    CVE-2025-2884 (GCVE-0-2025-2884)

    Vulnerability from nvd – Published: 2025-06-10 17:29 – Updated: 2026-08-11 12:22
    VLAI
    Title
    Out-of-Bounds read vulnerability in TCG TPM2.0 reference implementation
    Summary
    TCG TPM2.0 Reference implementation's CryptHmacSign helper function is vulnerable to Out-of-Bounds read due to the lack of validation the signature scheme with the signature key's algorithm. See Errata Revision 1.83 and advisory TCGVRT0009 for TCG standard TPM2.0
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial Mission & Well-being: medium
    certcc
    Decision recorded 2025-06-13 17:22 UTC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-06-13 01:41 UTC
    CWE
    Impacted products
    Vendor Product Version
    Trusted Computing Group TPM2.0 Affected: 0 , < 1.83 (custom)
    Create a notification for this product.
    Siemens SIMATIC CN 4100 Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SIMATIC Field PG M5 Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SIMATIC Field PG M6 Affected: 0 , < V26.01.14 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC BX-32A Affected: 0 , < V29.01.09 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC BX-39A Affected: 0 , < V29.01.09 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC BX-56A Affected: 0 , < V32.01.09 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC BX-59A Affected: 0 , < V32.01.09 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC MD-57A Affected: 0 , < V30.01.10 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC PX-32A Affected: 0 , < V29.01.09 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC PX-39A Affected: 0 , < V29.01.09 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC PX-39A PRO Affected: 0 , < V29.01.09 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC RW-528A Affected: 0 , < V34.01.02 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC RW-548A Affected: 0 , < V34.01.02 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC227E Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC277E Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC427E Affected: 0 , < V21.01.20 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC477E Affected: 0 , < V21.01.20 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC477E PRO Affected: 0 , < V21.01.20 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC627E Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC647E Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC677E Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC847E Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SIMATIC ITP1000 Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SIPLUS IPC427E Affected: 0 , < V21.01.20 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2025-06-10T19:02:29.811Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-01209.html"
              },
              {
                "url": "https://www.kb.cert.org/vuls/id/282450"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "LOCAL",
                  "availabilityImpact": "HIGH",
                  "baseScore": 6.6,
                  "baseSeverity": "MEDIUM",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "NONE",
                  "privilegesRequired": "LOW",
                  "scope": "UNCHANGED",
                  "userInteraction": "REQUIRED",
                  "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:N/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-2884",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-06-13T01:41:10.489446Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-125",
                    "description": "CWE-125 Out-of-bounds Read",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-06-13T01:46:13.802Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "affected": [
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC CN 4100",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC Field PG M5",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC Field PG M6",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V26.01.14",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC BX-32A",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V29.01.09",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC BX-39A",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V29.01.09",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC BX-56A",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V32.01.09",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC BX-59A",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V32.01.09",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC MD-57A",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V30.01.10",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC PX-32A",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V29.01.09",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC PX-39A",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V29.01.09",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC PX-39A PRO",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V29.01.09",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC RW-528A",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V34.01.02",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC RW-548A",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V34.01.02",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC227E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC277E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC427E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.20",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC477E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.20",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC477E PRO",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.20",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC627E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC647E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC677E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC847E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC ITP1000",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS IPC427E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.20",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-08-11T12:22:36.753Z",
              "orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
              "shortName": "siemens-SADP"
            },
            "references": [
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-628843.html"
              }
            ],
            "x_adpType": "supplier"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "TPM2.0",
              "vendor": "Trusted Computing Group",
              "versions": [
                {
                  "lessThan": "1.83",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "TCG TPM2.0 Reference implementation\u0027s CryptHmacSign helper function is vulnerable to Out-of-Bounds read due to the lack of validation the signature scheme with the signature key\u0027s algorithm. See Errata Revision 1.83 and advisory TCGVRT0009 for TCG standard TPM2.0"
            }
          ],
          "metrics": [
            {
              "other": {
                "content": {
                  "id": "CVE-2025-2884",
                  "selections": [
                    {
                      "name": "Exploitation",
                      "namespace": "ssvc",
                      "values": [
                        "none"
                      ],
                      "version": "1.0.0"
                    },
                    {
                      "name": "Automatable",
                      "namespace": "ssvc",
                      "values": [
                        "no"
                      ],
                      "version": "2.0.0"
                    },
                    {
                      "name": "Technical Impact",
                      "namespace": "ssvc",
                      "values": [
                        "partial"
                      ],
                      "version": "1.0.0"
                    },
                    {
                      "name": "Mission \u0026 Well-being",
                      "namespace": "ssvc",
                      "values": [
                        "medium"
                      ],
                      "version": "1.0.0"
                    }
                  ],
                  "timestamp": "2025-06-13T17:22:30.584Z"
                },
                "type": "ssvcV1_0_1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "CWE-125 Out-of-bounds Read",
                  "lang": "en"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-06-13T18:22:21.856Z",
            "orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
            "shortName": "certcc"
          },
          "references": [
            {
              "url": "https://trustedcomputinggroup.org/about/security/"
            },
            {
              "name": "TPM2.0 Errata",
              "url": "https://trustedcomputinggroup.org/wp-content/uploads/TPM2.0-Library-Spec-v1.83-Errata_v1_pub.pdf"
            },
            {
              "name": "Vendor Advisory",
              "url": "https://trustedcomputinggroup.org/wp-content/uploads/VRT0009-Advisory-FINAL.pdf"
            },
            {
              "name": "Vendor Patch",
              "url": "https://github.com/stefanberger/libtpms/commit/04b2d8e9afc0a9b6bffe562a23e58c0de11532d1"
            },
            {
              "name": "Related CVE",
              "url": "https://www.cve.org/CVERecord?id=CVE-2025-49133"
            }
          ],
          "source": {
            "discovery": "INTERNAL"
          },
          "title": "Out-of-Bounds read vulnerability in TCG TPM2.0 reference implementation",
          "x_generator": {
            "engine": "VINCE 3.0.20",
            "env": "prod",
            "origin": "https://cveawg.mitre.org/api/cve/CVE-2025-2884"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
        "assignerShortName": "certcc",
        "cveId": "CVE-2025-2884",
        "datePublished": "2025-06-10T17:29:19.463Z",
        "dateReserved": "2025-03-27T21:01:41.908Z",
        "dateUpdated": "2026-08-11T12:22:36.753Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2022-21198 (GCVE-0-2022-21198)

    Vulnerability from nvd – Published: 2022-11-11 15:49 – Updated: 2026-08-11 12:22
    VLAI
    Summary
    Time-of-check time-of-use race condition in the BIOS firmware for some Intel(R) Processors may allow a privileged user to potentially enable escalation of privilege via local access.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-01-29 20:38 UTC
    CWE
    • escalation of privilege
    • CWE-367 - Time-of-check Time-of-use (TOCTOU) Race Condition
    Impacted products
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T02:31:59.787Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00688.html",
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00688.html"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-21198",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-01-29T20:38:21.227981Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-367",
                    "description": "CWE-367 Time-of-check Time-of-use (TOCTOU) Race Condition",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-02-04T17:58:34.848Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "affected": [
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC Field PG M5",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V22.01.11",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC Field PG M6",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V26.01.11",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC BX-39A",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V29.01.03",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC PX-39A",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V29.01.03",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC PX-39A PRO",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V29.01.03",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC427E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.19",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC477E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.19",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC477E PRO",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.19",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC627E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.14",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC647E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.14",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC677E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.14",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC847E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.14",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC ITP1000",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS IPC427E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.19",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-08-11T12:22:27.669Z",
              "orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
              "shortName": "siemens-SADP"
            },
            "references": [
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-686975.html"
              }
            ],
            "x_adpType": "supplier"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Intel(R) Processors",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "See references"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Time-of-check time-of-use race condition in the BIOS firmware for some Intel(R) Processors may allow a privileged user to potentially enable escalation of privilege via local access."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 7.9,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:N/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "escalation of privilege",
                  "lang": "en"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-11-14T17:46:28.257Z",
            "orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
            "shortName": "intel"
          },
          "references": [
            {
              "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00688.html",
              "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00688.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
        "assignerShortName": "intel",
        "cveId": "CVE-2022-21198",
        "datePublished": "2022-11-11T15:49:10.831Z",
        "dateReserved": "2022-02-18T21:23:59.775Z",
        "dateUpdated": "2026-08-11T12:22:27.669Z",
        "requesterUserId": "524a9a6b-3515-4b97-ab85-1a9a79493852",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2022-24031 (GCVE-0-2022-24031)

    Vulnerability from nvd – Published: 2022-02-03 01:59 – Updated: 2026-08-11 12:22
    VLAI
    Summary
    An issue was discovered in NvmExpressDxe in Insyde InsydeH2O with kernel 5.1 through 5.5. An SMM memory corruption vulnerability allows an attacker to write fixed or predictable data to SMRAM. Exploiting this issue could lead to escalating privileges to SMM.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Impacted products
    Vendor Product Version
    Siemens RUGGEDCOM APE1808 - BIOS Affected: 0 , < V1.0.202N (custom)
    Create a notification for this product.
    Siemens SIMATIC Field PG M5 Affected: 0 , < V22.01.10 (custom)
    Create a notification for this product.
    Siemens SIMATIC Field PG M6 Affected: 0 , < V26.01.13 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC127E Affected: 0 , < V27.01.09 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC227G Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC277G Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC277G PRO Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC327G Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC377G Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC427E Affected: 0 , < V21.01.17 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC477E Affected: 0 , < V21.01.17 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC477E PRO Affected: 0 , < V21.01.17 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC627E Affected: 0 , < V25.02.12 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC647E Affected: 0 , < V25.02.12 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC677E Affected: 0 , < V25.02.12 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC847E Affected: 0 , < V25.02.12 (custom)
    Create a notification for this product.
    Siemens SIMATIC ITP1000 Affected: 0 , < V23.01.10 (custom)
    Create a notification for this product.
    Siemens SIPLUS IPC427E Affected: 0 , < V21.01.17 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2025-11-04T19:12:59.895Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.insyde.com/security-pledge"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.insyde.com/security-pledge/SA-2022015"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://security.netapp.com/advisory/ntap-20220216-0009/"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
              },
              {
                "url": "https://www.kb.cert.org/vuls/id/796611"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "affected": [
              {
                "defaultStatus": "unknown",
                "product": "RUGGEDCOM APE1808 - BIOS",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V1.0.202N",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC Field PG M5",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V22.01.10",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC Field PG M6",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V26.01.13",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC127E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V27.01.09",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC227G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC277G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC\u00a0IPC277G PRO",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC327G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC377G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC427E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.17",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC477E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.17",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC477E PRO",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.17",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC627E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.12",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC647E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.12",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC677E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.12",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC847E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.12",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC ITP1000",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V23.01.10",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS IPC427E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.17",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-08-11T12:22:29.973Z",
              "orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
              "shortName": "siemens-SADP"
            },
            "references": [
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-306654.html"
              }
            ],
            "x_adpType": "supplier"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "An issue was discovered in NvmExpressDxe in Insyde InsydeH2O with kernel 5.1 through 5.5. An SMM memory corruption vulnerability allows an attacker to write fixed or predictable data to SMRAM. Exploiting this issue could lead to escalating privileges to SMM."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-02-22T19:06:47.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.insyde.com/security-pledge"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.insyde.com/security-pledge/SA-2022015"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://security.netapp.com/advisory/ntap-20220216-0009/"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2022-24031",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "An issue was discovered in NvmExpressDxe in Insyde InsydeH2O with kernel 5.1 through 5.5. An SMM memory corruption vulnerability allows an attacker to write fixed or predictable data to SMRAM. Exploiting this issue could lead to escalating privileges to SMM."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.insyde.com/security-pledge",
                  "refsource": "MISC",
                  "url": "https://www.insyde.com/security-pledge"
                },
                {
                  "name": "https://www.insyde.com/security-pledge/SA-2022015",
                  "refsource": "MISC",
                  "url": "https://www.insyde.com/security-pledge/SA-2022015"
                },
                {
                  "name": "https://security.netapp.com/advisory/ntap-20220216-0009/",
                  "refsource": "CONFIRM",
                  "url": "https://security.netapp.com/advisory/ntap-20220216-0009/"
                },
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf",
                  "refsource": "CONFIRM",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2022-24031",
        "datePublished": "2022-02-03T01:59:49.000Z",
        "dateReserved": "2022-01-26T00:00:00.000Z",
        "dateUpdated": "2026-08-11T12:22:29.973Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2022-24030 (GCVE-0-2022-24030)

    Vulnerability from nvd – Published: 2022-02-03 01:16 – Updated: 2026-08-11 12:22
    VLAI
    Summary
    An issue was discovered in AhciBusDxe in Insyde InsydeH2O with kernel 5.1 through 5.5. An SMM memory corruption vulnerability allows an attacker to write fixed or predictable data to SMRAM. Exploiting this issue could lead to escalating privileges to SMM.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Impacted products
    Vendor Product Version
    Siemens RUGGEDCOM APE1808 - BIOS Affected: 0 , < V1.0.202N (custom)
    Create a notification for this product.
    Siemens SIMATIC Field PG M5 Affected: 0 , < V22.01.10 (custom)
    Create a notification for this product.
    Siemens SIMATIC Field PG M6 Affected: 0 , < V26.01.13 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC127E Affected: 0 , < V27.01.09 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC227G Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC277G Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC277G PRO Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC327G Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC377G Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC427E Affected: 0 , < V21.01.17 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC477E Affected: 0 , < V21.01.17 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC477E PRO Affected: 0 , < V21.01.17 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC627E Affected: 0 , < V25.02.12 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC647E Affected: 0 , < V25.02.12 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC677E Affected: 0 , < V25.02.12 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC847E Affected: 0 , < V25.02.12 (custom)
    Create a notification for this product.
    Siemens SIMATIC ITP1000 Affected: 0 , < V23.01.10 (custom)
    Create a notification for this product.
    Siemens SIPLUS IPC427E Affected: 0 , < V21.01.17 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2025-11-04T19:12:58.761Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.insyde.com/security-pledge"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.insyde.com/security-pledge/SA-2022011"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://security.netapp.com/advisory/ntap-20220216-0011/"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
              },
              {
                "url": "https://www.kb.cert.org/vuls/id/796611"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "affected": [
              {
                "defaultStatus": "unknown",
                "product": "RUGGEDCOM APE1808 - BIOS",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V1.0.202N",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC Field PG M5",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V22.01.10",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC Field PG M6",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V26.01.13",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC127E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V27.01.09",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC227G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC277G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC\u00a0IPC277G PRO",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC327G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC377G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC427E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.17",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC477E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.17",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC477E PRO",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.17",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC627E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.12",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC647E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.12",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC677E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.12",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC847E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.12",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC ITP1000",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V23.01.10",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS IPC427E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.17",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-08-11T12:22:28.819Z",
              "orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
              "shortName": "siemens-SADP"
            },
            "references": [
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-306654.html"
              }
            ],
            "x_adpType": "supplier"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "An issue was discovered in AhciBusDxe in Insyde InsydeH2O with kernel 5.1 through 5.5. An SMM memory corruption vulnerability allows an attacker to write fixed or predictable data to SMRAM. Exploiting this issue could lead to escalating privileges to SMM."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-02-22T19:07:07.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.insyde.com/security-pledge"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.insyde.com/security-pledge/SA-2022011"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://security.netapp.com/advisory/ntap-20220216-0011/"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2022-24030",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "An issue was discovered in AhciBusDxe in Insyde InsydeH2O with kernel 5.1 through 5.5. An SMM memory corruption vulnerability allows an attacker to write fixed or predictable data to SMRAM. Exploiting this issue could lead to escalating privileges to SMM."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.insyde.com/security-pledge",
                  "refsource": "MISC",
                  "url": "https://www.insyde.com/security-pledge"
                },
                {
                  "name": "https://www.insyde.com/security-pledge/SA-2022011",
                  "refsource": "MISC",
                  "url": "https://www.insyde.com/security-pledge/SA-2022011"
                },
                {
                  "name": "https://security.netapp.com/advisory/ntap-20220216-0011/",
                  "refsource": "CONFIRM",
                  "url": "https://security.netapp.com/advisory/ntap-20220216-0011/"
                },
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf",
                  "refsource": "CONFIRM",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2022-24030",
        "datePublished": "2022-02-03T01:16:51.000Z",
        "dateReserved": "2022-01-26T00:00:00.000Z",
        "dateUpdated": "2026-08-11T12:22:28.819Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2021-43615 (GCVE-0-2021-43615)

    Vulnerability from nvd – Published: 2022-02-03 01:09 – Updated: 2026-08-11 12:22
    VLAI
    Summary
    An issue was discovered in HddPassword in Insyde InsydeH2O with kernel 5.1 before 05.16.23, 5.2 before 05.26.23, 5.3 before 05.35.23, 5.4 before 05.43.22, and 5.5 before 05.51.22. An SMM memory corruption vulnerability allows an attacker to write fixed or predictable data to SMRAM. Exploiting this issue could lead to escalating privileges to SMM.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Impacted products
    Vendor Product Version
    Siemens RUGGEDCOM APE1808 - BIOS Affected: 0 , < V1.0.202N (custom)
    Create a notification for this product.
    Siemens SIMATIC Field PG M5 Affected: 0 , < V22.01.10 (custom)
    Create a notification for this product.
    Siemens SIMATIC Field PG M6 Affected: 0 , < V26.01.13 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC127E Affected: 0 , < V27.01.09 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC227G Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC277G Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC277G PRO Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC327G Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC377G Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC427E Affected: 0 , < V21.01.17 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC477E Affected: 0 , < V21.01.17 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC477E PRO Affected: 0 , < V21.01.17 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC627E Affected: 0 , < V25.02.12 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC647E Affected: 0 , < V25.02.12 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC677E Affected: 0 , < V25.02.12 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC847E Affected: 0 , < V25.02.12 (custom)
    Create a notification for this product.
    Siemens SIMATIC ITP1000 Affected: 0 , < V23.01.10 (custom)
    Create a notification for this product.
    Siemens SIPLUS IPC427E Affected: 0 , < V21.01.17 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2025-11-04T19:12:46.366Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.insyde.com/security-pledge"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.insyde.com/security-pledge/SA-2022013"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://security.netapp.com/advisory/ntap-20220216-0010/"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
              },
              {
                "url": "https://www.kb.cert.org/vuls/id/796611"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "affected": [
              {
                "defaultStatus": "unknown",
                "product": "RUGGEDCOM APE1808 - BIOS",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V1.0.202N",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC Field PG M5",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V22.01.10",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC Field PG M6",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V26.01.13",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC127E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V27.01.09",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC227G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC277G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC\u00a0IPC277G PRO",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC327G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC377G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC427E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.17",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC477E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.17",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC477E PRO",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.17",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC627E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.12",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC647E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.12",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC677E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.12",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC847E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.12",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC ITP1000",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V23.01.10",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS IPC427E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.17",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-08-11T12:22:22.919Z",
              "orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
              "shortName": "siemens-SADP"
            },
            "references": [
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-306654.html"
              }
            ],
            "x_adpType": "supplier"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "An issue was discovered in HddPassword in Insyde InsydeH2O with kernel 5.1 before 05.16.23, 5.2 before 05.26.23, 5.3 before 05.35.23, 5.4 before 05.43.22, and 5.5 before 05.51.22. An SMM memory corruption vulnerability allows an attacker to write fixed or predictable data to SMRAM. Exploiting this issue could lead to escalating privileges to SMM."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-02-22T19:06:51.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.insyde.com/security-pledge"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.insyde.com/security-pledge/SA-2022013"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://security.netapp.com/advisory/ntap-20220216-0010/"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2021-43615",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "An issue was discovered in HddPassword in Insyde InsydeH2O with kernel 5.1 before 05.16.23, 5.2 before 05.26.23, 5.3 before 05.35.23, 5.4 before 05.43.22, and 5.5 before 05.51.22. An SMM memory corruption vulnerability allows an attacker to write fixed or predictable data to SMRAM. Exploiting this issue could lead to escalating privileges to SMM."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.insyde.com/security-pledge",
                  "refsource": "MISC",
                  "url": "https://www.insyde.com/security-pledge"
                },
                {
                  "name": "https://www.insyde.com/security-pledge/SA-2022013",
                  "refsource": "MISC",
                  "url": "https://www.insyde.com/security-pledge/SA-2022013"
                },
                {
                  "name": "https://security.netapp.com/advisory/ntap-20220216-0010/",
                  "refsource": "CONFIRM",
                  "url": "https://security.netapp.com/advisory/ntap-20220216-0010/"
                },
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf",
                  "refsource": "CONFIRM",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2021-43615",
        "datePublished": "2022-02-03T01:09:57.000Z",
        "dateReserved": "2021-11-13T00:00:00.000Z",
        "dateUpdated": "2026-08-11T12:22:22.919Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2021-43323 (GCVE-0-2021-43323)

    Vulnerability from nvd – Published: 2022-02-03 01:50 – Updated: 2026-08-11 12:22
    VLAI
    Summary
    An issue was discovered in UsbCoreDxe in Insyde InsydeH2O with kernel 5.5 before 05.51.45, 5.4 before 05.43.45, 5.3 before 05.35.45, 5.2 before 05.26.45, 5.1 before 05.16.45, and 5.0 before 05.08.45. An SMM callout vulnerability allows an attacker to hijack execution flow of code running in System Management Mode. Exploiting this issue could lead to escalating privileges to SMM.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Impacted products
    Vendor Product Version
    Siemens RUGGEDCOM APE1808 - BIOS Affected: 0 , < V1.0.202N (custom)
    Create a notification for this product.
    Siemens SIMATIC Field PG M5 Affected: 0 , < V22.01.10 (custom)
    Create a notification for this product.
    Siemens SIMATIC Field PG M6 Affected: 0 , < V26.01.13 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC127E Affected: 0 , < V27.01.09 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC227G Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC277G Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC277G PRO Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC327G Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC377G Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC427E Affected: 0 , < V21.01.17 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC477E Affected: 0 , < V21.01.17 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC477E PRO Affected: 0 , < V21.01.17 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC627E Affected: 0 , < V25.02.12 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC647E Affected: 0 , < V25.02.12 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC677E Affected: 0 , < V25.02.12 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC847E Affected: 0 , < V25.02.12 (custom)
    Create a notification for this product.
    Siemens SIMATIC ITP1000 Affected: 0 , < V23.01.10 (custom)
    Create a notification for this product.
    Siemens SIPLUS IPC427E Affected: 0 , < V21.01.17 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2025-11-04T19:12:44.192Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.insyde.com/security-pledge"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://security.netapp.com/advisory/ntap-20220217-0013/"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
              },
              {
                "url": "https://www.kb.cert.org/vuls/id/796611"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "affected": [
              {
                "defaultStatus": "unknown",
                "product": "RUGGEDCOM APE1808 - BIOS",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V1.0.202N",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC Field PG M5",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V22.01.10",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC Field PG M6",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V26.01.13",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC127E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V27.01.09",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC227G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC277G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC\u00a0IPC277G PRO",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC327G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC377G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC427E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.17",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC477E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.17",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC477E PRO",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.17",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC627E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.12",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC647E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.12",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC677E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.12",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC847E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.12",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC ITP1000",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V23.01.10",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS IPC427E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.17",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-08-11T12:22:19.420Z",
              "orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
              "shortName": "siemens-SADP"
            },
            "references": [
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-306654.html"
              }
            ],
            "x_adpType": "supplier"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "An issue was discovered in UsbCoreDxe in Insyde InsydeH2O with kernel 5.5 before 05.51.45, 5.4 before 05.43.45, 5.3 before 05.35.45, 5.2 before 05.26.45, 5.1 before 05.16.45, and 5.0 before 05.08.45. An SMM callout vulnerability allows an attacker to hijack execution flow of code running in System Management Mode. Exploiting this issue could lead to escalating privileges to SMM."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-02-22T19:06:29.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.insyde.com/security-pledge"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://security.netapp.com/advisory/ntap-20220217-0013/"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2021-43323",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "An issue was discovered in UsbCoreDxe in Insyde InsydeH2O with kernel 5.5 before 05.51.45, 5.4 before 05.43.45, 5.3 before 05.35.45, 5.2 before 05.26.45, 5.1 before 05.16.45, and 5.0 before 05.08.45. An SMM callout vulnerability allows an attacker to hijack execution flow of code running in System Management Mode. Exploiting this issue could lead to escalating privileges to SMM."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.insyde.com/security-pledge",
                  "refsource": "MISC",
                  "url": "https://www.insyde.com/security-pledge"
                },
                {
                  "name": "https://security.netapp.com/advisory/ntap-20220217-0013/",
                  "refsource": "CONFIRM",
                  "url": "https://security.netapp.com/advisory/ntap-20220217-0013/"
                },
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf",
                  "refsource": "CONFIRM",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2021-43323",
        "datePublished": "2022-02-03T01:50:01.000Z",
        "dateReserved": "2021-11-03T00:00:00.000Z",
        "dateUpdated": "2026-08-11T12:22:19.420Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2021-42554 (GCVE-0-2021-42554)

    Vulnerability from nvd – Published: 2022-02-03 01:40 – Updated: 2026-08-11 12:22
    VLAI
    Summary
    An issue was discovered in Insyde InsydeH2O with Kernel 5.0 before 05.08.42, Kernel 5.1 before 05.16.42, Kernel 5.2 before 05.26.42, Kernel 5.3 before 05.35.42, Kernel 5.4 before 05.42.51, and Kernel 5.5 before 05.50.51. An SMM memory corruption vulnerability in FvbServicesRuntimeDxe allows a possible attacker to write fixed or predictable data to SMRAM. Exploiting this issue could lead to escalating privileges to SMM.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Impacted products
    Vendor Product Version
    Siemens RUGGEDCOM APE1808 - BIOS Affected: 0 , < V1.0.202N (custom)
    Create a notification for this product.
    Siemens SIMATIC Field PG M5 Affected: 0 , < V22.01.10 (custom)
    Create a notification for this product.
    Siemens SIMATIC Field PG M6 Affected: 0 , < V26.01.13 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC127E Affected: 0 , < V27.01.09 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC227G Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC277G Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC277G PRO Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC327G Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC377G Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC427E Affected: 0 , < V21.01.17 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC477E Affected: 0 , < V21.01.17 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC477E PRO Affected: 0 , < V21.01.17 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC627E Affected: 0 , < V25.02.12 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC647E Affected: 0 , < V25.02.12 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC677E Affected: 0 , < V25.02.12 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC847E Affected: 0 , < V25.02.12 (custom)
    Create a notification for this product.
    Siemens SIMATIC ITP1000 Affected: 0 , < V23.01.10 (custom)
    Create a notification for this product.
    Siemens SIPLUS IPC427E Affected: 0 , < V21.01.17 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2025-11-04T19:12:43.116Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.insyde.com/security-pledge"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.insyde.com/security-pledge/SA-2022012"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://security.netapp.com/advisory/ntap-20220216-0007/"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
              },
              {
                "url": "https://www.kb.cert.org/vuls/id/796611"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "affected": [
              {
                "defaultStatus": "unknown",
                "product": "RUGGEDCOM APE1808 - BIOS",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V1.0.202N",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC Field PG M5",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V22.01.10",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC Field PG M6",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V26.01.13",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC127E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V27.01.09",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC227G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC277G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC\u00a0IPC277G PRO",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC327G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC377G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC427E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.17",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC477E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.17",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC477E PRO",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.17",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC627E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.12",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC647E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.12",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC677E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.12",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC847E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.12",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC ITP1000",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V23.01.10",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS IPC427E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.17",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-08-11T12:22:18.229Z",
              "orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
              "shortName": "siemens-SADP"
            },
            "references": [
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-306654.html"
              }
            ],
            "x_adpType": "supplier"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "An issue was discovered in Insyde InsydeH2O with Kernel 5.0 before 05.08.42, Kernel 5.1 before 05.16.42, Kernel 5.2 before 05.26.42, Kernel 5.3 before 05.35.42, Kernel 5.4 before 05.42.51, and Kernel 5.5 before 05.50.51. An SMM memory corruption vulnerability in FvbServicesRuntimeDxe allows a possible attacker to write fixed or predictable data to SMRAM. Exploiting this issue could lead to escalating privileges to SMM."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-02-22T19:06:40.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.insyde.com/security-pledge"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.insyde.com/security-pledge/SA-2022012"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://security.netapp.com/advisory/ntap-20220216-0007/"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2021-42554",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "An issue was discovered in Insyde InsydeH2O with Kernel 5.0 before 05.08.42, Kernel 5.1 before 05.16.42, Kernel 5.2 before 05.26.42, Kernel 5.3 before 05.35.42, Kernel 5.4 before 05.42.51, and Kernel 5.5 before 05.50.51. An SMM memory corruption vulnerability in FvbServicesRuntimeDxe allows a possible attacker to write fixed or predictable data to SMRAM. Exploiting this issue could lead to escalating privileges to SMM."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.insyde.com/security-pledge",
                  "refsource": "MISC",
                  "url": "https://www.insyde.com/security-pledge"
                },
                {
                  "name": "https://www.insyde.com/security-pledge/SA-2022012",
                  "refsource": "MISC",
                  "url": "https://www.insyde.com/security-pledge/SA-2022012"
                },
                {
                  "name": "https://security.netapp.com/advisory/ntap-20220216-0007/",
                  "refsource": "CONFIRM",
                  "url": "https://security.netapp.com/advisory/ntap-20220216-0007/"
                },
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf",
                  "refsource": "CONFIRM",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2021-42554",
        "datePublished": "2022-02-03T01:40:56.000Z",
        "dateReserved": "2021-10-18T00:00:00.000Z",
        "dateUpdated": "2026-08-11T12:22:18.229Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2021-42113 (GCVE-0-2021-42113)

    Vulnerability from nvd – Published: 2022-02-03 01:46 – Updated: 2026-08-11 12:22
    VLAI
    Summary
    An issue was discovered in StorageSecurityCommandDxe in Insyde InsydeH2O with Kernel 5.1 before 05.14.28, Kernel 5.2 before 05.24.28, and Kernel 5.3 before 05.32.25. An SMM callout vulnerability allows an attacker to hijack execution flow of code running in System Management Mode. Exploiting this issue could lead to escalating privileges to SMM.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Impacted products
    Vendor Product Version
    Siemens RUGGEDCOM APE1808 - BIOS Affected: 0 , < V1.0.202N (custom)
    Create a notification for this product.
    Siemens SIMATIC Field PG M5 Affected: 0 , < V22.01.10 (custom)
    Create a notification for this product.
    Siemens SIMATIC Field PG M6 Affected: 0 , < V26.01.13 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC127E Affected: 0 , < V27.01.09 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC227G Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC277G Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC277G PRO Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC327G Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC377G Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC427E Affected: 0 , < V21.01.17 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC477E Affected: 0 , < V21.01.17 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC477E PRO Affected: 0 , < V21.01.17 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC627E Affected: 0 , < V25.02.12 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC647E Affected: 0 , < V25.02.12 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC677E Affected: 0 , < V25.02.12 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC847E Affected: 0 , < V25.02.12 (custom)
    Create a notification for this product.
    Siemens SIMATIC ITP1000 Affected: 0 , < V23.01.10 (custom)
    Create a notification for this product.
    Siemens SIPLUS IPC427E Affected: 0 , < V21.01.17 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2025-11-04T19:12:42.015Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.insyde.com/security-pledge"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.insyde.com/security-pledge/SA-2022008"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://security.netapp.com/advisory/ntap-20220216-0012/"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
              },
              {
                "url": "https://www.kb.cert.org/vuls/id/796611"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "affected": [
              {
                "defaultStatus": "unknown",
                "product": "RUGGEDCOM APE1808 - BIOS",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V1.0.202N",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC Field PG M5",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V22.01.10",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC Field PG M6",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V26.01.13",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC127E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V27.01.09",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC227G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC277G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC\u00a0IPC277G PRO",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC327G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC377G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC427E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.17",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC477E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.17",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC477E PRO",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.17",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC627E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.12",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC647E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.12",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC677E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.12",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC847E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.12",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC ITP1000",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V23.01.10",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS IPC427E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.17",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-08-11T12:22:17.067Z",
              "orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
              "shortName": "siemens-SADP"
            },
            "references": [
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-306654.html"
              }
            ],
            "x_adpType": "supplier"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "An issue was discovered in StorageSecurityCommandDxe in Insyde InsydeH2O with Kernel 5.1 before 05.14.28, Kernel 5.2 before 05.24.28, and Kernel 5.3 before 05.32.25. An SMM callout vulnerability allows an attacker to hijack execution flow of code running in System Management Mode. Exploiting this issue could lead to escalating privileges to SMM."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-02-22T19:06:49.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.insyde.com/security-pledge"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.insyde.com/security-pledge/SA-2022008"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://security.netapp.com/advisory/ntap-20220216-0012/"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2021-42113",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "An issue was discovered in StorageSecurityCommandDxe in Insyde InsydeH2O with Kernel 5.1 before 05.14.28, Kernel 5.2 before 05.24.28, and Kernel 5.3 before 05.32.25. An SMM callout vulnerability allows an attacker to hijack execution flow of code running in System Management Mode. Exploiting this issue could lead to escalating privileges to SMM."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.insyde.com/security-pledge",
                  "refsource": "MISC",
                  "url": "https://www.insyde.com/security-pledge"
                },
                {
                  "name": "https://www.insyde.com/security-pledge/SA-2022008",
                  "refsource": "MISC",
                  "url": "https://www.insyde.com/security-pledge/SA-2022008"
                },
                {
                  "name": "https://security.netapp.com/advisory/ntap-20220216-0012/",
                  "refsource": "CONFIRM",
                  "url": "https://security.netapp.com/advisory/ntap-20220216-0012/"
                },
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf",
                  "refsource": "CONFIRM",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2021-42113",
        "datePublished": "2022-02-03T01:46:08.000Z",
        "dateReserved": "2021-10-08T00:00:00.000Z",
        "dateUpdated": "2026-08-11T12:22:17.067Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2021-42060 (GCVE-0-2021-42060)

    Vulnerability from nvd – Published: 2022-02-03 01:27 – Updated: 2026-08-11 12:22
    VLAI
    Summary
    An issue was discovered in Insyde InsydeH2O Kernel 5.0 through 05.08.41, Kernel 5.1 through 05.16.41, Kernel 5.2 before 05.23.22, and Kernel 5.3 before 05.32.22. An Int15ServiceSmm SMM callout vulnerability allows an attacker to hijack execution flow of code running in System Management Mode. Exploiting this issue could lead to escalating privileges to SMM.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Impacted products
    Vendor Product Version
    Siemens RUGGEDCOM APE1808 - BIOS Affected: 0 , < V1.0.202N (custom)
    Create a notification for this product.
    Siemens SIMATIC Field PG M5 Affected: 0 , < V22.01.10 (custom)
    Create a notification for this product.
    Siemens SIMATIC Field PG M6 Affected: 0 , < V26.01.13 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC127E Affected: 0 , < V27.01.09 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC227G Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC277G Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC277G PRO Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC327G Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC377G Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC427E Affected: 0 , < V21.01.17 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC477E Affected: 0 , < V21.01.17 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC477E PRO Affected: 0 , < V21.01.17 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC627E Affected: 0 , < V25.02.12 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC647E Affected: 0 , < V25.02.12 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC677E Affected: 0 , < V25.02.12 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC847E Affected: 0 , < V25.02.12 (custom)
    Create a notification for this product.
    Siemens SIMATIC ITP1000 Affected: 0 , < V23.01.10 (custom)
    Create a notification for this product.
    Siemens SIPLUS IPC427E Affected: 0 , < V21.01.17 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2025-11-04T19:12:40.921Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.insyde.com/security-pledge"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.insyde.com/security-pledge/SA-2022007"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://security.netapp.com/advisory/ntap-20220217-0015/"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
              },
              {
                "url": "https://www.kb.cert.org/vuls/id/796611"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "affected": [
              {
                "defaultStatus": "unknown",
                "product": "RUGGEDCOM APE1808 - BIOS",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V1.0.202N",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC Field PG M5",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V22.01.10",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC Field PG M6",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V26.01.13",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC127E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V27.01.09",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC227G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC277G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC\u00a0IPC277G PRO",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC327G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC377G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC427E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.17",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC477E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.17",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC477E PRO",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.17",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC627E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.12",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC647E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.12",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC677E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.12",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC847E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.12",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC ITP1000",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V23.01.10",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS IPC427E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.17",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-08-11T12:22:15.909Z",
              "orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
              "shortName": "siemens-SADP"
            },
            "references": [
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-306654.html"
              }
            ],
            "x_adpType": "supplier"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "An issue was discovered in Insyde InsydeH2O Kernel 5.0 through 05.08.41, Kernel 5.1 through 05.16.41, Kernel 5.2 before 05.23.22, and Kernel 5.3 before 05.32.22. An Int15ServiceSmm SMM callout vulnerability allows an attacker to hijack execution flow of code running in System Management Mode. Exploiting this issue could lead to escalating privileges to SMM."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-02-22T19:06:42.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.insyde.com/security-pledge"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.insyde.com/security-pledge/SA-2022007"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://security.netapp.com/advisory/ntap-20220217-0015/"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2021-42060",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "An issue was discovered in Insyde InsydeH2O Kernel 5.0 through 05.08.41, Kernel 5.1 through 05.16.41, Kernel 5.2 before 05.23.22, and Kernel 5.3 before 05.32.22. An Int15ServiceSmm SMM callout vulnerability allows an attacker to hijack execution flow of code running in System Management Mode. Exploiting this issue could lead to escalating privileges to SMM."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.insyde.com/security-pledge",
                  "refsource": "MISC",
                  "url": "https://www.insyde.com/security-pledge"
                },
                {
                  "name": "https://www.insyde.com/security-pledge/SA-2022007",
                  "refsource": "MISC",
                  "url": "https://www.insyde.com/security-pledge/SA-2022007"
                },
                {
                  "name": "https://security.netapp.com/advisory/ntap-20220217-0015/",
                  "refsource": "CONFIRM",
                  "url": "https://security.netapp.com/advisory/ntap-20220217-0015/"
                },
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf",
                  "refsource": "CONFIRM",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2021-42060",
        "datePublished": "2022-02-03T01:27:34.000Z",
        "dateReserved": "2021-10-07T00:00:00.000Z",
        "dateUpdated": "2026-08-11T12:22:15.909Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2021-42059 (GCVE-0-2021-42059)

    Vulnerability from nvd – Published: 2022-02-03 01:13 – Updated: 2026-08-11 12:22
    VLAI
    Summary
    An issue was discovered in Insyde InsydeH2O Kernel 5.0 before 05.08.41, Kernel 5.1 before 05.16.41, Kernel 5.2 before 05.26.41, Kernel 5.3 before 05.35.41, and Kernel 5.4 before 05.42.20. A stack-based buffer overflow leads toarbitrary code execution in UEFI DisplayTypeDxe DXE driver.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Impacted products
    Vendor Product Version
    Siemens RUGGEDCOM APE1808 - BIOS Affected: 0 , < V1.0.202N (custom)
    Create a notification for this product.
    Siemens SIMATIC Field PG M5 Affected: 0 , < V22.01.10 (custom)
    Create a notification for this product.
    Siemens SIMATIC Field PG M6 Affected: 0 , < V26.01.13 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC127E Affected: 0 , < V27.01.09 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC227G Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC277G Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC277G PRO Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC327G Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC377G Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC427E Affected: 0 , < V21.01.17 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC477E Affected: 0 , < V21.01.17 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC477E PRO Affected: 0 , < V21.01.17 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC627E Affected: 0 , < V25.02.12 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC647E Affected: 0 , < V25.02.12 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC677E Affected: 0 , < V25.02.12 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC847E Affected: 0 , < V25.02.12 (custom)
    Create a notification for this product.
    Siemens SIMATIC ITP1000 Affected: 0 , < V23.01.10 (custom)
    Create a notification for this product.
    Siemens SIPLUS IPC427E Affected: 0 , < V21.01.17 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2025-11-04T19:12:39.726Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.insyde.com/security-pledge"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.insyde.com/security-pledge/SA-2022006"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://security.netapp.com/advisory/ntap-20220216-0008/"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
              },
              {
                "url": "https://www.kb.cert.org/vuls/id/796611"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "affected": [
              {
                "defaultStatus": "unknown",
                "product": "RUGGEDCOM APE1808 - BIOS",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V1.0.202N",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC Field PG M5",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V22.01.10",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC Field PG M6",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V26.01.13",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC127E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V27.01.09",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC227G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC277G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC\u00a0IPC277G PRO",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC327G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC377G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC427E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.17",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC477E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.17",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC477E PRO",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.17",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC627E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.12",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC647E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.12",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC677E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.12",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC847E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.12",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC ITP1000",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V23.01.10",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS IPC427E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.17",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-08-11T12:22:14.617Z",
              "orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
              "shortName": "siemens-SADP"
            },
            "references": [
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-306654.html"
              }
            ],
            "x_adpType": "supplier"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "An issue was discovered in Insyde InsydeH2O Kernel 5.0 before 05.08.41, Kernel 5.1 before 05.16.41, Kernel 5.2 before 05.26.41, Kernel 5.3 before 05.35.41, and Kernel 5.4 before 05.42.20. A stack-based buffer overflow leads toarbitrary code execution in UEFI DisplayTypeDxe DXE driver."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-02-22T19:06:27.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.insyde.com/security-pledge"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.insyde.com/security-pledge/SA-2022006"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://security.netapp.com/advisory/ntap-20220216-0008/"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2021-42059",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "An issue was discovered in Insyde InsydeH2O Kernel 5.0 before 05.08.41, Kernel 5.1 before 05.16.41, Kernel 5.2 before 05.26.41, Kernel 5.3 before 05.35.41, and Kernel 5.4 before 05.42.20. A stack-based buffer overflow leads toarbitrary code execution in UEFI DisplayTypeDxe DXE driver."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.insyde.com/security-pledge",
                  "refsource": "MISC",
                  "url": "https://www.insyde.com/security-pledge"
                },
                {
                  "name": "https://www.insyde.com/security-pledge/SA-2022006",
                  "refsource": "MISC",
                  "url": "https://www.insyde.com/security-pledge/SA-2022006"
                },
                {
                  "name": "https://security.netapp.com/advisory/ntap-20220216-0008/",
                  "refsource": "CONFIRM",
                  "url": "https://security.netapp.com/advisory/ntap-20220216-0008/"
                },
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf",
                  "refsource": "CONFIRM",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2021-42059",
        "datePublished": "2022-02-03T01:13:47.000Z",
        "dateReserved": "2021-10-07T00:00:00.000Z",
        "dateUpdated": "2026-08-11T12:22:14.617Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2021-41841 (GCVE-0-2021-41841)

    Vulnerability from nvd – Published: 2022-02-03 01:04 – Updated: 2026-08-11 12:22
    VLAI
    Summary
    An issue was discovered in AhciBusDxe in the kernel 5.0 through 5.5 in Insyde InsydeH2O. There is an SMM callout that allows an attacker to access the System Management Mode and execute arbitrary code. This occurs because of Inclusion of Functionality from an Untrusted Control Sphere.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Impacted products
    Vendor Product Version
    Siemens RUGGEDCOM APE1808 - BIOS Affected: 0 , < V1.0.202N (custom)
    Create a notification for this product.
    Siemens SIMATIC Field PG M5 Affected: 0 , < V22.01.10 (custom)
    Create a notification for this product.
    Siemens SIMATIC Field PG M6 Affected: 0 , < V26.01.13 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC127E Affected: 0 , < V27.01.09 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC227G Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC277G Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC277G PRO Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC327G Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC377G Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC427E Affected: 0 , < V21.01.17 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC477E Affected: 0 , < V21.01.17 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC477E PRO Affected: 0 , < V21.01.17 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC627E Affected: 0 , < V25.02.12 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC647E Affected: 0 , < V25.02.12 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC677E Affected: 0 , < V25.02.12 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC847E Affected: 0 , < V25.02.12 (custom)
    Create a notification for this product.
    Siemens SIMATIC ITP1000 Affected: 0 , < V23.01.10 (custom)
    Create a notification for this product.
    Siemens SIPLUS IPC427E Affected: 0 , < V21.01.17 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2025-11-04T19:12:38.619Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.insyde.com/security-pledge"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.insyde.com/security-pledge/SA-2022019"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://security.netapp.com/advisory/ntap-20220217-0012/"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
              },
              {
                "url": "https://www.kb.cert.org/vuls/id/796611"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "affected": [
              {
                "defaultStatus": "unknown",
                "product": "RUGGEDCOM APE1808 - BIOS",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V1.0.202N",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC Field PG M5",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V22.01.10",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC Field PG M6",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V26.01.13",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC127E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V27.01.09",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC227G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC277G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC\u00a0IPC277G PRO",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC327G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC377G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC427E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.17",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC477E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.17",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC477E PRO",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.17",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC627E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.12",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC647E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.12",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC677E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.12",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC847E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.12",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC ITP1000",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V23.01.10",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS IPC427E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.17",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-08-11T12:22:13.467Z",
              "orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
              "shortName": "siemens-SADP"
            },
            "references": [
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-306654.html"
              }
            ],
            "x_adpType": "supplier"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "An issue was discovered in AhciBusDxe in the kernel 5.0 through 5.5 in Insyde InsydeH2O. There is an SMM callout that allows an attacker to access the System Management Mode and execute arbitrary code. This occurs because of Inclusion of Functionality from an Untrusted Control Sphere."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-02-22T19:06:23.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.insyde.com/security-pledge"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.insyde.com/security-pledge/SA-2022019"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://security.netapp.com/advisory/ntap-20220217-0012/"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2021-41841",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "An issue was discovered in AhciBusDxe in the kernel 5.0 through 5.5 in Insyde InsydeH2O. There is an SMM callout that allows an attacker to access the System Management Mode and execute arbitrary code. This occurs because of Inclusion of Functionality from an Untrusted Control Sphere."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.insyde.com/security-pledge",
                  "refsource": "MISC",
                  "url": "https://www.insyde.com/security-pledge"
                },
                {
                  "name": "https://www.insyde.com/security-pledge/SA-2022019",
                  "refsource": "MISC",
                  "url": "https://www.insyde.com/security-pledge/SA-2022019"
                },
                {
                  "name": "https://security.netapp.com/advisory/ntap-20220217-0012/",
                  "refsource": "CONFIRM",
                  "url": "https://security.netapp.com/advisory/ntap-20220217-0012/"
                },
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf",
                  "refsource": "CONFIRM",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2021-41841",
        "datePublished": "2022-02-03T01:04:57.000Z",
        "dateReserved": "2021-10-01T00:00:00.000Z",
        "dateUpdated": "2026-08-11T12:22:13.467Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2021-41840 (GCVE-0-2021-41840)

    Vulnerability from nvd – Published: 2022-02-03 01:20 – Updated: 2026-08-11 12:22
    VLAI
    Summary
    An issue was discovered in NvmExpressDxe in the kernel 5.0 through 5.5 in Insyde InsydeH2O. There is an SMM callout that allows an attacker to access the System Management Mode and execute arbitrary code. This occurs because of Inclusion of Functionality from an Untrusted Control Sphere.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Impacted products
    Vendor Product Version
    Siemens SIMATIC Field PG M5 Affected: 0 , < V22.01.10 (custom)
    Create a notification for this product.
    Siemens SIMATIC Field PG M6 Affected: 0 , < V26.01.13 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC127E Affected: 0 , < V27.01.09 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC227G Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC277G Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC277G PRO Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC327G Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC377G Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC427E Affected: 0 , < V21.01.17 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC477E Affected: 0 , < V21.01.17 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC477E PRO Affected: 0 , < V21.01.17 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC627E Affected: 0 , < V25.02.12 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC647E Affected: 0 , < V25.02.12 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC677E Affected: 0 , < V25.02.12 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC847E Affected: 0 , < V25.02.12 (custom)
    Create a notification for this product.
    Siemens SIMATIC ITP1000 Affected: 0 , < V23.01.10 (custom)
    Create a notification for this product.
    Siemens SIPLUS IPC427E Affected: 0 , < V21.01.17 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2025-11-04T19:12:37.499Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.insyde.com/security-pledge"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.insyde.com/security-pledge/SA-2022018"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://security.netapp.com/advisory/ntap-20220217-0014/"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
              },
              {
                "url": "https://www.kb.cert.org/vuls/id/796611"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "affected": [
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC Field PG M5",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V22.01.10",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC Field PG M6",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V26.01.13",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC127E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V27.01.09",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC227G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC277G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC\u00a0IPC277G PRO",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC327G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC377G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC427E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.17",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC477E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.17",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC477E PRO",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.17",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC627E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.12",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC647E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.12",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC677E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.12",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC847E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.12",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC ITP1000",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V23.01.10",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS IPC427E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.17",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-08-11T12:22:12.302Z",
              "orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
              "shortName": "siemens-SADP"
            },
            "references": [
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-306654.html"
              }
            ],
            "x_adpType": "supplier"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "An issue was discovered in NvmExpressDxe in the kernel 5.0 through 5.5 in Insyde InsydeH2O. There is an SMM callout that allows an attacker to access the System Management Mode and execute arbitrary code. This occurs because of Inclusion of Functionality from an Untrusted Control Sphere."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-02-22T19:06:58.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.insyde.com/security-pledge"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.insyde.com/security-pledge/SA-2022018"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://security.netapp.com/advisory/ntap-20220217-0014/"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2021-41840",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "An issue was discovered in NvmExpressDxe in the kernel 5.0 through 5.5 in Insyde InsydeH2O. There is an SMM callout that allows an attacker to access the System Management Mode and execute arbitrary code. This occurs because of Inclusion of Functionality from an Untrusted Control Sphere."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.insyde.com/security-pledge",
                  "refsource": "MISC",
                  "url": "https://www.insyde.com/security-pledge"
                },
                {
                  "name": "https://www.insyde.com/security-pledge/SA-2022018",
                  "refsource": "MISC",
                  "url": "https://www.insyde.com/security-pledge/SA-2022018"
                },
                {
                  "name": "https://security.netapp.com/advisory/ntap-20220217-0014/",
                  "refsource": "CONFIRM",
                  "url": "https://security.netapp.com/advisory/ntap-20220217-0014/"
                },
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf",
                  "refsource": "CONFIRM",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2021-41840",
        "datePublished": "2022-02-03T01:20:07.000Z",
        "dateReserved": "2021-10-01T00:00:00.000Z",
        "dateUpdated": "2026-08-11T12:22:12.302Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2021-41839 (GCVE-0-2021-41839)

    Vulnerability from nvd – Published: 2022-02-03 01:37 – Updated: 2026-08-11 12:22
    VLAI
    Summary
    An issue was discovered in NvmExpressDxe in the kernel 5.0 through 5.5 in Insyde InsydeH2O. Because of an Untrusted Pointer Dereference that causes SMM memory corruption, an attacker may be able to write fixed or predictable data to SMRAM. Exploiting this issue could lead to escalating privileges to SMM.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Impacted products
    Vendor Product Version
    Siemens RUGGEDCOM APE1808 - BIOS Affected: 0 , < V1.0.202N (custom)
    Create a notification for this product.
    Siemens SIMATIC Field PG M5 Affected: 0 , < V22.01.10 (custom)
    Create a notification for this product.
    Siemens SIMATIC Field PG M6 Affected: 0 , < V26.01.13 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC127E Affected: 0 , < V27.01.09 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC227G Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC277G Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC277G PRO Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC327G Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC377G Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC427E Affected: 0 , < V21.01.17 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC477E Affected: 0 , < V21.01.17 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC477E PRO Affected: 0 , < V21.01.17 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC627E Affected: 0 , < V25.02.12 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC647E Affected: 0 , < V25.02.12 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC677E Affected: 0 , < V25.02.12 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC847E Affected: 0 , < V25.02.12 (custom)
    Create a notification for this product.
    Siemens SIMATIC ITP1000 Affected: 0 , < V23.01.10 (custom)
    Create a notification for this product.
    Siemens SIPLUS IPC427E Affected: 0 , < V21.01.17 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2025-11-04T19:12:36.407Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.insyde.com/security-pledge"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.insyde.com/security-pledge/SA-2022020"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://security.netapp.com/advisory/ntap-20220217-0016/"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
              },
              {
                "url": "https://www.kb.cert.org/vuls/id/796611"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "affected": [
              {
                "defaultStatus": "unknown",
                "product": "RUGGEDCOM APE1808 - BIOS",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V1.0.202N",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC Field PG M5",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V22.01.10",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC Field PG M6",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V26.01.13",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC127E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V27.01.09",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC227G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC277G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC\u00a0IPC277G PRO",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC327G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC377G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC427E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.17",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC477E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.17",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC477E PRO",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.17",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC627E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.12",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC647E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.12",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC677E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.12",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC847E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.12",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC ITP1000",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V23.01.10",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS IPC427E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.17",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-08-11T12:22:11.112Z",
              "orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
              "shortName": "siemens-SADP"
            },
            "references": [
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-306654.html"
              }
            ],
            "x_adpType": "supplier"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "An issue was discovered in NvmExpressDxe in the kernel 5.0 through 5.5 in Insyde InsydeH2O. Because of an Untrusted Pointer Dereference that causes SMM memory corruption, an attacker may be able to write fixed or predictable data to SMRAM. Exploiting this issue could lead to escalating privileges to SMM."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-02-22T19:06:25.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.insyde.com/security-pledge"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.insyde.com/security-pledge/SA-2022020"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://security.netapp.com/advisory/ntap-20220217-0016/"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2021-41839",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "An issue was discovered in NvmExpressDxe in the kernel 5.0 through 5.5 in Insyde InsydeH2O. Because of an Untrusted Pointer Dereference that causes SMM memory corruption, an attacker may be able to write fixed or predictable data to SMRAM. Exploiting this issue could lead to escalating privileges to SMM."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.insyde.com/security-pledge",
                  "refsource": "MISC",
                  "url": "https://www.insyde.com/security-pledge"
                },
                {
                  "name": "https://www.insyde.com/security-pledge/SA-2022020",
                  "refsource": "MISC",
                  "url": "https://www.insyde.com/security-pledge/SA-2022020"
                },
                {
                  "name": "https://security.netapp.com/advisory/ntap-20220217-0016/",
                  "refsource": "CONFIRM",
                  "url": "https://security.netapp.com/advisory/ntap-20220217-0016/"
                },
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf",
                  "refsource": "CONFIRM",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2021-41839",
        "datePublished": "2022-02-03T01:37:10.000Z",
        "dateReserved": "2021-10-01T00:00:00.000Z",
        "dateUpdated": "2026-08-11T12:22:11.112Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2021-41838 (GCVE-0-2021-41838)

    Vulnerability from nvd – Published: 2022-02-03 01:43 – Updated: 2026-08-11 12:22
    VLAI
    Summary
    An issue was discovered in SdHostDriver in the kernel 5.0 through 5.5 in Insyde InsydeH2O. There is an SMM callout that allows an attacker to access the System Management Mode and execute arbitrary code. This occurs because of a Numeric Range Comparison Without a Minimum Check.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Impacted products
    Vendor Product Version
    Siemens RUGGEDCOM APE1808 - BIOS Affected: 0 , < V1.0.202N (custom)
    Create a notification for this product.
    Siemens SIMATIC Field PG M5 Affected: 0 , < V22.01.10 (custom)
    Create a notification for this product.
    Siemens SIMATIC Field PG M6 Affected: 0 , < V26.01.13 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC127E Affected: 0 , < V27.01.09 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC227G Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC277G Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC277G PRO Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC327G Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC377G Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC427E Affected: 0 , < V21.01.17 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC477E Affected: 0 , < V21.01.17 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC477E PRO Affected: 0 , < V21.01.17 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC627E Affected: 0 , < V25.02.12 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC647E Affected: 0 , < V25.02.12 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC677E Affected: 0 , < V25.02.12 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC847E Affected: 0 , < V25.02.12 (custom)
    Create a notification for this product.
    Siemens SIMATIC ITP1000 Affected: 0 , < V23.01.10 (custom)
    Create a notification for this product.
    Siemens SIPLUS IPC427E Affected: 0 , < V21.01.17 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2025-11-04T19:12:35.317Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.insyde.com/security-pledge"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.insyde.com/security-pledge/SA-2022023"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://security.netapp.com/advisory/ntap-20220222-0001/"
              },
              {
                "url": "https://www.kb.cert.org/vuls/id/796611"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "affected": [
              {
                "defaultStatus": "unknown",
                "product": "RUGGEDCOM APE1808 - BIOS",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V1.0.202N",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC Field PG M5",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V22.01.10",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC Field PG M6",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V26.01.13",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC127E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V27.01.09",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC227G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC277G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC\u00a0IPC277G PRO",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC327G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC377G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC427E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.17",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC477E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.17",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC477E PRO",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.17",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC627E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.12",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC647E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.12",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC677E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.12",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC847E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.12",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC ITP1000",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V23.01.10",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS IPC427E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.17",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-08-11T12:22:09.947Z",
              "orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
              "shortName": "siemens-SADP"
            },
            "references": [
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-306654.html"
              }
            ],
            "x_adpType": "supplier"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "An issue was discovered in SdHostDriver in the kernel 5.0 through 5.5 in Insyde InsydeH2O. There is an SMM callout that allows an attacker to access the System Management Mode and execute arbitrary code. This occurs because of a Numeric Range Comparison Without a Minimum Check."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-02-23T15:06:23.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.insyde.com/security-pledge"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.insyde.com/security-pledge/SA-2022023"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://security.netapp.com/advisory/ntap-20220222-0001/"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2021-41838",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "An issue was discovered in SdHostDriver in the kernel 5.0 through 5.5 in Insyde InsydeH2O. There is an SMM callout that allows an attacker to access the System Management Mode and execute arbitrary code. This occurs because of a Numeric Range Comparison Without a Minimum Check."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.insyde.com/security-pledge",
                  "refsource": "MISC",
                  "url": "https://www.insyde.com/security-pledge"
                },
                {
                  "name": "https://www.insyde.com/security-pledge/SA-2022023",
                  "refsource": "MISC",
                  "url": "https://www.insyde.com/security-pledge/SA-2022023"
                },
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf",
                  "refsource": "CONFIRM",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
                },
                {
                  "name": "https://security.netapp.com/advisory/ntap-20220222-0001/",
                  "refsource": "CONFIRM",
                  "url": "https://security.netapp.com/advisory/ntap-20220222-0001/"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2021-41838",
        "datePublished": "2022-02-03T01:43:30.000Z",
        "dateReserved": "2021-10-01T00:00:00.000Z",
        "dateUpdated": "2026-08-11T12:22:09.947Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2021-41837 (GCVE-0-2021-41837)

    Vulnerability from nvd – Published: 2022-02-03 01:23 – Updated: 2026-08-11 12:22
    VLAI
    Summary
    An issue was discovered in AhciBusDxe in the kernel 5.0 through 5.5 in Insyde InsydeH2O. Because of an Untrusted Pointer Dereference that causes SMM memory corruption, an attacker may be able to write fixed or predictable data to SMRAM. Exploiting this issue could lead to escalating privileges to SMM.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Impacted products
    Vendor Product Version
    Siemens RUGGEDCOM APE1808 - BIOS Affected: 0 , < V1.0.202N (custom)
    Create a notification for this product.
    Siemens SIMATIC Field PG M5 Affected: 0 , < V22.01.10 (custom)
    Create a notification for this product.
    Siemens SIMATIC Field PG M6 Affected: 0 , < V26.01.13 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC127E Affected: 0 , < V27.01.09 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC227G Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC277G Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC277G PRO Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC327G Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC377G Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC427E Affected: 0 , < V21.01.17 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC477E Affected: 0 , < V21.01.17 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC477E PRO Affected: 0 , < V21.01.17 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC627E Affected: 0 , < V25.02.12 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC647E Affected: 0 , < V25.02.12 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC677E Affected: 0 , < V25.02.12 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC847E Affected: 0 , < V25.02.12 (custom)
    Create a notification for this product.
    Siemens SIMATIC ITP1000 Affected: 0 , < V23.01.10 (custom)
    Create a notification for this product.
    Siemens SIPLUS IPC427E Affected: 0 , < V21.01.17 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2025-11-04T19:12:34.238Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.insyde.com/security-pledge"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.insyde.com/security-pledge/SA-2022024"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://security.netapp.com/advisory/ntap-20220222-0003/"
              },
              {
                "url": "https://www.kb.cert.org/vuls/id/796611"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "affected": [
              {
                "defaultStatus": "unknown",
                "product": "RUGGEDCOM APE1808 - BIOS",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V1.0.202N",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC Field PG M5",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V22.01.10",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC Field PG M6",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V26.01.13",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC127E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V27.01.09",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC227G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC277G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC\u00a0IPC277G PRO",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC327G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC377G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC427E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.17",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC477E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.17",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC477E PRO",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.17",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC627E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.12",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC647E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.12",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC677E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.12",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC847E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.12",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC ITP1000",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V23.01.10",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS IPC427E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.17",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-08-11T12:22:08.782Z",
              "orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
              "shortName": "siemens-SADP"
            },
            "references": [
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-306654.html"
              }
            ],
            "x_adpType": "supplier"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "An issue was discovered in AhciBusDxe in the kernel 5.0 through 5.5 in Insyde InsydeH2O. Because of an Untrusted Pointer Dereference that causes SMM memory corruption, an attacker may be able to write fixed or predictable data to SMRAM. Exploiting this issue could lead to escalating privileges to SMM."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-02-23T15:06:18.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.insyde.com/security-pledge"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.insyde.com/security-pledge/SA-2022024"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://security.netapp.com/advisory/ntap-20220222-0003/"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2021-41837",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "An issue was discovered in AhciBusDxe in the kernel 5.0 through 5.5 in Insyde InsydeH2O. Because of an Untrusted Pointer Dereference that causes SMM memory corruption, an attacker may be able to write fixed or predictable data to SMRAM. Exploiting this issue could lead to escalating privileges to SMM."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.insyde.com/security-pledge",
                  "refsource": "MISC",
                  "url": "https://www.insyde.com/security-pledge"
                },
                {
                  "name": "https://www.insyde.com/security-pledge/SA-2022024",
                  "refsource": "MISC",
                  "url": "https://www.insyde.com/security-pledge/SA-2022024"
                },
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf",
                  "refsource": "CONFIRM",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
                },
                {
                  "name": "https://security.netapp.com/advisory/ntap-20220222-0003/",
                  "refsource": "CONFIRM",
                  "url": "https://security.netapp.com/advisory/ntap-20220222-0003/"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2021-41837",
        "datePublished": "2022-02-03T01:23:39.000Z",
        "dateReserved": "2021-10-01T00:00:00.000Z",
        "dateUpdated": "2026-08-11T12:22:08.782Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2021-33627 (GCVE-0-2021-33627)

    Vulnerability from nvd – Published: 2022-02-03 01:30 – Updated: 2026-08-11 12:22
    VLAI
    Summary
    An issue was discovered in Insyde InsydeH2O Kernel 5.0 before 05.09.11, 5.1 before 05.17.11, 5.2 before 05.27.11, 5.3 before 05.36.11, 5.4 before 05.44.11, and 5.5 before 05.52.11 affecting FwBlockServiceSmm. Software SMI services that use the Communicate() function of the EFI_SMM_COMMUNICATION_PROTOCOL do not check whether the address of the buffer is valid, which allows use of SMRAM, MMIO, or OS kernel addresses.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Impacted products
    Vendor Product Version
    Siemens RUGGEDCOM APE1808 - BIOS Affected: 0 , < V1.0.202N (custom)
    Create a notification for this product.
    Siemens SIMATIC Field PG M5 Affected: 0 , < V22.01.10 (custom)
    Create a notification for this product.
    Siemens SIMATIC Field PG M6 Affected: 0 , < V26.01.13 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC127E Affected: 0 , < V27.01.09 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC227G Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC277G Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC277G PRO Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC327G Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC377G Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC427E Affected: 0 , < V21.01.17 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC477E Affected: 0 , < V21.01.17 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC477E PRO Affected: 0 , < V21.01.17 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC627E Affected: 0 , < V25.02.12 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC647E Affected: 0 , < V25.02.12 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC677E Affected: 0 , < V25.02.12 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC847E Affected: 0 , < V25.02.12 (custom)
    Create a notification for this product.
    Siemens SIMATIC ITP1000 Affected: 0 , < V23.01.10 (custom)
    Create a notification for this product.
    Siemens SIPLUS IPC427E Affected: 0 , < V21.01.17 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2025-11-04T19:12:32.043Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.insyde.com/security-pledge"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.insyde.com/security-pledge/SA-2022022"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://security.netapp.com/advisory/ntap-20220222-0002/"
              },
              {
                "url": "https://www.kb.cert.org/vuls/id/796611"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "affected": [
              {
                "defaultStatus": "unknown",
                "product": "RUGGEDCOM APE1808 - BIOS",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V1.0.202N",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC Field PG M5",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V22.01.10",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC Field PG M6",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V26.01.13",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC127E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V27.01.09",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC227G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC277G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC\u00a0IPC277G PRO",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC327G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC377G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC427E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.17",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC477E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.17",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC477E PRO",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.17",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC627E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.12",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC647E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.12",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC677E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.12",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC847E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.12",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC ITP1000",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V23.01.10",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS IPC427E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.17",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-08-11T12:22:07.040Z",
              "orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
              "shortName": "siemens-SADP"
            },
            "references": [
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-306654.html"
              }
            ],
            "x_adpType": "supplier"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "An issue was discovered in Insyde InsydeH2O Kernel 5.0 before 05.09.11, 5.1 before 05.17.11, 5.2 before 05.27.11, 5.3 before 05.36.11, 5.4 before 05.44.11, and 5.5 before 05.52.11 affecting FwBlockServiceSmm. Software SMI services that use the Communicate() function of the EFI_SMM_COMMUNICATION_PROTOCOL do not check whether the address of the buffer is valid, which allows use of SMRAM, MMIO, or OS kernel addresses."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-07-22T16:50:10.835Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://www.insyde.com/security-pledge"
            },
            {
              "url": "https://www.insyde.com/security-pledge/SA-2022022"
            },
            {
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
            },
            {
              "url": "https://security.netapp.com/advisory/ntap-20220222-0002/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2021-33627",
        "datePublished": "2022-02-03T01:30:36.000Z",
        "dateReserved": "2021-05-28T00:00:00.000Z",
        "dateUpdated": "2026-08-11T12:22:07.040Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2021-33625 (GCVE-0-2021-33625)

    Vulnerability from nvd – Published: 2022-02-03 01:55 – Updated: 2026-08-11 12:22
    VLAI
    Summary
    An issue was discovered in Kernel 5.x in Insyde InsydeH2O, affecting HddPassword. Software SMI services that use the Communicate() function of the EFI_SMM_COMMUNICATION_PROTOCOL do not check whether the address of the buffer is valid, which allows use of SMRAM, MMIO, or OS kernel addresses.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Impacted products
    Vendor Product Version
    Siemens RUGGEDCOM APE1808 - BIOS Affected: 0 , < V1.0.202N (custom)
    Create a notification for this product.
    Siemens SIMATIC Field PG M5 Affected: 0 , < V22.01.10 (custom)
    Create a notification for this product.
    Siemens SIMATIC Field PG M6 Affected: 0 , < V26.01.13 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC127E Affected: 0 , < V27.01.09 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC227G Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC277G Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC277G PRO Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC327G Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC377G Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC427E Affected: 0 , < V21.01.17 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC477E Affected: 0 , < V21.01.17 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC477E PRO Affected: 0 , < V21.01.17 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC627E Affected: 0 , < V25.02.12 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC647E Affected: 0 , < V25.02.12 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC677E Affected: 0 , < V25.02.12 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC847E Affected: 0 , < V25.02.12 (custom)
    Create a notification for this product.
    Siemens SIMATIC ITP1000 Affected: 0 , < V23.01.10 (custom)
    Create a notification for this product.
    Siemens SIPLUS IPC427E Affected: 0 , < V21.01.17 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2025-11-04T19:12:29.871Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.insyde.com/security-pledge"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.insyde.com/security-pledge/SA-2022014"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://security.netapp.com/advisory/ntap-20220222-0004/"
              },
              {
                "url": "https://www.kb.cert.org/vuls/id/796611"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "affected": [
              {
                "defaultStatus": "unknown",
                "product": "RUGGEDCOM APE1808 - BIOS",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V1.0.202N",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC Field PG M5",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V22.01.10",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC Field PG M6",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V26.01.13",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC127E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V27.01.09",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC227G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC277G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC\u00a0IPC277G PRO",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC327G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC377G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC427E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.17",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC477E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.17",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC477E PRO",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.17",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC627E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.12",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC647E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.12",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC677E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.12",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC847E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.12",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC ITP1000",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V23.01.10",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS IPC427E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.17",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-08-11T12:22:04.521Z",
              "orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
              "shortName": "siemens-SADP"
            },
            "references": [
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-306654.html"
              }
            ],
            "x_adpType": "supplier"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "An issue was discovered in Kernel 5.x in Insyde InsydeH2O, affecting HddPassword. Software SMI services that use the Communicate() function of the EFI_SMM_COMMUNICATION_PROTOCOL do not check whether the address of the buffer is valid, which allows use of SMRAM, MMIO, or OS kernel addresses."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-02-23T15:06:25.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.insyde.com/security-pledge"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.insyde.com/security-pledge/SA-2022014"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://security.netapp.com/advisory/ntap-20220222-0004/"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2021-33625",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "An issue was discovered in Kernel 5.x in Insyde InsydeH2O, affecting HddPassword. Software SMI services that use the Communicate() function of the EFI_SMM_COMMUNICATION_PROTOCOL do not check whether the address of the buffer is valid, which allows use of SMRAM, MMIO, or OS kernel addresses."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.insyde.com/security-pledge",
                  "refsource": "MISC",
                  "url": "https://www.insyde.com/security-pledge"
                },
                {
                  "name": "https://www.insyde.com/security-pledge/SA-2022014",
                  "refsource": "MISC",
                  "url": "https://www.insyde.com/security-pledge/SA-2022014"
                },
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf",
                  "refsource": "CONFIRM",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
                },
                {
                  "name": "https://security.netapp.com/advisory/ntap-20220222-0004/",
                  "refsource": "CONFIRM",
                  "url": "https://security.netapp.com/advisory/ntap-20220222-0004/"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2021-33625",
        "datePublished": "2022-02-03T01:55:10.000Z",
        "dateReserved": "2021-05-28T00:00:00.000Z",
        "dateUpdated": "2026-08-11T12:22:04.521Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-2884 (GCVE-0-2025-2884)

    Vulnerability from cvelistv5 – Published: 2025-06-10 17:29 – Updated: 2026-08-11 12:22
    VLAI
    Title
    Out-of-Bounds read vulnerability in TCG TPM2.0 reference implementation
    Summary
    TCG TPM2.0 Reference implementation's CryptHmacSign helper function is vulnerable to Out-of-Bounds read due to the lack of validation the signature scheme with the signature key's algorithm. See Errata Revision 1.83 and advisory TCGVRT0009 for TCG standard TPM2.0
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial Mission & Well-being: medium
    certcc
    Decision recorded 2025-06-13 17:22 UTC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-06-13 01:41 UTC
    CWE
    Impacted products
    Vendor Product Version
    Trusted Computing Group TPM2.0 Affected: 0 , < 1.83 (custom)
    Create a notification for this product.
    Siemens SIMATIC CN 4100 Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SIMATIC Field PG M5 Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SIMATIC Field PG M6 Affected: 0 , < V26.01.14 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC BX-32A Affected: 0 , < V29.01.09 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC BX-39A Affected: 0 , < V29.01.09 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC BX-56A Affected: 0 , < V32.01.09 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC BX-59A Affected: 0 , < V32.01.09 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC MD-57A Affected: 0 , < V30.01.10 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC PX-32A Affected: 0 , < V29.01.09 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC PX-39A Affected: 0 , < V29.01.09 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC PX-39A PRO Affected: 0 , < V29.01.09 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC RW-528A Affected: 0 , < V34.01.02 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC RW-548A Affected: 0 , < V34.01.02 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC227E Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC277E Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC427E Affected: 0 , < V21.01.20 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC477E Affected: 0 , < V21.01.20 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC477E PRO Affected: 0 , < V21.01.20 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC627E Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC647E Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC677E Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC847E Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SIMATIC ITP1000 Affected: 0 , < * (custom)
    Create a notification for this product.
    Siemens SIPLUS IPC427E Affected: 0 , < V21.01.20 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2025-06-10T19:02:29.811Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-01209.html"
              },
              {
                "url": "https://www.kb.cert.org/vuls/id/282450"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "LOCAL",
                  "availabilityImpact": "HIGH",
                  "baseScore": 6.6,
                  "baseSeverity": "MEDIUM",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "NONE",
                  "privilegesRequired": "LOW",
                  "scope": "UNCHANGED",
                  "userInteraction": "REQUIRED",
                  "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:N/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-2884",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-06-13T01:41:10.489446Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-125",
                    "description": "CWE-125 Out-of-bounds Read",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-06-13T01:46:13.802Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "affected": [
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC CN 4100",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC Field PG M5",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC Field PG M6",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V26.01.14",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC BX-32A",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V29.01.09",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC BX-39A",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V29.01.09",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC BX-56A",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V32.01.09",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC BX-59A",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V32.01.09",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC MD-57A",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V30.01.10",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC PX-32A",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V29.01.09",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC PX-39A",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V29.01.09",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC PX-39A PRO",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V29.01.09",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC RW-528A",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V34.01.02",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC RW-548A",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V34.01.02",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC227E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC277E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC427E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.20",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC477E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.20",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC477E PRO",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.20",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC627E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC647E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC677E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC847E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC ITP1000",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS IPC427E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.20",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-08-11T12:22:36.753Z",
              "orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
              "shortName": "siemens-SADP"
            },
            "references": [
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-628843.html"
              }
            ],
            "x_adpType": "supplier"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "TPM2.0",
              "vendor": "Trusted Computing Group",
              "versions": [
                {
                  "lessThan": "1.83",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "TCG TPM2.0 Reference implementation\u0027s CryptHmacSign helper function is vulnerable to Out-of-Bounds read due to the lack of validation the signature scheme with the signature key\u0027s algorithm. See Errata Revision 1.83 and advisory TCGVRT0009 for TCG standard TPM2.0"
            }
          ],
          "metrics": [
            {
              "other": {
                "content": {
                  "id": "CVE-2025-2884",
                  "selections": [
                    {
                      "name": "Exploitation",
                      "namespace": "ssvc",
                      "values": [
                        "none"
                      ],
                      "version": "1.0.0"
                    },
                    {
                      "name": "Automatable",
                      "namespace": "ssvc",
                      "values": [
                        "no"
                      ],
                      "version": "2.0.0"
                    },
                    {
                      "name": "Technical Impact",
                      "namespace": "ssvc",
                      "values": [
                        "partial"
                      ],
                      "version": "1.0.0"
                    },
                    {
                      "name": "Mission \u0026 Well-being",
                      "namespace": "ssvc",
                      "values": [
                        "medium"
                      ],
                      "version": "1.0.0"
                    }
                  ],
                  "timestamp": "2025-06-13T17:22:30.584Z"
                },
                "type": "ssvcV1_0_1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "CWE-125 Out-of-bounds Read",
                  "lang": "en"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-06-13T18:22:21.856Z",
            "orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
            "shortName": "certcc"
          },
          "references": [
            {
              "url": "https://trustedcomputinggroup.org/about/security/"
            },
            {
              "name": "TPM2.0 Errata",
              "url": "https://trustedcomputinggroup.org/wp-content/uploads/TPM2.0-Library-Spec-v1.83-Errata_v1_pub.pdf"
            },
            {
              "name": "Vendor Advisory",
              "url": "https://trustedcomputinggroup.org/wp-content/uploads/VRT0009-Advisory-FINAL.pdf"
            },
            {
              "name": "Vendor Patch",
              "url": "https://github.com/stefanberger/libtpms/commit/04b2d8e9afc0a9b6bffe562a23e58c0de11532d1"
            },
            {
              "name": "Related CVE",
              "url": "https://www.cve.org/CVERecord?id=CVE-2025-49133"
            }
          ],
          "source": {
            "discovery": "INTERNAL"
          },
          "title": "Out-of-Bounds read vulnerability in TCG TPM2.0 reference implementation",
          "x_generator": {
            "engine": "VINCE 3.0.20",
            "env": "prod",
            "origin": "https://cveawg.mitre.org/api/cve/CVE-2025-2884"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
        "assignerShortName": "certcc",
        "cveId": "CVE-2025-2884",
        "datePublished": "2025-06-10T17:29:19.463Z",
        "dateReserved": "2025-03-27T21:01:41.908Z",
        "dateUpdated": "2026-08-11T12:22:36.753Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2022-21198 (GCVE-0-2022-21198)

    Vulnerability from cvelistv5 – Published: 2022-11-11 15:49 – Updated: 2026-08-11 12:22
    VLAI
    Summary
    Time-of-check time-of-use race condition in the BIOS firmware for some Intel(R) Processors may allow a privileged user to potentially enable escalation of privilege via local access.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-01-29 20:38 UTC
    CWE
    • escalation of privilege
    • CWE-367 - Time-of-check Time-of-use (TOCTOU) Race Condition
    Impacted products
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T02:31:59.787Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00688.html",
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00688.html"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-21198",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-01-29T20:38:21.227981Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-367",
                    "description": "CWE-367 Time-of-check Time-of-use (TOCTOU) Race Condition",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-02-04T17:58:34.848Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "affected": [
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC Field PG M5",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V22.01.11",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC Field PG M6",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V26.01.11",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC BX-39A",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V29.01.03",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC PX-39A",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V29.01.03",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC PX-39A PRO",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V29.01.03",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC427E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.19",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC477E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.19",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC477E PRO",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.19",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC627E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.14",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC647E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.14",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC677E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.14",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC847E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.14",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC ITP1000",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS IPC427E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.19",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-08-11T12:22:27.669Z",
              "orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
              "shortName": "siemens-SADP"
            },
            "references": [
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-686975.html"
              }
            ],
            "x_adpType": "supplier"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Intel(R) Processors",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "See references"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Time-of-check time-of-use race condition in the BIOS firmware for some Intel(R) Processors may allow a privileged user to potentially enable escalation of privilege via local access."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 7.9,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:N/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "escalation of privilege",
                  "lang": "en"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-11-14T17:46:28.257Z",
            "orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
            "shortName": "intel"
          },
          "references": [
            {
              "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00688.html",
              "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00688.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
        "assignerShortName": "intel",
        "cveId": "CVE-2022-21198",
        "datePublished": "2022-11-11T15:49:10.831Z",
        "dateReserved": "2022-02-18T21:23:59.775Z",
        "dateUpdated": "2026-08-11T12:22:27.669Z",
        "requesterUserId": "524a9a6b-3515-4b97-ab85-1a9a79493852",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2022-24031 (GCVE-0-2022-24031)

    Vulnerability from cvelistv5 – Published: 2022-02-03 01:59 – Updated: 2026-08-11 12:22
    VLAI
    Summary
    An issue was discovered in NvmExpressDxe in Insyde InsydeH2O with kernel 5.1 through 5.5. An SMM memory corruption vulnerability allows an attacker to write fixed or predictable data to SMRAM. Exploiting this issue could lead to escalating privileges to SMM.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Impacted products
    Vendor Product Version
    Siemens RUGGEDCOM APE1808 - BIOS Affected: 0 , < V1.0.202N (custom)
    Create a notification for this product.
    Siemens SIMATIC Field PG M5 Affected: 0 , < V22.01.10 (custom)
    Create a notification for this product.
    Siemens SIMATIC Field PG M6 Affected: 0 , < V26.01.13 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC127E Affected: 0 , < V27.01.09 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC227G Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC277G Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC277G PRO Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC327G Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC377G Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC427E Affected: 0 , < V21.01.17 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC477E Affected: 0 , < V21.01.17 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC477E PRO Affected: 0 , < V21.01.17 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC627E Affected: 0 , < V25.02.12 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC647E Affected: 0 , < V25.02.12 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC677E Affected: 0 , < V25.02.12 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC847E Affected: 0 , < V25.02.12 (custom)
    Create a notification for this product.
    Siemens SIMATIC ITP1000 Affected: 0 , < V23.01.10 (custom)
    Create a notification for this product.
    Siemens SIPLUS IPC427E Affected: 0 , < V21.01.17 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2025-11-04T19:12:59.895Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.insyde.com/security-pledge"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.insyde.com/security-pledge/SA-2022015"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://security.netapp.com/advisory/ntap-20220216-0009/"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
              },
              {
                "url": "https://www.kb.cert.org/vuls/id/796611"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "affected": [
              {
                "defaultStatus": "unknown",
                "product": "RUGGEDCOM APE1808 - BIOS",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V1.0.202N",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC Field PG M5",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V22.01.10",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC Field PG M6",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V26.01.13",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC127E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V27.01.09",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC227G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC277G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC\u00a0IPC277G PRO",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC327G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC377G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC427E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.17",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC477E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.17",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC477E PRO",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.17",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC627E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.12",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC647E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.12",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC677E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.12",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC847E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.12",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC ITP1000",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V23.01.10",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS IPC427E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.17",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-08-11T12:22:29.973Z",
              "orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
              "shortName": "siemens-SADP"
            },
            "references": [
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-306654.html"
              }
            ],
            "x_adpType": "supplier"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "An issue was discovered in NvmExpressDxe in Insyde InsydeH2O with kernel 5.1 through 5.5. An SMM memory corruption vulnerability allows an attacker to write fixed or predictable data to SMRAM. Exploiting this issue could lead to escalating privileges to SMM."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-02-22T19:06:47.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.insyde.com/security-pledge"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.insyde.com/security-pledge/SA-2022015"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://security.netapp.com/advisory/ntap-20220216-0009/"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2022-24031",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "An issue was discovered in NvmExpressDxe in Insyde InsydeH2O with kernel 5.1 through 5.5. An SMM memory corruption vulnerability allows an attacker to write fixed or predictable data to SMRAM. Exploiting this issue could lead to escalating privileges to SMM."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.insyde.com/security-pledge",
                  "refsource": "MISC",
                  "url": "https://www.insyde.com/security-pledge"
                },
                {
                  "name": "https://www.insyde.com/security-pledge/SA-2022015",
                  "refsource": "MISC",
                  "url": "https://www.insyde.com/security-pledge/SA-2022015"
                },
                {
                  "name": "https://security.netapp.com/advisory/ntap-20220216-0009/",
                  "refsource": "CONFIRM",
                  "url": "https://security.netapp.com/advisory/ntap-20220216-0009/"
                },
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf",
                  "refsource": "CONFIRM",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2022-24031",
        "datePublished": "2022-02-03T01:59:49.000Z",
        "dateReserved": "2022-01-26T00:00:00.000Z",
        "dateUpdated": "2026-08-11T12:22:29.973Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2021-33625 (GCVE-0-2021-33625)

    Vulnerability from cvelistv5 – Published: 2022-02-03 01:55 – Updated: 2026-08-11 12:22
    VLAI
    Summary
    An issue was discovered in Kernel 5.x in Insyde InsydeH2O, affecting HddPassword. Software SMI services that use the Communicate() function of the EFI_SMM_COMMUNICATION_PROTOCOL do not check whether the address of the buffer is valid, which allows use of SMRAM, MMIO, or OS kernel addresses.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Impacted products
    Vendor Product Version
    Siemens RUGGEDCOM APE1808 - BIOS Affected: 0 , < V1.0.202N (custom)
    Create a notification for this product.
    Siemens SIMATIC Field PG M5 Affected: 0 , < V22.01.10 (custom)
    Create a notification for this product.
    Siemens SIMATIC Field PG M6 Affected: 0 , < V26.01.13 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC127E Affected: 0 , < V27.01.09 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC227G Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC277G Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC277G PRO Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC327G Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC377G Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC427E Affected: 0 , < V21.01.17 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC477E Affected: 0 , < V21.01.17 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC477E PRO Affected: 0 , < V21.01.17 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC627E Affected: 0 , < V25.02.12 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC647E Affected: 0 , < V25.02.12 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC677E Affected: 0 , < V25.02.12 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC847E Affected: 0 , < V25.02.12 (custom)
    Create a notification for this product.
    Siemens SIMATIC ITP1000 Affected: 0 , < V23.01.10 (custom)
    Create a notification for this product.
    Siemens SIPLUS IPC427E Affected: 0 , < V21.01.17 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2025-11-04T19:12:29.871Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.insyde.com/security-pledge"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.insyde.com/security-pledge/SA-2022014"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://security.netapp.com/advisory/ntap-20220222-0004/"
              },
              {
                "url": "https://www.kb.cert.org/vuls/id/796611"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "affected": [
              {
                "defaultStatus": "unknown",
                "product": "RUGGEDCOM APE1808 - BIOS",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V1.0.202N",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC Field PG M5",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V22.01.10",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC Field PG M6",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V26.01.13",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC127E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V27.01.09",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC227G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC277G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC\u00a0IPC277G PRO",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC327G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC377G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC427E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.17",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC477E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.17",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC477E PRO",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.17",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC627E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.12",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC647E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.12",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC677E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.12",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC847E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.12",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC ITP1000",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V23.01.10",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS IPC427E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.17",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-08-11T12:22:04.521Z",
              "orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
              "shortName": "siemens-SADP"
            },
            "references": [
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-306654.html"
              }
            ],
            "x_adpType": "supplier"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "An issue was discovered in Kernel 5.x in Insyde InsydeH2O, affecting HddPassword. Software SMI services that use the Communicate() function of the EFI_SMM_COMMUNICATION_PROTOCOL do not check whether the address of the buffer is valid, which allows use of SMRAM, MMIO, or OS kernel addresses."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-02-23T15:06:25.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.insyde.com/security-pledge"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.insyde.com/security-pledge/SA-2022014"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://security.netapp.com/advisory/ntap-20220222-0004/"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2021-33625",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "An issue was discovered in Kernel 5.x in Insyde InsydeH2O, affecting HddPassword. Software SMI services that use the Communicate() function of the EFI_SMM_COMMUNICATION_PROTOCOL do not check whether the address of the buffer is valid, which allows use of SMRAM, MMIO, or OS kernel addresses."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.insyde.com/security-pledge",
                  "refsource": "MISC",
                  "url": "https://www.insyde.com/security-pledge"
                },
                {
                  "name": "https://www.insyde.com/security-pledge/SA-2022014",
                  "refsource": "MISC",
                  "url": "https://www.insyde.com/security-pledge/SA-2022014"
                },
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf",
                  "refsource": "CONFIRM",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
                },
                {
                  "name": "https://security.netapp.com/advisory/ntap-20220222-0004/",
                  "refsource": "CONFIRM",
                  "url": "https://security.netapp.com/advisory/ntap-20220222-0004/"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2021-33625",
        "datePublished": "2022-02-03T01:55:10.000Z",
        "dateReserved": "2021-05-28T00:00:00.000Z",
        "dateUpdated": "2026-08-11T12:22:04.521Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2021-43323 (GCVE-0-2021-43323)

    Vulnerability from cvelistv5 – Published: 2022-02-03 01:50 – Updated: 2026-08-11 12:22
    VLAI
    Summary
    An issue was discovered in UsbCoreDxe in Insyde InsydeH2O with kernel 5.5 before 05.51.45, 5.4 before 05.43.45, 5.3 before 05.35.45, 5.2 before 05.26.45, 5.1 before 05.16.45, and 5.0 before 05.08.45. An SMM callout vulnerability allows an attacker to hijack execution flow of code running in System Management Mode. Exploiting this issue could lead to escalating privileges to SMM.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Impacted products
    Vendor Product Version
    Siemens RUGGEDCOM APE1808 - BIOS Affected: 0 , < V1.0.202N (custom)
    Create a notification for this product.
    Siemens SIMATIC Field PG M5 Affected: 0 , < V22.01.10 (custom)
    Create a notification for this product.
    Siemens SIMATIC Field PG M6 Affected: 0 , < V26.01.13 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC127E Affected: 0 , < V27.01.09 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC227G Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC277G Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC277G PRO Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC327G Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC377G Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC427E Affected: 0 , < V21.01.17 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC477E Affected: 0 , < V21.01.17 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC477E PRO Affected: 0 , < V21.01.17 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC627E Affected: 0 , < V25.02.12 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC647E Affected: 0 , < V25.02.12 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC677E Affected: 0 , < V25.02.12 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC847E Affected: 0 , < V25.02.12 (custom)
    Create a notification for this product.
    Siemens SIMATIC ITP1000 Affected: 0 , < V23.01.10 (custom)
    Create a notification for this product.
    Siemens SIPLUS IPC427E Affected: 0 , < V21.01.17 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2025-11-04T19:12:44.192Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.insyde.com/security-pledge"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://security.netapp.com/advisory/ntap-20220217-0013/"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
              },
              {
                "url": "https://www.kb.cert.org/vuls/id/796611"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "affected": [
              {
                "defaultStatus": "unknown",
                "product": "RUGGEDCOM APE1808 - BIOS",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V1.0.202N",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC Field PG M5",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V22.01.10",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC Field PG M6",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V26.01.13",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC127E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V27.01.09",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC227G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC277G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC\u00a0IPC277G PRO",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC327G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC377G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC427E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.17",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC477E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.17",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC477E PRO",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.17",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC627E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.12",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC647E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.12",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC677E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.12",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC847E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.12",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC ITP1000",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V23.01.10",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS IPC427E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.17",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-08-11T12:22:19.420Z",
              "orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
              "shortName": "siemens-SADP"
            },
            "references": [
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-306654.html"
              }
            ],
            "x_adpType": "supplier"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "An issue was discovered in UsbCoreDxe in Insyde InsydeH2O with kernel 5.5 before 05.51.45, 5.4 before 05.43.45, 5.3 before 05.35.45, 5.2 before 05.26.45, 5.1 before 05.16.45, and 5.0 before 05.08.45. An SMM callout vulnerability allows an attacker to hijack execution flow of code running in System Management Mode. Exploiting this issue could lead to escalating privileges to SMM."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-02-22T19:06:29.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.insyde.com/security-pledge"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://security.netapp.com/advisory/ntap-20220217-0013/"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2021-43323",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "An issue was discovered in UsbCoreDxe in Insyde InsydeH2O with kernel 5.5 before 05.51.45, 5.4 before 05.43.45, 5.3 before 05.35.45, 5.2 before 05.26.45, 5.1 before 05.16.45, and 5.0 before 05.08.45. An SMM callout vulnerability allows an attacker to hijack execution flow of code running in System Management Mode. Exploiting this issue could lead to escalating privileges to SMM."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.insyde.com/security-pledge",
                  "refsource": "MISC",
                  "url": "https://www.insyde.com/security-pledge"
                },
                {
                  "name": "https://security.netapp.com/advisory/ntap-20220217-0013/",
                  "refsource": "CONFIRM",
                  "url": "https://security.netapp.com/advisory/ntap-20220217-0013/"
                },
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf",
                  "refsource": "CONFIRM",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2021-43323",
        "datePublished": "2022-02-03T01:50:01.000Z",
        "dateReserved": "2021-11-03T00:00:00.000Z",
        "dateUpdated": "2026-08-11T12:22:19.420Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2021-42113 (GCVE-0-2021-42113)

    Vulnerability from cvelistv5 – Published: 2022-02-03 01:46 – Updated: 2026-08-11 12:22
    VLAI
    Summary
    An issue was discovered in StorageSecurityCommandDxe in Insyde InsydeH2O with Kernel 5.1 before 05.14.28, Kernel 5.2 before 05.24.28, and Kernel 5.3 before 05.32.25. An SMM callout vulnerability allows an attacker to hijack execution flow of code running in System Management Mode. Exploiting this issue could lead to escalating privileges to SMM.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Impacted products
    Vendor Product Version
    Siemens RUGGEDCOM APE1808 - BIOS Affected: 0 , < V1.0.202N (custom)
    Create a notification for this product.
    Siemens SIMATIC Field PG M5 Affected: 0 , < V22.01.10 (custom)
    Create a notification for this product.
    Siemens SIMATIC Field PG M6 Affected: 0 , < V26.01.13 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC127E Affected: 0 , < V27.01.09 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC227G Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC277G Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC277G PRO Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC327G Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC377G Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC427E Affected: 0 , < V21.01.17 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC477E Affected: 0 , < V21.01.17 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC477E PRO Affected: 0 , < V21.01.17 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC627E Affected: 0 , < V25.02.12 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC647E Affected: 0 , < V25.02.12 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC677E Affected: 0 , < V25.02.12 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC847E Affected: 0 , < V25.02.12 (custom)
    Create a notification for this product.
    Siemens SIMATIC ITP1000 Affected: 0 , < V23.01.10 (custom)
    Create a notification for this product.
    Siemens SIPLUS IPC427E Affected: 0 , < V21.01.17 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2025-11-04T19:12:42.015Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.insyde.com/security-pledge"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.insyde.com/security-pledge/SA-2022008"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://security.netapp.com/advisory/ntap-20220216-0012/"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
              },
              {
                "url": "https://www.kb.cert.org/vuls/id/796611"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "affected": [
              {
                "defaultStatus": "unknown",
                "product": "RUGGEDCOM APE1808 - BIOS",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V1.0.202N",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC Field PG M5",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V22.01.10",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC Field PG M6",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V26.01.13",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC127E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V27.01.09",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC227G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC277G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC\u00a0IPC277G PRO",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC327G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC377G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC427E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.17",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC477E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.17",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC477E PRO",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.17",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC627E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.12",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC647E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.12",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC677E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.12",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC847E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.12",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC ITP1000",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V23.01.10",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS IPC427E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.17",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-08-11T12:22:17.067Z",
              "orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
              "shortName": "siemens-SADP"
            },
            "references": [
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-306654.html"
              }
            ],
            "x_adpType": "supplier"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "An issue was discovered in StorageSecurityCommandDxe in Insyde InsydeH2O with Kernel 5.1 before 05.14.28, Kernel 5.2 before 05.24.28, and Kernel 5.3 before 05.32.25. An SMM callout vulnerability allows an attacker to hijack execution flow of code running in System Management Mode. Exploiting this issue could lead to escalating privileges to SMM."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-02-22T19:06:49.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.insyde.com/security-pledge"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.insyde.com/security-pledge/SA-2022008"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://security.netapp.com/advisory/ntap-20220216-0012/"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2021-42113",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "An issue was discovered in StorageSecurityCommandDxe in Insyde InsydeH2O with Kernel 5.1 before 05.14.28, Kernel 5.2 before 05.24.28, and Kernel 5.3 before 05.32.25. An SMM callout vulnerability allows an attacker to hijack execution flow of code running in System Management Mode. Exploiting this issue could lead to escalating privileges to SMM."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.insyde.com/security-pledge",
                  "refsource": "MISC",
                  "url": "https://www.insyde.com/security-pledge"
                },
                {
                  "name": "https://www.insyde.com/security-pledge/SA-2022008",
                  "refsource": "MISC",
                  "url": "https://www.insyde.com/security-pledge/SA-2022008"
                },
                {
                  "name": "https://security.netapp.com/advisory/ntap-20220216-0012/",
                  "refsource": "CONFIRM",
                  "url": "https://security.netapp.com/advisory/ntap-20220216-0012/"
                },
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf",
                  "refsource": "CONFIRM",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2021-42113",
        "datePublished": "2022-02-03T01:46:08.000Z",
        "dateReserved": "2021-10-08T00:00:00.000Z",
        "dateUpdated": "2026-08-11T12:22:17.067Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2021-41838 (GCVE-0-2021-41838)

    Vulnerability from cvelistv5 – Published: 2022-02-03 01:43 – Updated: 2026-08-11 12:22
    VLAI
    Summary
    An issue was discovered in SdHostDriver in the kernel 5.0 through 5.5 in Insyde InsydeH2O. There is an SMM callout that allows an attacker to access the System Management Mode and execute arbitrary code. This occurs because of a Numeric Range Comparison Without a Minimum Check.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Impacted products
    Vendor Product Version
    Siemens RUGGEDCOM APE1808 - BIOS Affected: 0 , < V1.0.202N (custom)
    Create a notification for this product.
    Siemens SIMATIC Field PG M5 Affected: 0 , < V22.01.10 (custom)
    Create a notification for this product.
    Siemens SIMATIC Field PG M6 Affected: 0 , < V26.01.13 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC127E Affected: 0 , < V27.01.09 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC227G Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC277G Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC277G PRO Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC327G Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC377G Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC427E Affected: 0 , < V21.01.17 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC477E Affected: 0 , < V21.01.17 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC477E PRO Affected: 0 , < V21.01.17 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC627E Affected: 0 , < V25.02.12 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC647E Affected: 0 , < V25.02.12 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC677E Affected: 0 , < V25.02.12 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC847E Affected: 0 , < V25.02.12 (custom)
    Create a notification for this product.
    Siemens SIMATIC ITP1000 Affected: 0 , < V23.01.10 (custom)
    Create a notification for this product.
    Siemens SIPLUS IPC427E Affected: 0 , < V21.01.17 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2025-11-04T19:12:35.317Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.insyde.com/security-pledge"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.insyde.com/security-pledge/SA-2022023"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://security.netapp.com/advisory/ntap-20220222-0001/"
              },
              {
                "url": "https://www.kb.cert.org/vuls/id/796611"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "affected": [
              {
                "defaultStatus": "unknown",
                "product": "RUGGEDCOM APE1808 - BIOS",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V1.0.202N",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC Field PG M5",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V22.01.10",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC Field PG M6",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V26.01.13",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC127E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V27.01.09",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC227G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC277G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC\u00a0IPC277G PRO",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC327G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC377G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC427E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.17",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC477E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.17",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC477E PRO",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.17",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC627E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.12",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC647E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.12",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC677E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.12",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC847E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.12",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC ITP1000",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V23.01.10",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS IPC427E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.17",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-08-11T12:22:09.947Z",
              "orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
              "shortName": "siemens-SADP"
            },
            "references": [
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-306654.html"
              }
            ],
            "x_adpType": "supplier"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "An issue was discovered in SdHostDriver in the kernel 5.0 through 5.5 in Insyde InsydeH2O. There is an SMM callout that allows an attacker to access the System Management Mode and execute arbitrary code. This occurs because of a Numeric Range Comparison Without a Minimum Check."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-02-23T15:06:23.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.insyde.com/security-pledge"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.insyde.com/security-pledge/SA-2022023"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://security.netapp.com/advisory/ntap-20220222-0001/"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2021-41838",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "An issue was discovered in SdHostDriver in the kernel 5.0 through 5.5 in Insyde InsydeH2O. There is an SMM callout that allows an attacker to access the System Management Mode and execute arbitrary code. This occurs because of a Numeric Range Comparison Without a Minimum Check."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.insyde.com/security-pledge",
                  "refsource": "MISC",
                  "url": "https://www.insyde.com/security-pledge"
                },
                {
                  "name": "https://www.insyde.com/security-pledge/SA-2022023",
                  "refsource": "MISC",
                  "url": "https://www.insyde.com/security-pledge/SA-2022023"
                },
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf",
                  "refsource": "CONFIRM",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
                },
                {
                  "name": "https://security.netapp.com/advisory/ntap-20220222-0001/",
                  "refsource": "CONFIRM",
                  "url": "https://security.netapp.com/advisory/ntap-20220222-0001/"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2021-41838",
        "datePublished": "2022-02-03T01:43:30.000Z",
        "dateReserved": "2021-10-01T00:00:00.000Z",
        "dateUpdated": "2026-08-11T12:22:09.947Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2021-42554 (GCVE-0-2021-42554)

    Vulnerability from cvelistv5 – Published: 2022-02-03 01:40 – Updated: 2026-08-11 12:22
    VLAI
    Summary
    An issue was discovered in Insyde InsydeH2O with Kernel 5.0 before 05.08.42, Kernel 5.1 before 05.16.42, Kernel 5.2 before 05.26.42, Kernel 5.3 before 05.35.42, Kernel 5.4 before 05.42.51, and Kernel 5.5 before 05.50.51. An SMM memory corruption vulnerability in FvbServicesRuntimeDxe allows a possible attacker to write fixed or predictable data to SMRAM. Exploiting this issue could lead to escalating privileges to SMM.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Impacted products
    Vendor Product Version
    Siemens RUGGEDCOM APE1808 - BIOS Affected: 0 , < V1.0.202N (custom)
    Create a notification for this product.
    Siemens SIMATIC Field PG M5 Affected: 0 , < V22.01.10 (custom)
    Create a notification for this product.
    Siemens SIMATIC Field PG M6 Affected: 0 , < V26.01.13 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC127E Affected: 0 , < V27.01.09 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC227G Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC277G Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC277G PRO Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC327G Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC377G Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC427E Affected: 0 , < V21.01.17 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC477E Affected: 0 , < V21.01.17 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC477E PRO Affected: 0 , < V21.01.17 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC627E Affected: 0 , < V25.02.12 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC647E Affected: 0 , < V25.02.12 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC677E Affected: 0 , < V25.02.12 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC847E Affected: 0 , < V25.02.12 (custom)
    Create a notification for this product.
    Siemens SIMATIC ITP1000 Affected: 0 , < V23.01.10 (custom)
    Create a notification for this product.
    Siemens SIPLUS IPC427E Affected: 0 , < V21.01.17 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2025-11-04T19:12:43.116Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.insyde.com/security-pledge"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.insyde.com/security-pledge/SA-2022012"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://security.netapp.com/advisory/ntap-20220216-0007/"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
              },
              {
                "url": "https://www.kb.cert.org/vuls/id/796611"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "affected": [
              {
                "defaultStatus": "unknown",
                "product": "RUGGEDCOM APE1808 - BIOS",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V1.0.202N",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC Field PG M5",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V22.01.10",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC Field PG M6",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V26.01.13",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC127E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V27.01.09",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC227G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC277G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC\u00a0IPC277G PRO",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC327G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC377G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC427E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.17",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC477E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.17",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC477E PRO",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.17",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC627E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.12",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC647E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.12",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC677E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.12",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC847E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.12",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC ITP1000",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V23.01.10",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS IPC427E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.17",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-08-11T12:22:18.229Z",
              "orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
              "shortName": "siemens-SADP"
            },
            "references": [
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-306654.html"
              }
            ],
            "x_adpType": "supplier"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "An issue was discovered in Insyde InsydeH2O with Kernel 5.0 before 05.08.42, Kernel 5.1 before 05.16.42, Kernel 5.2 before 05.26.42, Kernel 5.3 before 05.35.42, Kernel 5.4 before 05.42.51, and Kernel 5.5 before 05.50.51. An SMM memory corruption vulnerability in FvbServicesRuntimeDxe allows a possible attacker to write fixed or predictable data to SMRAM. Exploiting this issue could lead to escalating privileges to SMM."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-02-22T19:06:40.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.insyde.com/security-pledge"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.insyde.com/security-pledge/SA-2022012"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://security.netapp.com/advisory/ntap-20220216-0007/"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2021-42554",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "An issue was discovered in Insyde InsydeH2O with Kernel 5.0 before 05.08.42, Kernel 5.1 before 05.16.42, Kernel 5.2 before 05.26.42, Kernel 5.3 before 05.35.42, Kernel 5.4 before 05.42.51, and Kernel 5.5 before 05.50.51. An SMM memory corruption vulnerability in FvbServicesRuntimeDxe allows a possible attacker to write fixed or predictable data to SMRAM. Exploiting this issue could lead to escalating privileges to SMM."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.insyde.com/security-pledge",
                  "refsource": "MISC",
                  "url": "https://www.insyde.com/security-pledge"
                },
                {
                  "name": "https://www.insyde.com/security-pledge/SA-2022012",
                  "refsource": "MISC",
                  "url": "https://www.insyde.com/security-pledge/SA-2022012"
                },
                {
                  "name": "https://security.netapp.com/advisory/ntap-20220216-0007/",
                  "refsource": "CONFIRM",
                  "url": "https://security.netapp.com/advisory/ntap-20220216-0007/"
                },
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf",
                  "refsource": "CONFIRM",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2021-42554",
        "datePublished": "2022-02-03T01:40:56.000Z",
        "dateReserved": "2021-10-18T00:00:00.000Z",
        "dateUpdated": "2026-08-11T12:22:18.229Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2021-41839 (GCVE-0-2021-41839)

    Vulnerability from cvelistv5 – Published: 2022-02-03 01:37 – Updated: 2026-08-11 12:22
    VLAI
    Summary
    An issue was discovered in NvmExpressDxe in the kernel 5.0 through 5.5 in Insyde InsydeH2O. Because of an Untrusted Pointer Dereference that causes SMM memory corruption, an attacker may be able to write fixed or predictable data to SMRAM. Exploiting this issue could lead to escalating privileges to SMM.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Impacted products
    Vendor Product Version
    Siemens RUGGEDCOM APE1808 - BIOS Affected: 0 , < V1.0.202N (custom)
    Create a notification for this product.
    Siemens SIMATIC Field PG M5 Affected: 0 , < V22.01.10 (custom)
    Create a notification for this product.
    Siemens SIMATIC Field PG M6 Affected: 0 , < V26.01.13 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC127E Affected: 0 , < V27.01.09 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC227G Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC277G Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC277G PRO Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC327G Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC377G Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC427E Affected: 0 , < V21.01.17 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC477E Affected: 0 , < V21.01.17 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC477E PRO Affected: 0 , < V21.01.17 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC627E Affected: 0 , < V25.02.12 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC647E Affected: 0 , < V25.02.12 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC677E Affected: 0 , < V25.02.12 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC847E Affected: 0 , < V25.02.12 (custom)
    Create a notification for this product.
    Siemens SIMATIC ITP1000 Affected: 0 , < V23.01.10 (custom)
    Create a notification for this product.
    Siemens SIPLUS IPC427E Affected: 0 , < V21.01.17 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2025-11-04T19:12:36.407Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.insyde.com/security-pledge"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.insyde.com/security-pledge/SA-2022020"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://security.netapp.com/advisory/ntap-20220217-0016/"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
              },
              {
                "url": "https://www.kb.cert.org/vuls/id/796611"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "affected": [
              {
                "defaultStatus": "unknown",
                "product": "RUGGEDCOM APE1808 - BIOS",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V1.0.202N",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC Field PG M5",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V22.01.10",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC Field PG M6",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V26.01.13",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC127E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V27.01.09",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC227G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC277G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC\u00a0IPC277G PRO",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC327G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC377G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC427E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.17",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC477E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.17",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC477E PRO",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.17",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC627E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.12",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC647E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.12",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC677E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.12",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC847E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.12",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC ITP1000",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V23.01.10",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS IPC427E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.17",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-08-11T12:22:11.112Z",
              "orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
              "shortName": "siemens-SADP"
            },
            "references": [
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-306654.html"
              }
            ],
            "x_adpType": "supplier"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "An issue was discovered in NvmExpressDxe in the kernel 5.0 through 5.5 in Insyde InsydeH2O. Because of an Untrusted Pointer Dereference that causes SMM memory corruption, an attacker may be able to write fixed or predictable data to SMRAM. Exploiting this issue could lead to escalating privileges to SMM."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-02-22T19:06:25.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.insyde.com/security-pledge"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.insyde.com/security-pledge/SA-2022020"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://security.netapp.com/advisory/ntap-20220217-0016/"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2021-41839",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "An issue was discovered in NvmExpressDxe in the kernel 5.0 through 5.5 in Insyde InsydeH2O. Because of an Untrusted Pointer Dereference that causes SMM memory corruption, an attacker may be able to write fixed or predictable data to SMRAM. Exploiting this issue could lead to escalating privileges to SMM."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.insyde.com/security-pledge",
                  "refsource": "MISC",
                  "url": "https://www.insyde.com/security-pledge"
                },
                {
                  "name": "https://www.insyde.com/security-pledge/SA-2022020",
                  "refsource": "MISC",
                  "url": "https://www.insyde.com/security-pledge/SA-2022020"
                },
                {
                  "name": "https://security.netapp.com/advisory/ntap-20220217-0016/",
                  "refsource": "CONFIRM",
                  "url": "https://security.netapp.com/advisory/ntap-20220217-0016/"
                },
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf",
                  "refsource": "CONFIRM",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2021-41839",
        "datePublished": "2022-02-03T01:37:10.000Z",
        "dateReserved": "2021-10-01T00:00:00.000Z",
        "dateUpdated": "2026-08-11T12:22:11.112Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2021-33627 (GCVE-0-2021-33627)

    Vulnerability from cvelistv5 – Published: 2022-02-03 01:30 – Updated: 2026-08-11 12:22
    VLAI
    Summary
    An issue was discovered in Insyde InsydeH2O Kernel 5.0 before 05.09.11, 5.1 before 05.17.11, 5.2 before 05.27.11, 5.3 before 05.36.11, 5.4 before 05.44.11, and 5.5 before 05.52.11 affecting FwBlockServiceSmm. Software SMI services that use the Communicate() function of the EFI_SMM_COMMUNICATION_PROTOCOL do not check whether the address of the buffer is valid, which allows use of SMRAM, MMIO, or OS kernel addresses.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Impacted products
    Vendor Product Version
    Siemens RUGGEDCOM APE1808 - BIOS Affected: 0 , < V1.0.202N (custom)
    Create a notification for this product.
    Siemens SIMATIC Field PG M5 Affected: 0 , < V22.01.10 (custom)
    Create a notification for this product.
    Siemens SIMATIC Field PG M6 Affected: 0 , < V26.01.13 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC127E Affected: 0 , < V27.01.09 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC227G Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC277G Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC277G PRO Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC327G Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC377G Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC427E Affected: 0 , < V21.01.17 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC477E Affected: 0 , < V21.01.17 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC477E PRO Affected: 0 , < V21.01.17 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC627E Affected: 0 , < V25.02.12 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC647E Affected: 0 , < V25.02.12 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC677E Affected: 0 , < V25.02.12 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC847E Affected: 0 , < V25.02.12 (custom)
    Create a notification for this product.
    Siemens SIMATIC ITP1000 Affected: 0 , < V23.01.10 (custom)
    Create a notification for this product.
    Siemens SIPLUS IPC427E Affected: 0 , < V21.01.17 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2025-11-04T19:12:32.043Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.insyde.com/security-pledge"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.insyde.com/security-pledge/SA-2022022"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://security.netapp.com/advisory/ntap-20220222-0002/"
              },
              {
                "url": "https://www.kb.cert.org/vuls/id/796611"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "affected": [
              {
                "defaultStatus": "unknown",
                "product": "RUGGEDCOM APE1808 - BIOS",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V1.0.202N",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC Field PG M5",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V22.01.10",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC Field PG M6",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V26.01.13",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC127E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V27.01.09",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC227G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC277G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC\u00a0IPC277G PRO",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC327G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC377G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC427E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.17",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC477E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.17",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC477E PRO",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.17",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC627E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.12",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC647E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.12",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC677E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.12",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC847E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.12",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC ITP1000",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V23.01.10",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS IPC427E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.17",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-08-11T12:22:07.040Z",
              "orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
              "shortName": "siemens-SADP"
            },
            "references": [
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-306654.html"
              }
            ],
            "x_adpType": "supplier"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "An issue was discovered in Insyde InsydeH2O Kernel 5.0 before 05.09.11, 5.1 before 05.17.11, 5.2 before 05.27.11, 5.3 before 05.36.11, 5.4 before 05.44.11, and 5.5 before 05.52.11 affecting FwBlockServiceSmm. Software SMI services that use the Communicate() function of the EFI_SMM_COMMUNICATION_PROTOCOL do not check whether the address of the buffer is valid, which allows use of SMRAM, MMIO, or OS kernel addresses."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-07-22T16:50:10.835Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://www.insyde.com/security-pledge"
            },
            {
              "url": "https://www.insyde.com/security-pledge/SA-2022022"
            },
            {
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
            },
            {
              "url": "https://security.netapp.com/advisory/ntap-20220222-0002/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2021-33627",
        "datePublished": "2022-02-03T01:30:36.000Z",
        "dateReserved": "2021-05-28T00:00:00.000Z",
        "dateUpdated": "2026-08-11T12:22:07.040Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2021-42060 (GCVE-0-2021-42060)

    Vulnerability from cvelistv5 – Published: 2022-02-03 01:27 – Updated: 2026-08-11 12:22
    VLAI
    Summary
    An issue was discovered in Insyde InsydeH2O Kernel 5.0 through 05.08.41, Kernel 5.1 through 05.16.41, Kernel 5.2 before 05.23.22, and Kernel 5.3 before 05.32.22. An Int15ServiceSmm SMM callout vulnerability allows an attacker to hijack execution flow of code running in System Management Mode. Exploiting this issue could lead to escalating privileges to SMM.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Impacted products
    Vendor Product Version
    Siemens RUGGEDCOM APE1808 - BIOS Affected: 0 , < V1.0.202N (custom)
    Create a notification for this product.
    Siemens SIMATIC Field PG M5 Affected: 0 , < V22.01.10 (custom)
    Create a notification for this product.
    Siemens SIMATIC Field PG M6 Affected: 0 , < V26.01.13 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC127E Affected: 0 , < V27.01.09 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC227G Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC277G Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC277G PRO Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC327G Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC377G Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC427E Affected: 0 , < V21.01.17 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC477E Affected: 0 , < V21.01.17 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC477E PRO Affected: 0 , < V21.01.17 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC627E Affected: 0 , < V25.02.12 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC647E Affected: 0 , < V25.02.12 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC677E Affected: 0 , < V25.02.12 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC847E Affected: 0 , < V25.02.12 (custom)
    Create a notification for this product.
    Siemens SIMATIC ITP1000 Affected: 0 , < V23.01.10 (custom)
    Create a notification for this product.
    Siemens SIPLUS IPC427E Affected: 0 , < V21.01.17 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2025-11-04T19:12:40.921Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.insyde.com/security-pledge"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.insyde.com/security-pledge/SA-2022007"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://security.netapp.com/advisory/ntap-20220217-0015/"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
              },
              {
                "url": "https://www.kb.cert.org/vuls/id/796611"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "affected": [
              {
                "defaultStatus": "unknown",
                "product": "RUGGEDCOM APE1808 - BIOS",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V1.0.202N",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC Field PG M5",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V22.01.10",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC Field PG M6",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V26.01.13",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC127E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V27.01.09",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC227G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC277G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC\u00a0IPC277G PRO",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC327G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC377G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC427E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.17",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC477E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.17",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC477E PRO",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.17",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC627E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.12",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC647E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.12",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC677E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.12",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC847E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.12",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC ITP1000",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V23.01.10",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS IPC427E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.17",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-08-11T12:22:15.909Z",
              "orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
              "shortName": "siemens-SADP"
            },
            "references": [
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-306654.html"
              }
            ],
            "x_adpType": "supplier"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "An issue was discovered in Insyde InsydeH2O Kernel 5.0 through 05.08.41, Kernel 5.1 through 05.16.41, Kernel 5.2 before 05.23.22, and Kernel 5.3 before 05.32.22. An Int15ServiceSmm SMM callout vulnerability allows an attacker to hijack execution flow of code running in System Management Mode. Exploiting this issue could lead to escalating privileges to SMM."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-02-22T19:06:42.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.insyde.com/security-pledge"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.insyde.com/security-pledge/SA-2022007"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://security.netapp.com/advisory/ntap-20220217-0015/"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2021-42060",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "An issue was discovered in Insyde InsydeH2O Kernel 5.0 through 05.08.41, Kernel 5.1 through 05.16.41, Kernel 5.2 before 05.23.22, and Kernel 5.3 before 05.32.22. An Int15ServiceSmm SMM callout vulnerability allows an attacker to hijack execution flow of code running in System Management Mode. Exploiting this issue could lead to escalating privileges to SMM."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.insyde.com/security-pledge",
                  "refsource": "MISC",
                  "url": "https://www.insyde.com/security-pledge"
                },
                {
                  "name": "https://www.insyde.com/security-pledge/SA-2022007",
                  "refsource": "MISC",
                  "url": "https://www.insyde.com/security-pledge/SA-2022007"
                },
                {
                  "name": "https://security.netapp.com/advisory/ntap-20220217-0015/",
                  "refsource": "CONFIRM",
                  "url": "https://security.netapp.com/advisory/ntap-20220217-0015/"
                },
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf",
                  "refsource": "CONFIRM",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2021-42060",
        "datePublished": "2022-02-03T01:27:34.000Z",
        "dateReserved": "2021-10-07T00:00:00.000Z",
        "dateUpdated": "2026-08-11T12:22:15.909Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2021-41837 (GCVE-0-2021-41837)

    Vulnerability from cvelistv5 – Published: 2022-02-03 01:23 – Updated: 2026-08-11 12:22
    VLAI
    Summary
    An issue was discovered in AhciBusDxe in the kernel 5.0 through 5.5 in Insyde InsydeH2O. Because of an Untrusted Pointer Dereference that causes SMM memory corruption, an attacker may be able to write fixed or predictable data to SMRAM. Exploiting this issue could lead to escalating privileges to SMM.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Impacted products
    Vendor Product Version
    Siemens RUGGEDCOM APE1808 - BIOS Affected: 0 , < V1.0.202N (custom)
    Create a notification for this product.
    Siemens SIMATIC Field PG M5 Affected: 0 , < V22.01.10 (custom)
    Create a notification for this product.
    Siemens SIMATIC Field PG M6 Affected: 0 , < V26.01.13 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC127E Affected: 0 , < V27.01.09 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC227G Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC277G Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC277G PRO Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC327G Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC377G Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC427E Affected: 0 , < V21.01.17 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC477E Affected: 0 , < V21.01.17 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC477E PRO Affected: 0 , < V21.01.17 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC627E Affected: 0 , < V25.02.12 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC647E Affected: 0 , < V25.02.12 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC677E Affected: 0 , < V25.02.12 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC847E Affected: 0 , < V25.02.12 (custom)
    Create a notification for this product.
    Siemens SIMATIC ITP1000 Affected: 0 , < V23.01.10 (custom)
    Create a notification for this product.
    Siemens SIPLUS IPC427E Affected: 0 , < V21.01.17 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2025-11-04T19:12:34.238Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.insyde.com/security-pledge"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.insyde.com/security-pledge/SA-2022024"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://security.netapp.com/advisory/ntap-20220222-0003/"
              },
              {
                "url": "https://www.kb.cert.org/vuls/id/796611"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "affected": [
              {
                "defaultStatus": "unknown",
                "product": "RUGGEDCOM APE1808 - BIOS",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V1.0.202N",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC Field PG M5",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V22.01.10",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC Field PG M6",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V26.01.13",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC127E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V27.01.09",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC227G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC277G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC\u00a0IPC277G PRO",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC327G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC377G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC427E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.17",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC477E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.17",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC477E PRO",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.17",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC627E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.12",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC647E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.12",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC677E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.12",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC847E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.12",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC ITP1000",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V23.01.10",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS IPC427E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.17",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-08-11T12:22:08.782Z",
              "orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
              "shortName": "siemens-SADP"
            },
            "references": [
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-306654.html"
              }
            ],
            "x_adpType": "supplier"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "An issue was discovered in AhciBusDxe in the kernel 5.0 through 5.5 in Insyde InsydeH2O. Because of an Untrusted Pointer Dereference that causes SMM memory corruption, an attacker may be able to write fixed or predictable data to SMRAM. Exploiting this issue could lead to escalating privileges to SMM."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-02-23T15:06:18.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.insyde.com/security-pledge"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.insyde.com/security-pledge/SA-2022024"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://security.netapp.com/advisory/ntap-20220222-0003/"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2021-41837",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "An issue was discovered in AhciBusDxe in the kernel 5.0 through 5.5 in Insyde InsydeH2O. Because of an Untrusted Pointer Dereference that causes SMM memory corruption, an attacker may be able to write fixed or predictable data to SMRAM. Exploiting this issue could lead to escalating privileges to SMM."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.insyde.com/security-pledge",
                  "refsource": "MISC",
                  "url": "https://www.insyde.com/security-pledge"
                },
                {
                  "name": "https://www.insyde.com/security-pledge/SA-2022024",
                  "refsource": "MISC",
                  "url": "https://www.insyde.com/security-pledge/SA-2022024"
                },
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf",
                  "refsource": "CONFIRM",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
                },
                {
                  "name": "https://security.netapp.com/advisory/ntap-20220222-0003/",
                  "refsource": "CONFIRM",
                  "url": "https://security.netapp.com/advisory/ntap-20220222-0003/"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2021-41837",
        "datePublished": "2022-02-03T01:23:39.000Z",
        "dateReserved": "2021-10-01T00:00:00.000Z",
        "dateUpdated": "2026-08-11T12:22:08.782Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2021-41840 (GCVE-0-2021-41840)

    Vulnerability from cvelistv5 – Published: 2022-02-03 01:20 – Updated: 2026-08-11 12:22
    VLAI
    Summary
    An issue was discovered in NvmExpressDxe in the kernel 5.0 through 5.5 in Insyde InsydeH2O. There is an SMM callout that allows an attacker to access the System Management Mode and execute arbitrary code. This occurs because of Inclusion of Functionality from an Untrusted Control Sphere.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Impacted products
    Vendor Product Version
    Siemens SIMATIC Field PG M5 Affected: 0 , < V22.01.10 (custom)
    Create a notification for this product.
    Siemens SIMATIC Field PG M6 Affected: 0 , < V26.01.13 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC127E Affected: 0 , < V27.01.09 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC227G Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC277G Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC277G PRO Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC327G Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC377G Affected: 0 , < V28.01.04 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC427E Affected: 0 , < V21.01.17 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC477E Affected: 0 , < V21.01.17 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC477E PRO Affected: 0 , < V21.01.17 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC627E Affected: 0 , < V25.02.12 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC647E Affected: 0 , < V25.02.12 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC677E Affected: 0 , < V25.02.12 (custom)
    Create a notification for this product.
    Siemens SIMATIC IPC847E Affected: 0 , < V25.02.12 (custom)
    Create a notification for this product.
    Siemens SIMATIC ITP1000 Affected: 0 , < V23.01.10 (custom)
    Create a notification for this product.
    Siemens SIPLUS IPC427E Affected: 0 , < V21.01.17 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2025-11-04T19:12:37.499Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.insyde.com/security-pledge"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.insyde.com/security-pledge/SA-2022018"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://security.netapp.com/advisory/ntap-20220217-0014/"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
              },
              {
                "url": "https://www.kb.cert.org/vuls/id/796611"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "affected": [
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC Field PG M5",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V22.01.10",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC Field PG M6",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V26.01.13",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC127E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V27.01.09",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC227G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC277G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC\u00a0IPC277G PRO",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC327G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC377G",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V28.01.04",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC427E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.17",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC477E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.17",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC477E PRO",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.17",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC627E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.12",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC647E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.12",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC677E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.12",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC IPC847E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V25.02.12",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIMATIC ITP1000",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V23.01.10",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "defaultStatus": "unknown",
                "product": "SIPLUS IPC427E",
                "vendor": "Siemens",
                "versions": [
                  {
                    "lessThan": "V21.01.17",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-08-11T12:22:12.302Z",
              "orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
              "shortName": "siemens-SADP"
            },
            "references": [
              {
                "url": "https://cert-portal.siemens.com/productcert/html/ssa-306654.html"
              }
            ],
            "x_adpType": "supplier"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "An issue was discovered in NvmExpressDxe in the kernel 5.0 through 5.5 in Insyde InsydeH2O. There is an SMM callout that allows an attacker to access the System Management Mode and execute arbitrary code. This occurs because of Inclusion of Functionality from an Untrusted Control Sphere."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-02-22T19:06:58.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.insyde.com/security-pledge"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.insyde.com/security-pledge/SA-2022018"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://security.netapp.com/advisory/ntap-20220217-0014/"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2021-41840",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "An issue was discovered in NvmExpressDxe in the kernel 5.0 through 5.5 in Insyde InsydeH2O. There is an SMM callout that allows an attacker to access the System Management Mode and execute arbitrary code. This occurs because of Inclusion of Functionality from an Untrusted Control Sphere."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.insyde.com/security-pledge",
                  "refsource": "MISC",
                  "url": "https://www.insyde.com/security-pledge"
                },
                {
                  "name": "https://www.insyde.com/security-pledge/SA-2022018",
                  "refsource": "MISC",
                  "url": "https://www.insyde.com/security-pledge/SA-2022018"
                },
                {
                  "name": "https://security.netapp.com/advisory/ntap-20220217-0014/",
                  "refsource": "CONFIRM",
                  "url": "https://security.netapp.com/advisory/ntap-20220217-0014/"
                },
                {
                  "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf",
                  "refsource": "CONFIRM",
                  "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-306654.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2021-41840",
        "datePublished": "2022-02-03T01:20:07.000Z",
        "dateReserved": "2021-10-01T00:00:00.000Z",
        "dateUpdated": "2026-08-11T12:22:12.302Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }