Search criteria

59 vulnerabilities found for SIMATIC WinCC Runtime Advanced by Siemens

VAR-202103-1464

Vulnerability from variot - Updated: 2025-12-22 21:36

An OpenSSL TLS server may crash if sent a maliciously crafted renegotiation ClientHello message from a client. If a TLSv1.2 renegotiation ClientHello omits the signature_algorithms extension (where it was present in the initial ClientHello), but includes a signature_algorithms_cert extension then a NULL pointer dereference will result, leading to a crash and a denial of service attack. A server is only vulnerable if it has TLSv1.2 and renegotiation enabled (which is the default configuration). OpenSSL TLS clients are not impacted by this issue. All OpenSSL 1.1.1 versions are affected by this issue. Users of these versions should upgrade to OpenSSL 1.1.1k. OpenSSL 1.0.2 is not impacted by this issue. Fixed in OpenSSL 1.1.1k (Affected 1.1.1-1.1.1j). The product supports a variety of encryption algorithms, including symmetric ciphers, hash algorithms, secure hash algorithms, etc. On March 25, 2021, the OpenSSL Project released a security advisory, OpenSSL Security Advisory [25 March 2021], that disclosed two vulnerabilities. Exploitation of these vulnerabilities could allow an malicious user to use a valid non-certificate authority (CA) certificate to act as a CA and sign a certificate for an arbitrary organization, user or device, or to cause a denial of service (DoS) condition. This advisory is available at the following link:tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-openssl-2021-GHY28dJd.

Bug Fix(es):

This update includes various bug fixes and enhancements. Space precludes documenting all of these changes in this advisory. Bugs fixed (https://bugzilla.redhat.com/):

1803849 - [RFE] Include per volume encryption with Vault integration in RHCS 4.1 1814681 - [RFE] use topologySpreadConstraints to evenly spread OSDs across hosts 1840004 - CVE-2020-7608 nodejs-yargs-parser: prototype pollution vulnerability 1850089 - OBC CRD is outdated and leads to missing columns in get queries 1860594 - Toolbox pod should have toleration for OCS tainted nodes 1861104 - OCS podDisruptionBudget prevents successful OCP upgrades 1861878 - [RFE] use appropriate PDB values for OSD 1866301 - [RHOCS Usability Study][Installation] “Create storage cluster” should be a part of the installation flow or need to be emphasized as a crucial step. 1869406 - must-gather should include historical pod logs 1872730 - [RFE][External mode] Re-configure noobaa to use the updated RGW endpoint from the RHCS cluster 1874367 - "Create Backing Store" page doesn't allow to select already defined k8s secret as target bucket credentials when Google Cloud Storage is selected as a provider 1883371 - CVE-2020-26160 jwt-go: access restriction bypass vulnerability 1886112 - log message flood with Reconciling StorageCluster","Request.Namespace":"openshift-storage","Request.Name":"ocs-storagecluster" 1886416 - Uninstall 4.6: ocs-operator logging regarding noobaa-core PVC needs change 1886638 - CVE-2020-8565 kubernetes: Incomplete fix for CVE-2019-11250 allows for token leak in logs when logLevel >= 9 1888839 - Create public route for ceph-rgw service 1892622 - [GSS] Noobaa management dashboard reporting High number of issues when the cluster is in healthy state 1893611 - Skip ceph commands collection attempt if must-gather helper pod is not created 1893613 - must-gather tries to collect ceph commands in external mode when storagecluster already deleted 1893619 - OCS must-gather: Inspect errors for cephobjectoreUser and few ceph commandd when storage cluster does not exist 1894412 - [RFE][External] RGW metrics should be made available even if anything else except 9283 is provided as the monitoring-endpoint-port 1896338 - OCS upgrade from 4.6 to 4.7 build failed 1897246 - OCS - ceph historical logs collection 1897635 - CVE-2020-28362 golang: math/big: panic during recursive division of very large numbers 1898509 - [Tracker][RHV #1899565] Deployment on RHV/oVirt storage class ovirt-csi-sc failing 1898680 - CVE-2020-7774 nodejs-y18n: prototype pollution vulnerability 1898808 - Rook-Ceph crash collector pod should not run on non-ocs node 1900711 - [RFE] Alerting for Namespace buckets and resources 1900722 - Failed to init upgrade process on noobaa-core-0 1900749 - Namespace Resource reported as Healthy when target bucket deleted 1900760 - RPC call for Namespace resource creation allows invalid target bucket names 1901134 - OCS - ceph historical logs collection 1902192 - [RFE][External] RGW metrics should be made available even if anything else except 9283 is provided as the monitoring-endpoint-port 1902685 - Too strict Content-Length header check refuses valid upload requests 1902711 - Tracker for Bug #1903078 Deleting VolumeSnapshotClass makes VolumeSnapshot not Ready 1903973 - [Azure][ROKS] Set SSD tuning (tuneFastDeviceClass) as default for OSD devices in Azure/ROKS platform 1903975 - Add "ceph df detail" for ocs must-gather to enable support to debug compression 1904302 - [GSS] ceph_daemon label includes references to a replaced OSD that cause a prometheus ruleset to fail 1904929 - [GSS][RFE]Reduce debug level for logs of Nooba Endpoint pod 1907318 - Unable to deploy & upgrade to ocs 4.7 - missing postgres image reference 1908414 - [GSS][VMWare][ROKS] rgw pods are not showing up in OCS 4.5 - due to pg_limit issue 1908678 - ocs-osd-removal job failed with "Invalid value" error when using multiple ids 1909268 - OCS 4.7 UI install -All OCS operator pods respin after storagecluster creation 1909488 - [NooBaa CLI] CLI status command looks for wrong DB PV name 1909745 - pv-pool backing store name restriction should be at 43 characters 1910705 - OBCs are stuck in a Pending state 1911131 - Bucket stats in the NB dashboard are incorrect 1911266 - Backingstore phase is ready, modecode is INITIALIZING 1911627 - CVE-2020-26289 nodejs-date-and-time: ReDoS in parsing via date.compile 1911789 - Data deduplication does not work properly 1912421 - [RFE] noobaa cli allow the creation of BackingStores with already existing secrets 1912894 - OCS storagecluster is Progressing state and some noobaa pods missing with latest 4.7 build -4.7.0-223.ci and storagecluster reflected as 4.8.0 instead of 4.7.0 1913149 - make must-gather backward compatibility for version <4.6 1913357 - ocs-operator should show error when flexible scaling and arbiter are both enabled at the same time 1914132 - No metrics available in the Object Service Dashboard in OCS 4.7, logs show "failed to retrieve metrics exporter servicemonitor" 1914159 - When OCS was deployed using arbiter mode mon's are going into CLBO state, ceph version = 14.2.11-95 1914215 - must-gather fails to delete the completed state compute-xx-debug pods after successful completion 1915111 - OCS OSD selection algorithm is making some strange choices. 1915261 - Deleted MCG CRs are stuck in a 'Deleting' state 1915445 - Uninstall 4.7: Storagecluster deletion stuck on a partially created KMS enabled OCS cluster + support TLS configuration for KMS 1915644 - update noobaa db label in must-gather to collect db pod in noobaa dir 1915698 - There is missing noobaa-core-0 pod after upgrade from OCS 4.6 to OCS 4.7 1915706 - [Azure][RBD] PV taking longer time ~ 9 minutes to get deleted 1915730 - [ocs-operator] Create public route for ceph-rgw service 1915737 - Improve ocs-operator logging during uninstall to be more verbose, to understand reasons for failures - e.g. for Bug 1915445 1915758 - improve noobaa logging in case of uninstall - logs do not specify clearly the resource on which deletion is stuck 1915807 - Arbiter: OCS Install failed when used label = topology.kubernetes.io/zone instead of deprecated failureDomain label 1915851 - OCS PodDisruptionBudget redesign for OSDs to allow multiple nodes to drain in the same failure domain 1915953 - Must-gather takes hours to complete if the OCS cluster is not fully deployed, delay seen in ceph command collection step 1916850 - Uninstall 4.7- rook: Storagecluster deletion stuck on a partially created KMS enabled OCS cluster(OSD creation failed) 1917253 - Restore-pvc creation fails with error "csi-vol-* has unsupported quota" 1917815 - [IBM Z and Power] OSD pods restarting due to OOM during upgrade test using ocs-ci 1918360 - collect timestamp for must-gather commands and also the total time taken for must-gather to complete 1918750 - CVE-2021-3114 golang: crypto/elliptic: incorrect operations on the P-224 curve 1918925 - noobaa operator pod logs messages for other components - like rook-ceph-mon, csi-pods, new Storageclass, etc 1918938 - ocs-operator has Error logs with "unable to deploy Prometheus rules" 1919967 - MCG RPC calls time out and the system is unresponsive 1920202 - RGW pod did not get created when OCS was deployed using arbiter mode 1920498 - [IBM Z] OSDs are OOM killed and storage cluster goes into error state during ocs-ci tier1 pvc expansion tests 1920507 - Creation of cephblockpool with compression failed on timeout 1921521 - Add support for VAULT_SKIP_VERIFY option in Ceph-CSI 1921540 - RBD PVC creation fails with error "invalid encryption kms configuration: "POD_NAMESPACE" is not set" 1921609 - MongoNetworkError messages in noobaa-core logs 1921625 - 'Not Found: Secret "noobaa-root-master-key" message' in noobaa logs and cli output when kms is configured 1922064 - uninstall on VMware LSO+ arbiter with 4 OSDs in Pending state: Storagecluster deletion stuck, waiting for cephcluster to be deleted 1922108 - OCS 4.7 4.7.0-242.ci and beyond: osd pods are not created 1922113 - noobaa-db pod init container is crashing after OCS upgrade from OCS 4.6 to OCS 4.7 1922119 - PVC snapshot creation failing on OCP4.6-OCS 4.7 cluster 1922421 - [ROKS] OCS deployment stuck at mon pod in pending state 1922954 - [IBM Z] OCS: Failed tests because of osd deviceset restarts 1924185 - Object Service Dashboard shows alerts related to "system-internal-storage-pool" in OCS 4.7 1924211 - 4.7.0-249.ci: RGW pod not deployed, rook logs show - failed to create object store "must be no more than 63 characters" 1924634 - MG terminal logs show pods "compute-x-debug" not found even though pods are in Running state 1924784 - RBD PVC creation fails with error "invalid encryption kms configuration: failed to parse kms configuration" 1924792 - RBD PVC creation fails with error "invalid encryption kms configuration: failed to parse kms configuration" 1925055 - OSD pod stuck in Init:CrashLoopBackOff following Node maintenance in OCP upgrade from OCP 4.7 to 4.7 nightly 1925179 - MG fix [continuation from bug 1893619]: Do not attempt creating helper pod if storagecluster/cephcluster already deleted 1925249 - KMS resources should be garbage collected when StorageCluster is deleted 1925533 - [GSS] Unable to install Noobaa in AWS govcloud 1926182 - [RFE] Support disabling reconciliation of monitoring related resources using a dedicated reconcile strategy flag 1926617 - osds are in Init:CrashLoopBackOff with rgw in CrashLoopBackOff on KMS enabled cluster 1926717 - Only one NOOBAA_ROOT_SECRET_PATH key created in vault when the same backend path is used for multiple OCS clusters 1926831 - [IBM][ROKS] Deploy RGW pods only if IBM COS is not available on platform 1927128 - [Tracker for BZ #1937088] When Performed add capacity over arbiter mode cluster ceph health reports PG_AVAILABILITY Reduced data availability: 25 pgs inactive, 25 pgs incomplete 1927138 - must-gather skip collection of ceph in every run 1927186 - Configure pv-pool as backing store if cos creds secret not found in IBM Cloud 1927317 - [Arbiter] Storage Cluster installation did not started because ocs-operator was Expecting 8 node found 4 1927330 - Namespacestore-backed OBCs are stuck on Pending 1927338 - Uninstall OCS: Include events for major CRs to know the cause of deletion getting stuck 1927885 - OCS 4.7: ocs operator pod in 1/1 state even when Storagecluster is in Progressing state 1928063 - For FD: rack: actual osd pod distribution and OSD placement in rack under ceph osd tree output do not match 1928451 - MCG CLI command of diagnose doesn't work on windows 1928471 - [Deployment blocker] Ceph OSDs do not register properly in the CRUSH map 1928487 - MCG CLI - noobaa ui command shows wss instead of https 1928642 - [IBM Z] rook-ceph-rgw pods restarts continously with ocs version 4.6.3 due to liveness probe failure 1931191 - Backing/namespacestores are stuck on Creating with credentials errors 1931810 - LSO deployment(flexibleScaling:true): 100% PGS unknown even though ceph osd tree placement is correct(root cause diff from bug 1928471) 1931839 - OSD in state init:CrashLoopBackOff with KMS signed certificates 1932400 - Namespacestore deletion takes 15 minutes 1933607 - Prevent reconcile of labels on all monitoring resources deployed by ocs-operator 1933609 - Prevent reconcile of labels on all monitoring resources deployed by rook 1933736 - Allow shrinking the cluster by removing OSDs 1934000 - Improve error logging for kv-v2 while using encryption with KMS 1934990 - Ceph health ERR post node drain on KMS encryption enabled cluster 1935342 - [RFE] Add OSD flapping alert 1936545 - [Tracker for BZ #1938669] setuid and setgid file bits are not retained after a OCS CephFS CSI restore 1936877 - Include at OCS Multi-Cloud Object Gateway core container image the fixes on CVEs from RHEL8 on "nodejs" 1937070 - Storage cluster cannot be uninstalled when cluster not fully configured 1937100 - [RGW][notification][kafka]: notification fails with error: pubsub endpoint configuration error: unknown schema in: kafka 1937245 - csi-cephfsplugin pods CrashLoopBackoff in fresh 4.6 cluster due to conflict with kube-rbac-proxy 1937768 - OBC with Cache BucketPolicy stuck on pending 1939026 - ServiceUnavailable when calling the CreateBucket operation (reached max retries: 4): Reduce your request rate 1939472 - Failure domain set incorrectly to zone if flexible scaling is enabled but there are >= 3 zones 1939617 - [Arbiter] Mons cannot be failed over in stretch mode 1940440 - noobaa migration pod is deleted on failure and logs are not available for inspection 1940476 - Backingstore deletion hangs 1940957 - Deletion of Rejected NamespaceStore is stuck even when target bucket and bucketclass are deleted 1941647 - OCS deployment fails when no backend path is specified for cluster wide encryption using KMS 1941977 - rook-ceph-osd-X gets stuck in initcontainer expand-encrypted-bluefs 1942344 - No permissions in /etc/passwd leads to fail noobaa-operaor 1942350 - No permissions in /etc/passwd leads to fail noobaa-operaor 1942519 - MCG should not use KMS to store encryption keys if cluster wide encryption is not enabled using KMS 1943275 - OSD pods re-spun after "add capacity" on cluster with KMS 1943596 - [Tracker for BZ #1944611][Arbiter] When Performed zone(zone=a) Power off and Power On, 3 mon pod(zone=b,c) goes in CLBO after node Power off and 2 Osd(zone=a) goes in CLBO after node Power on 1944980 - Noobaa deployment fails when no KMS backend path is provided during storagecluster creation 1946592 - [Arbiter] When both the rgw pod hosting nodes are down, the rgw service is unavailable 1946837 - OCS 4.7 Arbiter Mode Cluster becomes stuck when entire zone is shutdown 1955328 - Upgrade of noobaa DB failed when upgrading OCS 4.6 to 4.7 1955601 - CVE-2021-3528 NooBaa: noobaa-operator leaking RPC AuthToken into log files 1957187 - Update to RHCS 4.2z1 Ceph container image at OCS 4.7.0 1957639 - Noobaa migrate job is failing when upgrading OCS 4.6.4 to 4.7 on FIPS environment

  1. -----BEGIN PGP SIGNED MESSAGE----- Hash: SHA256

====================================================================
Red Hat Security Advisory

Synopsis: Moderate: Red Hat OpenShift Container Storage 4.6.5 security and bug fix update Advisory ID: RHSA-2021:2479-01 Product: Red Hat OpenShift Container Storage Advisory URL: https://access.redhat.com/errata/RHSA-2021:2479 Issue date: 2021-06-17 CVE Names: CVE-2016-10228 CVE-2017-14502 CVE-2019-2708 CVE-2019-3842 CVE-2019-9169 CVE-2019-13012 CVE-2019-14866 CVE-2019-25013 CVE-2020-8231 CVE-2020-8284 CVE-2020-8285 CVE-2020-8286 CVE-2020-8927 CVE-2020-9948 CVE-2020-9951 CVE-2020-9983 CVE-2020-13434 CVE-2020-13543 CVE-2020-13584 CVE-2020-13776 CVE-2020-15358 CVE-2020-24977 CVE-2020-25659 CVE-2020-25678 CVE-2020-26116 CVE-2020-26137 CVE-2020-27618 CVE-2020-27619 CVE-2020-27783 CVE-2020-28196 CVE-2020-29361 CVE-2020-29362 CVE-2020-29363 CVE-2020-36242 CVE-2021-3139 CVE-2021-3177 CVE-2021-3326 CVE-2021-3449 CVE-2021-3450 CVE-2021-3528 CVE-2021-20305 CVE-2021-23239 CVE-2021-23240 CVE-2021-23336 ==================================================================== 1. Summary:

Updated images that fix one security issue and several bugs are now available for Red Hat OpenShift Container Storage 4.6.5 on Red Hat Enterprise Linux 8 from Red Hat Container Registry.

Red Hat Product Security has rated this update as having a security impact of Moderate. A Common Vulnerability Scoring System (CVSS) base score, which gives a detailed severity rating, is available for each vulnerability from the CVE link(s) in the References section.

  1. Description:

Red Hat OpenShift Container Storage is software-defined storage integrated with and optimized for the Red Hat OpenShift Container Platform. Red Hat OpenShift Container Storage is a highly scalable, production-grade persistent storage for stateful applications running in the Red Hat OpenShift Container Platform. In addition to persistent storage, Red Hat OpenShift Container Storage provisions a multicloud data management service with an S3 compatible API.

Security Fix(es):

  • NooBaa: noobaa-operator leaking RPC AuthToken into log files (CVE-2021-3528)

For more details about the security issue(s), including the impact, a CVSS score, and other related information, refer to the CVE page(s) listed in the References section.

Bug Fix(es):

  • Currently, a newly restored PVC cannot be mounted if some of the OpenShift Container Platform nodes are running on a version of Red Hat Enterprise Linux which is less than 8.2, and the snapshot from which the PVC was restored is deleted. Workaround: Do not delete the snapshot from which the PVC was restored until the restored PVC is deleted. (BZ#1962483)

  • Previously, the default backingstore was not created on AWS S3 when OpenShift Container Storage was deployed, due to incorrect identification of AWS S3. With this update, the default backingstore gets created when OpenShift Container Storage is deployed on AWS S3. (BZ#1927307)

  • Previously, log messages were printed to the endpoint pod log even if the debug option was not set. With this update, the log messages are printed to the endpoint pod log only when the debug option is set. (BZ#1938106)

  • Previously, the PVCs could not be provisioned as the rook-ceph-mds did not register the pod IP on the monitor servers, and hence every mount on the filesystem timed out, resulting in CephFS volume provisioning failure. With this update, an argument --public-addr=podIP is added to the MDS pod when the host network is not enabled, and hence the CephFS volume provisioning does not fail. (BZ#1949558)

  • Previously, OpenShift Container Storage 4.2 clusters were not updated with the correct cache value, and hence MDSs in standby-replay might report an oversized cache, as rook did not apply the mds_cache_memory_limit argument during upgrades. With this update, the mds_cache_memory_limit argument is applied during upgrades and the mds daemon operates normally. (BZ#1951348)

  • Previously, the coredumps were not generated in the correct location as rook was setting the config option log_file to an empty string since logging happened on stdout and not on the files, and hence Ceph read the value of the log_file to build the dump path. With this update, rook does not set the log_file and keeps Ceph's internal default, and hence the coredumps are generated in the correct location and are accessible under /var/log/ceph/. (BZ#1938049)

  • Previously, Ceph became inaccessible, as the mons lose quorum if a mon pod was drained while another mon was failing over. With this update, voluntary mon drains are prevented while a mon is failing over, and hence Ceph does not become inaccessible. (BZ#1946573)

  • Previously, the mon quorum was at risk, as the operator could erroneously remove the new mon if the operator was restarted during a mon failover. With this update, the operator completes the same mon failover after the operator is restarted, and hence the mon quorum is more reliable in the node drains and mon failover scenarios. (BZ#1959983)

All users of Red Hat OpenShift Container Storage are advised to pull these new images from the Red Hat Container Registry.

  1. Solution:

Before applying this update, make sure all previously released errata relevant to your system have been applied.

For details on how to apply this update, refer to:

https://access.redhat.com/articles/11258

  1. Bugs fixed (https://bugzilla.redhat.com/):

1938106 - [GSS][RFE]Reduce debug level for logs of Nooba Endpoint pod 1950915 - XSS Vulnerability with Noobaa version 5.5.0-3bacc6b 1951348 - [GSS][CephFS] health warning "MDS cache is too large (3GB/1GB); 0 inodes in use by clients, 0 stray files" for the standby-replay 1951600 - [4.6.z][Clone of BZ #1936545] setuid and setgid file bits are not retained after a OCS CephFS CSI restore 1955601 - CVE-2021-3528 NooBaa: noobaa-operator leaking RPC AuthToken into log files 1957189 - [Rebase] Use RHCS4.2z1 container image with OCS 4..6.5[may require doc update for external mode min supported RHCS version] 1959980 - When a node is being drained, increase the mon failover timeout to prevent unnecessary mon failover 1959983 - [GSS][mon] rook-operator scales mons to 4 after healthCheck timeout 1962483 - [RHEL7][RBD][4.6.z clone] FailedMount error when using restored PVC on app pod

  1. References:

https://access.redhat.com/security/cve/CVE-2016-10228 https://access.redhat.com/security/cve/CVE-2017-14502 https://access.redhat.com/security/cve/CVE-2019-2708 https://access.redhat.com/security/cve/CVE-2019-3842 https://access.redhat.com/security/cve/CVE-2019-9169 https://access.redhat.com/security/cve/CVE-2019-13012 https://access.redhat.com/security/cve/CVE-2019-14866 https://access.redhat.com/security/cve/CVE-2019-25013 https://access.redhat.com/security/cve/CVE-2020-8231 https://access.redhat.com/security/cve/CVE-2020-8284 https://access.redhat.com/security/cve/CVE-2020-8285 https://access.redhat.com/security/cve/CVE-2020-8286 https://access.redhat.com/security/cve/CVE-2020-8927 https://access.redhat.com/security/cve/CVE-2020-9948 https://access.redhat.com/security/cve/CVE-2020-9951 https://access.redhat.com/security/cve/CVE-2020-9983 https://access.redhat.com/security/cve/CVE-2020-13434 https://access.redhat.com/security/cve/CVE-2020-13543 https://access.redhat.com/security/cve/CVE-2020-13584 https://access.redhat.com/security/cve/CVE-2020-13776 https://access.redhat.com/security/cve/CVE-2020-15358 https://access.redhat.com/security/cve/CVE-2020-24977 https://access.redhat.com/security/cve/CVE-2020-25659 https://access.redhat.com/security/cve/CVE-2020-25678 https://access.redhat.com/security/cve/CVE-2020-26116 https://access.redhat.com/security/cve/CVE-2020-26137 https://access.redhat.com/security/cve/CVE-2020-27618 https://access.redhat.com/security/cve/CVE-2020-27619 https://access.redhat.com/security/cve/CVE-2020-27783 https://access.redhat.com/security/cve/CVE-2020-28196 https://access.redhat.com/security/cve/CVE-2020-29361 https://access.redhat.com/security/cve/CVE-2020-29362 https://access.redhat.com/security/cve/CVE-2020-29363 https://access.redhat.com/security/cve/CVE-2020-36242 https://access.redhat.com/security/cve/CVE-2021-3139 https://access.redhat.com/security/cve/CVE-2021-3177 https://access.redhat.com/security/cve/CVE-2021-3326 https://access.redhat.com/security/cve/CVE-2021-3449 https://access.redhat.com/security/cve/CVE-2021-3450 https://access.redhat.com/security/cve/CVE-2021-3528 https://access.redhat.com/security/cve/CVE-2021-20305 https://access.redhat.com/security/cve/CVE-2021-23239 https://access.redhat.com/security/cve/CVE-2021-23240 https://access.redhat.com/security/cve/CVE-2021-23336 https://access.redhat.com/security/updates/classification/#moderate

  1. Contact:

The Red Hat security contact is secalert@redhat.com. More contact details at https://access.redhat.com/security/team/contact/

Copyright 2021 Red Hat, Inc. -----BEGIN PGP SIGNATURE----- Version: GnuPG v1

iQIVAwUBYMtu/9zjgjWX9erEAQh6fhAAm9UPxF0e8ubzCEae+bkQAduwCkzpQ0ND Q1/UcDAAc4ueEhBrwXPhOLrgfBj+VG+QA19YZcNPzbW7I48RGjCm5WccnUyEbFAo FKTspCZW7FkXKBU15u58c/sFCGa4/Yuu+IpqCMuZ6lR2g9WHIBKdVtaB4y59AyfS v59cAorqZ3AoTX4lVys6HfDGySQWlg5P8t6ST72cUJjESi6U0HV00P7ECU2SFxCF HXA4gbXbZ1EPb/1+UkRRnXemJuT8SaRFRTrzj9woTrVAGQFvn+yjxLbZxVZb0WDd 6QeNpiJNICfL+/ExvEmGQucf7NcekYPWud11pnRUfQ+Uqsj+I7YoaepXAAolLzvN kAVVpFNsWADOVz7BrfSKoo4b38UCFOEUSd2d1ijCNE96Q9XyNUpn+kZqz0/wpBQC L+E5N9kEuaLyDBoI0wJAfoqU1NY4Cvl6lIMDgHUv2CE10zxhFwHCDulAfcQgxNQG sIbpSgSegq9HfZSDxa6Rtrox1I7oGhnBy10sIwUUH1+fxAusUk+Xrxf8hUv8KgDz V144yrGwN/6KVxh74A60bJX3ai12l6fC8bkmsxg5K1r/Dk4tUkQeXNdBbaK/rEKO AQs7YDab/0VA2qKtXDRkbnzqBRSbamDNOO/jd28nGMoclaIRHCzQgJRFv6Qb6dwT RCrstqAM5QQ=DHD0 -----END PGP SIGNATURE-----

-- RHSA-announce mailing list RHSA-announce@redhat.com https://listman.redhat.com/mailman/listinfo/rhsa-announce .

Bug fix:

  • RHACM 2.0.10 images (BZ #1940452)

  • Bugs fixed (https://bugzilla.redhat.com/):

1940452 - RHACM 2.0.10 images 1944286 - CVE-2021-23358 nodejs-underscore: Arbitrary code execution via the template function

  1. It is comprised of the Apache Tomcat Servlet container, JBoss HTTP Connector (mod_cluster), the PicketLink Vault extension for Apache Tomcat, and the Tomcat Native library. Bugs fixed (https://bugzilla.redhat.com/):

1918750 - CVE-2021-3114 golang: crypto/elliptic: incorrect operations on the P-224 curve 1918761 - CVE-2021-3115 golang: cmd/go: packages using cgo can cause arbitrary code execution at build time 1935897 - Release of OpenShift Serverless Serving 1.14.0 1935898 - Release of OpenShift Serverless Eventing 1.14.0


  1. Gentoo Linux Security Advisory GLSA 202103-03

                                        https://security.gentoo.org/

Severity: Normal Title: OpenSSL: Multiple vulnerabilities Date: March 31, 2021 Bugs: #769785, #777681 ID: 202103-03


Synopsis

Multiple vulnerabilities have been found in OpenSSL, the worst of which could allow remote attackers to cause a Denial of Service condition.

Background

OpenSSL is an Open Source toolkit implementing the Secure Sockets Layer (SSL v2/v3) and Transport Layer Security (TLS v1/v1.1/v1.2/v1.3) as well as a general purpose cryptography library.

Affected packages

 -------------------------------------------------------------------
  Package              /     Vulnerable     /            Unaffected
 -------------------------------------------------------------------

1 dev-libs/openssl < 1.1.1k >= 1.1.1k

Description

Multiple vulnerabilities have been discovered in OpenSSL. Please review the CVE identifiers referenced below for details.

Impact

Please review the referenced CVE identifiers for details.

Workaround

There is no known workaround at this time.

Resolution

All OpenSSL users should upgrade to the latest version:

# emerge --sync # emerge --ask --oneshot --verbose ">=dev-libs/openssl-1.1.1k"

References

[ 1 ] CVE-2021-23840 https://nvd.nist.gov/vuln/detail/CVE-2021-23840 [ 2 ] CVE-2021-23841 https://nvd.nist.gov/vuln/detail/CVE-2021-23841 [ 3 ] CVE-2021-3449 https://nvd.nist.gov/vuln/detail/CVE-2021-3449 [ 4 ] CVE-2021-3450 https://nvd.nist.gov/vuln/detail/CVE-2021-3450

Availability

This GLSA and any updates to it are available for viewing at the Gentoo Security Website:

https://security.gentoo.org/glsa/202103-03

Concerns?

Security is a primary focus of Gentoo Linux and ensuring the confidentiality and security of our users' machines is of utmost importance to us. Any security concerns should be addressed to security@gentoo.org or alternatively, you may file a bug at https://bugs.gentoo.org.

License

Copyright 2021 Gentoo Foundation, Inc; referenced text belongs to its owner(s).

The contents of this document are licensed under the Creative Commons - Attribution / Share Alike license.

https://creativecommons.org/licenses/by-sa/2.5 . Description:

Red Hat Advanced Cluster Management for Kubernetes 2.1.6 images

Red Hat Advanced Cluster Management for Kubernetes provides the capabilities to address common challenges that administrators and site reliability engineers face as they work across a range of public and private cloud environments. Clusters and applications are all visible and managed from a single console—with security policy built in.

Bug fixes:

  • RHACM 2.1.6 images (BZ#1940581)

  • When generating the import cluster string, it can include unescaped characters (BZ#1934184)

  • Bugs fixed (https://bugzilla.redhat.com/):

1853652 - CVE-2020-14040 golang.org/x/text: possibility to trigger an infinite loop in encoding/unicode could lead to crash 1929338 - CVE-2020-35149 mquery: Code injection via merge or clone operation 1934184 - When generating the import cluster string, it can include unescaped characters 1940581 - RHACM 2.1.6 images

  1. Summary:

Red Hat JBoss Core Services Pack Apache Server 2.4.37 Service Pack 7 zip release for RHEL 7, RHEL 8 and Microsoft Windows is available. This software, such as Apache HTTP Server, is common to multiple JBoss middleware products, and is packaged under Red Hat JBoss Core Services to allow for faster distribution of updates, and for a more consistent update experience.

This release adds the new Apache HTTP Server 2.4.37 Service Pack 7 packages that are part of the JBoss Core Services offering. Solution:

Before applying the update, back up your existing installation, including all applications, configuration files, databases and database settings, and so on.

The References section of this erratum contains a download link for the update. You must be logged in to download the update. Bugs fixed (https://bugzilla.redhat.com/):

1941547 - CVE-2021-3450 openssl: CA certificate check bypass with X509_V_FLAG_X509_STRICT 1941554 - CVE-2021-3449 openssl: NULL pointer dereference in signature_algorithms processing

  1. ========================================================================== Ubuntu Security Notice USN-5038-1 August 12, 2021

postgresql-10, postgresql-12, postgresql-13 vulnerabilities

A security issue affects these releases of Ubuntu and its derivatives:

  • Ubuntu 21.04
  • Ubuntu 20.04 LTS
  • Ubuntu 18.04 LTS

Summary:

Several security issues were fixed in PostgreSQL.

Software Description: - postgresql-13: Object-relational SQL database - postgresql-12: Object-relational SQL database - postgresql-10: Object-relational SQL database

Details:

It was discovered that the PostgresQL planner could create incorrect plans in certain circumstances. A remote attacker could use this issue to cause PostgreSQL to crash, resulting in a denial of service, or possibly obtain sensitive information from memory. (CVE-2021-3677)

It was discovered that PostgreSQL incorrectly handled certain SSL renegotiation ClientHello messages from clients. A remote attacker could possibly use this issue to cause PostgreSQL to crash, resulting in a denial of service. (CVE-2021-3449)

Update instructions:

The problem can be corrected by updating your system to the following package versions:

Ubuntu 21.04: postgresql-13 13.4-0ubuntu0.21.04.1

Ubuntu 20.04 LTS: postgresql-12 12.8-0ubuntu0.20.04.1

Ubuntu 18.04 LTS: postgresql-10 10.18-0ubuntu0.18.04.1

This update uses a new upstream release, which includes additional bug fixes. After a standard system update you need to restart PostgreSQL to make all the necessary changes

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202103-1464",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "graalvm",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "oracle",
        "version": "20.3.1.2"
      },
      {
        "model": "mysql workbench",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "oracle",
        "version": "8.0.23"
      },
      {
        "model": "simatic cloud connect 7",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "cloud volumes ontap mediator",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "netapp",
        "version": null
      },
      {
        "model": "simatic net cp 1543sp-1",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.1"
      },
      {
        "model": "simatic pdm",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "9.1.0.7"
      },
      {
        "model": "nessus network monitor",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenable",
        "version": "5.12.1"
      },
      {
        "model": "essbase",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "oracle",
        "version": "21.2"
      },
      {
        "model": "sma100",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "sonicwall",
        "version": "10.2.0.0"
      },
      {
        "model": "multi-domain management",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "checkpoint",
        "version": "r80.40"
      },
      {
        "model": "scalance s627-2m",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1"
      },
      {
        "model": "scalance xp-200",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.3"
      },
      {
        "model": "simatic process historian opc ua server",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2019"
      },
      {
        "model": "node.js",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "nodejs",
        "version": "10.0.0"
      },
      {
        "model": "simatic cp 1242-7 gprs v2",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "jd edwards world security",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "oracle",
        "version": "a9.4"
      },
      {
        "model": "scalance xr524-8c",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "6.4"
      },
      {
        "model": "tenable.sc",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "tenable",
        "version": "5.13.0"
      },
      {
        "model": "simatic rf188ci",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic net cp 1243-1",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "3.1"
      },
      {
        "model": "simatic rf185c",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "snapcenter",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "netapp",
        "version": null
      },
      {
        "model": "nessus network monitor",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenable",
        "version": "5.13.0"
      },
      {
        "model": "mysql connectors",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "oracle",
        "version": "8.0.23"
      },
      {
        "model": "simatic net cp 1543-1",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "3.0"
      },
      {
        "model": "tim 1531 irc",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.2"
      },
      {
        "model": "secure global desktop",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "oracle",
        "version": "5.6"
      },
      {
        "model": "node.js",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "nodejs",
        "version": "10.24.0"
      },
      {
        "model": "mysql server",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "oracle",
        "version": "5.7.33"
      },
      {
        "model": "scalance xr-300wg",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.3"
      },
      {
        "model": "sma100",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "sonicwall",
        "version": "10.2.1.0-17sv"
      },
      {
        "model": "simatic s7-1200 cpu 1217c",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "sinamics connect 300",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "node.js",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "nodejs",
        "version": "12.12.0"
      },
      {
        "model": "nessus network monitor",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenable",
        "version": "5.11.1"
      },
      {
        "model": "peoplesoft enterprise peopletools",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "oracle",
        "version": "8.58"
      },
      {
        "model": "scalance xm-400",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "6.4"
      },
      {
        "model": "simatic net cp1243-7 lte eu",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "3.1"
      },
      {
        "model": "quantum security gateway",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "checkpoint",
        "version": "r81"
      },
      {
        "model": "communications communications policy management",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "oracle",
        "version": "12.6.0.0.0"
      },
      {
        "model": "simatic rf360r",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "oncommand workflow automation",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "netapp",
        "version": null
      },
      {
        "model": "simatic hmi comfort outdoor panels",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic s7-1200 cpu 1214c",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance s615",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "6.2"
      },
      {
        "model": "mysql server",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "oracle",
        "version": "8.0.15"
      },
      {
        "model": "simatic mv500",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic s7-1200 cpu 1212fc",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "sinec pni",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "scalance xf-200ba",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.3"
      },
      {
        "model": "nessus network monitor",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenable",
        "version": "5.12.0"
      },
      {
        "model": "simatic rf188c",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic wincc runtime advanced",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "zfs storage appliance kit",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "oracle",
        "version": "8.8"
      },
      {
        "model": "simatic s7-1200 cpu 1211c",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "nessus",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "tenable",
        "version": "8.13.1"
      },
      {
        "model": "enterprise manager for storage management",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "oracle",
        "version": "13.4.0.0"
      },
      {
        "model": "multi-domain management",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "checkpoint",
        "version": "r81"
      },
      {
        "model": "peoplesoft enterprise peopletools",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "oracle",
        "version": "8.59"
      },
      {
        "model": "primavera unifier",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "oracle",
        "version": "17.7"
      },
      {
        "model": "simatic hmi basic panels 2nd generation",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "primavera unifier",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "oracle",
        "version": "19.12"
      },
      {
        "model": "scalance w700",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "6.5"
      },
      {
        "model": "e-series performance analyzer",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "netapp",
        "version": null
      },
      {
        "model": "scalance xr552-12",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "6.4"
      },
      {
        "model": "simatic net cp1243-7 lte us",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "3.1"
      },
      {
        "model": "node.js",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "nodejs",
        "version": "12.0.0"
      },
      {
        "model": "openssl",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "openssl",
        "version": "1.1.1"
      },
      {
        "model": "fedora",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "fedoraproject",
        "version": "34"
      },
      {
        "model": "graalvm",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "oracle",
        "version": "19.3.5"
      },
      {
        "model": "primavera unifier",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "oracle",
        "version": "20.12"
      },
      {
        "model": "node.js",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "nodejs",
        "version": "14.14.0"
      },
      {
        "model": "tenable.sc",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "tenable",
        "version": "5.17.0"
      },
      {
        "model": "web gateway cloud service",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mcafee",
        "version": "10.1.1"
      },
      {
        "model": "openssl",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "openssl",
        "version": "1.1.1k"
      },
      {
        "model": "simatic rf166c",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "linux",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "debian",
        "version": "9.0"
      },
      {
        "model": "scalance xc-200",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.3"
      },
      {
        "model": "simatic s7-1200 cpu 1215c",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "quantum security management",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "checkpoint",
        "version": "r80.40"
      },
      {
        "model": "scalance xr526-8c",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "6.4"
      },
      {
        "model": "node.js",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "nodejs",
        "version": "15.14.0"
      },
      {
        "model": "simatic s7-1500 cpu 1518-4 pn\\/dp mfp",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "linux",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "debian",
        "version": "10.0"
      },
      {
        "model": "web gateway cloud service",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mcafee",
        "version": "9.2.10"
      },
      {
        "model": "tim 1531 irc",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.0"
      },
      {
        "model": "primavera unifier",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "oracle",
        "version": "17.12"
      },
      {
        "model": "sinec infrastructure network services",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "1.0.1.1"
      },
      {
        "model": "graalvm",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "oracle",
        "version": "21.0.0.2"
      },
      {
        "model": "secure backup",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "oracle",
        "version": "18.1.0.1.0"
      },
      {
        "model": "nessus network monitor",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "tenable",
        "version": "5.11.0"
      },
      {
        "model": "storagegrid",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "netapp",
        "version": null
      },
      {
        "model": "peoplesoft enterprise peopletools",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "oracle",
        "version": "8.57"
      },
      {
        "model": "scalance sc-600",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.0"
      },
      {
        "model": "simatic pcs 7 telecontrol",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic s7-1200 cpu 1215 fc",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "node.js",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "nodejs",
        "version": "12.22.1"
      },
      {
        "model": "simatic rf186ci",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "web gateway",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mcafee",
        "version": "10.1.1"
      },
      {
        "model": "simatic net cp 1542sp-1 irc",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.1"
      },
      {
        "model": "capture client",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "sonicwall",
        "version": "3.5"
      },
      {
        "model": "simatic logon",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "1.6.0.2"
      },
      {
        "model": "simatic wincc telecontrol",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "active iq unified manager",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "netapp",
        "version": null
      },
      {
        "model": "sonicos",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "sonicwall",
        "version": "7.0.1.0"
      },
      {
        "model": "jd edwards enterpriseone tools",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "oracle",
        "version": "9.2.6.0"
      },
      {
        "model": "oncommand insight",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "netapp",
        "version": null
      },
      {
        "model": "simatic pcs neo",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "scalance s623",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1"
      },
      {
        "model": "scalance lpe9403",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic s7-1200 cpu 1214 fc",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "node.js",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "nodejs",
        "version": "10.13.0"
      },
      {
        "model": "log correlation engine",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "tenable",
        "version": "6.0.9"
      },
      {
        "model": "scalance m-800",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "6.2"
      },
      {
        "model": "simatic rf186c",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "web gateway cloud service",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mcafee",
        "version": "8.2.19"
      },
      {
        "model": "node.js",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "nodejs",
        "version": "14.0.0"
      },
      {
        "model": "primavera unifier",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "oracle",
        "version": "21.12"
      },
      {
        "model": "web gateway",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mcafee",
        "version": "9.2.10"
      },
      {
        "model": "node.js",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "nodejs",
        "version": "14.16.1"
      },
      {
        "model": "simatic hmi ktp mobile panels",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "sinema server",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "14.0"
      },
      {
        "model": "scalance s612",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1"
      },
      {
        "model": "simatic s7-1200 cpu 1212c",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "santricity smi-s provider",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "netapp",
        "version": null
      },
      {
        "model": "quantum security management",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "checkpoint",
        "version": "r81"
      },
      {
        "model": "scalance xr528-6m",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "6.4"
      },
      {
        "model": "tia administrator",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "sinec nms",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "1.0"
      },
      {
        "model": "simatic logon",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "1.5"
      },
      {
        "model": "freebsd",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "freebsd",
        "version": "12.2"
      },
      {
        "model": "sinumerik opc ua server",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "mysql server",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "oracle",
        "version": "8.0.23"
      },
      {
        "model": "ontap select deploy administration utility",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "netapp",
        "version": null
      },
      {
        "model": "scalance xb-200",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.3"
      },
      {
        "model": "scalance s602",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.1"
      },
      {
        "model": "ruggedcom rcm1224",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "6.2"
      },
      {
        "model": "node.js",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "nodejs",
        "version": "10.12.0"
      },
      {
        "model": "node.js",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "nodejs",
        "version": "12.13.0"
      },
      {
        "model": "simatic cp 1242-7 gprs v2",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "3.1"
      },
      {
        "model": "web gateway",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "mcafee",
        "version": "8.2.19"
      },
      {
        "model": "quantum security gateway",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "checkpoint",
        "version": "r80.40"
      },
      {
        "model": "simatic net cp 1545-1",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "1.0"
      },
      {
        "model": "simatic cloud connect 7",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "1.1"
      },
      {
        "model": "node.js",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "nodejs",
        "version": "15.0.0"
      },
      {
        "model": "simatic net cp 1243-8 irc",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "3.1"
      },
      {
        "model": "scalance w1700",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.0"
      },
      {
        "model": "node.js",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "nodejs",
        "version": "14.15.0"
      },
      {
        "model": "simatic net cp 1543-1",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.2"
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2021-3449"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Red Hat",
    "sources": [
      {
        "db": "PACKETSTORM",
        "id": "162699"
      },
      {
        "db": "PACKETSTORM",
        "id": "163209"
      },
      {
        "db": "PACKETSTORM",
        "id": "162383"
      },
      {
        "db": "PACKETSTORM",
        "id": "162183"
      },
      {
        "db": "PACKETSTORM",
        "id": "162307"
      },
      {
        "db": "PACKETSTORM",
        "id": "162337"
      },
      {
        "db": "PACKETSTORM",
        "id": "162197"
      }
    ],
    "trust": 0.7
  },
  "cve": "CVE-2021-3449",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "PARTIAL",
            "baseScore": 4.3,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 8.6,
            "id": "CVE-2021-3449",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 1.1,
            "vectorString": "AV:N/AC:M/Au:N/C:N/I:N/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "PARTIAL",
            "baseScore": 4.3,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 8.6,
            "id": "VHN-388130",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 0.1,
            "vectorString": "AV:N/AC:M/AU:N/C:N/I:N/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 5.9,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 2.2,
            "id": "CVE-2021-3449",
            "impactScore": 3.6,
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2021-3449",
            "trust": 1.0,
            "value": "MEDIUM"
          },
          {
            "author": "VULHUB",
            "id": "VHN-388130",
            "trust": 0.1,
            "value": "MEDIUM"
          },
          {
            "author": "VULMON",
            "id": "CVE-2021-3449",
            "trust": 0.1,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-388130"
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-3449"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-3449"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "An OpenSSL TLS server may crash if sent a maliciously crafted renegotiation ClientHello message from a client. If a TLSv1.2 renegotiation ClientHello omits the signature_algorithms extension (where it was present in the initial ClientHello), but includes a signature_algorithms_cert extension then a NULL pointer dereference will result, leading to a crash and a denial of service attack. A server is only vulnerable if it has TLSv1.2 and renegotiation enabled (which is the default configuration). OpenSSL TLS clients are not impacted by this issue. All OpenSSL 1.1.1 versions are affected by this issue. Users of these versions should upgrade to OpenSSL 1.1.1k. OpenSSL 1.0.2 is not impacted by this issue. Fixed in OpenSSL 1.1.1k (Affected 1.1.1-1.1.1j). The product supports a variety of encryption algorithms, including symmetric ciphers, hash algorithms, secure hash algorithms, etc. On March 25, 2021, the OpenSSL Project released a security advisory, OpenSSL Security Advisory [25 March 2021], that disclosed two vulnerabilities. \nExploitation of these vulnerabilities could allow an malicious user to use a valid non-certificate authority (CA) certificate to act as a CA and sign a certificate for an arbitrary organization, user or device, or to cause a denial of service (DoS) condition. \nThis advisory is available at the following link:tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-openssl-2021-GHY28dJd. \n\nBug Fix(es):\n\nThis update includes various bug fixes and enhancements. Space precludes\ndocumenting all of these changes in this advisory. Bugs fixed (https://bugzilla.redhat.com/):\n\n1803849 - [RFE] Include per volume encryption with Vault integration in RHCS 4.1\n1814681 - [RFE] use topologySpreadConstraints to evenly spread OSDs across hosts\n1840004 - CVE-2020-7608 nodejs-yargs-parser: prototype pollution vulnerability\n1850089 - OBC CRD is outdated and leads to missing columns in get queries\n1860594 - Toolbox pod should have toleration for OCS tainted nodes\n1861104 - OCS podDisruptionBudget prevents successful OCP upgrades\n1861878 - [RFE] use appropriate PDB values for OSD\n1866301 - [RHOCS Usability Study][Installation] \u201cCreate storage cluster\u201d should be a part of the installation flow or need to be emphasized as a crucial step. \n1869406 - must-gather should include historical pod logs\n1872730 - [RFE][External mode] Re-configure noobaa to use the updated RGW endpoint from the RHCS cluster\n1874367 - \"Create Backing Store\" page doesn\u0027t allow to select already defined k8s secret as target bucket credentials when Google Cloud Storage is selected as a provider\n1883371 - CVE-2020-26160 jwt-go: access restriction bypass vulnerability\n1886112 - log message flood with Reconciling StorageCluster\",\"Request.Namespace\":\"openshift-storage\",\"Request.Name\":\"ocs-storagecluster\"\n1886416 - Uninstall 4.6: ocs-operator logging regarding noobaa-core PVC needs change\n1886638 - CVE-2020-8565 kubernetes: Incomplete fix for CVE-2019-11250 allows for token leak in logs when logLevel \u003e= 9\n1888839 - Create public route for ceph-rgw service\n1892622 - [GSS] Noobaa management dashboard reporting High number of issues when the cluster is in healthy state\n1893611 - Skip ceph commands collection attempt if must-gather helper pod is not created\n1893613 - must-gather tries to collect ceph commands in external mode when storagecluster already deleted\n1893619 - OCS must-gather: Inspect errors for cephobjectoreUser and few ceph commandd when storage cluster does not exist\n1894412 - [RFE][External] RGW metrics should be made available even if anything else except 9283 is provided as the monitoring-endpoint-port\n1896338 - OCS upgrade from 4.6 to 4.7 build failed\n1897246 - OCS - ceph historical logs collection\n1897635 - CVE-2020-28362 golang: math/big: panic during recursive division of very large numbers\n1898509 - [Tracker][RHV #1899565] Deployment on RHV/oVirt storage class ovirt-csi-sc failing\n1898680 - CVE-2020-7774 nodejs-y18n: prototype pollution vulnerability\n1898808 - Rook-Ceph crash collector pod should not run on non-ocs node\n1900711 - [RFE] Alerting for Namespace buckets and resources\n1900722 - Failed to init upgrade process on noobaa-core-0\n1900749 - Namespace Resource reported as Healthy when target bucket deleted\n1900760 - RPC call for Namespace resource creation allows invalid target bucket names\n1901134 - OCS - ceph historical logs collection\n1902192 - [RFE][External] RGW metrics should be made available even if anything else except 9283 is provided as the monitoring-endpoint-port\n1902685 - Too strict Content-Length header check refuses valid upload requests\n1902711 - Tracker for Bug #1903078 Deleting VolumeSnapshotClass makes VolumeSnapshot not Ready\n1903973 - [Azure][ROKS] Set SSD tuning (tuneFastDeviceClass) as default for OSD devices in Azure/ROKS platform\n1903975 - Add \"ceph df detail\" for ocs must-gather to enable support to debug compression\n1904302 - [GSS] ceph_daemon label includes references to a replaced OSD that cause a prometheus ruleset to fail\n1904929 - [GSS][RFE]Reduce debug level for logs of Nooba Endpoint pod\n1907318 - Unable to deploy \u0026 upgrade to ocs 4.7 - missing postgres image reference\n1908414 - [GSS][VMWare][ROKS] rgw pods are not showing up in OCS 4.5 - due to pg_limit issue\n1908678 - ocs-osd-removal job failed with \"Invalid value\" error when using multiple ids\n1909268 - OCS 4.7 UI install -All OCS operator pods respin after storagecluster creation\n1909488 - [NooBaa CLI] CLI status command looks for wrong DB PV name\n1909745 - pv-pool backing store name restriction should be at 43 characters\n1910705 - OBCs are stuck in a Pending state\n1911131 - Bucket stats in the NB dashboard are incorrect\n1911266 - Backingstore phase is ready, modecode is INITIALIZING\n1911627 - CVE-2020-26289 nodejs-date-and-time: ReDoS in parsing via date.compile\n1911789 - Data deduplication does not work properly\n1912421 - [RFE] noobaa cli allow the creation of BackingStores with already existing secrets\n1912894 - OCS storagecluster is Progressing state and some noobaa pods missing with latest 4.7 build -4.7.0-223.ci and storagecluster reflected as 4.8.0 instead of 4.7.0\n1913149 - make must-gather backward compatibility for version \u003c4.6\n1913357 - ocs-operator should show error when flexible scaling and arbiter are both enabled at the same time\n1914132 - No metrics available in the Object Service Dashboard in OCS 4.7, logs show \"failed to retrieve metrics exporter servicemonitor\"\n1914159 - When OCS was deployed using arbiter mode mon\u0027s are going into CLBO state, ceph version = 14.2.11-95\n1914215 - must-gather fails to delete the completed state compute-xx-debug pods after successful completion\n1915111 - OCS OSD selection algorithm is making some strange choices. \n1915261 - Deleted MCG CRs are stuck in a \u0027Deleting\u0027 state\n1915445 - Uninstall 4.7: Storagecluster deletion stuck on a partially created KMS enabled OCS cluster + support TLS configuration for KMS\n1915644 - update noobaa db label in must-gather to collect db pod in noobaa dir\n1915698 - There is missing noobaa-core-0 pod after upgrade from OCS 4.6 to OCS 4.7\n1915706 - [Azure][RBD] PV taking longer time ~ 9 minutes to get deleted\n1915730 - [ocs-operator] Create public route for ceph-rgw service\n1915737 - Improve ocs-operator logging during uninstall to be more verbose, to understand reasons for failures - e.g. for Bug 1915445\n1915758 - improve noobaa logging in case of uninstall - logs do not specify clearly the resource on which deletion is stuck\n1915807 - Arbiter: OCS Install failed when used label = topology.kubernetes.io/zone instead of deprecated failureDomain label\n1915851 - OCS PodDisruptionBudget redesign for OSDs to allow multiple nodes to drain in the same failure domain\n1915953 - Must-gather takes hours to complete if the OCS cluster is not fully deployed, delay seen in ceph command collection step\n1916850 - Uninstall 4.7- rook: Storagecluster deletion stuck on a partially created KMS enabled OCS cluster(OSD creation failed)\n1917253 - Restore-pvc creation fails with error \"csi-vol-* has unsupported quota\"\n1917815 - [IBM Z and Power] OSD pods restarting due to OOM during upgrade test using ocs-ci\n1918360 - collect timestamp for must-gather commands and also the total time taken for must-gather to complete\n1918750 - CVE-2021-3114 golang: crypto/elliptic: incorrect operations on the P-224 curve\n1918925 - noobaa operator pod logs messages for other components - like rook-ceph-mon, csi-pods, new Storageclass, etc\n1918938 - ocs-operator has Error logs with \"unable to deploy Prometheus rules\"\n1919967 - MCG RPC calls time out and the system is unresponsive\n1920202 - RGW pod did not get created when OCS was deployed using arbiter mode\n1920498 - [IBM Z] OSDs are OOM killed  and storage cluster goes into error state during ocs-ci tier1 pvc expansion tests\n1920507 - Creation of cephblockpool with compression failed on timeout\n1921521 - Add support for VAULT_SKIP_VERIFY option in Ceph-CSI\n1921540 - RBD PVC creation fails with error \"invalid encryption kms configuration: \"POD_NAMESPACE\" is not set\"\n1921609 - MongoNetworkError messages in noobaa-core logs\n1921625 - \u0027Not Found: Secret \"noobaa-root-master-key\" message\u0027 in noobaa logs and cli output when kms is configured\n1922064 - uninstall on VMware LSO+ arbiter with 4 OSDs in Pending state: Storagecluster deletion stuck, waiting for cephcluster to be deleted\n1922108 - OCS 4.7 4.7.0-242.ci and beyond: osd pods are not created\n1922113 - noobaa-db pod init container is crashing after OCS upgrade from OCS 4.6 to OCS 4.7\n1922119 - PVC snapshot creation failing on OCP4.6-OCS 4.7 cluster\n1922421 - [ROKS] OCS deployment stuck at mon pod in pending state\n1922954 - [IBM Z] OCS: Failed tests because of osd deviceset restarts\n1924185 - Object Service Dashboard shows alerts related to \"system-internal-storage-pool\" in OCS 4.7\n1924211 - 4.7.0-249.ci: RGW pod not deployed, rook logs show - failed to create object store \"must be no more than 63 characters\"\n1924634 - MG terminal logs show `pods \"compute-x-debug\" not found` even though pods are in Running state\n1924784 - RBD PVC creation fails with error \"invalid encryption kms configuration: failed to parse kms configuration\"\n1924792 - RBD PVC creation fails with error \"invalid encryption kms configuration: failed to parse kms configuration\"\n1925055 - OSD pod stuck in Init:CrashLoopBackOff following Node maintenance in OCP upgrade from OCP 4.7 to 4.7 nightly\n1925179 - MG fix [continuation from bug 1893619]: Do not attempt creating helper pod if storagecluster/cephcluster already deleted\n1925249 - KMS resources should be garbage collected when StorageCluster is deleted\n1925533 - [GSS] Unable to install Noobaa in AWS govcloud\n1926182 - [RFE] Support disabling reconciliation of monitoring related resources using a dedicated reconcile strategy flag\n1926617 - osds are in Init:CrashLoopBackOff with rgw in CrashLoopBackOff on KMS enabled cluster\n1926717 - Only one NOOBAA_ROOT_SECRET_PATH key created in vault when the same backend path is used for multiple OCS clusters\n1926831 - [IBM][ROKS] Deploy RGW pods only if IBM COS is not available on platform\n1927128 - [Tracker for BZ #1937088] When Performed add capacity over arbiter mode cluster ceph health reports PG_AVAILABILITY Reduced data availability: 25 pgs inactive, 25 pgs incomplete\n1927138 - must-gather skip collection of ceph in every run\n1927186 - Configure pv-pool as backing store if cos creds secret not found in IBM Cloud\n1927317 - [Arbiter] Storage Cluster installation did not started because ocs-operator was Expecting 8 node found 4\n1927330 - Namespacestore-backed OBCs are stuck on Pending\n1927338 - Uninstall OCS: Include events for major CRs to know the cause of deletion getting stuck\n1927885 - OCS 4.7: ocs operator pod in 1/1 state even when Storagecluster is in Progressing state\n1928063 - For FD: rack: actual osd pod distribution and OSD placement in rack under ceph osd tree output do not match\n1928451 - MCG CLI command of diagnose doesn\u0027t work on windows\n1928471 - [Deployment blocker] Ceph OSDs do not register properly in the CRUSH map\n1928487 - MCG CLI - noobaa ui command shows wss instead of https\n1928642 - [IBM Z] rook-ceph-rgw pods restarts continously with ocs version 4.6.3 due to liveness probe failure\n1931191 - Backing/namespacestores are stuck on Creating with credentials errors\n1931810 - LSO deployment(flexibleScaling:true): 100% PGS unknown even though ceph osd tree placement is correct(root cause diff from bug 1928471)\n1931839 - OSD in state init:CrashLoopBackOff with KMS signed certificates\n1932400 - Namespacestore deletion takes 15 minutes\n1933607 - Prevent reconcile of labels on all monitoring resources deployed by ocs-operator\n1933609 - Prevent reconcile of labels on all monitoring resources deployed by rook\n1933736 - Allow shrinking the cluster by removing OSDs\n1934000 - Improve error logging for kv-v2 while using encryption with KMS\n1934990 - Ceph health ERR post node drain on KMS encryption enabled cluster\n1935342 - [RFE] Add OSD flapping alert\n1936545 - [Tracker for BZ #1938669] setuid and setgid file bits are not retained after a OCS CephFS CSI restore\n1936877 - Include at OCS Multi-Cloud Object Gateway core container image the fixes on CVEs from RHEL8 on \"nodejs\"\n1937070 - Storage cluster cannot be uninstalled when cluster not fully configured\n1937100 - [RGW][notification][kafka]: notification fails with error: pubsub endpoint configuration error: unknown schema in: kafka\n1937245 - csi-cephfsplugin pods CrashLoopBackoff in fresh 4.6 cluster due to conflict with kube-rbac-proxy\n1937768 - OBC with Cache BucketPolicy stuck on pending\n1939026 - ServiceUnavailable when calling the CreateBucket operation (reached max retries: 4): Reduce your request rate\n1939472 - Failure domain set incorrectly to zone if flexible scaling is enabled but there are \u003e= 3 zones\n1939617 - [Arbiter] Mons cannot be failed over in stretch mode\n1940440 - noobaa migration pod is deleted on failure and logs are not available for inspection\n1940476 - Backingstore deletion hangs\n1940957 - Deletion of Rejected NamespaceStore is stuck even when target bucket and bucketclass are deleted\n1941647 - OCS deployment fails when no backend path is specified for cluster wide encryption using KMS\n1941977 - rook-ceph-osd-X gets stuck in initcontainer expand-encrypted-bluefs\n1942344 - No permissions in /etc/passwd leads to fail noobaa-operaor\n1942350 - No permissions in /etc/passwd leads to fail noobaa-operaor\n1942519 - MCG should not use KMS to store encryption keys if cluster wide encryption is not enabled using KMS\n1943275 - OSD pods re-spun after \"add capacity\" on cluster with KMS\n1943596 - [Tracker for BZ #1944611][Arbiter] When Performed zone(zone=a) Power off and Power On, 3 mon pod(zone=b,c) goes in CLBO after node Power off and 2 Osd(zone=a) goes in CLBO after node Power on\n1944980 - Noobaa deployment fails when no KMS backend path is provided during storagecluster creation\n1946592 - [Arbiter] When both the rgw pod hosting nodes are down, the rgw service is unavailable\n1946837 - OCS 4.7 Arbiter Mode Cluster becomes stuck when entire zone is shutdown\n1955328 - Upgrade of noobaa DB failed when upgrading OCS 4.6 to 4.7\n1955601 - CVE-2021-3528 NooBaa: noobaa-operator leaking RPC AuthToken into log files\n1957187 - Update to RHCS 4.2z1 Ceph container image at OCS 4.7.0\n1957639 - Noobaa migrate job is failing when upgrading OCS 4.6.4 to 4.7 on FIPS environment\n\n5. -----BEGIN PGP SIGNED MESSAGE-----\nHash: SHA256\n\n====================================================================                   \nRed Hat Security Advisory\n\nSynopsis:          Moderate: Red Hat OpenShift Container Storage 4.6.5 security and bug fix update\nAdvisory ID:       RHSA-2021:2479-01\nProduct:           Red Hat OpenShift Container Storage\nAdvisory URL:      https://access.redhat.com/errata/RHSA-2021:2479\nIssue date:        2021-06-17\nCVE Names:         CVE-2016-10228 CVE-2017-14502 CVE-2019-2708\n                   CVE-2019-3842 CVE-2019-9169 CVE-2019-13012\n                   CVE-2019-14866 CVE-2019-25013 CVE-2020-8231\n                   CVE-2020-8284 CVE-2020-8285 CVE-2020-8286\n                   CVE-2020-8927 CVE-2020-9948 CVE-2020-9951\n                   CVE-2020-9983 CVE-2020-13434 CVE-2020-13543\n                   CVE-2020-13584 CVE-2020-13776 CVE-2020-15358\n                   CVE-2020-24977 CVE-2020-25659 CVE-2020-25678\n                   CVE-2020-26116 CVE-2020-26137 CVE-2020-27618\n                   CVE-2020-27619 CVE-2020-27783 CVE-2020-28196\n                   CVE-2020-29361 CVE-2020-29362 CVE-2020-29363\n                   CVE-2020-36242 CVE-2021-3139 CVE-2021-3177\n                   CVE-2021-3326 CVE-2021-3449 CVE-2021-3450\n                   CVE-2021-3528 CVE-2021-20305 CVE-2021-23239\n                   CVE-2021-23240 CVE-2021-23336\n====================================================================\n1. Summary:\n\nUpdated images that fix one security issue and several bugs are now\navailable for Red Hat OpenShift Container Storage 4.6.5 on Red Hat\nEnterprise Linux 8 from Red Hat Container Registry. \n\nRed Hat Product Security has rated this update as having a security impact\nof Moderate. A Common Vulnerability Scoring System (CVSS) base score, which\ngives a detailed severity rating, is available for each vulnerability from\nthe CVE link(s) in the References section. \n\n2. Description:\n\nRed Hat OpenShift Container Storage is software-defined storage integrated\nwith and optimized for the Red Hat OpenShift Container Platform. Red Hat\nOpenShift Container Storage is a highly scalable, production-grade\npersistent storage for stateful applications running in the Red Hat\nOpenShift Container Platform. In addition to persistent storage, Red Hat\nOpenShift Container Storage provisions a multicloud data management service\nwith an S3 compatible API. \n\nSecurity Fix(es):\n\n* NooBaa: noobaa-operator leaking RPC AuthToken into log files\n(CVE-2021-3528)\n\nFor more details about the security issue(s), including the impact, a CVSS\nscore, and other related information, refer to the CVE page(s) listed in\nthe References section. \n\nBug Fix(es):\n\n* Currently, a newly restored PVC cannot be mounted if some of the\nOpenShift Container Platform nodes are running on a version of Red Hat\nEnterprise Linux which is less than 8.2, and the snapshot from which the\nPVC was restored is deleted. \nWorkaround: Do not delete the snapshot from which the PVC was restored\nuntil the restored PVC is deleted. (BZ#1962483)\n\n* Previously, the default backingstore was not created on AWS S3 when\nOpenShift Container Storage was deployed, due to incorrect identification\nof AWS S3. With this update, the default backingstore gets created when\nOpenShift Container Storage is deployed on AWS S3. (BZ#1927307)\n\n* Previously, log messages were printed to the endpoint pod log even if the\ndebug option was not set. With this update, the log messages are printed to\nthe endpoint pod log only when the debug option is set. (BZ#1938106)\n\n* Previously, the PVCs could not be provisioned as the `rook-ceph-mds` did\nnot register the pod IP on the monitor servers, and hence every mount on\nthe filesystem timed out, resulting in CephFS volume provisioning failure. \nWith this update, an argument `--public-addr=podIP` is added to the MDS pod\nwhen the host network is not enabled, and hence the CephFS volume\nprovisioning does not fail. (BZ#1949558)\n\n* Previously, OpenShift Container Storage 4.2 clusters were not updated\nwith the correct cache value, and hence MDSs in standby-replay might report\nan oversized cache, as rook did not apply the `mds_cache_memory_limit`\nargument during upgrades. With this update, the `mds_cache_memory_limit`\nargument is applied during upgrades and the mds daemon operates normally. \n(BZ#1951348)\n\n* Previously, the coredumps were not generated in the correct location as\nrook was setting the config option `log_file` to an empty string since\nlogging happened on stdout and not on the files, and hence Ceph read the\nvalue of the `log_file` to build the dump path. With this update, rook does\nnot set the `log_file` and keeps Ceph\u0027s internal default, and hence the\ncoredumps are generated in the correct location and are accessible under\n`/var/log/ceph/`. (BZ#1938049)\n\n* Previously, Ceph became inaccessible, as the mons lose quorum if a mon\npod was drained while another mon was failing over. With this update,\nvoluntary mon drains are prevented while a mon is failing over, and hence\nCeph does not become inaccessible. (BZ#1946573)\n\n* Previously, the mon quorum was at risk, as the operator could erroneously\nremove the new mon if the operator was restarted during a mon failover. \nWith this update, the operator completes the same mon failover after the\noperator is restarted, and hence the mon quorum is more reliable in the\nnode drains and mon failover scenarios. (BZ#1959983)\n\nAll users of Red Hat OpenShift Container Storage are advised to pull these\nnew images from the Red Hat Container Registry. \n\n3. Solution:\n\nBefore applying this update, make sure all previously released errata\nrelevant to your system have been applied. \n\nFor details on how to apply this update, refer to:\n\nhttps://access.redhat.com/articles/11258\n\n4. Bugs fixed (https://bugzilla.redhat.com/):\n\n1938106 - [GSS][RFE]Reduce debug level for logs of Nooba Endpoint pod\n1950915 - XSS Vulnerability with Noobaa version 5.5.0-3bacc6b\n1951348 - [GSS][CephFS] health warning \"MDS cache is too large (3GB/1GB); 0 inodes in use by clients, 0 stray files\" for the standby-replay\n1951600 - [4.6.z][Clone of BZ #1936545] setuid and setgid file bits are not retained after a OCS CephFS CSI restore\n1955601 - CVE-2021-3528 NooBaa: noobaa-operator leaking RPC AuthToken into log files\n1957189 - [Rebase] Use RHCS4.2z1 container image with OCS 4..6.5[may require doc update for external mode min supported RHCS version]\n1959980 - When a node is being drained, increase the mon failover timeout to prevent unnecessary mon failover\n1959983 - [GSS][mon] rook-operator scales mons to 4 after healthCheck timeout\n1962483 - [RHEL7][RBD][4.6.z clone] FailedMount error when using restored PVC on app pod\n\n5. References:\n\nhttps://access.redhat.com/security/cve/CVE-2016-10228\nhttps://access.redhat.com/security/cve/CVE-2017-14502\nhttps://access.redhat.com/security/cve/CVE-2019-2708\nhttps://access.redhat.com/security/cve/CVE-2019-3842\nhttps://access.redhat.com/security/cve/CVE-2019-9169\nhttps://access.redhat.com/security/cve/CVE-2019-13012\nhttps://access.redhat.com/security/cve/CVE-2019-14866\nhttps://access.redhat.com/security/cve/CVE-2019-25013\nhttps://access.redhat.com/security/cve/CVE-2020-8231\nhttps://access.redhat.com/security/cve/CVE-2020-8284\nhttps://access.redhat.com/security/cve/CVE-2020-8285\nhttps://access.redhat.com/security/cve/CVE-2020-8286\nhttps://access.redhat.com/security/cve/CVE-2020-8927\nhttps://access.redhat.com/security/cve/CVE-2020-9948\nhttps://access.redhat.com/security/cve/CVE-2020-9951\nhttps://access.redhat.com/security/cve/CVE-2020-9983\nhttps://access.redhat.com/security/cve/CVE-2020-13434\nhttps://access.redhat.com/security/cve/CVE-2020-13543\nhttps://access.redhat.com/security/cve/CVE-2020-13584\nhttps://access.redhat.com/security/cve/CVE-2020-13776\nhttps://access.redhat.com/security/cve/CVE-2020-15358\nhttps://access.redhat.com/security/cve/CVE-2020-24977\nhttps://access.redhat.com/security/cve/CVE-2020-25659\nhttps://access.redhat.com/security/cve/CVE-2020-25678\nhttps://access.redhat.com/security/cve/CVE-2020-26116\nhttps://access.redhat.com/security/cve/CVE-2020-26137\nhttps://access.redhat.com/security/cve/CVE-2020-27618\nhttps://access.redhat.com/security/cve/CVE-2020-27619\nhttps://access.redhat.com/security/cve/CVE-2020-27783\nhttps://access.redhat.com/security/cve/CVE-2020-28196\nhttps://access.redhat.com/security/cve/CVE-2020-29361\nhttps://access.redhat.com/security/cve/CVE-2020-29362\nhttps://access.redhat.com/security/cve/CVE-2020-29363\nhttps://access.redhat.com/security/cve/CVE-2020-36242\nhttps://access.redhat.com/security/cve/CVE-2021-3139\nhttps://access.redhat.com/security/cve/CVE-2021-3177\nhttps://access.redhat.com/security/cve/CVE-2021-3326\nhttps://access.redhat.com/security/cve/CVE-2021-3449\nhttps://access.redhat.com/security/cve/CVE-2021-3450\nhttps://access.redhat.com/security/cve/CVE-2021-3528\nhttps://access.redhat.com/security/cve/CVE-2021-20305\nhttps://access.redhat.com/security/cve/CVE-2021-23239\nhttps://access.redhat.com/security/cve/CVE-2021-23240\nhttps://access.redhat.com/security/cve/CVE-2021-23336\nhttps://access.redhat.com/security/updates/classification/#moderate\n\n6. Contact:\n\nThe Red Hat security contact is \u003csecalert@redhat.com\u003e. More contact\ndetails at https://access.redhat.com/security/team/contact/\n\nCopyright 2021 Red Hat, Inc. \n-----BEGIN PGP SIGNATURE-----\nVersion: GnuPG v1\n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\nRCrstqAM5QQ=DHD0\n-----END PGP SIGNATURE-----\n\n--\nRHSA-announce mailing list\nRHSA-announce@redhat.com\nhttps://listman.redhat.com/mailman/listinfo/rhsa-announce\n. \n\nBug fix:\n\n* RHACM 2.0.10 images (BZ #1940452)\n\n3. Bugs fixed (https://bugzilla.redhat.com/):\n\n1940452 - RHACM 2.0.10 images\n1944286 - CVE-2021-23358 nodejs-underscore: Arbitrary code execution via the template function\n\n5. It is comprised of the Apache\nTomcat Servlet container, JBoss HTTP Connector (mod_cluster), the\nPicketLink Vault extension for Apache Tomcat, and the Tomcat Native\nlibrary. Bugs fixed (https://bugzilla.redhat.com/):\n\n1918750 - CVE-2021-3114 golang: crypto/elliptic: incorrect operations on the P-224 curve\n1918761 - CVE-2021-3115 golang: cmd/go: packages using cgo can cause arbitrary code execution at build time\n1935897 - Release of OpenShift Serverless Serving 1.14.0\n1935898 - Release of OpenShift Serverless Eventing 1.14.0\n\n5. - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -\nGentoo Linux Security Advisory                           GLSA 202103-03\n- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -\n                                            https://security.gentoo.org/\n- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -\n\n  Severity: Normal\n     Title: OpenSSL: Multiple vulnerabilities\n      Date: March 31, 2021\n      Bugs: #769785, #777681\n        ID: 202103-03\n\n- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -\n\nSynopsis\n========\n\nMultiple vulnerabilities have been found in OpenSSL, the worst of which\ncould allow remote attackers to cause a Denial of Service condition. \n\nBackground\n==========\n\nOpenSSL is an Open Source toolkit implementing the Secure Sockets Layer\n(SSL v2/v3) and Transport Layer Security (TLS v1/v1.1/v1.2/v1.3) as\nwell as a general purpose cryptography library. \n\nAffected packages\n=================\n\n     -------------------------------------------------------------------\n      Package              /     Vulnerable     /            Unaffected\n     -------------------------------------------------------------------\n   1  dev-libs/openssl             \u003c 1.1.1k                  \u003e= 1.1.1k\n\nDescription\n===========\n\nMultiple vulnerabilities have been discovered in OpenSSL. Please review\nthe CVE identifiers referenced below for details. \n\nImpact\n======\n\nPlease review the referenced CVE identifiers for details. \n\nWorkaround\n==========\n\nThere is no known workaround at this time. \n\nResolution\n==========\n\nAll OpenSSL users should upgrade to the latest version:\n\n   # emerge --sync\n   # emerge --ask --oneshot --verbose \"\u003e=dev-libs/openssl-1.1.1k\"\n\nReferences\n==========\n\n[ 1 ] CVE-2021-23840\n       https://nvd.nist.gov/vuln/detail/CVE-2021-23840\n[ 2 ] CVE-2021-23841\n       https://nvd.nist.gov/vuln/detail/CVE-2021-23841\n[ 3 ] CVE-2021-3449\n       https://nvd.nist.gov/vuln/detail/CVE-2021-3449\n[ 4 ] CVE-2021-3450\n       https://nvd.nist.gov/vuln/detail/CVE-2021-3450\n\nAvailability\n============\n\nThis GLSA and any updates to it are available for viewing at\nthe Gentoo Security Website:\n\n  https://security.gentoo.org/glsa/202103-03\n\nConcerns?\n=========\n\nSecurity is a primary focus of Gentoo Linux and ensuring the\nconfidentiality and security of our users\u0027 machines is of utmost\nimportance to us. Any security concerns should be addressed to\nsecurity@gentoo.org or alternatively, you may file a bug at\nhttps://bugs.gentoo.org. \n\nLicense\n=======\n\nCopyright 2021 Gentoo Foundation, Inc; referenced text\nbelongs to its owner(s). \n\nThe contents of this document are licensed under the\nCreative Commons - Attribution / Share Alike license. \n\nhttps://creativecommons.org/licenses/by-sa/2.5\n. Description:\n\nRed Hat Advanced Cluster Management for Kubernetes 2.1.6 images\n\nRed Hat Advanced Cluster Management for Kubernetes provides the\ncapabilities to address common challenges that administrators and site\nreliability engineers face as they work across a range of public and\nprivate cloud environments. Clusters and applications are all visible and\nmanaged from a single console\u2014with security policy built in. \n\nBug fixes:\n\n* RHACM 2.1.6 images (BZ#1940581)\n\n* When generating the import cluster string, it can include unescaped\ncharacters (BZ#1934184)\n\n3. Bugs fixed (https://bugzilla.redhat.com/):\n\n1853652 - CVE-2020-14040 golang.org/x/text: possibility to trigger an infinite loop in encoding/unicode could lead to crash\n1929338 - CVE-2020-35149 mquery: Code injection via merge or clone operation\n1934184 - When generating the import cluster string, it can include unescaped characters\n1940581 - RHACM 2.1.6 images\n\n5. Summary:\n\nRed Hat JBoss Core Services Pack Apache Server 2.4.37 Service Pack 7 zip\nrelease for RHEL 7, RHEL 8 and Microsoft Windows is available. This software, such as Apache HTTP Server, is\ncommon to multiple JBoss middleware products, and is packaged under Red Hat\nJBoss Core Services to allow for faster distribution of updates, and for a\nmore consistent update experience. \n\nThis release adds the new Apache HTTP Server 2.4.37 Service Pack 7 packages\nthat are part of the JBoss Core Services offering. Solution:\n\nBefore applying the update, back up your existing installation, including\nall applications, configuration files, databases and database settings, and\nso on. \n\nThe References section of this erratum contains a download link for the\nupdate. You must be logged in to download the update. Bugs fixed (https://bugzilla.redhat.com/):\n\n1941547 - CVE-2021-3450 openssl: CA certificate check bypass with X509_V_FLAG_X509_STRICT\n1941554 - CVE-2021-3449 openssl: NULL pointer dereference in signature_algorithms processing\n\n5. ==========================================================================\nUbuntu Security Notice USN-5038-1\nAugust 12, 2021\n\npostgresql-10, postgresql-12, postgresql-13 vulnerabilities\n==========================================================================\n\nA security issue affects these releases of Ubuntu and its derivatives:\n\n- Ubuntu 21.04\n- Ubuntu 20.04 LTS\n- Ubuntu 18.04 LTS\n\nSummary:\n\nSeveral security issues were fixed in PostgreSQL. \n\nSoftware Description:\n- postgresql-13: Object-relational SQL database\n- postgresql-12: Object-relational SQL database\n- postgresql-10: Object-relational SQL database\n\nDetails:\n\nIt was discovered that the PostgresQL planner could create incorrect plans\nin certain circumstances. A remote attacker could use this issue to cause\nPostgreSQL to crash, resulting in a denial of service, or possibly obtain\nsensitive information from memory. (CVE-2021-3677)\n\nIt was discovered that PostgreSQL incorrectly handled certain SSL\nrenegotiation ClientHello messages from clients. A remote attacker could\npossibly use this issue to cause PostgreSQL to crash, resulting in a denial\nof service. (CVE-2021-3449)\n\nUpdate instructions:\n\nThe problem can be corrected by updating your system to the following\npackage versions:\n\nUbuntu 21.04:\n  postgresql-13                   13.4-0ubuntu0.21.04.1\n\nUbuntu 20.04 LTS:\n  postgresql-12                   12.8-0ubuntu0.20.04.1\n\nUbuntu 18.04 LTS:\n  postgresql-10                   10.18-0ubuntu0.18.04.1\n\nThis update uses a new upstream release, which includes additional bug\nfixes. After a standard system update you need to restart PostgreSQL to\nmake all the necessary changes",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2021-3449"
      },
      {
        "db": "VULHUB",
        "id": "VHN-388130"
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-3449"
      },
      {
        "db": "PACKETSTORM",
        "id": "162699"
      },
      {
        "db": "PACKETSTORM",
        "id": "163209"
      },
      {
        "db": "PACKETSTORM",
        "id": "162383"
      },
      {
        "db": "PACKETSTORM",
        "id": "162183"
      },
      {
        "db": "PACKETSTORM",
        "id": "162307"
      },
      {
        "db": "PACKETSTORM",
        "id": "162041"
      },
      {
        "db": "PACKETSTORM",
        "id": "162337"
      },
      {
        "db": "PACKETSTORM",
        "id": "162197"
      },
      {
        "db": "PACKETSTORM",
        "id": "163815"
      }
    ],
    "trust": 1.89
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2021-3449",
        "trust": 2.1
      },
      {
        "db": "TENABLE",
        "id": "TNS-2021-06",
        "trust": 1.2
      },
      {
        "db": "TENABLE",
        "id": "TNS-2021-09",
        "trust": 1.2
      },
      {
        "db": "TENABLE",
        "id": "TNS-2021-05",
        "trust": 1.2
      },
      {
        "db": "TENABLE",
        "id": "TNS-2021-10",
        "trust": 1.2
      },
      {
        "db": "OPENWALL",
        "id": "OSS-SECURITY/2021/03/28/3",
        "trust": 1.2
      },
      {
        "db": "OPENWALL",
        "id": "OSS-SECURITY/2021/03/27/2",
        "trust": 1.2
      },
      {
        "db": "OPENWALL",
        "id": "OSS-SECURITY/2021/03/28/4",
        "trust": 1.2
      },
      {
        "db": "OPENWALL",
        "id": "OSS-SECURITY/2021/03/27/1",
        "trust": 1.2
      },
      {
        "db": "SIEMENS",
        "id": "SSA-772220",
        "trust": 1.2
      },
      {
        "db": "SIEMENS",
        "id": "SSA-389290",
        "trust": 1.2
      },
      {
        "db": "PULSESECURE",
        "id": "SA44845",
        "trust": 1.2
      },
      {
        "db": "MCAFEE",
        "id": "SB10356",
        "trust": 1.2
      },
      {
        "db": "PACKETSTORM",
        "id": "162197",
        "trust": 0.2
      },
      {
        "db": "PACKETSTORM",
        "id": "162041",
        "trust": 0.2
      },
      {
        "db": "PACKETSTORM",
        "id": "162183",
        "trust": 0.2
      },
      {
        "db": "PACKETSTORM",
        "id": "162383",
        "trust": 0.2
      },
      {
        "db": "PACKETSTORM",
        "id": "162699",
        "trust": 0.2
      },
      {
        "db": "PACKETSTORM",
        "id": "162337",
        "trust": 0.2
      },
      {
        "db": "PACKETSTORM",
        "id": "162307",
        "trust": 0.2
      },
      {
        "db": "PACKETSTORM",
        "id": "162114",
        "trust": 0.1
      },
      {
        "db": "PACKETSTORM",
        "id": "162076",
        "trust": 0.1
      },
      {
        "db": "PACKETSTORM",
        "id": "163257",
        "trust": 0.1
      },
      {
        "db": "PACKETSTORM",
        "id": "162350",
        "trust": 0.1
      },
      {
        "db": "PACKETSTORM",
        "id": "162013",
        "trust": 0.1
      },
      {
        "db": "PACKETSTORM",
        "id": "162151",
        "trust": 0.1
      },
      {
        "db": "PACKETSTORM",
        "id": "162189",
        "trust": 0.1
      },
      {
        "db": "PACKETSTORM",
        "id": "162196",
        "trust": 0.1
      },
      {
        "db": "PACKETSTORM",
        "id": "162172",
        "trust": 0.1
      },
      {
        "db": "PACKETSTORM",
        "id": "161984",
        "trust": 0.1
      },
      {
        "db": "PACKETSTORM",
        "id": "162201",
        "trust": 0.1
      },
      {
        "db": "PACKETSTORM",
        "id": "162200",
        "trust": 0.1
      },
      {
        "db": "SEEBUG",
        "id": "SSVID-99170",
        "trust": 0.1
      },
      {
        "db": "VULHUB",
        "id": "VHN-388130",
        "trust": 0.1
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-22-104-05",
        "trust": 0.1
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-3449",
        "trust": 0.1
      },
      {
        "db": "PACKETSTORM",
        "id": "163209",
        "trust": 0.1
      },
      {
        "db": "PACKETSTORM",
        "id": "163815",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-388130"
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-3449"
      },
      {
        "db": "PACKETSTORM",
        "id": "162699"
      },
      {
        "db": "PACKETSTORM",
        "id": "163209"
      },
      {
        "db": "PACKETSTORM",
        "id": "162383"
      },
      {
        "db": "PACKETSTORM",
        "id": "162183"
      },
      {
        "db": "PACKETSTORM",
        "id": "162307"
      },
      {
        "db": "PACKETSTORM",
        "id": "162041"
      },
      {
        "db": "PACKETSTORM",
        "id": "162337"
      },
      {
        "db": "PACKETSTORM",
        "id": "162197"
      },
      {
        "db": "PACKETSTORM",
        "id": "163815"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-3449"
      }
    ]
  },
  "id": "VAR-202103-1464",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-388130"
      }
    ],
    "trust": 0.6962928186666667
  },
  "last_update_date": "2025-12-22T21:36:21.482000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Debian Security Advisories: DSA-4875-1 openssl -- security update",
        "trust": 0.1,
        "url": "https://vulmon.com/vendoradvisory?qidtp=debian_security_advisories\u0026qid=b5207bd1e788bc6e8d94f410cf4801bc"
      },
      {
        "title": "Red Hat: CVE-2021-3449",
        "trust": 0.1,
        "url": "https://vulmon.com/vendoradvisory?qidtp=red_hat_cve_database\u0026qid=CVE-2021-3449"
      },
      {
        "title": "Amazon Linux 2: ALAS2-2021-1622",
        "trust": 0.1,
        "url": "https://vulmon.com/vendoradvisory?qidtp=amazon_linux2\u0026qid=ALAS2-2021-1622"
      },
      {
        "title": "Arch Linux Issues: ",
        "trust": 0.1,
        "url": "https://vulmon.com/vendoradvisory?qidtp=arch_linux_issues\u0026qid=CVE-2021-3449 log"
      },
      {
        "title": "Cisco: Multiple Vulnerabilities in OpenSSL Affecting Cisco Products: March 2021",
        "trust": 0.1,
        "url": "https://vulmon.com/vendoradvisory?qidtp=cisco_security_advisories_and_alerts_ciscoproducts\u0026qid=cisco-sa-openssl-2021-GHY28dJd"
      },
      {
        "title": "Hitachi Security Advisories: Vulnerability in JP1/Base and JP1/ File Transmission Server/FTP",
        "trust": 0.1,
        "url": "https://vulmon.com/vendoradvisory?qidtp=hitachi_security_advisories\u0026qid=hitachi-sec-2021-130"
      },
      {
        "title": "Tenable Security Advisories: [R1] Tenable.sc 5.18.0 Fixes One Third-party Vulnerability",
        "trust": 0.1,
        "url": "https://vulmon.com/vendoradvisory?qidtp=tenable_security_advisories\u0026qid=TNS-2021-06"
      },
      {
        "title": "Tenable Security Advisories: [R1] Nessus 8.13.2 Fixes Multiple Third-party Vulnerabilities",
        "trust": 0.1,
        "url": "https://vulmon.com/vendoradvisory?qidtp=tenable_security_advisories\u0026qid=TNS-2021-05"
      },
      {
        "title": "Hitachi Security Advisories: Multiple Vulnerabilities in Hitachi Ops Center Common Services",
        "trust": 0.1,
        "url": "https://vulmon.com/vendoradvisory?qidtp=hitachi_security_advisories\u0026qid=hitachi-sec-2021-117"
      },
      {
        "title": "Hitachi Security Advisories: Multiple Vulnerabilities in Hitachi Ops Center Analyzer viewpoint",
        "trust": 0.1,
        "url": "https://vulmon.com/vendoradvisory?qidtp=hitachi_security_advisories\u0026qid=hitachi-sec-2021-119"
      },
      {
        "title": "Tenable Security Advisories: [R1] Nessus Network Monitor 5.13.1 Fixes Multiple Third-party Vulnerabilities",
        "trust": 0.1,
        "url": "https://vulmon.com/vendoradvisory?qidtp=tenable_security_advisories\u0026qid=TNS-2021-09"
      },
      {
        "title": "Tenable Security Advisories: [R1] LCE 6.0.9 Fixes Multiple Third-party Vulnerabilities",
        "trust": 0.1,
        "url": "https://vulmon.com/vendoradvisory?qidtp=tenable_security_advisories\u0026qid=TNS-2021-10"
      },
      {
        "title": "Red Hat: Moderate: OpenShift Container Platform 4.10.3 security update",
        "trust": 0.1,
        "url": "https://vulmon.com/vendoradvisory?qidtp=red_hat_security_advisories\u0026qid=RHSA-20220056 - Security Advisory"
      },
      {
        "title": "CVE-2021-3449 OpenSSL \u003c1.1.1k DoS exploit",
        "trust": 0.1,
        "url": "https://github.com/terorie/cve-2021-3449 "
      },
      {
        "title": "CVE-2021-3449 OpenSSL \u003c1.1.1k DoS exploit",
        "trust": 0.1,
        "url": "https://github.com/gitchangye/cve "
      },
      {
        "title": "NSAPool-PenTest",
        "trust": 0.1,
        "url": "https://github.com/AliceMongodin/NSAPool-PenTest "
      },
      {
        "title": "Analysis of attack vectors for embedded Linux",
        "trust": 0.1,
        "url": "https://github.com/FeFi7/attacking_embedded_linux "
      },
      {
        "title": "openssl-cve",
        "trust": 0.1,
        "url": "https://github.com/yonhan3/openssl-cve "
      },
      {
        "title": "CVE-Check",
        "trust": 0.1,
        "url": "https://github.com/falk-werner/cve-check "
      },
      {
        "title": "SEEKER_dataset",
        "trust": 0.1,
        "url": "https://github.com/SF4bin/SEEKER_dataset "
      },
      {
        "title": "Year of the Jellyfish (YotJF)",
        "trust": 0.1,
        "url": "https://github.com/rnbochsr/yr_of_the_jellyfish "
      },
      {
        "title": "https://github.com/tianocore-docs/ThirdPartySecurityAdvisories",
        "trust": 0.1,
        "url": "https://github.com/tianocore-docs/ThirdPartySecurityAdvisories "
      },
      {
        "title": "TASSL-1.1.1k",
        "trust": 0.1,
        "url": "https://github.com/jntass/TASSL-1.1.1k "
      },
      {
        "title": "Trivy by Aqua security\nRefer this official repository for explore  Trivy Action",
        "trust": 0.1,
        "url": "https://github.com/scholarnishu/Trivy-by-AquaSecurity "
      },
      {
        "title": "Trivy by Aqua security\nRefer this official repository for explore  Trivy Action",
        "trust": 0.1,
        "url": "https://github.com/thecyberbaby/Trivy-by-aquaSecurity "
      },
      {
        "title": "\ud83d\udc31 Catlin Vulnerability Scanner \ud83d\udc31",
        "trust": 0.1,
        "url": "https://github.com/vinamra28/tekton-image-scan-trivy "
      },
      {
        "title": "DEVOPS + ACR + TRIVY",
        "trust": 0.1,
        "url": "https://github.com/arindam0310018/04-Apr-2022-DevOps__Scan-Images-In-ACR-Using-Trivy "
      },
      {
        "title": "Trivy Demo",
        "trust": 0.1,
        "url": "https://github.com/fredrkl/trivy-demo "
      },
      {
        "title": "GitHub Actions CI App Pipeline",
        "trust": 0.1,
        "url": "https://github.com/isgo-golgo13/gokit-gorillakit-enginesvc "
      },
      {
        "title": "Awesome Stars",
        "trust": 0.1,
        "url": "https://github.com/taielab/awesome-hacking-lists "
      },
      {
        "title": "podcast-dl-gael",
        "trust": 0.1,
        "url": "https://github.com/GitHubForSnap/podcast-dl-gael "
      },
      {
        "title": "sec-tools",
        "trust": 0.1,
        "url": "https://github.com/matengfei000/sec-tools "
      },
      {
        "title": "sec-tools",
        "trust": 0.1,
        "url": "https://github.com/anquanscan/sec-tools "
      },
      {
        "title": "\u66f4\u65b0\u4e8e 2023-11-27 08:36:01\n\u5b89\u5168\n\u5f00\u53d1\n\u672a\u5206\u7c7b\n\u6742\u4e03\u6742\u516b",
        "trust": 0.1,
        "url": "https://github.com/20142995/sectool "
      },
      {
        "title": "Vulnerability",
        "trust": 0.1,
        "url": "https://github.com/tzwlhack/Vulnerability "
      },
      {
        "title": "OpenSSL-CVE-lib",
        "trust": 0.1,
        "url": "https://github.com/chnzzh/OpenSSL-CVE-lib "
      },
      {
        "title": "PoC in GitHub",
        "trust": 0.1,
        "url": "https://github.com/soosmile/POC "
      },
      {
        "title": "PoC in GitHub",
        "trust": 0.1,
        "url": "https://github.com/manas3c/CVE-POC "
      },
      {
        "title": "The Register",
        "trust": 0.1,
        "url": "https://www.theregister.co.uk/2021/03/25/openssl_bug_fix/"
      }
    ],
    "sources": [
      {
        "db": "VULMON",
        "id": "CVE-2021-3449"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-476",
        "trust": 1.1
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-388130"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-3449"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.3,
        "url": "https://tools.cisco.com/security/center/content/ciscosecurityadvisory/cisco-sa-openssl-2021-ghy28djd"
      },
      {
        "trust": 1.3,
        "url": "https://www.debian.org/security/2021/dsa-4875"
      },
      {
        "trust": 1.3,
        "url": "https://security.gentoo.org/glsa/202103-03"
      },
      {
        "trust": 1.2,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-389290.pdf"
      },
      {
        "trust": 1.2,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-772220.pdf"
      },
      {
        "trust": 1.2,
        "url": "https://kb.pulsesecure.net/articles/pulse_security_advisories/sa44845"
      },
      {
        "trust": 1.2,
        "url": "https://psirt.global.sonicwall.com/vuln-detail/snwlid-2021-0013"
      },
      {
        "trust": 1.2,
        "url": "https://security.netapp.com/advisory/ntap-20210326-0006/"
      },
      {
        "trust": 1.2,
        "url": "https://security.netapp.com/advisory/ntap-20210513-0002/"
      },
      {
        "trust": 1.2,
        "url": "https://www.openssl.org/news/secadv/20210325.txt"
      },
      {
        "trust": 1.2,
        "url": "https://www.tenable.com/security/tns-2021-05"
      },
      {
        "trust": 1.2,
        "url": "https://www.tenable.com/security/tns-2021-06"
      },
      {
        "trust": 1.2,
        "url": "https://www.tenable.com/security/tns-2021-09"
      },
      {
        "trust": 1.2,
        "url": "https://www.tenable.com/security/tns-2021-10"
      },
      {
        "trust": 1.2,
        "url": "https://security.freebsd.org/advisories/freebsd-sa-21:07.openssl.asc"
      },
      {
        "trust": 1.2,
        "url": "https://www.oracle.com//security-alerts/cpujul2021.html"
      },
      {
        "trust": 1.2,
        "url": "https://www.oracle.com/security-alerts/cpuapr2021.html"
      },
      {
        "trust": 1.2,
        "url": "https://www.oracle.com/security-alerts/cpuapr2022.html"
      },
      {
        "trust": 1.2,
        "url": "https://www.oracle.com/security-alerts/cpujul2022.html"
      },
      {
        "trust": 1.2,
        "url": "https://www.oracle.com/security-alerts/cpuoct2021.html"
      },
      {
        "trust": 1.2,
        "url": "https://lists.debian.org/debian-lts-announce/2021/08/msg00029.html"
      },
      {
        "trust": 1.2,
        "url": "http://www.openwall.com/lists/oss-security/2021/03/27/1"
      },
      {
        "trust": 1.2,
        "url": "http://www.openwall.com/lists/oss-security/2021/03/27/2"
      },
      {
        "trust": 1.2,
        "url": "http://www.openwall.com/lists/oss-security/2021/03/28/3"
      },
      {
        "trust": 1.2,
        "url": "http://www.openwall.com/lists/oss-security/2021/03/28/4"
      },
      {
        "trust": 1.1,
        "url": "https://kc.mcafee.com/corporate/index?page=content\u0026id=sb10356"
      },
      {
        "trust": 1.1,
        "url": "https://git.openssl.org/gitweb/?p=openssl.git%3ba=commitdiff%3bh=fb9fa6b51defd48157eeb207f52181f735d96148"
      },
      {
        "trust": 1.1,
        "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/ccbfllvqvilivgzmbjl3ixzgkwqisynp/"
      },
      {
        "trust": 1.0,
        "url": "https://security.netapp.com/advisory/ntap-20240621-0006/"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2021-3449"
      },
      {
        "trust": 0.7,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2021-3450"
      },
      {
        "trust": 0.7,
        "url": "https://listman.redhat.com/mailman/listinfo/rhsa-announce"
      },
      {
        "trust": 0.7,
        "url": "https://access.redhat.com/security/team/contact/"
      },
      {
        "trust": 0.7,
        "url": "https://access.redhat.com/security/cve/cve-2021-3449"
      },
      {
        "trust": 0.7,
        "url": "https://access.redhat.com/security/cve/cve-2021-3450"
      },
      {
        "trust": 0.7,
        "url": "https://bugzilla.redhat.com/):"
      },
      {
        "trust": 0.5,
        "url": "https://access.redhat.com/security/cve/cve-2021-20305"
      },
      {
        "trust": 0.5,
        "url": "https://access.redhat.com/security/updates/classification/#moderate"
      },
      {
        "trust": 0.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2021-20305"
      },
      {
        "trust": 0.2,
        "url": "https://access.redhat.com/articles/11258"
      },
      {
        "trust": 0.2,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2020-25678"
      },
      {
        "trust": 0.2,
        "url": "https://access.redhat.com/security/cve/cve-2020-25678"
      },
      {
        "trust": 0.2,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2020-28362"
      },
      {
        "trust": 0.2,
        "url": "https://access.redhat.com/security/cve/cve-2021-3139"
      },
      {
        "trust": 0.2,
        "url": "https://access.redhat.com/security/cve/cve-2021-3114"
      },
      {
        "trust": 0.2,
        "url": "https://access.redhat.com/security/cve/cve-2020-28362"
      },
      {
        "trust": 0.2,
        "url": "https://access.redhat.com/security/cve/cve-2021-3528"
      },
      {
        "trust": 0.2,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2021-3114"
      },
      {
        "trust": 0.2,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2021-27363"
      },
      {
        "trust": 0.2,
        "url": "https://access.redhat.com/documentation/en-us/red_hat_advanced_cluster_mana"
      },
      {
        "trust": 0.2,
        "url": "https://access.redhat.com/security/cve/cve-2021-3347"
      },
      {
        "trust": 0.2,
        "url": "https://access.redhat.com/security/cve/cve-2020-28374"
      },
      {
        "trust": 0.2,
        "url": "https://access.redhat.com/security/cve/cve-2021-27364"
      },
      {
        "trust": 0.2,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2021-26708"
      },
      {
        "trust": 0.2,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2021-27365"
      },
      {
        "trust": 0.2,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2020-0466"
      },
      {
        "trust": 0.2,
        "url": "https://access.redhat.com/security/cve/cve-2020-27152"
      },
      {
        "trust": 0.2,
        "url": "https://access.redhat.com/security/cve/cve-2021-27363"
      },
      {
        "trust": 0.2,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2020-27152"
      },
      {
        "trust": 0.2,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2021-3347"
      },
      {
        "trust": 0.2,
        "url": "https://access.redhat.com/security/cve/cve-2021-27365"
      },
      {
        "trust": 0.2,
        "url": "https://access.redhat.com/security/cve/cve-2020-0466"
      },
      {
        "trust": 0.2,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2021-27364"
      },
      {
        "trust": 0.2,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2020-28374"
      },
      {
        "trust": 0.2,
        "url": "https://access.redhat.com/security/cve/cve-2021-26708"
      },
      {
        "trust": 0.2,
        "url": "https://access.redhat.com/security/updates/classification/#important"
      },
      {
        "trust": 0.1,
        "url": "https://git.openssl.org/gitweb/?p=openssl.git;a=commitdiff;h=fb9fa6b51defd48157eeb207f52181f735d96148"
      },
      {
        "trust": 0.1,
        "url": "https://kc.mcafee.com/corporate/index?page=content\u0026amp;id=sb10356"
      },
      {
        "trust": 0.1,
        "url": "https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/ccbfllvqvilivgzmbjl3ixzgkwqisynp/"
      },
      {
        "trust": 0.1,
        "url": "https://cwe.mitre.org/data/definitions/476.html"
      },
      {
        "trust": 0.1,
        "url": "https://github.com/terorie/cve-2021-3449"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      },
      {
        "trust": 0.1,
        "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-104-05"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2020-7774"
      },
      {
        "trust": 0.1,
        "url": "https://access.redhat.com/errata/rhsa-2021:2041"
      },
      {
        "trust": 0.1,
        "url": "https://access.redhat.com/security/cve/cve-2020-7774"
      },
      {
        "trust": 0.1,
        "url": "https://access.redhat.com/security/cve/cve-2020-7608"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2020-26289"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2021-3139"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2020-26160"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2020-7608"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2021-3528"
      },
      {
        "trust": 0.1,
        "url": "https://access.redhat.com/security/cve/cve-2020-8565"
      },
      {
        "trust": 0.1,
        "url": "https://access.redhat.com/security/cve/cve-2020-26160"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2020-8565"
      },
      {
        "trust": 0.1,
        "url": "https://access.redhat.com/documentation/en-us/red_hat_openshift_container_s"
      },
      {
        "trust": 0.1,
        "url": "https://access.redhat.com/security/cve/cve-2020-26289"
      },
      {
        "trust": 0.1,
        "url": "https://access.redhat.com/security/cve/cve-2020-8286"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2020-26116"
      },
      {
        "trust": 0.1,
        "url": "https://access.redhat.com/errata/rhsa-2021:2479"
      },
      {
        "trust": 0.1,
        "url": "https://access.redhat.com/security/cve/cve-2020-28196"
      },
      {
        "trust": 0.1,
        "url": "https://access.redhat.com/security/cve/cve-2020-15358"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2020-15358"
      },
      {
        "trust": 0.1,
        "url": "https://access.redhat.com/security/cve/cve-2021-23240"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2017-14502"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2020-27618"
      },
      {
        "trust": 0.1,
        "url": "https://access.redhat.com/security/cve/cve-2020-13543"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2020-26137"
      },
      {
        "trust": 0.1,
        "url": "https://access.redhat.com/security/cve/cve-2020-9951"
      },
      {
        "trust": 0.1,
        "url": "https://access.redhat.com/security/cve/cve-2020-13434"
      },
      {
        "trust": 0.1,
        "url": "https://access.redhat.com/security/cve/cve-2021-23239"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2020-13776"
      },
      {
        "trust": 0.1,
        "url": "https://access.redhat.com/security/cve/cve-2020-36242"
      },
      {
        "trust": 0.1,
        "url": "https://access.redhat.com/security/cve/cve-2019-3842"
      },
      {
        "trust": 0.1,
        "url": "https://access.redhat.com/security/cve/cve-2020-13776"
      },
      {
        "trust": 0.1,
        "url": "https://access.redhat.com/security/cve/cve-2020-24977"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2020-8231"
      },
      {
        "trust": 0.1,
        "url": "https://access.redhat.com/security/cve/cve-2020-8231"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2020-27619"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2020-24977"
      },
      {
        "trust": 0.1,
        "url": "https://access.redhat.com/security/cve/cve-2020-29362"
      },
      {
        "trust": 0.1,
        "url": "https://access.redhat.com/security/cve/cve-2020-9948"
      },
      {
        "trust": 0.1,
        "url": "https://access.redhat.com/security/cve/cve-2019-13012"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2020-13434"
      },
      {
        "trust": 0.1,
        "url": "https://access.redhat.com/security/cve/cve-2017-14502"
      },
      {
        "trust": 0.1,
        "url": "https://access.redhat.com/security/cve/cve-2020-8285"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2020-25659"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2016-10228"
      },
      {
        "trust": 0.1,
        "url": "https://access.redhat.com/security/cve/cve-2019-9169"
      },
      {
        "trust": 0.1,
        "url": "https://access.redhat.com/security/cve/cve-2019-14866"
      },
      {
        "trust": 0.1,
        "url": "https://access.redhat.com/security/cve/cve-2020-26116"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2019-14866"
      },
      {
        "trust": 0.1,
        "url": "https://access.redhat.com/security/cve/cve-2020-13584"
      },
      {
        "trust": 0.1,
        "url": "https://access.redhat.com/security/cve/cve-2020-26137"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2020-13543"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2019-25013"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2020-36242"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2020-13584"
      },
      {
        "trust": 0.1,
        "url": "https://access.redhat.com/security/cve/cve-2020-27783"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2020-28196"
      },
      {
        "trust": 0.1,
        "url": "https://access.redhat.com/security/cve/cve-2020-29361"
      },
      {
        "trust": 0.1,
        "url": "https://access.redhat.com/security/cve/cve-2020-25659"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2020-27783"
      },
      {
        "trust": 0.1,
        "url": "https://access.redhat.com/security/cve/cve-2020-27619"
      },
      {
        "trust": 0.1,
        "url": "https://access.redhat.com/security/cve/cve-2020-9983"
      },
      {
        "trust": 0.1,
        "url": "https://access.redhat.com/security/cve/cve-2021-3177"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2019-9169"
      },
      {
        "trust": 0.1,
        "url": "https://access.redhat.com/security/cve/cve-2021-3326"
      },
      {
        "trust": 0.1,
        "url": "https://access.redhat.com/security/cve/cve-2019-25013"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2020-29362"
      },
      {
        "trust": 0.1,
        "url": "https://access.redhat.com/security/cve/cve-2019-2708"
      },
      {
        "trust": 0.1,
        "url": "https://access.redhat.com/security/cve/cve-2021-23336"
      },
      {
        "trust": 0.1,
        "url": "https://access.redhat.com/security/cve/cve-2020-8927"
      },
      {
        "trust": 0.1,
        "url": "https://access.redhat.com/security/cve/cve-2020-29363"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2019-3842"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2019-13012"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2019-2708"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2020-29363"
      },
      {
        "trust": 0.1,
        "url": "https://access.redhat.com/security/cve/cve-2016-10228"
      },
      {
        "trust": 0.1,
        "url": "https://access.redhat.com/security/cve/cve-2020-8284"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2020-29361"
      },
      {
        "trust": 0.1,
        "url": "https://access.redhat.com/security/cve/cve-2020-27618"
      },
      {
        "trust": 0.1,
        "url": "https://access.redhat.com/security/cve/cve-2021-23358"
      },
      {
        "trust": 0.1,
        "url": "https://access.redhat.com/security/cve/cve-2020-15586"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2021-23358"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2020-16845"
      },
      {
        "trust": 0.1,
        "url": "https://access.redhat.com/security/cve/cve-2020-16845"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2020-15586"
      },
      {
        "trust": 0.1,
        "url": "https://access.redhat.com/errata/rhsa-2021:1448"
      },
      {
        "trust": 0.1,
        "url": "https://access.redhat.com/errata/rhsa-2021:1196"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2021-3115"
      },
      {
        "trust": 0.1,
        "url": "https://access.redhat.com/documentation/en-us/openshift_container_platform/"
      },
      {
        "trust": 0.1,
        "url": "https://access.redhat.com/documentation/en-us/openshift_container_platform/4.6/html/serverless_applications/index"
      },
      {
        "trust": 0.1,
        "url": "https://access.redhat.com/security/cve/cve-2021-3115"
      },
      {
        "trust": 0.1,
        "url": "https://access.redhat.com/errata/rhsa-2021:1338"
      },
      {
        "trust": 0.1,
        "url": "https://access.redhat.com/documentation/en-us/openshift_container_platform/4.7/html/serverless/index"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2021-23840"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2021-23841"
      },
      {
        "trust": 0.1,
        "url": "https://creativecommons.org/licenses/by-sa/2.5"
      },
      {
        "trust": 0.1,
        "url": "https://security.gentoo.org/"
      },
      {
        "trust": 0.1,
        "url": "https://bugs.gentoo.org."
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2021-20218"
      },
      {
        "trust": 0.1,
        "url": "https://access.redhat.com/security/cve/cve-2021-20218"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2021-3121"
      },
      {
        "trust": 0.1,
        "url": "https://access.redhat.com/errata/rhsa-2021:1369"
      },
      {
        "trust": 0.1,
        "url": "https://access.redhat.com/security/cve/cve-2021-3121"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2020-35149"
      },
      {
        "trust": 0.1,
        "url": "https://access.redhat.com/security/cve/cve-2020-35149"
      },
      {
        "trust": 0.1,
        "url": "https://access.redhat.com/security/cve/cve-2020-14040"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2020-14040"
      },
      {
        "trust": 0.1,
        "url": "https://access.redhat.com/errata/rhsa-2021:1200"
      },
      {
        "trust": 0.1,
        "url": "https://access.redhat.com/jbossnetwork/restricted/listsoftware.html?product=core.service.apachehttp\u0026downloadtype=securitypatches\u0026version=2.4.37"
      },
      {
        "trust": 0.1,
        "url": "https://ubuntu.com/security/notices/usn-5038-1"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2021-3677"
      },
      {
        "trust": 0.1,
        "url": "https://launchpad.net/ubuntu/+source/postgresql-10/10.18-0ubuntu0.18.04.1"
      },
      {
        "trust": 0.1,
        "url": "https://launchpad.net/ubuntu/+source/postgresql-12/12.8-0ubuntu0.20.04.1"
      },
      {
        "trust": 0.1,
        "url": "https://launchpad.net/ubuntu/+source/postgresql-13/13.4-0ubuntu0.21.04.1"
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-388130"
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-3449"
      },
      {
        "db": "PACKETSTORM",
        "id": "162699"
      },
      {
        "db": "PACKETSTORM",
        "id": "163209"
      },
      {
        "db": "PACKETSTORM",
        "id": "162383"
      },
      {
        "db": "PACKETSTORM",
        "id": "162183"
      },
      {
        "db": "PACKETSTORM",
        "id": "162307"
      },
      {
        "db": "PACKETSTORM",
        "id": "162041"
      },
      {
        "db": "PACKETSTORM",
        "id": "162337"
      },
      {
        "db": "PACKETSTORM",
        "id": "162197"
      },
      {
        "db": "PACKETSTORM",
        "id": "163815"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-3449"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "VULHUB",
        "id": "VHN-388130"
      },
      {
        "db": "VULMON",
        "id": "CVE-2021-3449"
      },
      {
        "db": "PACKETSTORM",
        "id": "162699"
      },
      {
        "db": "PACKETSTORM",
        "id": "163209"
      },
      {
        "db": "PACKETSTORM",
        "id": "162383"
      },
      {
        "db": "PACKETSTORM",
        "id": "162183"
      },
      {
        "db": "PACKETSTORM",
        "id": "162307"
      },
      {
        "db": "PACKETSTORM",
        "id": "162041"
      },
      {
        "db": "PACKETSTORM",
        "id": "162337"
      },
      {
        "db": "PACKETSTORM",
        "id": "162197"
      },
      {
        "db": "PACKETSTORM",
        "id": "163815"
      },
      {
        "db": "NVD",
        "id": "CVE-2021-3449"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2021-03-25T00:00:00",
        "db": "VULHUB",
        "id": "VHN-388130"
      },
      {
        "date": "2021-03-25T00:00:00",
        "db": "VULMON",
        "id": "CVE-2021-3449"
      },
      {
        "date": "2021-05-19T14:22:15",
        "db": "PACKETSTORM",
        "id": "162699"
      },
      {
        "date": "2021-06-17T18:34:10",
        "db": "PACKETSTORM",
        "id": "163209"
      },
      {
        "date": "2021-04-29T14:37:49",
        "db": "PACKETSTORM",
        "id": "162383"
      },
      {
        "date": "2021-04-14T16:40:32",
        "db": "PACKETSTORM",
        "id": "162183"
      },
      {
        "date": "2021-04-23T15:10:34",
        "db": "PACKETSTORM",
        "id": "162307"
      },
      {
        "date": "2021-03-31T14:36:01",
        "db": "PACKETSTORM",
        "id": "162041"
      },
      {
        "date": "2021-04-26T19:21:56",
        "db": "PACKETSTORM",
        "id": "162337"
      },
      {
        "date": "2021-04-15T13:50:04",
        "db": "PACKETSTORM",
        "id": "162197"
      },
      {
        "date": "2021-08-13T14:20:11",
        "db": "PACKETSTORM",
        "id": "163815"
      },
      {
        "date": "2021-03-25T15:15:13.450000",
        "db": "NVD",
        "id": "CVE-2021-3449"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-08-29T00:00:00",
        "db": "VULHUB",
        "id": "VHN-388130"
      },
      {
        "date": "2023-11-07T00:00:00",
        "db": "VULMON",
        "id": "CVE-2021-3449"
      },
      {
        "date": "2024-11-21T06:21:33.050000",
        "db": "NVD",
        "id": "CVE-2021-3449"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "PACKETSTORM",
        "id": "162041"
      },
      {
        "db": "PACKETSTORM",
        "id": "163815"
      }
    ],
    "trust": 0.2
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Red Hat Security Advisory 2021-2041-01",
    "sources": [
      {
        "db": "PACKETSTORM",
        "id": "162699"
      }
    ],
    "trust": 0.1
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "code execution",
    "sources": [
      {
        "db": "PACKETSTORM",
        "id": "162383"
      },
      {
        "db": "PACKETSTORM",
        "id": "162307"
      }
    ],
    "trust": 0.2
  }
}

VAR-201407-0606

Vulnerability from variot - Updated: 2025-04-13 23:14

The Project administration application in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, has a hardcoded encryption key, which allows remote attackers to obtain sensitive information by extracting this key from another product installation and then employing this key during the sniffing of network traffic on TCP port 1030. Supplementary information : CWE Vulnerability type by CWE-798: Use of Hard-coded Credentials ( Using hard-coded credentials ) Has been identified. Siemens SIMATIC WinCC is a multi-user system that provides complete monitoring and data acquisition (SCADA) functionality for the industrial sector, from single-user systems to redundant server and remote web client solutions. A privilege elevation vulnerability exists in Siemens SIMATIC WinCC and PCS7 that allows an attacker to exploit the vulnerability to gain administrative access on the affected device. Siemens SIMATIC WinCC and PCS7 are prone to a privilege-escalation vulnerability. Siemens SIMATIC WinCC is a set of automatic data acquisition and monitoring (SCADA) system of German Siemens (Siemens). The system provides process monitoring, data acquisition and other functions

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201407-0606",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": null,
        "scope": "eq",
        "trust": 2.4,
        "vendor": "wincc",
        "version": "6.0"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 2.4,
        "vendor": "wincc",
        "version": "7.0"
      },
      {
        "model": "wincc",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "6.0"
      },
      {
        "model": "wincc",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "5.0"
      },
      {
        "model": "wincc",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "7.0"
      },
      {
        "model": "simatic wincc",
        "scope": "lt",
        "trust": 1.4,
        "vendor": "siemens",
        "version": "7.3"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 1.2,
        "vendor": "wincc",
        "version": "5.0"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 1.2,
        "vendor": "wincc",
        "version": "7.1"
      },
      {
        "model": "wincc",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "7.1"
      },
      {
        "model": "wincc",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "7.2"
      },
      {
        "model": "simatic pcs7",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "8.0"
      },
      {
        "model": "simatic pcs7",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "8.0"
      },
      {
        "model": "simatic pcs7",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "7.1"
      },
      {
        "model": "simatic pcs 7",
        "scope": "lt",
        "trust": 0.8,
        "vendor": "siemens",
        "version": "8.1"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.6,
        "vendor": "simatic pcs7",
        "version": "7.1"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.6,
        "vendor": "simatic pcs7",
        "version": "8.0"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.6,
        "vendor": "simatic pcs7",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.6,
        "vendor": "wincc",
        "version": "*"
      },
      {
        "model": "pcs7",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "8.1"
      },
      {
        "model": "simatic wincc runtime advanced",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic wincc",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "6.2"
      },
      {
        "model": "simatic wincc",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "ea209009-7fdb-4811-b130-403cdc16f255"
      },
      {
        "db": "IVD",
        "id": "7d720861-463f-11e9-a37c-000c29342cb1"
      },
      {
        "db": "IVD",
        "id": "e2ce69a6-2351-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2014-04643"
      },
      {
        "db": "BID",
        "id": "68875"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2014-003569"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201407-606"
      },
      {
        "db": "NVD",
        "id": "CVE-2014-4686"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/a:siemens:simatic_pcs_7",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/a:siemens:simatic_wincc_%28tia_portal%29",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2014-003569"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Sergey Gordeychik, Alexander Tlyapov, Dmitry Nagibin, and Gleb Gritsai from Positive Technologies.",
    "sources": [
      {
        "db": "BID",
        "id": "68875"
      }
    ],
    "trust": 0.3
  },
  "cve": "CVE-2014-4686",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "PARTIAL",
            "baseScore": 6.8,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 8.6,
            "id": "CVE-2014-4686",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 1.8,
            "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 6.8,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 8.6,
            "id": "CNVD-2014-04643",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 0.6,
            "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "IVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 6.8,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 8.6,
            "id": "ea209009-7fdb-4811-b130-403cdc16f255",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 0.2,
            "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
            "version": "2.9 [IVD]"
          },
          {
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "IVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 6.8,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 8.6,
            "id": "7d720861-463f-11e9-a37c-000c29342cb1",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 0.2,
            "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
            "version": "2.9 [IVD]"
          },
          {
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "IVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 6.8,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 8.6,
            "id": "e2ce69a6-2351-11e6-abef-000c29c66e3d",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 0.2,
            "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
            "version": "2.9 [IVD]"
          },
          {
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "PARTIAL",
            "baseScore": 6.8,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 8.6,
            "id": "VHN-72627",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 0.1,
            "vectorString": "AV:N/AC:M/AU:N/C:P/I:P/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2014-4686",
            "trust": 1.0,
            "value": "MEDIUM"
          },
          {
            "author": "NVD",
            "id": "CVE-2014-4686",
            "trust": 0.8,
            "value": "Medium"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2014-04643",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201407-606",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "IVD",
            "id": "ea209009-7fdb-4811-b130-403cdc16f255",
            "trust": 0.2,
            "value": "MEDIUM"
          },
          {
            "author": "IVD",
            "id": "7d720861-463f-11e9-a37c-000c29342cb1",
            "trust": 0.2,
            "value": "MEDIUM"
          },
          {
            "author": "IVD",
            "id": "e2ce69a6-2351-11e6-abef-000c29c66e3d",
            "trust": 0.2,
            "value": "MEDIUM"
          },
          {
            "author": "VULHUB",
            "id": "VHN-72627",
            "trust": 0.1,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "ea209009-7fdb-4811-b130-403cdc16f255"
      },
      {
        "db": "IVD",
        "id": "7d720861-463f-11e9-a37c-000c29342cb1"
      },
      {
        "db": "IVD",
        "id": "e2ce69a6-2351-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2014-04643"
      },
      {
        "db": "VULHUB",
        "id": "VHN-72627"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2014-003569"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201407-606"
      },
      {
        "db": "NVD",
        "id": "CVE-2014-4686"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "The Project administration application in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, has a hardcoded encryption key, which allows remote attackers to obtain sensitive information by extracting this key from another product installation and then employing this key during the sniffing of network traffic on TCP port 1030. Supplementary information : CWE Vulnerability type by CWE-798: Use of Hard-coded Credentials ( Using hard-coded credentials ) Has been identified. Siemens SIMATIC WinCC is a multi-user system that provides complete monitoring and data acquisition (SCADA) functionality for the industrial sector, from single-user systems to redundant server and remote web client solutions. A privilege elevation vulnerability exists in Siemens SIMATIC WinCC and PCS7 that allows an attacker to exploit the vulnerability to gain administrative access on the affected device. Siemens SIMATIC WinCC and PCS7 are prone to a privilege-escalation vulnerability. Siemens SIMATIC WinCC is a set of automatic data acquisition and monitoring (SCADA) system of German Siemens (Siemens). The system provides process monitoring, data acquisition and other functions",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2014-4686"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2014-003569"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2014-04643"
      },
      {
        "db": "BID",
        "id": "68875"
      },
      {
        "db": "IVD",
        "id": "ea209009-7fdb-4811-b130-403cdc16f255"
      },
      {
        "db": "IVD",
        "id": "7d720861-463f-11e9-a37c-000c29342cb1"
      },
      {
        "db": "IVD",
        "id": "e2ce69a6-2351-11e6-abef-000c29c66e3d"
      },
      {
        "db": "VULHUB",
        "id": "VHN-72627"
      }
    ],
    "trust": 3.06
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2014-4686",
        "trust": 4.2
      },
      {
        "db": "SIEMENS",
        "id": "SSA-214365",
        "trust": 2.3
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201407-606",
        "trust": 1.3
      },
      {
        "db": "CNVD",
        "id": "CNVD-2014-04643",
        "trust": 1.2
      },
      {
        "db": "BID",
        "id": "68875",
        "trust": 1.0
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-14-205-02",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2014-003569",
        "trust": 0.8
      },
      {
        "db": "SECUNIA",
        "id": "60392",
        "trust": 0.6
      },
      {
        "db": "SECUNIA",
        "id": "60388",
        "trust": 0.6
      },
      {
        "db": "IVD",
        "id": "EA209009-7FDB-4811-B130-403CDC16F255",
        "trust": 0.2
      },
      {
        "db": "IVD",
        "id": "7D720861-463F-11E9-A37C-000C29342CB1",
        "trust": 0.2
      },
      {
        "db": "IVD",
        "id": "E2CE69A6-2351-11E6-ABEF-000C29C66E3D",
        "trust": 0.2
      },
      {
        "db": "PACKETSTORM",
        "id": "130406",
        "trust": 0.2
      },
      {
        "db": "VULHUB",
        "id": "VHN-72627",
        "trust": 0.1
      },
      {
        "db": "PACKETSTORM",
        "id": "127660",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "ea209009-7fdb-4811-b130-403cdc16f255"
      },
      {
        "db": "IVD",
        "id": "7d720861-463f-11e9-a37c-000c29342cb1"
      },
      {
        "db": "IVD",
        "id": "e2ce69a6-2351-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2014-04643"
      },
      {
        "db": "VULHUB",
        "id": "VHN-72627"
      },
      {
        "db": "BID",
        "id": "68875"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2014-003569"
      },
      {
        "db": "PACKETSTORM",
        "id": "130406"
      },
      {
        "db": "PACKETSTORM",
        "id": "127660"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201407-606"
      },
      {
        "db": "NVD",
        "id": "CVE-2014-4686"
      }
    ]
  },
  "id": "VAR-201407-0606",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "IVD",
        "id": "ea209009-7fdb-4811-b130-403cdc16f255"
      },
      {
        "db": "IVD",
        "id": "7d720861-463f-11e9-a37c-000c29342cb1"
      },
      {
        "db": "IVD",
        "id": "e2ce69a6-2351-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2014-04643"
      },
      {
        "db": "VULHUB",
        "id": "VHN-72627"
      }
    ],
    "trust": 1.9749411600000002
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 1.2
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "ea209009-7fdb-4811-b130-403cdc16f255"
      },
      {
        "db": "IVD",
        "id": "7d720861-463f-11e9-a37c-000c29342cb1"
      },
      {
        "db": "IVD",
        "id": "e2ce69a6-2351-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2014-04643"
      }
    ]
  },
  "last_update_date": "2025-04-13T23:14:45.887000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "SSA-214365",
        "trust": 0.8,
        "url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-214365.pdf"
      },
      {
        "title": "Patch for Siemens SIMATIC WinCC and PCS7 Privilege Escalation Vulnerability",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/47905"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2014-04643"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2014-003569"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "NVD-CWE-Other",
        "trust": 1.0
      },
      {
        "problemtype": "CWE-Other",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2014-003569"
      },
      {
        "db": "NVD",
        "id": "CVE-2014-4686"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.3,
        "url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-214365.pdf"
      },
      {
        "trust": 1.4,
        "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2014-4686"
      },
      {
        "trust": 0.8,
        "url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2014-4686"
      },
      {
        "trust": 0.8,
        "url": "https://ics-cert.us-cert.gov/advisories/icsa-14-205-02"
      },
      {
        "trust": 0.6,
        "url": "http://www.securityfocus.com/bid/68875"
      },
      {
        "trust": 0.6,
        "url": "http://secunia.com/advisories/60388"
      },
      {
        "trust": 0.6,
        "url": "http://secunia.com/advisories/60392"
      },
      {
        "trust": 0.3,
        "url": "http://subscriber.communications.siemens.com/"
      },
      {
        "trust": 0.2,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2014-4686"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2015-1358"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2014-4684"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2014-4683"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2014-4685"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2014-4682"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2014-04643"
      },
      {
        "db": "VULHUB",
        "id": "VHN-72627"
      },
      {
        "db": "BID",
        "id": "68875"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2014-003569"
      },
      {
        "db": "PACKETSTORM",
        "id": "130406"
      },
      {
        "db": "PACKETSTORM",
        "id": "127660"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201407-606"
      },
      {
        "db": "NVD",
        "id": "CVE-2014-4686"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "IVD",
        "id": "ea209009-7fdb-4811-b130-403cdc16f255"
      },
      {
        "db": "IVD",
        "id": "7d720861-463f-11e9-a37c-000c29342cb1"
      },
      {
        "db": "IVD",
        "id": "e2ce69a6-2351-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2014-04643"
      },
      {
        "db": "VULHUB",
        "id": "VHN-72627"
      },
      {
        "db": "BID",
        "id": "68875"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2014-003569"
      },
      {
        "db": "PACKETSTORM",
        "id": "130406"
      },
      {
        "db": "PACKETSTORM",
        "id": "127660"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201407-606"
      },
      {
        "db": "NVD",
        "id": "CVE-2014-4686"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2014-07-28T00:00:00",
        "db": "IVD",
        "id": "ea209009-7fdb-4811-b130-403cdc16f255"
      },
      {
        "date": "2014-07-28T00:00:00",
        "db": "IVD",
        "id": "7d720861-463f-11e9-a37c-000c29342cb1"
      },
      {
        "date": "2014-07-28T00:00:00",
        "db": "IVD",
        "id": "e2ce69a6-2351-11e6-abef-000c29c66e3d"
      },
      {
        "date": "2014-07-28T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2014-04643"
      },
      {
        "date": "2014-07-24T00:00:00",
        "db": "VULHUB",
        "id": "VHN-72627"
      },
      {
        "date": "2014-07-23T00:00:00",
        "db": "BID",
        "id": "68875"
      },
      {
        "date": "2014-07-28T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2014-003569"
      },
      {
        "date": "2015-02-16T17:36:59",
        "db": "PACKETSTORM",
        "id": "130406"
      },
      {
        "date": "2014-07-29T22:37:22",
        "db": "PACKETSTORM",
        "id": "127660"
      },
      {
        "date": "2014-07-25T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201407-606"
      },
      {
        "date": "2014-07-24T14:55:08.190000",
        "db": "NVD",
        "id": "CVE-2014-4686"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2014-07-28T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2014-04643"
      },
      {
        "date": "2014-07-25T00:00:00",
        "db": "VULHUB",
        "id": "VHN-72627"
      },
      {
        "date": "2015-03-19T09:08:00",
        "db": "BID",
        "id": "68875"
      },
      {
        "date": "2014-08-05T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2014-003569"
      },
      {
        "date": "2014-07-25T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201407-606"
      },
      {
        "date": "2025-04-12T10:46:40.837000",
        "db": "NVD",
        "id": "CVE-2014-4686"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "PACKETSTORM",
        "id": "130406"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201407-606"
      }
    ],
    "trust": 0.7
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Siemens SIMATIC PCS 7 Used in products such as  SIMATIC WinCC Vulnerabilities in which important information is obtained in project management applications",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2014-003569"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Encryption issues",
    "sources": [
      {
        "db": "IVD",
        "id": "ea209009-7fdb-4811-b130-403cdc16f255"
      },
      {
        "db": "IVD",
        "id": "7d720861-463f-11e9-a37c-000c29342cb1"
      },
      {
        "db": "IVD",
        "id": "e2ce69a6-2351-11e6-abef-000c29c66e3d"
      }
    ],
    "trust": 0.6
  }
}

VAR-201502-0370

Vulnerability from variot - Updated: 2025-04-13 23:14

The remote-management module in the (1) Multi Panels, (2) Comfort Panels, and (3) RT Advanced functionality in Siemens SIMATIC WinCC (TIA Portal) before 13 SP1 and in the (4) panels and (5) runtime functionality in SIMATIC WinCC flexible before 2008 SP3 Up7 does not properly encrypt credentials in transit, which makes it easier for remote attackers to determine cleartext credentials by sniffing the network and conducting a decryption attack. Siemens SIMATIC WinCC is a monitoring control and data acquisition SCADA and human machine interface HMI system. An information disclosure vulnerability exists in Siemens SIMATIC WinCC V13 SP1 that could allow an attacker to obtain sensitive information through man-in-the-middle attacks. Versions prior to Siemens SIMATIC WinCC TIA Portal V13 SP1 are vulnerable. The vulnerability stems from the fact that the program does not properly encrypt the certificate in transmission. A remote attacker could exploit this vulnerability by sniffing the network and performing a decryption attack to obtain clear text certificates

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201502-0370",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "wincc",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "13.0"
      },
      {
        "model": "simatic wincc",
        "scope": "lt",
        "trust": 0.8,
        "vendor": "siemens",
        "version": "13 sp1"
      },
      {
        "model": "simatic wincc tia portal sp1",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v13"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.4,
        "vendor": "wincc",
        "version": "13.0"
      },
      {
        "model": "simatic wincc flexible runtime",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic wincc flexible sp2",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "2008"
      },
      {
        "model": "simatic wincc flexible sp1",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "2008"
      },
      {
        "model": "simatic wincc flexible",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "2008"
      },
      {
        "model": "simatic wincc flexible",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "2007"
      },
      {
        "model": "simatic wincc flexible sp1",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "2005"
      },
      {
        "model": "simatic wincc flexible",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "2005"
      },
      {
        "model": "simatic wincc flexible",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "2004"
      },
      {
        "model": "simatic wincc runtime advanced",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "6c5f6ee2-c09b-4c78-a362-83203bbfe346"
      },
      {
        "db": "IVD",
        "id": "a11e037c-2351-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2015-01296"
      },
      {
        "db": "BID",
        "id": "72625"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2015-001537"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201502-420"
      },
      {
        "db": "NVD",
        "id": "CVE-2015-1358"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/a:siemens:simatic_wincc_%28tia_portal%29",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2015-001537"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Gleb Gritsai, Roman Ilin, Aleksandr Tlyapov, and Sergey Gordeychik.",
    "sources": [
      {
        "db": "BID",
        "id": "72625"
      }
    ],
    "trust": 0.3
  },
  "cve": "CVE-2015-1358",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "NONE",
            "baseScore": 5.0,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CVE-2015-1358",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 1.8,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "NONE",
            "baseScore": 5.0,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2015-01296",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "IVD",
            "availabilityImpact": "NONE",
            "baseScore": 5.0,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "6c5f6ee2-c09b-4c78-a362-83203bbfe346",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 0.2,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
            "version": "2.9 [IVD]"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "IVD",
            "availabilityImpact": "NONE",
            "baseScore": 5.0,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "a11e037c-2351-11e6-abef-000c29c66e3d",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 0.2,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
            "version": "2.9 [IVD]"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "NONE",
            "baseScore": 5.0,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "VHN-79319",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 0.1,
            "vectorString": "AV:N/AC:L/AU:N/C:P/I:N/A:N",
            "version": "2.0"
          }
        ],
        "cvssV3": [],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2015-1358",
            "trust": 1.0,
            "value": "MEDIUM"
          },
          {
            "author": "NVD",
            "id": "CVE-2015-1358",
            "trust": 0.8,
            "value": "Medium"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2015-01296",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201502-420",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "IVD",
            "id": "6c5f6ee2-c09b-4c78-a362-83203bbfe346",
            "trust": 0.2,
            "value": "MEDIUM"
          },
          {
            "author": "IVD",
            "id": "a11e037c-2351-11e6-abef-000c29c66e3d",
            "trust": 0.2,
            "value": "MEDIUM"
          },
          {
            "author": "VULHUB",
            "id": "VHN-79319",
            "trust": 0.1,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "6c5f6ee2-c09b-4c78-a362-83203bbfe346"
      },
      {
        "db": "IVD",
        "id": "a11e037c-2351-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2015-01296"
      },
      {
        "db": "VULHUB",
        "id": "VHN-79319"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2015-001537"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201502-420"
      },
      {
        "db": "NVD",
        "id": "CVE-2015-1358"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "The remote-management module in the (1) Multi Panels, (2) Comfort Panels, and (3) RT Advanced functionality in Siemens SIMATIC WinCC (TIA Portal) before 13 SP1 and in the (4) panels and (5) runtime functionality in SIMATIC WinCC flexible before 2008 SP3 Up7 does not properly encrypt credentials in transit, which makes it easier for remote attackers to determine cleartext credentials by sniffing the network and conducting a decryption attack. Siemens SIMATIC WinCC is a monitoring control and data acquisition SCADA and human machine interface HMI system. An information disclosure vulnerability exists in Siemens SIMATIC WinCC V13 SP1 that could allow an attacker to obtain sensitive information through man-in-the-middle attacks. \nVersions prior to Siemens SIMATIC WinCC TIA Portal V13 SP1 are vulnerable. The vulnerability stems from the fact that the program does not properly encrypt the certificate in transmission. A remote attacker could exploit this vulnerability by sniffing the network and performing a decryption attack to obtain clear text certificates",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2015-1358"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2015-001537"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2015-01296"
      },
      {
        "db": "BID",
        "id": "72625"
      },
      {
        "db": "IVD",
        "id": "6c5f6ee2-c09b-4c78-a362-83203bbfe346"
      },
      {
        "db": "IVD",
        "id": "a11e037c-2351-11e6-abef-000c29c66e3d"
      },
      {
        "db": "VULHUB",
        "id": "VHN-79319"
      }
    ],
    "trust": 2.88
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2015-1358",
        "trust": 3.9
      },
      {
        "db": "SIEMENS",
        "id": "SSA-543623",
        "trust": 2.3
      },
      {
        "db": "BID",
        "id": "72625",
        "trust": 2.0
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-16-161-02",
        "trust": 1.9
      },
      {
        "db": "SIEMENS",
        "id": "SSA-526760",
        "trust": 1.7
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201502-420",
        "trust": 1.1
      },
      {
        "db": "SECTRACK",
        "id": "1036090",
        "trust": 1.1
      },
      {
        "db": "CNVD",
        "id": "CNVD-2015-01296",
        "trust": 1.0
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2015-001537",
        "trust": 0.8
      },
      {
        "db": "IVD",
        "id": "6C5F6EE2-C09B-4C78-A362-83203BBFE346",
        "trust": 0.2
      },
      {
        "db": "IVD",
        "id": "A11E037C-2351-11E6-ABEF-000C29C66E3D",
        "trust": 0.2
      },
      {
        "db": "VULHUB",
        "id": "VHN-79319",
        "trust": 0.1
      },
      {
        "db": "PACKETSTORM",
        "id": "130406",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "6c5f6ee2-c09b-4c78-a362-83203bbfe346"
      },
      {
        "db": "IVD",
        "id": "a11e037c-2351-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2015-01296"
      },
      {
        "db": "VULHUB",
        "id": "VHN-79319"
      },
      {
        "db": "BID",
        "id": "72625"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2015-001537"
      },
      {
        "db": "PACKETSTORM",
        "id": "130406"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201502-420"
      },
      {
        "db": "NVD",
        "id": "CVE-2015-1358"
      }
    ]
  },
  "id": "VAR-201502-0370",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "IVD",
        "id": "6c5f6ee2-c09b-4c78-a362-83203bbfe346"
      },
      {
        "db": "IVD",
        "id": "a11e037c-2351-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2015-01296"
      },
      {
        "db": "VULHUB",
        "id": "VHN-79319"
      }
    ],
    "trust": 1.7615187142857143
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 1.0
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "6c5f6ee2-c09b-4c78-a362-83203bbfe346"
      },
      {
        "db": "IVD",
        "id": "a11e037c-2351-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2015-01296"
      }
    ]
  },
  "last_update_date": "2025-04-13T23:14:45.736000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "SSA-543623",
        "trust": 0.8,
        "url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-543623.pdf"
      },
      {
        "title": "Patch for Siemens SIMATIC WinCC TIA Portal Man-in-the-Middle Information Disclosure Vulnerability",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/55531"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2015-01296"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2015-001537"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-310",
        "trust": 1.9
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-79319"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2015-001537"
      },
      {
        "db": "NVD",
        "id": "CVE-2015-1358"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.3,
        "url": "http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-543623.pdf"
      },
      {
        "trust": 1.9,
        "url": "https://ics-cert.us-cert.gov/advisories/icsa-16-161-02"
      },
      {
        "trust": 1.7,
        "url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-526760.pdf"
      },
      {
        "trust": 1.7,
        "url": "http://www.securityfocus.com/bid/72625"
      },
      {
        "trust": 1.1,
        "url": "http://www.securitytracker.com/id/1036090"
      },
      {
        "trust": 0.8,
        "url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2015-1358"
      },
      {
        "trust": 0.8,
        "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2015-1358"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2015-1358"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2014-4686"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2015-01296"
      },
      {
        "db": "VULHUB",
        "id": "VHN-79319"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2015-001537"
      },
      {
        "db": "PACKETSTORM",
        "id": "130406"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201502-420"
      },
      {
        "db": "NVD",
        "id": "CVE-2015-1358"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "IVD",
        "id": "6c5f6ee2-c09b-4c78-a362-83203bbfe346"
      },
      {
        "db": "IVD",
        "id": "a11e037c-2351-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2015-01296"
      },
      {
        "db": "VULHUB",
        "id": "VHN-79319"
      },
      {
        "db": "BID",
        "id": "72625"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2015-001537"
      },
      {
        "db": "PACKETSTORM",
        "id": "130406"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201502-420"
      },
      {
        "db": "NVD",
        "id": "CVE-2015-1358"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2015-02-27T00:00:00",
        "db": "IVD",
        "id": "6c5f6ee2-c09b-4c78-a362-83203bbfe346"
      },
      {
        "date": "2015-02-27T00:00:00",
        "db": "IVD",
        "id": "a11e037c-2351-11e6-abef-000c29c66e3d"
      },
      {
        "date": "2015-02-26T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2015-01296"
      },
      {
        "date": "2015-02-18T00:00:00",
        "db": "VULHUB",
        "id": "VHN-79319"
      },
      {
        "date": "2015-02-13T00:00:00",
        "db": "BID",
        "id": "72625"
      },
      {
        "date": "2015-02-20T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2015-001537"
      },
      {
        "date": "2015-02-16T17:36:59",
        "db": "PACKETSTORM",
        "id": "130406"
      },
      {
        "date": "2015-02-28T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201502-420"
      },
      {
        "date": "2015-02-18T02:59:07.813000",
        "db": "NVD",
        "id": "CVE-2015-1358"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2016-06-12T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2015-01296"
      },
      {
        "date": "2016-11-30T00:00:00",
        "db": "VULHUB",
        "id": "VHN-79319"
      },
      {
        "date": "2016-07-06T14:57:00",
        "db": "BID",
        "id": "72625"
      },
      {
        "date": "2016-06-10T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2015-001537"
      },
      {
        "date": "2015-02-28T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201502-420"
      },
      {
        "date": "2025-04-12T10:46:40.837000",
        "db": "NVD",
        "id": "CVE-2015-1358"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "PACKETSTORM",
        "id": "130406"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201502-420"
      }
    ],
    "trust": 0.7
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Siemens SIMATIC WinCC TIA Portal Man-in-the-middle information disclosure vulnerability",
    "sources": [
      {
        "db": "IVD",
        "id": "6c5f6ee2-c09b-4c78-a362-83203bbfe346"
      },
      {
        "db": "IVD",
        "id": "a11e037c-2351-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2015-01296"
      }
    ],
    "trust": 1.0
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "encryption problem",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201502-420"
      }
    ],
    "trust": 0.6
  }
}

VAR-201109-0223

Vulnerability from variot - Updated: 2025-04-11 23:02

Heap-based buffer overflow in the Siemens WinCC Runtime Advanced Loader, as used in SIMATIC WinCC flexible Runtime and SIMATIC WinCC (TIA Portal) Runtime Advanced, allows remote attackers to cause a denial of service (memory corruption) or possibly execute arbitrary code via a crafted packet to TCP port 2308. Siemens SIMATIC WinCC flexible and WinCC (TIA Portal) Runtime Advanced is a software package for virtualization. A security vulnerability exists in the implementation of Siemens SIMATIC WinCC, which can be exploited by malicious users to control the affected system. This vulnerability stems from an error in the runtime loader when parsing a received message, causing a heap buffer overflow through a specially crafted message sent to port 2308/TCP. ----------------------------------------------------------------------

The new Secunia Corporate Software Inspector (CSI) 5.0 Integrates with Microsoft WSUS & SCCM and supports Apple Mac OS X.

Get a free trial now and qualify for a special discount: http://secunia.com/vulnerability_scanning/corporate/trial/


TITLE: Siemens SIMATIC WinCC Runtime Loader Buffer Overflow Vulnerability

SECUNIA ADVISORY ID: SA46011

VERIFY ADVISORY: Secunia.com http://secunia.com/advisories/46011/ Customer Area (Credentials Required) https://ca.secunia.com/?page=viewadvisory&vuln_id=46011

RELEASE DATE: 2011-09-15

DISCUSS ADVISORY: http://secunia.com/advisories/46011/#comments

AVAILABLE ON SITE AND IN CUSTOMER AREA: * Last Update * Popularity * Comments * Criticality Level * Impact * Where * Solution Status * Operating System / Software * CVE Reference(s)

http://secunia.com/advisories/46011/

ONLY AVAILABLE IN CUSTOMER AREA: * Authentication Level * Report Reliability * Secunia PoC * Secunia Analysis * Systems Affected * Approve Distribution * Remediation Status * Secunia CVSS Score * CVSS

https://ca.secunia.com/?page=viewadvisory&vuln_id=46011

ONLY AVAILABLE WITH SECUNIA CSI AND SECUNIA PSI: * AUTOMATED SCANNING

http://secunia.com/vulnerability_scanning/personal/ http://secunia.com/vulnerability_scanning/corporate/wsus_sccm_3rd_third_party_patching/

DESCRIPTION: A vulnerability has been reported in Siemens SIMATIC WinCC, which can be exploited by malicious people to potentially compromise a vulnerable system.

Successful exploitation may allow execution of arbitrary code, but requires that "transfer" mode is enabled (disabled by default).

SOLUTION: Disable "transfer" mode or restrict access to port 2308/TCP.

PROVIDED AND/OR DISCOVERED BY: Billy Rios and Terry McCorkle via ICS-CERT.

ORIGINAL ADVISORY: Siemens: http://support.automation.siemens.com/WW/llisapi.dll?func=cslib.csinfo&lang=de&objid=29054992&caller=view http://cache.automation.siemens.com/dnl/jI/jI0NDY5AAAA_29054992_FAQ/Siemens_Security_Advisory_SSA-460621_V1_2.pdf

ICS-CERT: http://www.us-cert.gov/control_systems/pdf/ICSA-11-244-01.pdf

OTHER REFERENCES: Further details available in Customer Area: http://secunia.com/vulnerability_intelligence/

DEEP LINKS: Further details available in Customer Area: http://secunia.com/vulnerability_intelligence/

EXTENDED DESCRIPTION: Further details available in Customer Area: http://secunia.com/vulnerability_intelligence/

EXTENDED SOLUTION: Further details available in Customer Area: http://secunia.com/vulnerability_intelligence/

EXPLOIT: Further details available in Customer Area: http://secunia.com/vulnerability_intelligence/


About: This Advisory was delivered by Secunia as a free service to help private users keeping their systems up to date against the latest vulnerabilities.

Subscribe: http://secunia.com/advisories/secunia_security_advisories/

Definitions: (Criticality, Where etc.) http://secunia.com/advisories/about_secunia_advisories/

Please Note: Secunia recommends that you verify all advisories you receive by clicking the link. Secunia NEVER sends attached files with advisories. Secunia does not advise people to install third party patches, only use those supplied by the vendor.


Unsubscribe: Secunia Security Advisories http://secunia.com/sec_adv_unsubscribe/?email=packet%40packetstormsecurity.org


Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201109-0223",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "simatic wincc runtime",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic wincc flexible runtime",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic wincc flexible rumtime",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic wincc runtime advanced",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": null,
        "scope": null,
        "trust": 0.6,
        "vendor": "no",
        "version": null
      },
      {
        "model": "simatic wincc flexible runtime",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.4,
        "vendor": "simatic wincc flexible runtime",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.4,
        "vendor": "simatic wincc runtime",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "7d7d7a11-463f-11e9-84c1-000c29342cb1"
      },
      {
        "db": "IVD",
        "id": "a57fd672-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-6876"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2011-002270"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201109-224"
      },
      {
        "db": "NVD",
        "id": "CVE-2011-3321"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/a:siemens:wincc_flexible_runtime",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/a:siemens:wincc_runtime_advanced",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2011-002270"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Secunia",
    "sources": [
      {
        "db": "PACKETSTORM",
        "id": "105133"
      }
    ],
    "trust": 0.1
  },
  "cve": "CVE-2011-3321",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "COMPLETE",
            "baseScore": 9.3,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 8.6,
            "id": "CVE-2011-3321",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 1.8,
            "vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 9.3,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 8.6,
            "id": "CNVD-2011-6876",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "IVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 9.3,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 8.6,
            "id": "7d7d7a11-463f-11e9-84c1-000c29342cb1",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.2,
            "vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C",
            "version": "2.9 [IVD]"
          },
          {
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "IVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 9.3,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 8.6,
            "id": "a57fd672-2354-11e6-abef-000c29c66e3d",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.2,
            "vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C",
            "version": "2.9 [IVD]"
          },
          {
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "COMPLETE",
            "baseScore": 9.3,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 8.6,
            "id": "VHN-51266",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.1,
            "vectorString": "AV:N/AC:M/AU:N/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2011-3321",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "NVD",
            "id": "CVE-2011-3321",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2011-6876",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201109-224",
            "trust": 0.6,
            "value": "CRITICAL"
          },
          {
            "author": "IVD",
            "id": "7d7d7a11-463f-11e9-84c1-000c29342cb1",
            "trust": 0.2,
            "value": "CRITICAL"
          },
          {
            "author": "IVD",
            "id": "a57fd672-2354-11e6-abef-000c29c66e3d",
            "trust": 0.2,
            "value": "CRITICAL"
          },
          {
            "author": "VULHUB",
            "id": "VHN-51266",
            "trust": 0.1,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "7d7d7a11-463f-11e9-84c1-000c29342cb1"
      },
      {
        "db": "IVD",
        "id": "a57fd672-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-6876"
      },
      {
        "db": "VULHUB",
        "id": "VHN-51266"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2011-002270"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201109-224"
      },
      {
        "db": "NVD",
        "id": "CVE-2011-3321"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Heap-based buffer overflow in the Siemens WinCC Runtime Advanced Loader, as used in SIMATIC WinCC flexible Runtime and SIMATIC WinCC (TIA Portal) Runtime Advanced, allows remote attackers to cause a denial of service (memory corruption) or possibly execute arbitrary code via a crafted packet to TCP port 2308. Siemens SIMATIC WinCC flexible and WinCC (TIA Portal) Runtime Advanced is a software package for virtualization. A security vulnerability exists in the implementation of Siemens SIMATIC WinCC, which can be exploited by malicious users to control the affected system. This vulnerability stems from an error in the runtime loader when parsing a received message, causing a heap buffer overflow through a specially crafted message sent to port 2308/TCP. ----------------------------------------------------------------------\n\nThe new Secunia Corporate Software Inspector (CSI) 5.0 \nIntegrates with Microsoft WSUS \u0026 SCCM and supports Apple Mac OS X. \n\nGet a free trial now and qualify for a special discount:\nhttp://secunia.com/vulnerability_scanning/corporate/trial/\n\n----------------------------------------------------------------------\n\nTITLE:\nSiemens SIMATIC WinCC Runtime Loader Buffer Overflow Vulnerability\n\nSECUNIA ADVISORY ID:\nSA46011\n\nVERIFY ADVISORY:\nSecunia.com\nhttp://secunia.com/advisories/46011/\nCustomer Area (Credentials Required)\nhttps://ca.secunia.com/?page=viewadvisory\u0026vuln_id=46011\n\nRELEASE DATE:\n2011-09-15\n\nDISCUSS ADVISORY:\nhttp://secunia.com/advisories/46011/#comments\n\nAVAILABLE ON SITE AND IN CUSTOMER AREA:\n * Last Update\n * Popularity\n * Comments\n * Criticality Level\n * Impact\n * Where\n * Solution Status\n * Operating System / Software\n * CVE Reference(s)\n\nhttp://secunia.com/advisories/46011/\n\nONLY AVAILABLE IN CUSTOMER AREA:\n * Authentication Level\n * Report Reliability\n * Secunia PoC\n * Secunia Analysis\n * Systems Affected\n * Approve Distribution\n * Remediation Status\n * Secunia CVSS Score\n * CVSS\n\nhttps://ca.secunia.com/?page=viewadvisory\u0026vuln_id=46011\n\nONLY AVAILABLE WITH SECUNIA CSI AND SECUNIA PSI:\n * AUTOMATED SCANNING\n\nhttp://secunia.com/vulnerability_scanning/personal/\nhttp://secunia.com/vulnerability_scanning/corporate/wsus_sccm_3rd_third_party_patching/\n\nDESCRIPTION:\nA vulnerability has been reported in Siemens SIMATIC WinCC, which can\nbe exploited by malicious people to potentially compromise a\nvulnerable system. \n\nSuccessful exploitation may allow execution of arbitrary code, but\nrequires that \"transfer\" mode is enabled (disabled by default). \n\nSOLUTION:\nDisable \"transfer\" mode or restrict access to port 2308/TCP. \n\nPROVIDED AND/OR DISCOVERED BY:\nBilly Rios and Terry McCorkle via ICS-CERT. \n\nORIGINAL ADVISORY:\nSiemens:\nhttp://support.automation.siemens.com/WW/llisapi.dll?func=cslib.csinfo\u0026lang=de\u0026objid=29054992\u0026caller=view\nhttp://cache.automation.siemens.com/dnl/jI/jI0NDY5AAAA_29054992_FAQ/Siemens_Security_Advisory_SSA-460621_V1_2.pdf\n\nICS-CERT:\nhttp://www.us-cert.gov/control_systems/pdf/ICSA-11-244-01.pdf\n\nOTHER REFERENCES:\nFurther details available in Customer Area:\nhttp://secunia.com/vulnerability_intelligence/\n\nDEEP LINKS:\nFurther details available in Customer Area:\nhttp://secunia.com/vulnerability_intelligence/\n\nEXTENDED DESCRIPTION:\nFurther details available in Customer Area:\nhttp://secunia.com/vulnerability_intelligence/\n\nEXTENDED SOLUTION:\nFurther details available in Customer Area:\nhttp://secunia.com/vulnerability_intelligence/\n\nEXPLOIT:\nFurther details available in Customer Area:\nhttp://secunia.com/vulnerability_intelligence/\n\n----------------------------------------------------------------------\n\nAbout:\nThis Advisory was delivered by Secunia as a free service to help\nprivate users keeping their systems up to date against the latest\nvulnerabilities. \n\nSubscribe:\nhttp://secunia.com/advisories/secunia_security_advisories/\n\nDefinitions: (Criticality, Where etc.)\nhttp://secunia.com/advisories/about_secunia_advisories/\n\n\nPlease Note:\nSecunia recommends that you verify all advisories you receive by\nclicking the link. \nSecunia NEVER sends attached files with advisories. \nSecunia does not advise people to install third party patches, only\nuse those supplied by the vendor. \n\n----------------------------------------------------------------------\n\nUnsubscribe: Secunia Security Advisories\nhttp://secunia.com/sec_adv_unsubscribe/?email=packet%40packetstormsecurity.org\n\n----------------------------------------------------------------------\n\n\n",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2011-3321"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2011-002270"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-6876"
      },
      {
        "db": "IVD",
        "id": "7d7d7a11-463f-11e9-84c1-000c29342cb1"
      },
      {
        "db": "IVD",
        "id": "a57fd672-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "VULHUB",
        "id": "VHN-51266"
      },
      {
        "db": "PACKETSTORM",
        "id": "105133"
      }
    ],
    "trust": 2.7
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2011-3321",
        "trust": 3.5
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-11-244-01",
        "trust": 2.6
      },
      {
        "db": "SECUNIA",
        "id": "46011",
        "trust": 2.0
      },
      {
        "db": "SIEMENS",
        "id": "SSA-460621",
        "trust": 1.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-6876",
        "trust": 1.0
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201109-224",
        "trust": 1.0
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2011-002270",
        "trust": 0.8
      },
      {
        "db": "NSFOCUS",
        "id": "17733",
        "trust": 0.6
      },
      {
        "db": "IVD",
        "id": "7D7D7A11-463F-11E9-84C1-000C29342CB1",
        "trust": 0.2
      },
      {
        "db": "IVD",
        "id": "A57FD672-2354-11E6-ABEF-000C29C66E3D",
        "trust": 0.2
      },
      {
        "db": "VULHUB",
        "id": "VHN-51266",
        "trust": 0.1
      },
      {
        "db": "PACKETSTORM",
        "id": "105133",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "7d7d7a11-463f-11e9-84c1-000c29342cb1"
      },
      {
        "db": "IVD",
        "id": "a57fd672-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-6876"
      },
      {
        "db": "VULHUB",
        "id": "VHN-51266"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2011-002270"
      },
      {
        "db": "PACKETSTORM",
        "id": "105133"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201109-224"
      },
      {
        "db": "NVD",
        "id": "CVE-2011-3321"
      }
    ]
  },
  "id": "VAR-201109-0223",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "IVD",
        "id": "7d7d7a11-463f-11e9-84c1-000c29342cb1"
      },
      {
        "db": "IVD",
        "id": "a57fd672-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-6876"
      },
      {
        "db": "VULHUB",
        "id": "VHN-51266"
      }
    ],
    "trust": 1.7353303000000002
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 1.0
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "7d7d7a11-463f-11e9-84c1-000c29342cb1"
      },
      {
        "db": "IVD",
        "id": "a57fd672-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-6876"
      }
    ]
  },
  "last_update_date": "2025-04-11T23:02:05.005000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "SIEMENS-SSA-460621",
        "trust": 0.8,
        "url": "http://cache.automation.siemens.com/dnl/jI/jI0NDY5AAAA_29054992_FAQ/Siemens_Security_Advisory_SSA-460621_V1_2.pdf"
      },
      {
        "title": "\u30b7\u30fc\u30e1\u30f3\u30b9\u30bd\u30ea\u30e5\u30fc\u30b7\u30e7\u30f3\u30d1\u30fc\u30c8\u30ca\u30fc ",
        "trust": 0.8,
        "url": "http://www.automation.siemens.com/automation/jp/ja/solutionpartner/pages/default.aspx"
      },
      {
        "title": "\u30b7\u30fc\u30e1\u30f3\u30b9\u30fb\u30b8\u30e3\u30d1\u30f3\u682a\u5f0f\u4f1a\u793e",
        "trust": 0.8,
        "url": "http://www.siemens.com/entry/jp/ja/"
      },
      {
        "title": "Patch for the Siemens SIMATIC WinCC Runtime Loader Buffer Overflow Vulnerability",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/43377"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2011-6876"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2011-002270"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-119",
        "trust": 1.9
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-51266"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2011-002270"
      },
      {
        "db": "NVD",
        "id": "CVE-2011-3321"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.6,
        "url": "http://www.us-cert.gov/control_systems/pdf/icsa-11-244-01.pdf"
      },
      {
        "trust": 1.7,
        "url": "http://support.automation.siemens.com/ww/view/en/29054992"
      },
      {
        "trust": 1.7,
        "url": "http://secunia.com/advisories/46011"
      },
      {
        "trust": 1.2,
        "url": "http://cache.automation.siemens.com/dnl/ji/ji0ndy5aaaa_29054992_faq/siemens_security_advisory_ssa-460621_v1_2.pdf"
      },
      {
        "trust": 1.1,
        "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/69803"
      },
      {
        "trust": 0.8,
        "url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2011-3321"
      },
      {
        "trust": 0.8,
        "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2011-3321"
      },
      {
        "trust": 0.6,
        "url": "http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-460621.pdf"
      },
      {
        "trust": 0.6,
        "url": "http://www.nsfocus.net/vulndb/17733"
      },
      {
        "trust": 0.1,
        "url": "http://secunia.com/vulnerability_scanning/corporate/trial/"
      },
      {
        "trust": 0.1,
        "url": "http://secunia.com/vulnerability_intelligence/"
      },
      {
        "trust": 0.1,
        "url": "http://secunia.com/advisories/secunia_security_advisories/"
      },
      {
        "trust": 0.1,
        "url": "http://secunia.com/vulnerability_scanning/corporate/wsus_sccm_3rd_third_party_patching/"
      },
      {
        "trust": 0.1,
        "url": "http://secunia.com/advisories/about_secunia_advisories/"
      },
      {
        "trust": 0.1,
        "url": "http://secunia.com/vulnerability_scanning/personal/"
      },
      {
        "trust": 0.1,
        "url": "http://secunia.com/advisories/46011/#comments"
      },
      {
        "trust": 0.1,
        "url": "http://support.automation.siemens.com/ww/llisapi.dll?func=cslib.csinfo\u0026lang=de\u0026objid=29054992\u0026caller=view"
      },
      {
        "trust": 0.1,
        "url": "http://secunia.com/sec_adv_unsubscribe/?email=packet%40packetstormsecurity.org"
      },
      {
        "trust": 0.1,
        "url": "https://ca.secunia.com/?page=viewadvisory\u0026vuln_id=46011"
      },
      {
        "trust": 0.1,
        "url": "http://secunia.com/advisories/46011/"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2011-6876"
      },
      {
        "db": "VULHUB",
        "id": "VHN-51266"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2011-002270"
      },
      {
        "db": "PACKETSTORM",
        "id": "105133"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201109-224"
      },
      {
        "db": "NVD",
        "id": "CVE-2011-3321"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "IVD",
        "id": "7d7d7a11-463f-11e9-84c1-000c29342cb1"
      },
      {
        "db": "IVD",
        "id": "a57fd672-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-6876"
      },
      {
        "db": "VULHUB",
        "id": "VHN-51266"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2011-002270"
      },
      {
        "db": "PACKETSTORM",
        "id": "105133"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201109-224"
      },
      {
        "db": "NVD",
        "id": "CVE-2011-3321"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2014-02-18T00:00:00",
        "db": "IVD",
        "id": "7d7d7a11-463f-11e9-84c1-000c29342cb1"
      },
      {
        "date": "2014-02-18T00:00:00",
        "db": "IVD",
        "id": "a57fd672-2354-11e6-abef-000c29c66e3d"
      },
      {
        "date": "2011-09-14T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2011-6876"
      },
      {
        "date": "2011-09-16T00:00:00",
        "db": "VULHUB",
        "id": "VHN-51266"
      },
      {
        "date": "2011-09-29T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2011-002270"
      },
      {
        "date": "2011-09-15T06:46:52",
        "db": "PACKETSTORM",
        "id": "105133"
      },
      {
        "date": "2011-09-16T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201109-224"
      },
      {
        "date": "2011-09-16T12:35:26.450000",
        "db": "NVD",
        "id": "CVE-2011-3321"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2016-09-13T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2011-6876"
      },
      {
        "date": "2017-08-29T00:00:00",
        "db": "VULHUB",
        "id": "VHN-51266"
      },
      {
        "date": "2011-09-29T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2011-002270"
      },
      {
        "date": "2011-09-20T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201109-224"
      },
      {
        "date": "2025-04-11T00:51:21.963000",
        "db": "NVD",
        "id": "CVE-2011-3321"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201109-224"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Siemens SIMATIC WinCC Runtime Loader Buffer Overflow Vulnerability",
    "sources": [
      {
        "db": "IVD",
        "id": "7d7d7a11-463f-11e9-84c1-000c29342cb1"
      },
      {
        "db": "IVD",
        "id": "a57fd672-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-6876"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201109-224"
      }
    ],
    "trust": 1.6
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Buffer overflow",
    "sources": [
      {
        "db": "IVD",
        "id": "7d7d7a11-463f-11e9-84c1-000c29342cb1"
      },
      {
        "db": "IVD",
        "id": "a57fd672-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201109-224"
      }
    ],
    "trust": 1.0
  }
}

VAR-201202-0005

Vulnerability from variot - Updated: 2025-04-11 22:53

Buffer overflow in the Advantech ADAM OLE for Process Control (OPC) Server ActiveX control in ADAM OPC Server before 3.01.012, Modbus RTU OPC Server before 3.01.010, and Modbus TCP OPC Server before 3.01.010 allows remote attackers to execute arbitrary code via unspecified vectors. Siemens SIMATIC WinCC is a multi-user system that provides complete monitoring and data acquisition (SCADA) functionality for the industrial sector, from single-user systems to redundant server and remote web client solutions. A memory corruption vulnerability exists in Siemens SIMATIC WinCC Flexible. Due to an unspecified error in the tag emulator, an attacker can cause memory corruption by opening a specially crafted file, and the exploit can successfully execute arbitrary code. Advantech ADAM OPC Server is a Taiwanese industrial device server interface. Advantech ADAM OPC Server is prone to a remote buffer-overflow vulnerability because it fails to sufficiently validate user-supplied data. This issue affects an unspecified ActiveX control. Failed exploit attempts will likely result in denial-of-service conditions. The following versions are affected: The following products are affected: ProTool 6.0 SP3 WinCC flexible 2004 WinCC flexible 2005 WinCC flexible 2005 SP1 WinCC flexible 2007 WinCC flexible 2008 WinCC flexible 2008 SP1 WinCC flexible 2008 SP2. The following products are affected: Siemens SIMATIC WinCC flexible Runtime Siemens SIMATIC WinCC (TIA Portal) Runtime Advanced. Successful exploitation of the vulnerability can execute arbitrary code. A failed attack may cause a denial of service.

The vulnerability are reported in versions 2005 SP1, 2007, 2008, 2008 SP1, and 2008 SP2. Please see vendor's advisory for details.

PROVIDED AND/OR DISCOVERED BY: Billy Rios and Terry McCorkle via ICS-CERT. ----------------------------------------------------------------------

Ovum says ad hoc tools are out-dated. The best practice approach? Fast vulnerability intelligence, threat handling, and setup in one tool.

Read the new report on the Secunia VIM: http://secunia.com/products/corporate/vim/ovum_2011_request/


TITLE: Advantech OPC Server ADAM ActiveX Control Buffer Overflow Vulnerability

SECUNIA ADVISORY ID: SA46775

VERIFY ADVISORY: Secunia.com http://secunia.com/advisories/46775/ Customer Area (Credentials Required) https://ca.secunia.com/?page=viewadvisory&vuln_id=46775

RELEASE DATE: 2011-11-07

DISCUSS ADVISORY: http://secunia.com/advisories/46775/#comments

AVAILABLE ON SITE AND IN CUSTOMER AREA: * Last Update * Popularity * Comments * Criticality Level * Impact * Where * Solution Status * Operating System / Software * CVE Reference(s)

http://secunia.com/advisories/46775/

ONLY AVAILABLE IN CUSTOMER AREA: * Authentication Level * Report Reliability * Secunia PoC * Secunia Analysis * Systems Affected * Approve Distribution * Remediation Status * Secunia CVSS Score * CVSS

https://ca.secunia.com/?page=viewadvisory&vuln_id=46775

ONLY AVAILABLE WITH SECUNIA CSI AND SECUNIA PSI: * AUTOMATED SCANNING

http://secunia.com/vulnerability_scanning/personal/ http://secunia.com/vulnerability_scanning/corporate/wsus_sccm_3rd_third_party_patching/

DESCRIPTION: A vulnerability has been reported in Advantech OPC Server, which can be exploited by malicious people to compromise a user's system.

The vulnerability is reported in the following components: * Advantech ADAM OPC Server versions prior to V3.01.012. * Advantech Modbus RTU OPC Server versions prior to V3.01.010. * Advantech Modbus TCP OPC Server versions prior to V3.01.010.

SOLUTION: Reportedly a patch has been released. Contact the vendor for further information.

PROVIDED AND/OR DISCOVERED BY: ICS-CERT credits Security Research and Service Institute Information and Communication Security Technology Center (ICST).

ORIGINAL ADVISORY: ICS-CERT: http://www.us-cert.gov/control_systems/pdf/ICSA-11-279-01.pdf

OTHER REFERENCES: Further details available in Customer Area: http://secunia.com/vulnerability_intelligence/

DEEP LINKS: Further details available in Customer Area: http://secunia.com/vulnerability_intelligence/

EXTENDED DESCRIPTION: Further details available in Customer Area: http://secunia.com/vulnerability_intelligence/

EXTENDED SOLUTION: Further details available in Customer Area: http://secunia.com/vulnerability_intelligence/

EXPLOIT: Further details available in Customer Area: http://secunia.com/vulnerability_intelligence/


About: This Advisory was delivered by Secunia as a free service to help private users keeping their systems up to date against the latest vulnerabilities.

Subscribe: http://secunia.com/advisories/secunia_security_advisories/

Definitions: (Criticality, Where etc.) http://secunia.com/advisories/about_secunia_advisories/

Please Note: Secunia recommends that you verify all advisories you receive by clicking the link. Secunia NEVER sends attached files with advisories. Secunia does not advise people to install third party patches, only use those supplied by the vendor.


Unsubscribe: Secunia Security Advisories http://secunia.com/sec_adv_unsubscribe/?email=packet%40packetstormsecurity.org


Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201202-0005",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "simatic wincc flexible",
        "scope": "eq",
        "trust": 1.1,
        "vendor": "siemens",
        "version": "2005"
      },
      {
        "model": "adam opc server",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "advantech",
        "version": "3.01.011"
      },
      {
        "model": "modbus rtu opc server",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "advantech",
        "version": "3.01.010"
      },
      {
        "model": "modbus tcp opc server",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "advantech",
        "version": "3.01.09"
      },
      {
        "model": "protool sp3",
        "scope": "eq",
        "trust": 0.9,
        "vendor": "siemens",
        "version": "6.0"
      },
      {
        "model": "simatic wincc flexible sp2",
        "scope": "eq",
        "trust": 0.9,
        "vendor": "siemens",
        "version": "2008"
      },
      {
        "model": "simatic wincc flexible sp1",
        "scope": "eq",
        "trust": 0.9,
        "vendor": "siemens",
        "version": "2008"
      },
      {
        "model": "simatic wincc flexible",
        "scope": "eq",
        "trust": 0.9,
        "vendor": "siemens",
        "version": "2008"
      },
      {
        "model": "simatic wincc flexible",
        "scope": "eq",
        "trust": 0.9,
        "vendor": "siemens",
        "version": "2007"
      },
      {
        "model": "simatic wincc flexible sp1",
        "scope": "eq",
        "trust": 0.9,
        "vendor": "siemens",
        "version": "2005"
      },
      {
        "model": "adam opc server",
        "scope": "lt",
        "trust": 0.8,
        "vendor": "advantech",
        "version": "3.01.012"
      },
      {
        "model": "modbus rtu opc server",
        "scope": "lt",
        "trust": 0.8,
        "vendor": "advantech",
        "version": "3.01.010"
      },
      {
        "model": "modbus tcp opc server",
        "scope": "lt",
        "trust": 0.8,
        "vendor": "advantech",
        "version": "3.01.010"
      },
      {
        "model": "modbus tcp opc server",
        "scope": null,
        "trust": 0.6,
        "vendor": "advantech",
        "version": null
      },
      {
        "model": "modbus rtu opc server",
        "scope": null,
        "trust": 0.6,
        "vendor": "advantech",
        "version": null
      },
      {
        "model": "adam opc server",
        "scope": null,
        "trust": 0.6,
        "vendor": "advantech",
        "version": null
      },
      {
        "model": "modbus rtu opc server",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "advantech",
        "version": "3.01.010"
      },
      {
        "model": "modbus tcp opc server",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "advantech",
        "version": "3.01.09"
      },
      {
        "model": "adam opc server",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "advantech",
        "version": "3.01.011"
      },
      {
        "model": "modbus tcp opc server",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "advantech",
        "version": "0"
      },
      {
        "model": "modbus rtu opc server",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "advantech",
        "version": "0"
      },
      {
        "model": "adam opc server",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "advantech",
        "version": "0"
      },
      {
        "model": "modbus rtu opc server",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "advantech",
        "version": "3.01.010"
      },
      {
        "model": "modbus tcp opc server",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "advantech",
        "version": "3.01.010"
      },
      {
        "model": "adam opc server",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "advantech",
        "version": "3.01.012"
      },
      {
        "model": "simatic wincc flexible",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "2004"
      },
      {
        "model": "simatic wincc flexible runtime",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic wincc runtime advanced",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "adam opc server",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "modbus rtu opc server",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "modbus tcp opc server",
        "version": "*"
      },
      {
        "model": "protool sp3",
        "scope": "eq",
        "trust": 0.2,
        "vendor": "siemens",
        "version": "6.0*"
      },
      {
        "model": "simatic wincc flexible sp2",
        "scope": "eq",
        "trust": 0.2,
        "vendor": "siemens",
        "version": "2008*"
      },
      {
        "model": "simatic wincc flexible sp1",
        "scope": "eq",
        "trust": 0.2,
        "vendor": "siemens",
        "version": "2008*"
      },
      {
        "model": "simatic wincc flexible",
        "scope": "eq",
        "trust": 0.2,
        "vendor": "siemens",
        "version": "2008*"
      },
      {
        "model": "simatic wincc flexible",
        "scope": "eq",
        "trust": 0.2,
        "vendor": "siemens",
        "version": "2007*"
      },
      {
        "model": "simatic wincc flexible sp1",
        "scope": "eq",
        "trust": 0.2,
        "vendor": "siemens",
        "version": "2005*"
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "1a544d94-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "IVD",
        "id": "5119408c-1f8a-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-3471"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-4690"
      },
      {
        "db": "BID",
        "id": "50529"
      },
      {
        "db": "BID",
        "id": "49405"
      },
      {
        "db": "BID",
        "id": "49479"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001544"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201111-163"
      },
      {
        "db": "NVD",
        "id": "CVE-2011-1914"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/a:advantech:adam_opc_server",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/a:advantech:modbus_rtu_opc_server",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/a:advantech:modbus_tcp_opc_server",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001544"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "CERT and ICST",
    "sources": [
      {
        "db": "BID",
        "id": "50529"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201111-163"
      }
    ],
    "trust": 0.9
  },
  "cve": "CVE-2011-1914",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "CVE-2011-1914",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 1.0,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "Low",
            "accessVector": "Network",
            "authentication": "None",
            "author": "NVD",
            "availabilityImpact": "Partial",
            "baseScore": 7.5,
            "confidentialityImpact": "Partial",
            "exploitabilityScore": null,
            "id": "CVE-2011-1914",
            "impactScore": null,
            "integrityImpact": "Partial",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "High",
            "trust": 0.8,
            "userInteractionRequired": null,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "IVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "1a544d94-2354-11e6-abef-000c29c66e3d",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.2,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.9 [IVD]"
          },
          {
            "accessComplexity": null,
            "accessVector": null,
            "authentication": null,
            "author": "IVD",
            "availabilityImpact": null,
            "baseScore": null,
            "confidentialityImpact": null,
            "exploitabilityScore": null,
            "id": "5119408c-1f8a-11e6-abef-000c29c66e3d",
            "impactScore": null,
            "integrityImpact": null,
            "severity": null,
            "trust": 0.2,
            "vectorString": null,
            "version": "unknown"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "VHN-49859",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.1,
            "vectorString": "AV:N/AC:L/AU:N/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2011-1914",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "NVD",
            "id": "CVE-2011-1914",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201111-163",
            "trust": 0.6,
            "value": "CRITICAL"
          },
          {
            "author": "IVD",
            "id": "1a544d94-2354-11e6-abef-000c29c66e3d",
            "trust": 0.2,
            "value": "CRITICAL"
          },
          {
            "author": "IVD",
            "id": "5119408c-1f8a-11e6-abef-000c29c66e3d",
            "trust": 0.2,
            "value": "HIGH"
          },
          {
            "author": "VULHUB",
            "id": "VHN-49859",
            "trust": 0.1,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "1a544d94-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "IVD",
        "id": "5119408c-1f8a-11e6-abef-000c29c66e3d"
      },
      {
        "db": "VULHUB",
        "id": "VHN-49859"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001544"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201111-163"
      },
      {
        "db": "NVD",
        "id": "CVE-2011-1914"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Buffer overflow in the Advantech ADAM OLE for Process Control (OPC) Server ActiveX control in ADAM OPC Server before 3.01.012, Modbus RTU OPC Server before 3.01.010, and Modbus TCP OPC Server before 3.01.010 allows remote attackers to execute arbitrary code via unspecified vectors. Siemens SIMATIC WinCC is a multi-user system that provides complete monitoring and data acquisition (SCADA) functionality for the industrial sector, from single-user systems to redundant server and remote web client solutions. A memory corruption vulnerability exists in Siemens SIMATIC WinCC Flexible. Due to an unspecified error in the tag emulator, an attacker can cause memory corruption by opening a specially crafted file, and the exploit can successfully execute arbitrary code. Advantech ADAM OPC Server is a Taiwanese industrial device server interface. Advantech ADAM OPC Server is prone to a remote buffer-overflow vulnerability because it fails to sufficiently validate user-supplied data. This issue affects an unspecified ActiveX control. Failed exploit attempts will likely result in denial-of-service conditions. \nThe following versions are affected:\nThe following products are affected:\nProTool 6.0 SP3\nWinCC flexible 2004\nWinCC flexible 2005\nWinCC flexible 2005 SP1\nWinCC flexible 2007\nWinCC flexible 2008\nWinCC flexible 2008 SP1\nWinCC flexible 2008 SP2. \nThe following products are affected:\nSiemens SIMATIC WinCC flexible Runtime\nSiemens SIMATIC WinCC (TIA Portal) Runtime Advanced. Successful exploitation of the vulnerability can execute arbitrary code. A failed attack may cause a denial of service. \n\nThe vulnerability are reported in versions 2005 SP1, 2007, 2008, 2008\nSP1, and 2008 SP2. Please see vendor\u0027s advisory for details. \n\nPROVIDED AND/OR DISCOVERED BY:\nBilly Rios and Terry McCorkle via ICS-CERT. ----------------------------------------------------------------------\n\nOvum says ad hoc tools are out-dated. The best practice approach?\nFast vulnerability intelligence, threat handling, and setup in one tool. \n\nRead the new report on the Secunia VIM:\nhttp://secunia.com/products/corporate/vim/ovum_2011_request/ \n\n----------------------------------------------------------------------\n\nTITLE:\nAdvantech OPC Server ADAM ActiveX Control Buffer Overflow\nVulnerability\n\nSECUNIA ADVISORY ID:\nSA46775\n\nVERIFY ADVISORY:\nSecunia.com\nhttp://secunia.com/advisories/46775/\nCustomer Area (Credentials Required)\nhttps://ca.secunia.com/?page=viewadvisory\u0026vuln_id=46775\n\nRELEASE DATE:\n2011-11-07\n\nDISCUSS ADVISORY:\nhttp://secunia.com/advisories/46775/#comments\n\nAVAILABLE ON SITE AND IN CUSTOMER AREA:\n * Last Update\n * Popularity\n * Comments\n * Criticality Level\n * Impact\n * Where\n * Solution Status\n * Operating System / Software\n * CVE Reference(s)\n\nhttp://secunia.com/advisories/46775/\n\nONLY AVAILABLE IN CUSTOMER AREA:\n * Authentication Level\n * Report Reliability\n * Secunia PoC\n * Secunia Analysis\n * Systems Affected\n * Approve Distribution\n * Remediation Status\n * Secunia CVSS Score\n * CVSS\n\nhttps://ca.secunia.com/?page=viewadvisory\u0026vuln_id=46775\n\nONLY AVAILABLE WITH SECUNIA CSI AND SECUNIA PSI:\n * AUTOMATED SCANNING\n\nhttp://secunia.com/vulnerability_scanning/personal/\nhttp://secunia.com/vulnerability_scanning/corporate/wsus_sccm_3rd_third_party_patching/\n\nDESCRIPTION:\nA vulnerability has been reported in Advantech OPC Server, which can\nbe exploited by malicious people to compromise a user\u0027s system. \n\nThe vulnerability is reported in the following components:\n* Advantech ADAM OPC Server versions prior to V3.01.012. \n* Advantech Modbus RTU OPC Server versions prior to V3.01.010. \n* Advantech Modbus TCP OPC Server versions prior to V3.01.010. \n\nSOLUTION:\nReportedly a patch has been released. Contact the vendor for further\ninformation. \n\nPROVIDED AND/OR DISCOVERED BY:\nICS-CERT credits Security Research and Service Institute Information\nand Communication Security Technology Center (ICST). \n\nORIGINAL ADVISORY:\nICS-CERT:\nhttp://www.us-cert.gov/control_systems/pdf/ICSA-11-279-01.pdf\n\nOTHER REFERENCES:\nFurther details available in Customer Area:\nhttp://secunia.com/vulnerability_intelligence/\n\nDEEP LINKS:\nFurther details available in Customer Area:\nhttp://secunia.com/vulnerability_intelligence/\n\nEXTENDED DESCRIPTION:\nFurther details available in Customer Area:\nhttp://secunia.com/vulnerability_intelligence/\n\nEXTENDED SOLUTION:\nFurther details available in Customer Area:\nhttp://secunia.com/vulnerability_intelligence/\n\nEXPLOIT:\nFurther details available in Customer Area:\nhttp://secunia.com/vulnerability_intelligence/\n\n----------------------------------------------------------------------\n\nAbout:\nThis Advisory was delivered by Secunia as a free service to help\nprivate users keeping their systems up to date against the latest\nvulnerabilities. \n\nSubscribe:\nhttp://secunia.com/advisories/secunia_security_advisories/\n\nDefinitions: (Criticality, Where etc.)\nhttp://secunia.com/advisories/about_secunia_advisories/\n\n\nPlease Note:\nSecunia recommends that you verify all advisories you receive by\nclicking the link. \nSecunia NEVER sends attached files with advisories. \nSecunia does not advise people to install third party patches, only\nuse those supplied by the vendor. \n\n----------------------------------------------------------------------\n\nUnsubscribe: Secunia Security Advisories\nhttp://secunia.com/sec_adv_unsubscribe/?email=packet%40packetstormsecurity.org\n\n----------------------------------------------------------------------\n\n\n",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2011-1914"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001544"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-3471"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-4690"
      },
      {
        "db": "BID",
        "id": "50529"
      },
      {
        "db": "BID",
        "id": "49405"
      },
      {
        "db": "BID",
        "id": "49479"
      },
      {
        "db": "IVD",
        "id": "1a544d94-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "IVD",
        "id": "5119408c-1f8a-11e6-abef-000c29c66e3d"
      },
      {
        "db": "VULHUB",
        "id": "VHN-49859"
      },
      {
        "db": "PACKETSTORM",
        "id": "104678"
      },
      {
        "db": "PACKETSTORM",
        "id": "106765"
      }
    ],
    "trust": 4.14
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2011-1914",
        "trust": 3.9
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-11-279-01",
        "trust": 3.5
      },
      {
        "db": "BID",
        "id": "49405",
        "trust": 1.5
      },
      {
        "db": "BID",
        "id": "50529",
        "trust": 1.0
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201111-163",
        "trust": 0.9
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-4690",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-3471",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001544",
        "trust": 0.8
      },
      {
        "db": "SECUNIA",
        "id": "46775",
        "trust": 0.8
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-11-175-02",
        "trust": 0.7
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201108-546",
        "trust": 0.6
      },
      {
        "db": "NSFOCUS",
        "id": "17671",
        "trust": 0.6
      },
      {
        "db": "NSFOCUS",
        "id": "18130",
        "trust": 0.6
      },
      {
        "db": "BID",
        "id": "49479",
        "trust": 0.4
      },
      {
        "db": "IVD",
        "id": "1A544D94-2354-11E6-ABEF-000C29C66E3D",
        "trust": 0.2
      },
      {
        "db": "IVD",
        "id": "5119408C-1F8A-11E6-ABEF-000C29C66E3D",
        "trust": 0.2
      },
      {
        "db": "SECUNIA",
        "id": "45770",
        "trust": 0.2
      },
      {
        "db": "VULHUB",
        "id": "VHN-49859",
        "trust": 0.1
      },
      {
        "db": "PACKETSTORM",
        "id": "104678",
        "trust": 0.1
      },
      {
        "db": "PACKETSTORM",
        "id": "106765",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "1a544d94-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "IVD",
        "id": "5119408c-1f8a-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-3471"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-4690"
      },
      {
        "db": "VULHUB",
        "id": "VHN-49859"
      },
      {
        "db": "BID",
        "id": "50529"
      },
      {
        "db": "BID",
        "id": "49405"
      },
      {
        "db": "BID",
        "id": "49479"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001544"
      },
      {
        "db": "PACKETSTORM",
        "id": "104678"
      },
      {
        "db": "PACKETSTORM",
        "id": "106765"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201108-546"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201111-163"
      },
      {
        "db": "NVD",
        "id": "CVE-2011-1914"
      }
    ]
  },
  "id": "VAR-201202-0005",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "IVD",
        "id": "1a544d94-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "IVD",
        "id": "5119408c-1f8a-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-3471"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-4690"
      },
      {
        "db": "VULHUB",
        "id": "VHN-49859"
      }
    ],
    "trust": 2.386455681111111
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 1.6
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "1a544d94-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "IVD",
        "id": "5119408c-1f8a-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-3471"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-4690"
      }
    ]
  },
  "last_update_date": "2025-04-11T22:53:59.415000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "OPC Server",
        "trust": 0.8,
        "url": "http://www.advantech.co.jp/products/OPC-Server/mod_7396B07A-5CAE-463C-947B-2EED9E3A2B79.aspx"
      },
      {
        "title": "\u30d1\u30fc\u30c8\u30ca\u30fc\u60c5\u5831",
        "trust": 0.8,
        "url": "http://www.advantech.co.jp/support-AJP/distributors.asp"
      },
      {
        "title": "Top Page",
        "trust": 0.8,
        "url": "http://www.advantech.co.jp/"
      },
      {
        "title": "Patch for Siemens SIMATIC WinCC Flexible Tag Simulator Memory Corruption Vulnerability",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/4976"
      },
      {
        "title": "Advantech ADAM OPC Server ActiveX Control Buffer Overflow Vulnerability Patch",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/5790"
      },
      {
        "title": "ModbusTCP OPC Server_3_01_013",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=42708"
      },
      {
        "title": "ADAM OPC Server_3_01_012",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=42710"
      },
      {
        "title": "ModbusRTU OPC Server_3_01_010",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=42709"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2011-3471"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-4690"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001544"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201111-163"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-119",
        "trust": 1.9
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-49859"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001544"
      },
      {
        "db": "NVD",
        "id": "CVE-2011-1914"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 3.5,
        "url": "http://www.us-cert.gov/control_systems/pdf/icsa-11-279-01.pdf"
      },
      {
        "trust": 0.8,
        "url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2011-1914"
      },
      {
        "trust": 0.8,
        "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2011-1914"
      },
      {
        "trust": 0.7,
        "url": "http://www.us-cert.gov/control_systems/pdf/icsa-11-175-02.pdf"
      },
      {
        "trust": 0.7,
        "url": "http://support.automation.siemens.com/ww/llisapi.dll?func=cslib.csinfo\u0026lang=en\u0026objid=50182361"
      },
      {
        "trust": 0.6,
        "url": "http://www.securityfocus.com/bid/49405http"
      },
      {
        "trust": 0.6,
        "url": "http://www.securityfocus.com/bid/49405"
      },
      {
        "trust": 0.6,
        "url": "http://secunia.com/advisories/46775"
      },
      {
        "trust": 0.6,
        "url": "http://www.securityfocus.com/bid/50529"
      },
      {
        "trust": 0.6,
        "url": "http://www.nsfocus.net/vulndb/18130"
      },
      {
        "trust": 0.6,
        "url": "http://www.nsfocus.net/vulndb/17671"
      },
      {
        "trust": 0.3,
        "url": "http://webaccess.advantech.com/product.php"
      },
      {
        "trust": 0.2,
        "url": "http://secunia.com/vulnerability_scanning/corporate/wsus_sccm_3rd_third_party_patching/"
      },
      {
        "trust": 0.2,
        "url": "http://secunia.com/vulnerability_intelligence/"
      },
      {
        "trust": 0.2,
        "url": "http://secunia.com/advisories/secunia_security_advisories/"
      },
      {
        "trust": 0.2,
        "url": "http://secunia.com/vulnerability_scanning/personal/"
      },
      {
        "trust": 0.2,
        "url": "http://secunia.com/sec_adv_unsubscribe/?email=packet%40packetstormsecurity.org"
      },
      {
        "trust": 0.2,
        "url": "http://secunia.com/advisories/about_secunia_advisories/"
      },
      {
        "trust": 0.1,
        "url": "https://ca.secunia.com/?page=viewadvisory\u0026vuln_id=45770"
      },
      {
        "trust": 0.1,
        "url": "http://secunia.com/advisories/45770/#comments"
      },
      {
        "trust": 0.1,
        "url": "http://secunia.com/blog/242"
      },
      {
        "trust": 0.1,
        "url": "http://secunia.com/advisories/45770/"
      },
      {
        "trust": 0.1,
        "url": "https://ca.secunia.com/?page=viewadvisory\u0026vuln_id=46775"
      },
      {
        "trust": 0.1,
        "url": "http://secunia.com/products/corporate/vim/ovum_2011_request/"
      },
      {
        "trust": 0.1,
        "url": "http://secunia.com/advisories/46775/"
      },
      {
        "trust": 0.1,
        "url": "http://secunia.com/advisories/46775/#comments"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2011-3471"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-4690"
      },
      {
        "db": "VULHUB",
        "id": "VHN-49859"
      },
      {
        "db": "BID",
        "id": "50529"
      },
      {
        "db": "BID",
        "id": "49405"
      },
      {
        "db": "BID",
        "id": "49479"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001544"
      },
      {
        "db": "PACKETSTORM",
        "id": "104678"
      },
      {
        "db": "PACKETSTORM",
        "id": "106765"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201108-546"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201111-163"
      },
      {
        "db": "NVD",
        "id": "CVE-2011-1914"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "IVD",
        "id": "1a544d94-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "IVD",
        "id": "5119408c-1f8a-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-3471"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-4690"
      },
      {
        "db": "VULHUB",
        "id": "VHN-49859"
      },
      {
        "db": "BID",
        "id": "50529"
      },
      {
        "db": "BID",
        "id": "49405"
      },
      {
        "db": "BID",
        "id": "49479"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001544"
      },
      {
        "db": "PACKETSTORM",
        "id": "104678"
      },
      {
        "db": "PACKETSTORM",
        "id": "106765"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201108-546"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201111-163"
      },
      {
        "db": "NVD",
        "id": "CVE-2011-1914"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2011-11-07T00:00:00",
        "db": "IVD",
        "id": "1a544d94-2354-11e6-abef-000c29c66e3d"
      },
      {
        "date": "2011-09-02T00:00:00",
        "db": "IVD",
        "id": "5119408c-1f8a-11e6-abef-000c29c66e3d"
      },
      {
        "date": "2011-09-02T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2011-3471"
      },
      {
        "date": "2011-11-07T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2011-4690"
      },
      {
        "date": "2012-02-21T00:00:00",
        "db": "VULHUB",
        "id": "VHN-49859"
      },
      {
        "date": "2011-11-04T00:00:00",
        "db": "BID",
        "id": "50529"
      },
      {
        "date": "2011-09-01T00:00:00",
        "db": "BID",
        "id": "49405"
      },
      {
        "date": "2011-09-06T00:00:00",
        "db": "BID",
        "id": "49479"
      },
      {
        "date": "2012-02-23T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2012-001544"
      },
      {
        "date": "2011-09-01T12:46:24",
        "db": "PACKETSTORM",
        "id": "104678"
      },
      {
        "date": "2011-11-09T12:04:37",
        "db": "PACKETSTORM",
        "id": "106765"
      },
      {
        "date": "1900-01-01T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201108-546"
      },
      {
        "date": "1900-01-01T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201111-163"
      },
      {
        "date": "2012-02-21T13:31:55.877000",
        "db": "NVD",
        "id": "CVE-2011-1914"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2011-09-02T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2011-3471"
      },
      {
        "date": "2011-11-07T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2011-4690"
      },
      {
        "date": "2012-02-23T00:00:00",
        "db": "VULHUB",
        "id": "VHN-49859"
      },
      {
        "date": "2011-11-04T00:00:00",
        "db": "BID",
        "id": "50529"
      },
      {
        "date": "2011-09-01T00:00:00",
        "db": "BID",
        "id": "49405"
      },
      {
        "date": "2011-09-06T00:00:00",
        "db": "BID",
        "id": "49479"
      },
      {
        "date": "2012-02-23T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2012-001544"
      },
      {
        "date": "2011-09-05T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201108-546"
      },
      {
        "date": "2011-11-08T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201111-163"
      },
      {
        "date": "2025-04-11T00:51:21.963000",
        "db": "NVD",
        "id": "CVE-2011-1914"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201108-546"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201111-163"
      }
    ],
    "trust": 1.2
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Advantech ADAM OPC Server ActiveX Control Buffer Overflow Vulnerability",
    "sources": [
      {
        "db": "IVD",
        "id": "1a544d94-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-4690"
      },
      {
        "db": "BID",
        "id": "50529"
      }
    ],
    "trust": 1.1
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Buffer overflow",
    "sources": [
      {
        "db": "IVD",
        "id": "1a544d94-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201111-163"
      }
    ],
    "trust": 0.8
  }
}

VAR-201202-0044

Vulnerability from variot - Updated: 2025-04-11 22:49

The HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime has an improperly selected default password for the administrator account, which makes it easier for remote attackers to obtain access via a brute-force approach involving many HTTP requests. Siemens SIMATIC WinCC is a multi-user system that provides complete monitoring and data acquisition (SCADA) functionality for the industrial sector, from single-user systems to redundant server and remote web client solutions. The default management password exists for multiple Siemens SIMATIC products. The default account password for the WEB interface is \"Administrator: 100\", and the password \"100\" can also be used for the VNC service. If the user changes the password containing special characters, the system will put the password. Reset to \"100\". The following products are affected by this vulnerability: SIMATIC WinCC Flexible 2004 through 2008 SP2SIMATIC WinCC V11, V11 SP1, and V11 SP2 SIMATIC HMI TP, OP, MP, Mobile, and Comfort Series Panels Successful exploits allow an attacker to log in with user or administrator privileges Affect the system. An attacker can exploit these issues to bypass intended security restrictions and gain access to the affected application. Successfully exploiting these issues may lead to further attacks. The Siemens SIMATIC HMI product family is used as the human-machine interface between the corresponding PLC and the operator

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201202-0044",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "simatic hmi panels",
        "scope": "eq",
        "trust": 2.4,
        "vendor": "siemens",
        "version": "mp"
      },
      {
        "model": "simatic hmi panels",
        "scope": "eq",
        "trust": 2.4,
        "vendor": "siemens",
        "version": "op"
      },
      {
        "model": "simatic hmi panels",
        "scope": "eq",
        "trust": 2.4,
        "vendor": "siemens",
        "version": "tp"
      },
      {
        "model": "simatic wincc flexible",
        "scope": "eq",
        "trust": 1.7,
        "vendor": "siemens",
        "version": "2008"
      },
      {
        "model": "simatic wincc flexible",
        "scope": "eq",
        "trust": 1.7,
        "vendor": "siemens",
        "version": "2007"
      },
      {
        "model": "simatic wincc flexible",
        "scope": "eq",
        "trust": 1.7,
        "vendor": "siemens",
        "version": "2005"
      },
      {
        "model": "simatic wincc flexible",
        "scope": "eq",
        "trust": 1.7,
        "vendor": "siemens",
        "version": "2004"
      },
      {
        "model": "simatic wincc",
        "scope": "eq",
        "trust": 1.7,
        "vendor": "siemens",
        "version": "v11"
      },
      {
        "model": "wincc flexible",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "2008"
      },
      {
        "model": "simatic hmi panels",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "comfort_panels"
      },
      {
        "model": "wincc runtime advanced",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "v11"
      },
      {
        "model": "wincc",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "v11"
      },
      {
        "model": "simatic hmi panels",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "mobile_panels"
      },
      {
        "model": "wincc flexible",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "2007"
      },
      {
        "model": "wincc flexible",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2004"
      },
      {
        "model": "wincc flexible runtime",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "wincc flexible",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2005"
      },
      {
        "model": "simatic wincc flexible sp1",
        "scope": "eq",
        "trust": 0.9,
        "vendor": "siemens",
        "version": "2008"
      },
      {
        "model": "simatic wincc flexible sp2",
        "scope": "eq",
        "trust": 0.9,
        "vendor": "siemens",
        "version": "2008"
      },
      {
        "model": "simatic wincc flexible sp1",
        "scope": "eq",
        "trust": 0.9,
        "vendor": "siemens",
        "version": "2005"
      },
      {
        "model": "simatic wincc flexible runtime",
        "scope": "eq",
        "trust": 0.9,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic hmi panels",
        "scope": "eq",
        "trust": 0.9,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic wincc sp2",
        "scope": "eq",
        "trust": 0.9,
        "vendor": "siemens",
        "version": "v11"
      },
      {
        "model": "simatic wincc sp1",
        "scope": "eq",
        "trust": 0.9,
        "vendor": "siemens",
        "version": "v11"
      },
      {
        "model": "simatic wincc",
        "scope": "eq",
        "trust": 0.9,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic hmi panels",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "siemens",
        "version": "comfort panels"
      },
      {
        "model": "simatic hmi panels",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "siemens",
        "version": "mobile panels"
      },
      {
        "model": "simatic wincc flexible rumtime",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic wincc runtime advanced",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "siemens",
        "version": "v11"
      },
      {
        "model": "wincc flexible runtime",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "wincc flexible",
        "version": "2004"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "wincc flexible",
        "version": "2005"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "wincc flexible",
        "version": "2007"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "wincc flexible",
        "version": "2008"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "wincc",
        "version": "v11"
      },
      {
        "model": "comfort panels",
        "scope": null,
        "trust": 0.2,
        "vendor": "simatic hmi panels",
        "version": null
      },
      {
        "model": "mobile panels",
        "scope": null,
        "trust": 0.2,
        "vendor": "simatic hmi panels",
        "version": null
      },
      {
        "model": "mp",
        "scope": null,
        "trust": 0.2,
        "vendor": "simatic hmi panels",
        "version": null
      },
      {
        "model": "op",
        "scope": null,
        "trust": 0.2,
        "vendor": "simatic hmi panels",
        "version": null
      },
      {
        "model": "tp",
        "scope": null,
        "trust": 0.2,
        "vendor": "simatic hmi panels",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "wincc runtime advanced",
        "version": "v11"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "wincc flexible runtime",
        "version": "*"
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "2875d28a-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5449"
      },
      {
        "db": "BID",
        "id": "51177"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001311"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201112-423"
      },
      {
        "db": "NVD",
        "id": "CVE-2011-4509"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/a:siemens:simatic_hmi_panels",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/a:siemens:simatic_wincc_%28tia_portal%29",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/a:siemens:wincc_flexible",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/a:siemens:wincc_flexible_runtime",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/a:siemens:wincc_runtime_advanced",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001311"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Billy Rios and Terry McCorkle",
    "sources": [
      {
        "db": "BID",
        "id": "51177"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201112-423"
      }
    ],
    "trust": 0.9
  },
  "cve": "CVE-2011-4509",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "CVE-2011-4509",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 1.8,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "IVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "2875d28a-2354-11e6-abef-000c29c66e3d",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.2,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.9 [IVD]"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "VHN-52454",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.1,
            "vectorString": "AV:N/AC:L/AU:N/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2011-4509",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "NVD",
            "id": "CVE-2011-4509",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201112-423",
            "trust": 0.6,
            "value": "CRITICAL"
          },
          {
            "author": "IVD",
            "id": "2875d28a-2354-11e6-abef-000c29c66e3d",
            "trust": 0.2,
            "value": "CRITICAL"
          },
          {
            "author": "VULHUB",
            "id": "VHN-52454",
            "trust": 0.1,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "2875d28a-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "VULHUB",
        "id": "VHN-52454"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001311"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201112-423"
      },
      {
        "db": "NVD",
        "id": "CVE-2011-4509"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "The HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime has an improperly selected default password for the administrator account, which makes it easier for remote attackers to obtain access via a brute-force approach involving many HTTP requests. Siemens SIMATIC WinCC is a multi-user system that provides complete monitoring and data acquisition (SCADA) functionality for the industrial sector, from single-user systems to redundant server and remote web client solutions. The default management password exists for multiple Siemens SIMATIC products. The default account password for the WEB interface is \\\"Administrator: 100\\\", and the password \\\"100\\\" can also be used for the VNC service. If the user changes the password containing special characters, the system will put the password. Reset to \\\"100\\\". The following products are affected by this vulnerability: SIMATIC WinCC Flexible 2004 through 2008 SP2SIMATIC WinCC V11, V11 SP1, and V11 SP2 SIMATIC HMI TP, OP, MP, Mobile, and Comfort Series Panels Successful exploits allow an attacker to log in with user or administrator privileges Affect the system. \nAn attacker can exploit these issues to bypass intended security   restrictions and gain access to the affected application.  Successfully   exploiting these issues may lead to further attacks. The Siemens SIMATIC HMI product family is used as the human-machine interface between the corresponding PLC and the operator",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2011-4509"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001311"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5449"
      },
      {
        "db": "BID",
        "id": "51177"
      },
      {
        "db": "IVD",
        "id": "2875d28a-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "VULHUB",
        "id": "VHN-52454"
      }
    ],
    "trust": 2.7
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2011-4509",
        "trust": 3.6
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-12-030-01",
        "trust": 2.5
      },
      {
        "db": "SIEMENS",
        "id": "SSA-345442",
        "trust": 1.7
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201112-423",
        "trust": 0.9
      },
      {
        "db": "BID",
        "id": "51177",
        "trust": 0.9
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5449",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001311",
        "trust": 0.8
      },
      {
        "db": "NSFOCUS",
        "id": "18390",
        "trust": 0.6
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-11-356-01",
        "trust": 0.3
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-12-030-01A",
        "trust": 0.3
      },
      {
        "db": "IVD",
        "id": "2875D28A-2354-11E6-ABEF-000C29C66E3D",
        "trust": 0.2
      },
      {
        "db": "VULHUB",
        "id": "VHN-52454",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "2875d28a-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5449"
      },
      {
        "db": "VULHUB",
        "id": "VHN-52454"
      },
      {
        "db": "BID",
        "id": "51177"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001311"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201112-423"
      },
      {
        "db": "NVD",
        "id": "CVE-2011-4509"
      }
    ]
  },
  "id": "VAR-201202-0044",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "IVD",
        "id": "2875d28a-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5449"
      },
      {
        "db": "VULHUB",
        "id": "VHN-52454"
      }
    ],
    "trust": 1.575178075
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "2875d28a-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5449"
      }
    ]
  },
  "last_update_date": "2025-04-11T22:49:48.693000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "SSA-345442",
        "trust": 0.8,
        "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf"
      },
      {
        "title": "\u30bd\u30ea\u30e5\u30fc\u30b7\u30e7\u30f3\u30d1\u30fc\u30c8\u30ca\u30fc",
        "trust": 0.8,
        "url": "http://www.automation.siemens.com/automation/jp/ja/solutionpartner/pages/default.aspx"
      },
      {
        "title": "Top Page",
        "trust": 0.8,
        "url": "http://www.siemens.com/entry/jp/ja/"
      },
      {
        "title": "Patch for multiple Siemens SIMATIC Product Verification Bypass Vulnerabilities (CNVD-2011-5449)",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/72709"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2011-5449"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001311"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-264",
        "trust": 1.9
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-52454"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001311"
      },
      {
        "db": "NVD",
        "id": "CVE-2011-4509"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.5,
        "url": "http://www.us-cert.gov/control_systems/pdf/icsa-12-030-01.pdf"
      },
      {
        "trust": 1.7,
        "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf"
      },
      {
        "trust": 0.8,
        "url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2011-4509"
      },
      {
        "trust": 0.8,
        "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2011-4509"
      },
      {
        "trust": 0.6,
        "url": "http://xs-sniper.com/blog/2011/12/20/the-siemens-simatic-remote-authentication-bypass-that-doesnt-exist/http"
      },
      {
        "trust": 0.6,
        "url": "http://www.securityfocus.com/bid/51177"
      },
      {
        "trust": 0.6,
        "url": "http://www.nsfocus.net/vulndb/18390"
      },
      {
        "trust": 0.3,
        "url": "http://www.automation.siemens.com/mcms/human-machine-interface/en/visualization-software/pages/default.aspx"
      },
      {
        "trust": 0.3,
        "url": "http://www.automation.siemens.com/mcms/human-machine-interface/en/visualization-software/wincc-flexible/wincc-flexible-runtime/user-interface/pages/default.aspx"
      },
      {
        "trust": 0.3,
        "url": "http://xs-sniper.com/blog/2011/12/20/the-siemens-simatic-remote-authentication-bypass-that-doesnt-exist/"
      },
      {
        "trust": 0.3,
        "url": "http://www.us-cert.gov/control_systems/pdf/icsa-12-030-01a.pdf"
      },
      {
        "trust": 0.3,
        "url": "http://www.us-cert.gov/control_systems/pdf/icsa-11-356-01.pdf"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2011-5449"
      },
      {
        "db": "VULHUB",
        "id": "VHN-52454"
      },
      {
        "db": "BID",
        "id": "51177"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001311"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201112-423"
      },
      {
        "db": "NVD",
        "id": "CVE-2011-4509"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "IVD",
        "id": "2875d28a-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5449"
      },
      {
        "db": "VULHUB",
        "id": "VHN-52454"
      },
      {
        "db": "BID",
        "id": "51177"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001311"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201112-423"
      },
      {
        "db": "NVD",
        "id": "CVE-2011-4509"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2011-12-26T00:00:00",
        "db": "IVD",
        "id": "2875d28a-2354-11e6-abef-000c29c66e3d"
      },
      {
        "date": "2011-12-26T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2011-5449"
      },
      {
        "date": "2012-02-03T00:00:00",
        "db": "VULHUB",
        "id": "VHN-52454"
      },
      {
        "date": "2011-12-22T00:00:00",
        "db": "BID",
        "id": "51177"
      },
      {
        "date": "2012-02-08T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2012-001311"
      },
      {
        "date": "1900-01-01T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201112-423"
      },
      {
        "date": "2012-02-03T20:55:01.297000",
        "db": "NVD",
        "id": "CVE-2011-4509"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2016-03-15T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2011-5449"
      },
      {
        "date": "2012-02-06T00:00:00",
        "db": "VULHUB",
        "id": "VHN-52454"
      },
      {
        "date": "2012-04-18T21:20:00",
        "db": "BID",
        "id": "51177"
      },
      {
        "date": "2012-02-08T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2012-001311"
      },
      {
        "date": "2011-12-26T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201112-423"
      },
      {
        "date": "2025-04-11T00:51:21.963000",
        "db": "NVD",
        "id": "CVE-2011-4509"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201112-423"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "plural  Siemens Product  HMI Web Vulnerability to gain access rights on the server",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001311"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "permissions and access control",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201112-423"
      }
    ],
    "trust": 0.6
  }
}

VAR-201202-0048

Vulnerability from variot - Updated: 2025-04-11 22:49

Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allow user-assisted remote attackers to execute arbitrary code via a crafted project file, related to the HMI web server and runtime loader. plural Siemens The product includes HMI Web An arbitrary code execution vulnerability exists due to a flaw in processing related to the server and runtime loader.Crafted by attackers project An arbitrary code may be executed via the file. Siemens SIMATIC is an automation software in a single engineering environment. A security vulnerability exists in the Siemens SIMATIC WinCC HMI web server. Social engineering is required to enable administrators to download files and execute them. SIMATIC Wincc Runtime Advanced is prone to a remote security vulnerability. Vulnerabilities exist in several versions of Siemens SIMATIC WinCC

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201202-0048",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "simatic hmi panels",
        "scope": "eq",
        "trust": 2.4,
        "vendor": "siemens",
        "version": "mp"
      },
      {
        "model": "simatic hmi panels",
        "scope": "eq",
        "trust": 2.4,
        "vendor": "siemens",
        "version": "op"
      },
      {
        "model": "simatic hmi panels",
        "scope": "eq",
        "trust": 2.4,
        "vendor": "siemens",
        "version": "tp"
      },
      {
        "model": "wincc flexible",
        "scope": "eq",
        "trust": 1.9,
        "vendor": "siemens",
        "version": "2008"
      },
      {
        "model": "wincc flexible",
        "scope": "eq",
        "trust": 1.9,
        "vendor": "siemens",
        "version": "2007"
      },
      {
        "model": "wincc",
        "scope": "eq",
        "trust": 1.9,
        "vendor": "siemens",
        "version": "v11"
      },
      {
        "model": "simatic hmi panels",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "comfort_panels"
      },
      {
        "model": "wincc runtime advanced",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "v11"
      },
      {
        "model": "simatic hmi panels",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "mobile_panels"
      },
      {
        "model": "simatic wincc flexible",
        "scope": "eq",
        "trust": 1.4,
        "vendor": "siemens",
        "version": "2008"
      },
      {
        "model": "simatic wincc flexible",
        "scope": "eq",
        "trust": 1.4,
        "vendor": "siemens",
        "version": "2007"
      },
      {
        "model": "simatic wincc flexible",
        "scope": "eq",
        "trust": 1.4,
        "vendor": "siemens",
        "version": "2005"
      },
      {
        "model": "simatic wincc flexible",
        "scope": "eq",
        "trust": 1.4,
        "vendor": "siemens",
        "version": "2004"
      },
      {
        "model": "simatic wincc",
        "scope": "eq",
        "trust": 1.4,
        "vendor": "siemens",
        "version": "v11"
      },
      {
        "model": "wincc flexible",
        "scope": "eq",
        "trust": 1.3,
        "vendor": "siemens",
        "version": "2005"
      },
      {
        "model": "wincc flexible",
        "scope": "eq",
        "trust": 1.3,
        "vendor": "siemens",
        "version": "2004"
      },
      {
        "model": "simatic wincc runtime advanced",
        "scope": "eq",
        "trust": 1.1,
        "vendor": "siemens",
        "version": "v11"
      },
      {
        "model": "wincc flexible runtime",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic hmi panels",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "siemens",
        "version": "comfort panels"
      },
      {
        "model": "simatic hmi panels",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "siemens",
        "version": "mobile panels"
      },
      {
        "model": "simatic wincc flexible rumtime",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic wincc flexible runtime",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic wincc runtime advanced",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic hmi panels",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic wincc",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "wincc flexible runtime",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "wincc flexible runtime",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic hmi panels tp",
        "scope": null,
        "trust": 0.3,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic hmi panels op",
        "scope": null,
        "trust": 0.3,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic hmi panels mp",
        "scope": null,
        "trust": 0.3,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic hmi panels mobile panels",
        "scope": null,
        "trust": 0.3,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic hmi panels comfort panels",
        "scope": null,
        "trust": 0.3,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "wincc flexible",
        "version": "2004"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "wincc flexible",
        "version": "2005"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "wincc flexible",
        "version": "2007"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "wincc flexible",
        "version": "2008"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "wincc",
        "version": "v11"
      },
      {
        "model": "comfort panels",
        "scope": null,
        "trust": 0.2,
        "vendor": "simatic hmi panels",
        "version": null
      },
      {
        "model": "mobile panels",
        "scope": null,
        "trust": 0.2,
        "vendor": "simatic hmi panels",
        "version": null
      },
      {
        "model": "mp",
        "scope": null,
        "trust": 0.2,
        "vendor": "simatic hmi panels",
        "version": null
      },
      {
        "model": "op",
        "scope": null,
        "trust": 0.2,
        "vendor": "simatic hmi panels",
        "version": null
      },
      {
        "model": "tp",
        "scope": null,
        "trust": 0.2,
        "vendor": "simatic hmi panels",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "wincc runtime advanced",
        "version": "v11"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "wincc flexible runtime",
        "version": "*"
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "28dd62b0-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2012-0463"
      },
      {
        "db": "BID",
        "id": "78355"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001315"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201202-088"
      },
      {
        "db": "NVD",
        "id": "CVE-2011-4513"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/a:siemens:simatic_hmi_panels",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/a:siemens:simatic_wincc_%28tia_portal%29",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/a:siemens:wincc_flexible",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/a:siemens:wincc_flexible_runtime",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/a:siemens:wincc_runtime_advanced",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001315"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Unknown",
    "sources": [
      {
        "db": "BID",
        "id": "78355"
      }
    ],
    "trust": 0.3
  },
  "cve": "CVE-2011-4513",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "CVE-2011-4513",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 1.8,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "IVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "28dd62b0-2354-11e6-abef-000c29c66e3d",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.2,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.9 [IVD]"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "VHN-52458",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.1,
            "vectorString": "AV:N/AC:L/AU:N/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2011-4513",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "NVD",
            "id": "CVE-2011-4513",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201202-088",
            "trust": 0.6,
            "value": "CRITICAL"
          },
          {
            "author": "IVD",
            "id": "28dd62b0-2354-11e6-abef-000c29c66e3d",
            "trust": 0.2,
            "value": "CRITICAL"
          },
          {
            "author": "VULHUB",
            "id": "VHN-52458",
            "trust": 0.1,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "28dd62b0-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "VULHUB",
        "id": "VHN-52458"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001315"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201202-088"
      },
      {
        "db": "NVD",
        "id": "CVE-2011-4513"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allow user-assisted remote attackers to execute arbitrary code via a crafted project file, related to the HMI web server and runtime loader. plural Siemens The product includes HMI Web An arbitrary code execution vulnerability exists due to a flaw in processing related to the server and runtime loader.Crafted by attackers project An arbitrary code may be executed via the file. Siemens SIMATIC is an automation software in a single engineering environment. A security vulnerability exists in the Siemens SIMATIC WinCC HMI web server. Social engineering is required to enable administrators to download files and execute them. SIMATIC Wincc Runtime Advanced is prone to a remote security vulnerability. Vulnerabilities exist in several versions of Siemens SIMATIC WinCC",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2011-4513"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001315"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2012-0463"
      },
      {
        "db": "BID",
        "id": "78355"
      },
      {
        "db": "IVD",
        "id": "28dd62b0-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "VULHUB",
        "id": "VHN-52458"
      }
    ],
    "trust": 2.7
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2011-4513",
        "trust": 3.6
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-12-030-01",
        "trust": 3.4
      },
      {
        "db": "SIEMENS",
        "id": "SSA-345442",
        "trust": 2.0
      },
      {
        "db": "CNVD",
        "id": "CNVD-2012-0463",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201202-088",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001315",
        "trust": 0.8
      },
      {
        "db": "BID",
        "id": "78355",
        "trust": 0.4
      },
      {
        "db": "IVD",
        "id": "28DD62B0-2354-11E6-ABEF-000C29C66E3D",
        "trust": 0.2
      },
      {
        "db": "VULHUB",
        "id": "VHN-52458",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "28dd62b0-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2012-0463"
      },
      {
        "db": "VULHUB",
        "id": "VHN-52458"
      },
      {
        "db": "BID",
        "id": "78355"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001315"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201202-088"
      },
      {
        "db": "NVD",
        "id": "CVE-2011-4513"
      }
    ]
  },
  "id": "VAR-201202-0048",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "IVD",
        "id": "28dd62b0-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2012-0463"
      },
      {
        "db": "VULHUB",
        "id": "VHN-52458"
      }
    ],
    "trust": 1.5188906333333334
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "28dd62b0-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2012-0463"
      }
    ]
  },
  "last_update_date": "2025-04-11T22:49:48.653000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "SSA-345442",
        "trust": 0.8,
        "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf"
      },
      {
        "title": "\u30bd\u30ea\u30e5\u30fc\u30b7\u30e7\u30f3\u30d1\u30fc\u30c8\u30ca\u30fc",
        "trust": 0.8,
        "url": "http://www.automation.siemens.com/automation/jp/ja/solutionpartner/pages/default.aspx"
      },
      {
        "title": "Top Page",
        "trust": 0.8,
        "url": "http://www.siemens.com/entry/jp/ja/"
      },
      {
        "title": "Patch for Siemens SIMATIC WinCC HMI Vulnerability (CNVD-2012-0463)",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/9061"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2012-0463"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001315"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "NVD-CWE-noinfo",
        "trust": 1.0
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2011-4513"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 3.4,
        "url": "http://www.us-cert.gov/control_systems/pdf/icsa-12-030-01.pdf"
      },
      {
        "trust": 2.0,
        "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf"
      },
      {
        "trust": 0.8,
        "url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2011-4513"
      },
      {
        "trust": 0.8,
        "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2011-4513"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2012-0463"
      },
      {
        "db": "VULHUB",
        "id": "VHN-52458"
      },
      {
        "db": "BID",
        "id": "78355"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001315"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201202-088"
      },
      {
        "db": "NVD",
        "id": "CVE-2011-4513"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "IVD",
        "id": "28dd62b0-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2012-0463"
      },
      {
        "db": "VULHUB",
        "id": "VHN-52458"
      },
      {
        "db": "BID",
        "id": "78355"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001315"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201202-088"
      },
      {
        "db": "NVD",
        "id": "CVE-2011-4513"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2012-02-07T00:00:00",
        "db": "IVD",
        "id": "28dd62b0-2354-11e6-abef-000c29c66e3d"
      },
      {
        "date": "2012-02-07T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2012-0463"
      },
      {
        "date": "2012-02-03T00:00:00",
        "db": "VULHUB",
        "id": "VHN-52458"
      },
      {
        "date": "2012-02-03T00:00:00",
        "db": "BID",
        "id": "78355"
      },
      {
        "date": "2012-02-08T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2012-001315"
      },
      {
        "date": "2012-02-07T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201202-088"
      },
      {
        "date": "2012-02-03T20:55:01.513000",
        "db": "NVD",
        "id": "CVE-2011-4513"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2012-02-07T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2012-0463"
      },
      {
        "date": "2012-02-06T00:00:00",
        "db": "VULHUB",
        "id": "VHN-52458"
      },
      {
        "date": "2012-02-03T00:00:00",
        "db": "BID",
        "id": "78355"
      },
      {
        "date": "2012-02-08T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2012-001315"
      },
      {
        "date": "2012-02-13T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201202-088"
      },
      {
        "date": "2025-04-11T00:51:21.963000",
        "db": "NVD",
        "id": "CVE-2011-4513"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201202-088"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "plural  Siemens Vulnerabilities in products that allow arbitrary code execution",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001315"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "lack of information",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201202-088"
      }
    ],
    "trust": 0.6
  }
}

VAR-201202-0046

Vulnerability from variot - Updated: 2025-04-11 22:49

Cross-site scripting (XSS) vulnerability in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allows remote attackers to inject arbitrary web script or HTML via unspecified vectors, a different vulnerability than CVE-2011-4510. plural Siemens Product HMI Web The server contains a cross-site scripting vulnerability. This vulnerability is CVE-2011-4510 This is a different vulnerability.By any third party, Web Script or HTML May be inserted. Siemens SIMATIC is an automation software in a single engineering environment. The SIMATIC HMI Smart Options web server has two separate cross-site scripting attacks that allow elevation of privilege, stealing data or corrupting services. SIMATIC HMI is prone to multiple unspecified cross-site scripting vulnerabilities because it fails to properly sanitize user-supplied input. An attacker may leverage these issues to execute arbitrary script code in the browser of an unsuspecting user in the context of the affected site. This can allow the attacker to steal cookie-based authentication credentials and launch other attacks

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201202-0046",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "simatic hmi panels",
        "scope": "eq",
        "trust": 2.4,
        "vendor": "siemens",
        "version": "mp"
      },
      {
        "model": "simatic hmi panels",
        "scope": "eq",
        "trust": 2.4,
        "vendor": "siemens",
        "version": "op"
      },
      {
        "model": "simatic hmi panels",
        "scope": "eq",
        "trust": 2.4,
        "vendor": "siemens",
        "version": "tp"
      },
      {
        "model": "simatic hmi panels",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "comfort_panels"
      },
      {
        "model": "wincc runtime advanced",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "v11"
      },
      {
        "model": "wincc",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "v11"
      },
      {
        "model": "simatic hmi panels",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "mobile_panels"
      },
      {
        "model": "simatic wincc flexible",
        "scope": "eq",
        "trust": 1.4,
        "vendor": "siemens",
        "version": "2007"
      },
      {
        "model": "simatic wincc flexible",
        "scope": "eq",
        "trust": 1.4,
        "vendor": "siemens",
        "version": "2005"
      },
      {
        "model": "simatic wincc flexible",
        "scope": "eq",
        "trust": 1.4,
        "vendor": "siemens",
        "version": "2004"
      },
      {
        "model": "wincc flexible",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2004"
      },
      {
        "model": "wincc flexible runtime",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "wincc flexible",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2007"
      },
      {
        "model": "wincc",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "v11"
      },
      {
        "model": "wincc flexible",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2005"
      },
      {
        "model": "wincc flexible",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2008"
      },
      {
        "model": "simatic hmi panels",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "siemens",
        "version": "comfort panels"
      },
      {
        "model": "simatic hmi panels",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "siemens",
        "version": "mobile panels"
      },
      {
        "model": "simatic wincc",
        "scope": "lt",
        "trust": 0.8,
        "vendor": "siemens",
        "version": "v11 sp2 update 1"
      },
      {
        "model": "simatic wincc flexible",
        "scope": "lt",
        "trust": 0.8,
        "vendor": "siemens",
        "version": "2008 sp3"
      },
      {
        "model": "simatic wincc flexible rumtime",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic wincc runtime advanced",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "siemens",
        "version": "v11"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.6,
        "vendor": "wincc flexible",
        "version": "2008"
      },
      {
        "model": "simatic wincc flexible runtime",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic wincc runtime advanced",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic wincc flexible",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "2008"
      },
      {
        "model": "simatic hmi panels",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic wincc",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic wincc",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v11"
      },
      {
        "model": "wincc flexible runtime",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.4,
        "vendor": "wincc",
        "version": "v11"
      },
      {
        "model": "simatic hmi smart options",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic hmi",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "wincc flexible",
        "version": "2004"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "wincc flexible",
        "version": "2005"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "wincc flexible",
        "version": "2007"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "wincc",
        "version": "*"
      },
      {
        "model": "comfort panels",
        "scope": null,
        "trust": 0.2,
        "vendor": "simatic hmi panels",
        "version": null
      },
      {
        "model": "mobile panels",
        "scope": null,
        "trust": 0.2,
        "vendor": "simatic hmi panels",
        "version": null
      },
      {
        "model": "mp",
        "scope": null,
        "trust": 0.2,
        "vendor": "simatic hmi panels",
        "version": null
      },
      {
        "model": "op",
        "scope": null,
        "trust": 0.2,
        "vendor": "simatic hmi panels",
        "version": null
      },
      {
        "model": "tp",
        "scope": null,
        "trust": 0.2,
        "vendor": "simatic hmi panels",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "wincc runtime advanced",
        "version": "v11"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "wincc flexible runtime",
        "version": "*"
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "28629d64-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2012-0461"
      },
      {
        "db": "BID",
        "id": "51835"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001313"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201202-086"
      },
      {
        "db": "NVD",
        "id": "CVE-2011-4511"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/a:siemens:simatic_hmi_panels",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/a:siemens:simatic_wincc_%28tia_portal%29",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/a:siemens:wincc_flexible",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/a:siemens:wincc_flexible_runtime",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/a:siemens:wincc_runtime_advanced",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001313"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Billy Rios, Terry McCorkle, Shawn Merdinger, and Luigi Auriemma.",
    "sources": [
      {
        "db": "BID",
        "id": "51835"
      }
    ],
    "trust": 0.3
  },
  "cve": "CVE-2011-4511",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "NONE",
            "baseScore": 4.3,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 8.6,
            "id": "CVE-2011-4511",
            "impactScore": 2.9,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 1.9,
            "vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N",
            "version": "2.0"
          },
          {
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "IVD",
            "availabilityImpact": "NONE",
            "baseScore": 4.3,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 8.6,
            "id": "28629d64-2354-11e6-abef-000c29c66e3d",
            "impactScore": 2.9,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 0.2,
            "vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N",
            "version": "2.9 [IVD]"
          },
          {
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "NONE",
            "baseScore": 4.3,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 8.6,
            "id": "VHN-52456",
            "impactScore": 2.9,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 0.1,
            "vectorString": "AV:N/AC:M/AU:N/C:N/I:P/A:N",
            "version": "2.0"
          }
        ],
        "cvssV3": [],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2011-4511",
            "trust": 1.0,
            "value": "MEDIUM"
          },
          {
            "author": "NVD",
            "id": "CVE-2011-4511",
            "trust": 0.8,
            "value": "Medium"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201202-086",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "IVD",
            "id": "28629d64-2354-11e6-abef-000c29c66e3d",
            "trust": 0.2,
            "value": "MEDIUM"
          },
          {
            "author": "VULHUB",
            "id": "VHN-52456",
            "trust": 0.1,
            "value": "MEDIUM"
          },
          {
            "author": "VULMON",
            "id": "CVE-2011-4511",
            "trust": 0.1,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "28629d64-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "VULHUB",
        "id": "VHN-52456"
      },
      {
        "db": "VULMON",
        "id": "CVE-2011-4511"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001313"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201202-086"
      },
      {
        "db": "NVD",
        "id": "CVE-2011-4511"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Cross-site scripting (XSS) vulnerability in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allows remote attackers to inject arbitrary web script or HTML via unspecified vectors, a different vulnerability than CVE-2011-4510. plural Siemens Product HMI Web The server contains a cross-site scripting vulnerability. This vulnerability is CVE-2011-4510 This is a different vulnerability.By any third party, Web Script or HTML May be inserted. Siemens SIMATIC is an automation software in a single engineering environment. The SIMATIC HMI Smart Options web server has two separate cross-site scripting attacks that allow elevation of privilege, stealing data or corrupting services. SIMATIC HMI is prone to multiple unspecified cross-site scripting vulnerabilities because it fails to properly sanitize user-supplied input. \nAn attacker may leverage these issues to execute arbitrary script code in the browser of an unsuspecting user in the context of the affected site. This can allow the attacker to steal cookie-based authentication credentials and launch other attacks",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2011-4511"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001313"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2012-0461"
      },
      {
        "db": "BID",
        "id": "51835"
      },
      {
        "db": "IVD",
        "id": "28629d64-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "VULHUB",
        "id": "VHN-52456"
      },
      {
        "db": "VULMON",
        "id": "CVE-2011-4511"
      }
    ],
    "trust": 2.79
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2011-4511",
        "trust": 3.7
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-12-030-01",
        "trust": 3.5
      },
      {
        "db": "SIEMENS",
        "id": "SSA-345442",
        "trust": 1.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201202-086",
        "trust": 0.9
      },
      {
        "db": "CNVD",
        "id": "CNVD-2012-0461",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001313",
        "trust": 0.8
      },
      {
        "db": "NSFOCUS",
        "id": "19403",
        "trust": 0.6
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-12-030-01A",
        "trust": 0.4
      },
      {
        "db": "BID",
        "id": "51835",
        "trust": 0.4
      },
      {
        "db": "IVD",
        "id": "28629D64-2354-11E6-ABEF-000C29C66E3D",
        "trust": 0.2
      },
      {
        "db": "VULHUB",
        "id": "VHN-52456",
        "trust": 0.1
      },
      {
        "db": "VULMON",
        "id": "CVE-2011-4511",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "28629d64-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2012-0461"
      },
      {
        "db": "VULHUB",
        "id": "VHN-52456"
      },
      {
        "db": "VULMON",
        "id": "CVE-2011-4511"
      },
      {
        "db": "BID",
        "id": "51835"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001313"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201202-086"
      },
      {
        "db": "NVD",
        "id": "CVE-2011-4511"
      }
    ]
  },
  "id": "VAR-201202-0046",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "IVD",
        "id": "28629d64-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2012-0461"
      },
      {
        "db": "VULHUB",
        "id": "VHN-52456"
      }
    ],
    "trust": 1.5239411500000002
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "28629d64-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2012-0461"
      }
    ]
  },
  "last_update_date": "2025-04-11T22:49:48.610000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "SSA-345442",
        "trust": 0.8,
        "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf"
      },
      {
        "title": "\u30bd\u30ea\u30e5\u30fc\u30b7\u30e7\u30f3\u30d1\u30fc\u30c8\u30ca\u30fc",
        "trust": 0.8,
        "url": "http://www.automation.siemens.com/automation/jp/ja/solutionpartner/pages/default.aspx"
      },
      {
        "title": "Top Page",
        "trust": 0.8,
        "url": "http://www.siemens.com/entry/jp/ja/"
      },
      {
        "title": "Patch for Siemens SIMATIC WinCC HMI Cross-Site Scripting Vulnerability (CNVD-2012-0461)",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/9059"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2012-0461"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001313"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-79",
        "trust": 1.9
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-52456"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001313"
      },
      {
        "db": "NVD",
        "id": "CVE-2011-4511"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 3.5,
        "url": "http://www.us-cert.gov/control_systems/pdf/icsa-12-030-01.pdf"
      },
      {
        "trust": 1.8,
        "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf"
      },
      {
        "trust": 0.8,
        "url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2011-4511"
      },
      {
        "trust": 0.8,
        "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2011-4511"
      },
      {
        "trust": 0.6,
        "url": "http://www.nsfocus.net/vulndb/19403"
      },
      {
        "trust": 0.3,
        "url": "http://www.automation.siemens.com/mcms/automation/en/human-machine-interface/pages/default.aspx"
      },
      {
        "trust": 0.3,
        "url": "http://www.us-cert.gov/control_systems/pdf/icsa-12-030-01a.pdf"
      },
      {
        "trust": 0.1,
        "url": "https://cwe.mitre.org/data/definitions/79.html"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      },
      {
        "trust": 0.1,
        "url": "https://www.securityfocus.com/bid/51835"
      },
      {
        "trust": 0.1,
        "url": "https://ics-cert.us-cert.gov/advisories/icsa-12-030-01a"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2012-0461"
      },
      {
        "db": "VULHUB",
        "id": "VHN-52456"
      },
      {
        "db": "VULMON",
        "id": "CVE-2011-4511"
      },
      {
        "db": "BID",
        "id": "51835"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001313"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201202-086"
      },
      {
        "db": "NVD",
        "id": "CVE-2011-4511"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "IVD",
        "id": "28629d64-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2012-0461"
      },
      {
        "db": "VULHUB",
        "id": "VHN-52456"
      },
      {
        "db": "VULMON",
        "id": "CVE-2011-4511"
      },
      {
        "db": "BID",
        "id": "51835"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001313"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201202-086"
      },
      {
        "db": "NVD",
        "id": "CVE-2011-4511"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2012-02-07T00:00:00",
        "db": "IVD",
        "id": "28629d64-2354-11e6-abef-000c29c66e3d"
      },
      {
        "date": "2012-02-07T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2012-0461"
      },
      {
        "date": "2012-02-03T00:00:00",
        "db": "VULHUB",
        "id": "VHN-52456"
      },
      {
        "date": "2012-02-03T00:00:00",
        "db": "VULMON",
        "id": "CVE-2011-4511"
      },
      {
        "date": "2012-01-30T00:00:00",
        "db": "BID",
        "id": "51835"
      },
      {
        "date": "2012-02-08T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2012-001313"
      },
      {
        "date": "2012-02-07T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201202-086"
      },
      {
        "date": "2012-02-03T20:55:01.407000",
        "db": "NVD",
        "id": "CVE-2011-4511"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2012-02-07T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2012-0461"
      },
      {
        "date": "2012-02-06T00:00:00",
        "db": "VULHUB",
        "id": "VHN-52456"
      },
      {
        "date": "2012-02-06T00:00:00",
        "db": "VULMON",
        "id": "CVE-2011-4511"
      },
      {
        "date": "2012-04-18T21:20:00",
        "db": "BID",
        "id": "51835"
      },
      {
        "date": "2012-02-08T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2012-001313"
      },
      {
        "date": "2012-02-07T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201202-086"
      },
      {
        "date": "2025-04-11T00:51:21.963000",
        "db": "NVD",
        "id": "CVE-2011-4511"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201202-086"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "plural  Siemens Product  HMI Web Server vulnerable to cross-site scripting",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001313"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "XSS",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201202-086"
      }
    ],
    "trust": 0.6
  }
}

VAR-201202-0163

Vulnerability from variot - Updated: 2025-04-11 22:49

Directory traversal vulnerability in HmiLoad in the runtime loader in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime, when Transfer Mode is enabled, allows remote attackers to execute, read, create, modify, or delete arbitrary files via a .. (dot dot) in a string. plural Siemens Product runtime loader HmiLoad Is Transfer A directory traversal vulnerability exists when the mode is enabled.By a third party .. ( Dot dot ) Arbitrary files may be executed, read, created, modified, or deleted via strings containing. Miniweb has a security vulnerability that allows an attacker to submit a specially crafted HTTP POST request to allow the server to access any illegal memory area while checking the extension of the requested file. Siemens SIMATIC WinCC is a multi-user system that provides complete monitoring and data acquisition (SCADA) functionality for the industrial sector, from single-user systems to redundant server and remote web client solutions. HmiLoad provides functions that read data and unicode strings with stack-based buffer overflows, allowing an attacker to exploit a vulnerability to execute arbitrary code. HmiLoad has multiple security vulnerabilities that allow an attacker to stop a service or crash a service in multiple ways. A directory traversal vulnerability exists in the HmiLoad server that allows reading, writing, and deleting arbitrary files outside of the specified directory. Siemens SIMATIC is an automation software in a single engineering environment. A security vulnerability exists in the Siemens SIMATIC WinCC HMI web server. When the transfer mode is enabled, the runtime loader listens on the 2308/TCP or 50523/TCP port, but does not verify the submitted string, allowing the attacker to read and write any file in the file system. Attackers can exploit these issues to execute arbitrary code in the context of the affected application, read/write or delete arbitrary files outside of the server root directory, or cause denial-of-service conditions; other attacks may also be possible. (dots) in strings. ----------------------------------------------------------------------

Secunia is hiring!

Find your next job here:

http://secunia.com/company/jobs/


TITLE: Siemens SIMATIC WinCC Flexible HMI Miniweb Two Vulnerabilities

SECUNIA ADVISORY ID: SA46997

VERIFY ADVISORY: Secunia.com http://secunia.com/advisories/46997/ Customer Area (Credentials Required) https://ca.secunia.com/?page=viewadvisory&vuln_id=46997

RELEASE DATE: 2011-11-30

DISCUSS ADVISORY: http://secunia.com/advisories/46997/#comments

AVAILABLE ON SITE AND IN CUSTOMER AREA: * Last Update * Popularity * Comments * Criticality Level * Impact * Where * Solution Status * Operating System / Software * CVE Reference(s)

http://secunia.com/advisories/46997/

ONLY AVAILABLE IN CUSTOMER AREA: * Authentication Level * Report Reliability * Secunia PoC * Secunia Analysis * Systems Affected * Approve Distribution * Remediation Status * Secunia CVSS Score * CVSS

https://ca.secunia.com/?page=viewadvisory&vuln_id=46997

ONLY AVAILABLE WITH SECUNIA CSI AND SECUNIA PSI: * AUTOMATED SCANNING

http://secunia.com/vulnerability_scanning/personal/ http://secunia.com/vulnerability_scanning/corporate/wsus_sccm_3rd_third_party_patching/

DESCRIPTION: Luigi Auriemma has discovered two vulnerabilities in Siemens SIMATIC WinCC Flexible, which can be exploited by malicious people to disclose potentially sensitive information and cause a DoS (Denial of Service).

1) An input sanitisation error in Miniweb.exe when handling HTTP GET requests can be exploited to download arbitrary files via directory traversal attacks sent in a web request.

2) An input validation error in Miniweb.exe when handling HTTP POST requests can be exploited to crash the process via specially crafted content sent in a web request.

The vulnerabilities are confirmed in version 2008 SP2 Upd13 (K01.03.02.13_01.02.00.01). Other versions may also be affected.

SOLUTION: Restrict access to trusted hosts only.

PROVIDED AND/OR DISCOVERED BY: Luigi Auriemma

ORIGINAL ADVISORY: http://aluigi.altervista.org/adv/winccflex_1-adv.txt

OTHER REFERENCES: Further details available in Customer Area: http://secunia.com/vulnerability_intelligence/

DEEP LINKS: Further details available in Customer Area: http://secunia.com/vulnerability_intelligence/

EXTENDED DESCRIPTION: Further details available in Customer Area: http://secunia.com/vulnerability_intelligence/

EXTENDED SOLUTION: Further details available in Customer Area: http://secunia.com/vulnerability_intelligence/

EXPLOIT: Further details available in Customer Area: http://secunia.com/vulnerability_intelligence/


About: This Advisory was delivered by Secunia as a free service to help private users keeping their systems up to date against the latest vulnerabilities.

Subscribe: http://secunia.com/advisories/secunia_security_advisories/

Definitions: (Criticality, Where etc.) http://secunia.com/advisories/about_secunia_advisories/

Please Note: Secunia recommends that you verify all advisories you receive by clicking the link. Secunia NEVER sends attached files with advisories. Secunia does not advise people to install third party patches, only use those supplied by the vendor.


Unsubscribe: Secunia Security Advisories http://secunia.com/sec_adv_unsubscribe/?email=packet%40packetstormsecurity.org


Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201202-0163",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "simatic wincc flexible runtime",
        "scope": null,
        "trust": 3.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic wincc flexible sp2",
        "scope": "eq",
        "trust": 3.3,
        "vendor": "siemens",
        "version": "2008"
      },
      {
        "model": "simatic hmi panels",
        "scope": "eq",
        "trust": 2.4,
        "vendor": "siemens",
        "version": "mp"
      },
      {
        "model": "simatic hmi panels",
        "scope": "eq",
        "trust": 2.4,
        "vendor": "siemens",
        "version": "op"
      },
      {
        "model": "simatic hmi panels",
        "scope": "eq",
        "trust": 2.4,
        "vendor": "siemens",
        "version": "tp"
      },
      {
        "model": "simatic wincc flexible",
        "scope": "eq",
        "trust": 1.7,
        "vendor": "siemens",
        "version": "2008"
      },
      {
        "model": "simatic wincc flexible",
        "scope": "eq",
        "trust": 1.7,
        "vendor": "siemens",
        "version": "2007"
      },
      {
        "model": "simatic wincc flexible",
        "scope": "eq",
        "trust": 1.7,
        "vendor": "siemens",
        "version": "2005"
      },
      {
        "model": "simatic wincc flexible",
        "scope": "eq",
        "trust": 1.7,
        "vendor": "siemens",
        "version": "2004"
      },
      {
        "model": "wincc flexible",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "2008"
      },
      {
        "model": "simatic hmi panels",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "comfort_panels"
      },
      {
        "model": "wincc runtime advanced",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "v11"
      },
      {
        "model": "wincc",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "v11"
      },
      {
        "model": "simatic hmi panels",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "mobile_panels"
      },
      {
        "model": "wincc flexible",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "2007"
      },
      {
        "model": "simatic wincc",
        "scope": "eq",
        "trust": 1.4,
        "vendor": "siemens",
        "version": "v11"
      },
      {
        "model": "wincc flexible",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2004"
      },
      {
        "model": "wincc flexible runtime",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "wincc flexible",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2005"
      },
      {
        "model": "simatic hmi panels",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "siemens",
        "version": "comfort panels"
      },
      {
        "model": "simatic hmi panels",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "siemens",
        "version": "mobile panels"
      },
      {
        "model": "simatic wincc flexible rumtime",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic wincc runtime advanced",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "siemens",
        "version": "v11"
      },
      {
        "model": "simatic wincc runtime advanced",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic hmi panels",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic wincc",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "wincc flexible runtime",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic wincc flexible runtime",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic wincc flexible sp1",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "2008"
      },
      {
        "model": "simatic wincc flexible sp1",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "2005"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "wincc flexible",
        "version": "2004"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "wincc flexible",
        "version": "2005"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "wincc flexible",
        "version": "2007"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "wincc flexible",
        "version": "2008"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "wincc",
        "version": "v11"
      },
      {
        "model": "comfort panels",
        "scope": null,
        "trust": 0.2,
        "vendor": "simatic hmi panels",
        "version": null
      },
      {
        "model": "mobile panels",
        "scope": null,
        "trust": 0.2,
        "vendor": "simatic hmi panels",
        "version": null
      },
      {
        "model": "mp",
        "scope": null,
        "trust": 0.2,
        "vendor": "simatic hmi panels",
        "version": null
      },
      {
        "model": "op",
        "scope": null,
        "trust": 0.2,
        "vendor": "simatic hmi panels",
        "version": null
      },
      {
        "model": "tp",
        "scope": null,
        "trust": 0.2,
        "vendor": "simatic hmi panels",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "wincc runtime advanced",
        "version": "v11"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "wincc flexible runtime",
        "version": "*"
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "28b71d12-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5108"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5110"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5103"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5107"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5105"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2012-0466"
      },
      {
        "db": "BID",
        "id": "50828"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001318"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201202-091"
      },
      {
        "db": "NVD",
        "id": "CVE-2011-4876"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/a:siemens:simatic_hmi_panels",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/a:siemens:simatic_wincc_%28tia_portal%29",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/a:siemens:wincc_flexible",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/a:siemens:wincc_flexible_runtime",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/a:siemens:wincc_runtime_advanced",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001318"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Luigi Auriemma",
    "sources": [
      {
        "db": "BID",
        "id": "50828"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201111-480"
      }
    ],
    "trust": 0.9
  },
  "cve": "CVE-2011-4876",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "COMPLETE",
            "baseScore": 9.3,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 8.6,
            "id": "CVE-2011-4876",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 1.8,
            "vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "IVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 9.3,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 8.6,
            "id": "28b71d12-2354-11e6-abef-000c29c66e3d",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.2,
            "vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C",
            "version": "2.9 [IVD]"
          },
          {
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "COMPLETE",
            "baseScore": 9.3,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 8.6,
            "id": "VHN-52821",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.1,
            "vectorString": "AV:N/AC:M/AU:N/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2011-4876",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "NVD",
            "id": "CVE-2011-4876",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201202-091",
            "trust": 0.6,
            "value": "CRITICAL"
          },
          {
            "author": "IVD",
            "id": "28b71d12-2354-11e6-abef-000c29c66e3d",
            "trust": 0.2,
            "value": "CRITICAL"
          },
          {
            "author": "VULHUB",
            "id": "VHN-52821",
            "trust": 0.1,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "28b71d12-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "VULHUB",
        "id": "VHN-52821"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001318"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201202-091"
      },
      {
        "db": "NVD",
        "id": "CVE-2011-4876"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Directory traversal vulnerability in HmiLoad in the runtime loader in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime, when Transfer Mode is enabled, allows remote attackers to execute, read, create, modify, or delete arbitrary files via a .. (dot dot) in a string. plural Siemens Product runtime loader HmiLoad Is Transfer A directory traversal vulnerability exists when the mode is enabled.By a third party .. ( Dot dot ) Arbitrary files may be executed, read, created, modified, or deleted via strings containing. Miniweb has a security vulnerability that allows an attacker to submit a specially crafted HTTP POST request to allow the server to access any illegal memory area while checking the extension of the requested file. Siemens SIMATIC WinCC is a multi-user system that provides complete monitoring and data acquisition (SCADA) functionality for the industrial sector, from single-user systems to redundant server and remote web client solutions. HmiLoad provides functions that read data and unicode strings with stack-based buffer overflows, allowing an attacker to exploit a vulnerability to execute arbitrary code. HmiLoad has multiple security vulnerabilities that allow an attacker to stop a service or crash a service in multiple ways. A directory traversal vulnerability exists in the HmiLoad server that allows reading, writing, and deleting arbitrary files outside of the specified directory. Siemens SIMATIC is an automation software in a single engineering environment. A security vulnerability exists in the Siemens SIMATIC WinCC HMI web server. When the transfer mode is enabled, the runtime loader listens on the 2308/TCP or 50523/TCP port, but does not verify the submitted string, allowing the attacker to read and write any file in the file system. \nAttackers can exploit these issues to execute arbitrary code in the context of the affected application, read/write or delete arbitrary files outside of the server root directory, or cause denial-of-service conditions; other attacks may also be possible. (dots) in strings. ----------------------------------------------------------------------\n\nSecunia is hiring!\n\nFind your next job here:\n\nhttp://secunia.com/company/jobs/\n\n----------------------------------------------------------------------\n\nTITLE:\nSiemens SIMATIC WinCC Flexible HMI Miniweb Two Vulnerabilities\n\nSECUNIA ADVISORY ID:\nSA46997\n\nVERIFY ADVISORY:\nSecunia.com\nhttp://secunia.com/advisories/46997/\nCustomer Area (Credentials Required)\nhttps://ca.secunia.com/?page=viewadvisory\u0026vuln_id=46997\n\nRELEASE DATE:\n2011-11-30\n\nDISCUSS ADVISORY:\nhttp://secunia.com/advisories/46997/#comments\n\nAVAILABLE ON SITE AND IN CUSTOMER AREA:\n * Last Update\n * Popularity\n * Comments\n * Criticality Level\n * Impact\n * Where\n * Solution Status\n * Operating System / Software\n * CVE Reference(s)\n\nhttp://secunia.com/advisories/46997/\n\nONLY AVAILABLE IN CUSTOMER AREA:\n * Authentication Level\n * Report Reliability\n * Secunia PoC\n * Secunia Analysis\n * Systems Affected\n * Approve Distribution\n * Remediation Status\n * Secunia CVSS Score\n * CVSS\n\nhttps://ca.secunia.com/?page=viewadvisory\u0026vuln_id=46997\n\nONLY AVAILABLE WITH SECUNIA CSI AND SECUNIA PSI:\n * AUTOMATED SCANNING\n\nhttp://secunia.com/vulnerability_scanning/personal/\nhttp://secunia.com/vulnerability_scanning/corporate/wsus_sccm_3rd_third_party_patching/\n\nDESCRIPTION:\nLuigi Auriemma has discovered two vulnerabilities in Siemens SIMATIC\nWinCC Flexible, which can be exploited by malicious people to\ndisclose potentially sensitive information and cause a DoS (Denial of\nService). \n\n1) An input sanitisation error in Miniweb.exe when handling HTTP GET\nrequests can be exploited to download arbitrary files via directory\ntraversal attacks sent in a web request. \n\n2) An input validation error in Miniweb.exe when handling HTTP POST\nrequests can be exploited to crash the process via specially crafted\ncontent sent in a web request. \n\nThe vulnerabilities are confirmed in version 2008 SP2 Upd13\n(K01.03.02.13_01.02.00.01). Other versions may also be affected. \n\nSOLUTION:\nRestrict access to trusted hosts only. \n\nPROVIDED AND/OR DISCOVERED BY:\nLuigi Auriemma\n\nORIGINAL ADVISORY:\nhttp://aluigi.altervista.org/adv/winccflex_1-adv.txt\n\nOTHER REFERENCES:\nFurther details available in Customer Area:\nhttp://secunia.com/vulnerability_intelligence/\n\nDEEP LINKS:\nFurther details available in Customer Area:\nhttp://secunia.com/vulnerability_intelligence/\n\nEXTENDED DESCRIPTION:\nFurther details available in Customer Area:\nhttp://secunia.com/vulnerability_intelligence/\n\nEXTENDED SOLUTION:\nFurther details available in Customer Area:\nhttp://secunia.com/vulnerability_intelligence/\n\nEXPLOIT:\nFurther details available in Customer Area:\nhttp://secunia.com/vulnerability_intelligence/\n\n----------------------------------------------------------------------\n\nAbout:\nThis Advisory was delivered by Secunia as a free service to help\nprivate users keeping their systems up to date against the latest\nvulnerabilities. \n\nSubscribe:\nhttp://secunia.com/advisories/secunia_security_advisories/\n\nDefinitions: (Criticality, Where etc.)\nhttp://secunia.com/advisories/about_secunia_advisories/\n\n\nPlease Note:\nSecunia recommends that you verify all advisories you receive by\nclicking the link. \nSecunia NEVER sends attached files with advisories. \nSecunia does not advise people to install third party patches, only\nuse those supplied by the vendor. \n\n----------------------------------------------------------------------\n\nUnsubscribe: Secunia Security Advisories\nhttp://secunia.com/sec_adv_unsubscribe/?email=packet%40packetstormsecurity.org\n\n----------------------------------------------------------------------\n\n\n",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2011-4876"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001318"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5108"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5110"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5103"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5107"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5105"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2012-0466"
      },
      {
        "db": "BID",
        "id": "50828"
      },
      {
        "db": "IVD",
        "id": "28b71d12-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "VULHUB",
        "id": "VHN-52821"
      },
      {
        "db": "PACKETSTORM",
        "id": "107419"
      }
    ],
    "trust": 5.49
  },
  "exploit_availability": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/exploit_availability#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "reference": "https://www.scap.org.cn/vuln/vhn-52821",
        "trust": 0.1,
        "type": "unknown"
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-52821"
      }
    ]
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "BID",
        "id": "50828",
        "trust": 3.9
      },
      {
        "db": "NVD",
        "id": "CVE-2011-4876",
        "trust": 3.6
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-12-030-01",
        "trust": 3.4
      },
      {
        "db": "SIEMENS",
        "id": "SSA-345442",
        "trust": 1.7
      },
      {
        "db": "SECUNIA",
        "id": "46997",
        "trust": 1.2
      },
      {
        "db": "ICS CERT ALERT",
        "id": "ICS-ALERT-11-332-02A",
        "trust": 1.1
      },
      {
        "db": "ICS CERT ALERT",
        "id": "ICS-ALERT-11-332-02",
        "trust": 1.1
      },
      {
        "db": "OSVDB",
        "id": "77381",
        "trust": 1.1
      },
      {
        "db": "EXPLOIT-DB",
        "id": "18166",
        "trust": 1.1
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201202-091",
        "trust": 0.9
      },
      {
        "db": "CNVD",
        "id": "CNVD-2012-0466",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001318",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5108",
        "trust": 0.6
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5110",
        "trust": 0.6
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5103",
        "trust": 0.6
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5107",
        "trust": 0.6
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5105",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201111-480",
        "trust": 0.6
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-12-030-01A",
        "trust": 0.3
      },
      {
        "db": "IVD",
        "id": "28B71D12-2354-11E6-ABEF-000C29C66E3D",
        "trust": 0.2
      },
      {
        "db": "VULHUB",
        "id": "VHN-52821",
        "trust": 0.1
      },
      {
        "db": "PACKETSTORM",
        "id": "107419",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "28b71d12-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5108"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5110"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5103"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5107"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5105"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2012-0466"
      },
      {
        "db": "VULHUB",
        "id": "VHN-52821"
      },
      {
        "db": "BID",
        "id": "50828"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001318"
      },
      {
        "db": "PACKETSTORM",
        "id": "107419"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201111-480"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201202-091"
      },
      {
        "db": "NVD",
        "id": "CVE-2011-4876"
      }
    ]
  },
  "id": "VAR-201202-0163",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "IVD",
        "id": "28b71d12-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5108"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5110"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5103"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5107"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5105"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2012-0466"
      },
      {
        "db": "VULHUB",
        "id": "VHN-52821"
      }
    ],
    "trust": 4.568457485714285
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 3.8
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "28b71d12-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5108"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5110"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5103"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5107"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5105"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2012-0466"
      }
    ]
  },
  "last_update_date": "2025-04-11T22:49:48.540000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "SSA-345442",
        "trust": 0.8,
        "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf"
      },
      {
        "title": "\u30bd\u30ea\u30e5\u30fc\u30b7\u30e7\u30f3\u30d1\u30fc\u30c8\u30ca\u30fc",
        "trust": 0.8,
        "url": "http://www.automation.siemens.com/automation/jp/ja/solutionpartner/pages/default.aspx"
      },
      {
        "title": "Top Page",
        "trust": 0.8,
        "url": "http://www.siemens.com/entry/jp/ja/"
      },
      {
        "title": "Patch for Siemens SIMATIC WinCC Flexible Runtime \u0027HmiLoad.exe\u0027 file download vulnerability",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/72694"
      },
      {
        "title": "Siemens SIMATIC WinCC Flexible Runtime \u0027HmiLoad.exe\u0027 memory access vulnerability patch",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/72697"
      },
      {
        "title": "Siemens SIMATIC WinCC Flexible Runtime \u0027HmiLoad.exe\u0027 Buffer Overflow Vulnerability Patch",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/72705"
      },
      {
        "title": "Siemens SIMATIC WinCC Flexible Runtime \u0027HmiLoad.exe\u0027 service crash vulnerability patch",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/72689"
      },
      {
        "title": "Patch for Siemens SIMATIC WinCC HMI Directory Traversal Vulnerability (CNVD-2012-0466)",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/9072"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2011-5108"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5110"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5103"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5107"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2012-0466"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001318"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-22",
        "trust": 1.9
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-52821"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001318"
      },
      {
        "db": "NVD",
        "id": "CVE-2011-4876"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 4.0,
        "url": "http://aluigi.altervista.org/adv/winccflex_1-adv.txt"
      },
      {
        "trust": 3.4,
        "url": "http://www.us-cert.gov/control_systems/pdf/icsa-12-030-01.pdf"
      },
      {
        "trust": 1.7,
        "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf"
      },
      {
        "trust": 1.1,
        "url": "http://www.exploit-db.com/exploits/18166"
      },
      {
        "trust": 1.1,
        "url": "http://aluigi.org/adv/winccflex_1-adv.txt"
      },
      {
        "trust": 1.1,
        "url": "http://www.us-cert.gov/control_systems/pdf/ics-alert-11-332-02.pdf"
      },
      {
        "trust": 1.1,
        "url": "http://www.us-cert.gov/control_systems/pdf/ics-alert-11-332-02a.pdf"
      },
      {
        "trust": 1.1,
        "url": "http://www.osvdb.org/77381"
      },
      {
        "trust": 1.1,
        "url": "http://secunia.com/advisories/46997"
      },
      {
        "trust": 1.1,
        "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/71450"
      },
      {
        "trust": 0.8,
        "url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2011-4876"
      },
      {
        "trust": 0.8,
        "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2011-4876"
      },
      {
        "trust": 0.6,
        "url": "http://www.securityfocus.com/bid/50828"
      },
      {
        "trust": 0.3,
        "url": "http://www.automation.siemens.com/mcms/human-machine-interface/en/visualization-software/wincc-flexible/wincc-flexible-runtime/pages/default.aspx"
      },
      {
        "trust": 0.3,
        "url": "http://www.us-cert.gov/control_systems/pdf/icsa-12-030-01a.pdf"
      },
      {
        "trust": 0.1,
        "url": "http://secunia.com/company/jobs/"
      },
      {
        "trust": 0.1,
        "url": "http://secunia.com/vulnerability_intelligence/"
      },
      {
        "trust": 0.1,
        "url": "http://secunia.com/vulnerability_scanning/corporate/wsus_sccm_3rd_third_party_patching/"
      },
      {
        "trust": 0.1,
        "url": "http://secunia.com/advisories/secunia_security_advisories/"
      },
      {
        "trust": 0.1,
        "url": "http://secunia.com/vulnerability_scanning/personal/"
      },
      {
        "trust": 0.1,
        "url": "http://secunia.com/advisories/46997/"
      },
      {
        "trust": 0.1,
        "url": "http://secunia.com/sec_adv_unsubscribe/?email=packet%40packetstormsecurity.org"
      },
      {
        "trust": 0.1,
        "url": "https://ca.secunia.com/?page=viewadvisory\u0026vuln_id=46997"
      },
      {
        "trust": 0.1,
        "url": "http://secunia.com/advisories/46997/#comments"
      },
      {
        "trust": 0.1,
        "url": "http://secunia.com/advisories/about_secunia_advisories/"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2011-5108"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5110"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5103"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5107"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5105"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2012-0466"
      },
      {
        "db": "VULHUB",
        "id": "VHN-52821"
      },
      {
        "db": "BID",
        "id": "50828"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001318"
      },
      {
        "db": "PACKETSTORM",
        "id": "107419"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201111-480"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201202-091"
      },
      {
        "db": "NVD",
        "id": "CVE-2011-4876"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "IVD",
        "id": "28b71d12-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5108"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5110"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5103"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5107"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5105"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2012-0466"
      },
      {
        "db": "VULHUB",
        "id": "VHN-52821"
      },
      {
        "db": "BID",
        "id": "50828"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001318"
      },
      {
        "db": "PACKETSTORM",
        "id": "107419"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201111-480"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201202-091"
      },
      {
        "db": "NVD",
        "id": "CVE-2011-4876"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2012-02-07T00:00:00",
        "db": "IVD",
        "id": "28b71d12-2354-11e6-abef-000c29c66e3d"
      },
      {
        "date": "2011-12-05T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2011-5108"
      },
      {
        "date": "2011-12-05T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2011-5110"
      },
      {
        "date": "2011-12-05T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2011-5103"
      },
      {
        "date": "2011-12-05T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2011-5107"
      },
      {
        "date": "2011-12-05T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2011-5105"
      },
      {
        "date": "2012-02-07T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2012-0466"
      },
      {
        "date": "2012-02-03T00:00:00",
        "db": "VULHUB",
        "id": "VHN-52821"
      },
      {
        "date": "2011-11-28T00:00:00",
        "db": "BID",
        "id": "50828"
      },
      {
        "date": "2012-02-08T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2012-001318"
      },
      {
        "date": "2011-11-30T03:40:12",
        "db": "PACKETSTORM",
        "id": "107419"
      },
      {
        "date": "1900-01-01T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201111-480"
      },
      {
        "date": "2012-02-07T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201202-091"
      },
      {
        "date": "2012-02-03T20:55:01.937000",
        "db": "NVD",
        "id": "CVE-2011-4876"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2016-03-15T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2011-5108"
      },
      {
        "date": "2016-03-15T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2011-5110"
      },
      {
        "date": "2016-03-15T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2011-5103"
      },
      {
        "date": "2016-03-15T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2011-5107"
      },
      {
        "date": "2011-12-05T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2011-5105"
      },
      {
        "date": "2012-02-07T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2012-0466"
      },
      {
        "date": "2017-08-29T00:00:00",
        "db": "VULHUB",
        "id": "VHN-52821"
      },
      {
        "date": "2012-04-18T21:20:00",
        "db": "BID",
        "id": "50828"
      },
      {
        "date": "2012-02-08T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2012-001318"
      },
      {
        "date": "2011-11-30T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201111-480"
      },
      {
        "date": "2012-02-07T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201202-091"
      },
      {
        "date": "2025-04-11T00:51:21.963000",
        "db": "NVD",
        "id": "CVE-2011-4876"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201111-480"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201202-091"
      }
    ],
    "trust": 1.2
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "plural  Siemens Product  HmiLoad Vulnerable to directory traversal",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001318"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Path traversal",
    "sources": [
      {
        "db": "IVD",
        "id": "28b71d12-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201202-091"
      }
    ],
    "trust": 0.8
  }
}

VAR-201202-0162

Vulnerability from variot - Updated: 2025-04-11 22:49

Stack-based buffer overflow in HmiLoad in the runtime loader in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime, when Transfer Mode is enabled, allows remote attackers to execute arbitrary code via vectors related to Unicode strings. Miniweb has a security vulnerability that allows an attacker to submit a specially crafted HTTP POST request to allow the server to access any illegal memory area while checking the extension of the requested file. Siemens SIMATIC WinCC is a multi-user system that provides complete monitoring and data acquisition (SCADA) functionality for the industrial sector, from single-user systems to redundant server and remote web client solutions. HmiLoad has multiple security vulnerabilities that allow an attacker to stop a service or crash a service in multiple ways. Siemens SIMATIC is an automation software in a single engineering environment. A security vulnerability exists in the Siemens SIMATIC WinCC HMI web server. When the transfer mode is enabled, the runtime loader listens on the 2308/TCP or 50523/TCP port. Without the correct data segment length and Unicode string, a stack overflow can be triggered, causing arbitrary code execution. A directory traversal vulnerability exists in the HmiLoad server that allows reading, writing, and deleting arbitrary files outside of the specified directory. Attackers can exploit these issues to execute arbitrary code in the context of the affected application, read/write or delete arbitrary files outside of the server root directory, or cause denial-of-service conditions; other attacks may also be possible

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201202-0162",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "simatic wincc flexible runtime",
        "scope": null,
        "trust": 3.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic wincc flexible sp2",
        "scope": "eq",
        "trust": 3.3,
        "vendor": "siemens",
        "version": "2008"
      },
      {
        "model": "simatic hmi panels",
        "scope": "eq",
        "trust": 2.4,
        "vendor": "siemens",
        "version": "mp"
      },
      {
        "model": "simatic hmi panels",
        "scope": "eq",
        "trust": 2.4,
        "vendor": "siemens",
        "version": "op"
      },
      {
        "model": "simatic hmi panels",
        "scope": "eq",
        "trust": 2.4,
        "vendor": "siemens",
        "version": "tp"
      },
      {
        "model": "simatic wincc flexible",
        "scope": "eq",
        "trust": 1.7,
        "vendor": "siemens",
        "version": "2008"
      },
      {
        "model": "simatic wincc flexible",
        "scope": "eq",
        "trust": 1.7,
        "vendor": "siemens",
        "version": "2007"
      },
      {
        "model": "simatic wincc flexible",
        "scope": "eq",
        "trust": 1.7,
        "vendor": "siemens",
        "version": "2005"
      },
      {
        "model": "simatic wincc flexible",
        "scope": "eq",
        "trust": 1.7,
        "vendor": "siemens",
        "version": "2004"
      },
      {
        "model": "wincc flexible",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "2008"
      },
      {
        "model": "simatic hmi panels",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "comfort_panels"
      },
      {
        "model": "wincc runtime advanced",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "v11"
      },
      {
        "model": "wincc",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "v11"
      },
      {
        "model": "simatic hmi panels",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "mobile_panels"
      },
      {
        "model": "wincc flexible",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "2007"
      },
      {
        "model": "simatic wincc",
        "scope": "eq",
        "trust": 1.4,
        "vendor": "siemens",
        "version": "v11"
      },
      {
        "model": "simatic wincc flexible runtime",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic wincc flexible sp2",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2008*"
      },
      {
        "model": "wincc flexible",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2004"
      },
      {
        "model": "wincc flexible runtime",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "wincc flexible",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2005"
      },
      {
        "model": "simatic hmi panels",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "siemens",
        "version": "comfort panels"
      },
      {
        "model": "simatic hmi panels",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "siemens",
        "version": "mobile panels"
      },
      {
        "model": "simatic wincc flexible rumtime",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic wincc runtime advanced",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "siemens",
        "version": "v11"
      },
      {
        "model": "simatic wincc runtime advanced",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic hmi panels",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic wincc",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "wincc flexible runtime",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic wincc flexible runtime",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic wincc flexible sp1",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "2008"
      },
      {
        "model": "simatic wincc flexible sp1",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "2005"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "wincc flexible",
        "version": "2004"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "wincc flexible",
        "version": "2005"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "wincc flexible",
        "version": "2007"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "wincc flexible",
        "version": "2008"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "wincc",
        "version": "v11"
      },
      {
        "model": "comfort panels",
        "scope": null,
        "trust": 0.2,
        "vendor": "simatic hmi panels",
        "version": null
      },
      {
        "model": "mobile panels",
        "scope": null,
        "trust": 0.2,
        "vendor": "simatic hmi panels",
        "version": null
      },
      {
        "model": "mp",
        "scope": null,
        "trust": 0.2,
        "vendor": "simatic hmi panels",
        "version": null
      },
      {
        "model": "op",
        "scope": null,
        "trust": 0.2,
        "vendor": "simatic hmi panels",
        "version": null
      },
      {
        "model": "tp",
        "scope": null,
        "trust": 0.2,
        "vendor": "simatic hmi panels",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "wincc runtime advanced",
        "version": "v11"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "wincc flexible runtime",
        "version": "*"
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "61050c40-1f7d-11e6-abef-000c29c66e3d"
      },
      {
        "db": "IVD",
        "id": "5e37bfa8-1f7d-11e6-abef-000c29c66e3d"
      },
      {
        "db": "IVD",
        "id": "9fe8f34a-1f7d-11e6-abef-000c29c66e3d"
      },
      {
        "db": "IVD",
        "id": "28c3f672-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "IVD",
        "id": "9c31ed38-1f7d-11e6-abef-000c29c66e3d"
      },
      {
        "db": "IVD",
        "id": "9ef7b7be-1f7d-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5108"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5110"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5103"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5107"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2012-0465"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5105"
      },
      {
        "db": "BID",
        "id": "50828"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001317"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201202-090"
      },
      {
        "db": "NVD",
        "id": "CVE-2011-4875"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/a:siemens:simatic_hmi_panels",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/a:siemens:simatic_wincc_%28tia_portal%29",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/a:siemens:wincc_flexible",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/a:siemens:wincc_flexible_runtime",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/a:siemens:wincc_runtime_advanced",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001317"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Luigi Auriemma",
    "sources": [
      {
        "db": "BID",
        "id": "50828"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201111-480"
      }
    ],
    "trust": 0.9
  },
  "cve": "CVE-2011-4875",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "COMPLETE",
            "baseScore": 9.3,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 8.6,
            "id": "CVE-2011-4875",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 1.8,
            "vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "IVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 9.3,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 8.6,
            "id": "61050c40-1f7d-11e6-abef-000c29c66e3d",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.2,
            "vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C",
            "version": "2.9 [IVD]"
          },
          {
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "IVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 9.3,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 8.6,
            "id": "5e37bfa8-1f7d-11e6-abef-000c29c66e3d",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.2,
            "vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C",
            "version": "2.9 [IVD]"
          },
          {
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "IVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 9.3,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 8.6,
            "id": "9fe8f34a-1f7d-11e6-abef-000c29c66e3d",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.2,
            "vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C",
            "version": "2.9 [IVD]"
          },
          {
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "IVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 9.3,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 8.6,
            "id": "28c3f672-2354-11e6-abef-000c29c66e3d",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.2,
            "vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C",
            "version": "2.9 [IVD]"
          },
          {
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "IVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 9.3,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 8.6,
            "id": "9c31ed38-1f7d-11e6-abef-000c29c66e3d",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.2,
            "vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C",
            "version": "2.9 [IVD]"
          },
          {
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "IVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 9.3,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 8.6,
            "id": "9ef7b7be-1f7d-11e6-abef-000c29c66e3d",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.2,
            "vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C",
            "version": "2.9 [IVD]"
          },
          {
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "COMPLETE",
            "baseScore": 9.3,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 8.6,
            "id": "VHN-52820",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.1,
            "vectorString": "AV:N/AC:M/AU:N/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2011-4875",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "NVD",
            "id": "CVE-2011-4875",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201202-090",
            "trust": 0.6,
            "value": "CRITICAL"
          },
          {
            "author": "IVD",
            "id": "61050c40-1f7d-11e6-abef-000c29c66e3d",
            "trust": 0.2,
            "value": "CRITICAL"
          },
          {
            "author": "IVD",
            "id": "5e37bfa8-1f7d-11e6-abef-000c29c66e3d",
            "trust": 0.2,
            "value": "CRITICAL"
          },
          {
            "author": "IVD",
            "id": "9fe8f34a-1f7d-11e6-abef-000c29c66e3d",
            "trust": 0.2,
            "value": "CRITICAL"
          },
          {
            "author": "IVD",
            "id": "28c3f672-2354-11e6-abef-000c29c66e3d",
            "trust": 0.2,
            "value": "CRITICAL"
          },
          {
            "author": "IVD",
            "id": "9c31ed38-1f7d-11e6-abef-000c29c66e3d",
            "trust": 0.2,
            "value": "CRITICAL"
          },
          {
            "author": "IVD",
            "id": "9ef7b7be-1f7d-11e6-abef-000c29c66e3d",
            "trust": 0.2,
            "value": "CRITICAL"
          },
          {
            "author": "VULHUB",
            "id": "VHN-52820",
            "trust": 0.1,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "61050c40-1f7d-11e6-abef-000c29c66e3d"
      },
      {
        "db": "IVD",
        "id": "5e37bfa8-1f7d-11e6-abef-000c29c66e3d"
      },
      {
        "db": "IVD",
        "id": "9fe8f34a-1f7d-11e6-abef-000c29c66e3d"
      },
      {
        "db": "IVD",
        "id": "28c3f672-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "IVD",
        "id": "9c31ed38-1f7d-11e6-abef-000c29c66e3d"
      },
      {
        "db": "IVD",
        "id": "9ef7b7be-1f7d-11e6-abef-000c29c66e3d"
      },
      {
        "db": "VULHUB",
        "id": "VHN-52820"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001317"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201202-090"
      },
      {
        "db": "NVD",
        "id": "CVE-2011-4875"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Stack-based buffer overflow in HmiLoad in the runtime loader in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime, when Transfer Mode is enabled, allows remote attackers to execute arbitrary code via vectors related to Unicode strings. Miniweb has a security vulnerability that allows an attacker to submit a specially crafted HTTP POST request to allow the server to access any illegal memory area while checking the extension of the requested file. Siemens SIMATIC WinCC is a multi-user system that provides complete monitoring and data acquisition (SCADA) functionality for the industrial sector, from single-user systems to redundant server and remote web client solutions. HmiLoad has multiple security vulnerabilities that allow an attacker to stop a service or crash a service in multiple ways. Siemens SIMATIC is an automation software in a single engineering environment. A security vulnerability exists in the Siemens SIMATIC WinCC HMI web server. When the transfer mode is enabled, the runtime loader listens on the 2308/TCP or 50523/TCP port. Without the correct data segment length and Unicode string, a stack overflow can be triggered, causing arbitrary code execution. A directory traversal vulnerability exists in the HmiLoad server that allows reading, writing, and deleting arbitrary files outside of the specified directory. \nAttackers can exploit these issues to execute arbitrary code in the context of the affected application, read/write or delete arbitrary files outside of the server root directory, or cause denial-of-service conditions; other attacks may also be possible",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2011-4875"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001317"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5108"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5110"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5103"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5107"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2012-0465"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5105"
      },
      {
        "db": "BID",
        "id": "50828"
      },
      {
        "db": "IVD",
        "id": "61050c40-1f7d-11e6-abef-000c29c66e3d"
      },
      {
        "db": "IVD",
        "id": "5e37bfa8-1f7d-11e6-abef-000c29c66e3d"
      },
      {
        "db": "IVD",
        "id": "9fe8f34a-1f7d-11e6-abef-000c29c66e3d"
      },
      {
        "db": "IVD",
        "id": "28c3f672-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "IVD",
        "id": "9c31ed38-1f7d-11e6-abef-000c29c66e3d"
      },
      {
        "db": "IVD",
        "id": "9ef7b7be-1f7d-11e6-abef-000c29c66e3d"
      },
      {
        "db": "VULHUB",
        "id": "VHN-52820"
      }
    ],
    "trust": 6.3
  },
  "exploit_availability": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/exploit_availability#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "reference": "https://www.scap.org.cn/vuln/vhn-52820",
        "trust": 0.1,
        "type": "unknown"
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-52820"
      }
    ]
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2011-4875",
        "trust": 4.6
      },
      {
        "db": "BID",
        "id": "50828",
        "trust": 3.9
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-12-030-01",
        "trust": 3.4
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201202-090",
        "trust": 1.9
      },
      {
        "db": "SIEMENS",
        "id": "SSA-345442",
        "trust": 1.7
      },
      {
        "db": "ICS CERT ALERT",
        "id": "ICS-ALERT-11-332-02A",
        "trust": 1.1
      },
      {
        "db": "ICS CERT ALERT",
        "id": "ICS-ALERT-11-332-02",
        "trust": 1.1
      },
      {
        "db": "EXPLOIT-DB",
        "id": "18166",
        "trust": 1.1
      },
      {
        "db": "OSVDB",
        "id": "77380",
        "trust": 1.1
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5103",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5105",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5107",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2012-0465",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5110",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5108",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001317",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201111-480",
        "trust": 0.6
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-12-030-01A",
        "trust": 0.3
      },
      {
        "db": "IVD",
        "id": "61050C40-1F7D-11E6-ABEF-000C29C66E3D",
        "trust": 0.2
      },
      {
        "db": "IVD",
        "id": "5E37BFA8-1F7D-11E6-ABEF-000C29C66E3D",
        "trust": 0.2
      },
      {
        "db": "IVD",
        "id": "9FE8F34A-1F7D-11E6-ABEF-000C29C66E3D",
        "trust": 0.2
      },
      {
        "db": "IVD",
        "id": "28C3F672-2354-11E6-ABEF-000C29C66E3D",
        "trust": 0.2
      },
      {
        "db": "IVD",
        "id": "9C31ED38-1F7D-11E6-ABEF-000C29C66E3D",
        "trust": 0.2
      },
      {
        "db": "IVD",
        "id": "9EF7B7BE-1F7D-11E6-ABEF-000C29C66E3D",
        "trust": 0.2
      },
      {
        "db": "SEEBUG",
        "id": "SSVID-72366",
        "trust": 0.1
      },
      {
        "db": "VULHUB",
        "id": "VHN-52820",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "61050c40-1f7d-11e6-abef-000c29c66e3d"
      },
      {
        "db": "IVD",
        "id": "5e37bfa8-1f7d-11e6-abef-000c29c66e3d"
      },
      {
        "db": "IVD",
        "id": "9fe8f34a-1f7d-11e6-abef-000c29c66e3d"
      },
      {
        "db": "IVD",
        "id": "28c3f672-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "IVD",
        "id": "9c31ed38-1f7d-11e6-abef-000c29c66e3d"
      },
      {
        "db": "IVD",
        "id": "9ef7b7be-1f7d-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5108"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5110"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5103"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5107"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2012-0465"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5105"
      },
      {
        "db": "VULHUB",
        "id": "VHN-52820"
      },
      {
        "db": "BID",
        "id": "50828"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001317"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201111-480"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201202-090"
      },
      {
        "db": "NVD",
        "id": "CVE-2011-4875"
      }
    ]
  },
  "id": "VAR-201202-0162",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "IVD",
        "id": "61050c40-1f7d-11e6-abef-000c29c66e3d"
      },
      {
        "db": "IVD",
        "id": "5e37bfa8-1f7d-11e6-abef-000c29c66e3d"
      },
      {
        "db": "IVD",
        "id": "9fe8f34a-1f7d-11e6-abef-000c29c66e3d"
      },
      {
        "db": "IVD",
        "id": "28c3f672-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "IVD",
        "id": "9c31ed38-1f7d-11e6-abef-000c29c66e3d"
      },
      {
        "db": "IVD",
        "id": "9ef7b7be-1f7d-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5108"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5110"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5103"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5107"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2012-0465"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5105"
      },
      {
        "db": "VULHUB",
        "id": "VHN-52820"
      }
    ],
    "trust": 5.568457485714286
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 4.8
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "61050c40-1f7d-11e6-abef-000c29c66e3d"
      },
      {
        "db": "IVD",
        "id": "5e37bfa8-1f7d-11e6-abef-000c29c66e3d"
      },
      {
        "db": "IVD",
        "id": "9fe8f34a-1f7d-11e6-abef-000c29c66e3d"
      },
      {
        "db": "IVD",
        "id": "28c3f672-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "IVD",
        "id": "9c31ed38-1f7d-11e6-abef-000c29c66e3d"
      },
      {
        "db": "IVD",
        "id": "9ef7b7be-1f7d-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5108"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5110"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5103"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5107"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2012-0465"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5105"
      }
    ]
  },
  "last_update_date": "2025-04-11T22:49:48.450000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "SSA-345442",
        "trust": 0.8,
        "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf"
      },
      {
        "title": "\u30bd\u30ea\u30e5\u30fc\u30b7\u30e7\u30f3\u30d1\u30fc\u30c8\u30ca\u30fc",
        "trust": 0.8,
        "url": "http://www.automation.siemens.com/automation/jp/ja/solutionpartner/pages/default.aspx"
      },
      {
        "title": "Top Page",
        "trust": 0.8,
        "url": "http://www.siemens.com/entry/jp/ja/"
      },
      {
        "title": "Patch for Siemens SIMATIC WinCC Flexible Runtime \u0027HmiLoad.exe\u0027 file download vulnerability",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/72694"
      },
      {
        "title": "Siemens SIMATIC WinCC Flexible Runtime \u0027HmiLoad.exe\u0027 memory access vulnerability patch",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/72697"
      },
      {
        "title": "Siemens SIMATIC WinCC Flexible Runtime \u0027HmiLoad.exe\u0027 Buffer Overflow Vulnerability Patch",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/72705"
      },
      {
        "title": "Siemens SIMATIC WinCC Flexible Runtime \u0027HmiLoad.exe\u0027 service crash vulnerability patch",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/72689"
      },
      {
        "title": "Patch for Siemens SIMATIC WinCC HMI String Stack Overflow Vulnerability (CNVD-2012-0465)",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/9071"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2011-5108"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5110"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5103"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5107"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2012-0465"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001317"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-119",
        "trust": 1.9
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-52820"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001317"
      },
      {
        "db": "NVD",
        "id": "CVE-2011-4875"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 3.9,
        "url": "http://aluigi.altervista.org/adv/winccflex_1-adv.txt"
      },
      {
        "trust": 3.4,
        "url": "http://www.us-cert.gov/control_systems/pdf/icsa-12-030-01.pdf"
      },
      {
        "trust": 1.7,
        "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf"
      },
      {
        "trust": 1.1,
        "url": "http://www.exploit-db.com/exploits/18166"
      },
      {
        "trust": 1.1,
        "url": "http://aluigi.org/adv/winccflex_1-adv.txt"
      },
      {
        "trust": 1.1,
        "url": "http://www.us-cert.gov/control_systems/pdf/ics-alert-11-332-02.pdf"
      },
      {
        "trust": 1.1,
        "url": "http://www.us-cert.gov/control_systems/pdf/ics-alert-11-332-02a.pdf"
      },
      {
        "trust": 1.1,
        "url": "http://www.osvdb.org/77380"
      },
      {
        "trust": 1.1,
        "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/71449"
      },
      {
        "trust": 0.8,
        "url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2011-4875"
      },
      {
        "trust": 0.8,
        "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2011-4875"
      },
      {
        "trust": 0.6,
        "url": "http://www.securityfocus.com/bid/50828"
      },
      {
        "trust": 0.3,
        "url": "http://www.automation.siemens.com/mcms/human-machine-interface/en/visualization-software/wincc-flexible/wincc-flexible-runtime/pages/default.aspx"
      },
      {
        "trust": 0.3,
        "url": "http://www.us-cert.gov/control_systems/pdf/icsa-12-030-01a.pdf"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2011-5108"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5110"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5103"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5107"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2012-0465"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5105"
      },
      {
        "db": "VULHUB",
        "id": "VHN-52820"
      },
      {
        "db": "BID",
        "id": "50828"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001317"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201111-480"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201202-090"
      },
      {
        "db": "NVD",
        "id": "CVE-2011-4875"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "IVD",
        "id": "61050c40-1f7d-11e6-abef-000c29c66e3d"
      },
      {
        "db": "IVD",
        "id": "5e37bfa8-1f7d-11e6-abef-000c29c66e3d"
      },
      {
        "db": "IVD",
        "id": "9fe8f34a-1f7d-11e6-abef-000c29c66e3d"
      },
      {
        "db": "IVD",
        "id": "28c3f672-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "IVD",
        "id": "9c31ed38-1f7d-11e6-abef-000c29c66e3d"
      },
      {
        "db": "IVD",
        "id": "9ef7b7be-1f7d-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5108"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5110"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5103"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5107"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2012-0465"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5105"
      },
      {
        "db": "VULHUB",
        "id": "VHN-52820"
      },
      {
        "db": "BID",
        "id": "50828"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001317"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201111-480"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201202-090"
      },
      {
        "db": "NVD",
        "id": "CVE-2011-4875"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2011-12-05T00:00:00",
        "db": "IVD",
        "id": "61050c40-1f7d-11e6-abef-000c29c66e3d"
      },
      {
        "date": "2011-12-05T00:00:00",
        "db": "IVD",
        "id": "5e37bfa8-1f7d-11e6-abef-000c29c66e3d"
      },
      {
        "date": "2011-12-05T00:00:00",
        "db": "IVD",
        "id": "9fe8f34a-1f7d-11e6-abef-000c29c66e3d"
      },
      {
        "date": "2012-02-07T00:00:00",
        "db": "IVD",
        "id": "28c3f672-2354-11e6-abef-000c29c66e3d"
      },
      {
        "date": "2011-12-05T00:00:00",
        "db": "IVD",
        "id": "9c31ed38-1f7d-11e6-abef-000c29c66e3d"
      },
      {
        "date": "2011-12-05T00:00:00",
        "db": "IVD",
        "id": "9ef7b7be-1f7d-11e6-abef-000c29c66e3d"
      },
      {
        "date": "2011-12-05T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2011-5108"
      },
      {
        "date": "2011-12-05T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2011-5110"
      },
      {
        "date": "2011-12-05T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2011-5103"
      },
      {
        "date": "2011-12-05T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2011-5107"
      },
      {
        "date": "2012-02-07T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2012-0465"
      },
      {
        "date": "2011-12-05T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2011-5105"
      },
      {
        "date": "2012-02-03T00:00:00",
        "db": "VULHUB",
        "id": "VHN-52820"
      },
      {
        "date": "2011-11-28T00:00:00",
        "db": "BID",
        "id": "50828"
      },
      {
        "date": "2012-02-08T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2012-001317"
      },
      {
        "date": "1900-01-01T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201111-480"
      },
      {
        "date": "2012-02-07T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201202-090"
      },
      {
        "date": "2012-02-03T20:55:01.907000",
        "db": "NVD",
        "id": "CVE-2011-4875"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2016-03-15T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2011-5108"
      },
      {
        "date": "2016-03-15T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2011-5110"
      },
      {
        "date": "2016-03-15T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2011-5103"
      },
      {
        "date": "2016-03-15T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2011-5107"
      },
      {
        "date": "2012-02-07T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2012-0465"
      },
      {
        "date": "2011-12-05T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2011-5105"
      },
      {
        "date": "2017-08-29T00:00:00",
        "db": "VULHUB",
        "id": "VHN-52820"
      },
      {
        "date": "2012-04-18T21:20:00",
        "db": "BID",
        "id": "50828"
      },
      {
        "date": "2012-02-08T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2012-001317"
      },
      {
        "date": "2011-11-30T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201111-480"
      },
      {
        "date": "2012-02-07T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201202-090"
      },
      {
        "date": "2025-04-11T00:51:21.963000",
        "db": "NVD",
        "id": "CVE-2011-4875"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201111-480"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201202-090"
      }
    ],
    "trust": 1.2
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Siemens SIMATIC WinCC Flexible Runtime \u0027HmiLoad.exe\u0027 Buffer Overflow Vulnerability",
    "sources": [
      {
        "db": "IVD",
        "id": "61050c40-1f7d-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5103"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Buffer overflow",
    "sources": [
      {
        "db": "IVD",
        "id": "61050c40-1f7d-11e6-abef-000c29c66e3d"
      },
      {
        "db": "IVD",
        "id": "5e37bfa8-1f7d-11e6-abef-000c29c66e3d"
      },
      {
        "db": "IVD",
        "id": "9fe8f34a-1f7d-11e6-abef-000c29c66e3d"
      },
      {
        "db": "IVD",
        "id": "28c3f672-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "IVD",
        "id": "9c31ed38-1f7d-11e6-abef-000c29c66e3d"
      },
      {
        "db": "IVD",
        "id": "9ef7b7be-1f7d-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201202-090"
      }
    ],
    "trust": 1.8
  }
}

VAR-201202-0164

Vulnerability from variot - Updated: 2025-04-11 22:49

HmiLoad in the runtime loader in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime, when Transfer Mode is enabled, allows remote attackers to cause a denial of service (application crash) by sending crafted data over TCP. Miniweb has a security vulnerability that allows an attacker to submit a specially crafted HTTP POST request to allow the server to access any illegal memory area while checking the extension of the requested file. Siemens SIMATIC WinCC is a multi-user system that provides complete monitoring and data acquisition (SCADA) functionality for the industrial sector, from single-user systems to redundant server and remote web client solutions. HmiLoad provides functions that read data and unicode strings with stack-based buffer overflows, allowing an attacker to exploit a vulnerability to execute arbitrary code. Siemens SIMATIC is an automation software in a single engineering environment. A security vulnerability exists in the Siemens SIMATIC WinCC HMI web server. When the transfer mode is enabled, the runtime loader listens on the 2308/TCP or 50523/TCP port. Since the incoming data is not fully verified, there are multiple denial of service attacks that can crash the program. A directory traversal vulnerability exists in the HmiLoad server that allows reading, writing, and deleting arbitrary files outside of the specified directory. Attackers can exploit these issues to execute arbitrary code in the context of the affected application, read/write or delete arbitrary files outside of the server root directory, or cause denial-of-service conditions; other attacks may also be possible

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201202-0164",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "simatic wincc flexible runtime",
        "scope": null,
        "trust": 3.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic wincc flexible sp2",
        "scope": "eq",
        "trust": 3.3,
        "vendor": "siemens",
        "version": "2008"
      },
      {
        "model": "simatic hmi panels",
        "scope": "eq",
        "trust": 2.4,
        "vendor": "siemens",
        "version": "mp"
      },
      {
        "model": "simatic hmi panels",
        "scope": "eq",
        "trust": 2.4,
        "vendor": "siemens",
        "version": "op"
      },
      {
        "model": "simatic hmi panels",
        "scope": "eq",
        "trust": 2.4,
        "vendor": "siemens",
        "version": "tp"
      },
      {
        "model": "simatic wincc flexible",
        "scope": "eq",
        "trust": 1.7,
        "vendor": "siemens",
        "version": "2008"
      },
      {
        "model": "simatic wincc flexible",
        "scope": "eq",
        "trust": 1.7,
        "vendor": "siemens",
        "version": "2007"
      },
      {
        "model": "simatic wincc flexible",
        "scope": "eq",
        "trust": 1.7,
        "vendor": "siemens",
        "version": "2005"
      },
      {
        "model": "simatic wincc flexible",
        "scope": "eq",
        "trust": 1.7,
        "vendor": "siemens",
        "version": "2004"
      },
      {
        "model": "simatic hmi panels",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "comfort_panels"
      },
      {
        "model": "wincc runtime advanced",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "v11"
      },
      {
        "model": "wincc",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "v11"
      },
      {
        "model": "wincc flexible",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "2004"
      },
      {
        "model": "wincc flexible",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "2005"
      },
      {
        "model": "simatic hmi panels",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "mobile_panels"
      },
      {
        "model": "simatic wincc",
        "scope": "eq",
        "trust": 1.4,
        "vendor": "siemens",
        "version": "v11"
      },
      {
        "model": "wincc flexible runtime",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "wincc flexible",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2007"
      },
      {
        "model": "wincc flexible",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2008"
      },
      {
        "model": "simatic hmi panels",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "siemens",
        "version": "comfort panels"
      },
      {
        "model": "simatic hmi panels",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "siemens",
        "version": "mobile panels"
      },
      {
        "model": "simatic wincc flexible rumtime",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic wincc runtime advanced",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "siemens",
        "version": "v11"
      },
      {
        "model": "simatic wincc runtime advanced",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic hmi panels",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic wincc",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "wincc flexible runtime",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic wincc flexible runtime",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic wincc flexible sp1",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "2008"
      },
      {
        "model": "simatic wincc flexible sp1",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "2005"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "wincc flexible",
        "version": "2004"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "wincc flexible",
        "version": "2005"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "wincc flexible",
        "version": "2007"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "wincc flexible",
        "version": "2008"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "wincc",
        "version": "v11"
      },
      {
        "model": "comfort panels",
        "scope": null,
        "trust": 0.2,
        "vendor": "simatic hmi panels",
        "version": null
      },
      {
        "model": "mobile panels",
        "scope": null,
        "trust": 0.2,
        "vendor": "simatic hmi panels",
        "version": null
      },
      {
        "model": "mp",
        "scope": null,
        "trust": 0.2,
        "vendor": "simatic hmi panels",
        "version": null
      },
      {
        "model": "op",
        "scope": null,
        "trust": 0.2,
        "vendor": "simatic hmi panels",
        "version": null
      },
      {
        "model": "tp",
        "scope": null,
        "trust": 0.2,
        "vendor": "simatic hmi panels",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "wincc runtime advanced",
        "version": "v11"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "wincc flexible runtime",
        "version": "*"
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "28b0bc2e-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5108"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5110"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5103"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5107"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2012-0467"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5105"
      },
      {
        "db": "BID",
        "id": "50828"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001319"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201202-092"
      },
      {
        "db": "NVD",
        "id": "CVE-2011-4877"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/a:siemens:simatic_hmi_panels",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/a:siemens:simatic_wincc_%28tia_portal%29",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/a:siemens:wincc_flexible",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/a:siemens:wincc_flexible_runtime",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/a:siemens:wincc_runtime_advanced",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001319"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Luigi Auriemma",
    "sources": [
      {
        "db": "BID",
        "id": "50828"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201111-480"
      }
    ],
    "trust": 0.9
  },
  "cve": "CVE-2011-4877",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.1,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 8.6,
            "id": "CVE-2011-4877",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "HIGH",
            "trust": 1.8,
            "vectorString": "AV:N/AC:M/Au:N/C:N/I:N/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "IVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.1,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 8.6,
            "id": "28b0bc2e-2354-11e6-abef-000c29c66e3d",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "HIGH",
            "trust": 0.2,
            "vectorString": "AV:N/AC:M/Au:N/C:N/I:N/A:C",
            "version": "2.9 [IVD]"
          },
          {
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.1,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 8.6,
            "id": "VHN-52822",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "HIGH",
            "trust": 0.1,
            "vectorString": "AV:N/AC:M/AU:N/C:N/I:N/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2011-4877",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "NVD",
            "id": "CVE-2011-4877",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201202-092",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "IVD",
            "id": "28b0bc2e-2354-11e6-abef-000c29c66e3d",
            "trust": 0.2,
            "value": "HIGH"
          },
          {
            "author": "VULHUB",
            "id": "VHN-52822",
            "trust": 0.1,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "28b0bc2e-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "VULHUB",
        "id": "VHN-52822"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001319"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201202-092"
      },
      {
        "db": "NVD",
        "id": "CVE-2011-4877"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "HmiLoad in the runtime loader in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime, when Transfer Mode is enabled, allows remote attackers to cause a denial of service (application crash) by sending crafted data over TCP. Miniweb has a security vulnerability that allows an attacker to submit a specially crafted HTTP POST request to allow the server to access any illegal memory area while checking the extension of the requested file. Siemens SIMATIC WinCC is a multi-user system that provides complete monitoring and data acquisition (SCADA) functionality for the industrial sector, from single-user systems to redundant server and remote web client solutions. HmiLoad provides functions that read data and unicode strings with stack-based buffer overflows, allowing an attacker to exploit a vulnerability to execute arbitrary code. Siemens SIMATIC is an automation software in a single engineering environment. A security vulnerability exists in the Siemens SIMATIC WinCC HMI web server. When the transfer mode is enabled, the runtime loader listens on the 2308/TCP or 50523/TCP port. Since the incoming data is not fully verified, there are multiple denial of service attacks that can crash the program. A directory traversal vulnerability exists in the HmiLoad server that allows reading, writing, and deleting arbitrary files outside of the specified directory. \nAttackers can exploit these issues to execute arbitrary code in the context of the affected application, read/write or delete arbitrary files outside of the server root directory, or cause denial-of-service conditions; other attacks may also be possible",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2011-4877"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001319"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5108"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5110"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5103"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5107"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2012-0467"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5105"
      },
      {
        "db": "BID",
        "id": "50828"
      },
      {
        "db": "IVD",
        "id": "28b0bc2e-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "VULHUB",
        "id": "VHN-52822"
      }
    ],
    "trust": 5.4
  },
  "exploit_availability": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/exploit_availability#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "reference": "https://www.scap.org.cn/vuln/vhn-52822",
        "trust": 0.1,
        "type": "unknown"
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-52822"
      }
    ]
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "BID",
        "id": "50828",
        "trust": 3.9
      },
      {
        "db": "NVD",
        "id": "CVE-2011-4877",
        "trust": 3.6
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-12-030-01",
        "trust": 3.4
      },
      {
        "db": "SIEMENS",
        "id": "SSA-345442",
        "trust": 1.7
      },
      {
        "db": "ICS CERT ALERT",
        "id": "ICS-ALERT-11-332-02A",
        "trust": 1.1
      },
      {
        "db": "ICS CERT ALERT",
        "id": "ICS-ALERT-11-332-02",
        "trust": 1.1
      },
      {
        "db": "EXPLOIT-DB",
        "id": "18166",
        "trust": 1.1
      },
      {
        "db": "OSVDB",
        "id": "77382",
        "trust": 1.1
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201202-092",
        "trust": 0.9
      },
      {
        "db": "CNVD",
        "id": "CNVD-2012-0467",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001319",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5108",
        "trust": 0.6
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5110",
        "trust": 0.6
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5103",
        "trust": 0.6
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5107",
        "trust": 0.6
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5105",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201111-480",
        "trust": 0.6
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-12-030-01A",
        "trust": 0.3
      },
      {
        "db": "IVD",
        "id": "28B0BC2E-2354-11E6-ABEF-000C29C66E3D",
        "trust": 0.2
      },
      {
        "db": "VULHUB",
        "id": "VHN-52822",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "28b0bc2e-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5108"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5110"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5103"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5107"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2012-0467"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5105"
      },
      {
        "db": "VULHUB",
        "id": "VHN-52822"
      },
      {
        "db": "BID",
        "id": "50828"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001319"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201111-480"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201202-092"
      },
      {
        "db": "NVD",
        "id": "CVE-2011-4877"
      }
    ]
  },
  "id": "VAR-201202-0164",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "IVD",
        "id": "28b0bc2e-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5108"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5110"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5103"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5107"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2012-0467"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5105"
      },
      {
        "db": "VULHUB",
        "id": "VHN-52822"
      }
    ],
    "trust": 4.568457485714285
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 3.8
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "28b0bc2e-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5108"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5110"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5103"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5107"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2012-0467"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5105"
      }
    ]
  },
  "last_update_date": "2025-04-11T22:49:48.378000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "SSA-345442",
        "trust": 0.8,
        "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf"
      },
      {
        "title": "\u30bd\u30ea\u30e5\u30fc\u30b7\u30e7\u30f3\u30d1\u30fc\u30c8\u30ca\u30fc",
        "trust": 0.8,
        "url": "http://www.automation.siemens.com/automation/jp/ja/solutionpartner/pages/default.aspx"
      },
      {
        "title": "Top Page",
        "trust": 0.8,
        "url": "http://www.siemens.com/entry/jp/ja/"
      },
      {
        "title": "Patch for Siemens SIMATIC WinCC Flexible Runtime \u0027HmiLoad.exe\u0027 file download vulnerability",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/72694"
      },
      {
        "title": "Siemens SIMATIC WinCC Flexible Runtime \u0027HmiLoad.exe\u0027 memory access vulnerability patch",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/72697"
      },
      {
        "title": "Siemens SIMATIC WinCC Flexible Runtime \u0027HmiLoad.exe\u0027 Buffer Overflow Vulnerability Patch",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/72705"
      },
      {
        "title": "Siemens SIMATIC WinCC Flexible Runtime \u0027HmiLoad.exe\u0027 service crash vulnerability patch",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/72689"
      },
      {
        "title": "Patch for Siemens SIMATIC WinCC HMI Denial of Service Attack Vulnerability (CNVD-2012-0467)",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/9073"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2011-5108"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5110"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5103"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5107"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2012-0467"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001319"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-20",
        "trust": 1.9
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-52822"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001319"
      },
      {
        "db": "NVD",
        "id": "CVE-2011-4877"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 3.9,
        "url": "http://aluigi.altervista.org/adv/winccflex_1-adv.txt"
      },
      {
        "trust": 3.4,
        "url": "http://www.us-cert.gov/control_systems/pdf/icsa-12-030-01.pdf"
      },
      {
        "trust": 1.7,
        "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf"
      },
      {
        "trust": 1.1,
        "url": "http://www.exploit-db.com/exploits/18166"
      },
      {
        "trust": 1.1,
        "url": "http://aluigi.org/adv/winccflex_1-adv.txt"
      },
      {
        "trust": 1.1,
        "url": "http://www.us-cert.gov/control_systems/pdf/ics-alert-11-332-02.pdf"
      },
      {
        "trust": 1.1,
        "url": "http://www.us-cert.gov/control_systems/pdf/ics-alert-11-332-02a.pdf"
      },
      {
        "trust": 1.1,
        "url": "http://www.osvdb.org/77382"
      },
      {
        "trust": 1.1,
        "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/71451"
      },
      {
        "trust": 0.8,
        "url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2011-4877"
      },
      {
        "trust": 0.8,
        "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2011-4877"
      },
      {
        "trust": 0.6,
        "url": "http://www.securityfocus.com/bid/50828"
      },
      {
        "trust": 0.3,
        "url": "http://www.automation.siemens.com/mcms/human-machine-interface/en/visualization-software/wincc-flexible/wincc-flexible-runtime/pages/default.aspx"
      },
      {
        "trust": 0.3,
        "url": "http://www.us-cert.gov/control_systems/pdf/icsa-12-030-01a.pdf"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2011-5108"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5110"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5103"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5107"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2012-0467"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5105"
      },
      {
        "db": "VULHUB",
        "id": "VHN-52822"
      },
      {
        "db": "BID",
        "id": "50828"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001319"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201111-480"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201202-092"
      },
      {
        "db": "NVD",
        "id": "CVE-2011-4877"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "IVD",
        "id": "28b0bc2e-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5108"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5110"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5103"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5107"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2012-0467"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5105"
      },
      {
        "db": "VULHUB",
        "id": "VHN-52822"
      },
      {
        "db": "BID",
        "id": "50828"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001319"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201111-480"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201202-092"
      },
      {
        "db": "NVD",
        "id": "CVE-2011-4877"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2012-02-07T00:00:00",
        "db": "IVD",
        "id": "28b0bc2e-2354-11e6-abef-000c29c66e3d"
      },
      {
        "date": "2011-12-05T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2011-5108"
      },
      {
        "date": "2011-12-05T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2011-5110"
      },
      {
        "date": "2011-12-05T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2011-5103"
      },
      {
        "date": "2011-12-05T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2011-5107"
      },
      {
        "date": "2012-02-07T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2012-0467"
      },
      {
        "date": "2011-12-05T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2011-5105"
      },
      {
        "date": "2012-02-03T00:00:00",
        "db": "VULHUB",
        "id": "VHN-52822"
      },
      {
        "date": "2011-11-28T00:00:00",
        "db": "BID",
        "id": "50828"
      },
      {
        "date": "2012-02-08T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2012-001319"
      },
      {
        "date": "1900-01-01T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201111-480"
      },
      {
        "date": "2012-02-07T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201202-092"
      },
      {
        "date": "2012-02-03T20:55:01.983000",
        "db": "NVD",
        "id": "CVE-2011-4877"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2016-03-15T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2011-5108"
      },
      {
        "date": "2016-03-15T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2011-5110"
      },
      {
        "date": "2016-03-15T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2011-5103"
      },
      {
        "date": "2016-03-15T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2011-5107"
      },
      {
        "date": "2012-02-07T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2012-0467"
      },
      {
        "date": "2011-12-05T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2011-5105"
      },
      {
        "date": "2017-08-29T00:00:00",
        "db": "VULHUB",
        "id": "VHN-52822"
      },
      {
        "date": "2012-04-18T21:20:00",
        "db": "BID",
        "id": "50828"
      },
      {
        "date": "2012-02-08T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2012-001319"
      },
      {
        "date": "2011-11-30T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201111-480"
      },
      {
        "date": "2012-02-07T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201202-092"
      },
      {
        "date": "2025-04-11T00:51:21.963000",
        "db": "NVD",
        "id": "CVE-2011-4877"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201111-480"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201202-092"
      }
    ],
    "trust": 1.2
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "plural  Siemens Product  HmiLoad Service disruption in  ( Application crash ) Vulnerabilities",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001319"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Input validation",
    "sources": [
      {
        "db": "IVD",
        "id": "28b0bc2e-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201202-092"
      }
    ],
    "trust": 0.8
  }
}

VAR-201202-0043

Vulnerability from variot - Updated: 2025-04-11 22:49

The HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime generates predictable authentication tokens for cookies, which makes it easier for remote attackers to bypass authentication via a crafted cookie. plural Siemens Product HMI Web The server Cookie There is a vulnerability that prevents authentication because it generates a predictable authentication token.Skillfully crafted by a third party Cookie Authentication may be bypassed. Siemens SIMATIC WinCC is a multi-user system that provides complete monitoring and data acquisition (SCADA) functionality for the industrial sector, from single-user systems to redundant server and remote web client solutions. Multiple Siemens SIMATIC products have security vulnerabilities, and the insecure generation of authentication tokens (session COOKIE guesses) allows an attacker to bypass authentication checks and increase privileges without a username and password. An attacker can exploit these issues to bypass intended security restrictions and gain access to the affected application. Successfully exploiting these issues may lead to further attacks. The Siemens SIMATIC HMI product family is used as the human-machine interface between the corresponding PLC and the operator

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201202-0043",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "simatic hmi panels",
        "scope": "eq",
        "trust": 2.4,
        "vendor": "siemens",
        "version": "mp"
      },
      {
        "model": "simatic hmi panels",
        "scope": "eq",
        "trust": 2.4,
        "vendor": "siemens",
        "version": "op"
      },
      {
        "model": "simatic hmi panels",
        "scope": "eq",
        "trust": 2.4,
        "vendor": "siemens",
        "version": "tp"
      },
      {
        "model": "simatic wincc flexible",
        "scope": "eq",
        "trust": 1.7,
        "vendor": "siemens",
        "version": "2007"
      },
      {
        "model": "simatic wincc flexible",
        "scope": "eq",
        "trust": 1.7,
        "vendor": "siemens",
        "version": "2005"
      },
      {
        "model": "simatic wincc flexible",
        "scope": "eq",
        "trust": 1.7,
        "vendor": "siemens",
        "version": "2004"
      },
      {
        "model": "simatic hmi panels",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "comfort_panels"
      },
      {
        "model": "wincc runtime advanced",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "v11"
      },
      {
        "model": "wincc",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "v11"
      },
      {
        "model": "simatic hmi panels",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "mobile_panels"
      },
      {
        "model": "wincc flexible",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2004"
      },
      {
        "model": "wincc flexible runtime",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "wincc flexible",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2007"
      },
      {
        "model": "wincc",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "v11"
      },
      {
        "model": "wincc flexible",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2005"
      },
      {
        "model": "wincc flexible",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2008"
      },
      {
        "model": "simatic wincc flexible",
        "scope": "eq",
        "trust": 0.9,
        "vendor": "siemens",
        "version": "2008"
      },
      {
        "model": "simatic wincc flexible sp1",
        "scope": "eq",
        "trust": 0.9,
        "vendor": "siemens",
        "version": "2008"
      },
      {
        "model": "simatic wincc flexible sp2",
        "scope": "eq",
        "trust": 0.9,
        "vendor": "siemens",
        "version": "2008"
      },
      {
        "model": "simatic wincc flexible sp1",
        "scope": "eq",
        "trust": 0.9,
        "vendor": "siemens",
        "version": "2005"
      },
      {
        "model": "simatic wincc flexible runtime",
        "scope": "eq",
        "trust": 0.9,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic hmi panels",
        "scope": "eq",
        "trust": 0.9,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic wincc sp2",
        "scope": "eq",
        "trust": 0.9,
        "vendor": "siemens",
        "version": "v11"
      },
      {
        "model": "simatic wincc sp1",
        "scope": "eq",
        "trust": 0.9,
        "vendor": "siemens",
        "version": "v11"
      },
      {
        "model": "simatic wincc",
        "scope": "eq",
        "trust": 0.9,
        "vendor": "siemens",
        "version": "v11"
      },
      {
        "model": "simatic wincc",
        "scope": "eq",
        "trust": 0.9,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic hmi panels",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "siemens",
        "version": "comfort panels"
      },
      {
        "model": "simatic hmi panels",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "siemens",
        "version": "mobile panels"
      },
      {
        "model": "simatic wincc",
        "scope": "lt",
        "trust": 0.8,
        "vendor": "siemens",
        "version": "v11 sp2 update 1"
      },
      {
        "model": "simatic wincc flexible",
        "scope": "lt",
        "trust": 0.8,
        "vendor": "siemens",
        "version": "2008 sp3"
      },
      {
        "model": "simatic wincc flexible rumtime",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic wincc runtime advanced",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "siemens",
        "version": "v11"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.6,
        "vendor": "wincc flexible",
        "version": "2008"
      },
      {
        "model": "wincc flexible runtime",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.4,
        "vendor": "wincc",
        "version": "v11"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "wincc flexible",
        "version": "2004"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "wincc flexible",
        "version": "2005"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "wincc flexible",
        "version": "2007"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "wincc",
        "version": "*"
      },
      {
        "model": "comfort panels",
        "scope": null,
        "trust": 0.2,
        "vendor": "simatic hmi panels",
        "version": null
      },
      {
        "model": "mobile panels",
        "scope": null,
        "trust": 0.2,
        "vendor": "simatic hmi panels",
        "version": null
      },
      {
        "model": "mp",
        "scope": null,
        "trust": 0.2,
        "vendor": "simatic hmi panels",
        "version": null
      },
      {
        "model": "op",
        "scope": null,
        "trust": 0.2,
        "vendor": "simatic hmi panels",
        "version": null
      },
      {
        "model": "tp",
        "scope": null,
        "trust": 0.2,
        "vendor": "simatic hmi panels",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "wincc runtime advanced",
        "version": "v11"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "wincc flexible runtime",
        "version": "*"
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "28828750-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5448"
      },
      {
        "db": "BID",
        "id": "51177"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001310"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201112-422"
      },
      {
        "db": "NVD",
        "id": "CVE-2011-4508"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/a:siemens:simatic_hmi_panels",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/a:siemens:simatic_wincc_%28tia_portal%29",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/a:siemens:wincc_flexible",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/a:siemens:wincc_flexible_runtime",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/a:siemens:wincc_runtime_advanced",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001310"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Billy Rios and Terry McCorkle",
    "sources": [
      {
        "db": "BID",
        "id": "51177"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201112-422"
      }
    ],
    "trust": 0.9
  },
  "cve": "CVE-2011-4508",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "COMPLETE",
            "baseScore": 9.3,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 8.6,
            "id": "CVE-2011-4508",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 1.0,
            "vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "Low",
            "accessVector": "Network",
            "authentication": "None",
            "author": "NVD",
            "availabilityImpact": "Complete",
            "baseScore": 10.0,
            "confidentialityImpact": "Complete",
            "exploitabilityScore": null,
            "id": "CVE-2011-4508",
            "impactScore": null,
            "integrityImpact": "Complete",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "High",
            "trust": 0.8,
            "userInteractionRequired": null,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "IVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 9.3,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 8.6,
            "id": "28828750-2354-11e6-abef-000c29c66e3d",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.2,
            "vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C",
            "version": "2.9 [IVD]"
          },
          {
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "COMPLETE",
            "baseScore": 9.3,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 8.6,
            "id": "VHN-52453",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.1,
            "vectorString": "AV:N/AC:M/AU:N/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2011-4508",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "NVD",
            "id": "CVE-2011-4508",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201112-422",
            "trust": 0.6,
            "value": "CRITICAL"
          },
          {
            "author": "IVD",
            "id": "28828750-2354-11e6-abef-000c29c66e3d",
            "trust": 0.2,
            "value": "CRITICAL"
          },
          {
            "author": "VULHUB",
            "id": "VHN-52453",
            "trust": 0.1,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "28828750-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "VULHUB",
        "id": "VHN-52453"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001310"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201112-422"
      },
      {
        "db": "NVD",
        "id": "CVE-2011-4508"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "The HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime generates predictable authentication tokens for cookies, which makes it easier for remote attackers to bypass authentication via a crafted cookie. plural Siemens Product HMI Web The server Cookie There is a vulnerability that prevents authentication because it generates a predictable authentication token.Skillfully crafted by a third party Cookie Authentication may be bypassed. Siemens SIMATIC WinCC is a multi-user system that provides complete monitoring and data acquisition (SCADA) functionality for the industrial sector, from single-user systems to redundant server and remote web client solutions. Multiple Siemens SIMATIC products have security vulnerabilities, and the insecure generation of authentication tokens (session COOKIE guesses) allows an attacker to bypass authentication checks and increase privileges without a username and password. \nAn attacker can exploit these issues to bypass intended security   restrictions and gain access to the affected application.  Successfully   exploiting these issues may lead to further attacks. The Siemens SIMATIC HMI product family is used as the human-machine interface between the corresponding PLC and the operator",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2011-4508"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001310"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5448"
      },
      {
        "db": "BID",
        "id": "51177"
      },
      {
        "db": "IVD",
        "id": "28828750-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "VULHUB",
        "id": "VHN-52453"
      }
    ],
    "trust": 2.7
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2011-4508",
        "trust": 3.6
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-12-030-01",
        "trust": 2.5
      },
      {
        "db": "SIEMENS",
        "id": "SSA-345442",
        "trust": 1.7
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201112-422",
        "trust": 0.9
      },
      {
        "db": "BID",
        "id": "51177",
        "trust": 0.9
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5448",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001310",
        "trust": 0.8
      },
      {
        "db": "NSFOCUS",
        "id": "18390",
        "trust": 0.6
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-11-356-01",
        "trust": 0.3
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-12-030-01A",
        "trust": 0.3
      },
      {
        "db": "IVD",
        "id": "28828750-2354-11E6-ABEF-000C29C66E3D",
        "trust": 0.2
      },
      {
        "db": "VULHUB",
        "id": "VHN-52453",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "28828750-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5448"
      },
      {
        "db": "VULHUB",
        "id": "VHN-52453"
      },
      {
        "db": "BID",
        "id": "51177"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001310"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201112-422"
      },
      {
        "db": "NVD",
        "id": "CVE-2011-4508"
      }
    ]
  },
  "id": "VAR-201202-0043",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "IVD",
        "id": "28828750-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5448"
      },
      {
        "db": "VULHUB",
        "id": "VHN-52453"
      }
    ],
    "trust": 1.575178075
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "28828750-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5448"
      }
    ]
  },
  "last_update_date": "2025-04-11T22:49:48.326000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "SSA-345442",
        "trust": 0.8,
        "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf"
      },
      {
        "title": "\u30bd\u30ea\u30e5\u30fc\u30b7\u30e7\u30f3\u30d1\u30fc\u30c8\u30ca\u30fc",
        "trust": 0.8,
        "url": "http://www.automation.siemens.com/automation/jp/ja/solutionpartner/pages/default.aspx"
      },
      {
        "title": "Top Page",
        "trust": 0.8,
        "url": "http://www.siemens.com/entry/jp/ja/"
      },
      {
        "title": "Patch for multiple Siemens SIMATIC Product Verification Bypass Vulnerabilities (CNVD-2011-5448)",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/72707"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2011-5448"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001310"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-287",
        "trust": 1.9
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-52453"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001310"
      },
      {
        "db": "NVD",
        "id": "CVE-2011-4508"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.5,
        "url": "http://www.us-cert.gov/control_systems/pdf/icsa-12-030-01.pdf"
      },
      {
        "trust": 1.7,
        "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf"
      },
      {
        "trust": 0.8,
        "url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2011-4508"
      },
      {
        "trust": 0.8,
        "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2011-4508"
      },
      {
        "trust": 0.6,
        "url": "http://xs-sniper.com/blog/2011/12/20/the-siemens-simatic-remote-authentication-bypass-that-doesnt-exist/http"
      },
      {
        "trust": 0.6,
        "url": "http://www.securityfocus.com/bid/51177"
      },
      {
        "trust": 0.6,
        "url": "http://www.nsfocus.net/vulndb/18390"
      },
      {
        "trust": 0.3,
        "url": "http://www.automation.siemens.com/mcms/human-machine-interface/en/visualization-software/pages/default.aspx"
      },
      {
        "trust": 0.3,
        "url": "http://www.automation.siemens.com/mcms/human-machine-interface/en/visualization-software/wincc-flexible/wincc-flexible-runtime/user-interface/pages/default.aspx"
      },
      {
        "trust": 0.3,
        "url": "http://xs-sniper.com/blog/2011/12/20/the-siemens-simatic-remote-authentication-bypass-that-doesnt-exist/"
      },
      {
        "trust": 0.3,
        "url": "http://www.us-cert.gov/control_systems/pdf/icsa-12-030-01a.pdf"
      },
      {
        "trust": 0.3,
        "url": "http://www.us-cert.gov/control_systems/pdf/icsa-11-356-01.pdf"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2011-5448"
      },
      {
        "db": "VULHUB",
        "id": "VHN-52453"
      },
      {
        "db": "BID",
        "id": "51177"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001310"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201112-422"
      },
      {
        "db": "NVD",
        "id": "CVE-2011-4508"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "IVD",
        "id": "28828750-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2011-5448"
      },
      {
        "db": "VULHUB",
        "id": "VHN-52453"
      },
      {
        "db": "BID",
        "id": "51177"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001310"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201112-422"
      },
      {
        "db": "NVD",
        "id": "CVE-2011-4508"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2011-12-26T00:00:00",
        "db": "IVD",
        "id": "28828750-2354-11e6-abef-000c29c66e3d"
      },
      {
        "date": "2011-12-26T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2011-5448"
      },
      {
        "date": "2012-02-03T00:00:00",
        "db": "VULHUB",
        "id": "VHN-52453"
      },
      {
        "date": "2011-12-22T00:00:00",
        "db": "BID",
        "id": "51177"
      },
      {
        "date": "2012-02-08T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2012-001310"
      },
      {
        "date": "1900-01-01T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201112-422"
      },
      {
        "date": "2012-02-03T20:55:01.250000",
        "db": "NVD",
        "id": "CVE-2011-4508"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2016-03-15T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2011-5448"
      },
      {
        "date": "2012-02-07T00:00:00",
        "db": "VULHUB",
        "id": "VHN-52453"
      },
      {
        "date": "2012-04-18T21:20:00",
        "db": "BID",
        "id": "51177"
      },
      {
        "date": "2012-02-08T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2012-001310"
      },
      {
        "date": "2012-01-05T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201112-422"
      },
      {
        "date": "2025-04-11T00:51:21.963000",
        "db": "NVD",
        "id": "CVE-2011-4508"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201112-422"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "plural  Siemens Product  HMI Web Vulnerability that prevents authentication on the server",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001310"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "authorization issue",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201112-422"
      }
    ],
    "trust": 0.6
  }
}

VAR-201202-0165

Vulnerability from variot - Updated: 2025-04-11 22:49

Directory traversal vulnerability in miniweb.exe in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allows remote attackers to read arbitrary files via a ..%5c (dot dot backslash) in a URI. plural Siemens Product HMI Web Server miniweb.exe Contains a directory traversal vulnerability.By a third party ..%5c ( Dot dot backslash ) including URI Any file may be read via. Siemens SIMATIC is an automation software in a single engineering environment. A security vulnerability exists in the Siemens SIMATIC WinCC HMI web server. The HMI web server listening on TCP ports 80 and 443 does not correctly verify the URL in the HTTP request, and builds a URL containing a specially crafted slash to perform a directory traversal attack and read any file in the file system. Siemens SIMATIC WinCC is prone to an HTTP-header-injection issue, a directory-traversal issue, and an arbitrary memory-read access issue because the application fails to properly sanitize user-supplied input. A remote attacker can exploit these issues to gain elevated privileges, obtain sensitive information, or cause denial-of-service conditions. A remote attacker can exploit this vulnerability to read arbitrary files by means of ../ (dotted backslashes) in the URL

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201202-0165",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "simatic hmi panels",
        "scope": "eq",
        "trust": 2.4,
        "vendor": "siemens",
        "version": "mp"
      },
      {
        "model": "simatic hmi panels",
        "scope": "eq",
        "trust": 2.4,
        "vendor": "siemens",
        "version": "tp"
      },
      {
        "model": "simatic hmi panels",
        "scope": "eq",
        "trust": 2.4,
        "vendor": "siemens",
        "version": "op"
      },
      {
        "model": "simatic wincc flexible",
        "scope": "eq",
        "trust": 1.7,
        "vendor": "siemens",
        "version": "2005"
      },
      {
        "model": "simatic wincc flexible",
        "scope": "eq",
        "trust": 1.7,
        "vendor": "siemens",
        "version": "2004"
      },
      {
        "model": "simatic wincc flexible",
        "scope": "eq",
        "trust": 1.7,
        "vendor": "siemens",
        "version": "2007"
      },
      {
        "model": "simatic hmi panels",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "comfort_panels"
      },
      {
        "model": "wincc runtime advanced",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "v11"
      },
      {
        "model": "wincc",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "v11"
      },
      {
        "model": "simatic hmi panels",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "mobile_panels"
      },
      {
        "model": "wincc flexible",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2004"
      },
      {
        "model": "wincc flexible runtime",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "wincc flexible",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2007"
      },
      {
        "model": "wincc",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "v11"
      },
      {
        "model": "wincc flexible",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2005"
      },
      {
        "model": "wincc flexible",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2008"
      },
      {
        "model": "simatic wincc flexible",
        "scope": "eq",
        "trust": 0.9,
        "vendor": "siemens",
        "version": "2008"
      },
      {
        "model": "simatic wincc",
        "scope": "eq",
        "trust": 0.9,
        "vendor": "siemens",
        "version": "v11"
      },
      {
        "model": "simatic wincc",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "siemens",
        "version": "sp2 update 1"
      },
      {
        "model": "simatic wincc",
        "scope": "lt",
        "trust": 0.8,
        "vendor": "siemens",
        "version": "v11\\\\"
      },
      {
        "model": "simatic hmi panels",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "siemens",
        "version": "comfort panels"
      },
      {
        "model": "simatic wincc runtime advanced",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "siemens",
        "version": "v11"
      },
      {
        "model": "simatic hmi panels",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "siemens",
        "version": "mobile panels"
      },
      {
        "model": "simatic wincc flexible rumtime",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.6,
        "vendor": "wincc flexible",
        "version": "2008"
      },
      {
        "model": "simatic hmi panels",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic wincc flexible runtime",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic wincc runtime advanced",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic wincc",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "wincc flexible runtime",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.4,
        "vendor": "wincc",
        "version": "v11"
      },
      {
        "model": "simatic wincc flexible runtime",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic wincc runtime advanced",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic wincc",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic hmi panels",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "wincc flexible",
        "version": "2004"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "wincc flexible",
        "version": "2005"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "wincc flexible",
        "version": "2007"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "wincc",
        "version": "*"
      },
      {
        "model": "comfort panels",
        "scope": null,
        "trust": 0.2,
        "vendor": "simatic hmi panels",
        "version": null
      },
      {
        "model": "mobile panels",
        "scope": null,
        "trust": 0.2,
        "vendor": "simatic hmi panels",
        "version": null
      },
      {
        "model": "mp",
        "scope": null,
        "trust": 0.2,
        "vendor": "simatic hmi panels",
        "version": null
      },
      {
        "model": "op",
        "scope": null,
        "trust": 0.2,
        "vendor": "simatic hmi panels",
        "version": null
      },
      {
        "model": "tp",
        "scope": null,
        "trust": 0.2,
        "vendor": "simatic hmi panels",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "wincc runtime advanced",
        "version": "v11"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "wincc flexible runtime",
        "version": "*"
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "2848847e-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2012-0468"
      },
      {
        "db": "BID",
        "id": "51836"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001320"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201202-093"
      },
      {
        "db": "NVD",
        "id": "CVE-2011-4878"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/a:siemens:simatic_hmi_panels",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/a:siemens:simatic_wincc_%28tia_portal%29",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/a:siemens:wincc_flexible",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/a:siemens:wincc_flexible_runtime",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/a:siemens:wincc_runtime_advanced",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001320"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "ICS-CERT",
    "sources": [
      {
        "db": "BID",
        "id": "51836"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201202-093"
      }
    ],
    "trust": 0.9
  },
  "cve": "CVE-2011-4878",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "NONE",
            "baseScore": 7.8,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "CVE-2011-4878",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "HIGH",
            "trust": 1.8,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:N/A:N",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "IVD",
            "availabilityImpact": "NONE",
            "baseScore": 7.8,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "2848847e-2354-11e6-abef-000c29c66e3d",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "HIGH",
            "trust": 0.2,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:N/A:N",
            "version": "2.9 [IVD]"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "NONE",
            "baseScore": 7.8,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "VHN-52823",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "HIGH",
            "trust": 0.1,
            "vectorString": "AV:N/AC:L/AU:N/C:C/I:N/A:N",
            "version": "2.0"
          }
        ],
        "cvssV3": [],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2011-4878",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "NVD",
            "id": "CVE-2011-4878",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201202-093",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "IVD",
            "id": "2848847e-2354-11e6-abef-000c29c66e3d",
            "trust": 0.2,
            "value": "HIGH"
          },
          {
            "author": "VULHUB",
            "id": "VHN-52823",
            "trust": 0.1,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "2848847e-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "VULHUB",
        "id": "VHN-52823"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001320"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201202-093"
      },
      {
        "db": "NVD",
        "id": "CVE-2011-4878"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Directory traversal vulnerability in miniweb.exe in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allows remote attackers to read arbitrary files via a ..%5c (dot dot backslash) in a URI. plural Siemens Product HMI Web Server miniweb.exe Contains a directory traversal vulnerability.By a third party ..%5c ( Dot dot backslash ) including URI Any file may be read via. Siemens SIMATIC is an automation software in a single engineering environment. A security vulnerability exists in the Siemens SIMATIC WinCC HMI web server. The HMI web server listening on TCP ports 80 and 443 does not correctly verify the URL in the HTTP request, and builds a URL containing a specially crafted slash to perform a directory traversal attack and read any file in the file system. Siemens SIMATIC WinCC is prone to an HTTP-header-injection issue, a directory-traversal issue, and an arbitrary memory-read access issue because the application fails to properly sanitize user-supplied input. \nA remote attacker can exploit these issues to gain elevated privileges, obtain sensitive information, or cause denial-of-service conditions. A remote attacker can exploit this vulnerability to read arbitrary files by means of ../ (dotted backslashes) in the URL",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2011-4878"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001320"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2012-0468"
      },
      {
        "db": "BID",
        "id": "51836"
      },
      {
        "db": "IVD",
        "id": "2848847e-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "VULHUB",
        "id": "VHN-52823"
      }
    ],
    "trust": 2.7
  },
  "exploit_availability": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/exploit_availability#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "reference": "https://www.scap.org.cn/vuln/vhn-52823",
        "trust": 0.1,
        "type": "unknown"
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-52823"
      }
    ]
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2011-4878",
        "trust": 3.6
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-12-030-01",
        "trust": 3.4
      },
      {
        "db": "SIEMENS",
        "id": "SSA-345442",
        "trust": 1.7
      },
      {
        "db": "ICS CERT ALERT",
        "id": "ICS-ALERT-11-332-02A",
        "trust": 1.1
      },
      {
        "db": "ICS CERT ALERT",
        "id": "ICS-ALERT-11-332-02",
        "trust": 1.1
      },
      {
        "db": "EXPLOIT-DB",
        "id": "18166",
        "trust": 1.1
      },
      {
        "db": "OSVDB",
        "id": "77383",
        "trust": 1.1
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201202-093",
        "trust": 0.9
      },
      {
        "db": "CNVD",
        "id": "CNVD-2012-0468",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001320",
        "trust": 0.8
      },
      {
        "db": "NSFOCUS",
        "id": "18633",
        "trust": 0.6
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-12-030-01A",
        "trust": 0.3
      },
      {
        "db": "BID",
        "id": "51836",
        "trust": 0.3
      },
      {
        "db": "IVD",
        "id": "2848847E-2354-11E6-ABEF-000C29C66E3D",
        "trust": 0.2
      },
      {
        "db": "VULHUB",
        "id": "VHN-52823",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "2848847e-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2012-0468"
      },
      {
        "db": "VULHUB",
        "id": "VHN-52823"
      },
      {
        "db": "BID",
        "id": "51836"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001320"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201202-093"
      },
      {
        "db": "NVD",
        "id": "CVE-2011-4878"
      }
    ]
  },
  "id": "VAR-201202-0165",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "IVD",
        "id": "2848847e-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2012-0468"
      },
      {
        "db": "VULHUB",
        "id": "VHN-52823"
      }
    ],
    "trust": 1.5153960400000002
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "2848847e-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2012-0468"
      }
    ]
  },
  "last_update_date": "2025-04-11T22:49:48.283000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "SSA-345442",
        "trust": 0.8,
        "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf"
      },
      {
        "title": "\u30bd\u30ea\u30e5\u30fc\u30b7\u30e7\u30f3\u30d1\u30fc\u30c8\u30ca\u30fc",
        "trust": 0.8,
        "url": "http://www.automation.siemens.com/automation/jp/ja/solutionpartner/pages/default.aspx"
      },
      {
        "title": "Top Page",
        "trust": 0.8,
        "url": "http://www.siemens.com/entry/jp/ja/"
      },
      {
        "title": "Patch for Siemens SIMATIC WinCC HMI Directory Traversal Vulnerability (CNVD-2012-0468)",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/9074"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2012-0468"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001320"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-22",
        "trust": 1.9
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-52823"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001320"
      },
      {
        "db": "NVD",
        "id": "CVE-2011-4878"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 3.4,
        "url": "http://www.us-cert.gov/control_systems/pdf/icsa-12-030-01.pdf"
      },
      {
        "trust": 1.7,
        "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf"
      },
      {
        "trust": 1.1,
        "url": "http://www.exploit-db.com/exploits/18166"
      },
      {
        "trust": 1.1,
        "url": "http://aluigi.org/adv/winccflex_1-adv.txt"
      },
      {
        "trust": 1.1,
        "url": "http://www.us-cert.gov/control_systems/pdf/ics-alert-11-332-02.pdf"
      },
      {
        "trust": 1.1,
        "url": "http://www.us-cert.gov/control_systems/pdf/ics-alert-11-332-02a.pdf"
      },
      {
        "trust": 1.1,
        "url": "http://www.osvdb.org/77383"
      },
      {
        "trust": 1.1,
        "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/71452"
      },
      {
        "trust": 0.8,
        "url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2011-4878"
      },
      {
        "trust": 0.8,
        "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2011-4878"
      },
      {
        "trust": 0.6,
        "url": "http://aluigi.altervista.org/adv/winccflex_1-adv.txt"
      },
      {
        "trust": 0.6,
        "url": "http://www.nsfocus.net/vulndb/18633"
      },
      {
        "trust": 0.3,
        "url": "http://www.automation.siemens.com/mcms/human-machine-interface/en/visualization-software/scada/pages/default.aspx"
      },
      {
        "trust": 0.3,
        "url": "http://www.us-cert.gov/control_systems/pdf/icsa-12-030-01a.pdf"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2012-0468"
      },
      {
        "db": "VULHUB",
        "id": "VHN-52823"
      },
      {
        "db": "BID",
        "id": "51836"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001320"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201202-093"
      },
      {
        "db": "NVD",
        "id": "CVE-2011-4878"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "IVD",
        "id": "2848847e-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2012-0468"
      },
      {
        "db": "VULHUB",
        "id": "VHN-52823"
      },
      {
        "db": "BID",
        "id": "51836"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001320"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201202-093"
      },
      {
        "db": "NVD",
        "id": "CVE-2011-4878"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2012-02-07T00:00:00",
        "db": "IVD",
        "id": "2848847e-2354-11e6-abef-000c29c66e3d"
      },
      {
        "date": "2012-02-07T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2012-0468"
      },
      {
        "date": "2012-02-03T00:00:00",
        "db": "VULHUB",
        "id": "VHN-52823"
      },
      {
        "date": "2012-02-02T00:00:00",
        "db": "BID",
        "id": "51836"
      },
      {
        "date": "2012-02-08T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2012-001320"
      },
      {
        "date": "2012-02-07T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201202-093"
      },
      {
        "date": "2012-02-03T20:55:02.030000",
        "db": "NVD",
        "id": "CVE-2011-4878"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2012-02-07T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2012-0468"
      },
      {
        "date": "2017-08-29T00:00:00",
        "db": "VULHUB",
        "id": "VHN-52823"
      },
      {
        "date": "2012-04-18T21:20:00",
        "db": "BID",
        "id": "51836"
      },
      {
        "date": "2012-02-08T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2012-001320"
      },
      {
        "date": "2012-02-07T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201202-093"
      },
      {
        "date": "2025-04-11T00:51:21.963000",
        "db": "NVD",
        "id": "CVE-2011-4878"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201202-093"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "plural  Siemens Product  HMI Web Server traversal vulnerability",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001320"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Path traversal",
    "sources": [
      {
        "db": "IVD",
        "id": "2848847e-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201202-093"
      }
    ],
    "trust": 0.8
  }
}

VAR-201202-0045

Vulnerability from variot - Updated: 2025-04-11 22:49

Cross-site scripting (XSS) vulnerability in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allows remote attackers to inject arbitrary web script or HTML via unspecified vectors, a different vulnerability than CVE-2011-4511. plural Siemens Product HMI Web The server contains a cross-site scripting vulnerability. This vulnerability CVE-2011-4511 Is a different vulnerability.By any third party Web Script or HTML May be inserted. Siemens SIMATIC is an automation software in a single engineering environment. The SIMATIC HMI Smart Options web server has two separate cross-site scripting attacks that allow elevation of privilege, stealing data or corrupting services. SIMATIC HMI is prone to multiple unspecified cross-site scripting vulnerabilities because it fails to properly sanitize user-supplied input. An attacker may leverage these issues to execute arbitrary script code in the browser of an unsuspecting user in the context of the affected site. This can allow the attacker to steal cookie-based authentication credentials and launch other attacks

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201202-0045",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "simatic hmi panels",
        "scope": "eq",
        "trust": 2.4,
        "vendor": "siemens",
        "version": "mp"
      },
      {
        "model": "simatic hmi panels",
        "scope": "eq",
        "trust": 2.4,
        "vendor": "siemens",
        "version": "op"
      },
      {
        "model": "simatic hmi panels",
        "scope": "eq",
        "trust": 2.4,
        "vendor": "siemens",
        "version": "tp"
      },
      {
        "model": "simatic hmi panels",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "comfort_panels"
      },
      {
        "model": "wincc runtime advanced",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "v11"
      },
      {
        "model": "wincc",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "v11"
      },
      {
        "model": "simatic hmi panels",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "mobile_panels"
      },
      {
        "model": "simatic wincc flexible",
        "scope": "eq",
        "trust": 1.4,
        "vendor": "siemens",
        "version": "2007"
      },
      {
        "model": "simatic wincc flexible",
        "scope": "eq",
        "trust": 1.4,
        "vendor": "siemens",
        "version": "2005"
      },
      {
        "model": "simatic wincc flexible",
        "scope": "eq",
        "trust": 1.4,
        "vendor": "siemens",
        "version": "2004"
      },
      {
        "model": "wincc flexible",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2004"
      },
      {
        "model": "wincc flexible runtime",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "wincc flexible",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2007"
      },
      {
        "model": "wincc",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "v11"
      },
      {
        "model": "wincc flexible",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2005"
      },
      {
        "model": "wincc flexible",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2008"
      },
      {
        "model": "simatic hmi panels",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "siemens",
        "version": "comfort panels"
      },
      {
        "model": "simatic hmi panels",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "siemens",
        "version": "mobile panels"
      },
      {
        "model": "simatic wincc",
        "scope": "lt",
        "trust": 0.8,
        "vendor": "siemens",
        "version": "v11 sp2 update 1"
      },
      {
        "model": "simatic wincc flexible",
        "scope": "lt",
        "trust": 0.8,
        "vendor": "siemens",
        "version": "2008 sp3"
      },
      {
        "model": "simatic wincc flexible rumtime",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic wincc runtime advanced",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "siemens",
        "version": "v11"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.6,
        "vendor": "wincc flexible",
        "version": "2008"
      },
      {
        "model": "simatic wincc flexible runtime",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic wincc runtime advanced",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic wincc flexible",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "2008"
      },
      {
        "model": "simatic hmi panels",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic wincc",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic wincc",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v11"
      },
      {
        "model": "wincc flexible runtime",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.4,
        "vendor": "wincc",
        "version": "v11"
      },
      {
        "model": "simatic hmi smart options",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic hmi",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "wincc flexible",
        "version": "2004"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "wincc flexible",
        "version": "2005"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "wincc flexible",
        "version": "2007"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "wincc",
        "version": "*"
      },
      {
        "model": "comfort panels",
        "scope": null,
        "trust": 0.2,
        "vendor": "simatic hmi panels",
        "version": null
      },
      {
        "model": "mobile panels",
        "scope": null,
        "trust": 0.2,
        "vendor": "simatic hmi panels",
        "version": null
      },
      {
        "model": "mp",
        "scope": null,
        "trust": 0.2,
        "vendor": "simatic hmi panels",
        "version": null
      },
      {
        "model": "op",
        "scope": null,
        "trust": 0.2,
        "vendor": "simatic hmi panels",
        "version": null
      },
      {
        "model": "tp",
        "scope": null,
        "trust": 0.2,
        "vendor": "simatic hmi panels",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "wincc runtime advanced",
        "version": "v11"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "wincc flexible runtime",
        "version": "*"
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "28691284-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2012-0460"
      },
      {
        "db": "BID",
        "id": "51835"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001312"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201202-085"
      },
      {
        "db": "NVD",
        "id": "CVE-2011-4510"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/a:siemens:simatic_hmi_panels",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/a:siemens:simatic_wincc_%28tia_portal%29",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/a:siemens:wincc_flexible",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/a:siemens:wincc_flexible_runtime",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/a:siemens:wincc_runtime_advanced",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001312"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Billy Rios, Terry McCorkle, Shawn Merdinger, and Luigi Auriemma.",
    "sources": [
      {
        "db": "BID",
        "id": "51835"
      }
    ],
    "trust": 0.3
  },
  "cve": "CVE-2011-4510",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "NONE",
            "baseScore": 4.3,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 8.6,
            "id": "CVE-2011-4510",
            "impactScore": 2.9,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 1.8,
            "vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N",
            "version": "2.0"
          },
          {
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "IVD",
            "availabilityImpact": "NONE",
            "baseScore": 4.3,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 8.6,
            "id": "28691284-2354-11e6-abef-000c29c66e3d",
            "impactScore": 2.9,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 0.2,
            "vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N",
            "version": "2.9 [IVD]"
          },
          {
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "NONE",
            "baseScore": 4.3,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 8.6,
            "id": "VHN-52455",
            "impactScore": 2.9,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 0.1,
            "vectorString": "AV:N/AC:M/AU:N/C:N/I:P/A:N",
            "version": "2.0"
          }
        ],
        "cvssV3": [],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2011-4510",
            "trust": 1.0,
            "value": "MEDIUM"
          },
          {
            "author": "NVD",
            "id": "CVE-2011-4510",
            "trust": 0.8,
            "value": "Medium"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201202-085",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "IVD",
            "id": "28691284-2354-11e6-abef-000c29c66e3d",
            "trust": 0.2,
            "value": "MEDIUM"
          },
          {
            "author": "VULHUB",
            "id": "VHN-52455",
            "trust": 0.1,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "28691284-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "VULHUB",
        "id": "VHN-52455"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001312"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201202-085"
      },
      {
        "db": "NVD",
        "id": "CVE-2011-4510"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Cross-site scripting (XSS) vulnerability in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allows remote attackers to inject arbitrary web script or HTML via unspecified vectors, a different vulnerability than CVE-2011-4511. plural Siemens Product HMI Web The server contains a cross-site scripting vulnerability. This vulnerability CVE-2011-4511 Is a different vulnerability.By any third party Web Script or HTML May be inserted. Siemens SIMATIC is an automation software in a single engineering environment. The SIMATIC HMI Smart Options web server has two separate cross-site scripting attacks that allow elevation of privilege, stealing data or corrupting services. SIMATIC HMI is prone to multiple unspecified cross-site scripting vulnerabilities because it fails to properly sanitize user-supplied input. \nAn attacker may leverage these issues to execute arbitrary script code in the browser of an unsuspecting user in the context of the affected site. This can allow the attacker to steal cookie-based authentication credentials and launch other attacks",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2011-4510"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001312"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2012-0460"
      },
      {
        "db": "BID",
        "id": "51835"
      },
      {
        "db": "IVD",
        "id": "28691284-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "VULHUB",
        "id": "VHN-52455"
      }
    ],
    "trust": 2.7
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2011-4510",
        "trust": 3.6
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-12-030-01",
        "trust": 3.4
      },
      {
        "db": "SIEMENS",
        "id": "SSA-345442",
        "trust": 1.7
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201202-085",
        "trust": 0.9
      },
      {
        "db": "CNVD",
        "id": "CNVD-2012-0460",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001312",
        "trust": 0.8
      },
      {
        "db": "NSFOCUS",
        "id": "19403",
        "trust": 0.6
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-12-030-01A",
        "trust": 0.3
      },
      {
        "db": "BID",
        "id": "51835",
        "trust": 0.3
      },
      {
        "db": "IVD",
        "id": "28691284-2354-11E6-ABEF-000C29C66E3D",
        "trust": 0.2
      },
      {
        "db": "VULHUB",
        "id": "VHN-52455",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "28691284-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2012-0460"
      },
      {
        "db": "VULHUB",
        "id": "VHN-52455"
      },
      {
        "db": "BID",
        "id": "51835"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001312"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201202-085"
      },
      {
        "db": "NVD",
        "id": "CVE-2011-4510"
      }
    ]
  },
  "id": "VAR-201202-0045",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "IVD",
        "id": "28691284-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2012-0460"
      },
      {
        "db": "VULHUB",
        "id": "VHN-52455"
      }
    ],
    "trust": 1.5239411500000002
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "28691284-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2012-0460"
      }
    ]
  },
  "last_update_date": "2025-04-11T22:49:48.241000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "SSA-345442",
        "trust": 0.8,
        "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf"
      },
      {
        "title": "\u30bd\u30ea\u30e5\u30fc\u30b7\u30e7\u30f3\u30d1\u30fc\u30c8\u30ca\u30fc",
        "trust": 0.8,
        "url": "http://www.automation.siemens.com/automation/jp/ja/solutionpartner/pages/default.aspx"
      },
      {
        "title": "Top Page",
        "trust": 0.8,
        "url": "http://www.siemens.com/entry/jp/ja/"
      },
      {
        "title": "Patch for Siemens SIMATIC WinCC HMI Cross-Site Scripting Vulnerability (CNVD-2012-0460)",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/9058"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2012-0460"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001312"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-79",
        "trust": 1.9
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-52455"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001312"
      },
      {
        "db": "NVD",
        "id": "CVE-2011-4510"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 3.4,
        "url": "http://www.us-cert.gov/control_systems/pdf/icsa-12-030-01.pdf"
      },
      {
        "trust": 1.7,
        "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf"
      },
      {
        "trust": 0.8,
        "url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2011-4510"
      },
      {
        "trust": 0.8,
        "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2011-4510"
      },
      {
        "trust": 0.6,
        "url": "http://www.nsfocus.net/vulndb/19403"
      },
      {
        "trust": 0.3,
        "url": "http://www.automation.siemens.com/mcms/automation/en/human-machine-interface/pages/default.aspx"
      },
      {
        "trust": 0.3,
        "url": "http://www.us-cert.gov/control_systems/pdf/icsa-12-030-01a.pdf"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2012-0460"
      },
      {
        "db": "VULHUB",
        "id": "VHN-52455"
      },
      {
        "db": "BID",
        "id": "51835"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001312"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201202-085"
      },
      {
        "db": "NVD",
        "id": "CVE-2011-4510"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "IVD",
        "id": "28691284-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2012-0460"
      },
      {
        "db": "VULHUB",
        "id": "VHN-52455"
      },
      {
        "db": "BID",
        "id": "51835"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001312"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201202-085"
      },
      {
        "db": "NVD",
        "id": "CVE-2011-4510"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2012-02-07T00:00:00",
        "db": "IVD",
        "id": "28691284-2354-11e6-abef-000c29c66e3d"
      },
      {
        "date": "2012-02-07T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2012-0460"
      },
      {
        "date": "2012-02-03T00:00:00",
        "db": "VULHUB",
        "id": "VHN-52455"
      },
      {
        "date": "2012-01-30T00:00:00",
        "db": "BID",
        "id": "51835"
      },
      {
        "date": "2012-02-08T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2012-001312"
      },
      {
        "date": "2012-02-07T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201202-085"
      },
      {
        "date": "2012-02-03T20:55:01.343000",
        "db": "NVD",
        "id": "CVE-2011-4510"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2012-02-07T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2012-0460"
      },
      {
        "date": "2012-02-06T00:00:00",
        "db": "VULHUB",
        "id": "VHN-52455"
      },
      {
        "date": "2012-04-18T21:20:00",
        "db": "BID",
        "id": "51835"
      },
      {
        "date": "2012-02-08T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2012-001312"
      },
      {
        "date": "2012-02-07T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201202-085"
      },
      {
        "date": "2025-04-11T00:51:21.963000",
        "db": "NVD",
        "id": "CVE-2011-4510"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201202-085"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "plural  Siemens Product  HMI Web Server cross-site scripting vulnerability",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001312"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "XSS",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201202-085"
      }
    ],
    "trust": 0.6
  }
}

VAR-201202-0049

Vulnerability from variot - Updated: 2025-04-11 22:49

The TELNET daemon in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime does not perform authentication, which makes it easier for remote attackers to obtain access via a TCP session. plural Siemens Product TELNET Since the daemon does not authenticate, there is a vulnerability that allows easy access.By a third party TCP Access can easily be gained through a session. Siemens SIMATIC is an automation software in a single engineering environment. SIMATIC panels include the Telnet daemon by default, but the daemon does not implement any validation features. A vulnerability exists in several versions of Siemens SIMATIC WinCC due to the failure of the TELNET daemon to perform authentication. A remote attacker could use this vulnerability to gain access through a TCP session

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201202-0049",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "simatic hmi panels",
        "scope": "eq",
        "trust": 2.4,
        "vendor": "siemens",
        "version": "mp"
      },
      {
        "model": "simatic hmi panels",
        "scope": "eq",
        "trust": 2.4,
        "vendor": "siemens",
        "version": "op"
      },
      {
        "model": "simatic hmi panels",
        "scope": "eq",
        "trust": 2.4,
        "vendor": "siemens",
        "version": "tp"
      },
      {
        "model": "wincc flexible",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "2008"
      },
      {
        "model": "simatic hmi panels",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "comfort_panels"
      },
      {
        "model": "wincc runtime advanced",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "v11"
      },
      {
        "model": "wincc",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "v11"
      },
      {
        "model": "simatic hmi panels",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "mobile_panels"
      },
      {
        "model": "wincc flexible",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "2007"
      },
      {
        "model": "simatic wincc flexible",
        "scope": "eq",
        "trust": 1.4,
        "vendor": "siemens",
        "version": "2008"
      },
      {
        "model": "simatic wincc flexible",
        "scope": "eq",
        "trust": 1.4,
        "vendor": "siemens",
        "version": "2007"
      },
      {
        "model": "simatic wincc flexible",
        "scope": "eq",
        "trust": 1.4,
        "vendor": "siemens",
        "version": "2005"
      },
      {
        "model": "simatic wincc flexible",
        "scope": "eq",
        "trust": 1.4,
        "vendor": "siemens",
        "version": "2004"
      },
      {
        "model": "simatic wincc",
        "scope": "eq",
        "trust": 1.4,
        "vendor": "siemens",
        "version": "v11"
      },
      {
        "model": "wincc flexible",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2004"
      },
      {
        "model": "wincc flexible runtime",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "wincc flexible",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2005"
      },
      {
        "model": "simatic hmi panels",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "siemens",
        "version": "comfort panels"
      },
      {
        "model": "simatic hmi panels",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "siemens",
        "version": "mobile panels"
      },
      {
        "model": "simatic wincc flexible rumtime",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic wincc runtime advanced",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "siemens",
        "version": "v11"
      },
      {
        "model": "simatic wincc flexible runtime",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic wincc runtime advanced",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic hmi panels",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic wincc",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "wincc flexible runtime",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "wincc flexible",
        "version": "2004"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "wincc flexible",
        "version": "2005"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "wincc flexible",
        "version": "2007"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "wincc flexible",
        "version": "2008"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "wincc",
        "version": "v11"
      },
      {
        "model": "comfort panels",
        "scope": null,
        "trust": 0.2,
        "vendor": "simatic hmi panels",
        "version": null
      },
      {
        "model": "mobile panels",
        "scope": null,
        "trust": 0.2,
        "vendor": "simatic hmi panels",
        "version": null
      },
      {
        "model": "mp",
        "scope": null,
        "trust": 0.2,
        "vendor": "simatic hmi panels",
        "version": null
      },
      {
        "model": "op",
        "scope": null,
        "trust": 0.2,
        "vendor": "simatic hmi panels",
        "version": null
      },
      {
        "model": "tp",
        "scope": null,
        "trust": 0.2,
        "vendor": "simatic hmi panels",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "wincc runtime advanced",
        "version": "v11"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "wincc flexible runtime",
        "version": "*"
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "28d0ca64-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2012-0464"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001316"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201202-089"
      },
      {
        "db": "NVD",
        "id": "CVE-2011-4514"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/a:siemens:simatic_hmi_panels",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/a:siemens:simatic_wincc_%28tia_portal%29",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/a:siemens:wincc_flexible",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/a:siemens:wincc_flexible_runtime",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/a:siemens:wincc_runtime_advanced",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001316"
      }
    ]
  },
  "cve": "CVE-2011-4514",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "CVE-2011-4514",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 1.8,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "IVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "28d0ca64-2354-11e6-abef-000c29c66e3d",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.2,
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.9 [IVD]"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10.0,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 10.0,
            "id": "VHN-52459",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.1,
            "vectorString": "AV:N/AC:L/AU:N/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2011-4514",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "NVD",
            "id": "CVE-2011-4514",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201202-089",
            "trust": 0.6,
            "value": "CRITICAL"
          },
          {
            "author": "IVD",
            "id": "28d0ca64-2354-11e6-abef-000c29c66e3d",
            "trust": 0.2,
            "value": "CRITICAL"
          },
          {
            "author": "VULHUB",
            "id": "VHN-52459",
            "trust": 0.1,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "28d0ca64-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "VULHUB",
        "id": "VHN-52459"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001316"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201202-089"
      },
      {
        "db": "NVD",
        "id": "CVE-2011-4514"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "The TELNET daemon in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime does not perform authentication, which makes it easier for remote attackers to obtain access via a TCP session. plural Siemens Product TELNET Since the daemon does not authenticate, there is a vulnerability that allows easy access.By a third party TCP Access can easily be gained through a session. Siemens SIMATIC is an automation software in a single engineering environment. SIMATIC panels include the Telnet daemon by default, but the daemon does not implement any validation features. A vulnerability exists in several versions of Siemens SIMATIC WinCC due to the failure of the TELNET daemon to perform authentication. A remote attacker could use this vulnerability to gain access through a TCP session",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2011-4514"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001316"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2012-0464"
      },
      {
        "db": "IVD",
        "id": "28d0ca64-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "VULHUB",
        "id": "VHN-52459"
      }
    ],
    "trust": 2.43
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2011-4514",
        "trust": 3.3
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-12-030-01",
        "trust": 3.1
      },
      {
        "db": "SIEMENS",
        "id": "SSA-345442",
        "trust": 1.7
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201202-089",
        "trust": 0.9
      },
      {
        "db": "CNVD",
        "id": "CNVD-2012-0464",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001316",
        "trust": 0.8
      },
      {
        "db": "IVD",
        "id": "28D0CA64-2354-11E6-ABEF-000C29C66E3D",
        "trust": 0.2
      },
      {
        "db": "VULHUB",
        "id": "VHN-52459",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "28d0ca64-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2012-0464"
      },
      {
        "db": "VULHUB",
        "id": "VHN-52459"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001316"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201202-089"
      },
      {
        "db": "NVD",
        "id": "CVE-2011-4514"
      }
    ]
  },
  "id": "VAR-201202-0049",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "IVD",
        "id": "28d0ca64-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2012-0464"
      },
      {
        "db": "VULHUB",
        "id": "VHN-52459"
      }
    ],
    "trust": 1.5153960400000002
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "28d0ca64-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2012-0464"
      }
    ]
  },
  "last_update_date": "2025-04-11T22:49:48.205000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "SSA-345442",
        "trust": 0.8,
        "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf"
      },
      {
        "title": "\u30bd\u30ea\u30e5\u30fc\u30b7\u30e7\u30f3\u30d1\u30fc\u30c8\u30ca\u30fc",
        "trust": 0.8,
        "url": "http://www.automation.siemens.com/automation/jp/ja/solutionpartner/pages/default.aspx"
      },
      {
        "title": "Top Page",
        "trust": 0.8,
        "url": "http://www.siemens.com/entry/jp/ja/"
      },
      {
        "title": "Patch for Siemens SIMATIC WinCC HMI Telnet Vulnerability (CNVD-2012-0464)",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/9062"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2012-0464"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001316"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-287",
        "trust": 1.9
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-52459"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001316"
      },
      {
        "db": "NVD",
        "id": "CVE-2011-4514"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 3.1,
        "url": "http://www.us-cert.gov/control_systems/pdf/icsa-12-030-01.pdf"
      },
      {
        "trust": 1.7,
        "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf"
      },
      {
        "trust": 0.8,
        "url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2011-4514"
      },
      {
        "trust": 0.8,
        "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2011-4514"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2012-0464"
      },
      {
        "db": "VULHUB",
        "id": "VHN-52459"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001316"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201202-089"
      },
      {
        "db": "NVD",
        "id": "CVE-2011-4514"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "IVD",
        "id": "28d0ca64-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2012-0464"
      },
      {
        "db": "VULHUB",
        "id": "VHN-52459"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001316"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201202-089"
      },
      {
        "db": "NVD",
        "id": "CVE-2011-4514"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2012-02-07T00:00:00",
        "db": "IVD",
        "id": "28d0ca64-2354-11e6-abef-000c29c66e3d"
      },
      {
        "date": "2012-02-07T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2012-0464"
      },
      {
        "date": "2012-02-03T00:00:00",
        "db": "VULHUB",
        "id": "VHN-52459"
      },
      {
        "date": "2012-02-08T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2012-001316"
      },
      {
        "date": "2012-02-07T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201202-089"
      },
      {
        "date": "2012-02-03T20:55:01.577000",
        "db": "NVD",
        "id": "CVE-2011-4514"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2012-02-07T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2012-0464"
      },
      {
        "date": "2012-02-06T00:00:00",
        "db": "VULHUB",
        "id": "VHN-52459"
      },
      {
        "date": "2012-02-08T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2012-001316"
      },
      {
        "date": "2012-02-07T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201202-089"
      },
      {
        "date": "2025-04-11T00:51:21.963000",
        "db": "NVD",
        "id": "CVE-2011-4514"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201202-089"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "plural  Siemens Product  TELNET Access vulnerability in daemon",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001316"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "authorization issue",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201202-089"
      }
    ],
    "trust": 0.6
  }
}

VAR-201202-0047

Vulnerability from variot - Updated: 2025-04-11 22:49

CRLF injection vulnerability in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allows remote attackers to inject arbitrary HTTP headers and conduct HTTP response splitting attacks via unspecified vectors. plural Siemens Product HMI Web The server CRLF An injection vulnerability exists.By any third party HTTP Inserted header, and HTTP Response splitting attacks can be triggered. Siemens SIMATIC is an automation software in a single engineering environment. The HMI web server has a header injection vulnerability that allows elevation of privilege, stealing data or breaking services. Siemens SIMATIC WinCC is prone to an HTTP-header-injection issue, a directory-traversal issue, and an arbitrary memory-read access issue because the application fails to properly sanitize user-supplied input. A remote attacker can exploit these issues to gain elevated privileges, obtain sensitive information, or cause denial-of-service conditions

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201202-0047",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "simatic hmi panels",
        "scope": "eq",
        "trust": 2.4,
        "vendor": "siemens",
        "version": "mp"
      },
      {
        "model": "simatic hmi panels",
        "scope": "eq",
        "trust": 2.4,
        "vendor": "siemens",
        "version": "op"
      },
      {
        "model": "simatic hmi panels",
        "scope": "eq",
        "trust": 2.4,
        "vendor": "siemens",
        "version": "tp"
      },
      {
        "model": "simatic wincc flexible",
        "scope": "eq",
        "trust": 1.7,
        "vendor": "siemens",
        "version": "2007"
      },
      {
        "model": "simatic wincc flexible",
        "scope": "eq",
        "trust": 1.7,
        "vendor": "siemens",
        "version": "2005"
      },
      {
        "model": "simatic wincc flexible",
        "scope": "eq",
        "trust": 1.7,
        "vendor": "siemens",
        "version": "2004"
      },
      {
        "model": "simatic hmi panels",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "comfort_panels"
      },
      {
        "model": "wincc runtime advanced",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "v11"
      },
      {
        "model": "wincc",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "v11"
      },
      {
        "model": "simatic hmi panels",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "mobile_panels"
      },
      {
        "model": "wincc flexible",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2004"
      },
      {
        "model": "wincc flexible runtime",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "wincc flexible",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2007"
      },
      {
        "model": "wincc",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "v11"
      },
      {
        "model": "wincc flexible",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2005"
      },
      {
        "model": "wincc flexible",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2008"
      },
      {
        "model": "simatic wincc flexible",
        "scope": "eq",
        "trust": 0.9,
        "vendor": "siemens",
        "version": "2008"
      },
      {
        "model": "simatic wincc",
        "scope": "eq",
        "trust": 0.9,
        "vendor": "siemens",
        "version": "v11"
      },
      {
        "model": "simatic hmi panels",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "siemens",
        "version": "comfort panels"
      },
      {
        "model": "simatic hmi panels",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "siemens",
        "version": "mobile panels"
      },
      {
        "model": "simatic wincc",
        "scope": "lt",
        "trust": 0.8,
        "vendor": "siemens",
        "version": "v11 sp2 update 1"
      },
      {
        "model": "simatic wincc flexible",
        "scope": "lt",
        "trust": 0.8,
        "vendor": "siemens",
        "version": "2008 sp3"
      },
      {
        "model": "simatic wincc flexible rumtime",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic wincc runtime advanced",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "siemens",
        "version": "v11"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.6,
        "vendor": "wincc flexible",
        "version": "2008"
      },
      {
        "model": "simatic wincc flexible runtime",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic wincc runtime advanced",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic hmi panels",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic wincc",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "wincc flexible runtime",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.4,
        "vendor": "wincc",
        "version": "v11"
      },
      {
        "model": "simatic wincc flexible runtime",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic wincc runtime advanced",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic wincc",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic hmi panels",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "wincc flexible",
        "version": "2004"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "wincc flexible",
        "version": "2005"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "wincc flexible",
        "version": "2007"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "wincc",
        "version": "*"
      },
      {
        "model": "comfort panels",
        "scope": null,
        "trust": 0.2,
        "vendor": "simatic hmi panels",
        "version": null
      },
      {
        "model": "mobile panels",
        "scope": null,
        "trust": 0.2,
        "vendor": "simatic hmi panels",
        "version": null
      },
      {
        "model": "mp",
        "scope": null,
        "trust": 0.2,
        "vendor": "simatic hmi panels",
        "version": null
      },
      {
        "model": "op",
        "scope": null,
        "trust": 0.2,
        "vendor": "simatic hmi panels",
        "version": null
      },
      {
        "model": "tp",
        "scope": null,
        "trust": 0.2,
        "vendor": "simatic hmi panels",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "wincc runtime advanced",
        "version": "v11"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "wincc flexible runtime",
        "version": "*"
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "289d30d2-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2012-0462"
      },
      {
        "db": "BID",
        "id": "51836"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001314"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201202-087"
      },
      {
        "db": "NVD",
        "id": "CVE-2011-4512"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/a:siemens:simatic_hmi_panels",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/a:siemens:simatic_wincc_%28tia_portal%29",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/a:siemens:wincc_flexible",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/a:siemens:wincc_flexible_runtime",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/a:siemens:wincc_runtime_advanced",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001314"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "ICS-CERT",
    "sources": [
      {
        "db": "BID",
        "id": "51836"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201202-087"
      }
    ],
    "trust": 0.9
  },
  "cve": "CVE-2011-4512",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "NONE",
            "baseScore": 5.0,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "CVE-2011-4512",
            "impactScore": 2.9,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 1.8,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:N",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "IVD",
            "availabilityImpact": "NONE",
            "baseScore": 5.0,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "289d30d2-2354-11e6-abef-000c29c66e3d",
            "impactScore": 2.9,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 0.2,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:N",
            "version": "2.9 [IVD]"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "NONE",
            "baseScore": 5.0,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "VHN-52457",
            "impactScore": 2.9,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 0.1,
            "vectorString": "AV:N/AC:L/AU:N/C:N/I:P/A:N",
            "version": "2.0"
          }
        ],
        "cvssV3": [],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2011-4512",
            "trust": 1.0,
            "value": "MEDIUM"
          },
          {
            "author": "NVD",
            "id": "CVE-2011-4512",
            "trust": 0.8,
            "value": "Medium"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201202-087",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "IVD",
            "id": "289d30d2-2354-11e6-abef-000c29c66e3d",
            "trust": 0.2,
            "value": "MEDIUM"
          },
          {
            "author": "VULHUB",
            "id": "VHN-52457",
            "trust": 0.1,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "289d30d2-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "VULHUB",
        "id": "VHN-52457"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001314"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201202-087"
      },
      {
        "db": "NVD",
        "id": "CVE-2011-4512"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "CRLF injection vulnerability in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allows remote attackers to inject arbitrary HTTP headers and conduct HTTP response splitting attacks via unspecified vectors. plural Siemens Product HMI Web The server CRLF An injection vulnerability exists.By any third party HTTP Inserted header, and HTTP Response splitting attacks can be triggered. Siemens SIMATIC is an automation software in a single engineering environment. The HMI web server has a header injection vulnerability that allows elevation of privilege, stealing data or breaking services. Siemens SIMATIC WinCC is prone to an HTTP-header-injection issue, a directory-traversal issue, and an arbitrary memory-read access issue because the application fails to properly sanitize user-supplied input. \nA remote attacker can exploit these issues to gain elevated privileges, obtain sensitive information, or cause denial-of-service conditions",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2011-4512"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001314"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2012-0462"
      },
      {
        "db": "BID",
        "id": "51836"
      },
      {
        "db": "IVD",
        "id": "289d30d2-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "VULHUB",
        "id": "VHN-52457"
      }
    ],
    "trust": 2.7
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2011-4512",
        "trust": 3.6
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-12-030-01",
        "trust": 3.4
      },
      {
        "db": "SIEMENS",
        "id": "SSA-345442",
        "trust": 1.7
      },
      {
        "db": "CNVD",
        "id": "CNVD-2012-0462",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201202-087",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001314",
        "trust": 0.8
      },
      {
        "db": "NSFOCUS",
        "id": "18633",
        "trust": 0.6
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-12-030-01A",
        "trust": 0.3
      },
      {
        "db": "BID",
        "id": "51836",
        "trust": 0.3
      },
      {
        "db": "IVD",
        "id": "289D30D2-2354-11E6-ABEF-000C29C66E3D",
        "trust": 0.2
      },
      {
        "db": "VULHUB",
        "id": "VHN-52457",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "289d30d2-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2012-0462"
      },
      {
        "db": "VULHUB",
        "id": "VHN-52457"
      },
      {
        "db": "BID",
        "id": "51836"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001314"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201202-087"
      },
      {
        "db": "NVD",
        "id": "CVE-2011-4512"
      }
    ]
  },
  "id": "VAR-201202-0047",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "IVD",
        "id": "289d30d2-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2012-0462"
      },
      {
        "db": "VULHUB",
        "id": "VHN-52457"
      }
    ],
    "trust": 1.5153960400000002
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "289d30d2-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2012-0462"
      }
    ]
  },
  "last_update_date": "2025-04-11T22:49:48.163000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "SSA-345442",
        "trust": 0.8,
        "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf"
      },
      {
        "title": "\u30bd\u30ea\u30e5\u30fc\u30b7\u30e7\u30f3\u30d1\u30fc\u30c8\u30ca\u30fc",
        "trust": 0.8,
        "url": "http://www.automation.siemens.com/automation/jp/ja/solutionpartner/pages/default.aspx"
      },
      {
        "title": "Top Page",
        "trust": 0.8,
        "url": "http://www.siemens.com/entry/jp/ja/"
      },
      {
        "title": "Patch for Siemens SIMATIC WinCC HMI Header Injection Vulnerability (CNVD-2012-0462)",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/9060"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2012-0462"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001314"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-94",
        "trust": 1.9
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-52457"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001314"
      },
      {
        "db": "NVD",
        "id": "CVE-2011-4512"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 3.4,
        "url": "http://www.us-cert.gov/control_systems/pdf/icsa-12-030-01.pdf"
      },
      {
        "trust": 1.7,
        "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf"
      },
      {
        "trust": 0.8,
        "url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2011-4512"
      },
      {
        "trust": 0.8,
        "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2011-4512"
      },
      {
        "trust": 0.6,
        "url": "http://www.nsfocus.net/vulndb/18633"
      },
      {
        "trust": 0.3,
        "url": "http://www.automation.siemens.com/mcms/human-machine-interface/en/visualization-software/scada/pages/default.aspx"
      },
      {
        "trust": 0.3,
        "url": "http://www.us-cert.gov/control_systems/pdf/icsa-12-030-01a.pdf"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2012-0462"
      },
      {
        "db": "VULHUB",
        "id": "VHN-52457"
      },
      {
        "db": "BID",
        "id": "51836"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001314"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201202-087"
      },
      {
        "db": "NVD",
        "id": "CVE-2011-4512"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "IVD",
        "id": "289d30d2-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2012-0462"
      },
      {
        "db": "VULHUB",
        "id": "VHN-52457"
      },
      {
        "db": "BID",
        "id": "51836"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001314"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201202-087"
      },
      {
        "db": "NVD",
        "id": "CVE-2011-4512"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2012-02-07T00:00:00",
        "db": "IVD",
        "id": "289d30d2-2354-11e6-abef-000c29c66e3d"
      },
      {
        "date": "2012-02-07T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2012-0462"
      },
      {
        "date": "2012-02-03T00:00:00",
        "db": "VULHUB",
        "id": "VHN-52457"
      },
      {
        "date": "2012-02-02T00:00:00",
        "db": "BID",
        "id": "51836"
      },
      {
        "date": "2012-02-08T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2012-001314"
      },
      {
        "date": "2012-02-07T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201202-087"
      },
      {
        "date": "2012-02-03T20:55:01.453000",
        "db": "NVD",
        "id": "CVE-2011-4512"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2012-02-07T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2012-0462"
      },
      {
        "date": "2012-02-06T00:00:00",
        "db": "VULHUB",
        "id": "VHN-52457"
      },
      {
        "date": "2012-04-18T21:20:00",
        "db": "BID",
        "id": "51836"
      },
      {
        "date": "2012-02-08T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2012-001314"
      },
      {
        "date": "2012-02-07T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201202-087"
      },
      {
        "date": "2025-04-11T00:51:21.963000",
        "db": "NVD",
        "id": "CVE-2011-4512"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201202-087"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Siemens SIMATIC WinCC HMI Web Server Multiple Input Validation Vulnerabilities",
    "sources": [
      {
        "db": "BID",
        "id": "51836"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201202-087"
      }
    ],
    "trust": 0.9
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Code injection",
    "sources": [
      {
        "db": "IVD",
        "id": "289d30d2-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201202-087"
      }
    ],
    "trust": 0.8
  }
}

VAR-201202-0166

Vulnerability from variot - Updated: 2025-04-11 22:49

miniweb.exe in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime does not properly handle URIs beginning with a 0xfa character, which allows remote attackers to read data from arbitrary memory locations or cause a denial of service (application crash) via a crafted POST request. Siemens SIMATIC is an automation software in a single engineering environment. A security vulnerability exists in the Siemens SIMATIC WinCC HMI web server. The HMI web server does not properly validate the HTTP request. The first byte in the URL is manipulated. Siemens SIMATIC WinCC is prone to an HTTP-header-injection issue, a directory-traversal issue, and an arbitrary memory-read access issue because the application fails to properly sanitize user-supplied input. A remote attacker can exploit these issues to gain elevated privileges, obtain sensitive information, or cause denial-of-service conditions. The vulnerability stems from the failure of miniweb.exe in the HMI web server to correctly handle URLs starting with the 0xfa character

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201202-0166",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "simatic hmi panels",
        "scope": "eq",
        "trust": 2.4,
        "vendor": "siemens",
        "version": "mp"
      },
      {
        "model": "simatic hmi panels",
        "scope": "eq",
        "trust": 2.4,
        "vendor": "siemens",
        "version": "tp"
      },
      {
        "model": "simatic hmi panels",
        "scope": "eq",
        "trust": 2.4,
        "vendor": "siemens",
        "version": "op"
      },
      {
        "model": "simatic wincc flexible",
        "scope": "eq",
        "trust": 1.7,
        "vendor": "siemens",
        "version": "2007"
      },
      {
        "model": "simatic wincc flexible",
        "scope": "eq",
        "trust": 1.7,
        "vendor": "siemens",
        "version": "2005"
      },
      {
        "model": "simatic wincc flexible",
        "scope": "eq",
        "trust": 1.7,
        "vendor": "siemens",
        "version": "2004"
      },
      {
        "model": "simatic hmi panels",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "comfort_panels"
      },
      {
        "model": "wincc runtime advanced",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "v11"
      },
      {
        "model": "wincc",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "v11"
      },
      {
        "model": "simatic hmi panels",
        "scope": "eq",
        "trust": 1.6,
        "vendor": "siemens",
        "version": "mobile_panels"
      },
      {
        "model": "wincc flexible",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2004"
      },
      {
        "model": "wincc flexible runtime",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "wincc flexible",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2007"
      },
      {
        "model": "wincc",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "v11"
      },
      {
        "model": "wincc flexible",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2005"
      },
      {
        "model": "wincc flexible",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2008"
      },
      {
        "model": "simatic wincc flexible",
        "scope": "eq",
        "trust": 0.9,
        "vendor": "siemens",
        "version": "2008"
      },
      {
        "model": "simatic wincc",
        "scope": "eq",
        "trust": 0.9,
        "vendor": "siemens",
        "version": "v11"
      },
      {
        "model": "simatic wincc",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "siemens",
        "version": "sp2 update 1"
      },
      {
        "model": "simatic wincc",
        "scope": "lt",
        "trust": 0.8,
        "vendor": "siemens",
        "version": "v11\\\\"
      },
      {
        "model": "simatic hmi panels",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "siemens",
        "version": "comfort panels"
      },
      {
        "model": "simatic wincc runtime advanced",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "siemens",
        "version": "v11"
      },
      {
        "model": "simatic hmi panels",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "siemens",
        "version": "mobile panels"
      },
      {
        "model": "simatic wincc flexible rumtime",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.6,
        "vendor": "wincc flexible",
        "version": "2008"
      },
      {
        "model": "simatic wincc flexible runtime",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic wincc runtime advanced",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic hmi panels",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic wincc",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "wincc flexible runtime",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.4,
        "vendor": "wincc",
        "version": "v11"
      },
      {
        "model": "simatic wincc flexible runtime",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic wincc runtime advanced",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic wincc",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic hmi panels",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "wincc flexible",
        "version": "2004"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "wincc flexible",
        "version": "2005"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "wincc flexible",
        "version": "2007"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "wincc",
        "version": "*"
      },
      {
        "model": "comfort panels",
        "scope": null,
        "trust": 0.2,
        "vendor": "simatic hmi panels",
        "version": null
      },
      {
        "model": "mobile panels",
        "scope": null,
        "trust": 0.2,
        "vendor": "simatic hmi panels",
        "version": null
      },
      {
        "model": "mp",
        "scope": null,
        "trust": 0.2,
        "vendor": "simatic hmi panels",
        "version": null
      },
      {
        "model": "op",
        "scope": null,
        "trust": 0.2,
        "vendor": "simatic hmi panels",
        "version": null
      },
      {
        "model": "tp",
        "scope": null,
        "trust": 0.2,
        "vendor": "simatic hmi panels",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "wincc runtime advanced",
        "version": "v11"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "wincc flexible runtime",
        "version": "*"
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "28903b3e-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2012-0469"
      },
      {
        "db": "BID",
        "id": "51836"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001321"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201202-094"
      },
      {
        "db": "NVD",
        "id": "CVE-2011-4879"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/a:siemens:simatic_hmi_panels",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/a:siemens:simatic_wincc_%28tia_portal%29",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/a:siemens:wincc_flexible",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/a:siemens:wincc_flexible_runtime",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/a:siemens:wincc_runtime_advanced",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001321"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "ICS-CERT",
    "sources": [
      {
        "db": "BID",
        "id": "51836"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201202-094"
      }
    ],
    "trust": 0.9
  },
  "cve": "CVE-2011-4879",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "COMPLETE",
            "baseScore": 8.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CVE-2011-4879",
            "impactScore": 7.8,
            "integrityImpact": "NONE",
            "severity": "HIGH",
            "trust": 1.8,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "IVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 8.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "28903b3e-2354-11e6-abef-000c29c66e3d",
            "impactScore": 7.8,
            "integrityImpact": "NONE",
            "severity": "HIGH",
            "trust": 0.2,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:C",
            "version": "2.9 [IVD]"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "COMPLETE",
            "baseScore": 8.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "VHN-52824",
            "impactScore": 7.8,
            "integrityImpact": "NONE",
            "severity": "HIGH",
            "trust": 0.1,
            "vectorString": "AV:N/AC:L/AU:N/C:P/I:N/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2011-4879",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "NVD",
            "id": "CVE-2011-4879",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201202-094",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "IVD",
            "id": "28903b3e-2354-11e6-abef-000c29c66e3d",
            "trust": 0.2,
            "value": "HIGH"
          },
          {
            "author": "VULHUB",
            "id": "VHN-52824",
            "trust": 0.1,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "28903b3e-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "VULHUB",
        "id": "VHN-52824"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001321"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201202-094"
      },
      {
        "db": "NVD",
        "id": "CVE-2011-4879"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "miniweb.exe in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime does not properly handle URIs beginning with a 0xfa character, which allows remote attackers to read data from arbitrary memory locations or cause a denial of service (application crash) via a crafted POST request. Siemens SIMATIC is an automation software in a single engineering environment. A security vulnerability exists in the Siemens SIMATIC WinCC HMI web server. The HMI web server does not properly validate the HTTP request. The first byte in the URL is manipulated. Siemens SIMATIC WinCC is prone to an HTTP-header-injection issue, a directory-traversal issue, and an arbitrary memory-read access issue because the application fails to properly sanitize user-supplied input. \nA remote attacker can exploit these issues to gain elevated privileges, obtain sensitive information, or cause denial-of-service conditions. The vulnerability stems from the failure of miniweb.exe in the HMI web server to correctly handle URLs starting with the 0xfa character",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2011-4879"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001321"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2012-0469"
      },
      {
        "db": "BID",
        "id": "51836"
      },
      {
        "db": "IVD",
        "id": "28903b3e-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "VULHUB",
        "id": "VHN-52824"
      }
    ],
    "trust": 2.7
  },
  "exploit_availability": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/exploit_availability#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "reference": "https://www.scap.org.cn/vuln/vhn-52824",
        "trust": 0.1,
        "type": "unknown"
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-52824"
      }
    ]
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2011-4879",
        "trust": 3.6
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-12-030-01",
        "trust": 3.4
      },
      {
        "db": "SIEMENS",
        "id": "SSA-345442",
        "trust": 1.7
      },
      {
        "db": "ICS CERT ALERT",
        "id": "ICS-ALERT-11-332-02A",
        "trust": 1.1
      },
      {
        "db": "ICS CERT ALERT",
        "id": "ICS-ALERT-11-332-02",
        "trust": 1.1
      },
      {
        "db": "OSVDB",
        "id": "77384",
        "trust": 1.1
      },
      {
        "db": "EXPLOIT-DB",
        "id": "18166",
        "trust": 1.1
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201202-094",
        "trust": 0.9
      },
      {
        "db": "CNVD",
        "id": "CNVD-2012-0469",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001321",
        "trust": 0.8
      },
      {
        "db": "NSFOCUS",
        "id": "18633",
        "trust": 0.6
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-12-030-01A",
        "trust": 0.3
      },
      {
        "db": "BID",
        "id": "51836",
        "trust": 0.3
      },
      {
        "db": "IVD",
        "id": "28903B3E-2354-11E6-ABEF-000C29C66E3D",
        "trust": 0.2
      },
      {
        "db": "VULHUB",
        "id": "VHN-52824",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "28903b3e-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2012-0469"
      },
      {
        "db": "VULHUB",
        "id": "VHN-52824"
      },
      {
        "db": "BID",
        "id": "51836"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001321"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201202-094"
      },
      {
        "db": "NVD",
        "id": "CVE-2011-4879"
      }
    ]
  },
  "id": "VAR-201202-0166",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "IVD",
        "id": "28903b3e-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2012-0469"
      },
      {
        "db": "VULHUB",
        "id": "VHN-52824"
      }
    ],
    "trust": 1.5153960400000002
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "28903b3e-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2012-0469"
      }
    ]
  },
  "last_update_date": "2025-04-11T22:49:48.122000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "SSA-345442",
        "trust": 0.8,
        "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf"
      },
      {
        "title": "\u30bd\u30ea\u30e5\u30fc\u30b7\u30e7\u30f3\u30d1\u30fc\u30c8\u30ca\u30fc",
        "trust": 0.8,
        "url": "http://www.automation.siemens.com/automation/jp/ja/solutionpartner/pages/default.aspx"
      },
      {
        "title": "Top Page",
        "trust": 0.8,
        "url": "http://www.siemens.com/entry/jp/ja/"
      },
      {
        "title": "Patch for Siemens SIMATIC WinCC HMI Vulnerability (CNVD-2012-0469)",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/9075"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2012-0469"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001321"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-20",
        "trust": 1.9
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-52824"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001321"
      },
      {
        "db": "NVD",
        "id": "CVE-2011-4879"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 3.4,
        "url": "http://www.us-cert.gov/control_systems/pdf/icsa-12-030-01.pdf"
      },
      {
        "trust": 1.7,
        "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf"
      },
      {
        "trust": 1.1,
        "url": "http://www.exploit-db.com/exploits/18166"
      },
      {
        "trust": 1.1,
        "url": "http://aluigi.org/adv/winccflex_1-adv.txt"
      },
      {
        "trust": 1.1,
        "url": "http://www.us-cert.gov/control_systems/pdf/ics-alert-11-332-02.pdf"
      },
      {
        "trust": 1.1,
        "url": "http://www.us-cert.gov/control_systems/pdf/ics-alert-11-332-02a.pdf"
      },
      {
        "trust": 1.1,
        "url": "http://www.osvdb.org/77384"
      },
      {
        "trust": 1.1,
        "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/71453"
      },
      {
        "trust": 0.8,
        "url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2011-4879"
      },
      {
        "trust": 0.8,
        "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2011-4879"
      },
      {
        "trust": 0.6,
        "url": "http://aluigi.altervista.org/adv/winccflex_1-adv.txt"
      },
      {
        "trust": 0.6,
        "url": "http://www.nsfocus.net/vulndb/18633"
      },
      {
        "trust": 0.3,
        "url": "http://www.automation.siemens.com/mcms/human-machine-interface/en/visualization-software/scada/pages/default.aspx"
      },
      {
        "trust": 0.3,
        "url": "http://www.us-cert.gov/control_systems/pdf/icsa-12-030-01a.pdf"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2012-0469"
      },
      {
        "db": "VULHUB",
        "id": "VHN-52824"
      },
      {
        "db": "BID",
        "id": "51836"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001321"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201202-094"
      },
      {
        "db": "NVD",
        "id": "CVE-2011-4879"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "IVD",
        "id": "28903b3e-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2012-0469"
      },
      {
        "db": "VULHUB",
        "id": "VHN-52824"
      },
      {
        "db": "BID",
        "id": "51836"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001321"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201202-094"
      },
      {
        "db": "NVD",
        "id": "CVE-2011-4879"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2012-02-07T00:00:00",
        "db": "IVD",
        "id": "28903b3e-2354-11e6-abef-000c29c66e3d"
      },
      {
        "date": "2012-02-07T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2012-0469"
      },
      {
        "date": "2012-02-03T00:00:00",
        "db": "VULHUB",
        "id": "VHN-52824"
      },
      {
        "date": "2012-02-02T00:00:00",
        "db": "BID",
        "id": "51836"
      },
      {
        "date": "2012-02-08T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2012-001321"
      },
      {
        "date": "2012-02-07T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201202-094"
      },
      {
        "date": "2012-02-03T20:55:02.077000",
        "db": "NVD",
        "id": "CVE-2011-4879"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2012-02-07T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2012-0469"
      },
      {
        "date": "2017-08-29T00:00:00",
        "db": "VULHUB",
        "id": "VHN-52824"
      },
      {
        "date": "2012-04-18T21:20:00",
        "db": "BID",
        "id": "51836"
      },
      {
        "date": "2012-02-08T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2012-001321"
      },
      {
        "date": "2012-02-07T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201202-094"
      },
      {
        "date": "2025-04-11T00:51:21.963000",
        "db": "NVD",
        "id": "CVE-2011-4879"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201202-094"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "plural  Siemens Product  HMI Web Vulnerability to read data from arbitrary memory locations on the server",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2012-001321"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Input validation",
    "sources": [
      {
        "db": "IVD",
        "id": "28903b3e-2354-11e6-abef-000c29c66e3d"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201202-094"
      }
    ],
    "trust": 0.8
  }
}

VAR-202405-0210

Vulnerability from variot - Updated: 2024-12-10 21:17

A vulnerability has been identified in Security Configuration Tool (SCT) (All versions), SIMATIC Automation Tool (All versions < V5.0 SP2), SIMATIC BATCH V9.1 (All versions < V9.1 SP2 Upd5), SIMATIC NET PC Software V16 (All versions < V16 Update 8), SIMATIC NET PC Software V17 (All versions), SIMATIC NET PC Software V18 (All versions < V18 SP1), SIMATIC NET PC Software V19 (All versions < V19 Update 2), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP2 UC05), SIMATIC PDM V9.2 (All versions < V9.2 SP2 Upd3), SIMATIC Route Control V9.1 (All versions < V9.1 SP2 Upd3), SIMATIC S7-PCT (All versions < V3.5 SP3 Update 6), SIMATIC STEP 7 V5 (All versions < V5.7 SP3), SIMATIC WinCC OA V3.17 (All versions), SIMATIC WinCC OA V3.18 (All versions < V3.18 P025), SIMATIC WinCC OA V3.19 (All versions < V3.19 P010), SIMATIC WinCC Runtime Advanced (All versions < V17 Update 8), SIMATIC WinCC Runtime Professional V16 (All versions < V16 Update 6), SIMATIC WinCC Runtime Professional V17 (All versions < V17 Update 8), SIMATIC WinCC Runtime Professional V18 (All versions < V18 Update 4), SIMATIC WinCC Runtime Professional V19 (All versions < V19 Update 2), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 17), SIMATIC WinCC V8.0 (All versions < V8.0 Update 5), SINAMICS Startdrive (All versions < V19 SP1), SINEC NMS (All versions < V3.0), SINEC NMS (All versions < V3.0 SP1), SINUMERIK ONE virtual (All versions < V6.23), SINUMERIK PLC Programming Tool (All versions < V3.3.12), TIA Portal Cloud Connector (All versions < V2.0), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 4), Totally Integrated Automation Portal (TIA Portal) V19 (All versions < V19 Update 2). The affected applications contain an out of bounds read vulnerability. This could allow an attacker to cause a Blue Screen of Death (BSOD) crash of the underlying Windows kernel. S7 PCT (Port Configuration Tool) is a PC-based software for parameterizing Siemens IO-Link master modules and third-party IO-Link devices. Security Configuration Tool (SCT) is an engineering software for safety devices such as SCALANCE-S or CP 443-1Advanced. SIMATIC Automation Tool allows commissioning, adjustment and service in combination with S7-1200 and S7-1500 controllers without an engineering framework. SIMATIC NET PC software is a separately sold software product for implementing communication products for SIMATIC.NET. SIMATIC PCS 7 is a distributed control system (DCS) that integrates SIMATIC WinCC, SIMATIC Batch, SIMATIC Route control, OpenPCS 7 and other components. SIMATIC PDM (Process Device Manager) is a universal, manufacturer-independent tool for configuration, parameter assignment, commissioning, diagnostics and maintenance of intelligent process devices (actuators, sensors) and automation components (remote I/O, multiplexers, process control units, compact controllers). SIMATIC STEP 7 V5 is the classic engineering software for configuring and programming SIMATIC S7-300/S7-400/C7/WinAC controllers. SIMATIC WinCC is a Supervisory Control and Data Acquisition (SCADA) system. SIMATIC WinCC Open Architecture (OA) is part of the SIMATIC HMI family. It is designed for applications that require a high degree of customer-specific adaptability, large or complex applications, and projects that impose specific system requirements or functions. SIMATIC WinCC Runtime Advanced is a visualization runtime platform for operator control and monitoring of machines and plants. SIMATIC WinCC Runtime Professional is a visualization runtime platform for operator control and monitoring of machines and plants. SIMATIC WinCC Unified PC Runtime is a new visualization runtime platform for operator control and monitoring of machines and plants. SINAMICS Startdrive commissioning software is the engineering tool for integrating SINAMICS drives in the TIA Portal. SINUMERIK CNC provides automation solutions for workshops, shop floors and large serial production environments. SINUMERIK ONE is a digital native CNC system. Totally Integrated Automation Portal (TIA Portal) is a PC software that provides the complete range of Siemens digital automation services, from digital planning and integrated engineering to transparent operation. TIA Portal Cloud Connector enables access to local PG/PC interfaces and connected SIMATIC hardware from TIA Portal Engineering when engineering via remote desktop on a private cloud server

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202405-0210",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "security configuration tool",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic automation tool",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic net pc software",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic wincc runtime advanced",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic wincc oa",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v3.17"
      },
      {
        "model": "totally integrated automation portal",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v16"
      },
      {
        "model": "totally integrated automation portal",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v17"
      },
      {
        "model": "totally integrated automation portal",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v18"
      },
      {
        "model": "totally integrated automation portal",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v15.1"
      },
      {
        "model": "simatic pcs",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "7v9.1"
      },
      {
        "model": "simatic wincc runtime professional",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v17"
      },
      {
        "model": "simatic wincc runtime professional",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v18"
      },
      {
        "model": "simatic wincc runtime professional",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v19"
      },
      {
        "model": "simatic wincc",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v8.0"
      },
      {
        "model": "totally integrated automation portal update",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v19\u003cv192"
      },
      {
        "model": "tia portal cloud connector",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v2.0"
      },
      {
        "model": "sinumerik plc programming tool",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinumerik one virtual",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v6.23"
      },
      {
        "model": "sinamics startdrive sp1",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v19"
      },
      {
        "model": "simatic wincc",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v7.5"
      },
      {
        "model": "simatic wincc",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v7.4"
      },
      {
        "model": "simatic wincc unified pc runtime",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic wincc runtime professional",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v16"
      },
      {
        "model": "simatic wincc oa p010",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v3.19\u003cv3.19"
      },
      {
        "model": "simatic wincc oa p025",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v3.18\u003cv3.18"
      },
      {
        "model": "simatic step",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "7v5"
      },
      {
        "model": "simatic route control",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v9.1"
      },
      {
        "model": "simatic pdm",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v9.2"
      },
      {
        "model": "simatic batch",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v9.1"
      },
      {
        "model": "s7-pct",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-24524"
      }
    ]
  },
  "cve": "CVE-2023-46280",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "LOCAL",
            "authentication": "SINGLE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 4.6,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 3.1,
            "id": "CNVD-2024-24524",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 0.6,
            "vectorString": "AV:L/AC:L/Au:S/C:N/I:N/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "author": "productcert@siemens.com",
            "availabilityImpact": "HIGH",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 2.0,
            "id": "CVE-2023-46280",
            "impactScore": 4.0,
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "CHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:N/I:N/A:H",
            "version": "3.1"
          }
        ],
        "severity": [
          {
            "author": "productcert@siemens.com",
            "id": "CVE-2023-46280",
            "trust": 1.0,
            "value": "High"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2024-24524",
            "trust": 0.6,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-24524"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-46280"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A vulnerability has been identified in Security Configuration Tool (SCT) (All versions), SIMATIC Automation Tool (All versions \u003c V5.0 SP2), SIMATIC BATCH V9.1 (All versions \u003c V9.1 SP2 Upd5), SIMATIC NET PC Software V16 (All versions \u003c V16 Update 8), SIMATIC NET PC Software V17 (All versions), SIMATIC NET PC Software V18 (All versions \u003c V18 SP1), SIMATIC NET PC Software V19 (All versions \u003c V19 Update 2), SIMATIC PCS 7 V9.1 (All versions \u003c V9.1 SP2 UC05), SIMATIC PDM V9.2 (All versions \u003c V9.2 SP2 Upd3), SIMATIC Route Control V9.1 (All versions \u003c V9.1 SP2 Upd3), SIMATIC S7-PCT (All versions \u003c V3.5 SP3 Update 6), SIMATIC STEP 7 V5 (All versions \u003c V5.7 SP3), SIMATIC WinCC OA V3.17 (All versions), SIMATIC WinCC OA V3.18 (All versions \u003c V3.18 P025), SIMATIC WinCC OA V3.19 (All versions \u003c V3.19 P010), SIMATIC WinCC Runtime Advanced (All versions \u003c V17 Update 8), SIMATIC WinCC Runtime Professional V16 (All versions \u003c V16 Update 6), SIMATIC WinCC Runtime Professional V17 (All versions \u003c V17 Update 8), SIMATIC WinCC Runtime Professional V18 (All versions \u003c V18 Update 4), SIMATIC WinCC Runtime Professional V19 (All versions \u003c V19 Update 2), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions \u003c V7.5 SP2 Update 17), SIMATIC WinCC V8.0 (All versions \u003c V8.0 Update 5), SINAMICS Startdrive (All versions \u003c V19 SP1), SINEC NMS (All versions \u003c V3.0), SINEC NMS (All versions \u003c V3.0 SP1), SINUMERIK ONE virtual (All versions \u003c V6.23), SINUMERIK PLC Programming Tool (All versions \u003c V3.3.12), TIA Portal Cloud Connector (All versions \u003c V2.0), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions \u003c V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions \u003c V18 Update 4), Totally Integrated Automation Portal (TIA Portal) V19 (All versions \u003c V19 Update 2). The affected applications contain an out of bounds read vulnerability. This could allow an attacker to cause a Blue Screen of Death (BSOD) crash of the underlying Windows kernel. S7 PCT (Port Configuration Tool) is a PC-based software for parameterizing Siemens IO-Link master modules and third-party IO-Link devices. Security Configuration Tool (SCT) is an engineering software for safety devices such as SCALANCE-S or CP 443-1Advanced. SIMATIC Automation Tool allows commissioning, adjustment and service in combination with S7-1200 and S7-1500 controllers without an engineering framework. SIMATIC NET PC software is a separately sold software product for implementing communication products for SIMATIC.NET. SIMATIC PCS 7 is a distributed control system (DCS) that integrates SIMATIC WinCC, SIMATIC Batch, SIMATIC Route control, OpenPCS 7 and other components. SIMATIC PDM (Process Device Manager) is a universal, manufacturer-independent tool for configuration, parameter assignment, commissioning, diagnostics and maintenance of intelligent process devices (actuators, sensors) and automation components (remote I/O, multiplexers, process control units, compact controllers). SIMATIC STEP 7 V5 is the classic engineering software for configuring and programming SIMATIC S7-300/S7-400/C7/WinAC controllers. SIMATIC WinCC is a Supervisory Control and Data Acquisition (SCADA) system. SIMATIC WinCC Open Architecture (OA) is part of the SIMATIC HMI family. It is designed for applications that require a high degree of customer-specific adaptability, large or complex applications, and projects that impose specific system requirements or functions. SIMATIC WinCC Runtime Advanced is a visualization runtime platform for operator control and monitoring of machines and plants. SIMATIC WinCC Runtime Professional is a visualization runtime platform for operator control and monitoring of machines and plants. SIMATIC WinCC Unified PC Runtime is a new visualization runtime platform for operator control and monitoring of machines and plants. SINAMICS Startdrive commissioning software is the engineering tool for integrating SINAMICS drives in the TIA Portal. SINUMERIK CNC provides automation solutions for workshops, shop floors and large serial production environments. SINUMERIK ONE is a digital native CNC system. Totally Integrated Automation Portal (TIA Portal) is a PC software that provides the complete range of Siemens digital automation services, from digital planning and integrated engineering to transparent operation. TIA Portal Cloud Connector enables access to local PG/PC interfaces and connected SIMATIC hardware from TIA Portal Engineering when engineering via remote desktop on a private cloud server",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2023-46280"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2024-24524"
      }
    ],
    "trust": 1.44
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "SIEMENS",
        "id": "SSA-962515",
        "trust": 1.6
      },
      {
        "db": "NVD",
        "id": "CVE-2023-46280",
        "trust": 1.6
      },
      {
        "db": "SIEMENS",
        "id": "SSA-784301",
        "trust": 1.0
      },
      {
        "db": "SIEMENS",
        "id": "SSA-331112",
        "trust": 1.0
      },
      {
        "db": "CNVD",
        "id": "CNVD-2024-24524",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-24524"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-46280"
      }
    ]
  },
  "id": "VAR-202405-0210",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-24524"
      }
    ],
    "trust": 1.2706952166666665
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-24524"
      }
    ]
  },
  "last_update_date": "2024-12-10T21:17:15.299000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Patch for Siemens Industrial Products Out-of-Bounds Read Vulnerability",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/547666"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-24524"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-125",
        "trust": 1.0
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2023-46280"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.6,
        "url": "https://cert-portal.siemens.com/productcert/html/ssa-962515.html"
      },
      {
        "trust": 1.0,
        "url": "https://cert-portal.siemens.com/productcert/html/ssa-331112.html"
      },
      {
        "trust": 1.0,
        "url": "https://cert-portal.siemens.com/productcert/html/ssa-784301.html"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-24524"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-46280"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-24524"
      },
      {
        "db": "NVD",
        "id": "CVE-2023-46280"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2024-05-30T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2024-24524"
      },
      {
        "date": "2024-05-14T16:15:40.800000",
        "db": "NVD",
        "id": "CVE-2023-46280"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2024-05-28T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2024-24524"
      },
      {
        "date": "2024-12-10T14:30:35.147000",
        "db": "NVD",
        "id": "CVE-2023-46280"
      }
    ]
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Siemens Industrial Products Out-of-Bounds Read Vulnerability",
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-24524"
      }
    ],
    "trust": 0.6
  }
}

VAR-201904-0176

Vulnerability from variot - Updated: 2024-11-23 22:45

A vulnerability has been identified in SIMATIC CP 443-1 OPC UA (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V2.7), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (incl. SIPLUS variants) (All versions < V15.1 Upd 4), SIMATIC HMI Comfort Panels 4" - 22" (incl. SIPLUS variants) (All versions < V15.1 Upd 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Upd 4), SIMATIC IPC DiagMonitor (All versions < V5.1.3), SIMATIC NET PC Software V13 (All versions), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC RF188C (All versions < V1.1.0), SIMATIC RF600R family (All versions < V3.2.1), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.5 < V2.6.1), SIMATIC S7-1500 Software Controller (All versions between V2.5 (including) and V2.7 (excluding)), SIMATIC WinCC OA (All versions < V3.15 P018), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Upd 4), SINEC NMS (All versions < V1.0 SP1), SINEMA Server (All versions < V14 SP2), SINUMERIK OPC UA Server (All versions < V2.1), TeleControl Server Basic (All versions < V3.1.1). Specially crafted network packets sent to affected devices on port 4840/tcp could allow an unauthenticated remote attacker to cause a denial of service condition of the OPC communication or crash the device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the OPC communication. plural Siemens The product contains an input validation vulnerability.Service operation interruption (DoS) There is a possibility of being put into a state. Siemens is a leading global technology company that provides solutions to customers in the areas of power generation and transmission and distribution, infrastructure, industrial automation, drive and software with innovation in electrification, automation and digital. Siemens has a denial of service vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known. Siemens SIMATIC S7-1500 CPU, etc. are all products of German Siemens (Siemens). SIMATIC S7-1500 CPU is a CPU (central processing unit) module. SIMATIC S7-1500 is a programmable logic controller. SIMATIC WinCC is an automated data acquisition and monitoring (SCADA) system. The vulnerability stems from the failure of the network system or product to properly validate the input data

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201904-0176",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "simatic wincc runtime advanced",
        "scope": null,
        "trust": 1.4,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic net pc software",
        "scope": null,
        "trust": 1.4,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic rf188c",
        "scope": null,
        "trust": 1.4,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic rf600r",
        "scope": null,
        "trust": 1.4,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic ipc diagmonitor",
        "scope": null,
        "trust": 1.4,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic hmi comfort outdoor panels",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "simatic s7-1500t",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.5"
      },
      {
        "model": "simatic hmi ktp mobile panels ktp700f",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "simatic hmi ktp mobile panels ktp900f",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "simatic hmi comfort outdoor panels",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "simatic hmi ktp mobile panels ktp900",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "simatic hmi ktp mobile panels ktp900f",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "simatic et 200 open controller cpu 1515sp pc2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.7"
      },
      {
        "model": "simatic rf188c",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic wincc oa",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "3.15-p018"
      },
      {
        "model": "simatic wincc runtime advanced",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic ipc diagmonitor",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic wincc runtime mobile",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic s7-1500s",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.5"
      },
      {
        "model": "simatic hmi ktp mobile panels ktp700",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "simatic hmi ktp mobile panels ktp900",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "sinec-nms",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "1.0"
      },
      {
        "model": "simatic hmi ktp mobile panels ktp700",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "simatic hmi ktp mobile panels ktp400f",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "simatic cp443-1 opc ua",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic rf600r",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic s7-1500",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.5"
      },
      {
        "model": "sinec-nms",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "1.0"
      },
      {
        "model": "simatic s7-1500f",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.5"
      },
      {
        "model": "sinema server",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic net pc software",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "sinumerik opc ua server",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.1"
      },
      {
        "model": "simatic hmi ktp mobile panels ktp400f",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "simatic wincc runtime comfort",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "opc unified architecture",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic s7-1500 software controller",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.5"
      },
      {
        "model": "simatic hmi ktp mobile panels ktp700f",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "telecontrol server basic",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "3.1.1"
      },
      {
        "model": "simatic wincc runtime hsp comfort",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic cp 443-1 opc-ua",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic et 200 open controller cpu 1515sp pc2",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic s7-1500 software controller",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic s7-1500",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic wincc oa",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic s7-1500 cpu family",
        "scope": "lte",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "\u003c=v2.5"
      },
      {
        "model": "simatic s7-1500 software controller",
        "scope": "lte",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "\u003c=v2.5"
      },
      {
        "model": "simatic wincc oa \u003cv3.15-p018",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinema server",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinumerik opc ua server",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v2.1"
      },
      {
        "model": "telecontrol server basics",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic wincc runtime comfort",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic wincc runtime mobile",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinec-nms",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic cp443-1 opc ua",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic et200 open controller cpu 1515sp pc2",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic wincc runtime hsp comfort",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "telecontrol server basic",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "3.1"
      },
      {
        "model": "telecontrol server basic sp2",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "3.0"
      },
      {
        "model": "telecontrol server basic",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "3.0"
      },
      {
        "model": "sinumerik opc ua server",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "sinema server",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "sinec-nms",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic wincc runtime mobile",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic wincc runtime hsp comfort",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic wincc runtime comfort",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic wincc runtime advanced",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic wincc oa",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "3.15"
      },
      {
        "model": "simatic wincc oa 3.14-p021",
        "scope": null,
        "trust": 0.3,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic wincc oa",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "3.14"
      },
      {
        "model": "simatic wincc oa p002",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "3.12"
      },
      {
        "model": "simatic wincc oa",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "3.12"
      },
      {
        "model": "simatic s7-1500 software controller",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "1.7"
      },
      {
        "model": "simatic s7-1500 software controller",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "2.5"
      },
      {
        "model": "simatic s7-1500 software controller",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "2.0"
      },
      {
        "model": "simatic s7-1500",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "1.8.5"
      },
      {
        "model": "simatic s7-1500",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "1.8.3"
      },
      {
        "model": "simatic s7-1500",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "1.7"
      },
      {
        "model": "simatic s7-1500",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "2.5"
      },
      {
        "model": "simatic s7-1500",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "2.0"
      },
      {
        "model": "simatic s7-1500",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "1.6"
      },
      {
        "model": "simatic s7-1500",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "1.5.0"
      },
      {
        "model": "simatic rf600r",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic rf188c",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic net pc software",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic ipc diagmonitor",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic et200 open controller cpu 1515sp pc2",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic cp opc ua",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "443-10"
      },
      {
        "model": "sinumerik opc ua server",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "2.1"
      },
      {
        "model": "simatic wincc oa 3.15-p018",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic cp443 1 opc ua",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic s7 1500s",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic s7 1500t",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic et 200 open controller cpu 1515sp pc2",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic ipc diagmonitor",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic net pc",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic rf188c",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic rf600r",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic s7 1500",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic s7 1500 controller",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic wincc oa",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic wincc runtime advanced",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic wincc runtime comfort",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic wincc runtime hsp comfort",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic wincc runtime mobile",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sinec nms",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sinema server",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sinumerik opc ua server",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "telecontrol server basic",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic s7 1500f",
        "version": "*"
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "b72b932a-ffe5-40c4-80a7-5e3f71b449fc"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-12905"
      },
      {
        "db": "BID",
        "id": "107833"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-003488"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-6575"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_cp_443-1_std_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_et_200_open_controller_cpu_1515sp_pc2_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_ipc_diagmonitor_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/a:siemens:simatic_net_pc-software",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_rf188c_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_rf600r_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_s7-1500_software_controller_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_s7-1500_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/a:siemens:simatic_wincc_open_architecture",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/a:siemens:wincc_runtime_advanced",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-003488"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Siemens,Siemens ProductCERT reported this vulnerability to NCCIC.",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201904-462"
      }
    ],
    "trust": 0.6
  },
  "cve": "CVE-2019-6575",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.8,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "CVE-2019-6575",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "HIGH",
            "trust": 1.9,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.8,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2019-12905",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "IVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.8,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "b72b932a-ffe5-40c4-80a7-5e3f71b449fc",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "HIGH",
            "trust": 0.2,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
            "version": "2.9 [IVD]"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.8,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "VHN-158010",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "HIGH",
            "trust": 0.1,
            "vectorString": "AV:N/AC:L/AU:N/C:N/I:N/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 3.9,
            "id": "CVE-2019-6575",
            "impactScore": 3.6,
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 7.5,
            "baseSeverity": "High",
            "confidentialityImpact": "None",
            "exploitabilityScore": null,
            "id": "CVE-2019-6575",
            "impactScore": null,
            "integrityImpact": "None",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2019-6575",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "NVD",
            "id": "CVE-2019-6575",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2019-12905",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201904-462",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "IVD",
            "id": "b72b932a-ffe5-40c4-80a7-5e3f71b449fc",
            "trust": 0.2,
            "value": "HIGH"
          },
          {
            "author": "VULHUB",
            "id": "VHN-158010",
            "trust": 0.1,
            "value": "HIGH"
          },
          {
            "author": "VULMON",
            "id": "CVE-2019-6575",
            "trust": 0.1,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "b72b932a-ffe5-40c4-80a7-5e3f71b449fc"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-12905"
      },
      {
        "db": "VULHUB",
        "id": "VHN-158010"
      },
      {
        "db": "VULMON",
        "id": "CVE-2019-6575"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-003488"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201904-462"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-6575"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A vulnerability has been identified in SIMATIC CP 443-1 OPC UA (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003c V2.7), SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (incl. SIPLUS variants) (All versions \u003c V15.1 Upd 4), SIMATIC HMI Comfort Panels 4\" - 22\" (incl. SIPLUS variants) (All versions \u003c V15.1 Upd 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15.1 Upd 4), SIMATIC IPC DiagMonitor (All versions \u003c V5.1.3), SIMATIC NET PC Software V13 (All versions), SIMATIC NET PC Software V14 (All versions \u003c V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC RF188C (All versions \u003c V1.1.0), SIMATIC RF600R family (All versions \u003c V3.2.1), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003e= V2.5 \u003c V2.6.1), SIMATIC S7-1500 Software Controller (All versions between V2.5 (including) and V2.7 (excluding)), SIMATIC WinCC OA (All versions \u003c V3.15 P018), SIMATIC WinCC Runtime Advanced (All versions \u003c V15.1 Upd 4), SINEC NMS (All versions \u003c V1.0 SP1), SINEMA Server (All versions \u003c V14 SP2), SINUMERIK OPC UA Server (All versions \u003c V2.1), TeleControl Server Basic (All versions \u003c V3.1.1). Specially crafted network packets sent to affected devices on port 4840/tcp could allow an unauthenticated remote attacker to cause a denial of service condition of the OPC communication or crash the device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the OPC communication. plural Siemens The product contains an input validation vulnerability.Service operation interruption (DoS) There is a possibility of being put into a state. Siemens is a leading global technology company that provides solutions to customers in the areas of power generation and transmission and distribution, infrastructure, industrial automation, drive and software with innovation in electrification, automation and digital. Siemens has a denial of service vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known. Siemens SIMATIC S7-1500 CPU, etc. are all products of German Siemens (Siemens). SIMATIC S7-1500 CPU is a CPU (central processing unit) module. SIMATIC S7-1500 is a programmable logic controller. SIMATIC WinCC is an automated data acquisition and monitoring (SCADA) system. The vulnerability stems from the failure of the network system or product to properly validate the input data",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2019-6575"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-003488"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-12905"
      },
      {
        "db": "BID",
        "id": "107833"
      },
      {
        "db": "IVD",
        "id": "b72b932a-ffe5-40c4-80a7-5e3f71b449fc"
      },
      {
        "db": "VULHUB",
        "id": "VHN-158010"
      },
      {
        "db": "VULMON",
        "id": "CVE-2019-6575"
      }
    ],
    "trust": 2.79
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2019-6575",
        "trust": 3.7
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-19-099-03",
        "trust": 2.4
      },
      {
        "db": "SIEMENS",
        "id": "SSA-307392",
        "trust": 1.8
      },
      {
        "db": "BID",
        "id": "107833",
        "trust": 1.1
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201904-462",
        "trust": 0.9
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-12905",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-003488",
        "trust": 0.8
      },
      {
        "db": "AUSCERT",
        "id": "ESB-2019.1205",
        "trust": 0.6
      },
      {
        "db": "IVD",
        "id": "B72B932A-FFE5-40C4-80A7-5E3F71B449FC",
        "trust": 0.2
      },
      {
        "db": "VULHUB",
        "id": "VHN-158010",
        "trust": 0.1
      },
      {
        "db": "VULMON",
        "id": "CVE-2019-6575",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "b72b932a-ffe5-40c4-80a7-5e3f71b449fc"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-12905"
      },
      {
        "db": "VULHUB",
        "id": "VHN-158010"
      },
      {
        "db": "VULMON",
        "id": "CVE-2019-6575"
      },
      {
        "db": "BID",
        "id": "107833"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-003488"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201904-462"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-6575"
      }
    ]
  },
  "id": "VAR-201904-0176",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "IVD",
        "id": "b72b932a-ffe5-40c4-80a7-5e3f71b449fc"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-12905"
      },
      {
        "db": "VULHUB",
        "id": "VHN-158010"
      }
    ],
    "trust": 1.5723463029411764
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS",
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      },
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.2
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "b72b932a-ffe5-40c4-80a7-5e3f71b449fc"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-12905"
      }
    ]
  },
  "last_update_date": "2024-11-23T22:45:04.929000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "SSA-307392",
        "trust": 0.8,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-307392.pdf"
      },
      {
        "title": "SiemensIndustrialProductswithOPCUA denial of service vulnerability patch",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/160239"
      },
      {
        "title": "Siemens OPC UA Security vulnerabilities",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=91290"
      },
      {
        "title": "Siemens Security Advisories: Siemens Security Advisory",
        "trust": 0.1,
        "url": "https://vulmon.com/vendoradvisory?qidtp=siemens_security_advisories\u0026qid=f300e0ed579e6a7eeebba4d6b8703ede"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-12905"
      },
      {
        "db": "VULMON",
        "id": "CVE-2019-6575"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-003488"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201904-462"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-755",
        "trust": 1.1
      },
      {
        "problemtype": "CWE-248",
        "trust": 1.0
      },
      {
        "problemtype": "CWE-20",
        "trust": 0.9
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-158010"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-003488"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-6575"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.3,
        "url": "https://ics-cert.us-cert.gov/advisories/icsa-19-099-03"
      },
      {
        "trust": 1.8,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-307392.pdf"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2019-6575"
      },
      {
        "trust": 0.9,
        "url": "http://www.siemens.com/"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-6575"
      },
      {
        "trust": 0.7,
        "url": "https://www.securityfocus.com/bid/107833"
      },
      {
        "trust": 0.6,
        "url": "https://vigilance.fr/vulnerability/siemens-simatic-denial-of-service-via-opc-ua-4840-tcp-28974"
      },
      {
        "trust": 0.6,
        "url": "https://www.us-cert.gov/ics/advisories/icsa-19-099-03"
      },
      {
        "trust": 0.6,
        "url": "https://www.auscert.org.au/bulletins/78742"
      },
      {
        "trust": 0.1,
        "url": "https://cwe.mitre.org/data/definitions/755.html"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      },
      {
        "trust": 0.1,
        "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-19-099-03"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-12905"
      },
      {
        "db": "VULHUB",
        "id": "VHN-158010"
      },
      {
        "db": "VULMON",
        "id": "CVE-2019-6575"
      },
      {
        "db": "BID",
        "id": "107833"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-003488"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201904-462"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-6575"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "IVD",
        "id": "b72b932a-ffe5-40c4-80a7-5e3f71b449fc"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-12905"
      },
      {
        "db": "VULHUB",
        "id": "VHN-158010"
      },
      {
        "db": "VULMON",
        "id": "CVE-2019-6575"
      },
      {
        "db": "BID",
        "id": "107833"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-003488"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201904-462"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-6575"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2019-05-05T00:00:00",
        "db": "IVD",
        "id": "b72b932a-ffe5-40c4-80a7-5e3f71b449fc"
      },
      {
        "date": "2019-05-05T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2019-12905"
      },
      {
        "date": "2019-04-17T00:00:00",
        "db": "VULHUB",
        "id": "VHN-158010"
      },
      {
        "date": "2019-04-17T00:00:00",
        "db": "VULMON",
        "id": "CVE-2019-6575"
      },
      {
        "date": "2019-04-09T00:00:00",
        "db": "BID",
        "id": "107833"
      },
      {
        "date": "2019-05-17T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2019-003488"
      },
      {
        "date": "2019-04-09T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201904-462"
      },
      {
        "date": "2019-04-17T14:29:03.760000",
        "db": "NVD",
        "id": "CVE-2019-6575"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2019-05-07T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2019-12905"
      },
      {
        "date": "2020-10-16T00:00:00",
        "db": "VULHUB",
        "id": "VHN-158010"
      },
      {
        "date": "2022-04-12T00:00:00",
        "db": "VULMON",
        "id": "CVE-2019-6575"
      },
      {
        "date": "2019-04-09T00:00:00",
        "db": "BID",
        "id": "107833"
      },
      {
        "date": "2019-05-17T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2019-003488"
      },
      {
        "date": "2022-08-11T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201904-462"
      },
      {
        "date": "2024-11-21T04:46:43.960000",
        "db": "NVD",
        "id": "CVE-2019-6575"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201904-462"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Siemens Industrial Products with OPC UA Denial of service vulnerability",
    "sources": [
      {
        "db": "IVD",
        "id": "b72b932a-ffe5-40c4-80a7-5e3f71b449fc"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-12905"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Input validation error",
    "sources": [
      {
        "db": "IVD",
        "id": "b72b932a-ffe5-40c4-80a7-5e3f71b449fc"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201904-462"
      }
    ],
    "trust": 0.8
  }
}

VAR-201812-0345

Vulnerability from variot - Updated: 2024-11-23 22:34

A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V14), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V14), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V14), SIMATIC WinCC Runtime Advanced (All versions < V14), SIMATIC WinCC Runtime Professional (All versions < V14), SIMATIC WinCC (TIA Portal) (All versions < V14), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The integrated web server (port 80/tcp and port 443/tcp) of the affected devices could allow an attacker to inject HTTP headers. An attacker must trick a valid user who is authenticated to the device into clicking on a malicious link to exploit the vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known. plural SIMATIC The product contains an input validation vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Siemens SIMATIC Panels and SIMATIC WinCC (TIA Portal) are products of Siemens AG, Germany. Siemens SIMATIC Panels is a human interface panel. SIMATIC WinCC is an automated data acquisition and monitoring (SCADA) system. A code injection vulnerability exists in Siemens SIMATIC Panels and SIMATIC WinCC (TIA Portal), which can be exploited by an attacker to inject HTTP headers with malicious links. Multiple Siemens Products are prone to an HTTP header-injection vulnerability because it fails to sufficiently sanitize user input. This may aid in further attacks

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201812-0345",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "simatic hmi ktp mobile panels ktp900",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "14.0"
      },
      {
        "model": "simatic hmi ktp mobile panels ktp400f",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "14.0"
      },
      {
        "model": "simatic hmi mp",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic hmi op",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic hmi ktp mobile panels ktp700",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "14.0"
      },
      {
        "model": "simatic wincc \\",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "14.0"
      },
      {
        "model": "simatic hmi comfort outdoor panels",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "14.0"
      },
      {
        "model": "simatic wincc runtime",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "14.0"
      },
      {
        "model": "simatic hmi ktp mobile panels ktp900f",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "14.0"
      },
      {
        "model": "simatic hmi ktp mobile panels ktp700f",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "14.0"
      },
      {
        "model": "simatic hmi tp",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic hmi comfort panels",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "14.0"
      },
      {
        "model": "simatic hmi comfort outdoor panels",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic hmi comfort panels",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic hmi ktp mobile panels ktp400f",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic hmi ktp mobile panels ktp700",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic hmi ktp mobile panels ktp700f",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic hmi ktp mobile panels ktp900",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic hmi ktp mobile panels ktp900f",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic wincc",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic wincc runtime advanced",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic wincc runtime professional",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic hmi comfort panels 4\" 22\"",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "-\u003c14"
      },
      {
        "model": "simatic hmi comfort outdoor panels 7\\\" and 15\\\"",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "14"
      },
      {
        "model": "simatic hmi ktp mobile panels",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "14"
      },
      {
        "model": "simatic wincc runtime advanced",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "14"
      },
      {
        "model": "simatic wincc runtime professional",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "14"
      },
      {
        "model": "simatic wincc",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "14"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.4,
        "vendor": "simatic wincc runtime",
        "version": "*"
      },
      {
        "model": "simatic wincc runtime professional",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "13"
      },
      {
        "model": "simatic wincc runtime professional",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic wincc runtime advanced",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "13"
      },
      {
        "model": "simatic wincc runtime advanced",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "12"
      },
      {
        "model": "simatic wincc runtime advanced",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic wincc",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "v120"
      },
      {
        "model": "simatic wincc",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "v110"
      },
      {
        "model": "simatic wincc",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "v13"
      },
      {
        "model": "simatic wincc",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "v10"
      },
      {
        "model": "simatic hmi ktp mobile panels",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic hmi comfort panels",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4"
      },
      {
        "model": "simatic hmi comfort panels",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "22"
      },
      {
        "model": "simatic hmi comfort panels",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "13"
      },
      {
        "model": "simatic hmi comfort panels",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "12"
      },
      {
        "model": "simatic hmi comfort panels",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic hmi comfort outdoor panels",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic hmi classic devices",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic wincc runtime professional",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "14"
      },
      {
        "model": "simatic wincc runtime advanced",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "v14"
      },
      {
        "model": "simatic wincc",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "v14"
      },
      {
        "model": "simatic hmi ktp mobile panels update",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "154"
      },
      {
        "model": "simatic hmi comfort panels",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "14"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic hmi comfort panels",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic hmi mp",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic hmi op",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic hmi comfort outdoor panels",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic hmi ktp mobile panels ktp400f",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic hmi ktp mobile panels ktp700",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic hmi ktp mobile panels ktp700f",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic hmi ktp mobile panels ktp900",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic hmi ktp mobile panels ktp900f",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic wincc tia portal",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic hmi tp",
        "version": "*"
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "7d80ae62-463f-11e9-b905-000c29342cb1"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-25432"
      },
      {
        "db": "BID",
        "id": "105931"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-014527"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-13814"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_hmi_comfort_outdoor_panels_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_hmi_comfort_panels",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/a:siemens:simatic_wincc_%28tia_portal%29",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/a:siemens:wincc_runtime_advanced",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/a:siemens:simatic_wincc_runtime_professional",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-014527"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "The vendor reported this issue.",
    "sources": [
      {
        "db": "BID",
        "id": "105931"
      }
    ],
    "trust": 0.3
  },
  "cve": "CVE-2018-13814",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "PARTIAL",
            "baseScore": 6.8,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 8.6,
            "id": "CVE-2018-13814",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 1.8,
            "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "NONE",
            "baseScore": 5.0,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2018-25432",
            "impactScore": 2.9,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:N",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "IVD",
            "availabilityImpact": "NONE",
            "baseScore": 5.0,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "7d80ae62-463f-11e9-b905-000c29342cb1",
            "impactScore": 2.9,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 0.2,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:N",
            "version": "2.9 [IVD]"
          },
          {
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "PARTIAL",
            "baseScore": 6.8,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 8.6,
            "id": "VHN-123911",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 0.1,
            "vectorString": "AV:N/AC:M/AU:N/C:P/I:P/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 2.8,
            "id": "CVE-2018-13814",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.8,
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2018-13814",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "NVD",
            "id": "CVE-2018-13814",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2018-25432",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201811-488",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "IVD",
            "id": "7d80ae62-463f-11e9-b905-000c29342cb1",
            "trust": 0.2,
            "value": "HIGH"
          },
          {
            "author": "VULHUB",
            "id": "VHN-123911",
            "trust": 0.1,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "7d80ae62-463f-11e9-b905-000c29342cb1"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-25432"
      },
      {
        "db": "VULHUB",
        "id": "VHN-123911"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-014527"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201811-488"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-13814"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A vulnerability has been identified in SIMATIC HMI Comfort Panels 4\" - 22\" (All versions \u003c V14), SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (All versions \u003c V14), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V14), SIMATIC WinCC Runtime Advanced (All versions \u003c V14), SIMATIC WinCC Runtime Professional (All versions \u003c V14), SIMATIC WinCC (TIA Portal) (All versions \u003c V14), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The integrated web server (port 80/tcp and port 443/tcp) of the affected devices could allow an attacker to inject HTTP headers. An attacker must trick a valid user who is authenticated to the device into clicking on a malicious link to exploit the vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known. plural SIMATIC The product contains an input validation vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Siemens SIMATIC Panels and SIMATIC WinCC (TIA Portal) are products of Siemens AG, Germany. Siemens SIMATIC Panels is a human interface panel. SIMATIC WinCC is an automated data acquisition and monitoring (SCADA) system. A code injection vulnerability exists in Siemens SIMATIC Panels and SIMATIC WinCC (TIA Portal), which can be exploited by an attacker to inject HTTP headers with malicious links. Multiple Siemens Products are prone to an HTTP header-injection vulnerability because it fails to sufficiently sanitize user input. This may aid in further attacks",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2018-13814"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-014527"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-25432"
      },
      {
        "db": "BID",
        "id": "105931"
      },
      {
        "db": "IVD",
        "id": "7d80ae62-463f-11e9-b905-000c29342cb1"
      },
      {
        "db": "VULHUB",
        "id": "VHN-123911"
      }
    ],
    "trust": 2.7
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2018-13814",
        "trust": 3.6
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-18-317-03",
        "trust": 2.3
      },
      {
        "db": "BID",
        "id": "105931",
        "trust": 2.0
      },
      {
        "db": "SIEMENS",
        "id": "SSA-944083",
        "trust": 1.7
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201811-488",
        "trust": 0.9
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-25432",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-014527",
        "trust": 0.8
      },
      {
        "db": "IVD",
        "id": "7D80AE62-463F-11E9-B905-000C29342CB1",
        "trust": 0.2
      },
      {
        "db": "SEEBUG",
        "id": "SSVID-98853",
        "trust": 0.1
      },
      {
        "db": "VULHUB",
        "id": "VHN-123911",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "7d80ae62-463f-11e9-b905-000c29342cb1"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-25432"
      },
      {
        "db": "VULHUB",
        "id": "VHN-123911"
      },
      {
        "db": "BID",
        "id": "105931"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-014527"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201811-488"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-13814"
      }
    ]
  },
  "id": "VAR-201812-0345",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "IVD",
        "id": "7d80ae62-463f-11e9-b905-000c29342cb1"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-25432"
      },
      {
        "db": "VULHUB",
        "id": "VHN-123911"
      }
    ],
    "trust": 1.53959078625
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "7d80ae62-463f-11e9-b905-000c29342cb1"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-25432"
      }
    ]
  },
  "last_update_date": "2024-11-23T22:34:04.145000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "SSA-944083",
        "trust": 0.8,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-944083.pdf"
      },
      {
        "title": "Patch for Siemens SIMATIC Panels and SIMATIC WinCC code injection vulnerability",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/147353"
      },
      {
        "title": "Siemens SIMATIC Panels  and SIMATIC WinCC Fixes for code injection vulnerabilities",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=86889"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-25432"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-014527"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201811-488"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-20",
        "trust": 1.9
      },
      {
        "problemtype": "CWE-113",
        "trust": 1.0
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-123911"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-014527"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-13814"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.3,
        "url": "https://ics-cert.us-cert.gov/advisories/icsa-18-317-03"
      },
      {
        "trust": 1.7,
        "url": "http://www.securityfocus.com/bid/105931"
      },
      {
        "trust": 1.7,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-944083.pdf"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-13814"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2018-13814"
      },
      {
        "trust": 0.3,
        "url": "http://subscriber.communications.siemens.com/"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-25432"
      },
      {
        "db": "VULHUB",
        "id": "VHN-123911"
      },
      {
        "db": "BID",
        "id": "105931"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-014527"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201811-488"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-13814"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "IVD",
        "id": "7d80ae62-463f-11e9-b905-000c29342cb1"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-25432"
      },
      {
        "db": "VULHUB",
        "id": "VHN-123911"
      },
      {
        "db": "BID",
        "id": "105931"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-014527"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201811-488"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-13814"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2018-12-14T00:00:00",
        "db": "IVD",
        "id": "7d80ae62-463f-11e9-b905-000c29342cb1"
      },
      {
        "date": "2018-12-14T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2018-25432"
      },
      {
        "date": "2018-12-13T00:00:00",
        "db": "VULHUB",
        "id": "VHN-123911"
      },
      {
        "date": "2018-11-13T00:00:00",
        "db": "BID",
        "id": "105931"
      },
      {
        "date": "2019-03-26T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-014527"
      },
      {
        "date": "2018-11-15T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201811-488"
      },
      {
        "date": "2018-12-13T16:29:00.350000",
        "db": "NVD",
        "id": "CVE-2018-13814"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2018-12-14T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2018-25432"
      },
      {
        "date": "2019-10-09T00:00:00",
        "db": "VULHUB",
        "id": "VHN-123911"
      },
      {
        "date": "2018-11-13T00:00:00",
        "db": "BID",
        "id": "105931"
      },
      {
        "date": "2019-03-26T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-014527"
      },
      {
        "date": "2019-10-17T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201811-488"
      },
      {
        "date": "2024-11-21T03:48:07.560000",
        "db": "NVD",
        "id": "CVE-2018-13814"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201811-488"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Siemens SIMATIC Panels and SIMATIC WinCC code injection vulnerability",
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-25432"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201811-488"
      }
    ],
    "trust": 1.2
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Input validation error",
    "sources": [
      {
        "db": "IVD",
        "id": "7d80ae62-463f-11e9-b905-000c29342cb1"
      },
      {
        "db": "BID",
        "id": "105931"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201811-488"
      }
    ],
    "trust": 1.1
  }
}

VAR-201904-0174

Vulnerability from variot - Updated: 2024-11-23 22:25

The webserver of the affected devices contains a vulnerability that may lead to a denial of service condition. An attacker may cause a denial of service situation which leads to a restart of the webserver of the affected device.

The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the device. Multiple Siemens products contain input validation vulnerabilities.Service operation interruption (DoS) There is a possibility of being put into a state. SiemensCP, SIAMTIC, SIMOCODE, SINAMICS, SITOP and TIM are all devices manufactured by Siemens. Multiple Siemens products are prone to an unspecified denial-of-service vulnerability. Attackers can exploit this issue to cause a denial-of-service condition, denying service to legitimate users. A vulnerability has been identified in CP1604, CP1616, SIMATIC CP343-1 Advanced, SIMATIC CP443-1, SIMATIC CP443-1 Advanced, SIMATIC CP443-1 OPC UA, SIMATIC ET 200 SP Open Controller CPU 1515SP PC, SIMATIC ET 200 SP Open Controller CPU 1515SP PC2, SIMATIC HMI Comfort Outdoor Panels 7" & 15", SIMATIC HMI Comfort Panels 4" - 22", SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F, SIMATIC IPC DiagMonitor, SIMATIC RF181-EIP, SIMATIC RF182C, SIMATIC RF185C, SIMATIC RF186C, SIMATIC RF188C, SIMATIC RF600R, SIMATIC S7-1500 CPU family, SIMATIC S7-1500 Software Controller, SIMATIC S7-300 CPU family, SIMATIC S7-400 PN (incl. F) V6 and below, SIMATIC S7-400 PN/DP V7 (incl. F), SIMATIC S7-PLCSIM Advanced, SIMATIC Teleservice Adapter IE Advanced, SIMATIC Teleservice Adapter IE Basic, SIMATIC Teleservice Adapter IE Standard, SIMATIC WinAC RTX (F) 2010, SIMATIC WinCC Runtime Advanced, SIMOCODE pro V EIP, SIMOCODE pro V PN, SINAMICS G130 V4.6 (Control Unit), SINAMICS G130 V4.7 (Control Unit), SINAMICS G130 V4.7 SP1 (Control Unit), SINAMICS G130 V4.8 (Control Unit), SINAMICS G130 V5.1 (Control Unit), SINAMICS G130 V5.1 SP1 (Control Unit), SINAMICS G150 V4.6 (Control Unit), SINAMICS G150 V4.7 (Control Unit), SINAMICS G150 V4.7 SP1 (Control Unit), SINAMICS G150 V4.8 (Control Unit), SINAMICS G150 V5.1 (Control Unit), SINAMICS G150 V5.1 SP1 (Control Unit), SINAMICS GH150 V4.7 (Control Unit), SINAMICS GH150 V4.8 (Control Unit), SINAMICS GL150 V4.7 (Control Unit), SINAMICS GL150 V4.8 (Control Unit), SINAMICS GM150 V4.7 (Control Unit), SINAMICS GM150 V4.8 (Control Unit), SINAMICS S120 V4.6 (Control Unit), SINAMICS S120 V4.7 (Control Unit), SINAMICS S120 V4.7 SP1 (Control Unit), SINAMICS S120 V4.8 (Control Unit), SINAMICS S120 V5.1 (Control Unit), SINAMICS S120 V5.1 SP1 (Control Unit), SINAMICS S150 V4.6 (Control Unit), SINAMICS S150 V4.7 (Control Unit), SINAMICS S150 V4.7 SP1 (Control Unit), SINAMICS S150 V4.8 (Control Unit), SINAMICS S150 V5.1 (Control Unit), SINAMICS S150 V5.1 SP1 (Control Unit), SINAMICS S210 V5.1 (Control Unit), SINAMICS S210 V5.1 SP1 (Control Unit), SINAMICS SL150 V4.7 (Control Unit), SINAMICS SL150 V4.8 (Control Unit), SINAMICS SM120 V4.7 (Control Unit), SINAMICS SM120 V4.8 (Control Unit), SINAMICS SM150 V4.8 (Control Unit), SITOP Manager, SITOP PSU8600, SITOP UPS1600, TIM 1531 IRC. At the time of advisory publication no public exploitation of this security vulnerability was known. Siemens SIMATIC S7-1500 CPU, etc. are all products of German Siemens (Siemens). SIMATIC S7-1500 CPU is a CPU (central processing unit) module. CP1616 is a communications processor. SIMATIC S7-1500 is a programmable logic controller. The vulnerability stems from the failure of the network system or product to properly validate the input data

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201904-0174",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "sinamics s210",
        "scope": "eq",
        "trust": 1.3,
        "vendor": "siemens",
        "version": "5.1"
      },
      {
        "model": "sinamics s150",
        "scope": "eq",
        "trust": 1.3,
        "vendor": "siemens",
        "version": "5.1"
      },
      {
        "model": "simatic hmi comfort outdoor panels",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "simatic hmi ktp mobile panels ktp900f",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "simatic hmi ktp mobile panels ktp700f",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "sinamics sm120",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.8"
      },
      {
        "model": "simatic s7-plcsim advanced",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.0"
      },
      {
        "model": "simatic ipc diagmonitor",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.1.3"
      },
      {
        "model": "simatic s7-1500s",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.6.1"
      },
      {
        "model": "sinamics gh150",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.8"
      },
      {
        "model": "simatic hmi ktp mobile panels ktp900",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "simatic wincc runtime advanced",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "sinamics gl150",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.8"
      },
      {
        "model": "simatic s7-400 pn",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simocode pro v pn",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.1.3"
      },
      {
        "model": "sinamics gm150",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.8"
      },
      {
        "model": "simatic hmi ktp mobile panels ktp700",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "simatic s7-1500",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.6.1"
      },
      {
        "model": "simatic cp443-1 advanced",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "sinamics sl150",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.8"
      },
      {
        "model": "sitop manager",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "1.1"
      },
      {
        "model": "sinamics sm120",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.8"
      },
      {
        "model": "simatic hmi comfort panels",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "simatic hmi ktp mobile panels ktp400f",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "simatic et 200 sp open controller cpu 1515sp pc2",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.7"
      },
      {
        "model": "sinamics g130",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2"
      },
      {
        "model": "cp1604",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic winac rtx",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2010"
      },
      {
        "model": "sinamics s120",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2"
      },
      {
        "model": "sitop psu8600",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "1.5"
      },
      {
        "model": "simatic hmi ktp mobile panels ktp700f",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "simatic cp443-1",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simocode pro v eip",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "1.1.3"
      },
      {
        "model": "simatic s7-plcsim advanced",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.0"
      },
      {
        "model": "simatic s7-400 pn\\/dp",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "sitop ups1600",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.3"
      },
      {
        "model": "simatic s7-1500 software controller",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.7"
      },
      {
        "model": "sinamics sm150",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.1"
      },
      {
        "model": "simatic rf182c",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic rf600r",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "3.2.1"
      },
      {
        "model": "cp1616",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic teleservice adapter ie standard",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic rf185c",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "1.1.0"
      },
      {
        "model": "simatic rf186c",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "1.1.0"
      },
      {
        "model": "simatic hmi comfort outdoor panels",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "simatic teleservice adapter ie basic",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic hmi ktp mobile panels ktp900f",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "sinamics gm150",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.8"
      },
      {
        "model": "simatic s7-1500t",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.6.1"
      },
      {
        "model": "simatic hmi ktp mobile panels ktp700",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "simatic hmi ktp mobile panels ktp900",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "simatic s7-300",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "3.3.17"
      },
      {
        "model": "simatic wincc runtime advanced",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "sinamics gh150",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.8"
      },
      {
        "model": "simatic rf188c",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "1.1.0"
      },
      {
        "model": "simatic hmi ktp mobile panels ktp400f",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "sinamics gl150",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.8"
      },
      {
        "model": "simatic et 200 sp open controller cpu 1515sp pc",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.1.6"
      },
      {
        "model": "sinamics g150",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.2"
      },
      {
        "model": "sinamics s150",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.1"
      },
      {
        "model": "simatic winac rtx",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2010"
      },
      {
        "model": "sinamics sl150",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "4.8"
      },
      {
        "model": "simatic cp443-1 opc ua",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "sinamics sm150",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.1"
      },
      {
        "model": "simatic hmi comfort panels",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "simatic rf181-eip",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "tim 1531 irc",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.1"
      },
      {
        "model": "simatic s7-1500f",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2.6.1"
      },
      {
        "model": "simatic cp343-1 advanced",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "sinamics s210",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.1"
      },
      {
        "model": "simatic teleservice adapter ie advanced",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic cp 1543sp-1",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic cp 1604",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic cp 1616",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic cp 343-1 advanced",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic cp 443-1 adv",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic cp 443-1",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic et 200 sp open controller cpu 1515sp pc",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic et 200 sp open controller cpu 1515sp pc2",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic hmi comfort outdoor panels",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic hmi comfort panels",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic rf185c",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.6,
        "vendor": "sinamics s150",
        "version": "5.1"
      },
      {
        "model": "simatic winac rtx sp2 all",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "2010"
      },
      {
        "model": "simatic s7-300 cpu family all",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic s7-400 pn/dp",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v7"
      },
      {
        "model": "simatic s7-1500 software controller",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinamics s120",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinamics g130 and g150",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic rf182c",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic wincc runtime advanced",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic cp443-1 opc ua",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic ipc diagmonitor",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic rf188c",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic rf600r",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "cp1604",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "cp1616",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic et sp open controller cpu 1515sp pc",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "200\u003cv2.1.6"
      },
      {
        "model": "simatic hmi comfort panels 4\" 22\"",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic hmi ktp mobile panels",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic s7-1500 cpu family",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic s7-400 pn",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v6"
      },
      {
        "model": "sinamics s150",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sinamics s210",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v5.1"
      },
      {
        "model": "sinamics s210 sp1",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v5.1"
      },
      {
        "model": "tim irc",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "1531"
      },
      {
        "model": "simatic hmi comfort outdoor panels 7\" \u0026 15\"",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic rf181-eip",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic rf186c",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic s7-plcsim advanced",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic teleservice adapter ie advanced",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic teleservice adapter ie basic",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic teleservice adapter ie standard",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simocode pro eip",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v"
      },
      {
        "model": "simocode pro pn",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v"
      },
      {
        "model": "sitop manager",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sitop psu8600",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "sitop ups1600",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "siamtic rf185c",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic cp343-1 advanced",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic cp443-1",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic cp443-1 advanced",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic et sp open controller cpu 1515sp pc2",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "200"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.4,
        "vendor": "sinamics s210",
        "version": "5.1"
      },
      {
        "model": "tim irc",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "15310"
      },
      {
        "model": "sitop ups1600",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "sitop psu8600",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "sitop manager",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "sinamics s210 sp1",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "5.1"
      },
      {
        "model": "sinamics s150 sp1",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "5.1"
      },
      {
        "model": "sinamics s150",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.8"
      },
      {
        "model": "sinamics s150 sp1",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "sinamics s150",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "sinamics s150",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.6"
      },
      {
        "model": "sinamics s120 sp1",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "5.1"
      },
      {
        "model": "sinamics s120",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "5.1"
      },
      {
        "model": "sinamics s120",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.8"
      },
      {
        "model": "sinamics s120 sp1",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "sinamics s120",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "sinamics s120",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.6"
      },
      {
        "model": "sinamics g150 sp1",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "5.1"
      },
      {
        "model": "sinamics g150",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "5.1"
      },
      {
        "model": "sinamics g150",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.8"
      },
      {
        "model": "sinamics g150 sp1",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "sinamics g150",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "sinamics g150",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.6"
      },
      {
        "model": "sinamics g130 sp1",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "5.1"
      },
      {
        "model": "sinamics g130",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "5.1"
      },
      {
        "model": "sinamics g130",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.8"
      },
      {
        "model": "sinamics g130 sp1",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "sinamics g130",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.7"
      },
      {
        "model": "sinamics g130",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.6"
      },
      {
        "model": "simocode pro pn",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "v0"
      },
      {
        "model": "simocode pro eip",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "v0"
      },
      {
        "model": "simatic wincc runtime advanced",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic winac rtx",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "20100"
      },
      {
        "model": "simatic teleservice adapter ie standard",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic teleservice adapter ie basic",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic teleservice adapter ie advanced",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic s7-plcsim advanced",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic s7-400 pn/dp",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "7"
      },
      {
        "model": "simatic s7-400 pn",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "v60"
      },
      {
        "model": "simatic s7-300 cpu",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic s7-1500 software controller",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic s7-1500 cpu",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic rf600r",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic rf188c",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic rf186c",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic rf185c",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic rf182c",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic ipc diagmonitor",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic hmi ktp900f mobile",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic hmi ktp900 mobile",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic hmi ktp700f mobile",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic hmi ktp700 mobile",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic hmi ktp400f mobile",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic hmi ktp mobile panels",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic hmi comfort panels",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic hmi comfort outdoor panels",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic et200 open controller cpu 1515sp pc2",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic et200 open controller cpu 1515sp pc",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic cp opc ua",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "443-10"
      },
      {
        "model": "simatic cp advanced",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "443-10"
      },
      {
        "model": "simatic cp",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "443-10"
      },
      {
        "model": "simatic cp advanced",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "343-10"
      },
      {
        "model": "rfid 181-eip",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "cp",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "16160"
      },
      {
        "model": "cp",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "16040"
      },
      {
        "model": "sinamics s150 sp1 hf4",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "5.1"
      },
      {
        "model": "sinamics s150 hf6",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.8"
      },
      {
        "model": "sinamics s120 sp1 hf4",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "5.1"
      },
      {
        "model": "sinamics s120 hf6",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.8"
      },
      {
        "model": "sinamics g150 sp1 hf4",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "5.1"
      },
      {
        "model": "sinamics g150 hf6",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.8"
      },
      {
        "model": "sinamics g130 sp1 hf4",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "5.1"
      },
      {
        "model": "sinamics g130 hf6",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4.8"
      },
      {
        "model": "simatic s7-300 cpu",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "v3.x.16"
      },
      {
        "model": "simatic et200 open controller cpu 1515sp pc",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "2.1.6"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "cp1604",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic hmi comfort panels",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic hmi ktp mobile panels ktp400f",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic hmi ktp mobile panels ktp700",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic hmi ktp mobile panels ktp700f",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic hmi ktp mobile panels ktp900",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic hmi ktp mobile panels ktp900f",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic cp443 1 opc ua",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic ipc diagmonitor",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic s7 1500 controller",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic s7 plcsim advanced",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic wincc runtime advanced",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sitop manager",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic rf600r",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic rf188c",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic rf186c",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "cp1616",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic rf182c",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic rf181 eip",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic s7 1500",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic s7 300",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic s7 400 pn",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic s7 400 pn dp",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic teleservice adapter ie advanced",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic teleservice adapter ie basic",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic teleservice adapter ie standard",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic winac rtx 2010",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic rf185c",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simocode pro v eip",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simocode pro v pn",
        "version": null
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sinamics g130",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sinamics g150",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sinamics s120",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sinamics s150",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sinamics s210",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sitop psu8600",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "sitop ups1600",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "tim 1531 irc",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic cp343 1 advanced",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic s7 1500f",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic s7 1500s",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic s7 1500t",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic cp443 1",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic cp443 1 advanced",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic et 200 sp open controller cpu 1515sp pc",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic et 200 sp open controller cpu 1515sp pc2",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic hmi comfort outdoor panels",
        "version": "*"
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "a397cc8b-ee17-4faf-8447-e9ee5f57dd12"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-12904"
      },
      {
        "db": "BID",
        "id": "107842"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-003541"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-6568"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_cp_1604_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_cp_1616_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_cp343-1_advanced_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_cp_443-1_adv_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_cp_443-1_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_et_200_sp_open_controller_cpu_1515sp_pc_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_et_200_sp_open_controller_cpu_1515sp_pc2_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_hmi_comfort_outdoor_panels_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_hmi_comfort_panels",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_rf185c_firmware",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-003541"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Siemens reported this vulnerability to NCCIC.",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201904-458"
      }
    ],
    "trust": 0.6
  },
  "cve": "CVE-2019-6568",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "PARTIAL",
            "baseScore": 5.0,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "CVE-2019-6568",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 1.8,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 5.0,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2019-12904",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "IVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 5.0,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "a397cc8b-ee17-4faf-8447-e9ee5f57dd12",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 0.2,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
            "version": "2.9 [IVD]"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "PARTIAL",
            "baseScore": 5.0,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "VHN-158003",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 0.1,
            "vectorString": "AV:N/AC:L/AU:N/C:N/I:N/A:P",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 3.9,
            "id": "CVE-2019-6568",
            "impactScore": 3.6,
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 2.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 7.5,
            "baseSeverity": "High",
            "confidentialityImpact": "None",
            "exploitabilityScore": null,
            "id": "CVE-2019-6568",
            "impactScore": null,
            "integrityImpact": "None",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2019-6568",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "productcert@siemens.com",
            "id": "CVE-2019-6568",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "NVD",
            "id": "CVE-2019-6568",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2019-12904",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201904-458",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "IVD",
            "id": "a397cc8b-ee17-4faf-8447-e9ee5f57dd12",
            "trust": 0.2,
            "value": "HIGH"
          },
          {
            "author": "VULHUB",
            "id": "VHN-158003",
            "trust": 0.1,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "a397cc8b-ee17-4faf-8447-e9ee5f57dd12"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-12904"
      },
      {
        "db": "VULHUB",
        "id": "VHN-158003"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-003541"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201904-458"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-6568"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-6568"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "The webserver of the affected devices contains a vulnerability that may lead to\r\na denial of service condition. An attacker may cause a denial of service\r\nsituation which leads to a restart of the webserver of the affected device. \r\n\r\nThe security vulnerability could be exploited by an attacker with network\r\naccess to the affected systems. Successful exploitation requires no system\r\nprivileges and no user interaction. An attacker could use the vulnerability\r\nto compromise availability of the device. Multiple Siemens products contain input validation vulnerabilities.Service operation interruption (DoS) There is a possibility of being put into a state. SiemensCP, SIAMTIC, SIMOCODE, SINAMICS, SITOP and TIM are all devices manufactured by Siemens. Multiple Siemens products are prone to an unspecified denial-of-service vulnerability. \nAttackers can exploit this issue to cause a denial-of-service condition, denying service to legitimate users. A vulnerability has been identified in CP1604, CP1616, SIMATIC CP343-1 Advanced, SIMATIC CP443-1, SIMATIC CP443-1 Advanced, SIMATIC CP443-1 OPC UA, SIMATIC ET 200 SP Open Controller CPU 1515SP PC, SIMATIC ET 200 SP Open Controller CPU 1515SP PC2, SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\", SIMATIC HMI Comfort Panels 4\" - 22\", SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F, SIMATIC IPC DiagMonitor, SIMATIC RF181-EIP, SIMATIC RF182C, SIMATIC RF185C, SIMATIC RF186C, SIMATIC RF188C, SIMATIC RF600R, SIMATIC S7-1500 CPU family, SIMATIC S7-1500 Software Controller, SIMATIC S7-300 CPU family, SIMATIC S7-400 PN (incl. F) V6 and below, SIMATIC S7-400 PN/DP V7 (incl. F), SIMATIC S7-PLCSIM Advanced, SIMATIC Teleservice Adapter IE Advanced, SIMATIC Teleservice Adapter IE Basic, SIMATIC Teleservice Adapter IE Standard, SIMATIC WinAC RTX (F) 2010, SIMATIC WinCC Runtime Advanced, SIMOCODE pro V EIP, SIMOCODE pro V PN, SINAMICS G130 V4.6 (Control Unit), SINAMICS G130 V4.7 (Control Unit), SINAMICS G130 V4.7 SP1 (Control Unit), SINAMICS G130 V4.8 (Control Unit), SINAMICS G130 V5.1 (Control Unit), SINAMICS G130 V5.1 SP1 (Control Unit), SINAMICS G150 V4.6 (Control Unit), SINAMICS G150 V4.7 (Control Unit), SINAMICS G150 V4.7 SP1 (Control Unit), SINAMICS G150 V4.8 (Control Unit), SINAMICS G150 V5.1 (Control Unit), SINAMICS G150 V5.1 SP1 (Control Unit), SINAMICS GH150 V4.7 (Control Unit), SINAMICS GH150 V4.8 (Control Unit), SINAMICS GL150 V4.7 (Control Unit), SINAMICS GL150 V4.8 (Control Unit), SINAMICS GM150 V4.7 (Control Unit), SINAMICS GM150 V4.8 (Control Unit), SINAMICS S120 V4.6 (Control Unit), SINAMICS S120 V4.7 (Control Unit), SINAMICS S120 V4.7 SP1 (Control Unit), SINAMICS S120 V4.8 (Control Unit), SINAMICS S120 V5.1 (Control Unit), SINAMICS S120 V5.1 SP1 (Control Unit), SINAMICS S150 V4.6 (Control Unit), SINAMICS S150 V4.7 (Control Unit), SINAMICS S150 V4.7 SP1 (Control Unit), SINAMICS S150 V4.8 (Control Unit), SINAMICS S150 V5.1 (Control Unit), SINAMICS S150 V5.1 SP1 (Control Unit), SINAMICS S210 V5.1 (Control Unit), SINAMICS S210 V5.1 SP1 (Control Unit), SINAMICS SL150 V4.7 (Control Unit), SINAMICS SL150 V4.8 (Control Unit), SINAMICS SM120 V4.7 (Control Unit), SINAMICS SM120 V4.8 (Control Unit), SINAMICS SM150 V4.8 (Control Unit), SITOP Manager, SITOP PSU8600, SITOP UPS1600, TIM 1531 IRC. At the time of advisory publication no public exploitation of this security vulnerability was known. Siemens SIMATIC S7-1500 CPU, etc. are all products of German Siemens (Siemens). SIMATIC S7-1500 CPU is a CPU (central processing unit) module. CP1616 is a communications processor. SIMATIC S7-1500 is a programmable logic controller. The vulnerability stems from the failure of the network system or product to properly validate the input data",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2019-6568"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-003541"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-12904"
      },
      {
        "db": "BID",
        "id": "107842"
      },
      {
        "db": "IVD",
        "id": "a397cc8b-ee17-4faf-8447-e9ee5f57dd12"
      },
      {
        "db": "VULHUB",
        "id": "VHN-158003"
      }
    ],
    "trust": 2.7
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2019-6568",
        "trust": 3.6
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-19-099-06",
        "trust": 2.3
      },
      {
        "db": "SIEMENS",
        "id": "SSA-480230",
        "trust": 2.0
      },
      {
        "db": "SIEMENS",
        "id": "SSA-530931",
        "trust": 1.7
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-19-227-04",
        "trust": 1.4
      },
      {
        "db": "BID",
        "id": "107842",
        "trust": 1.0
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201904-458",
        "trust": 0.9
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-12904",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-003541",
        "trust": 0.8
      },
      {
        "db": "AUSCERT",
        "id": "ESB-2019.3150",
        "trust": 0.6
      },
      {
        "db": "AUSCERT",
        "id": "ESB-2019.1204.2",
        "trust": 0.6
      },
      {
        "db": "IVD",
        "id": "A397CC8B-EE17-4FAF-8447-E9EE5F57DD12",
        "trust": 0.2
      },
      {
        "db": "VULHUB",
        "id": "VHN-158003",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "a397cc8b-ee17-4faf-8447-e9ee5f57dd12"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-12904"
      },
      {
        "db": "VULHUB",
        "id": "VHN-158003"
      },
      {
        "db": "BID",
        "id": "107842"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-003541"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201904-458"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-6568"
      }
    ]
  },
  "id": "VAR-201904-0174",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "IVD",
        "id": "a397cc8b-ee17-4faf-8447-e9ee5f57dd12"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-12904"
      },
      {
        "db": "VULHUB",
        "id": "VHN-158003"
      }
    ],
    "trust": 1.5998432480392157
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS",
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      },
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.2
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "a397cc8b-ee17-4faf-8447-e9ee5f57dd12"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-12904"
      }
    ]
  },
  "last_update_date": "2024-11-23T22:25:58.024000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "SSA-480230",
        "trust": 0.8,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-480230.pdf"
      },
      {
        "title": "SSA-530931",
        "trust": 0.8,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-530931.pdf"
      },
      {
        "title": "Patches for multiple Siemens product denial of service vulnerabilities",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/160237"
      },
      {
        "title": "Multiple Siemens Product security vulnerabilities",
        "trust": 0.6,
        "url": "http://123.124.177.30/web/xxk/bdxqById.tag?id=91286"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-12904"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-003541"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201904-458"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-125",
        "trust": 1.1
      },
      {
        "problemtype": "CWE-20",
        "trust": 0.9
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-158003"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-003541"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-6568"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.3,
        "url": "https://ics-cert.us-cert.gov/advisories/icsa-19-099-06"
      },
      {
        "trust": 2.0,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-480230.pdf"
      },
      {
        "trust": 1.7,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-530931.pdf"
      },
      {
        "trust": 1.4,
        "url": "https://www.us-cert.gov/ics/advisories/icsa-19-227-04"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2019-6568"
      },
      {
        "trust": 0.9,
        "url": "http://subscriber.communications.siemens.com/"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-6568"
      },
      {
        "trust": 0.6,
        "url": "https://www.auscert.org.au/bulletins/esb-2019.3150/"
      },
      {
        "trust": 0.6,
        "url": "https://www.us-cert.gov/ics/advisories/icsa-19-099-06"
      },
      {
        "trust": 0.6,
        "url": "https://us-cert.cisa.gov/ics/advisories/icsa-19-099-06"
      },
      {
        "trust": 0.6,
        "url": "https://www.securityfocus.com/bid/107842"
      },
      {
        "trust": 0.6,
        "url": "https://vigilance.fr/vulnerability/siemens-simatic-denial-of-service-via-webserver-28976"
      },
      {
        "trust": 0.6,
        "url": "https://www.auscert.org.au/bulletins/78710"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2019-12904"
      },
      {
        "db": "VULHUB",
        "id": "VHN-158003"
      },
      {
        "db": "BID",
        "id": "107842"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-003541"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201904-458"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-6568"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "IVD",
        "id": "a397cc8b-ee17-4faf-8447-e9ee5f57dd12"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2019-12904"
      },
      {
        "db": "VULHUB",
        "id": "VHN-158003"
      },
      {
        "db": "BID",
        "id": "107842"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-003541"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201904-458"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-6568"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2019-05-05T00:00:00",
        "db": "IVD",
        "id": "a397cc8b-ee17-4faf-8447-e9ee5f57dd12"
      },
      {
        "date": "2019-05-05T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2019-12904"
      },
      {
        "date": "2019-04-17T00:00:00",
        "db": "VULHUB",
        "id": "VHN-158003"
      },
      {
        "date": "2019-04-09T00:00:00",
        "db": "BID",
        "id": "107842"
      },
      {
        "date": "2019-05-20T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2019-003541"
      },
      {
        "date": "2019-04-09T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201904-458"
      },
      {
        "date": "2019-04-17T14:29:03.683000",
        "db": "NVD",
        "id": "CVE-2019-6568"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2019-05-07T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2019-12904"
      },
      {
        "date": "2023-01-10T00:00:00",
        "db": "VULHUB",
        "id": "VHN-158003"
      },
      {
        "date": "2019-04-09T00:00:00",
        "db": "BID",
        "id": "107842"
      },
      {
        "date": "2019-08-20T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2019-003541"
      },
      {
        "date": "2023-04-12T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201904-458"
      },
      {
        "date": "2024-11-21T04:46:42.773000",
        "db": "NVD",
        "id": "CVE-2019-6568"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201904-458"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Vulnerability related to input validation in multiple Siemens products",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-003541"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "buffer error",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201904-458"
      }
    ],
    "trust": 0.6
  }
}

VAR-201812-0343

Vulnerability from variot - Updated: 2024-11-23 22:17

A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15 Update 4), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15 Update 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15 Update 4), SIMATIC WinCC Runtime Advanced (All versions < V15 Update 4), SIMATIC WinCC Runtime Professional (All versions < V15 Update 4), SIMATIC WinCC (TIA Portal) (All versions < V15 Update 4), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). A directory traversal vulnerability could allow to download arbitrary files from the device. The security vulnerability could be exploited by an attacker with network access to the integrated web server. No user interaction and no authentication is required to exploit the vulnerability. The vulnerability impacts the confidentiality of the device. At the time of advisory publication no public exploitation of this security vulnerability was known. plural SIMATIC The product contains a path traversal vulnerability.Information may be obtained. Siemens SIMATIC Panels is prone to following security vulnerabilities: 1. An open-redirection vulnerability 2. A directory-traversal vulnerability Remote attackers may use a specially crafted request with directory-traversal sequences ('../') to retrieve arbitrary files from the affected system in the context of the application or by constructing a crafted URI and enticing a user to follow it and when an unsuspecting victim follows the link, they may be redirected to an attacker-controlled site. are all HMI software used by Siemens in Germany to control and monitor machines and equipment

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201812-0343",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "simatic wincc runtime",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.0"
      },
      {
        "model": "simatic hmi ktp mobile panels ktp700f",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.0"
      },
      {
        "model": "simatic hmi mp",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic hmi op",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic hmi comfort panels",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.0"
      },
      {
        "model": "simatic hmi ktp mobile panels ktp400f",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.0"
      },
      {
        "model": "simatic hmi comfort outdoor panels",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.0"
      },
      {
        "model": "simatic hmi ktp mobile panels ktp700",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.0"
      },
      {
        "model": "simatic wincc \\",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.0"
      },
      {
        "model": "simatic hmi tp",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic hmi ktp mobile panels ktp900f",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.0"
      },
      {
        "model": "simatic hmi ktp mobile panels ktp900",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.0"
      },
      {
        "model": "simatic hmi comfort outdoor panels",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic hmi comfort panels",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic hmi ktp mobile panels ktp400f",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic hmi ktp mobile panels ktp700",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic hmi ktp mobile panels ktp700f",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic hmi ktp mobile panels ktp900",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic hmi ktp mobile panels ktp900f",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic wincc",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic wincc runtime advanced",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic wincc runtime professional",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic wincc runtime professional",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "15"
      },
      {
        "model": "simatic wincc runtime professional sp1",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "14"
      },
      {
        "model": "simatic wincc runtime professional",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "14"
      },
      {
        "model": "simatic wincc runtime professional sp2",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "13"
      },
      {
        "model": "simatic wincc runtime professional sp1 upd2",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "13"
      },
      {
        "model": "simatic wincc runtime professional sp update",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "1319"
      },
      {
        "model": "simatic wincc runtime professional",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "13"
      },
      {
        "model": "simatic wincc runtime advanced",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "15"
      },
      {
        "model": "simatic wincc runtime advanced sp1 upd2",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "13"
      },
      {
        "model": "simatic wincc runtime advanced",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "13"
      },
      {
        "model": "simatic wincc runtime advanced sp1 upd5",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "12"
      },
      {
        "model": "simatic wincc runtime advanced",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "12"
      },
      {
        "model": "simatic wincc runtime advanced",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic wincc update",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "v135"
      },
      {
        "model": "simatic wincc sp1",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "v12"
      },
      {
        "model": "simatic wincc",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "v120"
      },
      {
        "model": "simatic wincc",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "v110"
      },
      {
        "model": "simatic wincc",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "v15"
      },
      {
        "model": "simatic wincc update",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "v136"
      },
      {
        "model": "simatic wincc sp1",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "v13"
      },
      {
        "model": "simatic wincc",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "v13"
      },
      {
        "model": "simatic wincc",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "v10"
      },
      {
        "model": "simatic hmi ktp mobile panels",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic hmi comfort panels",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4"
      },
      {
        "model": "simatic hmi comfort panels",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "22"
      },
      {
        "model": "simatic hmi comfort panels",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "15"
      },
      {
        "model": "simatic hmi comfort panels sp1 upd2",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "13"
      },
      {
        "model": "simatic hmi comfort panels",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "13"
      },
      {
        "model": "simatic hmi comfort panels sp1 upd5",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "12"
      },
      {
        "model": "simatic hmi comfort panels",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "12"
      },
      {
        "model": "simatic hmi comfort panels",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic hmi comfort outdoor panels",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic hmi classic devices",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic wincc runtime professional update",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "154"
      },
      {
        "model": "simatic wincc runtime advanced update",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "154"
      },
      {
        "model": "simatic wincc update",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "154"
      },
      {
        "model": "simatic hmi ktp mobile panels update",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "154"
      },
      {
        "model": "simatic hmi comfort panels update",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "154"
      },
      {
        "model": "simatic hmi comfort outdoor panels update",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "154"
      }
    ],
    "sources": [
      {
        "db": "BID",
        "id": "105922"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-014525"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-13812"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_hmi_comfort_outdoor_panels_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_hmi_comfort_panels",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/a:siemens:simatic_wincc_%28tia_portal%29",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/a:siemens:wincc_runtime_advanced",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/a:siemens:simatic_wincc_runtime_professional",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-014525"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Hosni Tounsi from Carthage Red Team",
    "sources": [
      {
        "db": "BID",
        "id": "105922"
      }
    ],
    "trust": 0.3
  },
  "cve": "CVE-2018-13812",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "NONE",
            "baseScore": 5.0,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CVE-2018-13812",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 1.8,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "NONE",
            "baseScore": 5.0,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "VHN-123909",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 0.1,
            "vectorString": "AV:N/AC:L/AU:N/C:P/I:N/A:N",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "NONE",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2018-13812",
            "impactScore": 3.6,
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.8,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2018-13812",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "NVD",
            "id": "CVE-2018-13812",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201811-482",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "VULHUB",
            "id": "VHN-123909",
            "trust": 0.1,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-123909"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-014525"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201811-482"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-13812"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A vulnerability has been identified in SIMATIC HMI Comfort Panels 4\" - 22\" (All versions \u003c V15 Update 4), SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (All versions \u003c V15 Update 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15 Update 4), SIMATIC WinCC Runtime Advanced (All versions \u003c V15 Update 4), SIMATIC WinCC Runtime Professional (All versions \u003c V15 Update 4), SIMATIC WinCC (TIA Portal) (All versions \u003c V15 Update 4), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). A directory traversal vulnerability could allow to download arbitrary files from the device. The security vulnerability could be exploited by an attacker with network access to the integrated web server. No user interaction and no authentication is required to exploit the vulnerability. The vulnerability impacts the confidentiality of the device. At the time of advisory publication no public exploitation of this security vulnerability was known. plural SIMATIC The product contains a path traversal vulnerability.Information may be obtained. Siemens SIMATIC Panels is prone to following security vulnerabilities:\n1. An open-redirection vulnerability\n2. A directory-traversal vulnerability\nRemote attackers may use a specially crafted request with  directory-traversal sequences (\u0027../\u0027) to retrieve arbitrary files from  the affected system in the context of the application or by constructing a crafted URI and enticing a user to follow it and when an unsuspecting victim follows the link, they may be redirected to an attacker-controlled site. are all HMI software used by Siemens in Germany to control and monitor machines and equipment",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2018-13812"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-014525"
      },
      {
        "db": "BID",
        "id": "105922"
      },
      {
        "db": "VULHUB",
        "id": "VHN-123909"
      }
    ],
    "trust": 1.98
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2018-13812",
        "trust": 2.8
      },
      {
        "db": "BID",
        "id": "105922",
        "trust": 2.0
      },
      {
        "db": "SIEMENS",
        "id": "SSA-233109",
        "trust": 1.7
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-18-317-08",
        "trust": 1.7
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-014525",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201811-482",
        "trust": 0.7
      },
      {
        "db": "VULHUB",
        "id": "VHN-123909",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-123909"
      },
      {
        "db": "BID",
        "id": "105922"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-014525"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201811-482"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-13812"
      }
    ]
  },
  "id": "VAR-201812-0343",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-123909"
      }
    ],
    "trust": 0.7828699085714284
  },
  "last_update_date": "2024-11-23T22:17:14.886000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "SSA-233109",
        "trust": 0.8,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-233109.pdf"
      },
      {
        "title": "Multiple Siemens Product path traversal vulnerability fixes",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=86883"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-014525"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201811-482"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-22",
        "trust": 1.9
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-123909"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-014525"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-13812"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 1.7,
        "url": "http://www.securityfocus.com/bid/105922"
      },
      {
        "trust": 1.7,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-233109.pdf"
      },
      {
        "trust": 1.7,
        "url": "https://ics-cert.us-cert.gov/advisories/icsa-18-317-08"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-13812"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2018-13812"
      },
      {
        "trust": 0.3,
        "url": "http://subscriber.communications.siemens.com/"
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-123909"
      },
      {
        "db": "BID",
        "id": "105922"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-014525"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201811-482"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-13812"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "VULHUB",
        "id": "VHN-123909"
      },
      {
        "db": "BID",
        "id": "105922"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-014525"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201811-482"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-13812"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2018-12-13T00:00:00",
        "db": "VULHUB",
        "id": "VHN-123909"
      },
      {
        "date": "2018-11-14T00:00:00",
        "db": "BID",
        "id": "105922"
      },
      {
        "date": "2019-03-26T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-014525"
      },
      {
        "date": "2018-11-15T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201811-482"
      },
      {
        "date": "2018-12-13T16:29:00.290000",
        "db": "NVD",
        "id": "CVE-2018-13812"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2019-10-09T00:00:00",
        "db": "VULHUB",
        "id": "VHN-123909"
      },
      {
        "date": "2018-11-14T00:00:00",
        "db": "BID",
        "id": "105922"
      },
      {
        "date": "2019-03-26T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-014525"
      },
      {
        "date": "2019-10-17T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201811-482"
      },
      {
        "date": "2024-11-21T03:48:07.190000",
        "db": "NVD",
        "id": "CVE-2018-13812"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201811-482"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "plural  SIMATIC Path traversal vulnerability in products",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-014525"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "path traversal",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201811-482"
      }
    ],
    "trust": 0.6
  }
}

VAR-201812-0344

Vulnerability from variot - Updated: 2024-11-23 22:17

A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15 Update 4), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15 Update 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15 Update 4), SIMATIC WinCC Runtime Advanced (All versions < V15 Update 4), SIMATIC WinCC Runtime Professional (All versions < V15 Update 4), SIMATIC WinCC (TIA Portal) (All versions < V15 Update 4), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The webserver of affected HMI devices may allow URL redirections to untrusted websites. An attacker must trick a valid user who is authenticated to the device into clicking on a malicious link to exploit the vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known. plural SIMATIC The product contains an open redirect vulnerability.Information may be obtained and information may be altered. Siemens SIMATIC HMI Comfort Panels are all Germany's Siemens (Siemens) company HMI software for control and monitoring of machines and equipment.

The webserver in several Siemens products has an open redirection vulnerability. Siemens SIMATIC Panels is prone to following security vulnerabilities: 1. An open-redirection vulnerability 2. A directory-traversal vulnerability Remote attackers may use a specially crafted request with directory-traversal sequences ('../') to retrieve arbitrary files from the affected system in the context of the application or by constructing a crafted URI and enticing a user to follow it and when an unsuspecting victim follows the link, they may be redirected to an attacker-controlled site

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201812-0344",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "simatic wincc runtime",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.0"
      },
      {
        "model": "simatic hmi ktp mobile panels ktp700f",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.0"
      },
      {
        "model": "simatic hmi mp",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic hmi op",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic hmi comfort panels",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.0"
      },
      {
        "model": "simatic hmi ktp mobile panels ktp400f",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.0"
      },
      {
        "model": "simatic hmi comfort outdoor panels",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.0"
      },
      {
        "model": "simatic hmi ktp mobile panels ktp700",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.0"
      },
      {
        "model": "simatic wincc \\",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.0"
      },
      {
        "model": "simatic hmi tp",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic hmi ktp mobile panels ktp900f",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.0"
      },
      {
        "model": "simatic hmi ktp mobile panels ktp900",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.0"
      },
      {
        "model": "simatic hmi comfort outdoor panels",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic hmi comfort panels",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic hmi ktp mobile panels ktp400f",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic hmi ktp mobile panels ktp700",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic hmi ktp mobile panels ktp700f",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic hmi ktp mobile panels ktp900",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic hmi ktp mobile panels ktp900f",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic wincc",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic wincc runtime advanced",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic wincc runtime professional",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic hmi classic devices",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic hmi comfort outdoor panels 7\" \u0026 15\" update",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "154"
      },
      {
        "model": "simatic hmi comfort panels 4\"-22\" update",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "154"
      },
      {
        "model": "simatic hmi ktp mobile panels update",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "154"
      },
      {
        "model": "simatic wincc update",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "154"
      },
      {
        "model": "simatic wincc runtime advanced update",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "154"
      },
      {
        "model": "simatic wincc runtime professional update",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "154"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.4,
        "vendor": "simatic wincc runtime",
        "version": "*"
      },
      {
        "model": "simatic wincc runtime professional",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "15"
      },
      {
        "model": "simatic wincc runtime professional sp1",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "14"
      },
      {
        "model": "simatic wincc runtime professional",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "14"
      },
      {
        "model": "simatic wincc runtime professional sp2",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "13"
      },
      {
        "model": "simatic wincc runtime professional sp1 upd2",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "13"
      },
      {
        "model": "simatic wincc runtime professional sp update",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "1319"
      },
      {
        "model": "simatic wincc runtime professional",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "13"
      },
      {
        "model": "simatic wincc runtime advanced",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "15"
      },
      {
        "model": "simatic wincc runtime advanced sp1 upd2",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "13"
      },
      {
        "model": "simatic wincc runtime advanced",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "13"
      },
      {
        "model": "simatic wincc runtime advanced sp1 upd5",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "12"
      },
      {
        "model": "simatic wincc runtime advanced",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "12"
      },
      {
        "model": "simatic wincc runtime advanced",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic wincc update",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "v135"
      },
      {
        "model": "simatic wincc sp1",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "v12"
      },
      {
        "model": "simatic wincc",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "v120"
      },
      {
        "model": "simatic wincc",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "v110"
      },
      {
        "model": "simatic wincc",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "v15"
      },
      {
        "model": "simatic wincc update",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "v136"
      },
      {
        "model": "simatic wincc sp1",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "v13"
      },
      {
        "model": "simatic wincc",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "v13"
      },
      {
        "model": "simatic wincc",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "v10"
      },
      {
        "model": "simatic hmi ktp mobile panels",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic hmi comfort panels",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "4"
      },
      {
        "model": "simatic hmi comfort panels",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "22"
      },
      {
        "model": "simatic hmi comfort panels",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "15"
      },
      {
        "model": "simatic hmi comfort panels sp1 upd2",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "13"
      },
      {
        "model": "simatic hmi comfort panels",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "13"
      },
      {
        "model": "simatic hmi comfort panels sp1 upd5",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "12"
      },
      {
        "model": "simatic hmi comfort panels",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "12"
      },
      {
        "model": "simatic hmi comfort panels",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic hmi comfort outdoor panels",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic hmi classic devices",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic wincc runtime professional update",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "154"
      },
      {
        "model": "simatic wincc runtime advanced update",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "154"
      },
      {
        "model": "simatic wincc update",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "154"
      },
      {
        "model": "simatic hmi ktp mobile panels update",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "154"
      },
      {
        "model": "simatic hmi comfort panels update",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "154"
      },
      {
        "model": "simatic hmi comfort outdoor panels update",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "154"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic hmi comfort panels",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic hmi mp",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic hmi op",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic hmi comfort outdoor panels",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic hmi ktp mobile panels ktp400f",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic hmi ktp mobile panels ktp700",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic hmi ktp mobile panels ktp700f",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic hmi ktp mobile panels ktp900",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic hmi ktp mobile panels ktp900f",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic wincc tia portal",
        "version": "*"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.2,
        "vendor": "simatic hmi tp",
        "version": "*"
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "e30112c1-39ab-11e9-9eae-000c29342cb1"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-24247"
      },
      {
        "db": "BID",
        "id": "105922"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-014526"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-13813"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_hmi_comfort_outdoor_panels_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_hmi_comfort_panels",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/a:siemens:simatic_wincc_%28tia_portal%29",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/a:siemens:wincc_runtime_advanced",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/a:siemens:simatic_wincc_runtime_professional",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-014526"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Hosni Tounsi from Carthage Red Team",
    "sources": [
      {
        "db": "BID",
        "id": "105922"
      }
    ],
    "trust": 0.3
  },
  "cve": "CVE-2018-13813",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "NONE",
            "baseScore": 5.8,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 8.6,
            "id": "CVE-2018-13813",
            "impactScore": 4.9,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 1.8,
            "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:N",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "NONE",
            "baseScore": 7.8,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "CNVD-2018-24247",
            "impactScore": 6.9,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:C/A:N",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "IVD",
            "availabilityImpact": "NONE",
            "baseScore": 7.8,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 10.0,
            "id": "e30112c1-39ab-11e9-9eae-000c29342cb1",
            "impactScore": 6.9,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.2,
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:C/A:N",
            "version": "2.9 [IVD]"
          },
          {
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "NONE",
            "baseScore": 5.8,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 8.6,
            "id": "VHN-123910",
            "impactScore": 4.9,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 0.1,
            "vectorString": "AV:N/AC:M/AU:N/C:P/I:P/A:N",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "NONE",
            "baseScore": 8.1,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 2.8,
            "id": "CVE-2018-13813",
            "impactScore": 5.2,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.8,
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:N",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2018-13813",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "NVD",
            "id": "CVE-2018-13813",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2018-24247",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201811-483",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "IVD",
            "id": "e30112c1-39ab-11e9-9eae-000c29342cb1",
            "trust": 0.2,
            "value": "HIGH"
          },
          {
            "author": "VULHUB",
            "id": "VHN-123910",
            "trust": 0.1,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "e30112c1-39ab-11e9-9eae-000c29342cb1"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-24247"
      },
      {
        "db": "VULHUB",
        "id": "VHN-123910"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-014526"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201811-483"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-13813"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A vulnerability has been identified in SIMATIC HMI Comfort Panels 4\" - 22\" (All versions \u003c V15 Update 4), SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (All versions \u003c V15 Update 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15 Update 4), SIMATIC WinCC Runtime Advanced (All versions \u003c V15 Update 4), SIMATIC WinCC Runtime Professional (All versions \u003c V15 Update 4), SIMATIC WinCC (TIA Portal) (All versions \u003c V15 Update 4), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The webserver of affected HMI devices may allow URL redirections to untrusted websites. An attacker must trick a valid user who is authenticated to the device into clicking on a malicious link to exploit the vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known. plural SIMATIC The product contains an open redirect vulnerability.Information may be obtained and information may be altered. Siemens SIMATIC HMI Comfort Panels are all Germany\u0027s Siemens (Siemens) company HMI software for control and monitoring of machines and equipment. \n\nThe webserver in several Siemens products has an open redirection vulnerability. Siemens SIMATIC Panels is prone to following security vulnerabilities:\n1. An open-redirection vulnerability\n2. A directory-traversal vulnerability\nRemote attackers may use a specially crafted request with  directory-traversal sequences (\u0027../\u0027) to retrieve arbitrary files from  the affected system in the context of the application or by constructing a crafted URI and enticing a user to follow it and when an unsuspecting victim follows the link, they may be redirected to an attacker-controlled site",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2018-13813"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-014526"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-24247"
      },
      {
        "db": "BID",
        "id": "105922"
      },
      {
        "db": "IVD",
        "id": "e30112c1-39ab-11e9-9eae-000c29342cb1"
      },
      {
        "db": "VULHUB",
        "id": "VHN-123910"
      }
    ],
    "trust": 2.7
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2018-13813",
        "trust": 3.6
      },
      {
        "db": "SIEMENS",
        "id": "SSA-233109",
        "trust": 2.3
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-18-317-08",
        "trust": 2.3
      },
      {
        "db": "BID",
        "id": "105922",
        "trust": 2.0
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201811-483",
        "trust": 0.9
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-24247",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-014526",
        "trust": 0.8
      },
      {
        "db": "IVD",
        "id": "E30112C1-39AB-11E9-9EAE-000C29342CB1",
        "trust": 0.2
      },
      {
        "db": "VULHUB",
        "id": "VHN-123910",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "e30112c1-39ab-11e9-9eae-000c29342cb1"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-24247"
      },
      {
        "db": "VULHUB",
        "id": "VHN-123910"
      },
      {
        "db": "BID",
        "id": "105922"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-014526"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201811-483"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-13813"
      }
    ]
  },
  "id": "VAR-201812-0344",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "IVD",
        "id": "e30112c1-39ab-11e9-9eae-000c29342cb1"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-24247"
      },
      {
        "db": "VULHUB",
        "id": "VHN-123910"
      }
    ],
    "trust": 1.59438617
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "e30112c1-39ab-11e9-9eae-000c29342cb1"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-24247"
      }
    ]
  },
  "last_update_date": "2024-11-23T22:17:14.847000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "SSA-233109",
        "trust": 0.8,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-233109.pdf"
      },
      {
        "title": "Patch for Multiple Siemens products open redirection vulnerability",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/176377"
      },
      {
        "title": "Multiple Siemens Product security vulnerabilities",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=86884"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-24247"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-014526"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201811-483"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-601",
        "trust": 1.9
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-123910"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-014526"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-13813"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.3,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-233109.pdf"
      },
      {
        "trust": 2.3,
        "url": "https://ics-cert.us-cert.gov/advisories/icsa-18-317-08"
      },
      {
        "trust": 1.7,
        "url": "http://www.securityfocus.com/bid/105922"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-13813"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2018-13813"
      },
      {
        "trust": 0.3,
        "url": "http://subscriber.communications.siemens.com/"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2018-24247"
      },
      {
        "db": "VULHUB",
        "id": "VHN-123910"
      },
      {
        "db": "BID",
        "id": "105922"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-014526"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201811-483"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-13813"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "IVD",
        "id": "e30112c1-39ab-11e9-9eae-000c29342cb1"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2018-24247"
      },
      {
        "db": "VULHUB",
        "id": "VHN-123910"
      },
      {
        "db": "BID",
        "id": "105922"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-014526"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201811-483"
      },
      {
        "db": "NVD",
        "id": "CVE-2018-13813"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2018-11-29T00:00:00",
        "db": "IVD",
        "id": "e30112c1-39ab-11e9-9eae-000c29342cb1"
      },
      {
        "date": "2018-11-29T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2018-24247"
      },
      {
        "date": "2018-12-13T00:00:00",
        "db": "VULHUB",
        "id": "VHN-123910"
      },
      {
        "date": "2018-11-14T00:00:00",
        "db": "BID",
        "id": "105922"
      },
      {
        "date": "2019-03-26T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-014526"
      },
      {
        "date": "2018-11-15T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201811-483"
      },
      {
        "date": "2018-12-13T16:29:00.320000",
        "db": "NVD",
        "id": "CVE-2018-13813"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2019-08-22T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2018-24247"
      },
      {
        "date": "2019-10-09T00:00:00",
        "db": "VULHUB",
        "id": "VHN-123910"
      },
      {
        "date": "2018-11-14T00:00:00",
        "db": "BID",
        "id": "105922"
      },
      {
        "date": "2019-03-26T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2018-014526"
      },
      {
        "date": "2019-10-17T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201811-483"
      },
      {
        "date": "2024-11-21T03:48:07.380000",
        "db": "NVD",
        "id": "CVE-2018-13813"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201811-483"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "plural  SIMATIC Open redirect vulnerability in products",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2018-014526"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Input validation error",
    "sources": [
      {
        "db": "IVD",
        "id": "e30112c1-39ab-11e9-9eae-000c29342cb1"
      },
      {
        "db": "BID",
        "id": "105922"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201811-483"
      }
    ],
    "trust": 1.1
  }
}

VAR-201905-0115

Vulnerability from variot - Updated: 2024-11-23 21:37

A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Professional (All versions < V15.1 Update 1), SIMATIC WinCC (TIA Portal) (All versions < V15.1 Update 1), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The integrated web server could allow Cross-Site Scripting (XSS) attacks if an attacker is able to modify particular parts of the device configuration via SNMP. The security vulnerability could be exploited by an attacker with network access to the affected system. Successful exploitation requires system privileges and user interaction. An attacker could use the vulnerability to compromise confidentiality and the integrity of the affected system. At the stage of publishing this security advisory no public exploitation is known. plural SIMATIC The product contains a cross-site scripting vulnerability.Information may be obtained and information may be altered. Multiple Siemens Products are prone to following security vulnerabilities: 1. An information-disclosure vulnerability 2. A cross-site-scripting vulnerability 3. A security vulnerability An attacker may leverage these issues to obtain potentially sensitive information and to execute arbitrary script code in the browser of an unsuspecting user in the context of the affected site. This may allow the attacker to steal cookie-based authentication credentials and to launch other attacks. Siemens SIMATIC WinCC, etc. are all products of Siemens (Siemens) in Germany. SIMATIC WinCC is an automated data acquisition and monitoring (SCADA) system. Siemens SIMATIC HMI Comfort Panels is a touch panel device. Siemens SIMATIC HMI Comfort Outdoor Panels is a touch panel device specially designed for outdoor use. The vulnerability stems from the lack of correct validation of client data in WEB applications

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201905-0115",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "simatic hmi comfort outdoor panels",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "simatic wincc runtime",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "simatic hmi ktp mobile panels ktp900f",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "simatic hmi ktp mobile panels ktp700f",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "simatic wincc \\",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "simatic hmi mp",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic hmi comfort panels",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "simatic hmi op",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic hmi ktp mobile panels ktp900",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "simatic hmi ktp mobile panels ktp400f",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "simatic hmi ktp mobile panels ktp700",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "simatic hmi tp",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic hmi comfort outdoor panels",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic hmi comfort panels",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic hmi ktp mobile panels ktp400f",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic hmi ktp mobile panels ktp700",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic hmi ktp mobile panels ktp700f",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic hmi ktp mobile panels ktp900",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic hmi ktp mobile panels ktp900f",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic wincc",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic wincc runtime advanced",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic wincc runtime professional",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic wincc runtime professional",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "simatic wincc runtime professional",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "15"
      },
      {
        "model": "simatic wincc runtime advanced",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "simatic wincc runtime advanced",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "15"
      },
      {
        "model": "simatic wincc",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "v15.1"
      },
      {
        "model": "simatic wincc",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "v15"
      },
      {
        "model": "simatic hmi ktp mobile panels",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic hmi comfort panels",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "simatic hmi comfort panels",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "15"
      },
      {
        "model": "simatic hmi comfort outdoor panels",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "simatic hmi comfort outdoor panels",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "15"
      },
      {
        "model": "simatic hmi classic devices",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic wincc runtime professional update",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "v15.11"
      },
      {
        "model": "simatic wincc runtime advanced update",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "15.11"
      },
      {
        "model": "simatic wincc update",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "v15.11"
      },
      {
        "model": "simatic hmi ktp mobile update",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "15.11"
      },
      {
        "model": "simatic hmi comfort panels update",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "15.11"
      },
      {
        "model": "simatic hmi comfort outdoor panels update",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "15.11"
      }
    ],
    "sources": [
      {
        "db": "BID",
        "id": "108412"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-004634"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-6577"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_hmi_comfort_outdoor_panels_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_hmi_comfort_panels",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/a:siemens:simatic_wincc",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/a:siemens:wincc_runtime_advanced",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/a:siemens:simatic_wincc_runtime_professional",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-004634"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Siemens ProductCERT reported these vulnerabilities to NCCIC.,Siemens ProductCERT",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201905-588"
      }
    ],
    "trust": 0.6
  },
  "cve": "CVE-2019-6577",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "NONE",
            "baseScore": 3.5,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 6.8,
            "id": "CVE-2019-6577",
            "impactScore": 2.9,
            "integrityImpact": "PARTIAL",
            "severity": "LOW",
            "trust": 1.8,
            "vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N",
            "version": "2.0"
          },
          {
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "VULHUB",
            "availabilityImpact": "NONE",
            "baseScore": 3.5,
            "confidentialityImpact": "NONE",
            "exploitabilityScore": 6.8,
            "id": "VHN-158012",
            "impactScore": 2.9,
            "integrityImpact": "PARTIAL",
            "severity": "LOW",
            "trust": 0.1,
            "vectorString": "AV:N/AC:M/AU:S/C:N/I:P/A:N",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "NONE",
            "baseScore": 5.4,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "exploitabilityScore": 2.3,
            "id": "CVE-2019-6577",
            "impactScore": 2.7,
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "CHANGED",
            "trust": 1.8,
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2019-6577",
            "trust": 1.0,
            "value": "MEDIUM"
          },
          {
            "author": "NVD",
            "id": "CVE-2019-6577",
            "trust": 0.8,
            "value": "Medium"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201905-588",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "VULHUB",
            "id": "VHN-158012",
            "trust": 0.1,
            "value": "LOW"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-158012"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-004634"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201905-588"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-6577"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A vulnerability has been identified in SIMATIC HMI Comfort Panels 4\" - 22\" (All versions \u003c V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (All versions \u003c V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions \u003c V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions \u003c V15.1 Update 1), SIMATIC WinCC Runtime Professional (All versions \u003c V15.1 Update 1), SIMATIC WinCC (TIA Portal) (All versions \u003c V15.1 Update 1), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The integrated web server could allow Cross-Site Scripting (XSS) attacks if an attacker is able to modify particular parts of the device configuration via SNMP. The security vulnerability could be exploited by an attacker with network access to the affected system. Successful exploitation requires system privileges and user interaction. An attacker could use the vulnerability to compromise confidentiality and the integrity of the affected system. At the stage of publishing this security advisory no public exploitation is known. plural SIMATIC The product contains a cross-site scripting vulnerability.Information may be obtained and information may be altered. Multiple Siemens Products are prone to following security vulnerabilities:\n1. An information-disclosure vulnerability\n2. A cross-site-scripting vulnerability\n3. A security vulnerability\nAn attacker may leverage these issues to obtain potentially sensitive information and to execute arbitrary script code in the browser of an unsuspecting user in the context of the affected site. This may allow the attacker to steal cookie-based authentication credentials and to launch other attacks. Siemens SIMATIC WinCC, etc. are all products of Siemens (Siemens) in Germany. SIMATIC WinCC is an automated data acquisition and monitoring (SCADA) system. Siemens SIMATIC HMI Comfort Panels is a touch panel device. Siemens SIMATIC HMI Comfort Outdoor Panels is a touch panel device specially designed for outdoor use. The vulnerability stems from the lack of correct validation of client data in WEB applications",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2019-6577"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-004634"
      },
      {
        "db": "BID",
        "id": "108412"
      },
      {
        "db": "VULHUB",
        "id": "VHN-158012"
      }
    ],
    "trust": 1.98
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2019-6577",
        "trust": 2.8
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-19-134-09",
        "trust": 2.8
      },
      {
        "db": "BID",
        "id": "108412",
        "trust": 2.0
      },
      {
        "db": "SIEMENS",
        "id": "SSA-804486",
        "trust": 1.7
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-004634",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201905-588",
        "trust": 0.7
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-19-134-02",
        "trust": 0.6
      },
      {
        "db": "AUSCERT",
        "id": "ESB-2019.1716.2",
        "trust": 0.6
      },
      {
        "db": "CNVD",
        "id": "CNVD-2021-54365",
        "trust": 0.1
      },
      {
        "db": "VULHUB",
        "id": "VHN-158012",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-158012"
      },
      {
        "db": "BID",
        "id": "108412"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-004634"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201905-588"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-6577"
      }
    ]
  },
  "id": "VAR-201905-0115",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-158012"
      }
    ],
    "trust": 0.7545892989999999
  },
  "last_update_date": "2024-11-23T21:37:16.753000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "SSA-804486",
        "trust": 0.8,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-804486.pdf"
      },
      {
        "title": "Siemens SIMATIC Panels  and WinCC Fixes for cross-site scripting vulnerabilities",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=92738"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-004634"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201905-588"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-79",
        "trust": 1.9
      },
      {
        "problemtype": "CWE-80",
        "trust": 1.0
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-158012"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-004634"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-6577"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.3,
        "url": "http://www.securityfocus.com/bid/108412"
      },
      {
        "trust": 1.9,
        "url": "https://www.us-cert.gov/ics/advisories/icsa-19-134-09"
      },
      {
        "trust": 1.7,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-804486.pdf"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2019-6577"
      },
      {
        "trust": 0.9,
        "url": "http://subscriber.communications.siemens.com/"
      },
      {
        "trust": 0.9,
        "url": "https://ics-cert.us-cert.gov/advisories/icsa-19-134-09"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-6577"
      },
      {
        "trust": 0.6,
        "url": "https://ics-cert.us-cert.gov/advisories/icsa-19-134-02-0"
      },
      {
        "trust": 0.6,
        "url": "https://vigilance.fr/vulnerability/simatic-wincc-multiple-vulnerabilities-29288"
      },
      {
        "trust": 0.6,
        "url": "https://www.auscert.org.au/bulletins/80946"
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-158012"
      },
      {
        "db": "BID",
        "id": "108412"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-004634"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201905-588"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-6577"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "VULHUB",
        "id": "VHN-158012"
      },
      {
        "db": "BID",
        "id": "108412"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-004634"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201905-588"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-6577"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2019-05-14T00:00:00",
        "db": "VULHUB",
        "id": "VHN-158012"
      },
      {
        "date": "2019-05-14T00:00:00",
        "db": "BID",
        "id": "108412"
      },
      {
        "date": "2019-06-05T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2019-004634"
      },
      {
        "date": "2019-05-14T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201905-588"
      },
      {
        "date": "2019-05-14T20:29:04.623000",
        "db": "NVD",
        "id": "CVE-2019-6577"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2019-05-22T00:00:00",
        "db": "VULHUB",
        "id": "VHN-158012"
      },
      {
        "date": "2019-05-14T00:00:00",
        "db": "BID",
        "id": "108412"
      },
      {
        "date": "2019-07-09T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2019-004634"
      },
      {
        "date": "2019-05-23T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201905-588"
      },
      {
        "date": "2024-11-21T04:46:44.267000",
        "db": "NVD",
        "id": "CVE-2019-6577"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201905-588"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "plural  SIMATIC Product cross-site scripting vulnerability",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-004634"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "XSS",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201905-588"
      }
    ],
    "trust": 0.6
  }
}

VAR-201905-0114

Vulnerability from variot - Updated: 2024-11-23 21:37

A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Professional (All versions < V15.1 Update 1), SIMATIC WinCC (TIA Portal) (All versions < V15.1 Update 1), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). An attacker with network access to affected devices could potentially obtain a TLS session key. If the attacker is able to observe TLS traffic between a legitimate user and the device, then the attacker could decrypt the TLS traffic. The security vulnerability could be exploited by an attacker who has network access to the web interface of the device and who is able to observe TLS traffic between legitimate users and the web interface of the affected device. The vulnerability could impact the confidentiality of the communication between the affected device and a legitimate user. At the time of advisory publication no public exploitation of the security vulnerability was known. plural SIMATIC The product contains cryptographic vulnerabilities.Information may be obtained. Multiple Siemens Products are prone to following security vulnerabilities: 1. An information-disclosure vulnerability 2. A cross-site-scripting vulnerability 3. A security vulnerability An attacker may leverage these issues to obtain potentially sensitive information and to execute arbitrary script code in the browser of an unsuspecting user in the context of the affected site. This may allow the attacker to steal cookie-based authentication credentials and to launch other attacks. Siemens SIMATIC WinCC, etc. are all products of Siemens (Siemens) in Germany. SIMATIC WinCC is an automated data acquisition and monitoring (SCADA) system. Siemens SIMATIC HMI Comfort Panels is a touch panel device. Siemens SIMATIC HMI Comfort Outdoor Panels is a touch panel device specially designed for outdoor use

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201905-0114",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "simatic hmi comfort outdoor panels",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "simatic wincc runtime",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "simatic hmi ktp mobile panels ktp900f",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "simatic hmi ktp mobile panels ktp700f",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "simatic wincc \\",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "simatic hmi mp",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic hmi comfort panels",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "simatic hmi op",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic hmi ktp mobile panels ktp900",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "simatic hmi ktp mobile panels ktp400f",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "simatic hmi ktp mobile panels ktp700",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "simatic hmi tp",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic hmi comfort outdoor panels",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic hmi comfort panels",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic hmi ktp mobile panels ktp400f",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic hmi ktp mobile panels ktp700",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic hmi ktp mobile panels ktp700f",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic hmi ktp mobile panels ktp900",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic hmi ktp mobile panels ktp900f",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic wincc",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic wincc runtime advanced",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic wincc runtime professional",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic wincc runtime professional",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "simatic wincc runtime professional",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "15"
      },
      {
        "model": "simatic wincc runtime advanced",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "simatic wincc runtime advanced",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "15"
      },
      {
        "model": "simatic wincc",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "v15.1"
      },
      {
        "model": "simatic wincc",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "v15"
      },
      {
        "model": "simatic hmi ktp mobile panels",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic hmi comfort panels",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "simatic hmi comfort panels",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "15"
      },
      {
        "model": "simatic hmi comfort outdoor panels",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "simatic hmi comfort outdoor panels",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "15"
      },
      {
        "model": "simatic hmi classic devices",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic wincc runtime professional update",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "v15.11"
      },
      {
        "model": "simatic wincc runtime advanced update",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "15.11"
      },
      {
        "model": "simatic wincc update",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "v15.11"
      },
      {
        "model": "simatic hmi ktp mobile update",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "15.11"
      },
      {
        "model": "simatic hmi comfort panels update",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "15.11"
      },
      {
        "model": "simatic hmi comfort outdoor panels update",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "15.11"
      }
    ],
    "sources": [
      {
        "db": "BID",
        "id": "108412"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-004633"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-6576"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_hmi_comfort_outdoor_panels_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_hmi_comfort_panels",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/a:siemens:simatic_wincc",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/a:siemens:wincc_runtime_advanced",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/a:siemens:simatic_wincc_runtime_professional",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-004633"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Siemens ProductCERT reported these vulnerabilities to NCCIC.,Siemens ProductCERT",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201905-589"
      }
    ],
    "trust": 0.6
  },
  "cve": "CVE-2019-6576",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "NONE",
            "baseScore": 5.0,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CVE-2019-6576",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 1.8,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "NONE",
            "baseScore": 5.0,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "VHN-158011",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 0.1,
            "vectorString": "AV:N/AC:L/AU:N/C:P/I:N/A:N",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "NONE",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2019-6576",
            "impactScore": 3.6,
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.8,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2019-6576",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "NVD",
            "id": "CVE-2019-6576",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201905-589",
            "trust": 0.6,
            "value": "HIGH"
          },
          {
            "author": "VULHUB",
            "id": "VHN-158011",
            "trust": 0.1,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-158011"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-004633"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201905-589"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-6576"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A vulnerability has been identified in SIMATIC HMI Comfort Panels 4\" - 22\" (All versions \u003c V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (All versions \u003c V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions \u003c V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions \u003c V15.1 Update 1), SIMATIC WinCC Runtime Professional (All versions \u003c V15.1 Update 1), SIMATIC WinCC (TIA Portal) (All versions \u003c V15.1 Update 1), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). An attacker with network access to affected devices could potentially obtain a TLS session key. If the attacker is able to observe TLS traffic between a legitimate user and the device, then the attacker could decrypt the TLS traffic. The security vulnerability could be exploited by an attacker who has network access to the web interface of the device and who is able to observe TLS traffic between legitimate users and the web interface of the affected device. The vulnerability could impact the confidentiality of the communication between the affected device and a legitimate user. At the time of advisory publication no public exploitation of the security vulnerability was known. plural SIMATIC The product contains cryptographic vulnerabilities.Information may be obtained. Multiple Siemens Products are prone to following security vulnerabilities:\n1. An information-disclosure vulnerability\n2. A cross-site-scripting vulnerability\n3. A security vulnerability\nAn attacker may leverage these issues to obtain potentially sensitive information and to execute arbitrary script code in the browser of an unsuspecting user in the context of the affected site. This may allow the attacker to steal cookie-based authentication credentials and to launch other attacks. Siemens SIMATIC WinCC, etc. are all products of Siemens (Siemens) in Germany. SIMATIC WinCC is an automated data acquisition and monitoring (SCADA) system. Siemens SIMATIC HMI Comfort Panels is a touch panel device. Siemens SIMATIC HMI Comfort Outdoor Panels is a touch panel device specially designed for outdoor use",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2019-6576"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-004633"
      },
      {
        "db": "BID",
        "id": "108412"
      },
      {
        "db": "VULHUB",
        "id": "VHN-158011"
      }
    ],
    "trust": 1.98
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "ICS CERT",
        "id": "ICSA-19-134-09",
        "trust": 2.8
      },
      {
        "db": "NVD",
        "id": "CVE-2019-6576",
        "trust": 2.8
      },
      {
        "db": "BID",
        "id": "108412",
        "trust": 2.0
      },
      {
        "db": "SIEMENS",
        "id": "SSA-804486",
        "trust": 1.7
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-004633",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201905-589",
        "trust": 0.7
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-19-134-02",
        "trust": 0.6
      },
      {
        "db": "AUSCERT",
        "id": "ESB-2019.1716.2",
        "trust": 0.6
      },
      {
        "db": "CNVD",
        "id": "CNVD-2021-54366",
        "trust": 0.1
      },
      {
        "db": "VULHUB",
        "id": "VHN-158011",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-158011"
      },
      {
        "db": "BID",
        "id": "108412"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-004633"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201905-589"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-6576"
      }
    ]
  },
  "id": "VAR-201905-0114",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-158011"
      }
    ],
    "trust": 0.7545892989999999
  },
  "last_update_date": "2024-11-23T21:37:16.690000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "SSA-804486",
        "trust": 0.8,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-804486.pdf"
      },
      {
        "title": "Siemens SIMATIC Panels  and WinCC Security vulnerabilities",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=92739"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-004633"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201905-589"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-310",
        "trust": 1.9
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-158011"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-004633"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-6576"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.3,
        "url": "http://www.securityfocus.com/bid/108412"
      },
      {
        "trust": 1.9,
        "url": "https://www.us-cert.gov/ics/advisories/icsa-19-134-09"
      },
      {
        "trust": 1.7,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-804486.pdf"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2019-6576"
      },
      {
        "trust": 0.9,
        "url": "http://subscriber.communications.siemens.com/"
      },
      {
        "trust": 0.9,
        "url": "https://ics-cert.us-cert.gov/advisories/icsa-19-134-09"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-6576"
      },
      {
        "trust": 0.6,
        "url": "https://ics-cert.us-cert.gov/advisories/icsa-19-134-02-0"
      },
      {
        "trust": 0.6,
        "url": "https://vigilance.fr/vulnerability/simatic-wincc-multiple-vulnerabilities-29288"
      },
      {
        "trust": 0.6,
        "url": "https://www.auscert.org.au/bulletins/80946"
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-158011"
      },
      {
        "db": "BID",
        "id": "108412"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-004633"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201905-589"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-6576"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "VULHUB",
        "id": "VHN-158011"
      },
      {
        "db": "BID",
        "id": "108412"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-004633"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201905-589"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-6576"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2019-05-14T00:00:00",
        "db": "VULHUB",
        "id": "VHN-158011"
      },
      {
        "date": "2019-05-14T00:00:00",
        "db": "BID",
        "id": "108412"
      },
      {
        "date": "2019-06-05T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2019-004633"
      },
      {
        "date": "2019-05-14T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201905-589"
      },
      {
        "date": "2019-05-14T20:29:04.560000",
        "db": "NVD",
        "id": "CVE-2019-6576"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2019-05-22T00:00:00",
        "db": "VULHUB",
        "id": "VHN-158011"
      },
      {
        "date": "2019-05-14T00:00:00",
        "db": "BID",
        "id": "108412"
      },
      {
        "date": "2019-07-09T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2019-004633"
      },
      {
        "date": "2019-06-20T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201905-589"
      },
      {
        "date": "2024-11-21T04:46:44.130000",
        "db": "NVD",
        "id": "CVE-2019-6576"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201905-589"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "plural  SIMATIC Cryptographic vulnerabilities in products",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-004633"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "encryption problem",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201905-589"
      }
    ],
    "trust": 0.6
  }
}

VAR-201905-0112

Vulnerability from variot - Updated: 2024-11-23 21:37

A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Professional (All versions < V15.1 Update 1), SIMATIC WinCC (TIA Portal) (All versions < V15.1 Update 1), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The affected device offered SNMP read and write capacities with a publicly know hardcoded community string. The security vulnerability could be exploited by an attacker with network access to the affected device. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise confidentiality and integrity of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known. plural SIMATIC The product contains vulnerabilities related to authorization, permissions, and access control.Information may be obtained and information may be altered. Multiple Siemens Products are prone to following security vulnerabilities: 1. An information-disclosure vulnerability 2. A cross-site-scripting vulnerability 3. A security vulnerability An attacker may leverage these issues to obtain potentially sensitive information and to execute arbitrary script code in the browser of an unsuspecting user in the context of the affected site. This may allow the attacker to steal cookie-based authentication credentials and to launch other attacks. Siemens SIMATIC WinCC, etc. are all products of Siemens (Siemens) in Germany. SIMATIC WinCC is an automated data acquisition and monitoring (SCADA) system. Siemens SIMATIC HMI Comfort Panels is a touch panel device. Siemens SIMATIC HMI Comfort Outdoor Panels is a touch panel device specially designed for outdoor use. The vulnerability stems from the lack of effective permissions and access control measures in network systems or products

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-201905-0112",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "simatic hmi comfort outdoor panels",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "simatic wincc runtime",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "simatic hmi ktp mobile panels ktp900f",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "simatic hmi ktp mobile panels ktp700f",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "simatic wincc \\",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "simatic hmi mp",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic hmi comfort panels",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "simatic hmi op",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic hmi ktp mobile panels ktp900",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "simatic hmi ktp mobile panels ktp400f",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "simatic hmi ktp mobile panels ktp700",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "simatic hmi tp",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic hmi comfort outdoor panels",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic hmi comfort panels",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic hmi ktp mobile panels ktp400f",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic hmi ktp mobile panels ktp700",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic hmi ktp mobile panels ktp700f",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic hmi ktp mobile panels ktp900",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic hmi ktp mobile panels ktp900f",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic wincc",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic wincc runtime advanced",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic wincc runtime professional",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic wincc runtime professional",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "simatic wincc runtime professional",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "15"
      },
      {
        "model": "simatic wincc runtime advanced",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "simatic wincc runtime advanced",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "15"
      },
      {
        "model": "simatic wincc",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "v15.1"
      },
      {
        "model": "simatic wincc",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "v15"
      },
      {
        "model": "simatic hmi ktp mobile panels",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic hmi comfort panels",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "simatic hmi comfort panels",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "15"
      },
      {
        "model": "simatic hmi comfort outdoor panels",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "15.1"
      },
      {
        "model": "simatic hmi comfort outdoor panels",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "15"
      },
      {
        "model": "simatic hmi classic devices",
        "scope": "eq",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "0"
      },
      {
        "model": "simatic wincc runtime professional update",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "v15.11"
      },
      {
        "model": "simatic wincc runtime advanced update",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "15.11"
      },
      {
        "model": "simatic wincc update",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "v15.11"
      },
      {
        "model": "simatic hmi ktp mobile update",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "15.11"
      },
      {
        "model": "simatic hmi comfort panels update",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "15.11"
      },
      {
        "model": "simatic hmi comfort outdoor panels update",
        "scope": "ne",
        "trust": 0.3,
        "vendor": "siemens",
        "version": "15.11"
      }
    ],
    "sources": [
      {
        "db": "BID",
        "id": "108412"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-004632"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-6572"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_hmi_comfort_outdoor_panels_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_hmi_comfort_panels",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_hmi_ktp_mobile_panels_ktp400f_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_hmi_ktp_mobile_panels_ktp700_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_hmi_ktp_mobile_panels_ktp900_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_hmi_ktp_mobile_panels_ktp900f_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/a:siemens:simatic_wincc",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/a:siemens:wincc_runtime_advanced",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/a:siemens:simatic_wincc_runtime_professional",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-004632"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Siemens ProductCERT reported these vulnerabilities to NCCIC.,Siemens ProductCERT",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201905-590"
      }
    ],
    "trust": 0.6
  },
  "cve": "CVE-2019-6572",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "NONE",
            "baseScore": 6.4,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "CVE-2019-6572",
            "impactScore": 4.9,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 1.8,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:N",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "NONE",
            "baseScore": 6.4,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 10.0,
            "id": "VHN-158007",
            "impactScore": 4.9,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 0.1,
            "vectorString": "AV:N/AC:L/AU:N/C:P/I:P/A:N",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "nvd@nist.gov",
            "availabilityImpact": "NONE",
            "baseScore": 9.1,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 3.9,
            "id": "CVE-2019-6572",
            "impactScore": 5.2,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "None",
            "baseScore": 9.1,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2019-6572",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2019-6572",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "NVD",
            "id": "CVE-2019-6572",
            "trust": 0.8,
            "value": "Critical"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-201905-590",
            "trust": 0.6,
            "value": "CRITICAL"
          },
          {
            "author": "VULHUB",
            "id": "VHN-158007",
            "trust": 0.1,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-158007"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-004632"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201905-590"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-6572"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A vulnerability has been identified in SIMATIC HMI Comfort Panels 4\" - 22\" (All versions \u003c V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (All versions \u003c V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions \u003c V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions \u003c V15.1 Update 1), SIMATIC WinCC Runtime Professional (All versions \u003c V15.1 Update 1), SIMATIC WinCC (TIA Portal) (All versions \u003c V15.1 Update 1), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The affected device offered SNMP read and write capacities with a publicly know hardcoded community string. The security vulnerability could be exploited by an attacker with network access to the affected device. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise confidentiality and integrity of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known. plural SIMATIC The product contains vulnerabilities related to authorization, permissions, and access control.Information may be obtained and information may be altered. Multiple Siemens Products are prone to following security vulnerabilities:\n1. An information-disclosure vulnerability\n2. A cross-site-scripting vulnerability\n3. A security vulnerability\nAn attacker may leverage these issues to obtain potentially sensitive information and to execute arbitrary script code in the browser of an unsuspecting user in the context of the affected site. This may allow the attacker to steal cookie-based authentication credentials and to launch other attacks. Siemens SIMATIC WinCC, etc. are all products of Siemens (Siemens) in Germany. SIMATIC WinCC is an automated data acquisition and monitoring (SCADA) system. Siemens SIMATIC HMI Comfort Panels is a touch panel device. Siemens SIMATIC HMI Comfort Outdoor Panels is a touch panel device specially designed for outdoor use. The vulnerability stems from the lack of effective permissions and access control measures in network systems or products",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2019-6572"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-004632"
      },
      {
        "db": "BID",
        "id": "108412"
      },
      {
        "db": "VULHUB",
        "id": "VHN-158007"
      }
    ],
    "trust": 1.98
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "ICS CERT",
        "id": "ICSA-19-134-09",
        "trust": 2.8
      },
      {
        "db": "NVD",
        "id": "CVE-2019-6572",
        "trust": 2.8
      },
      {
        "db": "BID",
        "id": "108412",
        "trust": 2.0
      },
      {
        "db": "SIEMENS",
        "id": "SSA-804486",
        "trust": 1.7
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-004632",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201905-590",
        "trust": 0.7
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-19-134-02",
        "trust": 0.6
      },
      {
        "db": "AUSCERT",
        "id": "ESB-2019.1716.2",
        "trust": 0.6
      },
      {
        "db": "CNVD",
        "id": "CNVD-2021-54367",
        "trust": 0.1
      },
      {
        "db": "VULHUB",
        "id": "VHN-158007",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-158007"
      },
      {
        "db": "BID",
        "id": "108412"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-004632"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201905-590"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-6572"
      }
    ]
  },
  "id": "VAR-201905-0112",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-158007"
      }
    ],
    "trust": 0.7545892989999999
  },
  "last_update_date": "2024-11-23T21:37:16.658000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "SSA-804486",
        "trust": 0.8,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-804486.pdf"
      },
      {
        "title": "Siemens SIMATIC Panels  and WinCC Repair measures for trust management problem vulnerabilities",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=92740"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-004632"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201905-590"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-798",
        "trust": 1.1
      },
      {
        "problemtype": "CWE-200",
        "trust": 1.0
      },
      {
        "problemtype": "CWE-264",
        "trust": 0.9
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-158007"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-004632"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-6572"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.9,
        "url": "http://www.securityfocus.com/bid/108412"
      },
      {
        "trust": 2.5,
        "url": "https://www.us-cert.gov/ics/advisories/icsa-19-134-09"
      },
      {
        "trust": 1.7,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-804486.pdf"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2019-6572"
      },
      {
        "trust": 0.9,
        "url": "http://subscriber.communications.siemens.com/"
      },
      {
        "trust": 0.9,
        "url": "https://ics-cert.us-cert.gov/advisories/icsa-19-134-09"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-6572"
      },
      {
        "trust": 0.6,
        "url": "https://ics-cert.us-cert.gov/advisories/icsa-19-134-02-0"
      },
      {
        "trust": 0.6,
        "url": "https://vigilance.fr/vulnerability/simatic-wincc-multiple-vulnerabilities-29288"
      },
      {
        "trust": 0.6,
        "url": "https://www.auscert.org.au/bulletins/80946"
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-158007"
      },
      {
        "db": "BID",
        "id": "108412"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-004632"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201905-590"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-6572"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "VULHUB",
        "id": "VHN-158007"
      },
      {
        "db": "BID",
        "id": "108412"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-004632"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-201905-590"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-6572"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2019-05-14T00:00:00",
        "db": "VULHUB",
        "id": "VHN-158007"
      },
      {
        "date": "2019-05-14T00:00:00",
        "db": "BID",
        "id": "108412"
      },
      {
        "date": "2019-06-05T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2019-004632"
      },
      {
        "date": "2019-05-14T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201905-590"
      },
      {
        "date": "2019-05-14T20:29:04.200000",
        "db": "NVD",
        "id": "CVE-2019-6572"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2020-10-06T00:00:00",
        "db": "VULHUB",
        "id": "VHN-158007"
      },
      {
        "date": "2019-05-14T00:00:00",
        "db": "BID",
        "id": "108412"
      },
      {
        "date": "2019-07-09T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2019-004632"
      },
      {
        "date": "2020-10-28T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-201905-590"
      },
      {
        "date": "2024-11-21T04:46:43.653000",
        "db": "NVD",
        "id": "CVE-2019-6572"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201905-590"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "plural  SIMATIC Vulnerabilities related to authorization, authority, and access control in products",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-004632"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "trust management problem",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-201905-590"
      }
    ],
    "trust": 0.6
  }
}

VAR-202007-1238

Vulnerability from variot - Updated: 2024-11-23 21:35

A vulnerability has been identified in SIMATIC HMI Basic Panels 1st Generation (incl. SIPLUS variants) (All versions), SIMATIC HMI Basic Panels 2nd Generation (incl. SIPLUS variants) (All versions), SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions), SIMATIC HMI KTP700F Mobile Arctic (All versions), SIMATIC HMI Mobile Panels 2nd Generation (All versions), SIMATIC WinCC Runtime Advanced (All versions). Unencrypted communication between the configuration software and the respective device could allow an attacker to capture potential plain text communication and have access to sensitive information. Several Siemens products contain vulnerabilities in the transmission of important information in clear text.Information may be obtained. SIMATIC HMI Panels are used for operator control, monitoring of machines and equipment. SIMATIC WinCC Runtime Advanced is a visual runtime platform, monitoring of machines and equipment. SIPLUS extreme products are designed to operate under extreme conditions. It is based on Imatic, LOGO! SITOP, SINAMICS, SIMOTION, SCALANCE or other equipment

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202007-1238",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "simatic wincc runtime advanced",
        "scope": null,
        "trust": 1.4,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic hmi comfort panels",
        "scope": null,
        "trust": 1.4,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic hmi basic panels 2nd generation",
        "scope": null,
        "trust": 1.4,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic hmi basic panels 1st generation",
        "scope": null,
        "trust": 1.4,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic hmi mobile panels 2nd generation",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic wincc runtime advanced",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic hmi basic panels 2nd generation",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic hmi ktp700f mobile arctic",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic hmi comfort panels",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic hmi basic panels 1st generation",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic hmi ktp mobile panels ktp700f",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic hmi mobile panels 2nd generation",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic hmi ktp700f mobile arctic",
        "scope": null,
        "trust": 0.6,
        "vendor": "siemens",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-40613"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-008612"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-7592"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/h:siemens:simatic_hmi_basic_panels_generation_1",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/h:siemens:simatic_hmi_basic_panels_generation_2",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_hmi_comfort_panels",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/o:siemens:simatic_hmi_ktp_mobile_panels_ktp700f_firmware",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/a:siemens:wincc_runtime_advanced",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-008612"
      }
    ]
  },
  "cve": "CVE-2020-7592",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "ADJACENT_NETWORK",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "NONE",
            "baseScore": 3.3,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 6.5,
            "id": "CVE-2020-7592",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "LOW",
            "trust": 1.0,
            "vectorString": "AV:A/AC:L/Au:N/C:P/I:N/A:N",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "Low",
            "accessVector": "Adjacent Network",
            "authentication": "None",
            "author": "NVD",
            "availabilityImpact": "None",
            "baseScore": 3.3,
            "confidentialityImpact": "Partial",
            "exploitabilityScore": null,
            "id": "JVNDB-2020-008612",
            "impactScore": null,
            "integrityImpact": "None",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "Low",
            "trust": 0.8,
            "userInteractionRequired": null,
            "vectorString": "AV:A/AC:L/Au:N/C:P/I:N/A:N",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "ADJACENT_NETWORK",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "NONE",
            "baseScore": 6.1,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 6.5,
            "id": "CNVD-2020-40613",
            "impactScore": 6.9,
            "integrityImpact": "NONE",
            "severity": "MEDIUM",
            "trust": 0.6,
            "vectorString": "AV:A/AC:L/Au:N/C:C/I:N/A:N",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT",
            "author": "nvd@nist.gov",
            "availabilityImpact": "NONE",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 2.8,
            "id": "CVE-2020-7592",
            "impactScore": 3.6,
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Adjacent Network",
            "author": "NVD",
            "availabilityImpact": "None",
            "baseScore": 6.5,
            "baseSeverity": "Medium",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "JVNDB-2020-008612",
            "impactScore": null,
            "integrityImpact": "None",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2020-7592",
            "trust": 1.0,
            "value": "MEDIUM"
          },
          {
            "author": "NVD",
            "id": "JVNDB-2020-008612",
            "trust": 0.8,
            "value": "Medium"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2020-40613",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202007-578",
            "trust": 0.6,
            "value": "MEDIUM"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-40613"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-008612"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202007-578"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-7592"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A vulnerability has been identified in SIMATIC HMI Basic Panels 1st Generation (incl. SIPLUS variants) (All versions), SIMATIC HMI Basic Panels 2nd Generation (incl. SIPLUS variants) (All versions), SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions), SIMATIC HMI KTP700F Mobile Arctic (All versions), SIMATIC HMI Mobile Panels 2nd Generation (All versions), SIMATIC WinCC Runtime Advanced (All versions). Unencrypted communication between the configuration software and the respective device could allow an attacker to capture potential plain text communication and have access to sensitive information. Several Siemens products contain vulnerabilities in the transmission of important information in clear text.Information may be obtained. SIMATIC HMI Panels are used for operator control, monitoring of machines and equipment. SIMATIC WinCC Runtime Advanced is a visual runtime platform, monitoring of machines and equipment. SIPLUS extreme products are designed to operate under extreme conditions. It is based on Imatic, LOGO! SITOP, SINAMICS, SIMOTION, SCALANCE or other equipment",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2020-7592"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-008612"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2020-40613"
      }
    ],
    "trust": 2.16
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2020-7592",
        "trust": 3.0
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-20-196-04",
        "trust": 2.4
      },
      {
        "db": "SIEMENS",
        "id": "SSA-364335",
        "trust": 2.2
      },
      {
        "db": "JVN",
        "id": "JVNVU97872642",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-008612",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2020-40613",
        "trust": 0.6
      },
      {
        "db": "AUSCERT",
        "id": "ESB-2020.2387",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202007-578",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-40613"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-008612"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202007-578"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-7592"
      }
    ]
  },
  "id": "VAR-202007-1238",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-40613"
      }
    ],
    "trust": 1.2365613500000001
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS",
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-40613"
      }
    ]
  },
  "last_update_date": "2024-11-23T21:35:29.460000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "SSA-364335",
        "trust": 0.8,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-364335.pdf"
      },
      {
        "title": "Patch for Information Disclosure Vulnerabilities in Multiple Siemens Products",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/225825"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-40613"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-008612"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-319",
        "trust": 1.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-008612"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-7592"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.4,
        "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-196-04"
      },
      {
        "trust": 2.2,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-364335.pdf"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2020-7592"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-7592"
      },
      {
        "trust": 0.8,
        "url": "https://jvn.jp/vu/jvnvu97872642/"
      },
      {
        "trust": 0.6,
        "url": "https://vigilance.fr/vulnerability/simatic-information-disclosure-via-clear-text-transmission-32815"
      },
      {
        "trust": 0.6,
        "url": "https://www.auscert.org.au/bulletins/esb-2020.2387/"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-40613"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-008612"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202007-578"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-7592"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-40613"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-008612"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202007-578"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-7592"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2020-07-17T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2020-40613"
      },
      {
        "date": "2020-09-17T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2020-008612"
      },
      {
        "date": "2020-07-14T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202007-578"
      },
      {
        "date": "2020-07-14T14:15:19.073000",
        "db": "NVD",
        "id": "CVE-2020-7592"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2020-07-17T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2020-40613"
      },
      {
        "date": "2020-09-17T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2020-008612"
      },
      {
        "date": "2022-03-11T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202007-578"
      },
      {
        "date": "2024-11-21T05:37:26.090000",
        "db": "NVD",
        "id": "CVE-2020-7592"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote or local",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202007-578"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Vulnerability in plaintext transmission of critical information in multiple Siemens products",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-008612"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "other",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202007-578"
      }
    ],
    "trust": 0.6
  }
}

VAR-202006-1828

Vulnerability from variot - Updated: 2024-11-23 20:22

A vulnerability has been identified in SIMATIC Automation Tool (All versions < V4 SP2), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC NET PC Software V16 (All versions < V16 Upd3), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC ProSave (All versions < V17), SIMATIC S7-1500 Software Controller (All versions < V21.8), SIMATIC STEP 7 (TIA Portal) V13 (All versions < V13 SP2 Update 4), SIMATIC STEP 7 (TIA Portal) V14 (All versions < V14 SP1 Update 10), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMATIC STEP 7 V5 (All versions < V5.6 SP2 HF3), SIMATIC WinCC OA V3.16 (All versions < V3.16 P018), SIMATIC WinCC OA V3.17 (All versions < V3.17 P003), SIMATIC WinCC Runtime Advanced (All versions < V16 Update 2), SIMATIC WinCC Runtime Professional V13 (All versions < V13 SP2 Update 4), SIMATIC WinCC Runtime Professional V14 (All versions < V14 SP1 Update 10), SIMATIC WinCC Runtime Professional V15 (All versions < V15.1 Update 5), SIMATIC WinCC Runtime Professional V16 (All versions < V16 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 14), SIMATIC WinCC V7.5 (All versions < V7.5 SP1 Update 3), SINAMICS STARTER (All Versions < V5.4 HF2), SINAMICS Startdrive (All Versions < V16 Update 3), SINEC NMS (All versions < V1.0 SP2), SINEMA Server (All versions < V14 SP3), SINUMERIK ONE virtual (All Versions < V6.14), SINUMERIK Operate (All Versions < V6.14). A common component used by the affected applications regularly calls a helper binary with SYSTEM privileges while the call path is not quoted. This could allow a local attacker to execute arbitrary code with SYTEM privileges. plural SIMATIC The product contains vulnerabilities in unquoted search paths or elements.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. Opera Software, Opera, etc. are all products of Opera Software in Norway. Opera is a web browser, Siemens SIMATIC S7-1500, etc. are all products of German Siemens (Siemens). SIMATIC S7-1500 is a programmable logic controller. SIMATIC WinCC is an automated data acquisition and monitoring (SCADA) system. Code issue vulnerabilities exist in several products. This vulnerability stems from improper design or implementation problems in the code development process of network systems or products

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202006-1828",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "simatic pcs neo",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic prosave",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic wincc",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "7.5"
      },
      {
        "model": "simatic automatic tool",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic wincc runtime professional",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "13"
      },
      {
        "model": "simatic pcs 7",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "sinamics starter commissioning tool",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic wincc open architecture",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "3.17"
      },
      {
        "model": "simatic wincc runtime advanced",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic net pc",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "16"
      },
      {
        "model": "simatic net pc",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "16"
      },
      {
        "model": "simatic step 7",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "13"
      },
      {
        "model": "simatic wincc runtime professional",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "16"
      },
      {
        "model": "sinec network management system",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic step 7",
        "scope": "lte",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "16"
      },
      {
        "model": "sinema server",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic step 7",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.6"
      },
      {
        "model": "simatic wincc",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "7.4"
      },
      {
        "model": "sinamics startdrive",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "sinumerik one virtual",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "sinumerik operate",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic wincc open architecture",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "3.16"
      },
      {
        "model": "simatic wincc",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "7.4"
      },
      {
        "model": "simatic s7-1500 software controller",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "21.8"
      },
      {
        "model": "simatic step 7",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "5.6"
      },
      {
        "model": "simatic automation tool",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic net pc software",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic pcs 7",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic pcs neo",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic prosave",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic step 7",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic wincc",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic wincc oa",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic wincc runtime advanced",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "simatic wincc runtime professional",
        "scope": null,
        "trust": 0.8,
        "vendor": "siemens",
        "version": null
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-006496"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-7580"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "cpe_match": [
              {
                "cpe22Uri": "cpe:/a:siemens:simatic_automation_tool",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/a:siemens:simatic_net_pc-software",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/a:siemens:simatic_pcs_7",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/a:siemens:simatic_pcs_neo",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/a:siemens:simatic_prosave",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/a:siemens:simatic_step_7",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/a:siemens:simatic_wincc",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/a:siemens:simatic_wincc_open_architecture",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/a:siemens:wincc_runtime_advanced",
                "vulnerable": true
              },
              {
                "cpe22Uri": "cpe:/a:siemens:simatic_wincc_runtime_professional",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-006496"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Ander Martinez of Titanium Industrial Security and INCIBE reported this vulnerability to Siemens.",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202006-636"
      }
    ],
    "trust": 0.6
  },
  "cve": "CVE-2020-7580",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "LOCAL",
            "authentication": "NONE",
            "author": "nvd@nist.gov",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.2,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 3.9,
            "id": "CVE-2020-7580",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 1.1,
            "vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "Low",
            "accessVector": "Local",
            "authentication": "None",
            "author": "NVD",
            "availabilityImpact": "Complete",
            "baseScore": 7.2,
            "confidentialityImpact": "Complete",
            "exploitabilityScore": null,
            "id": "JVNDB-2020-006496",
            "impactScore": null,
            "integrityImpact": "Complete",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "High",
            "trust": 0.8,
            "userInteractionRequired": null,
            "vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "LOCAL",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.2,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 3.9,
            "id": "VHN-185705",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.1,
            "vectorString": "AV:L/AC:L/AU:N/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "author": "nvd@nist.gov",
            "availabilityImpact": "HIGH",
            "baseScore": 6.7,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 0.8,
            "id": "CVE-2020-7580",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Local",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 6.7,
            "baseSeverity": "Medium",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "JVNDB-2020-006496",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "High",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2020-7580",
            "trust": 1.0,
            "value": "MEDIUM"
          },
          {
            "author": "NVD",
            "id": "JVNDB-2020-006496",
            "trust": 0.8,
            "value": "Medium"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202006-636",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "VULHUB",
            "id": "VHN-185705",
            "trust": 0.1,
            "value": "HIGH"
          },
          {
            "author": "VULMON",
            "id": "CVE-2020-7580",
            "trust": 0.1,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-185705"
      },
      {
        "db": "VULMON",
        "id": "CVE-2020-7580"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-006496"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202006-636"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-7580"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A vulnerability has been identified in SIMATIC Automation Tool (All versions \u003c V4 SP2), SIMATIC NET PC Software V14 (All versions \u003c V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC NET PC Software V16 (All versions \u003c V16 Upd3), SIMATIC PCS neo (All versions \u003c V3.0 SP1), SIMATIC ProSave (All versions \u003c V17), SIMATIC S7-1500 Software Controller (All versions \u003c V21.8), SIMATIC STEP 7 (TIA Portal) V13 (All versions \u003c V13 SP2 Update 4), SIMATIC STEP 7 (TIA Portal) V14 (All versions \u003c V14 SP1 Update 10), SIMATIC STEP 7 (TIA Portal) V15 (All versions \u003c V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions \u003c V16 Update 2), SIMATIC STEP 7 V5 (All versions \u003c V5.6 SP2 HF3), SIMATIC WinCC OA V3.16 (All versions \u003c V3.16 P018), SIMATIC WinCC OA V3.17 (All versions \u003c V3.17 P003), SIMATIC WinCC Runtime Advanced (All versions \u003c V16 Update 2), SIMATIC WinCC Runtime Professional V13 (All versions \u003c V13 SP2 Update 4), SIMATIC WinCC Runtime Professional V14 (All versions \u003c V14 SP1 Update 10), SIMATIC WinCC Runtime Professional V15 (All versions \u003c V15.1 Update 5), SIMATIC WinCC Runtime Professional V16 (All versions \u003c V16 Update 2), SIMATIC WinCC V7.4 (All versions \u003c V7.4 SP1 Update 14), SIMATIC WinCC V7.5 (All versions \u003c V7.5 SP1 Update 3), SINAMICS STARTER (All Versions \u003c V5.4 HF2), SINAMICS Startdrive (All Versions \u003c V16 Update 3), SINEC NMS (All versions \u003c V1.0 SP2), SINEMA Server (All versions \u003c V14 SP3), SINUMERIK ONE virtual (All Versions \u003c V6.14), SINUMERIK Operate (All Versions \u003c V6.14). A common component used by the affected applications regularly calls a helper binary with SYSTEM privileges while the call path is not quoted. This could allow a local attacker to execute arbitrary code with SYTEM privileges. plural SIMATIC The product contains vulnerabilities in unquoted search paths or elements.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. Opera Software, Opera, etc. are all products of Opera Software in Norway. Opera is a web browser, Siemens SIMATIC S7-1500, etc. are all products of German Siemens (Siemens). SIMATIC S7-1500 is a programmable logic controller. SIMATIC WinCC is an automated data acquisition and monitoring (SCADA) system. Code issue vulnerabilities exist in several products. This vulnerability stems from improper design or implementation problems in the code development process of network systems or products",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2020-7580"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-006496"
      },
      {
        "db": "VULHUB",
        "id": "VHN-185705"
      },
      {
        "db": "VULMON",
        "id": "CVE-2020-7580"
      }
    ],
    "trust": 1.8
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2020-7580",
        "trust": 2.6
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-20-161-04",
        "trust": 2.6
      },
      {
        "db": "SIEMENS",
        "id": "SSA-312271",
        "trust": 1.8
      },
      {
        "db": "JVN",
        "id": "JVNVU97501786",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-006496",
        "trust": 0.8
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202006-636",
        "trust": 0.7
      },
      {
        "db": "AUSCERT",
        "id": "ESB-2020.2015",
        "trust": 0.6
      },
      {
        "db": "VULHUB",
        "id": "VHN-185705",
        "trust": 0.1
      },
      {
        "db": "VULMON",
        "id": "CVE-2020-7580",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-185705"
      },
      {
        "db": "VULMON",
        "id": "CVE-2020-7580"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-006496"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202006-636"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-7580"
      }
    ]
  },
  "id": "VAR-202006-1828",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-185705"
      }
    ],
    "trust": 0.6991104690909089
  },
  "last_update_date": "2024-11-23T20:22:32.187000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "SSA-312271:Unquoted Search Path Vulnerabilities in Windows-based Industrial Software Applications",
        "trust": 0.8,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-312271.pdf"
      },
      {
        "title": "Multiple Siemens Product code issue vulnerability fixes",
        "trust": 0.6,
        "url": "http://123.124.177.30/web/xxk/bdxqById.tag?id=121186"
      },
      {
        "title": "Siemens Security Advisories: Siemens Security Advisory",
        "trust": 0.1,
        "url": "https://vulmon.com/vendoradvisory?qidtp=siemens_security_advisories\u0026qid=9c51f352314e5a42566d9203d2f1e0a2"
      }
    ],
    "sources": [
      {
        "db": "VULMON",
        "id": "CVE-2020-7580"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-006496"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202006-636"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-428",
        "trust": 1.9
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-185705"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-006496"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-7580"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 3.2,
        "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-161-04"
      },
      {
        "trust": 1.8,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-312271.pdf"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2020-7580"
      },
      {
        "trust": 1.2,
        "url": "https://www.us-cert.gov/ics/advisories/icsa-20-161-04"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-7580"
      },
      {
        "trust": 0.8,
        "url": "https://jvn.jp/vu/jvnvu97501786/"
      },
      {
        "trust": 0.6,
        "url": "https://vigilance.fr/vulnerability/simatic-code-execution-via-windows-exe-extension-32489"
      },
      {
        "trust": 0.6,
        "url": "https://www.auscert.org.au/bulletins/esb-2020.2015/"
      },
      {
        "trust": 0.1,
        "url": "https://cwe.mitre.org/data/definitions/428.html"
      },
      {
        "trust": 0.1,
        "url": "https://nvd.nist.gov"
      },
      {
        "trust": 0.1,
        "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-20-161-04"
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-185705"
      },
      {
        "db": "VULMON",
        "id": "CVE-2020-7580"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-006496"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202006-636"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-7580"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "VULHUB",
        "id": "VHN-185705"
      },
      {
        "db": "VULMON",
        "id": "CVE-2020-7580"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-006496"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202006-636"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-7580"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2020-06-10T00:00:00",
        "db": "VULHUB",
        "id": "VHN-185705"
      },
      {
        "date": "2020-06-10T00:00:00",
        "db": "VULMON",
        "id": "CVE-2020-7580"
      },
      {
        "date": "2020-07-09T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2020-006496"
      },
      {
        "date": "2020-06-09T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202006-636"
      },
      {
        "date": "2020-06-10T17:15:12.347000",
        "db": "NVD",
        "id": "CVE-2020-7580"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2022-12-13T00:00:00",
        "db": "VULHUB",
        "id": "VHN-185705"
      },
      {
        "date": "2022-04-12T00:00:00",
        "db": "VULMON",
        "id": "CVE-2020-7580"
      },
      {
        "date": "2020-07-09T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2020-006496"
      },
      {
        "date": "2022-12-14T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202006-636"
      },
      {
        "date": "2024-11-21T05:37:24.840000",
        "db": "NVD",
        "id": "CVE-2020-7580"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "local",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202006-636"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "plural  SIMATIC Vulnerabilities in unquoted search paths or elements in products",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-006496"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "code problem",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202006-636"
      }
    ],
    "trust": 0.6
  }
}

CVE-2025-30033 (GCVE-0-2025-30033)

Vulnerability from nvd – Published: 2025-08-12 11:16 – Updated: 2025-12-09 10:44
VLAI?
Summary
The affected setup component is vulnerable to DLL hijacking. This could allow an attacker to execute arbitrary code when a legitimate user installs an application that uses the affected setup component.
CWE
  • CWE-427 - Uncontrolled Search Path Element
Assigner
Impacted products
Vendor Product Version
Siemens Automation License Manager V6.0 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens Automation License Manager V6.2 Affected: 0 , < V6.2 Upd3 (custom)
Create a notification for this product.
    Siemens CEMAT V10.0 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens CP PtP Param configuring interface Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens Create MyConfig (CMC) Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens Energy Support Library (EnSL) Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens FM Configuration Package Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens Modular PID CTRL Tool Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens MultiFieldbus Configuration Tool (MFCT) Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens OpenPCS 7 V10.0 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens OpenPCS 7 V9.1 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens Siemens Network Planner (SINETPLAN) Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC Automation Tool Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC Automation Tool SDK Windows Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC BATCH V10.0 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC BATCH V9.1 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC Control Function Library (CFL) V1.x Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC Control Function Library (CFL) V2.x Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC Control Function Library (CFL) V3.x Affected: 0 , < V3.1.0.2 (custom)
Create a notification for this product.
    Siemens SIMATIC Control Function Library (CFL) V4.x Affected: 0 , < V4.1 (custom)
Create a notification for this product.
    Siemens SIMATIC D7-SYS Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC eaSie Core Package Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC eaSie Document Skills Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC eaSie PCS 7 Skill Package Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC eaSie Workflow Skills Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC Energy Suite V17 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC Energy Suite V18 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC Energy Suite V19 Affected: 0 , < V19 Update 4 (custom)
Create a notification for this product.
    Siemens SIMATIC Logon V1.6 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC Logon V2.0 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC Management Agent Affected: 0 , < V9.1 SP1 Upd8 (custom)
Create a notification for this product.
    Siemens SIMATIC Management Console Affected: 0 , < V9.1 SP1 Upd8 (custom)
Create a notification for this product.
    Siemens SIMATIC MTP CREATOR V2.x Affected: 0 , < V2.1 (custom)
Create a notification for this product.
    Siemens SIMATIC MTP CREATOR V3.x Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC MTP CREATOR V4.x Affected: 0 , < V4.1.0.1 (custom)
Create a notification for this product.
    Siemens SIMATIC MTP CREATOR V5.x Affected: 0 , < V5.0.0.1 (custom)
Create a notification for this product.
    Siemens SIMATIC MTP Integrator V1.x Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC MTP Integrator V2.x Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC NET PC Software V16 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC NET PC Software V17 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC NET PC Software V18 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC NET PC Software V19 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC NET PC Software V20 Affected: 0 , < V20.0 Update 1 (custom)
Create a notification for this product.
    Siemens SIMATIC ODK 1500S Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC PCS 7 Advanced Process Faceplates V9.1 Affected: 0 , < V9.1 SP2 Upd4 (custom)
Create a notification for this product.
    Siemens SIMATIC PCS 7 Advanced Process Functions V2.1 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC PCS 7 Advanced Process Functions V2.2 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC PCS 7 Advanced Process Graphics V10.0 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC PCS 7 Advanced Process Graphics V9.1 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC PCS 7 Advanced Process Library incl. Faceplates V10.0 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC PCS 7 Advanced Process Library V9.1 Affected: 0 , < V9.1 SP2 Upd6 (custom)
Create a notification for this product.
    Siemens SIMATIC PCS 7 Basis Faceplates V9.1 Affected: 0 , < V9.1 SP2 Upd2 (custom)
Create a notification for this product.
    Siemens SIMATIC PCS 7 Basis Library V10.0 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC PCS 7 Basis Library V9.1 Affected: 0 , < V9.1 SP2 Upd8 (custom)
Create a notification for this product.
    Siemens SIMATIC PCS 7 Industry Library V10.0 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC PCS 7 Industry Library V9.0 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC PCS 7 Industry Library V9.1 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC PCS 7 Logic Matrix V10.0 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC PCS 7 Logic Matrix V9.1 Affected: 0 , < V9.1 Upd8 (custom)
Create a notification for this product.
    Siemens SIMATIC PCS 7 MPC Configurator Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC PCS 7 PowerControl Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC PCS 7 Standard Chemical Library V10.0 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC PCS 7 Standard Chemical Library V9.1 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC PCS 7 TeleControl Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC PCS 7 V10.0 Affected: 0 , < V10.0 SP1 UC01 (custom)
Create a notification for this product.
    Siemens SIMATIC PCS 7 V9.1 Affected: 0 , < V9.1 SP1 UC08 (custom)
Create a notification for this product.
    Siemens SIMATIC PCS 7/OPEN OS V9.1 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC PCS neo V5.0 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC PCS neo V6.0 Affected: 0 , < V6.0 SP1 (custom)
Create a notification for this product.
    Siemens SIMATIC PDM Maintenance Station V5.0 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC PDM V9.2 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC PDM V9.3 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC Process Function Library (PFL) V4.0 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC Process Historian 2020 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC Process Historian 2022 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC Process Historian 2024 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC ProSave V17 Affected: 0 , < V17 Update 9 (custom)
Create a notification for this product.
    Siemens SIMATIC ProSave V18 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC ProSave V19 Affected: 0 , < V19 Update 4 (custom)
Create a notification for this product.
    Siemens SIMATIC ProSave V20 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC Route Control V10.0 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC Route Control V9.1 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC S7 F Systems V6.3 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC S7 F Systems V6.4 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC S7-1500 Software Controller V2 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC S7-1500 Software Controller V3 Affected: 0 , < V31.1.5 (custom)
Create a notification for this product.
    Siemens SIMATIC S7-Fail-safe Configuration Tool (S7-FCT) Affected: 0 , < V4.0.1 (custom)
Create a notification for this product.
    Siemens SIMATIC S7-PCT Affected: 0 , < V3.5 SP4 Update 1 (custom)
Create a notification for this product.
    Siemens SIMATIC S7-PLCSIM Advanced Affected: 0 , < V7.0 Update 1 (custom)
Create a notification for this product.
    Siemens SIMATIC S7-PLCSIM V17 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC S7-PLCSIM V18 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC S7-PLCSIM V19 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC S7-PLCSIM V20 Affected: 0 , < V20 Update 1 (custom)
Create a notification for this product.
    Siemens SIMATIC Safety Matrix Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC STEP 7 CFC V19 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC STEP 7 CFC V20 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC STEP 7 V5.7 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC Target Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC WinCC flexible ES Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC WinCC Runtime Advanced Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC WinCC Runtime Professional Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC WinCC Runtime Professional V20 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC WinCC TeleControl Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC WinCC Unified Line Coordination Affected: 0 , < V20 (custom)
Create a notification for this product.
    Siemens SIMATIC WinCC Unified PC Runtime V18 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC WinCC Unified PC Runtime V19 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC WinCC Unified PC Runtime V20 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC WinCC Unified Sequence Affected: 0 , < V20 (custom)
Create a notification for this product.
    Siemens SIMATIC WinCC V7.5 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC WinCC V8.0 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC WinCC V8.1 Affected: 0 , < V8.1 Update 3 (custom)
Create a notification for this product.
    Siemens SIMATIC WinCC Visualization Architect (SiVArc) V17 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC WinCC Visualization Architect (SiVArc) V18 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC WinCC Visualization Architect (SiVArc) V19 Affected: 0 , < V19 Update 4 (custom)
Create a notification for this product.
    Siemens SIMATIC WinCC Visualization Architect (SiVArc) V20 Affected: 0 , < V20 Update 3 (custom)
Create a notification for this product.
    Siemens SIMIT Rapid Tester Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMIT Simulation Platform Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SINAMICS Startdrive V17 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SINAMICS Startdrive V18 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SINAMICS Startdrive V19 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SINAMICS Startdrive V20 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SINEC NMS Affected: 0 , < V4.0 (custom)
Create a notification for this product.
    Siemens SINEMA Remote Connect Client Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SITRANS Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens Standard PID CTRL Tool Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens TeleControl Server Basic V3.1 Affected: 0 , < V3.1.2.2 (custom)
Create a notification for this product.
    Siemens TIA Administrator Affected: 0 , < V3.0.6 (custom)
Create a notification for this product.
    Siemens TIA Portal Cloud Connector Affected: 0 , < V2.3 (custom)
Create a notification for this product.
    Siemens TIA Portal Test Suite V17 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens TIA Portal Test Suite V18 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens TIA Portal Test Suite V19 Affected: 0 , < V19 Update 4 (custom)
Create a notification for this product.
    Siemens TIA Portal Test Suite V20 Affected: 0 , < V20 Update 3 (custom)
Create a notification for this product.
    Siemens TIA Project-Server Affected: 0 , < V2.2 (custom)
Create a notification for this product.
    Siemens TIA Project-Server V17 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens Totally Integrated Automation Portal (TIA Portal) V17 Affected: 0 , < V17 Update 9 (custom)
Create a notification for this product.
    Siemens Totally Integrated Automation Portal (TIA Portal) V18 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens Totally Integrated Automation Portal (TIA Portal) V19 Affected: 0 , < V19 Update 4 (custom)
Create a notification for this product.
    Siemens Totally Integrated Automation Portal (TIA Portal) V20 Affected: 0 , < V20 Update 4 (custom)
Create a notification for this product.
    Siemens WinCC Panel Image Setup Affected: 0 , < * (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-30033",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-08-12T20:10:10.615077Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-08-12T20:10:30.205Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Automation License Manager V6.0",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Automation License Manager V6.2",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.2 Upd3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "CEMAT V10.0",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "CP PtP Param configuring interface",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Create MyConfig (CMC)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Energy Support Library (EnSL)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "FM Configuration Package",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Modular PID CTRL Tool",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "MultiFieldbus Configuration Tool\u00a0(MFCT)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "OpenPCS 7 V10.0",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "OpenPCS 7 V9.1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Siemens Network Planner (SINETPLAN)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Automation Tool",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Automation Tool SDK Windows",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC BATCH V10.0",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC BATCH V9.1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Control Function Library (CFL) V1.x",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Control Function Library (CFL) V2.x",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Control Function Library (CFL) V3.x",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.1.0.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Control Function Library (CFL) V4.x",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC\u00a0D7-SYS",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC eaSie Core Package",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC eaSie Document Skills",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC eaSie PCS 7 Skill Package",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC eaSie Workflow Skills",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Energy Suite V17",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Energy Suite V18",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Energy Suite V19",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V19 Update 4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Logon V1.6",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Logon V2.0",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Management Agent",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.1 SP1 Upd8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Management Console",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.1 SP1 Upd8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC MTP CREATOR\u00a0V2.x",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC MTP CREATOR V3.x",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC MTP CREATOR V4.x",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.0.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC MTP CREATOR\u00a0V5.x",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.0.0.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC MTP Integrator V1.x",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC MTP Integrator V2.x",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC NET PC Software V16",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC NET PC Software V17",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC NET PC Software V18",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC NET PC Software V19",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC NET PC Software V20",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V20.0 Update 1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ODK 1500S",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC PCS 7 Advanced Process Faceplates V9.1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.1 SP2 Upd4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC PCS 7 Advanced Process Functions V2.1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC PCS 7 Advanced Process Functions V2.2",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC PCS 7 Advanced Process Graphics V10.0",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC PCS 7 Advanced Process Graphics V9.1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC PCS 7 Advanced Process Library incl. Faceplates V10.0",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC PCS 7 Advanced Process Library V9.1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.1 SP2 Upd6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC PCS 7 Basis Faceplates V9.1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.1 SP2 Upd2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC PCS 7 Basis Library V10.0",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC PCS 7 Basis Library V9.1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.1 SP2 Upd8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC PCS 7 Industry Library V10.0",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC PCS 7 Industry Library V9.0",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC PCS 7 Industry Library V9.1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC PCS 7 Logic Matrix V10.0",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC PCS 7 Logic Matrix V9.1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.1 Upd8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC PCS 7 MPC Configurator",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC PCS 7 PowerControl",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC PCS 7 Standard Chemical Library V10.0",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC PCS 7 Standard Chemical Library V9.1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC PCS 7 TeleControl",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC PCS 7 V10.0",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V10.0 SP1 UC01",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC PCS 7 V9.1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.1 SP1 UC08",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC PCS 7/OPEN OS V9.1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC PCS neo V5.0",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC PCS neo V6.0",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.0 SP1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC PDM Maintenance Station V5.0",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC PDM V9.2",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC PDM V9.3",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Process Function Library (PFL) V4.0",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Process Historian 2020",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Process Historian 2022",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Process Historian 2024",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ProSave V17",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V17 Update 9",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ProSave V18",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ProSave V19",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V19 Update 4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ProSave V20",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Route Control V10.0",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Route Control V9.1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7 F Systems V6.3",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7 F Systems V6.4",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 Software Controller V2",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 Software Controller V3",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V31.1.5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-Fail-safe Configuration Tool (S7-FCT)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.0.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-PCT",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.5 SP4 Update 1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-PLCSIM Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.0 Update 1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-PLCSIM V17",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-PLCSIM V18",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-PLCSIM V19",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-PLCSIM V20",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V20 Update 1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Safety Matrix",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC STEP 7 CFC V19",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC STEP 7 CFC V20",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC STEP 7 V5.7",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Target",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinCC flexible ES",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinCC Runtime Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinCC Runtime Professional",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinCC Runtime Professional V20",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinCC TeleControl",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinCC Unified Line Coordination",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V20",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinCC Unified PC Runtime V18",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinCC Unified PC Runtime V19",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinCC Unified PC Runtime V20",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinCC Unified Sequence",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V20",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinCC V7.5",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinCC V8.0",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinCC V8.1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.1 Update 3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinCC Visualization Architect (SiVArc) V17",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinCC Visualization Architect (SiVArc) V18",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinCC Visualization Architect (SiVArc) V19",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V19 Update 4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinCC Visualization Architect (SiVArc) V20",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V20 Update 3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMIT Rapid Tester",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMIT Simulation Platform",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS Startdrive V17",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS Startdrive V18",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS Startdrive V19",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS Startdrive V20",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINEC NMS",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINEMA Remote Connect Client",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SITRANS",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Standard PID CTRL Tool",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "TeleControl Server Basic V3.1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.1.2.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "TIA Administrator",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "TIA Portal Cloud Connector",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "TIA Portal Test Suite V17",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "TIA Portal Test Suite V18",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "TIA Portal Test Suite V19",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V19 Update 4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "TIA Portal Test Suite V20",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V20 Update 3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "TIA Project-Server",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "TIA Project-Server V17",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Totally Integrated Automation Portal (TIA Portal) V17",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V17 Update 9",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Totally Integrated Automation Portal (TIA Portal) V18",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Totally Integrated Automation Portal (TIA Portal) V19",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V19 Update 4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Totally Integrated Automation Portal (TIA Portal) V20",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V20 Update 4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "WinCC Panel Image Setup",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "The affected setup component is vulnerable to DLL hijacking. This could allow an attacker to execute arbitrary code when a legitimate user installs an application that uses the affected setup component."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 8.5,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-427",
              "description": "CWE-427: Uncontrolled Search Path Element",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-12-09T10:44:20.878Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-282044.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2025-30033",
    "datePublished": "2025-08-12T11:16:56.565Z",
    "dateReserved": "2025-03-14T09:05:35.696Z",
    "dateUpdated": "2025-12-09T10:44:20.878Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-30033 (GCVE-0-2025-30033)

Vulnerability from cvelistv5 – Published: 2025-08-12 11:16 – Updated: 2025-12-09 10:44
VLAI?
Summary
The affected setup component is vulnerable to DLL hijacking. This could allow an attacker to execute arbitrary code when a legitimate user installs an application that uses the affected setup component.
CWE
  • CWE-427 - Uncontrolled Search Path Element
Assigner
Impacted products
Vendor Product Version
Siemens Automation License Manager V6.0 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens Automation License Manager V6.2 Affected: 0 , < V6.2 Upd3 (custom)
Create a notification for this product.
    Siemens CEMAT V10.0 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens CP PtP Param configuring interface Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens Create MyConfig (CMC) Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens Energy Support Library (EnSL) Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens FM Configuration Package Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens Modular PID CTRL Tool Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens MultiFieldbus Configuration Tool (MFCT) Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens OpenPCS 7 V10.0 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens OpenPCS 7 V9.1 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens Siemens Network Planner (SINETPLAN) Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC Automation Tool Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC Automation Tool SDK Windows Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC BATCH V10.0 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC BATCH V9.1 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC Control Function Library (CFL) V1.x Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC Control Function Library (CFL) V2.x Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC Control Function Library (CFL) V3.x Affected: 0 , < V3.1.0.2 (custom)
Create a notification for this product.
    Siemens SIMATIC Control Function Library (CFL) V4.x Affected: 0 , < V4.1 (custom)
Create a notification for this product.
    Siemens SIMATIC D7-SYS Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC eaSie Core Package Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC eaSie Document Skills Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC eaSie PCS 7 Skill Package Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC eaSie Workflow Skills Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC Energy Suite V17 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC Energy Suite V18 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC Energy Suite V19 Affected: 0 , < V19 Update 4 (custom)
Create a notification for this product.
    Siemens SIMATIC Logon V1.6 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC Logon V2.0 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC Management Agent Affected: 0 , < V9.1 SP1 Upd8 (custom)
Create a notification for this product.
    Siemens SIMATIC Management Console Affected: 0 , < V9.1 SP1 Upd8 (custom)
Create a notification for this product.
    Siemens SIMATIC MTP CREATOR V2.x Affected: 0 , < V2.1 (custom)
Create a notification for this product.
    Siemens SIMATIC MTP CREATOR V3.x Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC MTP CREATOR V4.x Affected: 0 , < V4.1.0.1 (custom)
Create a notification for this product.
    Siemens SIMATIC MTP CREATOR V5.x Affected: 0 , < V5.0.0.1 (custom)
Create a notification for this product.
    Siemens SIMATIC MTP Integrator V1.x Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC MTP Integrator V2.x Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC NET PC Software V16 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC NET PC Software V17 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC NET PC Software V18 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC NET PC Software V19 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC NET PC Software V20 Affected: 0 , < V20.0 Update 1 (custom)
Create a notification for this product.
    Siemens SIMATIC ODK 1500S Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC PCS 7 Advanced Process Faceplates V9.1 Affected: 0 , < V9.1 SP2 Upd4 (custom)
Create a notification for this product.
    Siemens SIMATIC PCS 7 Advanced Process Functions V2.1 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC PCS 7 Advanced Process Functions V2.2 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC PCS 7 Advanced Process Graphics V10.0 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC PCS 7 Advanced Process Graphics V9.1 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC PCS 7 Advanced Process Library incl. Faceplates V10.0 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC PCS 7 Advanced Process Library V9.1 Affected: 0 , < V9.1 SP2 Upd6 (custom)
Create a notification for this product.
    Siemens SIMATIC PCS 7 Basis Faceplates V9.1 Affected: 0 , < V9.1 SP2 Upd2 (custom)
Create a notification for this product.
    Siemens SIMATIC PCS 7 Basis Library V10.0 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC PCS 7 Basis Library V9.1 Affected: 0 , < V9.1 SP2 Upd8 (custom)
Create a notification for this product.
    Siemens SIMATIC PCS 7 Industry Library V10.0 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC PCS 7 Industry Library V9.0 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC PCS 7 Industry Library V9.1 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC PCS 7 Logic Matrix V10.0 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC PCS 7 Logic Matrix V9.1 Affected: 0 , < V9.1 Upd8 (custom)
Create a notification for this product.
    Siemens SIMATIC PCS 7 MPC Configurator Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC PCS 7 PowerControl Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC PCS 7 Standard Chemical Library V10.0 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC PCS 7 Standard Chemical Library V9.1 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC PCS 7 TeleControl Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC PCS 7 V10.0 Affected: 0 , < V10.0 SP1 UC01 (custom)
Create a notification for this product.
    Siemens SIMATIC PCS 7 V9.1 Affected: 0 , < V9.1 SP1 UC08 (custom)
Create a notification for this product.
    Siemens SIMATIC PCS 7/OPEN OS V9.1 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC PCS neo V5.0 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC PCS neo V6.0 Affected: 0 , < V6.0 SP1 (custom)
Create a notification for this product.
    Siemens SIMATIC PDM Maintenance Station V5.0 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC PDM V9.2 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC PDM V9.3 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC Process Function Library (PFL) V4.0 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC Process Historian 2020 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC Process Historian 2022 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC Process Historian 2024 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC ProSave V17 Affected: 0 , < V17 Update 9 (custom)
Create a notification for this product.
    Siemens SIMATIC ProSave V18 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC ProSave V19 Affected: 0 , < V19 Update 4 (custom)
Create a notification for this product.
    Siemens SIMATIC ProSave V20 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC Route Control V10.0 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC Route Control V9.1 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC S7 F Systems V6.3 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC S7 F Systems V6.4 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC S7-1500 Software Controller V2 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC S7-1500 Software Controller V3 Affected: 0 , < V31.1.5 (custom)
Create a notification for this product.
    Siemens SIMATIC S7-Fail-safe Configuration Tool (S7-FCT) Affected: 0 , < V4.0.1 (custom)
Create a notification for this product.
    Siemens SIMATIC S7-PCT Affected: 0 , < V3.5 SP4 Update 1 (custom)
Create a notification for this product.
    Siemens SIMATIC S7-PLCSIM Advanced Affected: 0 , < V7.0 Update 1 (custom)
Create a notification for this product.
    Siemens SIMATIC S7-PLCSIM V17 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC S7-PLCSIM V18 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC S7-PLCSIM V19 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC S7-PLCSIM V20 Affected: 0 , < V20 Update 1 (custom)
Create a notification for this product.
    Siemens SIMATIC Safety Matrix Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC STEP 7 CFC V19 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC STEP 7 CFC V20 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC STEP 7 V5.7 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC Target Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC WinCC flexible ES Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC WinCC Runtime Advanced Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC WinCC Runtime Professional Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC WinCC Runtime Professional V20 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC WinCC TeleControl Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC WinCC Unified Line Coordination Affected: 0 , < V20 (custom)
Create a notification for this product.
    Siemens SIMATIC WinCC Unified PC Runtime V18 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC WinCC Unified PC Runtime V19 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC WinCC Unified PC Runtime V20 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC WinCC Unified Sequence Affected: 0 , < V20 (custom)
Create a notification for this product.
    Siemens SIMATIC WinCC V7.5 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC WinCC V8.0 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC WinCC V8.1 Affected: 0 , < V8.1 Update 3 (custom)
Create a notification for this product.
    Siemens SIMATIC WinCC Visualization Architect (SiVArc) V17 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC WinCC Visualization Architect (SiVArc) V18 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMATIC WinCC Visualization Architect (SiVArc) V19 Affected: 0 , < V19 Update 4 (custom)
Create a notification for this product.
    Siemens SIMATIC WinCC Visualization Architect (SiVArc) V20 Affected: 0 , < V20 Update 3 (custom)
Create a notification for this product.
    Siemens SIMIT Rapid Tester Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SIMIT Simulation Platform Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SINAMICS Startdrive V17 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SINAMICS Startdrive V18 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SINAMICS Startdrive V19 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SINAMICS Startdrive V20 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SINEC NMS Affected: 0 , < V4.0 (custom)
Create a notification for this product.
    Siemens SINEMA Remote Connect Client Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens SITRANS Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens Standard PID CTRL Tool Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens TeleControl Server Basic V3.1 Affected: 0 , < V3.1.2.2 (custom)
Create a notification for this product.
    Siemens TIA Administrator Affected: 0 , < V3.0.6 (custom)
Create a notification for this product.
    Siemens TIA Portal Cloud Connector Affected: 0 , < V2.3 (custom)
Create a notification for this product.
    Siemens TIA Portal Test Suite V17 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens TIA Portal Test Suite V18 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens TIA Portal Test Suite V19 Affected: 0 , < V19 Update 4 (custom)
Create a notification for this product.
    Siemens TIA Portal Test Suite V20 Affected: 0 , < V20 Update 3 (custom)
Create a notification for this product.
    Siemens TIA Project-Server Affected: 0 , < V2.2 (custom)
Create a notification for this product.
    Siemens TIA Project-Server V17 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens Totally Integrated Automation Portal (TIA Portal) V17 Affected: 0 , < V17 Update 9 (custom)
Create a notification for this product.
    Siemens Totally Integrated Automation Portal (TIA Portal) V18 Affected: 0 , < * (custom)
Create a notification for this product.
    Siemens Totally Integrated Automation Portal (TIA Portal) V19 Affected: 0 , < V19 Update 4 (custom)
Create a notification for this product.
    Siemens Totally Integrated Automation Portal (TIA Portal) V20 Affected: 0 , < V20 Update 4 (custom)
Create a notification for this product.
    Siemens WinCC Panel Image Setup Affected: 0 , < * (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-30033",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-08-12T20:10:10.615077Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-08-12T20:10:30.205Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Automation License Manager V6.0",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Automation License Manager V6.2",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.2 Upd3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "CEMAT V10.0",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "CP PtP Param configuring interface",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Create MyConfig (CMC)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Energy Support Library (EnSL)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "FM Configuration Package",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Modular PID CTRL Tool",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "MultiFieldbus Configuration Tool\u00a0(MFCT)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "OpenPCS 7 V10.0",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "OpenPCS 7 V9.1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Siemens Network Planner (SINETPLAN)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Automation Tool",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Automation Tool SDK Windows",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC BATCH V10.0",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC BATCH V9.1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Control Function Library (CFL) V1.x",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Control Function Library (CFL) V2.x",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Control Function Library (CFL) V3.x",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.1.0.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Control Function Library (CFL) V4.x",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC\u00a0D7-SYS",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC eaSie Core Package",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC eaSie Document Skills",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC eaSie PCS 7 Skill Package",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC eaSie Workflow Skills",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Energy Suite V17",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Energy Suite V18",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Energy Suite V19",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V19 Update 4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Logon V1.6",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Logon V2.0",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Management Agent",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.1 SP1 Upd8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Management Console",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.1 SP1 Upd8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC MTP CREATOR\u00a0V2.x",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC MTP CREATOR V3.x",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC MTP CREATOR V4.x",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.0.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC MTP CREATOR\u00a0V5.x",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.0.0.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC MTP Integrator V1.x",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC MTP Integrator V2.x",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC NET PC Software V16",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC NET PC Software V17",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC NET PC Software V18",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC NET PC Software V19",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC NET PC Software V20",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V20.0 Update 1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ODK 1500S",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC PCS 7 Advanced Process Faceplates V9.1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.1 SP2 Upd4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC PCS 7 Advanced Process Functions V2.1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC PCS 7 Advanced Process Functions V2.2",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC PCS 7 Advanced Process Graphics V10.0",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC PCS 7 Advanced Process Graphics V9.1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC PCS 7 Advanced Process Library incl. Faceplates V10.0",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC PCS 7 Advanced Process Library V9.1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.1 SP2 Upd6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC PCS 7 Basis Faceplates V9.1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.1 SP2 Upd2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC PCS 7 Basis Library V10.0",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC PCS 7 Basis Library V9.1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.1 SP2 Upd8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC PCS 7 Industry Library V10.0",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC PCS 7 Industry Library V9.0",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC PCS 7 Industry Library V9.1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC PCS 7 Logic Matrix V10.0",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC PCS 7 Logic Matrix V9.1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.1 Upd8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC PCS 7 MPC Configurator",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC PCS 7 PowerControl",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC PCS 7 Standard Chemical Library V10.0",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC PCS 7 Standard Chemical Library V9.1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC PCS 7 TeleControl",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC PCS 7 V10.0",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V10.0 SP1 UC01",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC PCS 7 V9.1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V9.1 SP1 UC08",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC PCS 7/OPEN OS V9.1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC PCS neo V5.0",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC PCS neo V6.0",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.0 SP1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC PDM Maintenance Station V5.0",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC PDM V9.2",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC PDM V9.3",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Process Function Library (PFL) V4.0",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Process Historian 2020",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Process Historian 2022",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Process Historian 2024",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ProSave V17",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V17 Update 9",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ProSave V18",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ProSave V19",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V19 Update 4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ProSave V20",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Route Control V10.0",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Route Control V9.1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7 F Systems V6.3",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7 F Systems V6.4",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 Software Controller V2",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 Software Controller V3",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V31.1.5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-Fail-safe Configuration Tool (S7-FCT)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.0.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-PCT",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.5 SP4 Update 1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-PLCSIM Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.0 Update 1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-PLCSIM V17",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-PLCSIM V18",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-PLCSIM V19",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-PLCSIM V20",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V20 Update 1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Safety Matrix",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC STEP 7 CFC V19",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC STEP 7 CFC V20",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC STEP 7 V5.7",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Target",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinCC flexible ES",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinCC Runtime Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinCC Runtime Professional",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinCC Runtime Professional V20",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinCC TeleControl",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinCC Unified Line Coordination",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V20",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinCC Unified PC Runtime V18",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinCC Unified PC Runtime V19",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinCC Unified PC Runtime V20",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinCC Unified Sequence",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V20",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinCC V7.5",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinCC V8.0",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinCC V8.1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V8.1 Update 3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinCC Visualization Architect (SiVArc) V17",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinCC Visualization Architect (SiVArc) V18",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinCC Visualization Architect (SiVArc) V19",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V19 Update 4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinCC Visualization Architect (SiVArc) V20",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V20 Update 3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMIT Rapid Tester",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMIT Simulation Platform",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS Startdrive V17",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS Startdrive V18",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS Startdrive V19",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS Startdrive V20",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINEC NMS",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINEMA Remote Connect Client",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SITRANS",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Standard PID CTRL Tool",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "TeleControl Server Basic V3.1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.1.2.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "TIA Administrator",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "TIA Portal Cloud Connector",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "TIA Portal Test Suite V17",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "TIA Portal Test Suite V18",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "TIA Portal Test Suite V19",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V19 Update 4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "TIA Portal Test Suite V20",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V20 Update 3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "TIA Project-Server",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "TIA Project-Server V17",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Totally Integrated Automation Portal (TIA Portal) V17",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V17 Update 9",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Totally Integrated Automation Portal (TIA Portal) V18",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Totally Integrated Automation Portal (TIA Portal) V19",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V19 Update 4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Totally Integrated Automation Portal (TIA Portal) V20",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V20 Update 4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "WinCC Panel Image Setup",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "The affected setup component is vulnerable to DLL hijacking. This could allow an attacker to execute arbitrary code when a legitimate user installs an application that uses the affected setup component."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 8.5,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-427",
              "description": "CWE-427: Uncontrolled Search Path Element",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-12-09T10:44:20.878Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-282044.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2025-30033",
    "datePublished": "2025-08-12T11:16:56.565Z",
    "dateReserved": "2025-03-14T09:05:35.696Z",
    "dateUpdated": "2025-12-09T10:44:20.878Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}