/ntap-2022022… | x_refsource_CONFIRM |
| https://www.kb.cert.org/vuls/id/796611 | |
| https://cert-portal.siemens.com/productcert/html/… |
Impacted products
18 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | RUGGEDCOM APE1808 - BIOS |
Affected:
0 , < V1.0.202N
(custom)
|
|
| Siemens | SIMATIC Field PG M5 |
Affected:
0 , < V22.01.10
(custom)
|
|
| Siemens | SIMATIC Field PG M6 |
Affected:
0 , < V26.01.13
(custom)
|
|
| Siemens | SIMATIC IPC127E |
Affected:
0 , < V27.01.09
(custom)
|
|
| Siemens | SIMATIC IPC227G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC277G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC277G PRO |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC327G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC377G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC427E |
Affected:
0 , < V21.01.17
(custom)
|
|
| Siemens | SIMATIC IPC477E |
Affected:
0 , < V21.01.17
(custom)
|
|
| Siemens | SIMATIC IPC477E PRO |
Affected:
0 , < V21.01.17
(custom)
|
|
| Siemens | SIMATIC IPC627E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC IPC647E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC IPC677E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC IPC847E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC ITP1000 |
Affected:
0 , < V23.01.10
(custom)
|
|
| Siemens | SIPLUS IPC427E |
Affected:
0 , < V21.01.17
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2025-11-04T19:12:29.871Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.insyde.com/security-pledge"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.insyde.com/security-pledge/SA-2022014"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://security.netapp.com/advisory/ntap-20220222-0004/"
},
{
"url": "https://www.kb.cert.org/vuls/id/796611"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM APE1808 - BIOS",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.0.202N",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Field PG M5",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V22.01.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Field PG M6",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V26.01.13",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC127E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V27.01.09",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC227G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC277G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC\u00a0IPC277G PRO",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC327G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC377G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC427E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC477E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC477E PRO",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC627E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC647E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC677E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC847E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ITP1000",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V23.01.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS IPC427E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-08-11T12:22:04.521Z",
"orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
"shortName": "siemens-SADP"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-306654.html"
}
],
"x_adpType": "supplier"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered in Kernel 5.x in Insyde InsydeH2O, affecting HddPassword. Software SMI services that use the Communicate() function of the EFI_SMM_COMMUNICATION_PROTOCOL do not check whether the address of the buffer is valid, which allows use of SMRAM, MMIO, or OS kernel addresses."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-02-23T15:06:25.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.insyde.com/security-pledge"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.insyde.com/security-pledge/SA-2022014"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://security.netapp.com/advisory/ntap-20220222-0004/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2021-33625",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An issue was discovered in Kernel 5.x in Insyde InsydeH2O, affecting HddPassword. Software SMI services that use the Communicate() function of the EFI_SMM_COMMUNICATION_PROTOCOL do not check whether the address of the buffer is valid, which allows use of SMRAM, MMIO, or OS kernel addresses."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.insyde.com/security-pledge",
"refsource": "MISC",
"url": "https://www.insyde.com/security-pledge"
},
{
"name": "https://www.insyde.com/security-pledge/SA-2022014",
"refsource": "MISC",
"url": "https://www.insyde.com/security-pledge/SA-2022014"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
},
{
"name": "https://security.netapp.com/advisory/ntap-20220222-0004/",
"refsource": "CONFIRM",
"url": "https://security.netapp.com/advisory/ntap-20220222-0004/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2021-33625",
"datePublished": "2022-02-03T01:55:10.000Z",
"dateReserved": "2021-05-28T00:00:00.000Z",
"dateUpdated": "2026-08-11T12:22:04.521Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2021-43323 (GCVE-0-2021-43323)
Vulnerability from cvelistv5 – Published: 2022-02-03 01:50 – Updated: 2026-08-11 12:22
VLAI
EPSS
VEX
Summary
An issue was discovered in UsbCoreDxe in Insyde InsydeH2O with kernel 5.5 before 05.51.45, 5.4 before 05.43.45, 5.3 before 05.35.45, 5.2 before 05.26.45, 5.1 before 05.16.45, and 5.0 before 05.08.45. An SMM callout vulnerability allows an attacker to hijack execution flow of code running in System Management Mode. Exploiting this issue could lead to escalating privileges to SMM.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
5 references
| URL | Tags |
|---|---|
| https://www.insyde.com/security-pledge | x_refsource_MISC |
| https://security.netapp.com/advisory/ntap-2022021… | x_refsource_CONFIRM |
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_CONFIRM |
| https://www.kb.cert.org/vuls/id/796611 | |
| https://cert-portal.siemens.com/productcert/html/… |
Impacted products
18 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | RUGGEDCOM APE1808 - BIOS |
Affected:
0 , < V1.0.202N
(custom)
|
|
| Siemens | SIMATIC Field PG M5 |
Affected:
0 , < V22.01.10
(custom)
|
|
| Siemens | SIMATIC Field PG M6 |
Affected:
0 , < V26.01.13
(custom)
|
|
| Siemens | SIMATIC IPC127E |
Affected:
0 , < V27.01.09
(custom)
|
|
| Siemens | SIMATIC IPC227G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC277G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC277G PRO |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC327G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC377G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC427E |
Affected:
0 , < V21.01.17
(custom)
|
|
| Siemens | SIMATIC IPC477E |
Affected:
0 , < V21.01.17
(custom)
|
|
| Siemens | SIMATIC IPC477E PRO |
Affected:
0 , < V21.01.17
(custom)
|
|
| Siemens | SIMATIC IPC627E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC IPC647E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC IPC677E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC IPC847E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC ITP1000 |
Affected:
0 , < V23.01.10
(custom)
|
|
| Siemens | SIPLUS IPC427E |
Affected:
0 , < V21.01.17
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2025-11-04T19:12:44.192Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.insyde.com/security-pledge"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://security.netapp.com/advisory/ntap-20220217-0013/"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
},
{
"url": "https://www.kb.cert.org/vuls/id/796611"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM APE1808 - BIOS",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.0.202N",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Field PG M5",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V22.01.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Field PG M6",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V26.01.13",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC127E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V27.01.09",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC227G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC277G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC\u00a0IPC277G PRO",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC327G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC377G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC427E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC477E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC477E PRO",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC627E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC647E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC677E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC847E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ITP1000",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V23.01.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS IPC427E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-08-11T12:22:19.420Z",
"orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
"shortName": "siemens-SADP"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-306654.html"
}
],
"x_adpType": "supplier"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered in UsbCoreDxe in Insyde InsydeH2O with kernel 5.5 before 05.51.45, 5.4 before 05.43.45, 5.3 before 05.35.45, 5.2 before 05.26.45, 5.1 before 05.16.45, and 5.0 before 05.08.45. An SMM callout vulnerability allows an attacker to hijack execution flow of code running in System Management Mode. Exploiting this issue could lead to escalating privileges to SMM."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-02-22T19:06:29.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.insyde.com/security-pledge"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://security.netapp.com/advisory/ntap-20220217-0013/"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2021-43323",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An issue was discovered in UsbCoreDxe in Insyde InsydeH2O with kernel 5.5 before 05.51.45, 5.4 before 05.43.45, 5.3 before 05.35.45, 5.2 before 05.26.45, 5.1 before 05.16.45, and 5.0 before 05.08.45. An SMM callout vulnerability allows an attacker to hijack execution flow of code running in System Management Mode. Exploiting this issue could lead to escalating privileges to SMM."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.insyde.com/security-pledge",
"refsource": "MISC",
"url": "https://www.insyde.com/security-pledge"
},
{
"name": "https://security.netapp.com/advisory/ntap-20220217-0013/",
"refsource": "CONFIRM",
"url": "https://security.netapp.com/advisory/ntap-20220217-0013/"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2021-43323",
"datePublished": "2022-02-03T01:50:01.000Z",
"dateReserved": "2021-11-03T00:00:00.000Z",
"dateUpdated": "2026-08-11T12:22:19.420Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2021-42113 (GCVE-0-2021-42113)
Vulnerability from cvelistv5 – Published: 2022-02-03 01:46 – Updated: 2026-08-11 12:22
VLAI
EPSS
VEX
Summary
An issue was discovered in StorageSecurityCommandDxe in Insyde InsydeH2O with Kernel 5.1 before 05.14.28, Kernel 5.2 before 05.24.28, and Kernel 5.3 before 05.32.25. An SMM callout vulnerability allows an attacker to hijack execution flow of code running in System Management Mode. Exploiting this issue could lead to escalating privileges to SMM.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
6 references
| URL | Tags |
|---|---|
| https://www.insyde.com/security-pledge | x_refsource_MISC |
| https://www.insyde.com/security-pledge/SA-2022008 | x_refsource_MISC |
| https://security.netapp.com/advisory/ntap-2022021… | x_refsource_CONFIRM |
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_CONFIRM |
| https://www.kb.cert.org/vuls/id/796611 | |
| https://cert-portal.siemens.com/productcert/html/… |
Impacted products
18 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | RUGGEDCOM APE1808 - BIOS |
Affected:
0 , < V1.0.202N
(custom)
|
|
| Siemens | SIMATIC Field PG M5 |
Affected:
0 , < V22.01.10
(custom)
|
|
| Siemens | SIMATIC Field PG M6 |
Affected:
0 , < V26.01.13
(custom)
|
|
| Siemens | SIMATIC IPC127E |
Affected:
0 , < V27.01.09
(custom)
|
|
| Siemens | SIMATIC IPC227G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC277G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC277G PRO |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC327G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC377G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC427E |
Affected:
0 , < V21.01.17
(custom)
|
|
| Siemens | SIMATIC IPC477E |
Affected:
0 , < V21.01.17
(custom)
|
|
| Siemens | SIMATIC IPC477E PRO |
Affected:
0 , < V21.01.17
(custom)
|
|
| Siemens | SIMATIC IPC627E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC IPC647E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC IPC677E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC IPC847E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC ITP1000 |
Affected:
0 , < V23.01.10
(custom)
|
|
| Siemens | SIPLUS IPC427E |
Affected:
0 , < V21.01.17
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2025-11-04T19:12:42.015Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.insyde.com/security-pledge"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.insyde.com/security-pledge/SA-2022008"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://security.netapp.com/advisory/ntap-20220216-0012/"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
},
{
"url": "https://www.kb.cert.org/vuls/id/796611"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM APE1808 - BIOS",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.0.202N",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Field PG M5",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V22.01.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Field PG M6",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V26.01.13",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC127E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V27.01.09",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC227G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC277G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC\u00a0IPC277G PRO",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC327G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC377G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC427E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC477E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC477E PRO",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC627E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC647E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC677E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC847E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ITP1000",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V23.01.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS IPC427E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-08-11T12:22:17.067Z",
"orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
"shortName": "siemens-SADP"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-306654.html"
}
],
"x_adpType": "supplier"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered in StorageSecurityCommandDxe in Insyde InsydeH2O with Kernel 5.1 before 05.14.28, Kernel 5.2 before 05.24.28, and Kernel 5.3 before 05.32.25. An SMM callout vulnerability allows an attacker to hijack execution flow of code running in System Management Mode. Exploiting this issue could lead to escalating privileges to SMM."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-02-22T19:06:49.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.insyde.com/security-pledge"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.insyde.com/security-pledge/SA-2022008"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://security.netapp.com/advisory/ntap-20220216-0012/"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2021-42113",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An issue was discovered in StorageSecurityCommandDxe in Insyde InsydeH2O with Kernel 5.1 before 05.14.28, Kernel 5.2 before 05.24.28, and Kernel 5.3 before 05.32.25. An SMM callout vulnerability allows an attacker to hijack execution flow of code running in System Management Mode. Exploiting this issue could lead to escalating privileges to SMM."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.insyde.com/security-pledge",
"refsource": "MISC",
"url": "https://www.insyde.com/security-pledge"
},
{
"name": "https://www.insyde.com/security-pledge/SA-2022008",
"refsource": "MISC",
"url": "https://www.insyde.com/security-pledge/SA-2022008"
},
{
"name": "https://security.netapp.com/advisory/ntap-20220216-0012/",
"refsource": "CONFIRM",
"url": "https://security.netapp.com/advisory/ntap-20220216-0012/"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2021-42113",
"datePublished": "2022-02-03T01:46:08.000Z",
"dateReserved": "2021-10-08T00:00:00.000Z",
"dateUpdated": "2026-08-11T12:22:17.067Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2021-41838 (GCVE-0-2021-41838)
Vulnerability from cvelistv5 – Published: 2022-02-03 01:43 – Updated: 2026-08-11 12:22
VLAI
EPSS
VEX
Summary
An issue was discovered in SdHostDriver in the kernel 5.0 through 5.5 in Insyde InsydeH2O. There is an SMM callout that allows an attacker to access the System Management Mode and execute arbitrary code. This occurs because of a Numeric Range Comparison Without a Minimum Check.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
6 references
| URL | Tags |
|---|---|
| https://www.insyde.com/security-pledge | x_refsource_MISC |
| https://www.insyde.com/security-pledge/SA-2022023 | x_refsource_MISC |
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_CONFIRM |
| https://security.netapp.com/advisory/ntap-2022022… | x_refsource_CONFIRM |
| https://www.kb.cert.org/vuls/id/796611 | |
| https://cert-portal.siemens.com/productcert/html/… |
Impacted products
18 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | RUGGEDCOM APE1808 - BIOS |
Affected:
0 , < V1.0.202N
(custom)
|
|
| Siemens | SIMATIC Field PG M5 |
Affected:
0 , < V22.01.10
(custom)
|
|
| Siemens | SIMATIC Field PG M6 |
Affected:
0 , < V26.01.13
(custom)
|
|
| Siemens | SIMATIC IPC127E |
Affected:
0 , < V27.01.09
(custom)
|
|
| Siemens | SIMATIC IPC227G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC277G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC277G PRO |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC327G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC377G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC427E |
Affected:
0 , < V21.01.17
(custom)
|
|
| Siemens | SIMATIC IPC477E |
Affected:
0 , < V21.01.17
(custom)
|
|
| Siemens | SIMATIC IPC477E PRO |
Affected:
0 , < V21.01.17
(custom)
|
|
| Siemens | SIMATIC IPC627E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC IPC647E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC IPC677E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC IPC847E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC ITP1000 |
Affected:
0 , < V23.01.10
(custom)
|
|
| Siemens | SIPLUS IPC427E |
Affected:
0 , < V21.01.17
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2025-11-04T19:12:35.317Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.insyde.com/security-pledge"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.insyde.com/security-pledge/SA-2022023"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://security.netapp.com/advisory/ntap-20220222-0001/"
},
{
"url": "https://www.kb.cert.org/vuls/id/796611"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM APE1808 - BIOS",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.0.202N",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Field PG M5",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V22.01.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Field PG M6",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V26.01.13",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC127E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V27.01.09",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC227G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC277G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC\u00a0IPC277G PRO",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC327G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC377G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC427E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC477E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC477E PRO",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC627E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC647E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC677E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC847E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ITP1000",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V23.01.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS IPC427E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-08-11T12:22:09.947Z",
"orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
"shortName": "siemens-SADP"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-306654.html"
}
],
"x_adpType": "supplier"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered in SdHostDriver in the kernel 5.0 through 5.5 in Insyde InsydeH2O. There is an SMM callout that allows an attacker to access the System Management Mode and execute arbitrary code. This occurs because of a Numeric Range Comparison Without a Minimum Check."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-02-23T15:06:23.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.insyde.com/security-pledge"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.insyde.com/security-pledge/SA-2022023"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://security.netapp.com/advisory/ntap-20220222-0001/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2021-41838",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An issue was discovered in SdHostDriver in the kernel 5.0 through 5.5 in Insyde InsydeH2O. There is an SMM callout that allows an attacker to access the System Management Mode and execute arbitrary code. This occurs because of a Numeric Range Comparison Without a Minimum Check."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.insyde.com/security-pledge",
"refsource": "MISC",
"url": "https://www.insyde.com/security-pledge"
},
{
"name": "https://www.insyde.com/security-pledge/SA-2022023",
"refsource": "MISC",
"url": "https://www.insyde.com/security-pledge/SA-2022023"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
},
{
"name": "https://security.netapp.com/advisory/ntap-20220222-0001/",
"refsource": "CONFIRM",
"url": "https://security.netapp.com/advisory/ntap-20220222-0001/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2021-41838",
"datePublished": "2022-02-03T01:43:30.000Z",
"dateReserved": "2021-10-01T00:00:00.000Z",
"dateUpdated": "2026-08-11T12:22:09.947Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2021-42554 (GCVE-0-2021-42554)
Vulnerability from cvelistv5 – Published: 2022-02-03 01:40 – Updated: 2026-08-11 12:22
VLAI
EPSS
VEX
Summary
An issue was discovered in Insyde InsydeH2O with Kernel 5.0 before 05.08.42, Kernel 5.1 before 05.16.42, Kernel 5.2 before 05.26.42, Kernel 5.3 before 05.35.42, Kernel 5.4 before 05.42.51, and Kernel 5.5 before 05.50.51. An SMM memory corruption vulnerability in FvbServicesRuntimeDxe allows a possible attacker to write fixed or predictable data to SMRAM. Exploiting this issue could lead to escalating privileges to SMM.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
6 references
| URL | Tags |
|---|---|
| https://www.insyde.com/security-pledge | x_refsource_MISC |
| https://www.insyde.com/security-pledge/SA-2022012 | x_refsource_MISC |
| https://security.netapp.com/advisory/ntap-2022021… | x_refsource_CONFIRM |
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_CONFIRM |
| https://www.kb.cert.org/vuls/id/796611 | |
| https://cert-portal.siemens.com/productcert/html/… |
Impacted products
18 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | RUGGEDCOM APE1808 - BIOS |
Affected:
0 , < V1.0.202N
(custom)
|
|
| Siemens | SIMATIC Field PG M5 |
Affected:
0 , < V22.01.10
(custom)
|
|
| Siemens | SIMATIC Field PG M6 |
Affected:
0 , < V26.01.13
(custom)
|
|
| Siemens | SIMATIC IPC127E |
Affected:
0 , < V27.01.09
(custom)
|
|
| Siemens | SIMATIC IPC227G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC277G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC277G PRO |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC327G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC377G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC427E |
Affected:
0 , < V21.01.17
(custom)
|
|
| Siemens | SIMATIC IPC477E |
Affected:
0 , < V21.01.17
(custom)
|
|
| Siemens | SIMATIC IPC477E PRO |
Affected:
0 , < V21.01.17
(custom)
|
|
| Siemens | SIMATIC IPC627E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC IPC647E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC IPC677E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC IPC847E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC ITP1000 |
Affected:
0 , < V23.01.10
(custom)
|
|
| Siemens | SIPLUS IPC427E |
Affected:
0 , < V21.01.17
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2025-11-04T19:12:43.116Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.insyde.com/security-pledge"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.insyde.com/security-pledge/SA-2022012"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://security.netapp.com/advisory/ntap-20220216-0007/"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
},
{
"url": "https://www.kb.cert.org/vuls/id/796611"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM APE1808 - BIOS",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.0.202N",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Field PG M5",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V22.01.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Field PG M6",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V26.01.13",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC127E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V27.01.09",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC227G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC277G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC\u00a0IPC277G PRO",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC327G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC377G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC427E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC477E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC477E PRO",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC627E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC647E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC677E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC847E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ITP1000",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V23.01.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS IPC427E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-08-11T12:22:18.229Z",
"orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
"shortName": "siemens-SADP"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-306654.html"
}
],
"x_adpType": "supplier"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered in Insyde InsydeH2O with Kernel 5.0 before 05.08.42, Kernel 5.1 before 05.16.42, Kernel 5.2 before 05.26.42, Kernel 5.3 before 05.35.42, Kernel 5.4 before 05.42.51, and Kernel 5.5 before 05.50.51. An SMM memory corruption vulnerability in FvbServicesRuntimeDxe allows a possible attacker to write fixed or predictable data to SMRAM. Exploiting this issue could lead to escalating privileges to SMM."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-02-22T19:06:40.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.insyde.com/security-pledge"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.insyde.com/security-pledge/SA-2022012"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://security.netapp.com/advisory/ntap-20220216-0007/"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2021-42554",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An issue was discovered in Insyde InsydeH2O with Kernel 5.0 before 05.08.42, Kernel 5.1 before 05.16.42, Kernel 5.2 before 05.26.42, Kernel 5.3 before 05.35.42, Kernel 5.4 before 05.42.51, and Kernel 5.5 before 05.50.51. An SMM memory corruption vulnerability in FvbServicesRuntimeDxe allows a possible attacker to write fixed or predictable data to SMRAM. Exploiting this issue could lead to escalating privileges to SMM."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.insyde.com/security-pledge",
"refsource": "MISC",
"url": "https://www.insyde.com/security-pledge"
},
{
"name": "https://www.insyde.com/security-pledge/SA-2022012",
"refsource": "MISC",
"url": "https://www.insyde.com/security-pledge/SA-2022012"
},
{
"name": "https://security.netapp.com/advisory/ntap-20220216-0007/",
"refsource": "CONFIRM",
"url": "https://security.netapp.com/advisory/ntap-20220216-0007/"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2021-42554",
"datePublished": "2022-02-03T01:40:56.000Z",
"dateReserved": "2021-10-18T00:00:00.000Z",
"dateUpdated": "2026-08-11T12:22:18.229Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2021-41839 (GCVE-0-2021-41839)
Vulnerability from cvelistv5 – Published: 2022-02-03 01:37 – Updated: 2026-08-11 12:22
VLAI
EPSS
VEX
Summary
An issue was discovered in NvmExpressDxe in the kernel 5.0 through 5.5 in Insyde InsydeH2O. Because of an Untrusted Pointer Dereference that causes SMM memory corruption, an attacker may be able to write fixed or predictable data to SMRAM. Exploiting this issue could lead to escalating privileges to SMM.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
6 references
| URL | Tags |
|---|---|
| https://www.insyde.com/security-pledge | x_refsource_MISC |
| https://www.insyde.com/security-pledge/SA-2022020 | x_refsource_MISC |
| https://security.netapp.com/advisory/ntap-2022021… | x_refsource_CONFIRM |
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_CONFIRM |
| https://www.kb.cert.org/vuls/id/796611 | |
| https://cert-portal.siemens.com/productcert/html/… |
Impacted products
18 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | RUGGEDCOM APE1808 - BIOS |
Affected:
0 , < V1.0.202N
(custom)
|
|
| Siemens | SIMATIC Field PG M5 |
Affected:
0 , < V22.01.10
(custom)
|
|
| Siemens | SIMATIC Field PG M6 |
Affected:
0 , < V26.01.13
(custom)
|
|
| Siemens | SIMATIC IPC127E |
Affected:
0 , < V27.01.09
(custom)
|
|
| Siemens | SIMATIC IPC227G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC277G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC277G PRO |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC327G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC377G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC427E |
Affected:
0 , < V21.01.17
(custom)
|
|
| Siemens | SIMATIC IPC477E |
Affected:
0 , < V21.01.17
(custom)
|
|
| Siemens | SIMATIC IPC477E PRO |
Affected:
0 , < V21.01.17
(custom)
|
|
| Siemens | SIMATIC IPC627E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC IPC647E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC IPC677E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC IPC847E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC ITP1000 |
Affected:
0 , < V23.01.10
(custom)
|
|
| Siemens | SIPLUS IPC427E |
Affected:
0 , < V21.01.17
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2025-11-04T19:12:36.407Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.insyde.com/security-pledge"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.insyde.com/security-pledge/SA-2022020"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://security.netapp.com/advisory/ntap-20220217-0016/"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
},
{
"url": "https://www.kb.cert.org/vuls/id/796611"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM APE1808 - BIOS",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.0.202N",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Field PG M5",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V22.01.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Field PG M6",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V26.01.13",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC127E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V27.01.09",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC227G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC277G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC\u00a0IPC277G PRO",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC327G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC377G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC427E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC477E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC477E PRO",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC627E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC647E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC677E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC847E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ITP1000",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V23.01.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS IPC427E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-08-11T12:22:11.112Z",
"orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
"shortName": "siemens-SADP"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-306654.html"
}
],
"x_adpType": "supplier"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered in NvmExpressDxe in the kernel 5.0 through 5.5 in Insyde InsydeH2O. Because of an Untrusted Pointer Dereference that causes SMM memory corruption, an attacker may be able to write fixed or predictable data to SMRAM. Exploiting this issue could lead to escalating privileges to SMM."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-02-22T19:06:25.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.insyde.com/security-pledge"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.insyde.com/security-pledge/SA-2022020"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://security.netapp.com/advisory/ntap-20220217-0016/"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2021-41839",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An issue was discovered in NvmExpressDxe in the kernel 5.0 through 5.5 in Insyde InsydeH2O. Because of an Untrusted Pointer Dereference that causes SMM memory corruption, an attacker may be able to write fixed or predictable data to SMRAM. Exploiting this issue could lead to escalating privileges to SMM."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.insyde.com/security-pledge",
"refsource": "MISC",
"url": "https://www.insyde.com/security-pledge"
},
{
"name": "https://www.insyde.com/security-pledge/SA-2022020",
"refsource": "MISC",
"url": "https://www.insyde.com/security-pledge/SA-2022020"
},
{
"name": "https://security.netapp.com/advisory/ntap-20220217-0016/",
"refsource": "CONFIRM",
"url": "https://security.netapp.com/advisory/ntap-20220217-0016/"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2021-41839",
"datePublished": "2022-02-03T01:37:10.000Z",
"dateReserved": "2021-10-01T00:00:00.000Z",
"dateUpdated": "2026-08-11T12:22:11.112Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2021-33627 (GCVE-0-2021-33627)
Vulnerability from cvelistv5 – Published: 2022-02-03 01:30 – Updated: 2026-08-11 12:22
VLAI
EPSS
VEX
Summary
An issue was discovered in Insyde InsydeH2O Kernel 5.0 before 05.09.11, 5.1 before 05.17.11, 5.2 before 05.27.11, 5.3 before 05.36.11, 5.4 before 05.44.11, and 5.5 before 05.52.11 affecting FwBlockServiceSmm. Software SMI services that use the Communicate() function of the EFI_SMM_COMMUNICATION_PROTOCOL do not check whether the address of the buffer is valid, which allows use of SMRAM, MMIO, or OS kernel addresses.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
6 references
Impacted products
18 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | RUGGEDCOM APE1808 - BIOS |
Affected:
0 , < V1.0.202N
(custom)
|
|
| Siemens | SIMATIC Field PG M5 |
Affected:
0 , < V22.01.10
(custom)
|
|
| Siemens | SIMATIC Field PG M6 |
Affected:
0 , < V26.01.13
(custom)
|
|
| Siemens | SIMATIC IPC127E |
Affected:
0 , < V27.01.09
(custom)
|
|
| Siemens | SIMATIC IPC227G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC277G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC277G PRO |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC327G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC377G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC427E |
Affected:
0 , < V21.01.17
(custom)
|
|
| Siemens | SIMATIC IPC477E |
Affected:
0 , < V21.01.17
(custom)
|
|
| Siemens | SIMATIC IPC477E PRO |
Affected:
0 , < V21.01.17
(custom)
|
|
| Siemens | SIMATIC IPC627E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC IPC647E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC IPC677E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC IPC847E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC ITP1000 |
Affected:
0 , < V23.01.10
(custom)
|
|
| Siemens | SIPLUS IPC427E |
Affected:
0 , < V21.01.17
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2025-11-04T19:12:32.043Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.insyde.com/security-pledge"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.insyde.com/security-pledge/SA-2022022"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://security.netapp.com/advisory/ntap-20220222-0002/"
},
{
"url": "https://www.kb.cert.org/vuls/id/796611"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM APE1808 - BIOS",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.0.202N",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Field PG M5",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V22.01.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Field PG M6",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V26.01.13",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC127E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V27.01.09",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC227G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC277G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC\u00a0IPC277G PRO",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC327G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC377G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC427E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC477E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC477E PRO",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC627E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC647E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC677E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC847E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ITP1000",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V23.01.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS IPC427E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-08-11T12:22:07.040Z",
"orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
"shortName": "siemens-SADP"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-306654.html"
}
],
"x_adpType": "supplier"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered in Insyde InsydeH2O Kernel 5.0 before 05.09.11, 5.1 before 05.17.11, 5.2 before 05.27.11, 5.3 before 05.36.11, 5.4 before 05.44.11, and 5.5 before 05.52.11 affecting FwBlockServiceSmm. Software SMI services that use the Communicate() function of the EFI_SMM_COMMUNICATION_PROTOCOL do not check whether the address of the buffer is valid, which allows use of SMRAM, MMIO, or OS kernel addresses."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-07-22T16:50:10.835Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://www.insyde.com/security-pledge"
},
{
"url": "https://www.insyde.com/security-pledge/SA-2022022"
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
},
{
"url": "https://security.netapp.com/advisory/ntap-20220222-0002/"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2021-33627",
"datePublished": "2022-02-03T01:30:36.000Z",
"dateReserved": "2021-05-28T00:00:00.000Z",
"dateUpdated": "2026-08-11T12:22:07.040Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2021-42060 (GCVE-0-2021-42060)
Vulnerability from cvelistv5 – Published: 2022-02-03 01:27 – Updated: 2026-08-11 12:22
VLAI
EPSS
VEX
Summary
An issue was discovered in Insyde InsydeH2O Kernel 5.0 through 05.08.41, Kernel 5.1 through 05.16.41, Kernel 5.2 before 05.23.22, and Kernel 5.3 before 05.32.22. An Int15ServiceSmm SMM callout vulnerability allows an attacker to hijack execution flow of code running in System Management Mode. Exploiting this issue could lead to escalating privileges to SMM.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
6 references
| URL | Tags |
|---|---|
| https://www.insyde.com/security-pledge | x_refsource_MISC |
| https://www.insyde.com/security-pledge/SA-2022007 | x_refsource_MISC |
| https://security.netapp.com/advisory/ntap-2022021… | x_refsource_CONFIRM |
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_CONFIRM |
| https://www.kb.cert.org/vuls/id/796611 | |
| https://cert-portal.siemens.com/productcert/html/… |
Impacted products
18 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | RUGGEDCOM APE1808 - BIOS |
Affected:
0 , < V1.0.202N
(custom)
|
|
| Siemens | SIMATIC Field PG M5 |
Affected:
0 , < V22.01.10
(custom)
|
|
| Siemens | SIMATIC Field PG M6 |
Affected:
0 , < V26.01.13
(custom)
|
|
| Siemens | SIMATIC IPC127E |
Affected:
0 , < V27.01.09
(custom)
|
|
| Siemens | SIMATIC IPC227G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC277G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC277G PRO |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC327G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC377G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC427E |
Affected:
0 , < V21.01.17
(custom)
|
|
| Siemens | SIMATIC IPC477E |
Affected:
0 , < V21.01.17
(custom)
|
|
| Siemens | SIMATIC IPC477E PRO |
Affected:
0 , < V21.01.17
(custom)
|
|
| Siemens | SIMATIC IPC627E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC IPC647E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC IPC677E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC IPC847E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC ITP1000 |
Affected:
0 , < V23.01.10
(custom)
|
|
| Siemens | SIPLUS IPC427E |
Affected:
0 , < V21.01.17
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2025-11-04T19:12:40.921Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.insyde.com/security-pledge"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.insyde.com/security-pledge/SA-2022007"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://security.netapp.com/advisory/ntap-20220217-0015/"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
},
{
"url": "https://www.kb.cert.org/vuls/id/796611"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM APE1808 - BIOS",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.0.202N",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Field PG M5",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V22.01.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Field PG M6",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V26.01.13",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC127E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V27.01.09",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC227G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC277G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC\u00a0IPC277G PRO",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC327G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC377G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC427E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC477E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC477E PRO",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC627E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC647E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC677E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC847E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ITP1000",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V23.01.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS IPC427E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-08-11T12:22:15.909Z",
"orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
"shortName": "siemens-SADP"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-306654.html"
}
],
"x_adpType": "supplier"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered in Insyde InsydeH2O Kernel 5.0 through 05.08.41, Kernel 5.1 through 05.16.41, Kernel 5.2 before 05.23.22, and Kernel 5.3 before 05.32.22. An Int15ServiceSmm SMM callout vulnerability allows an attacker to hijack execution flow of code running in System Management Mode. Exploiting this issue could lead to escalating privileges to SMM."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-02-22T19:06:42.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.insyde.com/security-pledge"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.insyde.com/security-pledge/SA-2022007"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://security.netapp.com/advisory/ntap-20220217-0015/"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2021-42060",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An issue was discovered in Insyde InsydeH2O Kernel 5.0 through 05.08.41, Kernel 5.1 through 05.16.41, Kernel 5.2 before 05.23.22, and Kernel 5.3 before 05.32.22. An Int15ServiceSmm SMM callout vulnerability allows an attacker to hijack execution flow of code running in System Management Mode. Exploiting this issue could lead to escalating privileges to SMM."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.insyde.com/security-pledge",
"refsource": "MISC",
"url": "https://www.insyde.com/security-pledge"
},
{
"name": "https://www.insyde.com/security-pledge/SA-2022007",
"refsource": "MISC",
"url": "https://www.insyde.com/security-pledge/SA-2022007"
},
{
"name": "https://security.netapp.com/advisory/ntap-20220217-0015/",
"refsource": "CONFIRM",
"url": "https://security.netapp.com/advisory/ntap-20220217-0015/"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2021-42060",
"datePublished": "2022-02-03T01:27:34.000Z",
"dateReserved": "2021-10-07T00:00:00.000Z",
"dateUpdated": "2026-08-11T12:22:15.909Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2021-41837 (GCVE-0-2021-41837)
Vulnerability from cvelistv5 – Published: 2022-02-03 01:23 – Updated: 2026-08-11 12:22
VLAI
EPSS
VEX
Summary
An issue was discovered in AhciBusDxe in the kernel 5.0 through 5.5 in Insyde InsydeH2O. Because of an Untrusted Pointer Dereference that causes SMM memory corruption, an attacker may be able to write fixed or predictable data to SMRAM. Exploiting this issue could lead to escalating privileges to SMM.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
6 references
| URL | Tags |
|---|---|
| https://www.insyde.com/security-pledge | x_refsource_MISC |
| https://www.insyde.com/security-pledge/SA-2022024 | x_refsource_MISC |
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_CONFIRM |
| https://security.netapp.com/advisory/ntap-2022022… | x_refsource_CONFIRM |
| https://www.kb.cert.org/vuls/id/796611 | |
| https://cert-portal.siemens.com/productcert/html/… |
Impacted products
18 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | RUGGEDCOM APE1808 - BIOS |
Affected:
0 , < V1.0.202N
(custom)
|
|
| Siemens | SIMATIC Field PG M5 |
Affected:
0 , < V22.01.10
(custom)
|
|
| Siemens | SIMATIC Field PG M6 |
Affected:
0 , < V26.01.13
(custom)
|
|
| Siemens | SIMATIC IPC127E |
Affected:
0 , < V27.01.09
(custom)
|
|
| Siemens | SIMATIC IPC227G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC277G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC277G PRO |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC327G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC377G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC427E |
Affected:
0 , < V21.01.17
(custom)
|
|
| Siemens | SIMATIC IPC477E |
Affected:
0 , < V21.01.17
(custom)
|
|
| Siemens | SIMATIC IPC477E PRO |
Affected:
0 , < V21.01.17
(custom)
|
|
| Siemens | SIMATIC IPC627E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC IPC647E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC IPC677E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC IPC847E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC ITP1000 |
Affected:
0 , < V23.01.10
(custom)
|
|
| Siemens | SIPLUS IPC427E |
Affected:
0 , < V21.01.17
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2025-11-04T19:12:34.238Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.insyde.com/security-pledge"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.insyde.com/security-pledge/SA-2022024"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://security.netapp.com/advisory/ntap-20220222-0003/"
},
{
"url": "https://www.kb.cert.org/vuls/id/796611"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"defaultStatus": "unknown",
"product": "RUGGEDCOM APE1808 - BIOS",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.0.202N",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Field PG M5",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V22.01.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Field PG M6",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V26.01.13",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC127E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V27.01.09",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC227G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC277G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC\u00a0IPC277G PRO",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC327G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC377G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC427E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC477E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC477E PRO",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC627E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC647E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC677E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC847E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ITP1000",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V23.01.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS IPC427E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-08-11T12:22:08.782Z",
"orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
"shortName": "siemens-SADP"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-306654.html"
}
],
"x_adpType": "supplier"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered in AhciBusDxe in the kernel 5.0 through 5.5 in Insyde InsydeH2O. Because of an Untrusted Pointer Dereference that causes SMM memory corruption, an attacker may be able to write fixed or predictable data to SMRAM. Exploiting this issue could lead to escalating privileges to SMM."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-02-23T15:06:18.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.insyde.com/security-pledge"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.insyde.com/security-pledge/SA-2022024"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://security.netapp.com/advisory/ntap-20220222-0003/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2021-41837",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An issue was discovered in AhciBusDxe in the kernel 5.0 through 5.5 in Insyde InsydeH2O. Because of an Untrusted Pointer Dereference that causes SMM memory corruption, an attacker may be able to write fixed or predictable data to SMRAM. Exploiting this issue could lead to escalating privileges to SMM."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.insyde.com/security-pledge",
"refsource": "MISC",
"url": "https://www.insyde.com/security-pledge"
},
{
"name": "https://www.insyde.com/security-pledge/SA-2022024",
"refsource": "MISC",
"url": "https://www.insyde.com/security-pledge/SA-2022024"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
},
{
"name": "https://security.netapp.com/advisory/ntap-20220222-0003/",
"refsource": "CONFIRM",
"url": "https://security.netapp.com/advisory/ntap-20220222-0003/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2021-41837",
"datePublished": "2022-02-03T01:23:39.000Z",
"dateReserved": "2021-10-01T00:00:00.000Z",
"dateUpdated": "2026-08-11T12:22:08.782Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2021-41840 (GCVE-0-2021-41840)
Vulnerability from cvelistv5 – Published: 2022-02-03 01:20 – Updated: 2026-08-11 12:22
VLAI
EPSS
VEX
Summary
An issue was discovered in NvmExpressDxe in the kernel 5.0 through 5.5 in Insyde InsydeH2O. There is an SMM callout that allows an attacker to access the System Management Mode and execute arbitrary code. This occurs because of Inclusion of Functionality from an Untrusted Control Sphere.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
6 references
| URL | Tags |
|---|---|
| https://www.insyde.com/security-pledge | x_refsource_MISC |
| https://www.insyde.com/security-pledge/SA-2022018 | x_refsource_MISC |
| https://security.netapp.com/advisory/ntap-2022021… | x_refsource_CONFIRM |
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_CONFIRM |
| https://www.kb.cert.org/vuls/id/796611 | |
| https://cert-portal.siemens.com/productcert/html/… |
Impacted products
17 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | SIMATIC Field PG M5 |
Affected:
0 , < V22.01.10
(custom)
|
|
| Siemens | SIMATIC Field PG M6 |
Affected:
0 , < V26.01.13
(custom)
|
|
| Siemens | SIMATIC IPC127E |
Affected:
0 , < V27.01.09
(custom)
|
|
| Siemens | SIMATIC IPC227G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC277G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC277G PRO |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC327G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC377G |
Affected:
0 , < V28.01.04
(custom)
|
|
| Siemens | SIMATIC IPC427E |
Affected:
0 , < V21.01.17
(custom)
|
|
| Siemens | SIMATIC IPC477E |
Affected:
0 , < V21.01.17
(custom)
|
|
| Siemens | SIMATIC IPC477E PRO |
Affected:
0 , < V21.01.17
(custom)
|
|
| Siemens | SIMATIC IPC627E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC IPC647E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC IPC677E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC IPC847E |
Affected:
0 , < V25.02.12
(custom)
|
|
| Siemens | SIMATIC ITP1000 |
Affected:
0 , < V23.01.10
(custom)
|
|
| Siemens | SIPLUS IPC427E |
Affected:
0 , < V21.01.17
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2025-11-04T19:12:37.499Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.insyde.com/security-pledge"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.insyde.com/security-pledge/SA-2022018"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://security.netapp.com/advisory/ntap-20220217-0014/"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
},
{
"url": "https://www.kb.cert.org/vuls/id/796611"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC Field PG M5",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V22.01.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Field PG M6",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V26.01.13",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC127E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V27.01.09",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC227G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC277G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC\u00a0IPC277G PRO",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC327G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC377G",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V28.01.04",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC427E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC477E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC477E PRO",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC627E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC647E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC677E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC847E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V25.02.12",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC ITP1000",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V23.01.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS IPC427E",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21.01.17",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-08-11T12:22:12.302Z",
"orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
"shortName": "siemens-SADP"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-306654.html"
}
],
"x_adpType": "supplier"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered in NvmExpressDxe in the kernel 5.0 through 5.5 in Insyde InsydeH2O. There is an SMM callout that allows an attacker to access the System Management Mode and execute arbitrary code. This occurs because of Inclusion of Functionality from an Untrusted Control Sphere."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-02-22T19:06:58.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.insyde.com/security-pledge"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.insyde.com/security-pledge/SA-2022018"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://security.netapp.com/advisory/ntap-20220217-0014/"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2021-41840",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An issue was discovered in NvmExpressDxe in the kernel 5.0 through 5.5 in Insyde InsydeH2O. There is an SMM callout that allows an attacker to access the System Management Mode and execute arbitrary code. This occurs because of Inclusion of Functionality from an Untrusted Control Sphere."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.insyde.com/security-pledge",
"refsource": "MISC",
"url": "https://www.insyde.com/security-pledge"
},
{
"name": "https://www.insyde.com/security-pledge/SA-2022018",
"refsource": "MISC",
"url": "https://www.insyde.com/security-pledge/SA-2022018"
},
{
"name": "https://security.netapp.com/advisory/ntap-20220217-0014/",
"refsource": "CONFIRM",
"url": "https://security.netapp.com/advisory/ntap-20220217-0014/"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2021-41840",
"datePublished": "2022-02-03T01:20:07.000Z",
"dateReserved": "2021-10-01T00:00:00.000Z",
"dateUpdated": "2026-08-11T12:22:12.302Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}