CVE-2026-40852 (GCVE-0-2026-40852)
Vulnerability from nvd – Published: 2026-05-27 08:06 – Updated: 2026-05-27 11:54
VLAI
Title
Command injection via malicious configuration
Summary
A highly authenticated attacker can alter the config generator injecting a payload into future created configurations. The device is not correctly checking this configuration value before passing it to an system execute leading to code execution. This can result in a total loss of confidentiality, integrity and availability.
Severity
7.2 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
1 reference
Impacted products
8 products
| Vendor | Product | Version | |
|---|---|---|---|
| MB connect line | mbNET/mbNET.rokey |
Affected:
0.0.0 , ≤ 8.4.4
(semver)
|
|
| MB connect line | mbNET.mini |
Affected:
0.0.0 , ≤ 3.0.2
(semver)
|
|
| MB connect line | mbNET/mbNET.rokey |
Affected:
8.4.4
|
|
| MB connect line | mbNET.mini |
Affected:
3.0.2
|
|
| Helmholz | REX200/250 |
Affected:
0.0.0 , ≤ 8.4.4
(semver)
|
|
| Helmholz | REX100 |
Affected:
0.0.0 , ≤ 3.0.2
(semver)
|
|
| Helmholz | REX200/250 |
Affected:
8.4.4
|
|
| Helmholz | REX100 |
Affected:
3.0.2
|
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-40852",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-05-27T11:44:33.329985Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-05-27T11:54:17.274Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "mbNET/mbNET.rokey",
"vendor": "MB connect line",
"versions": [
{
"lessThanOrEqual": "8.4.4",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "mbNET.mini",
"vendor": "MB connect line",
"versions": [
{
"lessThanOrEqual": "3.0.2",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "mbNET/mbNET.rokey",
"vendor": "MB connect line",
"versions": [
{
"status": "affected",
"version": "8.4.4"
}
]
},
{
"defaultStatus": "unaffected",
"product": "mbNET.mini",
"vendor": "MB connect line",
"versions": [
{
"status": "affected",
"version": "3.0.2"
}
]
},
{
"defaultStatus": "unaffected",
"product": "REX200/250",
"vendor": "Helmholz",
"versions": [
{
"lessThanOrEqual": "8.4.4",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "REX100",
"vendor": "Helmholz",
"versions": [
{
"lessThanOrEqual": "3.0.2",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "REX200/250",
"vendor": "Helmholz",
"versions": [
{
"status": "affected",
"version": "8.4.4"
}
]
},
{
"defaultStatus": "unaffected",
"product": "REX100",
"vendor": "Helmholz",
"versions": [
{
"status": "affected",
"version": "3.0.2"
}
]
}
],
"cpeApplicability": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:mb_connect_line:mbnet_mbnet.rokey:*:*:*:*:*:*:*:*",
"versionEndIncluding": "8.4.4",
"versionStartIncluding": "0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:mb_connect_line:mbnet.mini:*:*:*:*:*:*:*:*",
"versionEndIncluding": "3.0.2",
"versionStartIncluding": "0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:mb_connect_line:mbnet:8.4.4:*:*:*:*:*:*:*",
"versionStartIncluding": "8.4.4",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:mb_connect_line:mbnet.mini:3.0.2:*:*:*:*:*:*:*",
"versionStartIncluding": "3.0.2",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:helmholz:rex200_250:*:*:*:*:*:*:*:*",
"versionEndIncluding": "8.4.4",
"versionStartIncluding": "0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:helmholz:rex100:*:*:*:*:*:*:*:*",
"versionEndIncluding": "3.0.2",
"versionStartIncluding": "0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:helmholz:rex200_250:8.4.4:*:*:*:*:*:*:*",
"versionStartIncluding": "8.4.4",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:helmholz:rex100:3.0.2:*:*:*:*:*:*:*",
"versionStartIncluding": "3.0.2",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Moritz Abrell from SySS GmbH"
},
{
"lang": "en",
"type": "finder",
"value": "Christian Z\u00e4ske from SySS GmbH"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eA highly authenticated attacker can alter the config generator injecting a payload into future created configurations. The device is not correctly checking this configuration value before passing it to an system execute leading to code execution. This can result in a total loss of confidentiality, integrity and availability.\u003c/p\u003e"
}
],
"value": "A highly authenticated attacker can alter the config generator injecting a payload into future created configurations. The device is not correctly checking this configuration value before passing it to an system execute leading to code execution. This can result in a total loss of confidentiality, integrity and availability."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-05-27T08:06:36.875Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://www.certvde.com/en/advisories/VDE-2026-054/"
}
],
"source": {
"advisory": "VDE-2026-054",
"defect": [
"CERT@VDE#642070"
],
"discovery": "UNKNOWN"
},
"title": "Command injection via malicious configuration",
"x_generator": {
"engine": "Vulnogram 0.4.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2026-40852",
"datePublished": "2026-05-27T08:06:36.875Z",
"dateReserved": "2026-04-15T09:33:02.614Z",
"dateUpdated": "2026-05-27T11:54:17.274Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-40851 (GCVE-0-2026-40851)
Vulnerability from nvd – Published: 2026-05-27 08:06 – Updated: 2026-05-27 11:54
VLAI
Title
Command injection via USB
Summary
A local attacker can perform a confusion attack on the cfgparser via a specially crafted file on an USB stick leading to code execution. This can result in a total loss of confidentiality, integrity and availability.
Severity
8.4 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-1287 - Improper Validation of Specified Type of Input
Assigner
References
1 reference
Impacted products
8 products
| Vendor | Product | Version | |
|---|---|---|---|
| MB connect line | mbNET/mbNET.rokey |
Affected:
0.0.0 , ≤ 8.4.4
(semver)
|
|
| MB connect line | mbNET.mini |
Affected:
0.0.0 , ≤ 3.0.2
(semver)
|
|
| MB connect line | mbNET/mbNET.rokey |
Affected:
8.4.4
|
|
| MB connect line | mbNET.mini |
Affected:
3.0.2
|
|
| Helmholz | REX200/250 |
Affected:
0.0.0 , ≤ 8.4.4
(semver)
|
|
| Helmholz | REX100 |
Affected:
0.0.0 , ≤ 3.0.2
(semver)
|
|
| Helmholz | REX200/250 |
Affected:
8.4.4
|
|
| Helmholz | REX100 |
Affected:
3.0.2
|
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-40851",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-05-27T11:44:44.253548Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-05-27T11:54:33.819Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "mbNET/mbNET.rokey",
"vendor": "MB connect line",
"versions": [
{
"lessThanOrEqual": "8.4.4",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "mbNET.mini",
"vendor": "MB connect line",
"versions": [
{
"lessThanOrEqual": "3.0.2",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "mbNET/mbNET.rokey",
"vendor": "MB connect line",
"versions": [
{
"status": "affected",
"version": "8.4.4"
}
]
},
{
"defaultStatus": "unaffected",
"product": "mbNET.mini",
"vendor": "MB connect line",
"versions": [
{
"status": "affected",
"version": "3.0.2"
}
]
},
{
"defaultStatus": "unaffected",
"product": "REX200/250",
"vendor": "Helmholz",
"versions": [
{
"lessThanOrEqual": "8.4.4",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "REX100",
"vendor": "Helmholz",
"versions": [
{
"lessThanOrEqual": "3.0.2",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "REX200/250",
"vendor": "Helmholz",
"versions": [
{
"status": "affected",
"version": "8.4.4"
}
]
},
{
"defaultStatus": "unaffected",
"product": "REX100",
"vendor": "Helmholz",
"versions": [
{
"status": "affected",
"version": "3.0.2"
}
]
}
],
"cpeApplicability": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:mb_connect_line:mbnet_mbnet.rokey:*:*:*:*:*:*:*:*",
"versionEndIncluding": "8.4.4",
"versionStartIncluding": "0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:mb_connect_line:mbnet.mini:*:*:*:*:*:*:*:*",
"versionEndIncluding": "3.0.2",
"versionStartIncluding": "0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:mb_connect_line:mbnet:8.4.4:*:*:*:*:*:*:*",
"versionStartIncluding": "8.4.4",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:mb_connect_line:mbnet.mini:3.0.2:*:*:*:*:*:*:*",
"versionStartIncluding": "3.0.2",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:helmholz:rex200_250:*:*:*:*:*:*:*:*",
"versionEndIncluding": "8.4.4",
"versionStartIncluding": "0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:helmholz:rex100:*:*:*:*:*:*:*:*",
"versionEndIncluding": "3.0.2",
"versionStartIncluding": "0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:helmholz:rex200_250:8.4.4:*:*:*:*:*:*:*",
"versionStartIncluding": "8.4.4",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:helmholz:rex100:3.0.2:*:*:*:*:*:*:*",
"versionStartIncluding": "3.0.2",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Moritz Abrell from SySS GmbH"
},
{
"lang": "en",
"type": "finder",
"value": "Christian Z\u00e4ske from SySS GmbH"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eA local attacker can perform a confusion attack on the cfgparser via a specially crafted file on an USB stick leading to code execution. This can result in a total loss of confidentiality, integrity and availability.\u003c/p\u003e"
}
],
"value": "A local attacker can perform a confusion attack on the cfgparser via a specially crafted file on an USB stick leading to code execution. This can result in a total loss of confidentiality, integrity and availability."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 8.4,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-1287",
"description": "CWE-1287 Improper Validation of Specified Type of Input",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-05-27T08:06:21.815Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://www.certvde.com/en/advisories/VDE-2026-054/"
}
],
"source": {
"advisory": "VDE-2026-054",
"defect": [
"CERT@VDE#642070"
],
"discovery": "UNKNOWN"
},
"title": "Command injection via USB",
"x_generator": {
"engine": "Vulnogram 0.4.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2026-40851",
"datePublished": "2026-05-27T08:06:21.815Z",
"dateReserved": "2026-04-15T09:33:02.614Z",
"dateUpdated": "2026-05-27T11:54:33.819Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2024-45276 (GCVE-0-2024-45276)
Vulnerability from nvd – Published: 2024-10-15 10:28 – Updated: 2025-01-24 06:32
VLAI
Title
MB connect line/Helmholz: tmp directory exposed via webservice
Summary
An unauthenticated remote attacker can get read access to files in the "/tmp" directory due to missing authentication.
Severity
7.5 (High)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-306 - Missing Authentication for Critical Function
Assigner
References
Impacted products
4 products
| Vendor | Product | Version | |
|---|---|---|---|
| MB connect line | mbNET.mini |
Affected:
0.0.0 , ≤ 2.2.13
(semver)
|
|
| Helmholz | REX100 |
Affected:
0.0.0 , ≤ 2.2.13
(semver)
|
|
| mb_connect_line | mbnet.mini |
Affected:
0 , ≤ 2.2.13
(semver)
cpe:2.3:a:mb_connect_line:mbnet.mini:*:*:*:*:*:*:*:* |
|
| helmholz | rex_100_firmware |
Affected:
0 , ≤ 2.2.13
(semver)
cpe:2.3:a:helmholz:rex_100_firmware:*:*:*:*:*:*:*:* |
Date Public
2024-10-15 08:00
Credits
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:mb_connect_line:mbnet.mini:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "mbnet.mini",
"vendor": "mb_connect_line",
"versions": [
{
"lessThanOrEqual": "2.2.13",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"cpes": [
"cpe:2.3:a:helmholz:rex_100_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "rex_100_firmware",
"vendor": "helmholz",
"versions": [
{
"lessThanOrEqual": "2.2.13",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-45276",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-15T13:28:49.058765Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-15T13:30:48.688Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-10-16T17:16:43.319Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "https://www.syss.de/fileadmin/dokumente/Publikationen/Advisories/SYSS-2024-065.txt"
}
],
"title": "CVE Program Container",
"x_generator": {
"engine": "ADPogram 0.0.1"
}
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "mbNET.mini",
"vendor": "MB connect line",
"versions": [
{
"lessThanOrEqual": "2.2.13",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "REX100",
"vendor": "Helmholz",
"versions": [
{
"lessThanOrEqual": "2.2.13",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Moritz Abrell"
},
{
"lang": "en",
"type": "reporter",
"user": "00000000-0000-4000-9000-000000000000",
"value": "SySS GmbH"
}
],
"datePublic": "2024-10-15T08:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "An unauthenticated remote attacker can get read access to files in the \"/tmp\" directory due to missing authentication.\u003cbr\u003e"
}
],
"value": "An unauthenticated remote attacker can get read access to files in the \"/tmp\" directory due to missing authentication."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306 Missing Authentication for Critical Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-01-24T06:32:08.237Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2024-056"
},
{
"url": "https://cert.vde.com/en/advisories/VDE-2024-066"
}
],
"source": {
"advisory": "VDE-2024-056, VDE-2024-066",
"defect": [
"CERT@VDE#641679",
"CERT@VDE#641692"
],
"discovery": "UNKNOWN"
},
"title": "MB connect line/Helmholz: tmp directory exposed via webservice",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2024-45276",
"datePublished": "2024-10-15T10:28:58.559Z",
"dateReserved": "2024-08-26T09:19:01.267Z",
"dateUpdated": "2025-01-24T06:32:08.237Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-45275 (GCVE-0-2024-45275)
Vulnerability from nvd – Published: 2024-10-15 10:28 – Updated: 2024-10-16 17:39
VLAI
Title
MB connect line/Helmholz: Hardcoded user accounts with hard-coded passwords
Summary
The devices contain two hard coded user accounts with hardcoded passwords that allow an unauthenticated remote attacker for full control of the affected devices.
Severity
9.8 (Critical)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-798 - Use of Hard-coded Credentials
Assigner
References
Impacted products
4 products
| Vendor | Product | Version | |
|---|---|---|---|
| MB connect line | mbNET.mini |
Affected:
0.0.0 , ≤ 2.2.13
(semver)
|
|
| Helmholz | REX100 |
Affected:
0.0.0 , ≤ 2.2.13
(semver)
|
|
| mb_connect_line | mbnet.mini |
Affected:
0 , ≤ 2.2.13
(semver)
cpe:2.3:a:mb_connect_line:mbnet.mini:*:*:*:*:*:*:*:* |
|
| helmholz | rex_100_firmware |
Affected:
0 , ≤ 2.2.13
(semver)
cpe:2.3:a:helmholz:rex_100_firmware:*:*:*:*:*:*:*:* |
Date Public
2024-10-15 08:00
Credits
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:mb_connect_line:mbnet.mini:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "mbnet.mini",
"vendor": "mb_connect_line",
"versions": [
{
"lessThanOrEqual": "2.2.13",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"cpes": [
"cpe:2.3:a:helmholz:rex_100_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "rex_100_firmware",
"vendor": "helmholz",
"versions": [
{
"lessThanOrEqual": "2.2.13",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-45275",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-15T13:31:57.475980Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-15T13:33:13.397Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-10-16T17:39:58.106Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "https://www.syss.de/fileadmin/dokumente/Publikationen/Advisories/SYSS-2024-064.txt"
}
],
"title": "CVE Program Container",
"x_generator": {
"engine": "ADPogram 0.0.1"
}
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "mbNET.mini",
"vendor": "MB connect line",
"versions": [
{
"lessThanOrEqual": "2.2.13",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "REX100",
"vendor": "Helmholz",
"versions": [
{
"lessThanOrEqual": "2.2.13",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Moritz Abrell"
},
{
"lang": "en",
"type": "reporter",
"user": "00000000-0000-4000-9000-000000000000",
"value": "SySS GmbH"
}
],
"datePublic": "2024-10-15T08:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The devices contain two hard coded user accounts with hardcoded passwords that allow an unauthenticated remote attacker for full control of the affected devices.\u003cbr\u003e"
}
],
"value": "The devices contain two hard coded user accounts with hardcoded passwords that allow an unauthenticated remote attacker for full control of the affected devices."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-798",
"description": "CWE-798 Use of Hard-coded Credentials",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-10-15T10:28:37.223Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2024-056"
},
{
"url": "https://cert.vde.com/en/advisories/VDE-2024-066"
}
],
"source": {
"advisory": "VDE-2024-056, VDE-2024-066",
"defect": [
"CERT@VDE#641679",
"CERT@VDE#641692"
],
"discovery": "UNKNOWN"
},
"title": "MB connect line/Helmholz: Hardcoded user accounts with hard-coded passwords",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2024-45275",
"datePublished": "2024-10-15T10:28:37.223Z",
"dateReserved": "2024-08-26T09:19:01.266Z",
"dateUpdated": "2024-10-16T17:39:58.106Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-45274 (GCVE-0-2024-45274)
Vulnerability from nvd – Published: 2024-10-15 10:28 – Updated: 2025-11-03 19:30
VLAI
Title
MB connect line/Helmholz: Remote code execution via confnet service
Summary
An unauthenticated remote attacker can execute OS commands via UDP on the device due to missing authentication.
Severity
9.8 (Critical)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-306 - Missing Authentication for Critical Function
Assigner
References
Impacted products
4 products
| Vendor | Product | Version | |
|---|---|---|---|
| MB connect line | mbNET.mini |
Affected:
0.0.0 , ≤ 2.2.13
(semver)
|
|
| Helmholz | REX100 |
Affected:
0.0.0 , ≤ 2.2.13
(semver)
|
|
| mb_connect_line | mbnet.mini |
Affected:
0 , ≤ 2.2.13
(semver)
cpe:2.3:a:mb_connect_line:mbnet.mini:*:*:*:*:*:*:*:* |
|
| helmholz | rex_100_firmware |
Affected:
0 , ≤ 2.2.13
(semver)
cpe:2.3:a:helmholz:rex_100_firmware:*:*:*:*:*:*:*:* |
Date Public
2024-10-15 08:00
Credits
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:mb_connect_line:mbnet.mini:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "mbnet.mini",
"vendor": "mb_connect_line",
"versions": [
{
"lessThanOrEqual": "2.2.13",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"cpes": [
"cpe:2.3:a:helmholz:rex_100_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "rex_100_firmware",
"vendor": "helmholz",
"versions": [
{
"lessThanOrEqual": "2.2.13",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"cpes": [
"cpe:2.3:a:mb_connect_line:mbnet.mini:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "mbnet.mini",
"vendor": "mb_connect_line",
"versions": [
{
"lessThanOrEqual": "2.2.13",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"cpes": [
"cpe:2.3:a:helmholz:rex_100_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "rex_100_firmware",
"vendor": "helmholz",
"versions": [
{
"lessThanOrEqual": "2.2.13",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-45274",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-15T13:33:38.579567Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-15T13:34:58.690Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2025-11-03T19:30:51.547Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "https://www.syss.de/fileadmin/dokumente/Publikationen/Advisories/SYSS-2024-063.txt"
},
{
"url": "http://seclists.org/fulldisclosure/2025/Jul/38"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "mbNET.mini",
"vendor": "MB connect line",
"versions": [
{
"lessThanOrEqual": "2.2.13",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "REX100",
"vendor": "Helmholz",
"versions": [
{
"lessThanOrEqual": "2.2.13",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Moritz Abrell"
},
{
"lang": "en",
"type": "reporter",
"user": "00000000-0000-4000-9000-000000000000",
"value": "SySS GmbH"
}
],
"datePublic": "2024-10-15T08:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "An unauthenticated remote attacker can execute OS commands via UDP on the device due to missing authentication.\u003cbr\u003e"
}
],
"value": "An unauthenticated remote attacker can execute OS commands via UDP on the device due to missing authentication."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306 Missing Authentication for Critical Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-10-15T10:28:16.384Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2024-056"
},
{
"url": "https://cert.vde.com/en/advisories/VDE-2024-066"
}
],
"source": {
"advisory": "VDE-2024-056, VDE-2024-066",
"defect": [
"CERT@VDE#641679",
"CERT@VDE#641692"
],
"discovery": "UNKNOWN"
},
"title": "MB connect line/Helmholz: Remote code execution via confnet service",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2024-45274",
"datePublished": "2024-10-15T10:28:16.384Z",
"dateReserved": "2024-08-26T09:19:01.266Z",
"dateUpdated": "2025-11-03T19:30:51.547Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2024-45273 (GCVE-0-2024-45273)
Vulnerability from nvd – Published: 2024-10-15 10:27 – Updated: 2024-10-16 17:47
VLAI
Title
MB connect line/Helmholz: Weak encryption of configuration file
Summary
An unauthenticated local attacker can decrypt the devices config file and therefore compromise the device due to a weak implementation of the encryption used.
Severity
8.4 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-261 - Weak Encoding for Password
Assigner
References
Impacted products
23 products
| Vendor | Product | Version | |
|---|---|---|---|
| MB connect line | mbNET.mini |
Affected:
0.0.0 , ≤ 2.2.13
(semver)
|
|
| MB connect line | mbNET/mbNET.rokey |
Affected:
0.0.0 , ≤ 8.2.0
(semver)
|
|
| MB connect line | mbNET HW1 |
Affected:
0.0.0 , ≤ 5.1.11
(semver)
|
|
| MB connect line | mbSPIDER |
Affected:
0.0.0 , ≤ 2.6.5
(semver)
|
|
| MB connect line | mbCONNECT24 |
Affected:
0.0.0 , ≤ 2.16.2
(semver)
|
|
| MB connect line | mymbCONNECT24 |
Affected:
0.0.0 , ≤ 2.16.2
(semver)
|
|
| Helmholz | REX100 |
Affected:
0.0.0 , ≤ <= 2.2.13
(semver)
|
|
| Helmholz | REX200/250 |
Affected:
0.0.0 , ≤ <= 8.2.0
(semver)
|
|
| Helmholz | myREX24 V2 |
Affected:
0.0.0 , ≤ <= 2.16.2
(semver)
|
|
| Helmholz | myREX24.virtual |
Affected:
0.0.0 , ≤ <= 2.16.2
(semver)
|
|
| Helmholz | REX300 |
Affected:
0.0.0 , ≤ <= 5.1.11
(semver)
|
|
| mb_connect_line | mbnet.mini |
Affected:
0 , ≤ 2.2.13
(semver)
cpe:2.3:a:mb_connect_line:mbnet.mini:*:*:*:*:*:*:*:* |
|
| mbconnectline | mbnet_mbnet.rokey |
Affected:
0 , ≤ 8.2.0
(semver)
cpe:2.3:a:mbconnectline:mbnet_mbnet.rokey:*:*:*:*:*:*:*:* |
|
| mbconnectline | mbnet_hw1 |
Affected:
0 , ≤ 5.1.11
(semver)
cpe:2.3:a:mbconnectline:mbnet_hw1:*:*:*:*:*:*:*:* |
|
| mbconnectline | mbspider |
Affected:
0 , ≤ 2.6.5
(semver)
cpe:2.3:a:mbconnectline:mbspider:*:*:*:*:*:*:*:* |
|
| mbconnectline | mbconnect24 |
Affected:
0 , ≤ 2.16.2
(semver)
cpe:2.3:a:mbconnectline:mbconnect24:-:*:*:*:*:*:*:* |
|
| mbconnectline | mymbconnect24 |
Affected:
0 , ≤ 2.16.2
(semver)
cpe:2.3:a:mbconnectline:mymbconnect24:-:*:*:*:*:*:*:* |
|
| helmholz | rex100 |
Affected:
0 , ≤ 2.2.13
(semver)
cpe:2.3:a:helmholz:rex100:*:*:*:*:*:*:*:* |
|
| helmholz | rex_200 |
Affected:
0 , ≤ 8.2.0
(semver)
cpe:2.3:h:helmholz:rex_200:-:*:*:*:*:*:*:* |
|
| helmholz | rex250 |
Affected:
0 , ≤ 8.2.0
(semver)
cpe:2.3:a:helmholz:rex250:*:*:*:*:*:*:*:* |
|
| helmholz | myrex24_v2 |
Affected:
0 , ≤ 2.16.2
(semver)
cpe:2.3:a:helmholz:myrex24_v2:*:*:*:*:*:*:*:* |
|
| helmholz | myrex24.virtual |
Affected:
0 , ≤ 2.16.2
(semver)
cpe:2.3:a:helmholz:myrex24.virtual:*:*:*:*:*:*:*:* |
|
| helmholz | rex300 |
Affected:
0 , ≤ 5.1.11
(semver)
cpe:2.3:a:helmholz:rex300:*:*:*:*:*:*:*:* |
Date Public
2024-10-15 08:00
Credits
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:mb_connect_line:mbnet.mini:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "mbnet.mini",
"vendor": "mb_connect_line",
"versions": [
{
"lessThanOrEqual": "2.2.13",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"cpes": [
"cpe:2.3:a:mbconnectline:mbnet_mbnet.rokey:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "mbnet_mbnet.rokey",
"vendor": "mbconnectline",
"versions": [
{
"lessThanOrEqual": "8.2.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"cpes": [
"cpe:2.3:a:mbconnectline:mbnet_hw1:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "mbnet_hw1",
"vendor": "mbconnectline",
"versions": [
{
"lessThanOrEqual": "5.1.11",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"cpes": [
"cpe:2.3:a:mbconnectline:mbspider:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "mbspider",
"vendor": "mbconnectline",
"versions": [
{
"lessThanOrEqual": "2.6.5",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"cpes": [
"cpe:2.3:a:mbconnectline:mbconnect24:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "mbconnect24",
"vendor": "mbconnectline",
"versions": [
{
"lessThanOrEqual": "2.16.2",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"cpes": [
"cpe:2.3:a:mbconnectline:mymbconnect24:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "mymbconnect24",
"vendor": "mbconnectline",
"versions": [
{
"lessThanOrEqual": "2.16.2",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"cpes": [
"cpe:2.3:a:helmholz:rex100:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "rex100",
"vendor": "helmholz",
"versions": [
{
"lessThanOrEqual": "2.2.13",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"cpes": [
"cpe:2.3:h:helmholz:rex_200:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "rex_200",
"vendor": "helmholz",
"versions": [
{
"lessThanOrEqual": "8.2.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"cpes": [
"cpe:2.3:a:helmholz:rex250:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "rex250",
"vendor": "helmholz",
"versions": [
{
"lessThanOrEqual": "8.2.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"cpes": [
"cpe:2.3:a:helmholz:myrex24_v2:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "myrex24_v2",
"vendor": "helmholz",
"versions": [
{
"lessThanOrEqual": "2.16.2",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"cpes": [
"cpe:2.3:a:helmholz:myrex24.virtual:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "myrex24.virtual",
"vendor": "helmholz",
"versions": [
{
"lessThanOrEqual": "2.16.2",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"cpes": [
"cpe:2.3:a:helmholz:rex300:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "rex300",
"vendor": "helmholz",
"versions": [
{
"lessThanOrEqual": "5.1.11",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-45273",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-15T18:22:26.955543Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-15T18:31:20.013Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-10-16T17:47:04.737Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "https://www.syss.de/fileadmin/dokumente/Publikationen/Advisories/SYSS-2024-062.txt"
}
],
"title": "CVE Program Container",
"x_generator": {
"engine": "ADPogram 0.0.1"
}
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "mbNET.mini",
"vendor": "MB connect line",
"versions": [
{
"lessThanOrEqual": "2.2.13",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "mbNET/mbNET.rokey",
"vendor": "MB connect line",
"versions": [
{
"lessThanOrEqual": "8.2.0",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "mbNET HW1",
"vendor": "MB connect line",
"versions": [
{
"lessThanOrEqual": "5.1.11",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "mbSPIDER",
"vendor": "MB connect line",
"versions": [
{
"lessThanOrEqual": "2.6.5",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "mbCONNECT24",
"vendor": "MB connect line",
"versions": [
{
"lessThanOrEqual": "2.16.2",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "mymbCONNECT24",
"vendor": "MB connect line",
"versions": [
{
"lessThanOrEqual": "2.16.2",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "REX100",
"vendor": "Helmholz",
"versions": [
{
"lessThanOrEqual": "\u003c= 2.2.13",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "REX200/250",
"vendor": "Helmholz",
"versions": [
{
"lessThanOrEqual": "\u003c= 8.2.0",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "myREX24 V2",
"vendor": "Helmholz",
"versions": [
{
"lessThanOrEqual": "\u003c= 2.16.2",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "myREX24.virtual",
"vendor": "Helmholz",
"versions": [
{
"lessThanOrEqual": "\u003c= 2.16.2",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "REX300",
"vendor": "Helmholz",
"versions": [
{
"lessThanOrEqual": "\u003c= 5.1.11",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Moritz Abrell"
},
{
"lang": "en",
"type": "reporter",
"user": "00000000-0000-4000-9000-000000000000",
"value": "SySS GmbH"
}
],
"datePublic": "2024-10-15T08:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "An unauthenticated local attacker can decrypt the devices config file and therefore compromise the device due to a weak implementation of the encryption used.\u003cbr\u003e"
}
],
"value": "An unauthenticated local attacker can decrypt the devices config file and therefore compromise the device due to a weak implementation of the encryption used."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 8.4,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-261",
"description": "CWE-261: Weak Encoding for Password",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-10-15T10:27:52.208Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2024-056"
},
{
"url": "https://cert.vde.com/en/advisories/VDE-2024-066"
},
{
"url": "https://cert.vde.com/en/advisories/VDE-2024-068"
},
{
"url": "https://cert.vde.com/en/advisories/VDE-2024-069"
}
],
"source": {
"advisory": "VDE-2024-056, VDE-2024-066, VDE-2024-068, VDE-2024-069",
"defect": [
"CERT@VDE#641679",
"CERT@VDE#641695",
"CERT@VDE#641692",
"CERT@VDE#641696"
],
"discovery": "UNKNOWN"
},
"title": "MB connect line/Helmholz: Weak encryption of configuration file",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2024-45273",
"datePublished": "2024-10-15T10:27:52.208Z",
"dateReserved": "2024-08-26T09:19:01.266Z",
"dateUpdated": "2024-10-16T17:47:04.737Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-45271 (GCVE-0-2024-45271)
Vulnerability from nvd – Published: 2024-10-15 10:27 – Updated: 2025-08-26 14:14
VLAI
Title
MB connect line/Helmholz: Remote code execution due to improper input validation
Summary
An unauthenticated local attacker can gain admin privileges by deploying a config file due to improper input validation.
Severity
8.4 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-94 - Improper Control of Generation of Code ('Code Injection')
Assigner
References
Impacted products
4 products
| Vendor | Product | Version | |
|---|---|---|---|
| MB connect line | mbNET.mini |
Affected:
0.0.0 , ≤ 2.2.13
(semver)
|
|
| Helmholz | REX100 |
Affected:
0.0.0 , ≤ 2.2.13
(semver)
|
|
| mb_connect_line | mbnet.mini |
Affected:
0 , ≤ 2.2.13
(semver)
cpe:2.3:a:mb_connect_line:mbnet.mini:*:*:*:*:*:*:*:* |
|
| rex100 | helmholz |
Affected:
0 , ≤ 2.2.13
(semver)
cpe:2.3:a:rex100:helmholz:*:*:*:*:*:*:*:* |
Date Public
2024-10-15 08:00
Credits
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:mb_connect_line:mbnet.mini:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "mbnet.mini",
"vendor": "mb_connect_line",
"versions": [
{
"lessThanOrEqual": "2.2.13",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"cpes": [
"cpe:2.3:a:rex100:helmholz:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "helmholz",
"vendor": "rex100",
"versions": [
{
"lessThanOrEqual": "2.2.13",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-45271",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-15T13:12:42.565246Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-08-26T14:14:12.044Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-10-16T17:49:30.446Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "https://www.syss.de/fileadmin/dokumente/Publikationen/Advisories/SYSS-2024-059.txt"
}
],
"title": "CVE Program Container",
"x_generator": {
"engine": "ADPogram 0.0.1"
}
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "mbNET.mini",
"vendor": "MB connect line",
"versions": [
{
"lessThanOrEqual": "2.2.13",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "REX100",
"vendor": "Helmholz",
"versions": [
{
"lessThanOrEqual": "2.2.13",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Moritz Abrell"
},
{
"lang": "en",
"type": "reporter",
"user": "00000000-0000-4000-9000-000000000000",
"value": "SySS GmbH"
}
],
"datePublic": "2024-10-15T08:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "An unauthenticated local attacker can gain admin privileges by deploying a config file due to improper input validation.\u003cbr\u003e"
}
],
"value": "An unauthenticated local attacker can gain admin privileges by deploying a config file due to improper input validation."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 8.4,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-94",
"description": "CWE-94 Improper Control of Generation of Code (\u0027Code Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-08-22T06:55:23.671Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2024-056"
},
{
"url": "https://cert.vde.com/en/advisories/VDE-2024-066"
}
],
"source": {
"advisory": "VDE-2024-056, VDE-2024-066",
"defect": [
"CERT@VDE#641679",
"CERT@VDE#641692"
],
"discovery": "UNKNOWN"
},
"title": "MB connect line/Helmholz: Remote code execution due to improper input validation",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2024-45271",
"datePublished": "2024-10-15T10:27:06.004Z",
"dateReserved": "2024-08-26T09:19:01.266Z",
"dateUpdated": "2025-08-26T14:14:12.044Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2026-40852 (GCVE-0-2026-40852)
Vulnerability from cvelistv5 – Published: 2026-05-27 08:06 – Updated: 2026-05-27 11:54
VLAI
Title
Command injection via malicious configuration
Summary
A highly authenticated attacker can alter the config generator injecting a payload into future created configurations. The device is not correctly checking this configuration value before passing it to an system execute leading to code execution. This can result in a total loss of confidentiality, integrity and availability.
Severity
7.2 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
1 reference
Impacted products
8 products
| Vendor | Product | Version | |
|---|---|---|---|
| MB connect line | mbNET/mbNET.rokey |
Affected:
0.0.0 , ≤ 8.4.4
(semver)
|
|
| MB connect line | mbNET.mini |
Affected:
0.0.0 , ≤ 3.0.2
(semver)
|
|
| MB connect line | mbNET/mbNET.rokey |
Affected:
8.4.4
|
|
| MB connect line | mbNET.mini |
Affected:
3.0.2
|
|
| Helmholz | REX200/250 |
Affected:
0.0.0 , ≤ 8.4.4
(semver)
|
|
| Helmholz | REX100 |
Affected:
0.0.0 , ≤ 3.0.2
(semver)
|
|
| Helmholz | REX200/250 |
Affected:
8.4.4
|
|
| Helmholz | REX100 |
Affected:
3.0.2
|
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-40852",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-05-27T11:44:33.329985Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-05-27T11:54:17.274Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "mbNET/mbNET.rokey",
"vendor": "MB connect line",
"versions": [
{
"lessThanOrEqual": "8.4.4",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "mbNET.mini",
"vendor": "MB connect line",
"versions": [
{
"lessThanOrEqual": "3.0.2",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "mbNET/mbNET.rokey",
"vendor": "MB connect line",
"versions": [
{
"status": "affected",
"version": "8.4.4"
}
]
},
{
"defaultStatus": "unaffected",
"product": "mbNET.mini",
"vendor": "MB connect line",
"versions": [
{
"status": "affected",
"version": "3.0.2"
}
]
},
{
"defaultStatus": "unaffected",
"product": "REX200/250",
"vendor": "Helmholz",
"versions": [
{
"lessThanOrEqual": "8.4.4",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "REX100",
"vendor": "Helmholz",
"versions": [
{
"lessThanOrEqual": "3.0.2",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "REX200/250",
"vendor": "Helmholz",
"versions": [
{
"status": "affected",
"version": "8.4.4"
}
]
},
{
"defaultStatus": "unaffected",
"product": "REX100",
"vendor": "Helmholz",
"versions": [
{
"status": "affected",
"version": "3.0.2"
}
]
}
],
"cpeApplicability": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:mb_connect_line:mbnet_mbnet.rokey:*:*:*:*:*:*:*:*",
"versionEndIncluding": "8.4.4",
"versionStartIncluding": "0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:mb_connect_line:mbnet.mini:*:*:*:*:*:*:*:*",
"versionEndIncluding": "3.0.2",
"versionStartIncluding": "0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:mb_connect_line:mbnet:8.4.4:*:*:*:*:*:*:*",
"versionStartIncluding": "8.4.4",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:mb_connect_line:mbnet.mini:3.0.2:*:*:*:*:*:*:*",
"versionStartIncluding": "3.0.2",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:helmholz:rex200_250:*:*:*:*:*:*:*:*",
"versionEndIncluding": "8.4.4",
"versionStartIncluding": "0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:helmholz:rex100:*:*:*:*:*:*:*:*",
"versionEndIncluding": "3.0.2",
"versionStartIncluding": "0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:helmholz:rex200_250:8.4.4:*:*:*:*:*:*:*",
"versionStartIncluding": "8.4.4",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:helmholz:rex100:3.0.2:*:*:*:*:*:*:*",
"versionStartIncluding": "3.0.2",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Moritz Abrell from SySS GmbH"
},
{
"lang": "en",
"type": "finder",
"value": "Christian Z\u00e4ske from SySS GmbH"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eA highly authenticated attacker can alter the config generator injecting a payload into future created configurations. The device is not correctly checking this configuration value before passing it to an system execute leading to code execution. This can result in a total loss of confidentiality, integrity and availability.\u003c/p\u003e"
}
],
"value": "A highly authenticated attacker can alter the config generator injecting a payload into future created configurations. The device is not correctly checking this configuration value before passing it to an system execute leading to code execution. This can result in a total loss of confidentiality, integrity and availability."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-05-27T08:06:36.875Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://www.certvde.com/en/advisories/VDE-2026-054/"
}
],
"source": {
"advisory": "VDE-2026-054",
"defect": [
"CERT@VDE#642070"
],
"discovery": "UNKNOWN"
},
"title": "Command injection via malicious configuration",
"x_generator": {
"engine": "Vulnogram 0.4.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2026-40852",
"datePublished": "2026-05-27T08:06:36.875Z",
"dateReserved": "2026-04-15T09:33:02.614Z",
"dateUpdated": "2026-05-27T11:54:17.274Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-40851 (GCVE-0-2026-40851)
Vulnerability from cvelistv5 – Published: 2026-05-27 08:06 – Updated: 2026-05-27 11:54
VLAI
Title
Command injection via USB
Summary
A local attacker can perform a confusion attack on the cfgparser via a specially crafted file on an USB stick leading to code execution. This can result in a total loss of confidentiality, integrity and availability.
Severity
8.4 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-1287 - Improper Validation of Specified Type of Input
Assigner
References
1 reference
Impacted products
8 products
| Vendor | Product | Version | |
|---|---|---|---|
| MB connect line | mbNET/mbNET.rokey |
Affected:
0.0.0 , ≤ 8.4.4
(semver)
|
|
| MB connect line | mbNET.mini |
Affected:
0.0.0 , ≤ 3.0.2
(semver)
|
|
| MB connect line | mbNET/mbNET.rokey |
Affected:
8.4.4
|
|
| MB connect line | mbNET.mini |
Affected:
3.0.2
|
|
| Helmholz | REX200/250 |
Affected:
0.0.0 , ≤ 8.4.4
(semver)
|
|
| Helmholz | REX100 |
Affected:
0.0.0 , ≤ 3.0.2
(semver)
|
|
| Helmholz | REX200/250 |
Affected:
8.4.4
|
|
| Helmholz | REX100 |
Affected:
3.0.2
|
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-40851",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-05-27T11:44:44.253548Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-05-27T11:54:33.819Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "mbNET/mbNET.rokey",
"vendor": "MB connect line",
"versions": [
{
"lessThanOrEqual": "8.4.4",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "mbNET.mini",
"vendor": "MB connect line",
"versions": [
{
"lessThanOrEqual": "3.0.2",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "mbNET/mbNET.rokey",
"vendor": "MB connect line",
"versions": [
{
"status": "affected",
"version": "8.4.4"
}
]
},
{
"defaultStatus": "unaffected",
"product": "mbNET.mini",
"vendor": "MB connect line",
"versions": [
{
"status": "affected",
"version": "3.0.2"
}
]
},
{
"defaultStatus": "unaffected",
"product": "REX200/250",
"vendor": "Helmholz",
"versions": [
{
"lessThanOrEqual": "8.4.4",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "REX100",
"vendor": "Helmholz",
"versions": [
{
"lessThanOrEqual": "3.0.2",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "REX200/250",
"vendor": "Helmholz",
"versions": [
{
"status": "affected",
"version": "8.4.4"
}
]
},
{
"defaultStatus": "unaffected",
"product": "REX100",
"vendor": "Helmholz",
"versions": [
{
"status": "affected",
"version": "3.0.2"
}
]
}
],
"cpeApplicability": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:mb_connect_line:mbnet_mbnet.rokey:*:*:*:*:*:*:*:*",
"versionEndIncluding": "8.4.4",
"versionStartIncluding": "0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:mb_connect_line:mbnet.mini:*:*:*:*:*:*:*:*",
"versionEndIncluding": "3.0.2",
"versionStartIncluding": "0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:mb_connect_line:mbnet:8.4.4:*:*:*:*:*:*:*",
"versionStartIncluding": "8.4.4",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:mb_connect_line:mbnet.mini:3.0.2:*:*:*:*:*:*:*",
"versionStartIncluding": "3.0.2",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:helmholz:rex200_250:*:*:*:*:*:*:*:*",
"versionEndIncluding": "8.4.4",
"versionStartIncluding": "0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:helmholz:rex100:*:*:*:*:*:*:*:*",
"versionEndIncluding": "3.0.2",
"versionStartIncluding": "0.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:helmholz:rex200_250:8.4.4:*:*:*:*:*:*:*",
"versionStartIncluding": "8.4.4",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:helmholz:rex100:3.0.2:*:*:*:*:*:*:*",
"versionStartIncluding": "3.0.2",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Moritz Abrell from SySS GmbH"
},
{
"lang": "en",
"type": "finder",
"value": "Christian Z\u00e4ske from SySS GmbH"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eA local attacker can perform a confusion attack on the cfgparser via a specially crafted file on an USB stick leading to code execution. This can result in a total loss of confidentiality, integrity and availability.\u003c/p\u003e"
}
],
"value": "A local attacker can perform a confusion attack on the cfgparser via a specially crafted file on an USB stick leading to code execution. This can result in a total loss of confidentiality, integrity and availability."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 8.4,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-1287",
"description": "CWE-1287 Improper Validation of Specified Type of Input",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-05-27T08:06:21.815Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://www.certvde.com/en/advisories/VDE-2026-054/"
}
],
"source": {
"advisory": "VDE-2026-054",
"defect": [
"CERT@VDE#642070"
],
"discovery": "UNKNOWN"
},
"title": "Command injection via USB",
"x_generator": {
"engine": "Vulnogram 0.4.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2026-40851",
"datePublished": "2026-05-27T08:06:21.815Z",
"dateReserved": "2026-04-15T09:33:02.614Z",
"dateUpdated": "2026-05-27T11:54:33.819Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2024-45276 (GCVE-0-2024-45276)
Vulnerability from cvelistv5 – Published: 2024-10-15 10:28 – Updated: 2025-01-24 06:32
VLAI
Title
MB connect line/Helmholz: tmp directory exposed via webservice
Summary
An unauthenticated remote attacker can get read access to files in the "/tmp" directory due to missing authentication.
Severity
7.5 (High)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-306 - Missing Authentication for Critical Function
Assigner
References
Impacted products
4 products
| Vendor | Product | Version | |
|---|---|---|---|
| MB connect line | mbNET.mini |
Affected:
0.0.0 , ≤ 2.2.13
(semver)
|
|
| Helmholz | REX100 |
Affected:
0.0.0 , ≤ 2.2.13
(semver)
|
|
| mb_connect_line | mbnet.mini |
Affected:
0 , ≤ 2.2.13
(semver)
cpe:2.3:a:mb_connect_line:mbnet.mini:*:*:*:*:*:*:*:* |
|
| helmholz | rex_100_firmware |
Affected:
0 , ≤ 2.2.13
(semver)
cpe:2.3:a:helmholz:rex_100_firmware:*:*:*:*:*:*:*:* |
Date Public
2024-10-15 08:00
Credits
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:mb_connect_line:mbnet.mini:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "mbnet.mini",
"vendor": "mb_connect_line",
"versions": [
{
"lessThanOrEqual": "2.2.13",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"cpes": [
"cpe:2.3:a:helmholz:rex_100_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "rex_100_firmware",
"vendor": "helmholz",
"versions": [
{
"lessThanOrEqual": "2.2.13",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-45276",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-15T13:28:49.058765Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-15T13:30:48.688Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-10-16T17:16:43.319Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "https://www.syss.de/fileadmin/dokumente/Publikationen/Advisories/SYSS-2024-065.txt"
}
],
"title": "CVE Program Container",
"x_generator": {
"engine": "ADPogram 0.0.1"
}
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "mbNET.mini",
"vendor": "MB connect line",
"versions": [
{
"lessThanOrEqual": "2.2.13",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "REX100",
"vendor": "Helmholz",
"versions": [
{
"lessThanOrEqual": "2.2.13",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Moritz Abrell"
},
{
"lang": "en",
"type": "reporter",
"user": "00000000-0000-4000-9000-000000000000",
"value": "SySS GmbH"
}
],
"datePublic": "2024-10-15T08:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "An unauthenticated remote attacker can get read access to files in the \"/tmp\" directory due to missing authentication.\u003cbr\u003e"
}
],
"value": "An unauthenticated remote attacker can get read access to files in the \"/tmp\" directory due to missing authentication."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306 Missing Authentication for Critical Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-01-24T06:32:08.237Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2024-056"
},
{
"url": "https://cert.vde.com/en/advisories/VDE-2024-066"
}
],
"source": {
"advisory": "VDE-2024-056, VDE-2024-066",
"defect": [
"CERT@VDE#641679",
"CERT@VDE#641692"
],
"discovery": "UNKNOWN"
},
"title": "MB connect line/Helmholz: tmp directory exposed via webservice",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2024-45276",
"datePublished": "2024-10-15T10:28:58.559Z",
"dateReserved": "2024-08-26T09:19:01.267Z",
"dateUpdated": "2025-01-24T06:32:08.237Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-45275 (GCVE-0-2024-45275)
Vulnerability from cvelistv5 – Published: 2024-10-15 10:28 – Updated: 2024-10-16 17:39
VLAI
Title
MB connect line/Helmholz: Hardcoded user accounts with hard-coded passwords
Summary
The devices contain two hard coded user accounts with hardcoded passwords that allow an unauthenticated remote attacker for full control of the affected devices.
Severity
9.8 (Critical)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-798 - Use of Hard-coded Credentials
Assigner
References
Impacted products
4 products
| Vendor | Product | Version | |
|---|---|---|---|
| MB connect line | mbNET.mini |
Affected:
0.0.0 , ≤ 2.2.13
(semver)
|
|
| Helmholz | REX100 |
Affected:
0.0.0 , ≤ 2.2.13
(semver)
|
|
| mb_connect_line | mbnet.mini |
Affected:
0 , ≤ 2.2.13
(semver)
cpe:2.3:a:mb_connect_line:mbnet.mini:*:*:*:*:*:*:*:* |
|
| helmholz | rex_100_firmware |
Affected:
0 , ≤ 2.2.13
(semver)
cpe:2.3:a:helmholz:rex_100_firmware:*:*:*:*:*:*:*:* |
Date Public
2024-10-15 08:00
Credits
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:mb_connect_line:mbnet.mini:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "mbnet.mini",
"vendor": "mb_connect_line",
"versions": [
{
"lessThanOrEqual": "2.2.13",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"cpes": [
"cpe:2.3:a:helmholz:rex_100_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "rex_100_firmware",
"vendor": "helmholz",
"versions": [
{
"lessThanOrEqual": "2.2.13",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-45275",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-15T13:31:57.475980Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-15T13:33:13.397Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-10-16T17:39:58.106Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "https://www.syss.de/fileadmin/dokumente/Publikationen/Advisories/SYSS-2024-064.txt"
}
],
"title": "CVE Program Container",
"x_generator": {
"engine": "ADPogram 0.0.1"
}
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "mbNET.mini",
"vendor": "MB connect line",
"versions": [
{
"lessThanOrEqual": "2.2.13",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "REX100",
"vendor": "Helmholz",
"versions": [
{
"lessThanOrEqual": "2.2.13",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Moritz Abrell"
},
{
"lang": "en",
"type": "reporter",
"user": "00000000-0000-4000-9000-000000000000",
"value": "SySS GmbH"
}
],
"datePublic": "2024-10-15T08:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The devices contain two hard coded user accounts with hardcoded passwords that allow an unauthenticated remote attacker for full control of the affected devices.\u003cbr\u003e"
}
],
"value": "The devices contain two hard coded user accounts with hardcoded passwords that allow an unauthenticated remote attacker for full control of the affected devices."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-798",
"description": "CWE-798 Use of Hard-coded Credentials",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-10-15T10:28:37.223Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2024-056"
},
{
"url": "https://cert.vde.com/en/advisories/VDE-2024-066"
}
],
"source": {
"advisory": "VDE-2024-056, VDE-2024-066",
"defect": [
"CERT@VDE#641679",
"CERT@VDE#641692"
],
"discovery": "UNKNOWN"
},
"title": "MB connect line/Helmholz: Hardcoded user accounts with hard-coded passwords",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2024-45275",
"datePublished": "2024-10-15T10:28:37.223Z",
"dateReserved": "2024-08-26T09:19:01.266Z",
"dateUpdated": "2024-10-16T17:39:58.106Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-45274 (GCVE-0-2024-45274)
Vulnerability from cvelistv5 – Published: 2024-10-15 10:28 – Updated: 2025-11-03 19:30
VLAI
Title
MB connect line/Helmholz: Remote code execution via confnet service
Summary
An unauthenticated remote attacker can execute OS commands via UDP on the device due to missing authentication.
Severity
9.8 (Critical)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-306 - Missing Authentication for Critical Function
Assigner
References
Impacted products
4 products
| Vendor | Product | Version | |
|---|---|---|---|
| MB connect line | mbNET.mini |
Affected:
0.0.0 , ≤ 2.2.13
(semver)
|
|
| Helmholz | REX100 |
Affected:
0.0.0 , ≤ 2.2.13
(semver)
|
|
| mb_connect_line | mbnet.mini |
Affected:
0 , ≤ 2.2.13
(semver)
cpe:2.3:a:mb_connect_line:mbnet.mini:*:*:*:*:*:*:*:* |
|
| helmholz | rex_100_firmware |
Affected:
0 , ≤ 2.2.13
(semver)
cpe:2.3:a:helmholz:rex_100_firmware:*:*:*:*:*:*:*:* |
Date Public
2024-10-15 08:00
Credits
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:mb_connect_line:mbnet.mini:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "mbnet.mini",
"vendor": "mb_connect_line",
"versions": [
{
"lessThanOrEqual": "2.2.13",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"cpes": [
"cpe:2.3:a:helmholz:rex_100_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "rex_100_firmware",
"vendor": "helmholz",
"versions": [
{
"lessThanOrEqual": "2.2.13",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"cpes": [
"cpe:2.3:a:mb_connect_line:mbnet.mini:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "mbnet.mini",
"vendor": "mb_connect_line",
"versions": [
{
"lessThanOrEqual": "2.2.13",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"cpes": [
"cpe:2.3:a:helmholz:rex_100_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "rex_100_firmware",
"vendor": "helmholz",
"versions": [
{
"lessThanOrEqual": "2.2.13",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-45274",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-15T13:33:38.579567Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-15T13:34:58.690Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2025-11-03T19:30:51.547Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "https://www.syss.de/fileadmin/dokumente/Publikationen/Advisories/SYSS-2024-063.txt"
},
{
"url": "http://seclists.org/fulldisclosure/2025/Jul/38"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "mbNET.mini",
"vendor": "MB connect line",
"versions": [
{
"lessThanOrEqual": "2.2.13",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "REX100",
"vendor": "Helmholz",
"versions": [
{
"lessThanOrEqual": "2.2.13",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Moritz Abrell"
},
{
"lang": "en",
"type": "reporter",
"user": "00000000-0000-4000-9000-000000000000",
"value": "SySS GmbH"
}
],
"datePublic": "2024-10-15T08:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "An unauthenticated remote attacker can execute OS commands via UDP on the device due to missing authentication.\u003cbr\u003e"
}
],
"value": "An unauthenticated remote attacker can execute OS commands via UDP on the device due to missing authentication."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306 Missing Authentication for Critical Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-10-15T10:28:16.384Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2024-056"
},
{
"url": "https://cert.vde.com/en/advisories/VDE-2024-066"
}
],
"source": {
"advisory": "VDE-2024-056, VDE-2024-066",
"defect": [
"CERT@VDE#641679",
"CERT@VDE#641692"
],
"discovery": "UNKNOWN"
},
"title": "MB connect line/Helmholz: Remote code execution via confnet service",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2024-45274",
"datePublished": "2024-10-15T10:28:16.384Z",
"dateReserved": "2024-08-26T09:19:01.266Z",
"dateUpdated": "2025-11-03T19:30:51.547Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2024-45273 (GCVE-0-2024-45273)
Vulnerability from cvelistv5 – Published: 2024-10-15 10:27 – Updated: 2024-10-16 17:47
VLAI
Title
MB connect line/Helmholz: Weak encryption of configuration file
Summary
An unauthenticated local attacker can decrypt the devices config file and therefore compromise the device due to a weak implementation of the encryption used.
Severity
8.4 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-261 - Weak Encoding for Password
Assigner
References
Impacted products
23 products
| Vendor | Product | Version | |
|---|---|---|---|
| MB connect line | mbNET.mini |
Affected:
0.0.0 , ≤ 2.2.13
(semver)
|
|
| MB connect line | mbNET/mbNET.rokey |
Affected:
0.0.0 , ≤ 8.2.0
(semver)
|
|
| MB connect line | mbNET HW1 |
Affected:
0.0.0 , ≤ 5.1.11
(semver)
|
|
| MB connect line | mbSPIDER |
Affected:
0.0.0 , ≤ 2.6.5
(semver)
|
|
| MB connect line | mbCONNECT24 |
Affected:
0.0.0 , ≤ 2.16.2
(semver)
|
|
| MB connect line | mymbCONNECT24 |
Affected:
0.0.0 , ≤ 2.16.2
(semver)
|
|
| Helmholz | REX100 |
Affected:
0.0.0 , ≤ <= 2.2.13
(semver)
|
|
| Helmholz | REX200/250 |
Affected:
0.0.0 , ≤ <= 8.2.0
(semver)
|
|
| Helmholz | myREX24 V2 |
Affected:
0.0.0 , ≤ <= 2.16.2
(semver)
|
|
| Helmholz | myREX24.virtual |
Affected:
0.0.0 , ≤ <= 2.16.2
(semver)
|
|
| Helmholz | REX300 |
Affected:
0.0.0 , ≤ <= 5.1.11
(semver)
|
|
| mb_connect_line | mbnet.mini |
Affected:
0 , ≤ 2.2.13
(semver)
cpe:2.3:a:mb_connect_line:mbnet.mini:*:*:*:*:*:*:*:* |
|
| mbconnectline | mbnet_mbnet.rokey |
Affected:
0 , ≤ 8.2.0
(semver)
cpe:2.3:a:mbconnectline:mbnet_mbnet.rokey:*:*:*:*:*:*:*:* |
|
| mbconnectline | mbnet_hw1 |
Affected:
0 , ≤ 5.1.11
(semver)
cpe:2.3:a:mbconnectline:mbnet_hw1:*:*:*:*:*:*:*:* |
|
| mbconnectline | mbspider |
Affected:
0 , ≤ 2.6.5
(semver)
cpe:2.3:a:mbconnectline:mbspider:*:*:*:*:*:*:*:* |
|
| mbconnectline | mbconnect24 |
Affected:
0 , ≤ 2.16.2
(semver)
cpe:2.3:a:mbconnectline:mbconnect24:-:*:*:*:*:*:*:* |
|
| mbconnectline | mymbconnect24 |
Affected:
0 , ≤ 2.16.2
(semver)
cpe:2.3:a:mbconnectline:mymbconnect24:-:*:*:*:*:*:*:* |
|
| helmholz | rex100 |
Affected:
0 , ≤ 2.2.13
(semver)
cpe:2.3:a:helmholz:rex100:*:*:*:*:*:*:*:* |
|
| helmholz | rex_200 |
Affected:
0 , ≤ 8.2.0
(semver)
cpe:2.3:h:helmholz:rex_200:-:*:*:*:*:*:*:* |
|
| helmholz | rex250 |
Affected:
0 , ≤ 8.2.0
(semver)
cpe:2.3:a:helmholz:rex250:*:*:*:*:*:*:*:* |
|
| helmholz | myrex24_v2 |
Affected:
0 , ≤ 2.16.2
(semver)
cpe:2.3:a:helmholz:myrex24_v2:*:*:*:*:*:*:*:* |
|
| helmholz | myrex24.virtual |
Affected:
0 , ≤ 2.16.2
(semver)
cpe:2.3:a:helmholz:myrex24.virtual:*:*:*:*:*:*:*:* |
|
| helmholz | rex300 |
Affected:
0 , ≤ 5.1.11
(semver)
cpe:2.3:a:helmholz:rex300:*:*:*:*:*:*:*:* |
Date Public
2024-10-15 08:00
Credits
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:mb_connect_line:mbnet.mini:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "mbnet.mini",
"vendor": "mb_connect_line",
"versions": [
{
"lessThanOrEqual": "2.2.13",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"cpes": [
"cpe:2.3:a:mbconnectline:mbnet_mbnet.rokey:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "mbnet_mbnet.rokey",
"vendor": "mbconnectline",
"versions": [
{
"lessThanOrEqual": "8.2.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"cpes": [
"cpe:2.3:a:mbconnectline:mbnet_hw1:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "mbnet_hw1",
"vendor": "mbconnectline",
"versions": [
{
"lessThanOrEqual": "5.1.11",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"cpes": [
"cpe:2.3:a:mbconnectline:mbspider:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "mbspider",
"vendor": "mbconnectline",
"versions": [
{
"lessThanOrEqual": "2.6.5",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"cpes": [
"cpe:2.3:a:mbconnectline:mbconnect24:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "mbconnect24",
"vendor": "mbconnectline",
"versions": [
{
"lessThanOrEqual": "2.16.2",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"cpes": [
"cpe:2.3:a:mbconnectline:mymbconnect24:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "mymbconnect24",
"vendor": "mbconnectline",
"versions": [
{
"lessThanOrEqual": "2.16.2",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"cpes": [
"cpe:2.3:a:helmholz:rex100:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "rex100",
"vendor": "helmholz",
"versions": [
{
"lessThanOrEqual": "2.2.13",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"cpes": [
"cpe:2.3:h:helmholz:rex_200:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "rex_200",
"vendor": "helmholz",
"versions": [
{
"lessThanOrEqual": "8.2.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"cpes": [
"cpe:2.3:a:helmholz:rex250:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "rex250",
"vendor": "helmholz",
"versions": [
{
"lessThanOrEqual": "8.2.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"cpes": [
"cpe:2.3:a:helmholz:myrex24_v2:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "myrex24_v2",
"vendor": "helmholz",
"versions": [
{
"lessThanOrEqual": "2.16.2",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"cpes": [
"cpe:2.3:a:helmholz:myrex24.virtual:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "myrex24.virtual",
"vendor": "helmholz",
"versions": [
{
"lessThanOrEqual": "2.16.2",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"cpes": [
"cpe:2.3:a:helmholz:rex300:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "rex300",
"vendor": "helmholz",
"versions": [
{
"lessThanOrEqual": "5.1.11",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-45273",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-15T18:22:26.955543Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-15T18:31:20.013Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-10-16T17:47:04.737Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "https://www.syss.de/fileadmin/dokumente/Publikationen/Advisories/SYSS-2024-062.txt"
}
],
"title": "CVE Program Container",
"x_generator": {
"engine": "ADPogram 0.0.1"
}
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "mbNET.mini",
"vendor": "MB connect line",
"versions": [
{
"lessThanOrEqual": "2.2.13",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "mbNET/mbNET.rokey",
"vendor": "MB connect line",
"versions": [
{
"lessThanOrEqual": "8.2.0",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "mbNET HW1",
"vendor": "MB connect line",
"versions": [
{
"lessThanOrEqual": "5.1.11",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "mbSPIDER",
"vendor": "MB connect line",
"versions": [
{
"lessThanOrEqual": "2.6.5",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "mbCONNECT24",
"vendor": "MB connect line",
"versions": [
{
"lessThanOrEqual": "2.16.2",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "mymbCONNECT24",
"vendor": "MB connect line",
"versions": [
{
"lessThanOrEqual": "2.16.2",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "REX100",
"vendor": "Helmholz",
"versions": [
{
"lessThanOrEqual": "\u003c= 2.2.13",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "REX200/250",
"vendor": "Helmholz",
"versions": [
{
"lessThanOrEqual": "\u003c= 8.2.0",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "myREX24 V2",
"vendor": "Helmholz",
"versions": [
{
"lessThanOrEqual": "\u003c= 2.16.2",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "myREX24.virtual",
"vendor": "Helmholz",
"versions": [
{
"lessThanOrEqual": "\u003c= 2.16.2",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "REX300",
"vendor": "Helmholz",
"versions": [
{
"lessThanOrEqual": "\u003c= 5.1.11",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Moritz Abrell"
},
{
"lang": "en",
"type": "reporter",
"user": "00000000-0000-4000-9000-000000000000",
"value": "SySS GmbH"
}
],
"datePublic": "2024-10-15T08:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "An unauthenticated local attacker can decrypt the devices config file and therefore compromise the device due to a weak implementation of the encryption used.\u003cbr\u003e"
}
],
"value": "An unauthenticated local attacker can decrypt the devices config file and therefore compromise the device due to a weak implementation of the encryption used."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 8.4,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-261",
"description": "CWE-261: Weak Encoding for Password",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-10-15T10:27:52.208Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2024-056"
},
{
"url": "https://cert.vde.com/en/advisories/VDE-2024-066"
},
{
"url": "https://cert.vde.com/en/advisories/VDE-2024-068"
},
{
"url": "https://cert.vde.com/en/advisories/VDE-2024-069"
}
],
"source": {
"advisory": "VDE-2024-056, VDE-2024-066, VDE-2024-068, VDE-2024-069",
"defect": [
"CERT@VDE#641679",
"CERT@VDE#641695",
"CERT@VDE#641692",
"CERT@VDE#641696"
],
"discovery": "UNKNOWN"
},
"title": "MB connect line/Helmholz: Weak encryption of configuration file",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2024-45273",
"datePublished": "2024-10-15T10:27:52.208Z",
"dateReserved": "2024-08-26T09:19:01.266Z",
"dateUpdated": "2024-10-16T17:47:04.737Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-45271 (GCVE-0-2024-45271)
Vulnerability from cvelistv5 – Published: 2024-10-15 10:27 – Updated: 2025-08-26 14:14
VLAI
Title
MB connect line/Helmholz: Remote code execution due to improper input validation
Summary
An unauthenticated local attacker can gain admin privileges by deploying a config file due to improper input validation.
Severity
8.4 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-94 - Improper Control of Generation of Code ('Code Injection')
Assigner
References
Impacted products
4 products
| Vendor | Product | Version | |
|---|---|---|---|
| MB connect line | mbNET.mini |
Affected:
0.0.0 , ≤ 2.2.13
(semver)
|
|
| Helmholz | REX100 |
Affected:
0.0.0 , ≤ 2.2.13
(semver)
|
|
| mb_connect_line | mbnet.mini |
Affected:
0 , ≤ 2.2.13
(semver)
cpe:2.3:a:mb_connect_line:mbnet.mini:*:*:*:*:*:*:*:* |
|
| rex100 | helmholz |
Affected:
0 , ≤ 2.2.13
(semver)
cpe:2.3:a:rex100:helmholz:*:*:*:*:*:*:*:* |
Date Public
2024-10-15 08:00
Credits
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:mb_connect_line:mbnet.mini:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "mbnet.mini",
"vendor": "mb_connect_line",
"versions": [
{
"lessThanOrEqual": "2.2.13",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"cpes": [
"cpe:2.3:a:rex100:helmholz:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "helmholz",
"vendor": "rex100",
"versions": [
{
"lessThanOrEqual": "2.2.13",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-45271",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-15T13:12:42.565246Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-08-26T14:14:12.044Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-10-16T17:49:30.446Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "https://www.syss.de/fileadmin/dokumente/Publikationen/Advisories/SYSS-2024-059.txt"
}
],
"title": "CVE Program Container",
"x_generator": {
"engine": "ADPogram 0.0.1"
}
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "mbNET.mini",
"vendor": "MB connect line",
"versions": [
{
"lessThanOrEqual": "2.2.13",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "REX100",
"vendor": "Helmholz",
"versions": [
{
"lessThanOrEqual": "2.2.13",
"status": "affected",
"version": "0.0.0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Moritz Abrell"
},
{
"lang": "en",
"type": "reporter",
"user": "00000000-0000-4000-9000-000000000000",
"value": "SySS GmbH"
}
],
"datePublic": "2024-10-15T08:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "An unauthenticated local attacker can gain admin privileges by deploying a config file due to improper input validation.\u003cbr\u003e"
}
],
"value": "An unauthenticated local attacker can gain admin privileges by deploying a config file due to improper input validation."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 8.4,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-94",
"description": "CWE-94 Improper Control of Generation of Code (\u0027Code Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-08-22T06:55:23.671Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"url": "https://cert.vde.com/en/advisories/VDE-2024-056"
},
{
"url": "https://cert.vde.com/en/advisories/VDE-2024-066"
}
],
"source": {
"advisory": "VDE-2024-056, VDE-2024-066",
"defect": [
"CERT@VDE#641679",
"CERT@VDE#641692"
],
"discovery": "UNKNOWN"
},
"title": "MB connect line/Helmholz: Remote code execution due to improper input validation",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2024-45271",
"datePublished": "2024-10-15T10:27:06.004Z",
"dateReserved": "2024-08-26T09:19:01.266Z",
"dateUpdated": "2025-08-26T14:14:12.044Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}