    Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25. plural NETGEAR Devices contain vulnerabilities in insufficient protection of credentials.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. NETGEAR RBK752, etc. are all home WiFi systems of NETGEAR.

    There are security vulnerabilities in many NETGEAR products. Attackers can use this vulnerability to obtain management credentials

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202006-0588",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "rbk752",
            "scope": "lt",
            "trust": 1.6,
            "vendor": "netgear",
            "version": "3.2.15.25"
          },
          {
            "model": "rbr750",
            "scope": "lt",
            "trust": 1.6,
            "vendor": "netgear",
            "version": "3.2.15.25"
          },
          {
            "model": "rbs750",
            "scope": "lt",
            "trust": 1.6,
            "vendor": "netgear",
            "version": "3.2.15.25"
          },
          {
            "model": "rbk753",
            "scope": "lt",
            "trust": 1.6,
            "vendor": "netgear",
            "version": "3.2.15.25"
          },
          {
            "model": "rbk753s",
            "scope": "lt",
            "trust": 1.6,
            "vendor": "netgear",
            "version": "3.2.15.25"
          },
          {
            "model": "rbk842",
            "scope": "lt",
            "trust": 1.6,
            "vendor": "netgear",
            "version": "3.2.15.25"
          },
          {
            "model": "rbr840",
            "scope": "lt",
            "trust": 1.6,
            "vendor": "netgear",
            "version": "3.2.15.25"
          },
          {
            "model": "rbs840",
            "scope": "lt",
            "trust": 1.6,
            "vendor": "netgear",
            "version": "3.2.15.25"
          },
          {
            "model": "rbk852",
            "scope": "lt",
            "trust": 1.6,
            "vendor": "netgear",
            "version": "3.2.15.25"
          },
          {
            "model": "rbk853",
            "scope": "lt",
            "trust": 1.6,
            "vendor": "netgear",
            "version": "3.2.15.25"
          },
          {
            "model": "rbr850",
            "scope": "lt",
            "trust": 1.6,
            "vendor": "netgear",
            "version": "3.2.15.25"
          },
          {
            "model": "rbs850",
            "scope": "lt",
            "trust": 1.6,
            "vendor": "netgear",
            "version": "3.2.15.25"
          },
          {
            "model": "rbk752",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "netgear",
            "version": "3.2.15.25"
          },
          {
            "model": "rbk753",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "netgear",
            "version": "3.2.15.25"
          },
          {
            "model": "rbk753s",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "netgear",
            "version": "3.2.15.25"
          },
          {
            "model": "rbk842",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "netgear",
            "version": "3.2.15.25"
          },
          {
            "model": "rbk852",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "netgear",
            "version": "3.2.15.25"
          },
          {
            "model": "rbk853",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "netgear",
            "version": "3.2.15.25"
          },
          {
            "model": "rbr750",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "netgear",
            "version": "3.2.15.25"
          },
          {
            "model": "rbr840",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "netgear",
            "version": "3.2.15.25"
          },
          {
            "model": "rbr850",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "netgear",
            "version": "3.2.15.25"
          },
          {
            "model": "rbs750",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "netgear",
            "version": "3.2.15.25"
          },
          {
            "model": "rbs840",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "netgear",
            "version": "3.2.15.25"
          },
          {
            "model": "rbs850",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "netgear",
            "version": "3.2.15.25"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-44775"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-006742"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-14430"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "cpe_match": [
                  {
                    "cpe22Uri": "cpe:/o:netgear:rbk752_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:netgear:rbk753_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:netgear:rbk753s_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:netgear:rbk842_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:netgear:rbk852_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:netgear:rbk853_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:netgear:rbr750_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:netgear:rbr840_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:netgear:rbr850_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:netgear:rbs750_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:netgear:rbs840_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:netgear:rbs850_firmware",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-006742"
          }
        ]
      },
      "cve": "CVE-2020-14430",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "ADJACENT_NETWORK",
                "authentication": "NONE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "NONE",
                "baseScore": 3.3,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 6.5,
                "id": "CVE-2020-14430",
                "impactScore": 2.9,
                "integrityImpact": "NONE",
                "severity": "LOW",
                "trust": 1.0,
                "vectorString": "AV:A/AC:L/Au:N/C:P/I:N/A:N",
                "version": "2.0"
              },
              {
                "acInsufInfo": null,
                "accessComplexity": "Low",
                "accessVector": "Adjacent Network",
                "authentication": "None",
                "author": "NVD",
                "availabilityImpact": "None",
                "baseScore": 3.3,
                "confidentialityImpact": "Partial",
                "exploitabilityScore": null,
                "id": "JVNDB-2020-006742",
                "impactScore": null,
                "integrityImpact": "None",
                "obtainAllPrivilege": null,
                "obtainOtherPrivilege": null,
                "obtainUserPrivilege": null,
                "severity": "Low",
                "trust": 0.8,
                "userInteractionRequired": null,
                "vectorString": "AV:A/AC:L/Au:N/C:P/I:N/A:N",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "ADJACENT_NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "NONE",
                "baseScore": 3.3,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 6.5,
                "id": "CNVD-2021-44775",
                "impactScore": 2.9,
                "integrityImpact": "NONE",
                "severity": "LOW",
                "trust": 0.6,
                "vectorString": "AV:A/AC:L/Au:N/C:P/I:N/A:N",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.8,
                "id": "CVE-2020-14430",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT",
                "author": "cve@mitre.org",
                "availabilityImpact": "LOW",
                "baseScore": 9.6,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.8,
                "id": "CVE-2020-14430",
                "impactScore": 6.0,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:L",
                "version": "3.0"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Adjacent Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 8.8,
                "baseSeverity": "High",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "JVNDB-2020-006742",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2020-14430",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "cve@mitre.org",
                "id": "CVE-2020-14430",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "NVD",
                "id": "JVNDB-2020-006742",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2021-44775",
                "trust": 0.6,
                "value": "LOW"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202006-1244",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-44775"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-006742"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202006-1244"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-14430"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-14430"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25. plural NETGEAR Devices contain vulnerabilities in insufficient protection of credentials.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. NETGEAR RBK752, etc. are all home WiFi systems of NETGEAR. \n\r\n\r\nThere are security vulnerabilities in many NETGEAR products. Attackers can use this vulnerability to obtain management credentials",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2020-14430"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-006742"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2021-44775"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2020-14430",
            "trust": 3.0
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-006742",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2021-44775",
            "trust": 0.6
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202006-1244",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-44775"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-006742"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202006-1244"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-14430"
          }
        ]
      },
      "id": "VAR-202006-0588",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-44775"
          }
        ],
        "trust": 1.0097272085714286
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-44775"
          }
        ]
      },
      "last_update_date": "2024-11-23T23:11:24.901000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Security Advisory for Admin Credential Disclosure on Some WiFi Systems, PSV-2020-0051",
            "trust": 0.8,
            "url": "https://kb.netgear.com/000061939/Security-Advisory-for-Admin-Credential-Disclosure-on-Some-WiFi-Systems-PSV-2020-0051"
          },
          {
            "title": "Patch for Information Disclosure Vulnerabilities in Multiple NETGEAR Products (CNVD-2021-44775)",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/275111"
          },
          {
            "title": "Multiple NETGEAR Product security vulnerabilities",
            "trust": 0.6,
            "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=121992"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-44775"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-006742"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202006-1244"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "NVD-CWE-noinfo",
            "trust": 1.0
          },
          {
            "problemtype": "CWE-522",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-006742"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-14430"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.0,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2020-14430"
          },
          {
            "trust": 1.6,
            "url": "https://kb.netgear.com/000061939/security-advisory-for-admin-credential-disclosure-on-some-wifi-systems-psv-2020-0051"
          },
          {
            "trust": 0.8,
            "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-14430"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-44775"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-006742"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202006-1244"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-14430"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-44775"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-006742"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202006-1244"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-14430"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2020-06-24T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2021-44775"
          },
          {
            "date": "2020-07-16T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2020-006742"
          },
          {
            "date": "2020-06-18T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202006-1244"
          },
          {
            "date": "2020-06-18T17:15:12.170000",
            "db": "NVD",
            "id": "CVE-2020-14430"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2021-07-04T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2021-44775"
          },
          {
            "date": "2020-07-16T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2020-006742"
          },
          {
            "date": "2020-06-22T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202006-1244"
          },
          {
            "date": "2024-11-21T05:03:15.150000",
            "db": "NVD",
            "id": "CVE-2020-14430"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote or local",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202006-1244"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "plural  NETGEAR Inadequate protection of credentials on devices",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-006742"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "other",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202006-1244"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202103-1277

    Vulnerability from variot - Updated: 2024-11-23 23:11

    Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects RBW30 before 2.6.2.2, RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, RBK752 before 3.2.17.12, RBK753 before 3.2.17.12, RBK753S before 3.2.17.12, RBK754 before 3.2.17.12, RBR750 before 3.2.17.12, and RBS750 before 3.2.17.12. plural NETGEAR The device contains an out-of-bounds write vulnerability.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. This affects RBW30 prior to 2.6.2.2, RBK852 prior to 3.2.17.12, RBK853 prior to 3.2.17.12, RBK854 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, RBS850 prior to 3.2.17.12, RBK752 prior to 3.2.17.12, RBK753 prior to 3.2.17.12, RBK753S prior to 3.2.17.12, RBK754 prior to 3.2.17.12, RBR750 prior to 3.2.17.12, and RBS750 prior to 3.2.17.12

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202103-1277",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "rbr750",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.17.12"
          },
          {
            "model": "rbk752",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.17.12"
          },
          {
            "model": "rbs850",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.17.12"
          },
          {
            "model": "rbr850",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.17.12"
          },
          {
            "model": "rbk852",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.17.12"
          },
          {
            "model": "rbk753",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.17.12"
          },
          {
            "model": "rbs750",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.17.12"
          },
          {
            "model": "rbk754",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.17.12"
          },
          {
            "model": "rbw30",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "2.6.2.2"
          },
          {
            "model": "rbk853",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.17.12"
          },
          {
            "model": "rbk753s",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.17.12"
          },
          {
            "model": "rbk854",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.17.12"
          },
          {
            "model": "rbk852",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rbk753s",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rbk853",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rbw30",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rbk854",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rbr850",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rbk752",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rbk753",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rbs850",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rbk754",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-004580"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-29074"
          }
        ]
      },
      "cve": "CVE-2021-29074",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "ADJACENT_NETWORK",
                "authentication": "SINGLE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "PARTIAL",
                "baseScore": 5.2,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 5.1,
                "id": "CVE-2021-29074",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 1.9,
                "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 8.4,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 1.7,
                "id": "CVE-2021-29074",
                "impactScore": 6.0,
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "trust": 2.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Adjacent Network",
                "author": "OTHER",
                "availabilityImpact": "High",
                "baseScore": 8.4,
                "baseSeverity": "High",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "JVNDB-2021-004580",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "High",
                "scope": "Changed",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2021-29074",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "cve@mitre.org",
                "id": "CVE-2021-29074",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "NVD",
                "id": "CVE-2021-29074",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202103-1350",
                "trust": 0.6,
                "value": "HIGH"
              },
              {
                "author": "VULMON",
                "id": "CVE-2021-29074",
                "trust": 0.1,
                "value": "MEDIUM"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "VULMON",
            "id": "CVE-2021-29074"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-004580"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202103-1350"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-29074"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-29074"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects RBW30 before 2.6.2.2, RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, RBS850 before 3.2.17.12, RBK752 before 3.2.17.12, RBK753 before 3.2.17.12, RBK753S before 3.2.17.12, RBK754 before 3.2.17.12, RBR750 before 3.2.17.12, and RBS750 before 3.2.17.12. plural NETGEAR The device contains an out-of-bounds write vulnerability.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. This affects RBW30 prior to 2.6.2.2, RBK852 prior to 3.2.17.12, RBK853 prior to 3.2.17.12, RBK854 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, RBS850 prior to 3.2.17.12, RBK752 prior to 3.2.17.12, RBK753 prior to 3.2.17.12, RBK753S prior to 3.2.17.12, RBK754 prior to 3.2.17.12, RBR750 prior to 3.2.17.12, and RBS750 prior to 3.2.17.12",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2021-29074"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-004580"
          },
          {
            "db": "VULMON",
            "id": "CVE-2021-29074"
          }
        ],
        "trust": 1.71
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2021-29074",
            "trust": 2.5
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-004580",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202103-1350",
            "trust": 0.6
          },
          {
            "db": "VULMON",
            "id": "CVE-2021-29074",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "VULMON",
            "id": "CVE-2021-29074"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-004580"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202103-1350"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-29074"
          }
        ]
      },
      "id": "VAR-202103-1277",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "VARIoT devices database",
            "id": null
          }
        ],
        "trust": 0.303985029
      },
      "last_update_date": "2024-11-23T23:11:06.765000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Security\u00a0Advisory\u00a0for\u00a0Post-Authentication\u00a0Stack\u00a0Overflow\u00a0on\u00a0Some\u00a0WiFi\u00a0Routers,\u00a0PSV-2020-0467",
            "trust": 0.8,
            "url": "https://kb.netgear.com/000063011/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-WiFi-Routers-PSV-2020-0467"
          },
          {
            "title": "NETGEAR Repair measures for buffer errors and vulnerabilities in many products",
            "trust": 0.6,
            "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=145889"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-004580"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202103-1350"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-787",
            "trust": 1.0
          },
          {
            "problemtype": "Out-of-bounds writing (CWE-787) [NVD Evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-004580"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-29074"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.7,
            "url": "https://kb.netgear.com/000063011/security-advisory-for-post-authentication-stack-overflow-on-some-wifi-routers-psv-2020-0467"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2021-29074"
          },
          {
            "trust": 0.1,
            "url": "https://cwe.mitre.org/data/definitions/787.html"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov"
          }
        ],
        "sources": [
          {
            "db": "VULMON",
            "id": "CVE-2021-29074"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-004580"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202103-1350"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-29074"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "VULMON",
            "id": "CVE-2021-29074"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-004580"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202103-1350"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-29074"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2021-03-23T00:00:00",
            "db": "VULMON",
            "id": "CVE-2021-29074"
          },
          {
            "date": "2021-11-25T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2021-004580"
          },
          {
            "date": "2021-03-23T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202103-1350"
          },
          {
            "date": "2021-03-23T07:15:13.797000",
            "db": "NVD",
            "id": "CVE-2021-29074"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2021-03-24T00:00:00",
            "db": "VULMON",
            "id": "CVE-2021-29074"
          },
          {
            "date": "2021-11-25T03:10:00",
            "db": "JVNDB",
            "id": "JVNDB-2021-004580"
          },
          {
            "date": "2021-03-31T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202103-1350"
          },
          {
            "date": "2024-11-21T06:00:39.400000",
            "db": "NVD",
            "id": "CVE-2021-29074"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote or local",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202103-1350"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "plural \u00a0NETGEAR\u00a0 Out-of-bounds write vulnerability in device",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-004580"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "buffer error",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202103-1350"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202112-2215

    Vulnerability from variot - Updated: 2024-11-23 23:11

    Certain NETGEAR devices are affected by authentication bypass. This affects CBR750 before 4.6.3.6, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12. plural NETGEAR There is an unspecified vulnerability in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects CBR750 prior to 4.6.3.6, RBK752 prior to 3.2.17.12, RBR750 prior to 3.2.17.12, RBS750 prior to 3.2.17.12, RBK852 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, and RBS850 prior to 3.2.17.12

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2215",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "rbr750",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.17.12"
          },
          {
            "model": "cbr750",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "4.6.3.6"
          },
          {
            "model": "rbs850",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.17.12"
          },
          {
            "model": "rbs750",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.17.12"
          },
          {
            "model": "rbk852",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.17.12"
          },
          {
            "model": "rbr850",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.17.12"
          },
          {
            "model": "rbk752",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.17.12"
          },
          {
            "model": "rbk752",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rbs850",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rbs750",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rbr750",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "cbr750",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rbk852",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rbr850",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-017144"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45506"
          }
        ]
      },
      "cve": "CVE-2021-45506",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "ADJACENT_NETWORK",
                "authentication": "NONE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "PARTIAL",
                "baseScore": 5.8,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 6.5,
                "id": "CVE-2021-45506",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 1.9,
                "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.8,
                "id": "CVE-2021-45506",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT",
                "author": "cve@mitre.org",
                "availabilityImpact": "HIGH",
                "baseScore": 9.6,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.8,
                "id": "CVE-2021-45506",
                "impactScore": 6.0,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Adjacent Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 8.8,
                "baseSeverity": "High",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "CVE-2021-45506",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2021-45506",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "cve@mitre.org",
                "id": "CVE-2021-45506",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "NVD",
                "id": "CVE-2021-45506",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202112-2324",
                "trust": 0.6,
                "value": "HIGH"
              },
              {
                "author": "VULMON",
                "id": "CVE-2021-45506",
                "trust": 0.1,
                "value": "MEDIUM"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "VULMON",
            "id": "CVE-2021-45506"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-017144"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2324"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45506"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45506"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Certain NETGEAR devices are affected by authentication bypass. This affects CBR750 before 4.6.3.6, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12. plural NETGEAR There is an unspecified vulnerability in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects CBR750 prior to 4.6.3.6, RBK752 prior to 3.2.17.12, RBR750 prior to 3.2.17.12, RBS750 prior to 3.2.17.12, RBK852 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, and RBS850 prior to 3.2.17.12",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2021-45506"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-017144"
          },
          {
            "db": "VULMON",
            "id": "CVE-2021-45506"
          }
        ],
        "trust": 1.71
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2021-45506",
            "trust": 3.3
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-017144",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2324",
            "trust": 0.6
          },
          {
            "db": "VULMON",
            "id": "CVE-2021-45506",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "VULMON",
            "id": "CVE-2021-45506"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-017144"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2324"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45506"
          }
        ]
      },
      "id": "VAR-202112-2215",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "VARIoT devices database",
            "id": null
          }
        ],
        "trust": 0.14124016
      },
      "last_update_date": "2024-11-23T23:11:03.149000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Security\u00a0Advisory\u00a0for\u00a0Authentication\u00a0Bypass\u00a0on\u00a0Some\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0483",
            "trust": 0.8,
            "url": "https://kb.netgear.com/000064130/Security-Advisory-for-Authentication-Bypass-on-Some-WiFi-Systems-PSV-2020-0483"
          },
          {
            "title": "Netgear RBR750  and NETGEAR Security vulnerabilities",
            "trust": 0.6,
            "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=176058"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-017144"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2324"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "NVD-CWE-noinfo",
            "trust": 1.0
          },
          {
            "problemtype": "Lack of information (CWE-noinfo) [NVD evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-017144"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45506"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.7,
            "url": "https://kb.netgear.com/000064130/security-advisory-for-authentication-bypass-on-some-wifi-systems-psv-2020-0483"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45506"
          },
          {
            "trust": 0.1,
            "url": "https://cwe.mitre.org/data/definitions/287.html"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov"
          }
        ],
        "sources": [
          {
            "db": "VULMON",
            "id": "CVE-2021-45506"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-017144"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2324"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45506"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "VULMON",
            "id": "CVE-2021-45506"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-017144"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2324"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45506"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2021-12-26T00:00:00",
            "db": "VULMON",
            "id": "CVE-2021-45506"
          },
          {
            "date": "2023-01-05T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2021-017144"
          },
          {
            "date": "2021-12-26T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202112-2324"
          },
          {
            "date": "2021-12-26T01:15:13.183000",
            "db": "NVD",
            "id": "CVE-2021-45506"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2022-01-05T00:00:00",
            "db": "VULMON",
            "id": "CVE-2021-45506"
          },
          {
            "date": "2023-01-05T02:24:00",
            "db": "JVNDB",
            "id": "JVNDB-2021-017144"
          },
          {
            "date": "2022-07-14T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202112-2324"
          },
          {
            "date": "2024-11-21T06:32:22.267000",
            "db": "NVD",
            "id": "CVE-2021-45506"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote or local",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2324"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "plural \u00a0NETGEAR\u00a0 Vulnerabilities in devices",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-017144"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "authorization issue",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2324"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202112-2278

    Vulnerability from variot - Updated: 2024-11-23 23:11

    Certain NETGEAR devices are affected by stored XSS. This affects CBR40 before 2.5.0.10, EAX80 before 1.0.1.62, EX7500 before 1.0.0.72, R7900 before 1.0.4.38, R8000 before 1.0.4.68, RAX200 before 1.0.4.120, RBS40V before 2.6.1.4, RBW30 before 2.6.1.4, MR60 before 1.0.6.110, RAX20 before 1.0.2.82, RAX45 before 1.0.2.72, RAX80 before 1.0.4.120, MS60 before 1.0.6.110, RAX15 before 1.0.2.82, RAX50 before 1.0.2.72, RAX75 before 1.0.4.120, RBR750 before 3.2.16.6, RBR850 before 3.2.16.6, RBS750 before 3.2.16.6, RBS850 before 3.2.16.6, RBK752 before 3.2.16.6, and RBK852 before 3.2.16.6. plural NETGEAR A cross-site scripting vulnerability exists in the device.Information may be obtained and information may be tampered with. This affects CBR40 prior to 2.5.0.10, EAX80 prior to 1.0.1.62, EX7500 prior to 1.0.0.72, R7900 prior to 1.0.4.38, R8000 prior to 1.0.4.68, RAX200 prior to 1.0.4.120, RBS40V prior to 2.6.1.4, RBW30 prior to 2.6.1.4, MR60 prior to 1.0.6.110, RAX20 prior to 1.0.2.82, RAX45 prior to 1.0.2.72, RAX80 prior to 1.0.4.120, MS60 prior to 1.0.6.110, RAX15 prior to 1.0.2.82, RAX50 prior to 1.0.2.72, RAX75 prior to 1.0.4.120, RBR750 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBS850 prior to 3.2.16.6, RBK752 prior to 3.2.16.6, and RBK852 prior to 3.2.16.6

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2278",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "rbs40v",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "2.6.1.4"
          },
          {
            "model": "rax45",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.2.72"
          },
          {
            "model": "rbk752",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.16.6"
          },
          {
            "model": "r7900",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.4.38"
          },
          {
            "model": "r8000",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.4.68"
          },
          {
            "model": "rax20",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.2.82"
          },
          {
            "model": "rbr850",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.16.6"
          },
          {
            "model": "mr60",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.6.110"
          },
          {
            "model": "rbk852",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.16.6"
          },
          {
            "model": "rax200",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.4.120"
          },
          {
            "model": "ms60",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.6.110"
          },
          {
            "model": "ex7500",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.0.72"
          },
          {
            "model": "rbw30",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "2.6.1.4"
          },
          {
            "model": "rax15",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.2.82"
          },
          {
            "model": "rax80",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.4.120"
          },
          {
            "model": "rbs750",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.16.6"
          },
          {
            "model": "eax80",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.1.62"
          },
          {
            "model": "rax75",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.4.120"
          },
          {
            "model": "rbr750",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.16.6"
          },
          {
            "model": "rax50",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.2.72"
          },
          {
            "model": "cbr40",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "2.5.0.10"
          },
          {
            "model": "rbs850",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.16.6"
          },
          {
            "model": "rax20",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "ms60",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rax15",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rax80",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rax45",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rbr750",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rax200",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rax50",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "mr60",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rax75",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-017027"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45671"
          }
        ]
      },
      "cve": "CVE-2021-45671",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "MEDIUM",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "NONE",
                "baseScore": 3.5,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 6.8,
                "id": "CVE-2021-45671",
                "impactScore": 2.9,
                "integrityImpact": "PARTIAL",
                "severity": "LOW",
                "trust": 1.9,
                "vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "NONE",
                "baseScore": 4.8,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "exploitabilityScore": 1.7,
                "id": "CVE-2021-45671",
                "impactScore": 2.7,
                "integrityImpact": "LOW",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "trust": 1.0,
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
                "version": "3.1"
              },
              {
                "attackComplexity": "HIGH",
                "attackVector": "ADJACENT",
                "author": "cve@mitre.org",
                "availabilityImpact": "LOW",
                "baseScore": 6.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "exploitabilityScore": 0.7,
                "id": "CVE-2021-45671",
                "impactScore": 5.3,
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "trust": 1.0,
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:A/AC:H/PR:H/UI:R/S:C/C:L/I:H/A:L",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "None",
                "baseScore": 4.8,
                "baseSeverity": "Medium",
                "confidentialityImpact": "Low",
                "exploitabilityScore": null,
                "id": "CVE-2021-45671",
                "impactScore": null,
                "integrityImpact": "Low",
                "privilegesRequired": "High",
                "scope": "Changed",
                "trust": 0.8,
                "userInteraction": "Required",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2021-45671",
                "trust": 1.0,
                "value": "MEDIUM"
              },
              {
                "author": "cve@mitre.org",
                "id": "CVE-2021-45671",
                "trust": 1.0,
                "value": "MEDIUM"
              },
              {
                "author": "NVD",
                "id": "CVE-2021-45671",
                "trust": 0.8,
                "value": "Medium"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202112-2465",
                "trust": 0.6,
                "value": "MEDIUM"
              },
              {
                "author": "VULMON",
                "id": "CVE-2021-45671",
                "trust": 0.1,
                "value": "LOW"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "VULMON",
            "id": "CVE-2021-45671"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-017027"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2465"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45671"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45671"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Certain NETGEAR devices are affected by stored XSS. This affects CBR40 before 2.5.0.10, EAX80 before 1.0.1.62, EX7500 before 1.0.0.72, R7900 before 1.0.4.38, R8000 before 1.0.4.68, RAX200 before 1.0.4.120, RBS40V before 2.6.1.4, RBW30 before 2.6.1.4, MR60 before 1.0.6.110, RAX20 before 1.0.2.82, RAX45 before 1.0.2.72, RAX80 before 1.0.4.120, MS60 before 1.0.6.110, RAX15 before 1.0.2.82, RAX50 before 1.0.2.72, RAX75 before 1.0.4.120, RBR750 before 3.2.16.6, RBR850 before 3.2.16.6, RBS750 before 3.2.16.6, RBS850 before 3.2.16.6, RBK752 before 3.2.16.6, and RBK852 before 3.2.16.6. plural NETGEAR A cross-site scripting vulnerability exists in the device.Information may be obtained and information may be tampered with. This affects CBR40 prior to 2.5.0.10, EAX80 prior to 1.0.1.62, EX7500 prior to 1.0.0.72, R7900 prior to 1.0.4.38, R8000 prior to 1.0.4.68, RAX200 prior to 1.0.4.120, RBS40V prior to 2.6.1.4, RBW30 prior to 2.6.1.4, MR60 prior to 1.0.6.110, RAX20 prior to 1.0.2.82, RAX45 prior to 1.0.2.72, RAX80 prior to 1.0.4.120, MS60 prior to 1.0.6.110, RAX15 prior to 1.0.2.82, RAX50 prior to 1.0.2.72, RAX75 prior to 1.0.4.120, RBR750 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBS850 prior to 3.2.16.6, RBK752 prior to 3.2.16.6, and RBK852 prior to 3.2.16.6",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2021-45671"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-017027"
          },
          {
            "db": "VULMON",
            "id": "CVE-2021-45671"
          }
        ],
        "trust": 1.71
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2021-45671",
            "trust": 3.3
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-017027",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2465",
            "trust": 0.6
          },
          {
            "db": "VULMON",
            "id": "CVE-2021-45671",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "VULMON",
            "id": "CVE-2021-45671"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-017027"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2465"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45671"
          }
        ]
      },
      "id": "VAR-202112-2278",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "VARIoT devices database",
            "id": null
          }
        ],
        "trust": 0.25279196375
      },
      "last_update_date": "2024-11-23T23:11:03.123000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Security\u00a0Advisory\u00a0for\u00a0Stored\u00a0Cross\u00a0Site\u00a0Scripting\u00a0on\u00a0Some\u00a0Routers,\u00a0Extenders,\u00a0and\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0261",
            "trust": 0.8,
            "url": "https://kb.netgear.com/000064482/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2020-0261"
          },
          {
            "title": "Netgear RBR750  and NETGEAR Security vulnerabilities",
            "trust": 0.6,
            "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=175884"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-017027"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2465"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-79",
            "trust": 1.0
          },
          {
            "problemtype": "Cross-site scripting (CWE-79) [NVD evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-017027"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45671"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.7,
            "url": "https://kb.netgear.com/000064482/security-advisory-for-stored-cross-site-scripting-on-some-routers-extenders-and-wifi-systems-psv-2020-0261"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45671"
          },
          {
            "trust": 0.1,
            "url": "https://cwe.mitre.org/data/definitions/79.html"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov"
          }
        ],
        "sources": [
          {
            "db": "VULMON",
            "id": "CVE-2021-45671"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-017027"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2465"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45671"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "VULMON",
            "id": "CVE-2021-45671"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-017027"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2465"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45671"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2021-12-26T00:00:00",
            "db": "VULMON",
            "id": "CVE-2021-45671"
          },
          {
            "date": "2022-12-28T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2021-017027"
          },
          {
            "date": "2021-12-26T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202112-2465"
          },
          {
            "date": "2021-12-26T01:15:21.057000",
            "db": "NVD",
            "id": "CVE-2021-45671"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2022-01-05T00:00:00",
            "db": "VULMON",
            "id": "CVE-2021-45671"
          },
          {
            "date": "2022-12-28T00:05:00",
            "db": "JVNDB",
            "id": "JVNDB-2021-017027"
          },
          {
            "date": "2022-01-06T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202112-2465"
          },
          {
            "date": "2024-11-21T06:32:50.550000",
            "db": "NVD",
            "id": "CVE-2021-45671"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2465"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "plural \u00a0NETGEAR\u00a0 Cross-site scripting vulnerabilities in devices",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-017027"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "XSS",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2465"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202112-2320

    Vulnerability from variot - Updated: 2024-11-23 23:11

    Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR750 before 4.6.3.6, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects CBR750 prior to 4.6.3.6, RBK752 prior to 3.2.17.12, RBR750 prior to 3.2.17.12, RBS750 prior to 3.2.17.12, RBK852 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, and RBS850 prior to 3.2.17.12

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2320",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "rbr750",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.17.12"
          },
          {
            "model": "cbr750",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "4.6.3.6"
          },
          {
            "model": "rbs850",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.17.12"
          },
          {
            "model": "rbs750",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.17.12"
          },
          {
            "model": "rbk852",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.17.12"
          },
          {
            "model": "rbr850",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.17.12"
          },
          {
            "model": "rbk752",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.17.12"
          },
          {
            "model": "rbr850",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rbs850",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rbk852",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "cbr750",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rbk752",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rbr750",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rbs750",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-017045"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45629"
          }
        ]
      },
      "cve": "CVE-2021-45629",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "ADJACENT_NETWORK",
                "authentication": "NONE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "PARTIAL",
                "baseScore": 5.8,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 6.5,
                "id": "CVE-2021-45629",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 1.9,
                "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.8,
                "id": "CVE-2021-45629",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT",
                "author": "cve@mitre.org",
                "availabilityImpact": "HIGH",
                "baseScore": 9.6,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.8,
                "id": "CVE-2021-45629",
                "impactScore": 6.0,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Adjacent Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 8.8,
                "baseSeverity": "High",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "CVE-2021-45629",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2021-45629",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "cve@mitre.org",
                "id": "CVE-2021-45629",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "NVD",
                "id": "CVE-2021-45629",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202112-2425",
                "trust": 0.6,
                "value": "HIGH"
              },
              {
                "author": "VULMON",
                "id": "CVE-2021-45629",
                "trust": 0.1,
                "value": "MEDIUM"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "VULMON",
            "id": "CVE-2021-45629"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-017045"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2425"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45629"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45629"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR750 before 4.6.3.6, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects CBR750 prior to 4.6.3.6, RBK752 prior to 3.2.17.12, RBR750 prior to 3.2.17.12, RBS750 prior to 3.2.17.12, RBK852 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, and RBS850 prior to 3.2.17.12",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2021-45629"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-017045"
          },
          {
            "db": "VULMON",
            "id": "CVE-2021-45629"
          }
        ],
        "trust": 1.71
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2021-45629",
            "trust": 3.3
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-017045",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2425",
            "trust": 0.6
          },
          {
            "db": "VULMON",
            "id": "CVE-2021-45629",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "VULMON",
            "id": "CVE-2021-45629"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-017045"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2425"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45629"
          }
        ]
      },
      "id": "VAR-202112-2320",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "VARIoT devices database",
            "id": null
          }
        ],
        "trust": 0.14124016
      },
      "last_update_date": "2024-11-23T23:11:03.073000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Security\u00a0Advisory\u00a0for\u00a0Pre-Authentication\u00a0Command\u00a0Injection\u00a0on\u00a0Some\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0488",
            "trust": 0.8,
            "url": "https://kb.netgear.com/000064132/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0488"
          },
          {
            "title": "NETGEAR Repair measures for device security vulnerabilities",
            "trust": 0.6,
            "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=176404"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-017045"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2425"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-77",
            "trust": 1.0
          },
          {
            "problemtype": "Command injection (CWE-77) [NVD evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-017045"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45629"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.7,
            "url": "https://kb.netgear.com/000064132/security-advisory-for-pre-authentication-command-injection-on-some-wifi-systems-psv-2020-0488"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45629"
          },
          {
            "trust": 0.1,
            "url": "https://cwe.mitre.org/data/definitions/77.html"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov"
          }
        ],
        "sources": [
          {
            "db": "VULMON",
            "id": "CVE-2021-45629"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-017045"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2425"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45629"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "VULMON",
            "id": "CVE-2021-45629"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-017045"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2425"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45629"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2021-12-26T00:00:00",
            "db": "VULMON",
            "id": "CVE-2021-45629"
          },
          {
            "date": "2022-12-28T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2021-017045"
          },
          {
            "date": "2021-12-26T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202112-2425"
          },
          {
            "date": "2021-12-26T01:15:19.143000",
            "db": "NVD",
            "id": "CVE-2021-45629"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2022-01-05T00:00:00",
            "db": "VULMON",
            "id": "CVE-2021-45629"
          },
          {
            "date": "2022-12-28T03:02:00",
            "db": "JVNDB",
            "id": "JVNDB-2021-017045"
          },
          {
            "date": "2022-01-06T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202112-2425"
          },
          {
            "date": "2024-11-21T06:32:43.320000",
            "db": "NVD",
            "id": "CVE-2021-45629"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote or local",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2425"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "plural \u00a0NETGEAR\u00a0 Command injection vulnerability in device",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-017045"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "command injection",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2425"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202112-2362

    Vulnerability from variot - Updated: 2024-11-23 23:11

    Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects RBK752 prior to 3.2.16.6, RBR750 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBK852 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, and RBS850 prior to 3.2.16.6

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2362",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "rbr850",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.16.6"
          },
          {
            "model": "rbk752",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.16.6"
          },
          {
            "model": "rbr750",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.16.6"
          },
          {
            "model": "rbk852",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.16.6"
          },
          {
            "model": "rbs850",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.16.6"
          },
          {
            "model": "rbs750",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.16.6"
          },
          {
            "model": "rbr750",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rbk752",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rbr850",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rbs750",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rbk852",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rbs850",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-016909"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45587"
          }
        ]
      },
      "cve": "CVE-2021-45587",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "ADJACENT_NETWORK",
                "authentication": "SINGLE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "PARTIAL",
                "baseScore": 5.2,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 5.1,
                "id": "CVE-2021-45587",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 1.9,
                "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 6.8,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 0.9,
                "id": "CVE-2021-45587",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT",
                "author": "cve@mitre.org",
                "availabilityImpact": "HIGH",
                "baseScore": 8.4,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 1.7,
                "id": "CVE-2021-45587",
                "impactScore": 6.0,
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Adjacent Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 6.8,
                "baseSeverity": "Medium",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "CVE-2021-45587",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "High",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2021-45587",
                "trust": 1.0,
                "value": "MEDIUM"
              },
              {
                "author": "cve@mitre.org",
                "id": "CVE-2021-45587",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "NVD",
                "id": "CVE-2021-45587",
                "trust": 0.8,
                "value": "Medium"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202112-2386",
                "trust": 0.6,
                "value": "MEDIUM"
              },
              {
                "author": "VULMON",
                "id": "CVE-2021-45587",
                "trust": 0.1,
                "value": "MEDIUM"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "VULMON",
            "id": "CVE-2021-45587"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-016909"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2386"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45587"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45587"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects RBK752 prior to 3.2.16.6, RBR750 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBK852 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, and RBS850 prior to 3.2.16.6",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2021-45587"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-016909"
          },
          {
            "db": "VULMON",
            "id": "CVE-2021-45587"
          }
        ],
        "trust": 1.71
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2021-45587",
            "trust": 3.3
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-016909",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2386",
            "trust": 0.6
          },
          {
            "db": "VULMON",
            "id": "CVE-2021-45587",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "VULMON",
            "id": "CVE-2021-45587"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-016909"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2386"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45587"
          }
        ]
      },
      "id": "VAR-202112-2362",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "VARIoT devices database",
            "id": null
          }
        ],
        "trust": 0.14124016
      },
      "last_update_date": "2024-11-23T23:11:03.022000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Security\u00a0Advisory\u00a0for\u00a0Post-Authentication\u00a0Command\u00a0Injection\u00a0on\u00a0Some\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0095",
            "trust": 0.8,
            "url": "https://kb.netgear.com/000064109/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0095"
          },
          {
            "title": "Netgear NETGEAR Fixes for command injection vulnerabilities",
            "trust": 0.6,
            "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=177102"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-016909"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2386"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-77",
            "trust": 1.0
          },
          {
            "problemtype": "Command injection (CWE-77) [NVD evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-016909"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45587"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.7,
            "url": "https://kb.netgear.com/000064109/security-advisory-for-post-authentication-command-injection-on-some-wifi-systems-psv-2020-0095"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45587"
          },
          {
            "trust": 0.1,
            "url": "https://cwe.mitre.org/data/definitions/77.html"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov"
          }
        ],
        "sources": [
          {
            "db": "VULMON",
            "id": "CVE-2021-45587"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-016909"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2386"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45587"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "VULMON",
            "id": "CVE-2021-45587"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-016909"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2386"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45587"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2021-12-26T00:00:00",
            "db": "VULMON",
            "id": "CVE-2021-45587"
          },
          {
            "date": "2022-12-27T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2021-016909"
          },
          {
            "date": "2021-12-26T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202112-2386"
          },
          {
            "date": "2021-12-26T01:15:17.117000",
            "db": "NVD",
            "id": "CVE-2021-45587"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2022-01-04T00:00:00",
            "db": "VULMON",
            "id": "CVE-2021-45587"
          },
          {
            "date": "2022-12-27T01:41:00",
            "db": "JVNDB",
            "id": "JVNDB-2021-016909"
          },
          {
            "date": "2022-01-05T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202112-2386"
          },
          {
            "date": "2024-11-21T06:32:35.937000",
            "db": "NVD",
            "id": "CVE-2021-45587"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote or local",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2386"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "plural \u00a0NETGEAR\u00a0 Command injection vulnerability in device",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-016909"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "command injection",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2386"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202112-2402

    Vulnerability from variot - Updated: 2024-11-23 23:11

    Certain NETGEAR devices are affected by command injection by an authenticated user. This affects R7850 before 1.0.5.74, R7900P before 1.4.2.84, R7960P before 1.4.2.84, R8000 before 1.0.4.74, R8000P before 1.4.2.84, RAX200 before 1.0.4.120, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK752 before 3.2.17.12, RBK852 before 3.2.17.12, RBR750 before 3.2.17.12, RBR850 before 3.2.17.12, RBS750 before 3.2.17.12, and RBS850 before 3.2.17.12. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects R7850 prior to 1.0.5.74, R7900P prior to 1.4.2.84, R7960P prior to 1.4.2.84, R8000 prior to 1.0.4.74, R8000P prior to 1.4.2.84, RAX200 prior to 1.0.4.120, RAX75 prior to 1.0.4.120, RAX80 prior to 1.0.4.120, RBK752 prior to 3.2.17.12, RBK852 prior to 3.2.17.12, RBR750 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, RBS750 prior to 3.2.17.12, and RBS850 prior to 3.2.17.12

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2402",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "rbr750",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.17.12"
          },
          {
            "model": "rbs850",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.17.12"
          },
          {
            "model": "rbr850",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.17.12"
          },
          {
            "model": "r7960p",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.4.2.84"
          },
          {
            "model": "rax80",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.4.120"
          },
          {
            "model": "rbk852",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.17.12"
          },
          {
            "model": "rax75",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.4.120"
          },
          {
            "model": "r8000p",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.4.2.84"
          },
          {
            "model": "rbk752",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.17.12"
          },
          {
            "model": "r7900p",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.4.2.84"
          },
          {
            "model": "r8000",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.4.74"
          },
          {
            "model": "rbs750",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.17.12"
          },
          {
            "model": "rax200",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.4.120"
          },
          {
            "model": "r7850",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.5.74"
          },
          {
            "model": "r8000p",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rbr850",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rax80",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "r7960p",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "r7900p",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rax75",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rbk852",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "r8000",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rax200",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "r7850",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-017188"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45546"
          }
        ]
      },
      "cve": "CVE-2021-45546",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "PARTIAL",
                "baseScore": 6.5,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 8.0,
                "id": "CVE-2021-45546",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 1.9,
                "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.8,
                "id": "CVE-2021-45546",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT",
                "author": "cve@mitre.org",
                "availabilityImpact": "HIGH",
                "baseScore": 8.4,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 1.7,
                "id": "CVE-2021-45546",
                "impactScore": 6.0,
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 8.8,
                "baseSeverity": "High",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "CVE-2021-45546",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "Low",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2021-45546",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "cve@mitre.org",
                "id": "CVE-2021-45546",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "NVD",
                "id": "CVE-2021-45546",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202112-2361",
                "trust": 0.6,
                "value": "HIGH"
              },
              {
                "author": "VULMON",
                "id": "CVE-2021-45546",
                "trust": 0.1,
                "value": "MEDIUM"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "VULMON",
            "id": "CVE-2021-45546"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-017188"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2361"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45546"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45546"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects R7850 before 1.0.5.74, R7900P before 1.4.2.84, R7960P before 1.4.2.84, R8000 before 1.0.4.74, R8000P before 1.4.2.84, RAX200 before 1.0.4.120, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK752 before 3.2.17.12, RBK852 before 3.2.17.12, RBR750 before 3.2.17.12, RBR850 before 3.2.17.12, RBS750 before 3.2.17.12, and RBS850 before 3.2.17.12. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects R7850 prior to 1.0.5.74, R7900P prior to 1.4.2.84, R7960P prior to 1.4.2.84, R8000 prior to 1.0.4.74, R8000P prior to 1.4.2.84, RAX200 prior to 1.0.4.120, RAX75 prior to 1.0.4.120, RAX80 prior to 1.0.4.120, RBK752 prior to 3.2.17.12, RBK852 prior to 3.2.17.12, RBR750 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, RBS750 prior to 3.2.17.12, and RBS850 prior to 3.2.17.12",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2021-45546"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-017188"
          },
          {
            "db": "VULMON",
            "id": "CVE-2021-45546"
          }
        ],
        "trust": 1.71
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2021-45546",
            "trust": 3.3
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-017188",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2361",
            "trust": 0.6
          },
          {
            "db": "VULMON",
            "id": "CVE-2021-45546",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "VULMON",
            "id": "CVE-2021-45546"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-017188"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2361"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45546"
          }
        ]
      },
      "id": "VAR-202112-2402",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "VARIoT devices database",
            "id": null
          }
        ],
        "trust": 0.2583164825
      },
      "last_update_date": "2024-11-23T23:11:02.998000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Security\u00a0Advisory\u00a0for\u00a0Post-Authentication\u00a0Command\u00a0Injection\u00a0on\u00a0Some\u00a0Routers\u00a0and\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0566",
            "trust": 0.8,
            "url": "https://kb.netgear.com/000064524/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2020-0566"
          },
          {
            "title": "Netgear RBR750  and NETGEAR Security vulnerabilities",
            "trust": 0.6,
            "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=176374"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-017188"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2361"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-77",
            "trust": 1.0
          },
          {
            "problemtype": "Command injection (CWE-77) [NVD evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-017188"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45546"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.7,
            "url": "https://kb.netgear.com/000064524/security-advisory-for-post-authentication-command-injection-on-some-routers-and-wifi-systems-psv-2020-0566"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45546"
          },
          {
            "trust": 0.1,
            "url": "https://cwe.mitre.org/data/definitions/77.html"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov"
          }
        ],
        "sources": [
          {
            "db": "VULMON",
            "id": "CVE-2021-45546"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-017188"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2361"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45546"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "VULMON",
            "id": "CVE-2021-45546"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-017188"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2361"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45546"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2021-12-26T00:00:00",
            "db": "VULMON",
            "id": "CVE-2021-45546"
          },
          {
            "date": "2023-01-06T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2021-017188"
          },
          {
            "date": "2021-12-26T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202112-2361"
          },
          {
            "date": "2021-12-26T01:15:15.177000",
            "db": "NVD",
            "id": "CVE-2021-45546"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2022-01-06T00:00:00",
            "db": "VULMON",
            "id": "CVE-2021-45546"
          },
          {
            "date": "2023-01-06T07:14:00",
            "db": "JVNDB",
            "id": "JVNDB-2021-017188"
          },
          {
            "date": "2022-01-07T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202112-2361"
          },
          {
            "date": "2024-11-21T06:32:28.830000",
            "db": "NVD",
            "id": "CVE-2021-45546"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2361"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "plural \u00a0NETGEAR\u00a0 Command injection vulnerability in device",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-017188"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "command injection",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2361"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202006-0935

    Vulnerability from variot - Updated: 2024-11-23 23:07

    Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25. plural NETGEAR On the device OS A command injection vulnerability exists.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. NETGEAR RBK752, etc. are all home WiFi systems of NETGEAR. Attackers can use this vulnerability to execute arbitrary Shell commands on the system by sending a specially crafted request. This affects RBK752 prior to 3.2.15.25, RBK753 prior to 3.2.15.25, RBK753S prior to 3.2.15.25, RBR750 prior to 3.2.15.25, RBS750 prior to 3.2.15.25, RBK842 prior to 3.2.15.25, RBR840 prior to 3.2.15.25, RBS840 prior to 3.2.15.25, RBK852 prior to 3.2.15.25, RBK853 prior to 3.2.15.25, RBR850 prior to 3.2.15.25, and RBS850 prior to 3.2.15.25

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202006-0935",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "rbk752",
            "scope": "lt",
            "trust": 1.6,
            "vendor": "netgear",
            "version": "3.2.15.25"
          },
          {
            "model": "rbr750",
            "scope": "lt",
            "trust": 1.6,
            "vendor": "netgear",
            "version": "3.2.15.25"
          },
          {
            "model": "rbs750",
            "scope": "lt",
            "trust": 1.6,
            "vendor": "netgear",
            "version": "3.2.15.25"
          },
          {
            "model": "rbk753",
            "scope": "lt",
            "trust": 1.6,
            "vendor": "netgear",
            "version": "3.2.15.25"
          },
          {
            "model": "rbk753s",
            "scope": "lt",
            "trust": 1.6,
            "vendor": "netgear",
            "version": "3.2.15.25"
          },
          {
            "model": "rbk842",
            "scope": "lt",
            "trust": 1.6,
            "vendor": "netgear",
            "version": "3.2.15.25"
          },
          {
            "model": "rbr840",
            "scope": "lt",
            "trust": 1.6,
            "vendor": "netgear",
            "version": "3.2.15.25"
          },
          {
            "model": "rbs840",
            "scope": "lt",
            "trust": 1.6,
            "vendor": "netgear",
            "version": "3.2.15.25"
          },
          {
            "model": "rbk852",
            "scope": "lt",
            "trust": 1.6,
            "vendor": "netgear",
            "version": "3.2.15.25"
          },
          {
            "model": "rbk853",
            "scope": "lt",
            "trust": 1.6,
            "vendor": "netgear",
            "version": "3.2.15.25"
          },
          {
            "model": "rbr850",
            "scope": "lt",
            "trust": 1.6,
            "vendor": "netgear",
            "version": "3.2.15.25"
          },
          {
            "model": "rbs850",
            "scope": "lt",
            "trust": 1.6,
            "vendor": "netgear",
            "version": "3.2.15.25"
          },
          {
            "model": "rbk752",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "netgear",
            "version": "3.2.15.25"
          },
          {
            "model": "rbk753",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "netgear",
            "version": "3.2.15.25"
          },
          {
            "model": "rbk753s",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "netgear",
            "version": "3.2.15.25"
          },
          {
            "model": "rbk842",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "netgear",
            "version": "3.2.15.25"
          },
          {
            "model": "rbk852",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "netgear",
            "version": "3.2.15.25"
          },
          {
            "model": "rbk853",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "netgear",
            "version": "3.2.15.25"
          },
          {
            "model": "rbr750",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "netgear",
            "version": "3.2.15.25"
          },
          {
            "model": "rbr840",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "netgear",
            "version": "3.2.15.25"
          },
          {
            "model": "rbs750",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "netgear",
            "version": "3.2.15.25"
          },
          {
            "model": "rbs840",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "netgear",
            "version": "3.2.15.25"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-44783"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-006685"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-14438"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "cpe_match": [
                  {
                    "cpe22Uri": "cpe:/o:netgear:rbk752_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:netgear:rbk753_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:netgear:rbk753s_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:netgear:rbk842_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:netgear:rbk852_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:netgear:rbk853_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:netgear:rbr750_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:netgear:rbr840_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:netgear:rbs750_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:netgear:rbs840_firmware",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-006685"
          }
        ]
      },
      "cve": "CVE-2020-14438",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "ADJACENT_NETWORK",
                "authentication": "NONE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "PARTIAL",
                "baseScore": 5.8,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 6.5,
                "id": "CVE-2020-14438",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 1.1,
                "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P",
                "version": "2.0"
              },
              {
                "acInsufInfo": null,
                "accessComplexity": "Low",
                "accessVector": "Adjacent Network",
                "authentication": "None",
                "author": "NVD",
                "availabilityImpact": "Partial",
                "baseScore": 5.8,
                "confidentialityImpact": "Partial",
                "exploitabilityScore": null,
                "id": "JVNDB-2020-006685",
                "impactScore": null,
                "integrityImpact": "Partial",
                "obtainAllPrivilege": null,
                "obtainOtherPrivilege": null,
                "obtainUserPrivilege": null,
                "severity": "Medium",
                "trust": 0.8,
                "userInteractionRequired": null,
                "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P",
                "version": "2.0"
              },
              {
                "accessComplexity": "HIGH",
                "accessVector": "ADJACENT_NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "PARTIAL",
                "baseScore": 4.3,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 3.2,
                "id": "CNVD-2021-44783",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 0.6,
                "vectorString": "AV:A/AC:H/Au:N/C:P/I:P/A:P",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.8,
                "id": "CVE-2020-14438",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT",
                "author": "cve@mitre.org",
                "availabilityImpact": "LOW",
                "baseScore": 9.6,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.8,
                "id": "CVE-2020-14438",
                "impactScore": 6.0,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:L",
                "version": "3.0"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Adjacent Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 8.8,
                "baseSeverity": "High",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "JVNDB-2020-006685",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2020-14438",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "cve@mitre.org",
                "id": "CVE-2020-14438",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "NVD",
                "id": "JVNDB-2020-006685",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2021-44783",
                "trust": 0.6,
                "value": "MEDIUM"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202006-1254",
                "trust": 0.6,
                "value": "HIGH"
              },
              {
                "author": "VULMON",
                "id": "CVE-2020-14438",
                "trust": 0.1,
                "value": "MEDIUM"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-44783"
          },
          {
            "db": "VULMON",
            "id": "CVE-2020-14438"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-006685"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202006-1254"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-14438"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-14438"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25. plural NETGEAR On the device OS A command injection vulnerability exists.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. NETGEAR RBK752, etc. are all home WiFi systems of NETGEAR. Attackers can use this vulnerability to execute arbitrary Shell commands on the system by sending a specially crafted request. This affects RBK752 prior to 3.2.15.25, RBK753 prior to 3.2.15.25, RBK753S prior to 3.2.15.25, RBR750 prior to 3.2.15.25, RBS750 prior to 3.2.15.25, RBK842 prior to 3.2.15.25, RBR840 prior to 3.2.15.25, RBS840 prior to 3.2.15.25, RBK852 prior to 3.2.15.25, RBK853 prior to 3.2.15.25, RBR850 prior to 3.2.15.25, and RBS850 prior to 3.2.15.25",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2020-14438"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-006685"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2021-44783"
          },
          {
            "db": "VULMON",
            "id": "CVE-2020-14438"
          }
        ],
        "trust": 2.25
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2020-14438",
            "trust": 3.1
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-006685",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2021-44783",
            "trust": 0.6
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202006-1254",
            "trust": 0.6
          },
          {
            "db": "VULMON",
            "id": "CVE-2020-14438",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-44783"
          },
          {
            "db": "VULMON",
            "id": "CVE-2020-14438"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-006685"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202006-1254"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-14438"
          }
        ]
      },
      "id": "VAR-202006-0935",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-44783"
          }
        ],
        "trust": 1.0097272085714286
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-44783"
          }
        ]
      },
      "last_update_date": "2024-11-23T23:07:56.401000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Security Advisory for Pre-Authentification Command Injection on Some WiFi Systems, PSV-2020-0063",
            "trust": 0.8,
            "url": "https://kb.netgear.com/000061941/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0063"
          },
          {
            "title": "Patch for Operating system command injection vulnerabilities in multiple NETGEAR products (CNVD-2021-44783)",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/274926"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-44783"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-006685"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-77",
            "trust": 1.0
          },
          {
            "problemtype": "CWE-78",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-006685"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-14438"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.0,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2020-14438"
          },
          {
            "trust": 1.7,
            "url": "https://kb.netgear.com/000061941/security-advisory-for-pre-authentication-command-injection-on-some-wifi-systems-psv-2020-0063"
          },
          {
            "trust": 0.8,
            "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-14438"
          },
          {
            "trust": 0.1,
            "url": "https://cwe.mitre.org/data/definitions/77.html"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-44783"
          },
          {
            "db": "VULMON",
            "id": "CVE-2020-14438"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-006685"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202006-1254"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-14438"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-44783"
          },
          {
            "db": "VULMON",
            "id": "CVE-2020-14438"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-006685"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202006-1254"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-14438"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2020-06-24T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2021-44783"
          },
          {
            "date": "2020-06-18T00:00:00",
            "db": "VULMON",
            "id": "CVE-2020-14438"
          },
          {
            "date": "2020-07-15T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2020-006685"
          },
          {
            "date": "2020-06-18T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202006-1254"
          },
          {
            "date": "2020-06-18T17:15:12.953000",
            "db": "NVD",
            "id": "CVE-2020-14438"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2021-06-24T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2021-44783"
          },
          {
            "date": "2021-07-21T00:00:00",
            "db": "VULMON",
            "id": "CVE-2020-14438"
          },
          {
            "date": "2020-07-15T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2020-006685"
          },
          {
            "date": "2020-07-02T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202006-1254"
          },
          {
            "date": "2024-11-21T05:03:16.597000",
            "db": "NVD",
            "id": "CVE-2020-14438"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote or local",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202006-1254"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "plural  NETGEAR On the device  OS Command injection vulnerabilities",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-006685"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "operating system commend injection",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202006-1254"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202103-1275

    Vulnerability from variot - Updated: 2024-11-23 23:07

    Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. This affects RBK852 prior to 3.2.17.12, RBK853 prior to 3.2.17.12, RBK854 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, and RBS850 prior to 3.2.17.12

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202103-1275",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "rbk853",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.17.12"
          },
          {
            "model": "rbr850",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.17.12"
          },
          {
            "model": "rbs850",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.17.12"
          },
          {
            "model": "rbk852",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.17.12"
          },
          {
            "model": "rbk854",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.17.12"
          },
          {
            "model": "rbk852",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rbk853",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rbk854",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rbr850",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rbs850",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-004578"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-29072"
          }
        ]
      },
      "cve": "CVE-2021-29072",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "ADJACENT_NETWORK",
                "authentication": "SINGLE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "PARTIAL",
                "baseScore": 5.2,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 5.1,
                "id": "CVE-2021-29072",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 1.9,
                "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 8.4,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 1.7,
                "id": "CVE-2021-29072",
                "impactScore": 6.0,
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "trust": 2.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Adjacent Network",
                "author": "OTHER",
                "availabilityImpact": "High",
                "baseScore": 8.4,
                "baseSeverity": "High",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "JVNDB-2021-004578",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "High",
                "scope": "Changed",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2021-29072",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "cve@mitre.org",
                "id": "CVE-2021-29072",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "NVD",
                "id": "CVE-2021-29072",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202103-1354",
                "trust": 0.6,
                "value": "HIGH"
              },
              {
                "author": "VULMON",
                "id": "CVE-2021-29072",
                "trust": 0.1,
                "value": "MEDIUM"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "VULMON",
            "id": "CVE-2021-29072"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-004578"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202103-1354"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-29072"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-29072"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK852 before 3.2.17.12, RBK853 before 3.2.17.12, RBK854 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. This affects RBK852 prior to 3.2.17.12, RBK853 prior to 3.2.17.12, RBK854 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, and RBS850 prior to 3.2.17.12",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2021-29072"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-004578"
          },
          {
            "db": "VULMON",
            "id": "CVE-2021-29072"
          }
        ],
        "trust": 1.71
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2021-29072",
            "trust": 2.5
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-004578",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202103-1354",
            "trust": 0.6
          },
          {
            "db": "VULMON",
            "id": "CVE-2021-29072",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "VULMON",
            "id": "CVE-2021-29072"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-004578"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202103-1354"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-29072"
          }
        ]
      },
      "id": "VAR-202103-1275",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "VARIoT devices database",
            "id": null
          }
        ],
        "trust": 0.3648863
      },
      "last_update_date": "2024-11-23T23:07:37.983000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Security\u00a0Advisory\u00a0for\u00a0Post-Authentication\u00a0Command\u00a0Injection\u00a0on\u00a0Some\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0493",
            "trust": 0.8,
            "url": "https://kb.netgear.com/000063018/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0493"
          },
          {
            "title": "Certain NETGEAR Fixes for command injection vulnerabilities",
            "trust": 0.6,
            "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=144972"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-004578"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202103-1354"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-77",
            "trust": 1.0
          },
          {
            "problemtype": "Command injection (CWE-77) [NVD Evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-004578"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-29072"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.7,
            "url": "https://kb.netgear.com/000063018/security-advisory-for-post-authentication-command-injection-on-some-wifi-systems-psv-2020-0493"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2021-29072"
          },
          {
            "trust": 0.1,
            "url": "https://cwe.mitre.org/data/definitions/77.html"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov"
          }
        ],
        "sources": [
          {
            "db": "VULMON",
            "id": "CVE-2021-29072"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-004578"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202103-1354"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-29072"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "VULMON",
            "id": "CVE-2021-29072"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-004578"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202103-1354"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-29072"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2021-03-23T00:00:00",
            "db": "VULMON",
            "id": "CVE-2021-29072"
          },
          {
            "date": "2021-11-25T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2021-004578"
          },
          {
            "date": "2021-03-23T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202103-1354"
          },
          {
            "date": "2021-03-23T07:15:13.640000",
            "db": "NVD",
            "id": "CVE-2021-29072"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2021-03-24T00:00:00",
            "db": "VULMON",
            "id": "CVE-2021-29072"
          },
          {
            "date": "2021-11-25T03:10:00",
            "db": "JVNDB",
            "id": "JVNDB-2021-004578"
          },
          {
            "date": "2021-08-16T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202103-1354"
          },
          {
            "date": "2024-11-21T06:00:39.080000",
            "db": "NVD",
            "id": "CVE-2021-29072"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote or local",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202103-1354"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "plural \u00a0NETGEAR\u00a0 Command injection vulnerabilities in devices",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-004578"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "command injection",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202103-1354"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202112-2327

    Vulnerability from variot - Updated: 2024-11-23 23:07

    Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, EAX20 before 1.0.0.58, EAX80 before 1.0.1.68, EX7500 before 1.0.0.74, LAX20 before 1.1.6.28, MK62 before 1.0.6.116, MR60 before 1.0.6.116, MS60 before 1.0.6.116, R6400 before 1.0.1.70, R6400v2 before 1.0.4.118, R6700v3 before 1.0.4.118, R6900P before 1.3.3.140, R7000 before 1.0.11.116, R7000P before 1.3.3.140, R7850 before 1.0.5.68, R7900 before 1.0.4.38, R7900P before 1.4.2.84, R7960P before 1.4.2.84, R8000 before 1.0.4.68, R8000P before 1.4.2.84, RAX15 before 1.0.3.96, RAX20 before 1.0.3.96, RAX200 before 1.0.4.120, RAX35v2 before 1.0.3.96, RAX40v2 before 1.0.3.96, RAX43 before 1.0.3.96, RAX45 before 1.0.3.96, RAX50 before 1.0.3.96, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK752 before 3.2.17.12, RBK852 before 3.2.17.12, RBR750 before 3.2.17.12, RBR850 before 3.2.17.12, RBS750 before 3.2.17.12, RBS850 before 3.2.17.12, RS400 before 1.5.1.80, XR1000 before 1.0.0.58, and XR300 before 1.0.3.68. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects CBR40 prior to 2.5.0.24, CBR750 prior to 4.6.3.6, EAX20 prior to 1.0.0.58, EAX80 prior to 1.0.1.68, EX7500 prior to 1.0.0.74, LAX20 prior to 1.1.6.28, MK62 prior to 1.0.6.116, MR60 prior to 1.0.6.116, MS60 prior to 1.0.6.116, R6400 prior to 1.0.1.70, R6400v2 prior to 1.0.4.118, R6700v3 prior to 1.0.4.118, R6900P prior to 1.3.3.140, R7000 prior to 1.0.11.116, R7000P prior to 1.3.3.140, R7850 prior to 1.0.5.68, R7900 prior to 1.0.4.38, R7900P prior to 1.4.2.84, R7960P prior to 1.4.2.84, R8000 prior to 1.0.4.68, R8000P prior to 1.4.2.84, RAX15 prior to 1.0.3.96, RAX20 prior to 1.0.3.96, RAX200 prior to 1.0.4.120, RAX35v2 prior to 1.0.3.96, RAX40v2 prior to 1.0.3.96, RAX43 prior to 1.0.3.96, RAX45 prior to 1.0.3.96, RAX50 prior to 1.0.3.96, RAX75 prior to 1.0.4.120, RAX80 prior to 1.0.4.120, RBK752 prior to 3.2.17.12, RBK852 prior to 3.2.17.12, RBR750 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, RBS750 prior to 3.2.17.12, RBS850 prior to 3.2.17.12, RS400 prior to 1.5.1.80, XR1000 prior to 1.0.0.58, and XR300 prior to 1.0.3.68

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2327",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "rbr750",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.17.12"
          },
          {
            "model": "mr60",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.6.116"
          },
          {
            "model": "r6400",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.1.70"
          },
          {
            "model": "ms60",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.6.116"
          },
          {
            "model": "r8000",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.4.68"
          },
          {
            "model": "r8000p",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.4.2.84"
          },
          {
            "model": "rax15",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.3.96"
          },
          {
            "model": "r6400v2",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.4.118"
          },
          {
            "model": "rax45",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.3.96"
          },
          {
            "model": "rbk752",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.17.12"
          },
          {
            "model": "r7900p",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.4.2.84"
          },
          {
            "model": "eax20",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.0.58"
          },
          {
            "model": "rax43",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.3.96"
          },
          {
            "model": "eax80",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.1.68"
          },
          {
            "model": "rbr850",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.17.12"
          },
          {
            "model": "rax80",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.4.120"
          },
          {
            "model": "rs400",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.5.1.80"
          },
          {
            "model": "r7000p",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.3.3.140"
          },
          {
            "model": "rbs750",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.17.12"
          },
          {
            "model": "cbr40",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "2.5.0.24"
          },
          {
            "model": "cbr750",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "4.6.3.6"
          },
          {
            "model": "xr1000",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.0.58"
          },
          {
            "model": "rbs850",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.17.12"
          },
          {
            "model": "r7900",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.4.38"
          },
          {
            "model": "rax50",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.3.96"
          },
          {
            "model": "lax20",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.1.6.28"
          },
          {
            "model": "rax40v2",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.3.96"
          },
          {
            "model": "r6700v3",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.4.118"
          },
          {
            "model": "r6900p",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.3.3.140"
          },
          {
            "model": "rax35v2",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.3.96"
          },
          {
            "model": "rax200",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.4.120"
          },
          {
            "model": "rbk852",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.17.12"
          },
          {
            "model": "xr300",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.3.68"
          },
          {
            "model": "r7000",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.11.116"
          },
          {
            "model": "r7960p",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.4.2.84"
          },
          {
            "model": "rax75",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.4.120"
          },
          {
            "model": "mk62",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.6.116"
          },
          {
            "model": "ex7500",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.0.74"
          },
          {
            "model": "rax20",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.3.96"
          },
          {
            "model": "r7850",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.5.68"
          },
          {
            "model": "ex7500",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "r6400v2",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "mr60",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "eax20",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "cbr750",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "lax20",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "eax80",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "ms60",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "cbr40",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "mk62",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-017541"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45622"
          }
        ]
      },
      "cve": "CVE-2021-45622",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "COMPLETE",
                "baseScore": 10.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 10.0,
                "id": "CVE-2021-45622",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 1.8,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "id": "CVE-2021-45622",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT",
                "author": "cve@mitre.org",
                "availabilityImpact": "HIGH",
                "baseScore": 9.6,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.8,
                "id": "CVE-2021-45622",
                "impactScore": 6.0,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 9.8,
                "baseSeverity": "Critical",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "CVE-2021-45622",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2021-45622",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "cve@mitre.org",
                "id": "CVE-2021-45622",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "NVD",
                "id": "CVE-2021-45622",
                "trust": 0.8,
                "value": "Critical"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202112-2418",
                "trust": 0.6,
                "value": "CRITICAL"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-017541"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2418"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45622"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45622"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR40 before 2.5.0.24, CBR750 before 4.6.3.6, EAX20 before 1.0.0.58, EAX80 before 1.0.1.68, EX7500 before 1.0.0.74, LAX20 before 1.1.6.28, MK62 before 1.0.6.116, MR60 before 1.0.6.116, MS60 before 1.0.6.116, R6400 before 1.0.1.70, R6400v2 before 1.0.4.118, R6700v3 before 1.0.4.118, R6900P before 1.3.3.140, R7000 before 1.0.11.116, R7000P before 1.3.3.140, R7850 before 1.0.5.68, R7900 before 1.0.4.38, R7900P before 1.4.2.84, R7960P before 1.4.2.84, R8000 before 1.0.4.68, R8000P before 1.4.2.84, RAX15 before 1.0.3.96, RAX20 before 1.0.3.96, RAX200 before 1.0.4.120, RAX35v2 before 1.0.3.96, RAX40v2 before 1.0.3.96, RAX43 before 1.0.3.96, RAX45 before 1.0.3.96, RAX50 before 1.0.3.96, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK752 before 3.2.17.12, RBK852 before 3.2.17.12, RBR750 before 3.2.17.12, RBR850 before 3.2.17.12, RBS750 before 3.2.17.12, RBS850 before 3.2.17.12, RS400 before 1.5.1.80, XR1000 before 1.0.0.58, and XR300 before 1.0.3.68. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects CBR40 prior to 2.5.0.24, CBR750 prior to 4.6.3.6, EAX20 prior to 1.0.0.58, EAX80 prior to 1.0.1.68, EX7500 prior to 1.0.0.74, LAX20 prior to 1.1.6.28, MK62 prior to 1.0.6.116, MR60 prior to 1.0.6.116, MS60 prior to 1.0.6.116, R6400 prior to 1.0.1.70, R6400v2 prior to 1.0.4.118, R6700v3 prior to 1.0.4.118, R6900P prior to 1.3.3.140, R7000 prior to 1.0.11.116, R7000P prior to 1.3.3.140, R7850 prior to 1.0.5.68, R7900 prior to 1.0.4.38, R7900P prior to 1.4.2.84, R7960P prior to 1.4.2.84, R8000 prior to 1.0.4.68, R8000P prior to 1.4.2.84, RAX15 prior to 1.0.3.96, RAX20 prior to 1.0.3.96, RAX200 prior to 1.0.4.120, RAX35v2 prior to 1.0.3.96, RAX40v2 prior to 1.0.3.96, RAX43 prior to 1.0.3.96, RAX45 prior to 1.0.3.96, RAX50 prior to 1.0.3.96, RAX75 prior to 1.0.4.120, RAX80 prior to 1.0.4.120, RBK752 prior to 3.2.17.12, RBK852 prior to 3.2.17.12, RBR750 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, RBS750 prior to 3.2.17.12, RBS850 prior to 3.2.17.12, RS400 prior to 1.5.1.80, XR1000 prior to 1.0.0.58, and XR300 prior to 1.0.3.68",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2021-45622"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-017541"
          },
          {
            "db": "VULMON",
            "id": "CVE-2021-45622"
          }
        ],
        "trust": 1.71
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2021-45622",
            "trust": 3.3
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-017541",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2418",
            "trust": 0.6
          },
          {
            "db": "VULMON",
            "id": "CVE-2021-45622",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "VULMON",
            "id": "CVE-2021-45622"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-017541"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2418"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45622"
          }
        ]
      },
      "id": "VAR-202112-2327",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "VARIoT devices database",
            "id": null
          }
        ],
        "trust": 0.3053594013333333
      },
      "last_update_date": "2024-11-23T23:07:30.624000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Security\u00a0Advisory\u00a0for\u00a0Pre-Authentication\u00a0Command\u00a0Injection\u00a0on\u00a0Some\u00a0Routers,\u00a0Extenders,\u00a0and\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0506",
            "trust": 0.8,
            "url": "https://kb.netgear.com/000064499/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2020-0506"
          },
          {
            "title": "Netgear RBR750  and NETGEAR Security vulnerabilities",
            "trust": 0.6,
            "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=176397"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-017541"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2418"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-77",
            "trust": 1.0
          },
          {
            "problemtype": "Command injection (CWE-77) [NVD evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-017541"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45622"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.7,
            "url": "https://kb.netgear.com/000064509/security-advisory-for-pre-authentication-command-injection-on-some-routers-extender-wifi-systems-psv-2020-0506"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45622"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov"
          }
        ],
        "sources": [
          {
            "db": "VULMON",
            "id": "CVE-2021-45622"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-017541"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2418"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45622"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "VULMON",
            "id": "CVE-2021-45622"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-017541"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2418"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45622"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2021-12-26T00:00:00",
            "db": "VULMON",
            "id": "CVE-2021-45622"
          },
          {
            "date": "2023-01-25T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2021-017541"
          },
          {
            "date": "2021-12-26T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202112-2418"
          },
          {
            "date": "2021-12-26T01:15:18.810000",
            "db": "NVD",
            "id": "CVE-2021-45622"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2021-12-27T00:00:00",
            "db": "VULMON",
            "id": "CVE-2021-45622"
          },
          {
            "date": "2023-01-25T02:01:00",
            "db": "JVNDB",
            "id": "JVNDB-2021-017541"
          },
          {
            "date": "2022-01-11T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202112-2418"
          },
          {
            "date": "2024-11-21T06:32:42.160000",
            "db": "NVD",
            "id": "CVE-2021-45622"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2418"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "plural \u00a0NETGEAR\u00a0 Command injection vulnerability in device",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-017541"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "command injection",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2418"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202112-2369

    Vulnerability from variot - Updated: 2024-11-23 23:07

    Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects RBK752 prior to 3.2.16.6, RBR750 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBK852 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, and RBS850 prior to 3.2.16.6

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2369",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "rbr850",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.16.6"
          },
          {
            "model": "rbk752",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.16.6"
          },
          {
            "model": "rbr750",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.16.6"
          },
          {
            "model": "rbk852",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.16.6"
          },
          {
            "model": "rbs850",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.16.6"
          },
          {
            "model": "rbs750",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.16.6"
          },
          {
            "model": "rbk752",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rbr750",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rbs750",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rbr850",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rbs850",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rbk852",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-016889"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45579"
          }
        ]
      },
      "cve": "CVE-2021-45579",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "ADJACENT_NETWORK",
                "authentication": "SINGLE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "PARTIAL",
                "baseScore": 5.2,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 5.1,
                "id": "CVE-2021-45579",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 1.9,
                "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 6.8,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 0.9,
                "id": "CVE-2021-45579",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT",
                "author": "cve@mitre.org",
                "availabilityImpact": "HIGH",
                "baseScore": 8.4,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 1.7,
                "id": "CVE-2021-45579",
                "impactScore": 6.0,
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Adjacent Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 6.8,
                "baseSeverity": "Medium",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "CVE-2021-45579",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "High",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2021-45579",
                "trust": 1.0,
                "value": "MEDIUM"
              },
              {
                "author": "cve@mitre.org",
                "id": "CVE-2021-45579",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "NVD",
                "id": "CVE-2021-45579",
                "trust": 0.8,
                "value": "Medium"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202112-2373",
                "trust": 0.6,
                "value": "MEDIUM"
              },
              {
                "author": "VULMON",
                "id": "CVE-2021-45579",
                "trust": 0.1,
                "value": "MEDIUM"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "VULMON",
            "id": "CVE-2021-45579"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-016889"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2373"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45579"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45579"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects RBK752 prior to 3.2.16.6, RBR750 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBK852 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, and RBS850 prior to 3.2.16.6",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2021-45579"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-016889"
          },
          {
            "db": "VULMON",
            "id": "CVE-2021-45579"
          }
        ],
        "trust": 1.71
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2021-45579",
            "trust": 3.3
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-016889",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2373",
            "trust": 0.6
          },
          {
            "db": "VULMON",
            "id": "CVE-2021-45579",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "VULMON",
            "id": "CVE-2021-45579"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-016889"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2373"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45579"
          }
        ]
      },
      "id": "VAR-202112-2369",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "VARIoT devices database",
            "id": null
          }
        ],
        "trust": 0.14124016
      },
      "last_update_date": "2024-11-23T23:07:30.575000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Security\u00a0Advisory\u00a0for\u00a0Post-Authentication\u00a0Command\u00a0Injection\u00a0on\u00a0Some\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0087",
            "trust": 0.8,
            "url": "https://kb.netgear.com/000064101/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0087"
          },
          {
            "title": "Netgear NETGEAR Fixes for command injection vulnerabilities",
            "trust": 0.6,
            "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=177080"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-016889"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2373"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-77",
            "trust": 1.0
          },
          {
            "problemtype": "Command injection (CWE-77) [NVD evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-016889"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45579"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.7,
            "url": "https://kb.netgear.com/000064101/security-advisory-for-post-authentication-command-injection-on-some-wifi-systems-psv-2020-0087"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45579"
          },
          {
            "trust": 0.1,
            "url": "https://cwe.mitre.org/data/definitions/77.html"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov"
          }
        ],
        "sources": [
          {
            "db": "VULMON",
            "id": "CVE-2021-45579"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-016889"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2373"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45579"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "VULMON",
            "id": "CVE-2021-45579"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-016889"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2373"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45579"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2021-12-26T00:00:00",
            "db": "VULMON",
            "id": "CVE-2021-45579"
          },
          {
            "date": "2022-12-26T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2021-016889"
          },
          {
            "date": "2021-12-26T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202112-2373"
          },
          {
            "date": "2021-12-26T01:15:16.747000",
            "db": "NVD",
            "id": "CVE-2021-45579"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2022-01-04T00:00:00",
            "db": "VULMON",
            "id": "CVE-2021-45579"
          },
          {
            "date": "2022-12-26T06:09:00",
            "db": "JVNDB",
            "id": "JVNDB-2021-016889"
          },
          {
            "date": "2022-01-05T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202112-2373"
          },
          {
            "date": "2024-11-21T06:32:34.577000",
            "db": "NVD",
            "id": "CVE-2021-45579"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote or local",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2373"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "plural \u00a0NETGEAR\u00a0 Command injection vulnerability in device",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-016889"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "command injection",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2373"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202112-2390

    Vulnerability from variot - Updated: 2024-11-23 23:07

    Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects RBK752 prior to 3.2.16.6, RBR750 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBK852 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, and RBS850 prior to 3.2.16.6

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2390",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "rbr850",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.16.6"
          },
          {
            "model": "rbk752",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.16.6"
          },
          {
            "model": "rbr750",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.16.6"
          },
          {
            "model": "rbk852",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.16.6"
          },
          {
            "model": "rbs850",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.16.6"
          },
          {
            "model": "rbs750",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.16.6"
          },
          {
            "model": "rbr750",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rbk752",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rbr850",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rbs750",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rbk852",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rbs850",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-016921"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45558"
          }
        ]
      },
      "cve": "CVE-2021-45558",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "ADJACENT_NETWORK",
                "authentication": "SINGLE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "PARTIAL",
                "baseScore": 5.2,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 5.1,
                "id": "CVE-2021-45558",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 1.9,
                "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 6.8,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 0.9,
                "id": "CVE-2021-45558",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT",
                "author": "cve@mitre.org",
                "availabilityImpact": "HIGH",
                "baseScore": 8.4,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 1.7,
                "id": "CVE-2021-45558",
                "impactScore": 6.0,
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Adjacent Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 6.8,
                "baseSeverity": "Medium",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "CVE-2021-45558",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "High",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2021-45558",
                "trust": 1.0,
                "value": "MEDIUM"
              },
              {
                "author": "cve@mitre.org",
                "id": "CVE-2021-45558",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "NVD",
                "id": "CVE-2021-45558",
                "trust": 0.8,
                "value": "Medium"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202112-2291",
                "trust": 0.6,
                "value": "MEDIUM"
              },
              {
                "author": "VULMON",
                "id": "CVE-2021-45558",
                "trust": 0.1,
                "value": "MEDIUM"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "VULMON",
            "id": "CVE-2021-45558"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-016921"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2291"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45558"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45558"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects RBK752 prior to 3.2.16.6, RBR750 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBK852 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, and RBS850 prior to 3.2.16.6",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2021-45558"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-016921"
          },
          {
            "db": "VULMON",
            "id": "CVE-2021-45558"
          }
        ],
        "trust": 1.71
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2021-45558",
            "trust": 3.3
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-016921",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2291",
            "trust": 0.6
          },
          {
            "db": "VULMON",
            "id": "CVE-2021-45558",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "VULMON",
            "id": "CVE-2021-45558"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-016921"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2291"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45558"
          }
        ]
      },
      "id": "VAR-202112-2390",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "VARIoT devices database",
            "id": null
          }
        ],
        "trust": 0.14124016
      },
      "last_update_date": "2024-11-23T23:07:30.551000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Security\u00a0Advisory\u00a0for\u00a0Post-Authentication\u00a0Command\u00a0Injection\u00a0on\u00a0Some\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0053",
            "trust": 0.8,
            "url": "https://kb.netgear.com/000064078/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0053"
          },
          {
            "title": "Netgear NETGEAR Fixes for command injection vulnerabilities",
            "trust": 0.6,
            "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=177053"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-016921"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2291"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-77",
            "trust": 1.0
          },
          {
            "problemtype": "Command injection (CWE-77) [NVD evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-016921"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45558"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.7,
            "url": "https://kb.netgear.com/000064078/security-advisory-for-post-authentication-command-injection-on-some-wifi-systems-psv-2020-0053"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45558"
          },
          {
            "trust": 0.1,
            "url": "https://cwe.mitre.org/data/definitions/77.html"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov"
          }
        ],
        "sources": [
          {
            "db": "VULMON",
            "id": "CVE-2021-45558"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-016921"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2291"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45558"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "VULMON",
            "id": "CVE-2021-45558"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-016921"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2291"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45558"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2021-12-26T00:00:00",
            "db": "VULMON",
            "id": "CVE-2021-45558"
          },
          {
            "date": "2022-12-27T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2021-016921"
          },
          {
            "date": "2021-12-25T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202112-2291"
          },
          {
            "date": "2021-12-26T01:15:15.757000",
            "db": "NVD",
            "id": "CVE-2021-45558"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2022-01-04T00:00:00",
            "db": "VULMON",
            "id": "CVE-2021-45558"
          },
          {
            "date": "2022-12-27T02:56:00",
            "db": "JVNDB",
            "id": "JVNDB-2021-016921"
          },
          {
            "date": "2022-01-05T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202112-2291"
          },
          {
            "date": "2024-11-21T06:32:30.990000",
            "db": "NVD",
            "id": "CVE-2021-45558"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote or local",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2291"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "plural \u00a0NETGEAR\u00a0 Command injection vulnerability in device",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-016921"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "command injection",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2291"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202112-2411

    Vulnerability from variot - Updated: 2024-11-23 23:07

    Certain NETGEAR devices are affected by command injection by an authenticated user . This affects RAX200 before 1.0.3.106, RAX75 before 1.0.3.106, RAX80 before 1.0.3.106, RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects RAX200 prior to 1.0.3.106, RAX75 prior to 1.0.3.106, RAX80 prior to 1.0.3.106, RBK752 prior to 3.2.16.6, RBR750 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBK852 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, and RBS850 prior to 3.2.16.6

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2411",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "rbk752",
            "scope": "eq",
            "trust": 1.0,
            "vendor": "netgear",
            "version": null
          },
          {
            "model": "rax75",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.3.106"
          },
          {
            "model": "rbs750",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.16.6"
          },
          {
            "model": "rbr850",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.16.6"
          },
          {
            "model": "rbr750",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.16.6"
          },
          {
            "model": "rbk852",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.16.6"
          },
          {
            "model": "rax200",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.3.106"
          },
          {
            "model": "rbs850",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.16.6"
          },
          {
            "model": "rax80",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.3.106"
          },
          {
            "model": "rbr750",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rbk752",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rbr850",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rax80",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rax75",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rax200",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rbs750",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rbk852",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rbs850",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-016942"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45537"
          }
        ]
      },
      "cve": "CVE-2021-45537",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "ADJACENT_NETWORK",
                "authentication": "SINGLE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "PARTIAL",
                "baseScore": 5.2,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 5.1,
                "id": "CVE-2021-45537",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 1.9,
                "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 6.8,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 0.9,
                "id": "CVE-2021-45537",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT",
                "author": "cve@mitre.org",
                "availabilityImpact": "HIGH",
                "baseScore": 8.4,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 1.7,
                "id": "CVE-2021-45537",
                "impactScore": 6.0,
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Adjacent Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 6.8,
                "baseSeverity": "Medium",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "CVE-2021-45537",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "High",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2021-45537",
                "trust": 1.0,
                "value": "MEDIUM"
              },
              {
                "author": "cve@mitre.org",
                "id": "CVE-2021-45537",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "NVD",
                "id": "CVE-2021-45537",
                "trust": 0.8,
                "value": "Medium"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202112-2353",
                "trust": 0.6,
                "value": "MEDIUM"
              },
              {
                "author": "VULMON",
                "id": "CVE-2021-45537",
                "trust": 0.1,
                "value": "MEDIUM"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "VULMON",
            "id": "CVE-2021-45537"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-016942"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2353"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45537"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45537"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Certain NETGEAR devices are affected by command injection by an authenticated user . This affects RAX200 before 1.0.3.106, RAX75 before 1.0.3.106, RAX80 before 1.0.3.106, RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects RAX200 prior to 1.0.3.106, RAX75 prior to 1.0.3.106, RAX80 prior to 1.0.3.106, RBK752 prior to 3.2.16.6, RBR750 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBK852 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, and RBS850 prior to 3.2.16.6",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2021-45537"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-016942"
          },
          {
            "db": "VULMON",
            "id": "CVE-2021-45537"
          }
        ],
        "trust": 1.71
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2021-45537",
            "trust": 3.3
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-016942",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2353",
            "trust": 0.6
          },
          {
            "db": "VULMON",
            "id": "CVE-2021-45537",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "VULMON",
            "id": "CVE-2021-45537"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-016942"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2353"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45537"
          }
        ]
      },
      "id": "VAR-202112-2411",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "VARIoT devices database",
            "id": null
          }
        ],
        "trust": 0.14124016
      },
      "last_update_date": "2024-11-23T23:07:30.527000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Security\u00a0Advisory\u00a0for\u00a0Post-Authentication\u00a0Command\u00a0Injection\u00a0on\u00a0Some\u00a0Routers\u00a0and\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0061",
            "trust": 0.8,
            "url": "https://kb.netgear.com/000064083/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2020-0061"
          },
          {
            "title": "Netgear RBR750  and NETGEAR Fixes for command injection vulnerabilities",
            "trust": 0.6,
            "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=177115"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-016942"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2353"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-77",
            "trust": 1.0
          },
          {
            "problemtype": "Command injection (CWE-77) [NVD evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-016942"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45537"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.7,
            "url": "https://kb.netgear.com/000064083/security-advisory-for-post-authentication-command-injection-on-some-routers-and-wifi-systems-psv-2020-0061"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45537"
          },
          {
            "trust": 0.1,
            "url": "https://cwe.mitre.org/data/definitions/77.html"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov"
          }
        ],
        "sources": [
          {
            "db": "VULMON",
            "id": "CVE-2021-45537"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-016942"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2353"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45537"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "VULMON",
            "id": "CVE-2021-45537"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-016942"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2353"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45537"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2021-12-26T00:00:00",
            "db": "VULMON",
            "id": "CVE-2021-45537"
          },
          {
            "date": "2022-12-27T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2021-016942"
          },
          {
            "date": "2021-12-26T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202112-2353"
          },
          {
            "date": "2021-12-26T01:15:14.747000",
            "db": "NVD",
            "id": "CVE-2021-45537"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2022-01-04T00:00:00",
            "db": "VULMON",
            "id": "CVE-2021-45537"
          },
          {
            "date": "2022-12-27T04:48:00",
            "db": "JVNDB",
            "id": "JVNDB-2021-016942"
          },
          {
            "date": "2022-01-10T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202112-2353"
          },
          {
            "date": "2024-11-21T06:32:27.310000",
            "db": "NVD",
            "id": "CVE-2021-45537"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote or local",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2353"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "plural \u00a0NETGEAR\u00a0 Command injection vulnerability in device",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-016942"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "command injection",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2353"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202103-1271

    Vulnerability from variot - Updated: 2024-11-23 23:04

    Certain NETGEAR devices are affected by a buffer overflow by an authenticated user. This affects R6700v3 before 1.0.4.98, R6400v2 before 1.0.4.98, R7000 before 1.0.11.106, R6900P before 1.3.2.124, R7000P before 1.3.2.124, R7900 before 1.0.4.26, R7850 before 1.0.5.60, R8000 before 1.0.4.58, RS400 before 1.5.0.48, R6400 before 1.0.1.62, R6700 before 1.0.2.16, R6900 before 1.0.2.16, MK60 before 1.0.5.102, MR60 before 1.0.5.102, MS60 before 1.0.5.102, CBR40 before 2.5.0.10, R8000P before 1.4.1.62, R7960P before 1.4.1.62, R7900P before 1.4.1.62, RAX15 before 1.0.1.64, RAX20 before 1.0.1.64, RAX75 before 1.0.3.102, RAX80 before 1.0.3.102, RAX200 before 1.0.2.102, RAX45 before 1.0.2.64, RAX50 before 1.0.2.64, EX7500 before 1.0.0.68, EAX80 before 1.0.1.62, EAX20 before 1.0.0.36, RBK752 before 3.2.16.6, RBK753 before 3.2.16.6, RBK753S before 3.2.16.6, RBK754 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBK853 before 3.2.16.6, RBK854 before 3.2.16.6, RBR850 before 3.2.16.6, RBS850 before 3.2.16.6, RBR840 before 3.2.16.6, RBS840 before 3.2.16.6, R6120 before 1.0.0.70, R6220 before 1.1.0.100, R6230 before 1.1.0.100, R6260 before 1.1.0.76, R6850 before 1.1.0.76, R6350 before 1.1.0.76, R6330 before 1.1.0.76, D7800 before 1.0.1.58, RBK50 before 2.6.1.40, RBR50 before 2.6.1.40, RBS50 before 2.6.1.40, RBK40 before 2.6.1.36, RBR40 before 2.6.1.36, RBS40 before 2.6.1.38, RBK23 before 2.6.1.36, RBR20 before 2.6.1.38, RBS20 before 2.6.1.38, RBK12 before 2.6.1.44, RBK13 before 2.6.1.44, RBK14 before 2.6.1.44, RBK15 before 2.6.1.44, RBR10 before 2.6.1.44, RBS10 before 2.6.1.44, R6800 before 1.2.0.72, R6900v2 before 1.2.0.72, R6700v2 before 1.2.0.72, R7200 before 1.2.0.72, R7350 before 1.2.0.72, R7400 before 1.2.0.72, R7450 before 1.2.0.72, AC2100 before 1.2.0.72, AC2400 before 1.2.0.72, AC2600 before 1.2.0.72, R7800 before 1.0.2.74, R8900 before 1.0.5.24, R9000 before 1.0.5.24, RAX120 before 1.0.1.136, XR450 before 2.3.2.66, XR500 before 2.3.2.66, XR700 before 1.0.1.34, and XR300 before 1.0.3.50. plural NETGEAR A classic buffer overflow vulnerability exists in the device.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. This affects R6700v3 prior to 1.0.4.98, R6400v2 prior to 1.0.4.98, R7000 prior to 1.0.11.106, R6900P prior to 1.3.2.124, R7000P prior to 1.3.2.124, R7900 prior to 1.0.4.26, R7850 prior to 1.0.5.60, R8000 prior to 1.0.4.58, RS400 prior to 1.5.0.48, R6400 prior to 1.0.1.62, R6700 prior to 1.0.2.16, R6900 prior to 1.0.2.16, MK60 prior to 1.0.5.102, MR60 prior to 1.0.5.102, MS60 prior to 1.0.5.102, CBR40 prior to 2.5.0.10, R8000P prior to 1.4.1.62, R7960P prior to 1.4.1.62, R7900P prior to 1.4.1.62, RAX15 prior to 1.0.1.64, RAX20 prior to 1.0.1.64, RAX75 prior to 1.0.3.102, RAX80 prior to 1.0.3.102, RAX200 prior to 1.0.2.102, RAX45 prior to 1.0.2.64, RAX50 prior to 1.0.2.64, EX7500 prior to 1.0.0.68, EAX80 prior to 1.0.1.62, EAX20 prior to 1.0.0.36, RBK752 prior to 3.2.16.6, RBK753 prior to 3.2.16.6, RBK753S prior to 3.2.16.6, RBK754 prior to 3.2.16.6, RBR750 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBK852 prior to 3.2.16.6, RBK853 prior to 3.2.16.6, RBK854 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, RBS850 prior to 3.2.16.6, RBR840 prior to 3.2.16.6, RBS840 prior to 3.2.16.6, R6120 prior to 1.0.0.70, R6220 prior to 1.1.0.100, R6230 prior to 1.1.0.100, R6260 prior to 1.1.0.76, R6850 prior to 1.1.0.76, R6350 prior to 1.1.0.76, R6330 prior to 1.1.0.76, D7800 prior to 1.0.1.58, RBK50 prior to 2.6.1.40, RBR50 prior to 2.6.1.40, RBS50 prior to 2.6.1.40, RBK40 prior to 2.6.1.36, RBR40 prior to 2.6.1.36, RBS40 prior to 2.6.1.38, RBK23 prior to 2.6.1.36, RBR20 prior to 2.6.1.38, RBS20 prior to 2.6.1.38, RBK12 prior to 2.6.1.44, RBK13 prior to 2.6.1.44, RBK14 prior to 2.6.1.44, RBK15 prior to 2.6.1.44, RBR10 prior to 2.6.1.44, RBS10 prior to 2.6.1.44, R6800 prior to 1.2.0.72, R6900v2 prior to 1.2.0.72, R6700v2 prior to 1.2.0.72, R7200 prior to 1.2.0.72, R7350 prior to 1.2.0.72, R7400 prior to 1.2.0.72, R7450 prior to 1.2.0.72, AC2100 prior to 1.2.0.72, AC2400 prior to 1.2.0.72, AC2600 prior to 1.2.0.72, R7800 prior to 1.0.2.74, R8900 prior to 1.0.5.24, R9000 prior to 1.0.5.24, RAX120 prior to 1.0.1.136, XR450 prior to 2.3.2.66, XR500 prior to 2.3.2.66, XR700 prior to 1.0.1.34, and XR300 prior to 1.0.3.50

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202103-1271",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "r6900",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.2.0.72"
          },
          {
            "model": "ms60",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.5.102"
          },
          {
            "model": "rax200",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.2.102"
          },
          {
            "model": "r7400",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.2.0.72"
          },
          {
            "model": "rbr50",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "2.6.1.40"
          },
          {
            "model": "r6900",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.2.16"
          },
          {
            "model": "r7350",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.2.0.72"
          },
          {
            "model": "rbs850",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.16.6"
          },
          {
            "model": "rbk50",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "2.6.1.40"
          },
          {
            "model": "rbk12",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "2.6.1.44"
          },
          {
            "model": "rbs750",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.16.6"
          },
          {
            "model": "rbr40",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "2.6.1.36"
          },
          {
            "model": "rbs10",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "2.6.1.44"
          },
          {
            "model": "rax120",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.1.136"
          },
          {
            "model": "rax75",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.3.102"
          },
          {
            "model": "r9000",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.5.24"
          },
          {
            "model": "rbk854",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.16.6"
          },
          {
            "model": "eax80",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.1.62"
          },
          {
            "model": "r7800",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.2.74"
          },
          {
            "model": "r7900",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.4.26"
          },
          {
            "model": "ac2100",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.2.0.72"
          },
          {
            "model": "rbk753",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.16.6"
          },
          {
            "model": "xr300",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.3.50"
          },
          {
            "model": "d7800",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.1.58"
          },
          {
            "model": "rax50",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.2.64"
          },
          {
            "model": "rbr20",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "2.6.1.38"
          },
          {
            "model": "r6260",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.1.0.76"
          },
          {
            "model": "r8900",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.5.24"
          },
          {
            "model": "rbk14",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "2.6.1.44"
          },
          {
            "model": "r6120",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.0.70"
          },
          {
            "model": "xr700",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.1.34"
          },
          {
            "model": "ex7500",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.0.68"
          },
          {
            "model": "rbk23",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "2.6.1.36"
          },
          {
            "model": "xr500",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "2.3.2.66"
          },
          {
            "model": "rbr840",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.16.6"
          },
          {
            "model": "r7960p",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.4.1.62"
          },
          {
            "model": "rbk15",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "2.6.1.44"
          },
          {
            "model": "ac2600",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.2.0.72"
          },
          {
            "model": "rbs50",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "2.6.1.40"
          },
          {
            "model": "rax20",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.1.64"
          },
          {
            "model": "rbs20",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "2.6.1.38"
          },
          {
            "model": "cbr40",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "2.5.0.10"
          },
          {
            "model": "ac2400",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.2.0.72"
          },
          {
            "model": "rbr850",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.16.6"
          },
          {
            "model": "r6220",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.0.70"
          },
          {
            "model": "r6330",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.1.0.76"
          },
          {
            "model": "rbk852",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.16.6"
          },
          {
            "model": "r8000p",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.4.1.62"
          },
          {
            "model": "rbk853",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.16.6"
          },
          {
            "model": "r6900p",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.3.2.124"
          },
          {
            "model": "r6800",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.2.0.72"
          },
          {
            "model": "xr450",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "2.3.2.66"
          },
          {
            "model": "r6400",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.4.98"
          },
          {
            "model": "rs400",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.5.0.48"
          },
          {
            "model": "r6350",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.1.0.76"
          },
          {
            "model": "r6700",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.4.98"
          },
          {
            "model": "r7000",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.11.106"
          },
          {
            "model": "rbk13",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "2.6.1.44"
          },
          {
            "model": "r7850",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.5.60"
          },
          {
            "model": "r6400",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.1.62"
          },
          {
            "model": "mr60",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.5.102"
          },
          {
            "model": "eax20",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.0.36"
          },
          {
            "model": "rbk842",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.16.6"
          },
          {
            "model": "rbr750",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.16.6"
          },
          {
            "model": "r7200",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.2.0.72"
          },
          {
            "model": "r6700",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.2.0.72"
          },
          {
            "model": "r8000",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.4.58"
          },
          {
            "model": "rax80",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.3.102"
          },
          {
            "model": "rbk754",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.16.6"
          },
          {
            "model": "r6700",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.2.16"
          },
          {
            "model": "rax45",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.2.64"
          },
          {
            "model": "rbk753s",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.16.6"
          },
          {
            "model": "r6230",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.0.70"
          },
          {
            "model": "rbs40",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "2.6.1.38"
          },
          {
            "model": "rax15",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.1.64"
          },
          {
            "model": "rbk752",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.16.6"
          },
          {
            "model": "r6850",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.1.0.76"
          },
          {
            "model": "rbk40",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "2.6.1.36"
          },
          {
            "model": "r7450",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.2.0.72"
          },
          {
            "model": "rbs840",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.16.6"
          },
          {
            "model": "r7900p",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.4.1.62"
          },
          {
            "model": "r7000p",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.3.2.124"
          },
          {
            "model": "mk60",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.5.102"
          },
          {
            "model": "rbr10",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "2.6.1.44"
          },
          {
            "model": "r6900p",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "r7000p",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "r7000",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "r7850",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "r6400",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "r7900",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "r8000",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "r6700",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-005326"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-29068"
          }
        ]
      },
      "cve": "CVE-2021-29068",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "PARTIAL",
                "baseScore": 6.5,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 8.0,
                "id": "CVE-2021-29068",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 1.9,
                "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.8,
                "id": "CVE-2021-29068",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "cve@mitre.org",
                "availabilityImpact": "HIGH",
                "baseScore": 9.9,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.1,
                "id": "CVE-2021-29068",
                "impactScore": 6.0,
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "CHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 8.8,
                "baseSeverity": "High",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "CVE-2021-29068",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "Low",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2021-29068",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "cve@mitre.org",
                "id": "CVE-2021-29068",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "NVD",
                "id": "CVE-2021-29068",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202103-1360",
                "trust": 0.6,
                "value": "HIGH"
              },
              {
                "author": "VULMON",
                "id": "CVE-2021-29068",
                "trust": 0.1,
                "value": "MEDIUM"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "VULMON",
            "id": "CVE-2021-29068"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-005326"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202103-1360"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-29068"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-29068"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Certain NETGEAR devices are affected by a buffer overflow by an authenticated user. This affects R6700v3 before 1.0.4.98, R6400v2 before 1.0.4.98, R7000 before 1.0.11.106, R6900P before 1.3.2.124, R7000P before 1.3.2.124, R7900 before 1.0.4.26, R7850 before 1.0.5.60, R8000 before 1.0.4.58, RS400 before 1.5.0.48, R6400 before 1.0.1.62, R6700 before 1.0.2.16, R6900 before 1.0.2.16, MK60 before 1.0.5.102, MR60 before 1.0.5.102, MS60 before 1.0.5.102, CBR40 before 2.5.0.10, R8000P before 1.4.1.62, R7960P before 1.4.1.62, R7900P before 1.4.1.62, RAX15 before 1.0.1.64, RAX20 before 1.0.1.64, RAX75 before 1.0.3.102, RAX80 before 1.0.3.102, RAX200 before 1.0.2.102, RAX45 before 1.0.2.64, RAX50 before 1.0.2.64, EX7500 before 1.0.0.68, EAX80 before 1.0.1.62, EAX20 before 1.0.0.36, RBK752 before 3.2.16.6, RBK753 before 3.2.16.6, RBK753S before 3.2.16.6, RBK754 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBK853 before 3.2.16.6, RBK854 before 3.2.16.6, RBR850 before 3.2.16.6, RBS850 before 3.2.16.6, RBR840 before 3.2.16.6, RBS840 before 3.2.16.6, R6120 before 1.0.0.70, R6220 before 1.1.0.100, R6230 before 1.1.0.100, R6260 before 1.1.0.76, R6850 before 1.1.0.76, R6350 before 1.1.0.76, R6330 before 1.1.0.76, D7800 before 1.0.1.58, RBK50 before 2.6.1.40, RBR50 before 2.6.1.40, RBS50 before 2.6.1.40, RBK40 before 2.6.1.36, RBR40 before 2.6.1.36, RBS40 before 2.6.1.38, RBK23 before 2.6.1.36, RBR20 before 2.6.1.38, RBS20 before 2.6.1.38, RBK12 before 2.6.1.44, RBK13 before 2.6.1.44, RBK14 before 2.6.1.44, RBK15 before 2.6.1.44, RBR10 before 2.6.1.44, RBS10 before 2.6.1.44, R6800 before 1.2.0.72, R6900v2 before 1.2.0.72, R6700v2 before 1.2.0.72, R7200 before 1.2.0.72, R7350 before 1.2.0.72, R7400 before 1.2.0.72, R7450 before 1.2.0.72, AC2100 before 1.2.0.72, AC2400 before 1.2.0.72, AC2600 before 1.2.0.72, R7800 before 1.0.2.74, R8900 before 1.0.5.24, R9000 before 1.0.5.24, RAX120 before 1.0.1.136, XR450 before 2.3.2.66, XR500 before 2.3.2.66, XR700 before 1.0.1.34, and XR300 before 1.0.3.50. plural NETGEAR A classic buffer overflow vulnerability exists in the device.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. This affects R6700v3 prior to 1.0.4.98, R6400v2 prior to 1.0.4.98, R7000 prior to 1.0.11.106, R6900P prior to 1.3.2.124, R7000P prior to 1.3.2.124, R7900 prior to 1.0.4.26, R7850 prior to 1.0.5.60, R8000 prior to 1.0.4.58, RS400 prior to 1.5.0.48, R6400 prior to 1.0.1.62, R6700 prior to 1.0.2.16, R6900 prior to 1.0.2.16, MK60 prior to 1.0.5.102, MR60 prior to 1.0.5.102, MS60 prior to 1.0.5.102, CBR40 prior to 2.5.0.10, R8000P prior to 1.4.1.62, R7960P prior to 1.4.1.62, R7900P prior to 1.4.1.62, RAX15 prior to 1.0.1.64, RAX20 prior to 1.0.1.64, RAX75 prior to 1.0.3.102, RAX80 prior to 1.0.3.102, RAX200 prior to 1.0.2.102, RAX45 prior to 1.0.2.64, RAX50 prior to 1.0.2.64, EX7500 prior to 1.0.0.68, EAX80 prior to 1.0.1.62, EAX20 prior to 1.0.0.36, RBK752 prior to 3.2.16.6, RBK753 prior to 3.2.16.6, RBK753S prior to 3.2.16.6, RBK754 prior to 3.2.16.6, RBR750 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBK852 prior to 3.2.16.6, RBK853 prior to 3.2.16.6, RBK854 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, RBS850 prior to 3.2.16.6, RBR840 prior to 3.2.16.6, RBS840 prior to 3.2.16.6, R6120 prior to 1.0.0.70, R6220 prior to 1.1.0.100, R6230 prior to 1.1.0.100, R6260 prior to 1.1.0.76, R6850 prior to 1.1.0.76, R6350 prior to 1.1.0.76, R6330 prior to 1.1.0.76, D7800 prior to 1.0.1.58, RBK50 prior to 2.6.1.40, RBR50 prior to 2.6.1.40, RBS50 prior to 2.6.1.40, RBK40 prior to 2.6.1.36, RBR40 prior to 2.6.1.36, RBS40 prior to 2.6.1.38, RBK23 prior to 2.6.1.36, RBR20 prior to 2.6.1.38, RBS20 prior to 2.6.1.38, RBK12 prior to 2.6.1.44, RBK13 prior to 2.6.1.44, RBK14 prior to 2.6.1.44, RBK15 prior to 2.6.1.44, RBR10 prior to 2.6.1.44, RBS10 prior to 2.6.1.44, R6800 prior to 1.2.0.72, R6900v2 prior to 1.2.0.72, R6700v2 prior to 1.2.0.72, R7200 prior to 1.2.0.72, R7350 prior to 1.2.0.72, R7400 prior to 1.2.0.72, R7450 prior to 1.2.0.72, AC2100 prior to 1.2.0.72, AC2400 prior to 1.2.0.72, AC2600 prior to 1.2.0.72, R7800 prior to 1.0.2.74, R8900 prior to 1.0.5.24, R9000 prior to 1.0.5.24, RAX120 prior to 1.0.1.136, XR450 prior to 2.3.2.66, XR500 prior to 2.3.2.66, XR700 prior to 1.0.1.34, and XR300 prior to 1.0.3.50",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2021-29068"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-005326"
          },
          {
            "db": "VULMON",
            "id": "CVE-2021-29068"
          }
        ],
        "trust": 1.71
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2021-29068",
            "trust": 3.3
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-005326",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202103-1360",
            "trust": 0.6
          },
          {
            "db": "VULMON",
            "id": "CVE-2021-29068",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "VULMON",
            "id": "CVE-2021-29068"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-005326"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202103-1360"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-29068"
          }
        ]
      },
      "id": "VAR-202103-1271",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "VARIoT devices database",
            "id": null
          }
        ],
        "trust": 0.3117663121621622
      },
      "last_update_date": "2024-11-23T23:04:04.570000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Security\u00a0Advisory\u00a0for\u00a0Post-Authentication\u00a0Buffer\u00a0Overflow\u00a0on\u00a0Some\u00a0Routers,\u00a0Extenders,\u00a0and\u00a0WiFi\u00a0Systems\u00a0,\u00a0PSV-2020-0155",
            "trust": 0.8,
            "url": "https://kb.netgear.com/000063021/Security-Advisory-for-Post-Authentication-Buffer-Overflow-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2020-0155"
          },
          {
            "title": "Netgear NETGEAR Buffer error vulnerability fix",
            "trust": 0.6,
            "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=145681"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-005326"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202103-1360"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-120",
            "trust": 1.0
          },
          {
            "problemtype": "Classic buffer overflow (CWE-120) [NVD Evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-005326"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-29068"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.7,
            "url": "https://kb.netgear.com/000063021/security-advisory-for-post-authentication-buffer-overflow-on-some-routers-extenders-and-wifi-systems-psv-2020-0155"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2021-29068"
          },
          {
            "trust": 0.1,
            "url": "https://cwe.mitre.org/data/definitions/120.html"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov"
          }
        ],
        "sources": [
          {
            "db": "VULMON",
            "id": "CVE-2021-29068"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-005326"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202103-1360"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-29068"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "VULMON",
            "id": "CVE-2021-29068"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-005326"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202103-1360"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-29068"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2021-03-23T00:00:00",
            "db": "VULMON",
            "id": "CVE-2021-29068"
          },
          {
            "date": "2021-12-13T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2021-005326"
          },
          {
            "date": "2021-03-23T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202103-1360"
          },
          {
            "date": "2021-03-23T07:15:13.297000",
            "db": "NVD",
            "id": "CVE-2021-29068"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2021-03-27T00:00:00",
            "db": "VULMON",
            "id": "CVE-2021-29068"
          },
          {
            "date": "2021-12-13T01:53:00",
            "db": "JVNDB",
            "id": "JVNDB-2021-005326"
          },
          {
            "date": "2021-03-30T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202103-1360"
          },
          {
            "date": "2024-11-21T06:00:38.353000",
            "db": "NVD",
            "id": "CVE-2021-29068"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202103-1360"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "plural \u00a0NETGEAR\u00a0 Classic buffer overflow vulnerability in device",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-005326"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "buffer error",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202103-1360"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202112-2365

    Vulnerability from variot - Updated: 2024-11-23 23:03

    Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects RBK752 prior to 3.2.16.6, RBR750 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBK852 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, and RBS850 prior to 3.2.16.6

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2365",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "rbr850",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.16.6"
          },
          {
            "model": "rbk752",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.16.6"
          },
          {
            "model": "rbr750",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.16.6"
          },
          {
            "model": "rbk852",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.16.6"
          },
          {
            "model": "rbs850",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.16.6"
          },
          {
            "model": "rbs750",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.16.6"
          },
          {
            "model": "rbr750",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rbk752",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rbr850",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rbs750",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rbk852",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rbs850",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-016914"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45583"
          }
        ]
      },
      "cve": "CVE-2021-45583",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "ADJACENT_NETWORK",
                "authentication": "SINGLE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "PARTIAL",
                "baseScore": 5.2,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 5.1,
                "id": "CVE-2021-45583",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 1.9,
                "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 6.8,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 0.9,
                "id": "CVE-2021-45583",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT",
                "author": "cve@mitre.org",
                "availabilityImpact": "HIGH",
                "baseScore": 8.4,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 1.7,
                "id": "CVE-2021-45583",
                "impactScore": 6.0,
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Adjacent Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 6.8,
                "baseSeverity": "Medium",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "CVE-2021-45583",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "High",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2021-45583",
                "trust": 1.0,
                "value": "MEDIUM"
              },
              {
                "author": "cve@mitre.org",
                "id": "CVE-2021-45583",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "NVD",
                "id": "CVE-2021-45583",
                "trust": 0.8,
                "value": "Medium"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202112-2379",
                "trust": 0.6,
                "value": "MEDIUM"
              },
              {
                "author": "VULMON",
                "id": "CVE-2021-45583",
                "trust": 0.1,
                "value": "MEDIUM"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "VULMON",
            "id": "CVE-2021-45583"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-016914"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2379"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45583"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45583"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects RBK752 prior to 3.2.16.6, RBR750 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBK852 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, and RBS850 prior to 3.2.16.6",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2021-45583"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-016914"
          },
          {
            "db": "VULMON",
            "id": "CVE-2021-45583"
          }
        ],
        "trust": 1.71
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2021-45583",
            "trust": 3.3
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-016914",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2379",
            "trust": 0.6
          },
          {
            "db": "VULMON",
            "id": "CVE-2021-45583",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "VULMON",
            "id": "CVE-2021-45583"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-016914"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2379"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45583"
          }
        ]
      },
      "id": "VAR-202112-2365",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "VARIoT devices database",
            "id": null
          }
        ],
        "trust": 0.14124016
      },
      "last_update_date": "2024-11-23T23:03:57.898000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Security\u00a0Advisory\u00a0for\u00a0Post-Authentication\u00a0Command\u00a0Injection\u00a0on\u00a0Some\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0091",
            "trust": 0.8,
            "url": "https://kb.netgear.com/000064105/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0091"
          },
          {
            "title": "Netgear RBR750  and NETGEAR Fixes for command injection vulnerabilities",
            "trust": 0.6,
            "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=177091"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-016914"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2379"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-77",
            "trust": 1.0
          },
          {
            "problemtype": "Command injection (CWE-77) [NVD evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-016914"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45583"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.7,
            "url": "https://kb.netgear.com/000064105/security-advisory-for-post-authentication-command-injection-on-some-wifi-systems-psv-2020-0091"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45583"
          },
          {
            "trust": 0.1,
            "url": "https://cwe.mitre.org/data/definitions/77.html"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov"
          }
        ],
        "sources": [
          {
            "db": "VULMON",
            "id": "CVE-2021-45583"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-016914"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2379"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45583"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "VULMON",
            "id": "CVE-2021-45583"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-016914"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2379"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45583"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2021-12-26T00:00:00",
            "db": "VULMON",
            "id": "CVE-2021-45583"
          },
          {
            "date": "2022-12-27T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2021-016914"
          },
          {
            "date": "2021-12-26T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202112-2379"
          },
          {
            "date": "2021-12-26T01:15:16.933000",
            "db": "NVD",
            "id": "CVE-2021-45583"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2022-01-04T00:00:00",
            "db": "VULMON",
            "id": "CVE-2021-45583"
          },
          {
            "date": "2022-12-27T02:13:00",
            "db": "JVNDB",
            "id": "JVNDB-2021-016914"
          },
          {
            "date": "2022-01-05T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202112-2379"
          },
          {
            "date": "2024-11-21T06:32:35.230000",
            "db": "NVD",
            "id": "CVE-2021-45583"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote or local",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2379"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "plural \u00a0NETGEAR\u00a0 Command injection vulnerability in device",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-016914"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "command injection",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2379"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202112-2386

    Vulnerability from variot - Updated: 2024-11-23 23:03

    Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Netgear NETGEAR is a router from Netgear. A hardware device that connects two or more networks and acts as a gateway between the networks.

    A security vulnerability exists in some NETGEAR devices. Attackers can exploit this vulnerability to perform command injection. This affects RBK752 prior to 3.2.16.6, RBR750 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBK852 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, and RBS850 prior to 3.2.16.6

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2386",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "rbr850",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.16.6"
          },
          {
            "model": "rbk752",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.16.6"
          },
          {
            "model": "rbr750",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.16.6"
          },
          {
            "model": "rbk852",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.16.6"
          },
          {
            "model": "rbs850",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.16.6"
          },
          {
            "model": "rbs750",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.16.6"
          },
          {
            "model": "rbr750",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rbk752",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rbr850",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rbs750",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rbk852",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rbs850",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rbr750",
            "scope": null,
            "trust": 0.6,
            "vendor": "netgear",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2022-06686"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-016905"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45562"
          }
        ]
      },
      "cve": "CVE-2021-45562",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "ADJACENT_NETWORK",
                "authentication": "SINGLE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "PARTIAL",
                "baseScore": 5.2,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 5.1,
                "id": "CVE-2021-45562",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 1.9,
                "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "ADJACENT_NETWORK",
                "authentication": "SINGLE",
                "author": "CNVD",
                "availabilityImpact": "PARTIAL",
                "baseScore": 5.2,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 5.1,
                "id": "CNVD-2022-06686",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 0.6,
                "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 6.8,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 0.9,
                "id": "CVE-2021-45562",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT",
                "author": "cve@mitre.org",
                "availabilityImpact": "HIGH",
                "baseScore": 8.4,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 1.7,
                "id": "CVE-2021-45562",
                "impactScore": 6.0,
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Adjacent Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 6.8,
                "baseSeverity": "Medium",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "CVE-2021-45562",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "High",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2021-45562",
                "trust": 1.0,
                "value": "MEDIUM"
              },
              {
                "author": "cve@mitre.org",
                "id": "CVE-2021-45562",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "NVD",
                "id": "CVE-2021-45562",
                "trust": 0.8,
                "value": "Medium"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2022-06686",
                "trust": 0.6,
                "value": "MEDIUM"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202112-2293",
                "trust": 0.6,
                "value": "MEDIUM"
              },
              {
                "author": "VULMON",
                "id": "CVE-2021-45562",
                "trust": 0.1,
                "value": "MEDIUM"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2022-06686"
          },
          {
            "db": "VULMON",
            "id": "CVE-2021-45562"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-016905"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2293"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45562"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45562"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Netgear NETGEAR is a router from Netgear. A hardware device that connects two or more networks and acts as a gateway between the networks. \n\r\n\r\nA security vulnerability exists in some NETGEAR devices. Attackers can exploit this vulnerability to perform command injection. This affects RBK752 prior to 3.2.16.6, RBR750 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBK852 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, and RBS850 prior to 3.2.16.6",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2021-45562"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-016905"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2022-06686"
          },
          {
            "db": "VULMON",
            "id": "CVE-2021-45562"
          }
        ],
        "trust": 2.25
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2021-45562",
            "trust": 3.9
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-016905",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2022-06686",
            "trust": 0.6
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2293",
            "trust": 0.6
          },
          {
            "db": "VULMON",
            "id": "CVE-2021-45562",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2022-06686"
          },
          {
            "db": "VULMON",
            "id": "CVE-2021-45562"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-016905"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2293"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45562"
          }
        ]
      },
      "id": "VAR-202112-2386",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2022-06686"
          }
        ],
        "trust": 0.74124016
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2022-06686"
          }
        ]
      },
      "last_update_date": "2024-11-23T23:03:57.868000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Security\u00a0Advisory\u00a0for\u00a0Post-Authentication\u00a0Command\u00a0Injection\u00a0on\u00a0Some\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0060",
            "trust": 0.8,
            "url": "https://kb.netgear.com/000064082/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0060"
          },
          {
            "title": "Patch for NETGEAR RBR750 Command Injection Vulnerability",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/315986"
          },
          {
            "title": "Netgear NETGEAR Fixes for command injection vulnerabilities",
            "trust": 0.6,
            "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=177055"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2022-06686"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-016905"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2293"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-77",
            "trust": 1.0
          },
          {
            "problemtype": "Command injection (CWE-77) [NVD evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-016905"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45562"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.0,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45562"
          },
          {
            "trust": 1.7,
            "url": "https://kb.netgear.com/000064082/security-advisory-for-post-authentication-command-injection-on-some-wifi-systems-psv-2020-0060"
          },
          {
            "trust": 0.1,
            "url": "https://cwe.mitre.org/data/definitions/77.html"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2022-06686"
          },
          {
            "db": "VULMON",
            "id": "CVE-2021-45562"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-016905"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2293"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45562"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2022-06686"
          },
          {
            "db": "VULMON",
            "id": "CVE-2021-45562"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-016905"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2293"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45562"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2022-01-25T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2022-06686"
          },
          {
            "date": "2021-12-26T00:00:00",
            "db": "VULMON",
            "id": "CVE-2021-45562"
          },
          {
            "date": "2022-12-26T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2021-016905"
          },
          {
            "date": "2021-12-25T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202112-2293"
          },
          {
            "date": "2021-12-26T01:15:15.940000",
            "db": "NVD",
            "id": "CVE-2021-45562"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2022-01-25T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2022-06686"
          },
          {
            "date": "2022-01-04T00:00:00",
            "db": "VULMON",
            "id": "CVE-2021-45562"
          },
          {
            "date": "2022-12-26T08:53:00",
            "db": "JVNDB",
            "id": "JVNDB-2021-016905"
          },
          {
            "date": "2022-01-05T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202112-2293"
          },
          {
            "date": "2024-11-21T06:32:31.677000",
            "db": "NVD",
            "id": "CVE-2021-45562"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote or local",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2293"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "plural \u00a0NETGEAR\u00a0 Command injection vulnerability in device",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-016905"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "command injection",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2293"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202112-2407

    Vulnerability from variot - Updated: 2024-11-23 23:03

    Certain NETGEAR devices are affected by command injection by an authenticated user. This affects R7900 before 1.0.4.38, R7900P before 1.4.2.84, R8000 before 1.0.4.68, R8000P before 1.4.2.84, RAX200 before 1.0.3.106, MR60 before 1.0.6.110, RAX45 before 1.0.2.72, RAX80 before 1.0.3.106, MS60 before 1.0.6.110, RAX50 before 1.0.2.72, RAX75 before 1.0.3.106, RBR750 before 3.2.16.6, RBR850 before 3.2.16.6, RBS750 before 3.2.16.6, RBS850 before 3.2.16.6, RBK752 before 3.2.16.6, and RBK852 before 3.2.16.6. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects R7900 prior to 1.0.4.38, R7900P prior to 1.4.2.84, R8000 prior to 1.0.4.68, R8000P prior to 1.4.2.84, RAX200 prior to 1.0.3.106, MR60 prior to 1.0.6.110, RAX45 prior to 1.0.2.72, RAX80 prior to 1.0.3.106, MS60 prior to 1.0.6.110, RAX50 prior to 1.0.2.72, RAX75 prior to 1.0.3.106, RBR750 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBS850 prior to 3.2.16.6, RBK752 prior to 3.2.16.6, and RBK852 prior to 3.2.16.6

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2407",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "rax45",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.2.72"
          },
          {
            "model": "rbk752",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.16.6"
          },
          {
            "model": "r7900",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.4.38"
          },
          {
            "model": "rax75",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.3.106"
          },
          {
            "model": "rbs750",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.16.6"
          },
          {
            "model": "r8000",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.4.68"
          },
          {
            "model": "r8000p",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.4.2.84"
          },
          {
            "model": "rbr850",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.16.6"
          },
          {
            "model": "mr60",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.6.110"
          },
          {
            "model": "rbr750",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.16.6"
          },
          {
            "model": "rbk852",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.16.6"
          },
          {
            "model": "rax50",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.2.72"
          },
          {
            "model": "rax200",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.3.106"
          },
          {
            "model": "r7900p",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.4.2.84"
          },
          {
            "model": "rbs850",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.16.6"
          },
          {
            "model": "ms60",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.6.110"
          },
          {
            "model": "rax80",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.3.106"
          },
          {
            "model": "rax45",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "ms60",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rax75",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "mr60",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rbs750",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rax80",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rbr750",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rax50",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rbr850",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rax200",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-017288"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45541"
          }
        ]
      },
      "cve": "CVE-2021-45541",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "PARTIAL",
                "baseScore": 6.5,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 8.0,
                "id": "CVE-2021-45541",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 1.9,
                "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.8,
                "id": "CVE-2021-45541",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT",
                "author": "cve@mitre.org",
                "availabilityImpact": "HIGH",
                "baseScore": 8.4,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 1.7,
                "id": "CVE-2021-45541",
                "impactScore": 6.0,
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 8.8,
                "baseSeverity": "High",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "CVE-2021-45541",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "Low",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2021-45541",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "cve@mitre.org",
                "id": "CVE-2021-45541",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "NVD",
                "id": "CVE-2021-45541",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202112-2359",
                "trust": 0.6,
                "value": "HIGH"
              },
              {
                "author": "VULMON",
                "id": "CVE-2021-45541",
                "trust": 0.1,
                "value": "MEDIUM"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "VULMON",
            "id": "CVE-2021-45541"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-017288"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2359"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45541"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45541"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects R7900 before 1.0.4.38, R7900P before 1.4.2.84, R8000 before 1.0.4.68, R8000P before 1.4.2.84, RAX200 before 1.0.3.106, MR60 before 1.0.6.110, RAX45 before 1.0.2.72, RAX80 before 1.0.3.106, MS60 before 1.0.6.110, RAX50 before 1.0.2.72, RAX75 before 1.0.3.106, RBR750 before 3.2.16.6, RBR850 before 3.2.16.6, RBS750 before 3.2.16.6, RBS850 before 3.2.16.6, RBK752 before 3.2.16.6, and RBK852 before 3.2.16.6. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects R7900 prior to 1.0.4.38, R7900P prior to 1.4.2.84, R8000 prior to 1.0.4.68, R8000P prior to 1.4.2.84, RAX200 prior to 1.0.3.106, MR60 prior to 1.0.6.110, RAX45 prior to 1.0.2.72, RAX80 prior to 1.0.3.106, MS60 prior to 1.0.6.110, RAX50 prior to 1.0.2.72, RAX75 prior to 1.0.3.106, RBR750 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBS850 prior to 3.2.16.6, RBK752 prior to 3.2.16.6, and RBK852 prior to 3.2.16.6",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2021-45541"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-017288"
          },
          {
            "db": "VULMON",
            "id": "CVE-2021-45541"
          }
        ],
        "trust": 1.71
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2021-45541",
            "trust": 3.3
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-017288",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2359",
            "trust": 0.6
          },
          {
            "db": "VULMON",
            "id": "CVE-2021-45541",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "VULMON",
            "id": "CVE-2021-45541"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-017288"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2359"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45541"
          }
        ]
      },
      "id": "VAR-202112-2407",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "VARIoT devices database",
            "id": null
          }
        ],
        "trust": 0.282927312
      },
      "last_update_date": "2024-11-23T23:03:57.843000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Security\u00a0Advisory\u00a0for\u00a0Post-Authentication\u00a0Command\u00a0Injection\u00a0on\u00a0Some\u00a0Routers\u00a0and\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0246",
            "trust": 0.8,
            "url": "https://kb.netgear.com/000064479/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2020-0246"
          },
          {
            "title": "Netgear RBR750  and NETGEAR Security vulnerabilities",
            "trust": 0.6,
            "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=176372"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-017288"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2359"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-77",
            "trust": 1.0
          },
          {
            "problemtype": "Command injection (CWE-77) [NVD evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-017288"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45541"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.7,
            "url": "https://kb.netgear.com/000064479/security-advisory-for-post-authentication-command-injection-on-some-routers-and-wifi-systems-psv-2020-0246"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45541"
          },
          {
            "trust": 0.1,
            "url": "https://cwe.mitre.org/data/definitions/77.html"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov"
          }
        ],
        "sources": [
          {
            "db": "VULMON",
            "id": "CVE-2021-45541"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-017288"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2359"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45541"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "VULMON",
            "id": "CVE-2021-45541"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-017288"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2359"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45541"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2021-12-26T00:00:00",
            "db": "VULMON",
            "id": "CVE-2021-45541"
          },
          {
            "date": "2023-01-13T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2021-017288"
          },
          {
            "date": "2021-12-26T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202112-2359"
          },
          {
            "date": "2021-12-26T01:15:14.937000",
            "db": "NVD",
            "id": "CVE-2021-45541"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2022-01-07T00:00:00",
            "db": "VULMON",
            "id": "CVE-2021-45541"
          },
          {
            "date": "2023-01-13T05:03:00",
            "db": "JVNDB",
            "id": "JVNDB-2021-017288"
          },
          {
            "date": "2022-01-10T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202112-2359"
          },
          {
            "date": "2024-11-21T06:32:27.987000",
            "db": "NVD",
            "id": "CVE-2021-45541"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2359"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "plural \u00a0NETGEAR\u00a0 Command injection vulnerability in device",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-017288"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "command injection",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2359"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202006-0931

    Vulnerability from variot - Updated: 2024-11-23 23:01

    Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, RBS850 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, and RBS840 before 3.2.15.25. plural NETGEAR A device contains an injection vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. NETGEAR RBK752, etc. are all home WiFi systems of NETGEAR.

    Injection vulnerabilities exist in many NETGEAR products. The vulnerability stems from the fact that the network system or product lacks the correct verification of the user input data during the operation process of the user inputting the construction command, data structure or record, and the special elements are not filtered or correctly filtered, resulting in the analysis or analysis of the system or product. The explanation is wrong. No detailed vulnerability details are currently provided

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202006-0931",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "rbk752",
            "scope": "lt",
            "trust": 1.6,
            "vendor": "netgear",
            "version": "3.2.15.25"
          },
          {
            "model": "rbr750",
            "scope": "lt",
            "trust": 1.6,
            "vendor": "netgear",
            "version": "3.2.15.25"
          },
          {
            "model": "rbs750",
            "scope": "lt",
            "trust": 1.6,
            "vendor": "netgear",
            "version": "3.2.15.25"
          },
          {
            "model": "rbk753",
            "scope": "lt",
            "trust": 1.6,
            "vendor": "netgear",
            "version": "3.2.15.25"
          },
          {
            "model": "rbk753s",
            "scope": "lt",
            "trust": 1.6,
            "vendor": "netgear",
            "version": "3.2.15.25"
          },
          {
            "model": "rbk842",
            "scope": "lt",
            "trust": 1.6,
            "vendor": "netgear",
            "version": "3.2.15.25"
          },
          {
            "model": "rbr840",
            "scope": "lt",
            "trust": 1.6,
            "vendor": "netgear",
            "version": "3.2.15.25"
          },
          {
            "model": "rbs840",
            "scope": "lt",
            "trust": 1.6,
            "vendor": "netgear",
            "version": "3.2.15.25"
          },
          {
            "model": "rbk852",
            "scope": "lt",
            "trust": 1.6,
            "vendor": "netgear",
            "version": "3.2.15.25"
          },
          {
            "model": "rbk853",
            "scope": "lt",
            "trust": 1.6,
            "vendor": "netgear",
            "version": "3.2.15.25"
          },
          {
            "model": "rbr850",
            "scope": "lt",
            "trust": 1.6,
            "vendor": "netgear",
            "version": "3.2.15.25"
          },
          {
            "model": "rbs850",
            "scope": "lt",
            "trust": 1.6,
            "vendor": "netgear",
            "version": "3.2.15.25"
          },
          {
            "model": "rbk752",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "netgear",
            "version": "3.2.15.25"
          },
          {
            "model": "rbk753",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "netgear",
            "version": "3.2.15.25"
          },
          {
            "model": "rbk753s",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "netgear",
            "version": "3.2.15.25"
          },
          {
            "model": "rbk842",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "netgear",
            "version": "3.2.15.25"
          },
          {
            "model": "rbk852",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "netgear",
            "version": "3.2.15.25"
          },
          {
            "model": "rbk853",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "netgear",
            "version": "3.2.15.25"
          },
          {
            "model": "rbr750",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "netgear",
            "version": "3.2.15.25"
          },
          {
            "model": "rbr850",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "netgear",
            "version": "3.2.15.25"
          },
          {
            "model": "rbs750",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "netgear",
            "version": "3.2.15.25"
          },
          {
            "model": "rbs850",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "netgear",
            "version": "3.2.15.25"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-44779"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-006745"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-14434"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "cpe_match": [
                  {
                    "cpe22Uri": "cpe:/o:netgear:rbk752_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:netgear:rbk753_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:netgear:rbk753s_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:netgear:rbk842_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:netgear:rbk852_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:netgear:rbk853_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:netgear:rbr750_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:netgear:rbr850_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:netgear:rbs750_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:netgear:rbs850_firmware",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-006745"
          }
        ]
      },
      "cve": "CVE-2020-14434",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "ADJACENT_NETWORK",
                "authentication": "SINGLE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "COMPLETE",
                "baseScore": 7.7,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 5.1,
                "id": "CVE-2020-14434",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 1.0,
                "vectorString": "AV:A/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "acInsufInfo": null,
                "accessComplexity": "Low",
                "accessVector": "Adjacent Network",
                "authentication": "Single",
                "author": "NVD",
                "availabilityImpact": "Complete",
                "baseScore": 7.7,
                "confidentialityImpact": "Complete",
                "exploitabilityScore": null,
                "id": "JVNDB-2020-006745",
                "impactScore": null,
                "integrityImpact": "Complete",
                "obtainAllPrivilege": null,
                "obtainOtherPrivilege": null,
                "obtainUserPrivilege": null,
                "severity": "High",
                "trust": 0.8,
                "userInteractionRequired": null,
                "vectorString": "AV:A/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "ADJACENT_NETWORK",
                "authentication": "SINGLE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 7.7,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 5.1,
                "id": "CNVD-2021-44779",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:A/AC:L/Au:S/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 6.8,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 0.9,
                "id": "CVE-2020-14434",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT",
                "author": "cve@mitre.org",
                "availabilityImpact": "HIGH",
                "baseScore": 8.4,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 1.7,
                "id": "CVE-2020-14434",
                "impactScore": 6.0,
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.0"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Adjacent Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 6.8,
                "baseSeverity": "Medium",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "JVNDB-2020-006745",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "High",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2020-14434",
                "trust": 1.0,
                "value": "MEDIUM"
              },
              {
                "author": "cve@mitre.org",
                "id": "CVE-2020-14434",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "NVD",
                "id": "JVNDB-2020-006745",
                "trust": 0.8,
                "value": "Medium"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2021-44779",
                "trust": 0.6,
                "value": "HIGH"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202006-1250",
                "trust": 0.6,
                "value": "MEDIUM"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-44779"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-006745"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202006-1250"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-14434"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-14434"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, RBS850 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, and RBS840 before 3.2.15.25. plural NETGEAR A device contains an injection vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. NETGEAR RBK752, etc. are all home WiFi systems of NETGEAR. \n\r\n\r\nInjection vulnerabilities exist in many NETGEAR products. The vulnerability stems from the fact that the network system or product lacks the correct verification of the user input data during the operation process of the user inputting the construction command, data structure or record, and the special elements are not filtered or correctly filtered, resulting in the analysis or analysis of the system or product. The explanation is wrong. No detailed vulnerability details are currently provided",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2020-14434"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-006745"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2021-44779"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2020-14434",
            "trust": 3.0
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-006745",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2021-44779",
            "trust": 0.6
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202006-1250",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-44779"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-006745"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202006-1250"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-14434"
          }
        ]
      },
      "id": "VAR-202006-0931",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-44779"
          }
        ],
        "trust": 1.0097272085714286
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-44779"
          }
        ]
      },
      "last_update_date": "2024-11-23T23:01:21.848000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Security Advisory for Post-Authentication Command Injection on Some WiFi Systems, PSV-2020-0040",
            "trust": 0.8,
            "url": "https://kb.netgear.com/000061934/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0040"
          },
          {
            "title": "Patch for Command injection vulnerabilities in multiple NETGEAR products (CNVD-2021-44779)",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/275091"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-44779"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-006745"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-77",
            "trust": 1.0
          },
          {
            "problemtype": "CWE-74",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-006745"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-14434"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.0,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2020-14434"
          },
          {
            "trust": 1.6,
            "url": "https://kb.netgear.com/000061934/security-advisory-for-post-authentication-command-injection-on-some-wifi-systems-psv-2020-0040"
          },
          {
            "trust": 0.8,
            "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-14434"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-44779"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-006745"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202006-1250"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-14434"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-44779"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-006745"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202006-1250"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-14434"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2020-06-24T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2021-44779"
          },
          {
            "date": "2020-07-16T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2020-006745"
          },
          {
            "date": "2020-06-18T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202006-1250"
          },
          {
            "date": "2020-06-18T17:15:12.547000",
            "db": "NVD",
            "id": "CVE-2020-14434"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2021-06-24T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2021-44779"
          },
          {
            "date": "2020-07-16T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2020-006745"
          },
          {
            "date": "2020-06-23T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202006-1250"
          },
          {
            "date": "2024-11-21T05:03:15.850000",
            "db": "NVD",
            "id": "CVE-2020-14434"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote or local",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202006-1250"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "plural  NETGEAR Injection vulnerabilities in devices",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-006745"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "injection",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202006-1250"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202010-0565

    Vulnerability from variot - Updated: 2024-11-23 23:01

    Certain NETGEAR devices are affected by disclosure of sensitive information. This affects CBR40 before 2.5.0.10, RBK752 before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.10.11, RBR850 before 3.2.10.11, and RBS850 before 3.2.10.11

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202010-0565",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "rbk852",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.10.11"
          },
          {
            "model": "rbr750",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.15.25"
          },
          {
            "model": "cbr40",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "2.5.0.10"
          },
          {
            "model": "rbk752",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.15.25"
          },
          {
            "model": "rbs850",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.10.11"
          },
          {
            "model": "rbs750",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.15.25"
          },
          {
            "model": "rbr850",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.10.11"
          },
          {
            "model": "cbr40",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rbk752",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rbk852",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rbr750",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rbr850",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rbs750",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rbs850",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-012224"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-26899"
          }
        ]
      },
      "cve": "CVE-2020-26899",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "ADJACENT_NETWORK",
                "authentication": "NONE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "NONE",
                "baseScore": 3.3,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 6.5,
                "id": "CVE-2020-26899",
                "impactScore": 2.9,
                "integrityImpact": "NONE",
                "severity": "LOW",
                "trust": 1.8,
                "vectorString": "AV:A/AC:L/Au:N/C:P/I:N/A:N",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT",
                "author": "nvd@nist.gov",
                "availabilityImpact": "NONE",
                "baseScore": 6.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.8,
                "id": "CVE-2020-26899",
                "impactScore": 3.6,
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.1"
              },
              {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT",
                "author": "cve@mitre.org",
                "availabilityImpact": "LOW",
                "baseScore": 9.6,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.8,
                "id": "CVE-2020-26899",
                "impactScore": 6.0,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:L",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Adjacent Network",
                "author": "NVD",
                "availabilityImpact": "None",
                "baseScore": 6.5,
                "baseSeverity": "Medium",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "CVE-2020-26899",
                "impactScore": null,
                "integrityImpact": "None",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2020-26899",
                "trust": 1.0,
                "value": "MEDIUM"
              },
              {
                "author": "cve@mitre.org",
                "id": "CVE-2020-26899",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "NVD",
                "id": "CVE-2020-26899",
                "trust": 0.8,
                "value": "Medium"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202010-329",
                "trust": 0.6,
                "value": "MEDIUM"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-012224"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202010-329"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-26899"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-26899"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Certain NETGEAR devices are affected by disclosure of sensitive information. This affects CBR40 before 2.5.0.10, RBK752 before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.10.11, RBR850 before 3.2.10.11, and RBS850 before 3.2.10.11",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2020-26899"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-012224"
          }
        ],
        "trust": 1.62
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2020-26899",
            "trust": 2.4
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-012224",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202010-329",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-012224"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202010-329"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-26899"
          }
        ]
      },
      "id": "VAR-202010-0565",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "VARIoT devices database",
            "id": null
          }
        ],
        "trust": 0.14124016
      },
      "last_update_date": "2024-11-23T23:01:13.635000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Security\u00a0Advisory\u00a0for\u00a0Sensitive\u00a0Information\u00a0Disclosure\u00a0on\u00a0Some\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0030",
            "trust": 0.8,
            "url": "https://kb.netgear.com/000062355/Security-Advisory-for-Sensitive-Information-Disclosure-on-Some-WiFi-Systems-PSV-2020-0030"
          },
          {
            "title": "Multiple  NETGEAR Repair measures for device information disclosure vulnerabilities",
            "trust": 0.6,
            "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=131118"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-012224"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202010-329"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "NVD-CWE-noinfo",
            "trust": 1.0
          },
          {
            "problemtype": "information leak (CWE-200) [NVD Evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-012224"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-26899"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.6,
            "url": "https://kb.netgear.com/000062355/security-advisory-for-sensitive-information-disclosure-on-some-wifi-systems-psv-2020-0030"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2020-26899"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-012224"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202010-329"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-26899"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-012224"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202010-329"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-26899"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2021-04-27T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2020-012224"
          },
          {
            "date": "2020-10-09T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202010-329"
          },
          {
            "date": "2020-10-09T07:15:13.870000",
            "db": "NVD",
            "id": "CVE-2020-26899"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2021-04-27T05:46:00",
            "db": "JVNDB",
            "id": "JVNDB-2020-012224"
          },
          {
            "date": "2020-10-21T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202010-329"
          },
          {
            "date": "2024-11-21T05:20:26.647000",
            "db": "NVD",
            "id": "CVE-2020-26899"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote or local",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202010-329"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "plural \u00a0NETGEAR\u00a0 Information leakage vulnerabilities in devices",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-012224"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "information disclosure",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202010-329"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202012-1194

    Vulnerability from variot - Updated: 2024-11-23 23:01

    Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects AC2100 before 1.2.0.72, AC2400 before 1.2.0.72, AC2600 before 1.2.0.72, CBK40 before 2.5.0.10, CBR40 before 2.5.0.10, D7800 before 1.0.1.58, EAX20 before 1.0.0.36, EAX80 before 1.0.1.62, EX7500 before 1.0.0.68, MK62 before 1.0.5.102, MR60 before 1.0.5.102, MS60 before 1.0.5.102, R6120 before 1.0.0.70, R6220 before 1.1.0.100, R6230 before 1.1.0.100, R6260 before 1.1.0.76, R6330 before 1.1.0.76, R6350 before 1.1.0.76, R6400 before 1.0.1.62, R6400v2 before 1.0.4.98, R6700 before 1.0.2.16, R6700v2 before 1.2.0.72, R6700v3 before 1.0.4.98, R6800 before 1.2.0.72, R6850 before 1.1.0.76, R6900P before 1.3.2.124, R6900 before 1.0.2.16, R6900v2 before 1.2.0.72, R7000 before 1.0.11.106, R7000P before 1.3.2.124, R7200 before 1.2.0.72, R7350 before 1.2.0.72, R7400 before 1.2.0.72, R7450 before 1.2.0.72, R7800 before 1.0.2.74, R7850 before 1.0.5.60, R7900 before 1.0.4.26, R7900P before 1.4.1.62, R7960P before 1.4.1.62, R8000 before 1.0.4.58, R8000P before 1.4.1.62, R8900 before 1.0.5.24, R9000 before 1.0.5.24, RAX120 before 1.0.1.136, RAX15 before 1.0.1.64, RAX20 before 1.0.1.64, RAX200 before 1.0.2.102, RAX45 before 1.0.2.64, RAX50 before 1.0.2.64, RAX75 before 1.0.3.102, RAX80 before 1.0.3.102, RBK12 before 2.6.1.44, RBR10 before 2.6.1.44, RBS10 before 2.6.1.44, RBK20 before 2.6.1.38, RBR20 before 2.6.1.36, RBS20 before 2.6.1.38, RBK40 before 2.6.1.38, RBR40 before 2.6.1.36, RBS40 before 2.6.1.38, RBK50 before 2.6.1.40, RBR50 before 2.6.1.40, RBS50 before 2.6.1.40, RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK842 before 3.2.16.6, RBR840 before 3.2.16.6, RBS840 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, RBS850 before 3.2.16.6, RS400 before 1.5.0.48, XR300 before 1.0.3.50, XR450 before 2.3.2.66, XR500 before 2.3.2.66, and XR700 before 1.0.1.34. plural NETGEAR A classic buffer overflow vulnerability exists in the device.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202012-1194",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "ms60",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.5.102"
          },
          {
            "model": "r7400",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.2.0.72"
          },
          {
            "model": "rax200",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.2.102"
          },
          {
            "model": "rbr50",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "2.6.1.40"
          },
          {
            "model": "r6900",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.2.16"
          },
          {
            "model": "r7350",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.2.0.72"
          },
          {
            "model": "mk62",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.5.102"
          },
          {
            "model": "rbs850",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.16.6"
          },
          {
            "model": "rbk50",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "2.6.1.40"
          },
          {
            "model": "rbk12",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "2.6.1.44"
          },
          {
            "model": "rbs10",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "2.6.1.44"
          },
          {
            "model": "cbk40",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "2.5.0.10"
          },
          {
            "model": "rax120",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.1.136"
          },
          {
            "model": "rbr40",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "2.6.1.36"
          },
          {
            "model": "rbs750",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.16.6"
          },
          {
            "model": "rax75",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.3.102"
          },
          {
            "model": "r6230",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.1.0.100"
          },
          {
            "model": "r9000",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.5.24"
          },
          {
            "model": "eax80",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.1.62"
          },
          {
            "model": "r7800",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.2.74"
          },
          {
            "model": "ac2100",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.2.0.72"
          },
          {
            "model": "r7900",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.4.26"
          },
          {
            "model": "xr300",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.3.50"
          },
          {
            "model": "d7800",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.1.58"
          },
          {
            "model": "rax50",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.2.64"
          },
          {
            "model": "r6260",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.1.0.76"
          },
          {
            "model": "r8900",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.5.24"
          },
          {
            "model": "rbk20",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "2.6.1.38"
          },
          {
            "model": "r6120",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.0.70"
          },
          {
            "model": "rbr20",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "2.6.1.36"
          },
          {
            "model": "xr700",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.1.34"
          },
          {
            "model": "ex7500",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.0.68"
          },
          {
            "model": "xr500",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "2.3.2.66"
          },
          {
            "model": "rbr840",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.16.6"
          },
          {
            "model": "r7960p",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.4.1.62"
          },
          {
            "model": "rax20",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.1.64"
          },
          {
            "model": "rbr850",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.16.6"
          },
          {
            "model": "rbs20",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "2.6.1.38"
          },
          {
            "model": "r6700v3",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.4.98"
          },
          {
            "model": "ac2600",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.2.0.72"
          },
          {
            "model": "ac2400",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.2.0.72"
          },
          {
            "model": "cbr40",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "2.5.0.10"
          },
          {
            "model": "rbs50",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "2.6.1.40"
          },
          {
            "model": "r6330",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.1.0.76"
          },
          {
            "model": "rbk852",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.16.6"
          },
          {
            "model": "r8000p",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.4.1.62"
          },
          {
            "model": "r6800",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.2.0.72"
          },
          {
            "model": "r6900p",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.3.2.124"
          },
          {
            "model": "xr450",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "2.3.2.66"
          },
          {
            "model": "rs400",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.5.0.48"
          },
          {
            "model": "r6900v2",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.2.0.72"
          },
          {
            "model": "r6350",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.1.0.76"
          },
          {
            "model": "r7000",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.11.106"
          },
          {
            "model": "r6400v2",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.4.98"
          },
          {
            "model": "r7850",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.5.60"
          },
          {
            "model": "r6400",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.1.62"
          },
          {
            "model": "mr60",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.5.102"
          },
          {
            "model": "eax20",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.0.36"
          },
          {
            "model": "rbk842",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.16.6"
          },
          {
            "model": "rbr750",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.16.6"
          },
          {
            "model": "r7200",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.2.0.72"
          },
          {
            "model": "r6700v2",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.2.0.72"
          },
          {
            "model": "r8000",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.4.58"
          },
          {
            "model": "rax80",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.3.102"
          },
          {
            "model": "r6700",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.2.16"
          },
          {
            "model": "rax45",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.2.64"
          },
          {
            "model": "rbk40",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "2.6.1.38"
          },
          {
            "model": "rbs40",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "2.6.1.38"
          },
          {
            "model": "rax15",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.1.64"
          },
          {
            "model": "rbk752",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.16.6"
          },
          {
            "model": "r6220",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.1.0.100"
          },
          {
            "model": "r6850",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.1.0.76"
          },
          {
            "model": "r7450",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.2.0.72"
          },
          {
            "model": "rbs840",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.16.6"
          },
          {
            "model": "r7900p",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.4.1.62"
          },
          {
            "model": "r7000p",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.3.2.124"
          },
          {
            "model": "rbr10",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "2.6.1.44"
          },
          {
            "model": "ac2400",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "mk62",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "cbk40",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "d7800",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "ex7500",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "eax20",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "ac2600",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "eax80",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "ac2100",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "cbr40",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-015039"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-35795"
          }
        ]
      },
      "cve": "CVE-2020-35795",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "PARTIAL",
                "baseScore": 7.5,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 10.0,
                "id": "CVE-2020-35795",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "HIGH",
                "trust": 1.8,
                "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "id": "CVE-2020-35795",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 2.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "OTHER",
                "availabilityImpact": "High",
                "baseScore": 9.8,
                "baseSeverity": "Critical",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "JVNDB-2020-015039",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2020-35795",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "cve@mitre.org",
                "id": "CVE-2020-35795",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "NVD",
                "id": "CVE-2020-35795",
                "trust": 0.8,
                "value": "Critical"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202012-1750",
                "trust": 0.6,
                "value": "CRITICAL"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-015039"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202012-1750"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-35795"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-35795"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Certain NETGEAR devices are affected by a buffer overflow by an unauthenticated attacker. This affects AC2100 before 1.2.0.72, AC2400 before 1.2.0.72, AC2600 before 1.2.0.72, CBK40 before 2.5.0.10, CBR40 before 2.5.0.10, D7800 before 1.0.1.58, EAX20 before 1.0.0.36, EAX80 before 1.0.1.62, EX7500 before 1.0.0.68, MK62 before 1.0.5.102, MR60 before 1.0.5.102, MS60 before 1.0.5.102, R6120 before 1.0.0.70, R6220 before 1.1.0.100, R6230 before 1.1.0.100, R6260 before 1.1.0.76, R6330 before 1.1.0.76, R6350 before 1.1.0.76, R6400 before 1.0.1.62, R6400v2 before 1.0.4.98, R6700 before 1.0.2.16, R6700v2 before 1.2.0.72, R6700v3 before 1.0.4.98, R6800 before 1.2.0.72, R6850 before 1.1.0.76, R6900P before 1.3.2.124, R6900 before 1.0.2.16, R6900v2 before 1.2.0.72, R7000 before 1.0.11.106, R7000P before 1.3.2.124, R7200 before 1.2.0.72, R7350 before 1.2.0.72, R7400 before 1.2.0.72, R7450 before 1.2.0.72, R7800 before 1.0.2.74, R7850 before 1.0.5.60, R7900 before 1.0.4.26, R7900P before 1.4.1.62, R7960P before 1.4.1.62, R8000 before 1.0.4.58, R8000P before 1.4.1.62, R8900 before 1.0.5.24, R9000 before 1.0.5.24, RAX120 before 1.0.1.136, RAX15 before 1.0.1.64, RAX20 before 1.0.1.64, RAX200 before 1.0.2.102, RAX45 before 1.0.2.64, RAX50 before 1.0.2.64, RAX75 before 1.0.3.102, RAX80 before 1.0.3.102, RBK12 before 2.6.1.44, RBR10 before 2.6.1.44, RBS10 before 2.6.1.44, RBK20 before 2.6.1.38, RBR20 before 2.6.1.36, RBS20 before 2.6.1.38, RBK40 before 2.6.1.38, RBR40 before 2.6.1.36, RBS40 before 2.6.1.38, RBK50 before 2.6.1.40, RBR50 before 2.6.1.40, RBS50 before 2.6.1.40, RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK842 before 3.2.16.6, RBR840 before 3.2.16.6, RBS840 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, RBS850 before 3.2.16.6, RS400 before 1.5.0.48, XR300 before 1.0.3.50, XR450 before 2.3.2.66, XR500 before 2.3.2.66, and XR700 before 1.0.1.34. plural NETGEAR A classic buffer overflow vulnerability exists in the device.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2020-35795"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-015039"
          }
        ],
        "trust": 1.62
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2020-35795",
            "trust": 2.4
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-015039",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202012-1750",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-015039"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202012-1750"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-35795"
          }
        ]
      },
      "id": "VAR-202012-1194",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "VARIoT devices database",
            "id": null
          }
        ],
        "trust": 0.3302461448717948
      },
      "last_update_date": "2024-11-23T23:01:10.862000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Security\u00a0Advisory\u00a0for\u00a0Pre-Authentication\u00a0Buffer\u00a0Overflow\u00a0on\u00a0Some\u00a0Routers,\u00a0Range\u00a0Extenders,\u00a0and\u00a0Orbi\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0154",
            "trust": 0.8,
            "url": "https://kb.netgear.com/000062735/Security-Advisory-for-Pre-Authentication-Buffer-Overflow-on-Some-Routers-Range-Extenders-and-Orbi-WiFi-Systems-PSV-2020-0154"
          },
          {
            "title": "Certain NETGEAR devices Security vulnerabilities",
            "trust": 0.6,
            "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=138129"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-015039"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202012-1750"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-120",
            "trust": 1.0
          },
          {
            "problemtype": "Classic buffer overflow (CWE-120) [NVD Evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-015039"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-35795"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.6,
            "url": "https://kb.netgear.com/000062735/security-advisory-for-pre-authentication-buffer-overflow-on-some-routers-range-extenders-and-orbi-wifi-systems-psv-2020-0154"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2020-35795"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-015039"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202012-1750"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-35795"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-015039"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202012-1750"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-35795"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2021-09-08T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2020-015039"
          },
          {
            "date": "2020-12-29T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202012-1750"
          },
          {
            "date": "2020-12-30T00:15:14.080000",
            "db": "NVD",
            "id": "CVE-2020-35795"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2021-09-08T08:43:00",
            "db": "JVNDB",
            "id": "JVNDB-2020-015039"
          },
          {
            "date": "2021-01-12T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202012-1750"
          },
          {
            "date": "2024-11-21T05:28:07.420000",
            "db": "NVD",
            "id": "CVE-2020-35795"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202012-1750"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "plural \u00a0NETGEAR\u00a0 Classic buffer overflow vulnerability in device",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-015039"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "other",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202012-1750"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202112-2372

    Vulnerability from variot - Updated: 2024-11-23 23:00

    Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects RBK752 prior to 3.2.16.6, RBR750 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBK852 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, and RBS850 prior to 3.2.16.6

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2372",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "rbr850",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.16.6"
          },
          {
            "model": "rbk752",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.16.6"
          },
          {
            "model": "rbr750",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.16.6"
          },
          {
            "model": "rbk852",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.16.6"
          },
          {
            "model": "rbs850",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.16.6"
          },
          {
            "model": "rbs750",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.16.6"
          },
          {
            "model": "rbk752",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rbr750",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rbs750",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rbr850",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rbs850",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rbk852",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-016886"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45576"
          }
        ]
      },
      "cve": "CVE-2021-45576",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "ADJACENT_NETWORK",
                "authentication": "SINGLE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "PARTIAL",
                "baseScore": 5.2,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 5.1,
                "id": "CVE-2021-45576",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 1.9,
                "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 6.8,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 0.9,
                "id": "CVE-2021-45576",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT",
                "author": "cve@mitre.org",
                "availabilityImpact": "HIGH",
                "baseScore": 8.4,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 1.7,
                "id": "CVE-2021-45576",
                "impactScore": 6.0,
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Adjacent Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 6.8,
                "baseSeverity": "Medium",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "CVE-2021-45576",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "High",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2021-45576",
                "trust": 1.0,
                "value": "MEDIUM"
              },
              {
                "author": "cve@mitre.org",
                "id": "CVE-2021-45576",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "NVD",
                "id": "CVE-2021-45576",
                "trust": 0.8,
                "value": "Medium"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202112-2305",
                "trust": 0.6,
                "value": "MEDIUM"
              },
              {
                "author": "VULMON",
                "id": "CVE-2021-45576",
                "trust": 0.1,
                "value": "MEDIUM"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "VULMON",
            "id": "CVE-2021-45576"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-016886"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2305"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45576"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45576"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects RBK752 prior to 3.2.16.6, RBR750 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBK852 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, and RBS850 prior to 3.2.16.6",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2021-45576"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-016886"
          },
          {
            "db": "VULMON",
            "id": "CVE-2021-45576"
          }
        ],
        "trust": 1.71
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2021-45576",
            "trust": 3.3
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-016886",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2305",
            "trust": 0.6
          },
          {
            "db": "VULMON",
            "id": "CVE-2021-45576",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "VULMON",
            "id": "CVE-2021-45576"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-016886"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2305"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45576"
          }
        ]
      },
      "id": "VAR-202112-2372",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "VARIoT devices database",
            "id": null
          }
        ],
        "trust": 0.14124016
      },
      "last_update_date": "2024-11-23T23:00:59.630000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Security\u00a0Advisory\u00a0for\u00a0Post-Authentication\u00a0Command\u00a0Injection\u00a0on\u00a0Some\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0084",
            "trust": 0.8,
            "url": "https://kb.netgear.com/000064098/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0084"
          },
          {
            "title": "Netgear RBR750  and NETGEAR Fixes for command injection vulnerabilities",
            "trust": 0.6,
            "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=177066"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-016886"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2305"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-77",
            "trust": 1.0
          },
          {
            "problemtype": "Command injection (CWE-77) [NVD evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-016886"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45576"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.7,
            "url": "https://kb.netgear.com/000064098/security-advisory-for-post-authentication-command-injection-on-some-wifi-systems-psv-2020-0084"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45576"
          },
          {
            "trust": 0.1,
            "url": "https://cwe.mitre.org/data/definitions/77.html"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov"
          }
        ],
        "sources": [
          {
            "db": "VULMON",
            "id": "CVE-2021-45576"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-016886"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2305"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45576"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "VULMON",
            "id": "CVE-2021-45576"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-016886"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2305"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45576"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2021-12-26T00:00:00",
            "db": "VULMON",
            "id": "CVE-2021-45576"
          },
          {
            "date": "2022-12-26T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2021-016886"
          },
          {
            "date": "2021-12-25T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202112-2305"
          },
          {
            "date": "2021-12-26T01:15:16.597000",
            "db": "NVD",
            "id": "CVE-2021-45576"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2022-01-04T00:00:00",
            "db": "VULMON",
            "id": "CVE-2021-45576"
          },
          {
            "date": "2022-12-26T05:57:00",
            "db": "JVNDB",
            "id": "JVNDB-2021-016886"
          },
          {
            "date": "2022-01-05T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202112-2305"
          },
          {
            "date": "2024-11-21T06:32:34.057000",
            "db": "NVD",
            "id": "CVE-2021-45576"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote or local",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2305"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "plural \u00a0NETGEAR\u00a0 Command injection vulnerability in device",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-016886"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "command injection",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2305"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202012-1177

    Vulnerability from variot - Updated: 2024-11-23 22:58

    Certain NETGEAR devices are affected by disclosure of sensitive information. This affects CBR40 before 2.5.0.14, RBW30 before 2.6.1.4, RAX75 before 1.0.3.102, RAX80 before 1.0.3.102, RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, RBS850 before 3.2.16.6, RBK842 before 3.2.16.6, RBR840 before 3.2.16.6, RBS840 before 3.2.16.6, and RBS40V before 2.6.1.4. plural NETGEAR An unspecified vulnerability exists in the device.Information may be obtained

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202012-1177",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "cbr40",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "2.5.0.14"
          },
          {
            "model": "rbr840",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.16.6"
          },
          {
            "model": "rbs850",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.16.6"
          },
          {
            "model": "rbs750",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.16.6"
          },
          {
            "model": "rbk852",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.16.6"
          },
          {
            "model": "rbs840",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.16.6"
          },
          {
            "model": "rax80",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.3.102"
          },
          {
            "model": "rbw30",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "2.6.1.4"
          },
          {
            "model": "rbs840v",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "2.6.1.4"
          },
          {
            "model": "rax75",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.3.102"
          },
          {
            "model": "rbk842",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.16.6"
          },
          {
            "model": "rbr750",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.16.6"
          },
          {
            "model": "rbr850",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.16.6"
          },
          {
            "model": "rbk752",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.16.6"
          },
          {
            "model": "rbs750",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rbr850",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rax80",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rbr750",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rax75",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rbs850",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rbk852",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rbk752",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rbw30",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-014795"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-35802"
          }
        ]
      },
      "cve": "CVE-2020-35802",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "NONE",
                "baseScore": 5.0,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 10.0,
                "id": "CVE-2020-35802",
                "impactScore": 2.9,
                "integrityImpact": "NONE",
                "severity": "MEDIUM",
                "trust": 1.8,
                "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "NONE",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "id": "CVE-2020-35802",
                "impactScore": 3.6,
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 2.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "OTHER",
                "availabilityImpact": "None",
                "baseScore": 7.5,
                "baseSeverity": "High",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "JVNDB-2020-014795",
                "impactScore": null,
                "integrityImpact": "None",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2020-35802",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "cve@mitre.org",
                "id": "CVE-2020-35802",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "NVD",
                "id": "CVE-2020-35802",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202012-1767",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-014795"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202012-1767"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-35802"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-35802"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Certain NETGEAR devices are affected by disclosure of sensitive information. This affects CBR40 before 2.5.0.14, RBW30 before 2.6.1.4, RAX75 before 1.0.3.102, RAX80 before 1.0.3.102, RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, RBS850 before 3.2.16.6, RBK842 before 3.2.16.6, RBR840 before 3.2.16.6, RBS840 before 3.2.16.6, and RBS40V before 2.6.1.4. plural NETGEAR An unspecified vulnerability exists in the device.Information may be obtained",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2020-35802"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-014795"
          }
        ],
        "trust": 1.62
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2020-35802",
            "trust": 2.4
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-014795",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202012-1767",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-014795"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202012-1767"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-35802"
          }
        ]
      },
      "id": "VAR-202012-1177",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "VARIoT devices database",
            "id": null
          }
        ],
        "trust": 0.34430966500000004
      },
      "last_update_date": "2024-11-23T22:58:05.584000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Security\u00a0Advisory\u00a0for\u00a0Sensitive\u00a0Information\u00a0Disclosure\u00a0on\u00a0Some\u00a0Routers\u00a0and\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0331",
            "trust": 0.8,
            "url": "https://kb.netgear.com/000062720/Security-Advisory-for-Sensitive-Information-Disclosure-on-Some-Routers-and-WiFi-Systems-PSV-2020-0331"
          },
          {
            "title": "Multiple Netgear Product information disclosure vulnerability repair measures",
            "trust": 0.6,
            "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=138274"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-014795"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202012-1767"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "NVD-CWE-noinfo",
            "trust": 1.0
          },
          {
            "problemtype": "Lack of information (CWE-noinfo) [NVD Evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-014795"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-35802"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.6,
            "url": "https://kb.netgear.com/000062720/security-advisory-for-sensitive-information-disclosure-on-some-routers-and-wifi-systems-psv-2020-0331"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2020-35802"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-014795"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202012-1767"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-35802"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-014795"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202012-1767"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-35802"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2021-08-31T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2020-014795"
          },
          {
            "date": "2020-12-29T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202012-1767"
          },
          {
            "date": "2020-12-30T00:15:14.517000",
            "db": "NVD",
            "id": "CVE-2020-35802"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2021-08-31T05:14:00",
            "db": "JVNDB",
            "id": "JVNDB-2020-014795"
          },
          {
            "date": "2021-01-05T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202012-1767"
          },
          {
            "date": "2024-11-21T05:28:09.167000",
            "db": "NVD",
            "id": "CVE-2020-35802"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202012-1767"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "plural \u00a0NETGEAR\u00a0 Vulnerabilities in devices",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-014795"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "information disclosure",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202012-1767"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202103-1283

    Vulnerability from variot - Updated: 2024-11-23 22:57

    Certain NETGEAR devices are affected by password reset by an unauthenticated attacker. This affects RBK852 before 3.2.10.11, RBK853 before 3.2.10.11, RBR854 before 3.2.10.11, RBR850 before 3.2.10.11, RBS850 before 3.2.10.11, CBR40 before 2.5.0.10, R7000 before 1.0.11.116, R6900P before 1.3.2.126, R7900 before 1.0.4.38, R7960P before 1.4.1.66, R8000 before 1.0.4.66, R7900P before 1.4.1.66, R8000P before 1.4.1.66, RAX75 before 1.0.3.102, RAX80 before 1.0.3.102, and R7000P before 1.3.2.126. plural NETGEAR A vulnerability exists in the device regarding the password management function.Information may be obtained and information may be tampered with. This affects RBK852 prior to 3.2.10.11, RBK853 prior to 3.2.10.11, RBR854 prior to 3.2.10.11, RBR850 prior to 3.2.10.11, RBS850 prior to 3.2.10.11, CBR40 prior to 2.5.0.10, R7000 prior to 1.0.11.116, R6900P prior to 1.3.2.126, R7900 prior to 1.0.4.38, R7960P prior to 1.4.1.66, R8000 prior to 1.0.4.66, R7900P prior to 1.4.1.66, R8000P prior to 1.4.1.66, RAX75 prior to 1.0.3.102, RAX80 prior to 1.0.3.102, and R7000P prior to 1.3.2.126

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202103-1283",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "rbk852",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.10.11"
          },
          {
            "model": "cbr40",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "2.5.0.10"
          },
          {
            "model": "r8000",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.4.66"
          },
          {
            "model": "r7960p",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.4.1.66"
          },
          {
            "model": "r7000",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.11.116"
          },
          {
            "model": "r6900p",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.3.2.126"
          },
          {
            "model": "rbk853",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.10.11"
          },
          {
            "model": "rax80",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.3.102"
          },
          {
            "model": "r7000p",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.3.2.126"
          },
          {
            "model": "rax75",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.3.102"
          },
          {
            "model": "r7900",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.4.38"
          },
          {
            "model": "r8000p",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.4.1.66"
          },
          {
            "model": "r7900p",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.4.1.66"
          },
          {
            "model": "rbs850",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.10.11"
          },
          {
            "model": "rbr850",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.10.11"
          },
          {
            "model": "rbr854",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.10.11"
          },
          {
            "model": "rbk852",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rbk853",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rbr854",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rbr850",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "r7900",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "r6900p",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rbs850",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "r7960p",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "cbr40",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "r7000",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-004585"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-29080"
          }
        ]
      },
      "cve": "CVE-2021-29080",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "ADJACENT_NETWORK",
                "authentication": "NONE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "NONE",
                "baseScore": 4.8,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 6.5,
                "id": "CVE-2021-29080",
                "impactScore": 4.9,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 1.9,
                "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:N",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT",
                "author": "nvd@nist.gov",
                "availabilityImpact": "NONE",
                "baseScore": 8.1,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.8,
                "id": "CVE-2021-29080",
                "impactScore": 5.2,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 2.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Adjacent Network",
                "author": "OTHER",
                "availabilityImpact": "None",
                "baseScore": 8.1,
                "baseSeverity": "High",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "JVNDB-2021-004585",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2021-29080",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "cve@mitre.org",
                "id": "CVE-2021-29080",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "NVD",
                "id": "CVE-2021-29080",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202103-1343",
                "trust": 0.6,
                "value": "HIGH"
              },
              {
                "author": "VULMON",
                "id": "CVE-2021-29080",
                "trust": 0.1,
                "value": "MEDIUM"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "VULMON",
            "id": "CVE-2021-29080"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-004585"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202103-1343"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-29080"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-29080"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Certain NETGEAR devices are affected by password reset by an unauthenticated attacker. This affects RBK852 before 3.2.10.11, RBK853 before 3.2.10.11, RBR854 before 3.2.10.11, RBR850 before 3.2.10.11, RBS850 before 3.2.10.11, CBR40 before 2.5.0.10, R7000 before 1.0.11.116, R6900P before 1.3.2.126, R7900 before 1.0.4.38, R7960P before 1.4.1.66, R8000 before 1.0.4.66, R7900P before 1.4.1.66, R8000P before 1.4.1.66, RAX75 before 1.0.3.102, RAX80 before 1.0.3.102, and R7000P before 1.3.2.126. plural NETGEAR A vulnerability exists in the device regarding the password management function.Information may be obtained and information may be tampered with. This affects RBK852 prior to 3.2.10.11, RBK853 prior to 3.2.10.11, RBR854 prior to 3.2.10.11, RBR850 prior to 3.2.10.11, RBS850 prior to 3.2.10.11, CBR40 prior to 2.5.0.10, R7000 prior to 1.0.11.116, R6900P prior to 1.3.2.126, R7900 prior to 1.0.4.38, R7960P prior to 1.4.1.66, R8000 prior to 1.0.4.66, R7900P prior to 1.4.1.66, R8000P prior to 1.4.1.66, RAX75 prior to 1.0.3.102, RAX80 prior to 1.0.3.102, and R7000P prior to 1.3.2.126",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2021-29080"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-004585"
          },
          {
            "db": "VULMON",
            "id": "CVE-2021-29080"
          }
        ],
        "trust": 1.71
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2021-29080",
            "trust": 2.5
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-004585",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202103-1343",
            "trust": 0.6
          },
          {
            "db": "VULMON",
            "id": "CVE-2021-29080",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "VULMON",
            "id": "CVE-2021-29080"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-004585"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202103-1343"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-29080"
          }
        ]
      },
      "id": "VAR-202103-1283",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "VARIoT devices database",
            "id": null
          }
        ],
        "trust": 0.32459724375000004
      },
      "last_update_date": "2024-11-23T22:57:57.955000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Security\u00a0Advisory\u00a0for\u00a0Pre-authentication\u00a0Password\u00a0Reset\u00a0on\u00a0Some\u00a0Routers\u00a0and\u00a0WiFi\u00a0Systems,\u00a0PSV-2019-0150",
            "trust": 0.8,
            "url": "https://kb.netgear.com/000063007/Security-Advisory-for-Pre-authentication-Password-Reset-on-Some-Routers-and-WiFi-Systems-PSV-2019-0150"
          },
          {
            "title": "Certain NETGEAR Remediation measures for authorization problem vulnerabilities",
            "trust": 0.6,
            "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=145159"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-004585"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202103-1343"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-640",
            "trust": 1.0
          },
          {
            "problemtype": "Weak password recovery mechanism when you forget your password (CWE-640) [NVD Evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-004585"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-29080"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.7,
            "url": "https://kb.netgear.com/000063007/security-advisory-for-pre-authentication-password-reset-on-some-routers-and-wifi-systems-psv-2019-0150"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2021-29080"
          },
          {
            "trust": 0.1,
            "url": "https://cwe.mitre.org/data/definitions/640.html"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov"
          }
        ],
        "sources": [
          {
            "db": "VULMON",
            "id": "CVE-2021-29080"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-004585"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202103-1343"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-29080"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "VULMON",
            "id": "CVE-2021-29080"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-004585"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202103-1343"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-29080"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2021-03-23T00:00:00",
            "db": "VULMON",
            "id": "CVE-2021-29080"
          },
          {
            "date": "2021-11-25T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2021-004585"
          },
          {
            "date": "2021-03-23T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202103-1343"
          },
          {
            "date": "2021-03-23T07:15:14.217000",
            "db": "NVD",
            "id": "CVE-2021-29080"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2021-03-24T00:00:00",
            "db": "VULMON",
            "id": "CVE-2021-29080"
          },
          {
            "date": "2021-11-25T03:10:00",
            "db": "JVNDB",
            "id": "JVNDB-2021-004585"
          },
          {
            "date": "2021-08-16T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202103-1343"
          },
          {
            "date": "2024-11-21T06:00:40.337000",
            "db": "NVD",
            "id": "CVE-2021-29080"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote or local",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202103-1343"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "plural \u00a0NETGEAR\u00a0 Vulnerability related to password management function in devices",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-004585"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "authorization issue",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202103-1343"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202112-2219

    Vulnerability from variot - Updated: 2024-11-23 22:57

    Certain NETGEAR devices are affected by authentication bypass. This affects CBR750 before 4.6.3.6, RBK752 before 3.2.17.12, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12. plural NETGEAR There is an unspecified vulnerability in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects CBR750 prior to 4.6.3.6, RBK752 prior to 3.2.17.12, RBK752 prior to 3.2.17.12, RBR750 prior to 3.2.17.12, RBS750 prior to 3.2.17.12, RBK852 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, and RBS850 prior to 3.2.17.12

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2219",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "rbr750",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.17.12"
          },
          {
            "model": "cbr750",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "4.6.3.6"
          },
          {
            "model": "rbs850",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.17.12"
          },
          {
            "model": "rbs750",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.17.12"
          },
          {
            "model": "rbk852",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.17.12"
          },
          {
            "model": "rbr850",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.17.12"
          },
          {
            "model": "rbk752",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.17.12"
          },
          {
            "model": "rbk752",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rbs850",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rbs750",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rbr750",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "cbr750",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rbk852",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rbr850",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-017140"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45502"
          }
        ]
      },
      "cve": "CVE-2021-45502",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "ADJACENT_NETWORK",
                "authentication": "NONE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "PARTIAL",
                "baseScore": 5.8,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 6.5,
                "id": "CVE-2021-45502",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 1.9,
                "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.8,
                "id": "CVE-2021-45502",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT",
                "author": "cve@mitre.org",
                "availabilityImpact": "HIGH",
                "baseScore": 9.6,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.8,
                "id": "CVE-2021-45502",
                "impactScore": 6.0,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Adjacent Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 8.8,
                "baseSeverity": "High",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "CVE-2021-45502",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2021-45502",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "cve@mitre.org",
                "id": "CVE-2021-45502",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "NVD",
                "id": "CVE-2021-45502",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202112-2319",
                "trust": 0.6,
                "value": "HIGH"
              },
              {
                "author": "VULMON",
                "id": "CVE-2021-45502",
                "trust": 0.1,
                "value": "MEDIUM"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "VULMON",
            "id": "CVE-2021-45502"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-017140"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2319"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45502"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45502"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Certain NETGEAR devices are affected by authentication bypass. This affects CBR750 before 4.6.3.6, RBK752 before 3.2.17.12, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12. plural NETGEAR There is an unspecified vulnerability in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects CBR750 prior to 4.6.3.6, RBK752 prior to 3.2.17.12, RBK752 prior to 3.2.17.12, RBR750 prior to 3.2.17.12, RBS750 prior to 3.2.17.12, RBK852 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, and RBS850 prior to 3.2.17.12",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2021-45502"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-017140"
          },
          {
            "db": "VULMON",
            "id": "CVE-2021-45502"
          }
        ],
        "trust": 1.71
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2021-45502",
            "trust": 3.3
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-017140",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2319",
            "trust": 0.6
          },
          {
            "db": "VULMON",
            "id": "CVE-2021-45502",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "VULMON",
            "id": "CVE-2021-45502"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-017140"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2319"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45502"
          }
        ]
      },
      "id": "VAR-202112-2219",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "VARIoT devices database",
            "id": null
          }
        ],
        "trust": 0.14124016
      },
      "last_update_date": "2024-11-23T22:57:50.445000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Security\u00a0Advisory\u00a0for\u00a0Authentication\u00a0Bypass\u00a0on\u00a0Some\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0473",
            "trust": 0.8,
            "url": "https://kb.netgear.com/000064126/Security-Advisory-for-Authentication-Bypass-on-Some-WiFi-Systems-PSV-2020-0473"
          },
          {
            "title": "Netgear RBR750  and NETGEAR Security vulnerabilities",
            "trust": 0.6,
            "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=176038"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-017140"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2319"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "NVD-CWE-noinfo",
            "trust": 1.0
          },
          {
            "problemtype": "Lack of information (CWE-noinfo) [NVD evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-017140"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45502"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.7,
            "url": "https://kb.netgear.com/000064126/security-advisory-for-authentication-bypass-on-some-wifi-systems-psv-2020-0473"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45502"
          },
          {
            "trust": 0.1,
            "url": "https://cwe.mitre.org/data/definitions/287.html"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov"
          }
        ],
        "sources": [
          {
            "db": "VULMON",
            "id": "CVE-2021-45502"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-017140"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2319"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45502"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "VULMON",
            "id": "CVE-2021-45502"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-017140"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2319"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45502"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2021-12-26T00:00:00",
            "db": "VULMON",
            "id": "CVE-2021-45502"
          },
          {
            "date": "2023-01-05T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2021-017140"
          },
          {
            "date": "2021-12-26T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202112-2319"
          },
          {
            "date": "2021-12-26T01:15:12.983000",
            "db": "NVD",
            "id": "CVE-2021-45502"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2022-01-05T00:00:00",
            "db": "VULMON",
            "id": "CVE-2021-45502"
          },
          {
            "date": "2023-01-05T02:24:00",
            "db": "JVNDB",
            "id": "JVNDB-2021-017140"
          },
          {
            "date": "2022-07-14T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202112-2319"
          },
          {
            "date": "2024-11-21T06:32:21.600000",
            "db": "NVD",
            "id": "CVE-2021-45502"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote or local",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2319"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "plural \u00a0NETGEAR\u00a0 Vulnerabilities in devices",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-017140"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "authorization issue",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2319"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202112-2328

    Vulnerability from variot - Updated: 2024-11-23 22:57

    Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR40 before 2.5.0.24, CBR750 before 3.2.18.2, EAX20 before 1.0.0.58, EAX80 before 1.0.1.68, EX3700 before 1.0.0.94, EX3800 before 1.0.0.94, EX6120 before 1.0.0.64, EX6130 before 1.0.0.44, EX7000 before 1.0.1.104, EX7500 before 1.0.0.74, LAX20 before 1.1.6.28, MR60 before 1.0.6.116, MS60 before 1.0.6.116, R6300v2 before 1.0.4.52, R6400 before 1.0.1.70, R6400v2 before 1.0.4.106, R6700v3 before 1.0.4.106, R6900P before 1.3.3.140, R7000 before 1.0.11.126, R7000P before 1.3.3.140, R7100LG before 1.0.0.72, R7850 before 1.0.5.74, R7900 before 1.0.4.46, R7900P before 1.4.2.84, R7960P before 1.4.2.84, R8000 before 1.0.4.74, R8000P before 1.4.2.84, R8300 before 1.0.2.154, R8500 before 1.0.2.154, RAX15 before 1.0.3.96, RAX20 before 1.0.3.96, RAX200 before 1.0.4.120, RAX35v2 before 1.0.3.96, RAX40v2 before 1.0.3.96, RAX43 before 1.0.3.96, RAX45 before 1.0.3.96, RAX50 before 1.0.3.96, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK752 before 3.2.17.12, RBK852 before 3.2.17.12, RBK852 before 3.2.17.12, RBR750 before 3.2.17.12, RBR850 before 3.2.17.12, RBR850 before 3.2.17.12, RBS750 before 3.2.17.12, RBS850 before 3.2.17.12, RBS850 before 3.2.17.12, RS400 before 1.5.1.80, XR1000 before 1.0.0.58, and XR300 before 1.0.3.68. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects CBR40 prior to 2.5.0.24, CBR750 prior to 3.2.18.2, EAX20 prior to 1.0.0.58, EAX80 prior to 1.0.1.68, EX3700 prior to 1.0.0.94, EX3800 prior to 1.0.0.94, EX6120 prior to 1.0.0.64, EX6130 prior to 1.0.0.44, EX7000 prior to 1.0.1.104, EX7500 prior to 1.0.0.74, LAX20 prior to 1.1.6.28, MR60 prior to 1.0.6.116, MS60 prior to 1.0.6.116, R6300v2 prior to 1.0.4.52, R6400 prior to 1.0.1.70, R6400v2 prior to 1.0.4.106, R6700v3 prior to 1.0.4.106, R6900P prior to 1.3.3.140, R7000 prior to 1.0.11.126, R7000P prior to 1.3.3.140, R7100LG prior to 1.0.0.72, R7850 prior to 1.0.5.74, R7900 prior to 1.0.4.46, R7900P prior to 1.4.2.84, R7960P prior to 1.4.2.84, R8000 prior to 1.0.4.74, R8000P prior to 1.4.2.84, R8300 prior to 1.0.2.154, R8500 prior to 1.0.2.154, RAX15 prior to 1.0.3.96, RAX20 prior to 1.0.3.96, RAX200 prior to 1.0.4.120, RAX35v2 prior to 1.0.3.96, RAX40v2 prior to 1.0.3.96, RAX43 prior to 1.0.3.96, RAX45 prior to 1.0.3.96, RAX50 prior to 1.0.3.96, RAX75 prior to 1.0.4.120, RAX80 prior to 1.0.4.120, RBK752 prior to 3.2.17.12, RBK852 prior to 3.2.17.12, RBK852 prior to 3.2.17.12, RBR750 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, RBS750 prior to 3.2.17.12, RBS850 prior to 3.2.17.12, RBS850 prior to 3.2.17.12, RS400 prior to 1.5.1.80, XR1000 prior to 1.0.0.58, and XR300 prior to 1.0.3.68

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2328",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "rbr750",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.17.12"
          },
          {
            "model": "mr60",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.6.116"
          },
          {
            "model": "r6400",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.1.70"
          },
          {
            "model": "ex6120",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.0.64"
          },
          {
            "model": "ms60",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.6.116"
          },
          {
            "model": "rax45",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.3.96"
          },
          {
            "model": "rax15",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.3.96"
          },
          {
            "model": "rbk752",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.17.12"
          },
          {
            "model": "r8000p",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.4.2.84"
          },
          {
            "model": "ex6130",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.0.44"
          },
          {
            "model": "r7900p",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.4.2.84"
          },
          {
            "model": "eax20",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.0.58"
          },
          {
            "model": "rax43",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.3.96"
          },
          {
            "model": "cbr750",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.18.2"
          },
          {
            "model": "eax80",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.1.68"
          },
          {
            "model": "rbr850",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.17.12"
          },
          {
            "model": "r7850",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.5.74"
          },
          {
            "model": "r7900",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.4.46"
          },
          {
            "model": "rax80",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.4.120"
          },
          {
            "model": "rs400",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.5.1.80"
          },
          {
            "model": "r8500",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.2.154"
          },
          {
            "model": "r7000p",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.3.3.140"
          },
          {
            "model": "rbs750",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.17.12"
          },
          {
            "model": "cbr40",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "2.5.0.24"
          },
          {
            "model": "r6400v2",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.4.106"
          },
          {
            "model": "xr1000",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.0.58"
          },
          {
            "model": "rbs850",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.17.12"
          },
          {
            "model": "rax50",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.3.96"
          },
          {
            "model": "ex3800",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.0.94"
          },
          {
            "model": "rax40v2",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.3.96"
          },
          {
            "model": "lax20",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.1.6.28"
          },
          {
            "model": "r6900p",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.3.3.140"
          },
          {
            "model": "r7100lg",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.0.72"
          },
          {
            "model": "rax35v2",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.3.96"
          },
          {
            "model": "rbk852",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.17.12"
          },
          {
            "model": "rax200",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.4.120"
          },
          {
            "model": "xr300",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.3.68"
          },
          {
            "model": "r8000",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.4.74"
          },
          {
            "model": "r8300",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.2.154"
          },
          {
            "model": "r6300v2",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.4.52"
          },
          {
            "model": "r7960p",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.4.2.84"
          },
          {
            "model": "rax75",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.4.120"
          },
          {
            "model": "ex7000",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.1.104"
          },
          {
            "model": "r7000",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.11.126"
          },
          {
            "model": "ex7500",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.0.74"
          },
          {
            "model": "rax20",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.3.96"
          },
          {
            "model": "ex3700",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.0.94"
          },
          {
            "model": "r6700v3",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.4.106"
          },
          {
            "model": "rax35v2",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "eax20",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "cbr750",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rax200",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rax20",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rax40v2",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rax15",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "eax80",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "cbr40",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rax43",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-017547"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45621"
          }
        ]
      },
      "cve": "CVE-2021-45621",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "COMPLETE",
                "baseScore": 10.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 10.0,
                "id": "CVE-2021-45621",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 1.8,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "id": "CVE-2021-45621",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT",
                "author": "cve@mitre.org",
                "availabilityImpact": "HIGH",
                "baseScore": 9.6,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.8,
                "id": "CVE-2021-45621",
                "impactScore": 6.0,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 9.8,
                "baseSeverity": "Critical",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "CVE-2021-45621",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2021-45621",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "cve@mitre.org",
                "id": "CVE-2021-45621",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "NVD",
                "id": "CVE-2021-45621",
                "trust": 0.8,
                "value": "Critical"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202112-2417",
                "trust": 0.6,
                "value": "CRITICAL"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-017547"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2417"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45621"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45621"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects CBR40 before 2.5.0.24, CBR750 before 3.2.18.2, EAX20 before 1.0.0.58, EAX80 before 1.0.1.68, EX3700 before 1.0.0.94, EX3800 before 1.0.0.94, EX6120 before 1.0.0.64, EX6130 before 1.0.0.44, EX7000 before 1.0.1.104, EX7500 before 1.0.0.74, LAX20 before 1.1.6.28, MR60 before 1.0.6.116, MS60 before 1.0.6.116, R6300v2 before 1.0.4.52, R6400 before 1.0.1.70, R6400v2 before 1.0.4.106, R6700v3 before 1.0.4.106, R6900P before 1.3.3.140, R7000 before 1.0.11.126, R7000P before 1.3.3.140, R7100LG before 1.0.0.72, R7850 before 1.0.5.74, R7900 before 1.0.4.46, R7900P before 1.4.2.84, R7960P before 1.4.2.84, R8000 before 1.0.4.74, R8000P before 1.4.2.84, R8300 before 1.0.2.154, R8500 before 1.0.2.154, RAX15 before 1.0.3.96, RAX20 before 1.0.3.96, RAX200 before 1.0.4.120, RAX35v2 before 1.0.3.96, RAX40v2 before 1.0.3.96, RAX43 before 1.0.3.96, RAX45 before 1.0.3.96, RAX50 before 1.0.3.96, RAX75 before 1.0.4.120, RAX80 before 1.0.4.120, RBK752 before 3.2.17.12, RBK852 before 3.2.17.12, RBK852 before 3.2.17.12, RBR750 before 3.2.17.12, RBR850 before 3.2.17.12, RBR850 before 3.2.17.12, RBS750 before 3.2.17.12, RBS850 before 3.2.17.12, RBS850 before 3.2.17.12, RS400 before 1.5.1.80, XR1000 before 1.0.0.58, and XR300 before 1.0.3.68. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects CBR40 prior to 2.5.0.24, CBR750 prior to 3.2.18.2, EAX20 prior to 1.0.0.58, EAX80 prior to 1.0.1.68, EX3700 prior to 1.0.0.94, EX3800 prior to 1.0.0.94, EX6120 prior to 1.0.0.64, EX6130 prior to 1.0.0.44, EX7000 prior to 1.0.1.104, EX7500 prior to 1.0.0.74, LAX20 prior to 1.1.6.28, MR60 prior to 1.0.6.116, MS60 prior to 1.0.6.116, R6300v2 prior to 1.0.4.52, R6400 prior to 1.0.1.70, R6400v2 prior to 1.0.4.106, R6700v3 prior to 1.0.4.106, R6900P prior to 1.3.3.140, R7000 prior to 1.0.11.126, R7000P prior to 1.3.3.140, R7100LG prior to 1.0.0.72, R7850 prior to 1.0.5.74, R7900 prior to 1.0.4.46, R7900P prior to 1.4.2.84, R7960P prior to 1.4.2.84, R8000 prior to 1.0.4.74, R8000P prior to 1.4.2.84, R8300 prior to 1.0.2.154, R8500 prior to 1.0.2.154, RAX15 prior to 1.0.3.96, RAX20 prior to 1.0.3.96, RAX200 prior to 1.0.4.120, RAX35v2 prior to 1.0.3.96, RAX40v2 prior to 1.0.3.96, RAX43 prior to 1.0.3.96, RAX45 prior to 1.0.3.96, RAX50 prior to 1.0.3.96, RAX75 prior to 1.0.4.120, RAX80 prior to 1.0.4.120, RBK752 prior to 3.2.17.12, RBK852 prior to 3.2.17.12, RBK852 prior to 3.2.17.12, RBR750 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, RBR850 prior to 3.2.17.12, RBS750 prior to 3.2.17.12, RBS850 prior to 3.2.17.12, RBS850 prior to 3.2.17.12, RS400 prior to 1.5.1.80, XR1000 prior to 1.0.0.58, and XR300 prior to 1.0.3.68",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2021-45621"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-017547"
          },
          {
            "db": "VULMON",
            "id": "CVE-2021-45621"
          }
        ],
        "trust": 1.71
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2021-45621",
            "trust": 3.3
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-017547",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2417",
            "trust": 0.6
          },
          {
            "db": "VULMON",
            "id": "CVE-2021-45621",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "VULMON",
            "id": "CVE-2021-45621"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-017547"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2417"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45621"
          }
        ]
      },
      "id": "VAR-202112-2328",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "VARIoT devices database",
            "id": null
          }
        ],
        "trust": 0.3596940220833333
      },
      "last_update_date": "2024-11-23T22:57:50.345000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Security\u00a0Advisory\u00a0for\u00a0Pre-Authentication\u00a0Command\u00a0Injection\u00a0on\u00a0Some\u00a0Routers,\u00a0Extenders,\u00a0and\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0562",
            "trust": 0.8,
            "url": "https://kb.netgear.com/000064523/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Routers-Extenders-and-WiFi-Systems-PSV-2020-0562"
          },
          {
            "title": "Netgear RBR750  and NETGEAR Security vulnerabilities",
            "trust": 0.6,
            "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=176396"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-017547"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2417"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-77",
            "trust": 1.0
          },
          {
            "problemtype": "Command injection (CWE-77) [NVD evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-017547"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45621"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.7,
            "url": "https://kb.netgear.com/000064523/security-advisory-for-pre-authentication-command-injection-on-some-routers-extenders-and-wifi-systems-psv-2020-0562"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45621"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov"
          }
        ],
        "sources": [
          {
            "db": "VULMON",
            "id": "CVE-2021-45621"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-017547"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2417"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45621"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "VULMON",
            "id": "CVE-2021-45621"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-017547"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2417"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45621"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2021-12-26T00:00:00",
            "db": "VULMON",
            "id": "CVE-2021-45621"
          },
          {
            "date": "2023-01-25T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2021-017547"
          },
          {
            "date": "2021-12-26T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202112-2417"
          },
          {
            "date": "2021-12-26T01:15:18.757000",
            "db": "NVD",
            "id": "CVE-2021-45621"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2021-12-27T00:00:00",
            "db": "VULMON",
            "id": "CVE-2021-45621"
          },
          {
            "date": "2023-01-25T02:07:00",
            "db": "JVNDB",
            "id": "JVNDB-2021-017547"
          },
          {
            "date": "2022-01-11T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202112-2417"
          },
          {
            "date": "2024-11-21T06:32:41.920000",
            "db": "NVD",
            "id": "CVE-2021-45621"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2417"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "plural \u00a0NETGEAR\u00a0 Command injection vulnerability in device",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-017547"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "command injection",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2417"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202112-2370

    Vulnerability from variot - Updated: 2024-11-23 22:57

    Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects RBK752 prior to 3.2.16.6, RBR750 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBK852 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, and RBS850 prior to 3.2.16.6

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2370",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "rbr850",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.16.6"
          },
          {
            "model": "rbk752",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.16.6"
          },
          {
            "model": "rbr750",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.16.6"
          },
          {
            "model": "rbk852",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.16.6"
          },
          {
            "model": "rbs850",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.16.6"
          },
          {
            "model": "rbs750",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.16.6"
          },
          {
            "model": "rbk752",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rbr750",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rbs750",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rbr850",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rbs850",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rbk852",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-016888"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45578"
          }
        ]
      },
      "cve": "CVE-2021-45578",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "ADJACENT_NETWORK",
                "authentication": "SINGLE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "PARTIAL",
                "baseScore": 5.2,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 5.1,
                "id": "CVE-2021-45578",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 1.9,
                "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 6.8,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 0.9,
                "id": "CVE-2021-45578",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT",
                "author": "cve@mitre.org",
                "availabilityImpact": "HIGH",
                "baseScore": 8.4,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 1.7,
                "id": "CVE-2021-45578",
                "impactScore": 6.0,
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Adjacent Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 6.8,
                "baseSeverity": "Medium",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "CVE-2021-45578",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "High",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2021-45578",
                "trust": 1.0,
                "value": "MEDIUM"
              },
              {
                "author": "cve@mitre.org",
                "id": "CVE-2021-45578",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "NVD",
                "id": "CVE-2021-45578",
                "trust": 0.8,
                "value": "Medium"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202112-2377",
                "trust": 0.6,
                "value": "MEDIUM"
              },
              {
                "author": "VULMON",
                "id": "CVE-2021-45578",
                "trust": 0.1,
                "value": "MEDIUM"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "VULMON",
            "id": "CVE-2021-45578"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-016888"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2377"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45578"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45578"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6. plural NETGEAR A command injection vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This affects RBK752 prior to 3.2.16.6, RBR750 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBK852 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, and RBS850 prior to 3.2.16.6",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2021-45578"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-016888"
          },
          {
            "db": "VULMON",
            "id": "CVE-2021-45578"
          }
        ],
        "trust": 1.71
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2021-45578",
            "trust": 3.3
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-016888",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2377",
            "trust": 0.6
          },
          {
            "db": "VULMON",
            "id": "CVE-2021-45578",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "VULMON",
            "id": "CVE-2021-45578"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-016888"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2377"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45578"
          }
        ]
      },
      "id": "VAR-202112-2370",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "VARIoT devices database",
            "id": null
          }
        ],
        "trust": 0.14124016
      },
      "last_update_date": "2024-11-23T22:57:50.296000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Security\u00a0Advisory\u00a0for\u00a0Post-Authentication\u00a0Command\u00a0Injection\u00a0on\u00a0Some\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0086",
            "trust": 0.8,
            "url": "https://kb.netgear.com/000064100/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0086"
          },
          {
            "title": "Netgear RBR750  and NETGEAR Fixes for command injection vulnerabilities",
            "trust": 0.6,
            "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=177087"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-016888"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2377"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-77",
            "trust": 1.0
          },
          {
            "problemtype": "Command injection (CWE-77) [NVD evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-016888"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45578"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.7,
            "url": "https://kb.netgear.com/000064100/security-advisory-for-post-authentication-command-injection-on-some-wifi-systems-psv-2020-0086"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45578"
          },
          {
            "trust": 0.1,
            "url": "https://cwe.mitre.org/data/definitions/77.html"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov"
          }
        ],
        "sources": [
          {
            "db": "VULMON",
            "id": "CVE-2021-45578"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-016888"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2377"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45578"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "VULMON",
            "id": "CVE-2021-45578"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-016888"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2377"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45578"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2021-12-26T00:00:00",
            "db": "VULMON",
            "id": "CVE-2021-45578"
          },
          {
            "date": "2022-12-26T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2021-016888"
          },
          {
            "date": "2021-12-26T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202112-2377"
          },
          {
            "date": "2021-12-26T01:15:16.697000",
            "db": "NVD",
            "id": "CVE-2021-45578"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2022-01-04T00:00:00",
            "db": "VULMON",
            "id": "CVE-2021-45578"
          },
          {
            "date": "2022-12-26T06:07:00",
            "db": "JVNDB",
            "id": "JVNDB-2021-016888"
          },
          {
            "date": "2022-01-05T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202112-2377"
          },
          {
            "date": "2024-11-21T06:32:34.410000",
            "db": "NVD",
            "id": "CVE-2021-45578"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote or local",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2377"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "plural \u00a0NETGEAR\u00a0 Command injection vulnerability in device",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-016888"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "command injection",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2377"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202112-2412

    Vulnerability from variot - Updated: 2024-11-23 22:57

    Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RAX75 before 1.0.3.106, RAX80 before 1.0.3.106, RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6. (DoS) It may be in a state. This affects RAX75 prior to 1.0.3.106, RAX80 prior to 1.0.3.106, RBK752 prior to 3.2.16.6, RBR750 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBK852 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, and RBS850 prior to 3.2.16.6

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2412",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "rbr850",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.16.6"
          },
          {
            "model": "rbk752",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.16.6"
          },
          {
            "model": "rbr750",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.16.6"
          },
          {
            "model": "rbk852",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.16.6"
          },
          {
            "model": "rbs850",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.16.6"
          },
          {
            "model": "rax75",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.3.106"
          },
          {
            "model": "rbs750",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.16.6"
          },
          {
            "model": "rax80",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.3.106"
          },
          {
            "model": "rbr750",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rax75",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rbk752",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rax80",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rbk852",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rbs750",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rbr850",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rbs850",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-017102"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45536"
          }
        ]
      },
      "cve": "CVE-2021-45536",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "ADJACENT_NETWORK",
                "authentication": "SINGLE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "PARTIAL",
                "baseScore": 5.2,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 5.1,
                "id": "CVE-2021-45536",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 1.9,
                "vectorString": "AV:A/AC:L/Au:S/C:P/I:P/A:P",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 6.8,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 0.9,
                "id": "CVE-2021-45536",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT",
                "author": "cve@mitre.org",
                "availabilityImpact": "HIGH",
                "baseScore": 8.4,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 1.7,
                "id": "CVE-2021-45536",
                "impactScore": 6.0,
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Adjacent Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 6.8,
                "baseSeverity": "Medium",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "CVE-2021-45536",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "High",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2021-45536",
                "trust": 1.0,
                "value": "MEDIUM"
              },
              {
                "author": "cve@mitre.org",
                "id": "CVE-2021-45536",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "NVD",
                "id": "CVE-2021-45536",
                "trust": 0.8,
                "value": "Medium"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202112-2350",
                "trust": 0.6,
                "value": "MEDIUM"
              },
              {
                "author": "VULMON",
                "id": "CVE-2021-45536",
                "trust": 0.1,
                "value": "MEDIUM"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "VULMON",
            "id": "CVE-2021-45536"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-017102"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2350"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45536"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45536"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RAX75 before 1.0.3.106, RAX80 before 1.0.3.106, RBK752 before 3.2.16.6, RBR750 before 3.2.16.6, RBS750 before 3.2.16.6, RBK852 before 3.2.16.6, RBR850 before 3.2.16.6, and RBS850 before 3.2.16.6. (DoS) It may be in a state. This affects RAX75 prior to 1.0.3.106, RAX80 prior to 1.0.3.106, RBK752 prior to 3.2.16.6, RBR750 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBK852 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, and RBS850 prior to 3.2.16.6",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2021-45536"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-017102"
          },
          {
            "db": "VULMON",
            "id": "CVE-2021-45536"
          }
        ],
        "trust": 1.71
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2021-45536",
            "trust": 3.3
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-017102",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2350",
            "trust": 0.6
          },
          {
            "db": "VULMON",
            "id": "CVE-2021-45536",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "VULMON",
            "id": "CVE-2021-45536"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-017102"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2350"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45536"
          }
        ]
      },
      "id": "VAR-202112-2412",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "VARIoT devices database",
            "id": null
          }
        ],
        "trust": 0.14124016
      },
      "last_update_date": "2024-11-23T22:57:50.248000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Security\u00a0Advisory\u00a0for\u00a0Post-Authentication\u00a0Command\u00a0Injection\u00a0on\u00a0Some\u00a0Routers\u00a0and\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0056",
            "trust": 0.8,
            "url": "https://kb.netgear.com/000064080/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Routers-and-WiFi-Systems-PSV-2020-0056"
          },
          {
            "title": "Netgear RBR750  and NETGEAR Security vulnerabilities",
            "trust": 0.6,
            "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=176383"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-017102"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2350"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-77",
            "trust": 1.0
          },
          {
            "problemtype": "Command injection (CWE-77) [NVD evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-017102"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45536"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.7,
            "url": "https://kb.netgear.com/000064080/security-advisory-for-post-authentication-command-injection-on-some-routers-and-wifi-systems-psv-2020-0056"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45536"
          },
          {
            "trust": 0.1,
            "url": "https://cwe.mitre.org/data/definitions/77.html"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov"
          }
        ],
        "sources": [
          {
            "db": "VULMON",
            "id": "CVE-2021-45536"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-017102"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2350"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45536"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "VULMON",
            "id": "CVE-2021-45536"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-017102"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2350"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45536"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2021-12-26T00:00:00",
            "db": "VULMON",
            "id": "CVE-2021-45536"
          },
          {
            "date": "2023-01-04T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2021-017102"
          },
          {
            "date": "2021-12-26T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202112-2350"
          },
          {
            "date": "2021-12-26T01:15:14.697000",
            "db": "NVD",
            "id": "CVE-2021-45536"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2022-01-05T00:00:00",
            "db": "VULMON",
            "id": "CVE-2021-45536"
          },
          {
            "date": "2023-01-04T06:51:00",
            "db": "JVNDB",
            "id": "JVNDB-2021-017102"
          },
          {
            "date": "2022-01-10T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202112-2350"
          },
          {
            "date": "2024-11-21T06:32:27.143000",
            "db": "NVD",
            "id": "CVE-2021-45536"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote or local",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2350"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "plural \u00a0NETGEAR\u00a0 Command Injection Vulnerability in Command Injection Vulnerability in Devices",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-017102"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "command injection",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2350"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202006-0937

    Vulnerability from variot - Updated: 2024-11-23 22:55

    Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25. plural NETGEAR On the device OS A command injection vulnerability exists.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. NETGEAR RBK752, etc. are all home WiFi systems of NETGEAR. Attackers can use this vulnerability to execute arbitrary Shell commands on the system by sending a specially crafted request

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202006-0937",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "rbk752",
            "scope": "lt",
            "trust": 1.6,
            "vendor": "netgear",
            "version": "3.2.15.25"
          },
          {
            "model": "rbr750",
            "scope": "lt",
            "trust": 1.6,
            "vendor": "netgear",
            "version": "3.2.15.25"
          },
          {
            "model": "rbs750",
            "scope": "lt",
            "trust": 1.6,
            "vendor": "netgear",
            "version": "3.2.15.25"
          },
          {
            "model": "rbk753",
            "scope": "lt",
            "trust": 1.6,
            "vendor": "netgear",
            "version": "3.2.15.25"
          },
          {
            "model": "rbk753s",
            "scope": "lt",
            "trust": 1.6,
            "vendor": "netgear",
            "version": "3.2.15.25"
          },
          {
            "model": "rbk842",
            "scope": "lt",
            "trust": 1.6,
            "vendor": "netgear",
            "version": "3.2.15.25"
          },
          {
            "model": "rbr840",
            "scope": "lt",
            "trust": 1.6,
            "vendor": "netgear",
            "version": "3.2.15.25"
          },
          {
            "model": "rbs840",
            "scope": "lt",
            "trust": 1.6,
            "vendor": "netgear",
            "version": "3.2.15.25"
          },
          {
            "model": "rbk852",
            "scope": "lt",
            "trust": 1.6,
            "vendor": "netgear",
            "version": "3.2.15.25"
          },
          {
            "model": "rbk853",
            "scope": "lt",
            "trust": 1.6,
            "vendor": "netgear",
            "version": "3.2.15.25"
          },
          {
            "model": "rbr850",
            "scope": "lt",
            "trust": 1.6,
            "vendor": "netgear",
            "version": "3.2.15.25"
          },
          {
            "model": "rbs850",
            "scope": "lt",
            "trust": 1.6,
            "vendor": "netgear",
            "version": "3.2.15.25"
          },
          {
            "model": "rbk752",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "netgear",
            "version": "3.2.15.25"
          },
          {
            "model": "rbk753",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "netgear",
            "version": "3.2.15.25"
          },
          {
            "model": "rbk753s",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "netgear",
            "version": "3.2.15.25"
          },
          {
            "model": "rbk842",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "netgear",
            "version": "3.2.15.25"
          },
          {
            "model": "rbk852",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "netgear",
            "version": "3.2.15.25"
          },
          {
            "model": "rbk853",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "netgear",
            "version": "3.2.15.25"
          },
          {
            "model": "rbr750",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "netgear",
            "version": "3.2.15.25"
          },
          {
            "model": "rbr840",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "netgear",
            "version": "3.2.15.25"
          },
          {
            "model": "rbs750",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "netgear",
            "version": "3.2.15.25"
          },
          {
            "model": "rbs840",
            "scope": "eq",
            "trust": 0.8,
            "vendor": "netgear",
            "version": "3.2.15.25"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-44785"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-006681"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-14440"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "cpe_match": [
                  {
                    "cpe22Uri": "cpe:/o:netgear:rbk752_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:netgear:rbk753_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:netgear:rbk753s_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:netgear:rbk842_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:netgear:rbk852_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:netgear:rbk853_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:netgear:rbr750_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:netgear:rbr840_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:netgear:rbs750_firmware",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:netgear:rbs840_firmware",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-006681"
          }
        ]
      },
      "cve": "CVE-2020-14440",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "ADJACENT_NETWORK",
                "authentication": "NONE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "PARTIAL",
                "baseScore": 5.8,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 6.5,
                "id": "CVE-2020-14440",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 1.0,
                "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P",
                "version": "2.0"
              },
              {
                "acInsufInfo": null,
                "accessComplexity": "Low",
                "accessVector": "Adjacent Network",
                "authentication": "None",
                "author": "NVD",
                "availabilityImpact": "Partial",
                "baseScore": 5.8,
                "confidentialityImpact": "Partial",
                "exploitabilityScore": null,
                "id": "JVNDB-2020-006681",
                "impactScore": null,
                "integrityImpact": "Partial",
                "obtainAllPrivilege": null,
                "obtainOtherPrivilege": null,
                "obtainUserPrivilege": null,
                "severity": "Medium",
                "trust": 0.8,
                "userInteractionRequired": null,
                "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "ADJACENT_NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "PARTIAL",
                "baseScore": 5.8,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 6.5,
                "id": "CNVD-2021-44785",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 0.6,
                "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.8,
                "id": "CVE-2020-14440",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT",
                "author": "cve@mitre.org",
                "availabilityImpact": "LOW",
                "baseScore": 9.6,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.8,
                "id": "CVE-2020-14440",
                "impactScore": 6.0,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:L",
                "version": "3.0"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Adjacent Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 8.8,
                "baseSeverity": "High",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "JVNDB-2020-006681",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2020-14440",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "cve@mitre.org",
                "id": "CVE-2020-14440",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "NVD",
                "id": "JVNDB-2020-006681",
                "trust": 0.8,
                "value": "High"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2021-44785",
                "trust": 0.6,
                "value": "MEDIUM"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202006-1259",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-44785"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-006681"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202006-1259"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-14440"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-14440"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25. plural NETGEAR On the device OS A command injection vulnerability exists.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. NETGEAR RBK752, etc. are all home WiFi systems of NETGEAR. Attackers can use this vulnerability to execute arbitrary Shell commands on the system by sending a specially crafted request",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2020-14440"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-006681"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2021-44785"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2020-14440",
            "trust": 3.0
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-006681",
            "trust": 0.8
          },
          {
            "db": "CNVD",
            "id": "CNVD-2021-44785",
            "trust": 0.6
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202006-1259",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-44785"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-006681"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202006-1259"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-14440"
          }
        ]
      },
      "id": "VAR-202006-0937",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-44785"
          }
        ],
        "trust": 1.0097272085714286
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-44785"
          }
        ]
      },
      "last_update_date": "2024-11-23T22:55:07.986000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Security Advisory for Pre-Authentification Command Injection on Some WiFi Systems, PSV-2020-0065",
            "trust": 0.8,
            "url": "https://kb.netgear.com/000061943/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-WiFi-Systems-PSV-2020-0065"
          },
          {
            "title": "Patch for Operating system command injection vulnerabilities in multiple NETGEAR products (CNVD-2021-44785)",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/275041"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-44785"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-006681"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-77",
            "trust": 1.0
          },
          {
            "problemtype": "CWE-78",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-006681"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-14440"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.0,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2020-14440"
          },
          {
            "trust": 1.6,
            "url": "https://kb.netgear.com/000061943/security-advisory-for-pre-authentication-command-injection-on-some-wifi-systems-psv-2020-0065"
          },
          {
            "trust": 0.8,
            "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-14440"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-44785"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-006681"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202006-1259"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-14440"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2021-44785"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-006681"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202006-1259"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-14440"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2020-06-24T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2021-44785"
          },
          {
            "date": "2020-07-15T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2020-006681"
          },
          {
            "date": "2020-06-18T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202006-1259"
          },
          {
            "date": "2020-06-18T17:15:13.140000",
            "db": "NVD",
            "id": "CVE-2020-14440"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2021-06-24T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2021-44785"
          },
          {
            "date": "2020-07-15T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2020-006681"
          },
          {
            "date": "2020-07-02T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202006-1259"
          },
          {
            "date": "2024-11-21T05:03:16.930000",
            "db": "NVD",
            "id": "CVE-2020-14440"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote or local",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202006-1259"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "plural  NETGEAR On the device  OS Command injection vulnerabilities",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-006681"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "operating system commend injection",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202006-1259"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202010-0916

    Vulnerability from variot - Updated: 2024-11-23 22:54

    Certain NETGEAR devices are affected by authentication bypass. This affects CBR40 before 2.5.0.10, RBK752 before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.10.11, RBR850 before 3.2.10.11, and RBS850 before 3.2.10.11. plural NETGEAR There is an authentication vulnerability in the device.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202010-0916",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "rbk852",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.10.11"
          },
          {
            "model": "cbr40",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "2.5.0.10"
          },
          {
            "model": "rbr750",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.15.25"
          },
          {
            "model": "rbk752",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.15.25"
          },
          {
            "model": "rbs850",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.10.11"
          },
          {
            "model": "rbs750",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.15.25"
          },
          {
            "model": "rbr850",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.10.11"
          },
          {
            "model": "cbr40",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rbk752",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rbk852",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rbr750",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rbr850",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rbs750",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rbs850",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-012204"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-26926"
          }
        ]
      },
      "cve": "CVE-2020-26926",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "ADJACENT_NETWORK",
                "authentication": "NONE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "PARTIAL",
                "baseScore": 5.8,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 6.5,
                "id": "CVE-2020-26926",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 1.8,
                "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 9.6,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 2.8,
                "id": "CVE-2020-26926",
                "impactScore": 6.0,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "trust": 2.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Adjacent Network",
                "author": "OTHER",
                "availabilityImpact": "High",
                "baseScore": 9.6,
                "baseSeverity": "Critical",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "JVNDB-2020-012204",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Changed",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2020-26926",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "cve@mitre.org",
                "id": "CVE-2020-26926",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "NVD",
                "id": "CVE-2020-26926",
                "trust": 0.8,
                "value": "Critical"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202010-358",
                "trust": 0.6,
                "value": "CRITICAL"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-012204"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202010-358"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-26926"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-26926"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Certain NETGEAR devices are affected by authentication bypass. This affects CBR40 before 2.5.0.10, RBK752 before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK852 before 3.2.10.11, RBR850 before 3.2.10.11, and RBS850 before 3.2.10.11. plural NETGEAR There is an authentication vulnerability in the device.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2020-26926"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-012204"
          }
        ],
        "trust": 1.62
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2020-26926",
            "trust": 2.4
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-012204",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202010-358",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-012204"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202010-358"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-26926"
          }
        ]
      },
      "id": "VAR-202010-0916",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "VARIoT devices database",
            "id": null
          }
        ],
        "trust": 0.14124016
      },
      "last_update_date": "2024-11-23T22:54:59.492000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Security\u00a0Advisory\u00a0for\u00a0Authentication\u00a0Bypass\u00a0on\u00a0Some\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0028",
            "trust": 0.8,
            "url": "https://kb.netgear.com/000062326/Security-Advisory-for-Authentication-Bypass-on-Some-WiFi-Systems-PSV-2020-0028"
          },
          {
            "title": "Multiple  NETGEAR Product access control error vulnerability fixes",
            "trust": 0.6,
            "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=129650"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-012204"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202010-358"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "NVD-CWE-noinfo",
            "trust": 1.0
          },
          {
            "problemtype": "Improper authentication (CWE-287) [NVD Evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-012204"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-26926"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.6,
            "url": "https://kb.netgear.com/000062326/security-advisory-for-authentication-bypass-on-some-wifi-systems-psv-2020-0028"
          },
          {
            "trust": 1.4,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2020-26926"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-012204"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202010-358"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-26926"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-012204"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202010-358"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-26926"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2021-04-27T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2020-012204"
          },
          {
            "date": "2020-10-09T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202010-358"
          },
          {
            "date": "2020-10-09T07:15:18.247000",
            "db": "NVD",
            "id": "CVE-2020-26926"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2021-04-27T05:37:00",
            "db": "JVNDB",
            "id": "JVNDB-2020-012204"
          },
          {
            "date": "2020-10-21T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202010-358"
          },
          {
            "date": "2024-11-21T05:20:30.790000",
            "db": "NVD",
            "id": "CVE-2020-26926"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote or local",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202010-358"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "plural \u00a0NETGEAR\u00a0 Authentication vulnerability in device",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-012204"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "authorization issue",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202010-358"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202112-2280

    Vulnerability from variot - Updated: 2024-11-23 22:54

    Certain NETGEAR devices are affected by stored XSS. This affects RAX200 before 1.0.3.106, MR60 before 1.0.6.110, RAX20 before 1.0.2.82, RAX45 before 1.0.2.72, RAX80 before 1.0.3.106, MS60 before 1.0.6.110, RAX15 before 1.0.2.82, RAX50 before 1.0.2.72, RAX75 before 1.0.3.106, RBR750 before 3.2.16.6, RBR850 before 3.2.16.6, RBS750 before 3.2.16.6, RBS850 before 3.2.16.6, RBK752 before 3.2.16.6, and RBK852 before 3.2.16.6. plural NETGEAR A cross-site scripting vulnerability exists in the device.Information may be obtained and information may be tampered with. This affects RAX200 prior to 1.0.3.106, MR60 prior to 1.0.6.110, RAX20 prior to 1.0.2.82, RAX45 prior to 1.0.2.72, RAX80 prior to 1.0.3.106, MS60 prior to 1.0.6.110, RAX15 prior to 1.0.2.82, RAX50 prior to 1.0.2.72, RAX75 prior to 1.0.3.106, RBR750 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBS850 prior to 3.2.16.6, RBK752 prior to 3.2.16.6, and RBK852 prior to 3.2.16.6

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202112-2280",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "rax45",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.2.72"
          },
          {
            "model": "rbk752",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.16.6"
          },
          {
            "model": "rax15",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.2.82"
          },
          {
            "model": "rax75",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.3.106"
          },
          {
            "model": "rbs750",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.16.6"
          },
          {
            "model": "rax20",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.2.82"
          },
          {
            "model": "rbr850",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.16.6"
          },
          {
            "model": "mr60",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.6.110"
          },
          {
            "model": "rbr750",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.16.6"
          },
          {
            "model": "rbk852",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.16.6"
          },
          {
            "model": "rax50",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.2.72"
          },
          {
            "model": "rax200",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.3.106"
          },
          {
            "model": "rbs850",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "3.2.16.6"
          },
          {
            "model": "ms60",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.6.110"
          },
          {
            "model": "rax80",
            "scope": "lt",
            "trust": 1.0,
            "vendor": "netgear",
            "version": "1.0.3.106"
          },
          {
            "model": "rax15",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rax45",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rax80",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rbr750",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rax50",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rax75",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rax20",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "mr60",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "ms60",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          },
          {
            "model": "rax200",
            "scope": null,
            "trust": 0.8,
            "vendor": "\u30cd\u30c3\u30c8\u30ae\u30a2",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-017170"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45669"
          }
        ]
      },
      "cve": "CVE-2021-45669",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "MEDIUM",
                "accessVector": "NETWORK",
                "authentication": "SINGLE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "NONE",
                "baseScore": 3.5,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 6.8,
                "id": "CVE-2021-45669",
                "impactScore": 2.9,
                "integrityImpact": "PARTIAL",
                "severity": "LOW",
                "trust": 1.9,
                "vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "NONE",
                "baseScore": 4.8,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "exploitabilityScore": 1.7,
                "id": "CVE-2021-45669",
                "impactScore": 2.7,
                "integrityImpact": "LOW",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "trust": 1.0,
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
                "version": "3.1"
              },
              {
                "attackComplexity": "HIGH",
                "attackVector": "ADJACENT",
                "author": "cve@mitre.org",
                "availabilityImpact": "NONE",
                "baseScore": 3.7,
                "baseSeverity": "LOW",
                "confidentialityImpact": "LOW",
                "exploitabilityScore": 0.7,
                "id": "CVE-2021-45669",
                "impactScore": 2.7,
                "integrityImpact": "LOW",
                "privilegesRequired": "HIGH",
                "scope": "CHANGED",
                "trust": 1.0,
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:A/AC:H/PR:H/UI:R/S:C/C:L/I:L/A:N",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "None",
                "baseScore": 4.8,
                "baseSeverity": "Medium",
                "confidentialityImpact": "Low",
                "exploitabilityScore": null,
                "id": "CVE-2021-45669",
                "impactScore": null,
                "integrityImpact": "Low",
                "privilegesRequired": "High",
                "scope": "Changed",
                "trust": 0.8,
                "userInteraction": "Required",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2021-45669",
                "trust": 1.0,
                "value": "MEDIUM"
              },
              {
                "author": "cve@mitre.org",
                "id": "CVE-2021-45669",
                "trust": 1.0,
                "value": "LOW"
              },
              {
                "author": "NVD",
                "id": "CVE-2021-45669",
                "trust": 0.8,
                "value": "Medium"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202112-2470",
                "trust": 0.6,
                "value": "MEDIUM"
              },
              {
                "author": "VULMON",
                "id": "CVE-2021-45669",
                "trust": 0.1,
                "value": "LOW"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "VULMON",
            "id": "CVE-2021-45669"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-017170"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2470"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45669"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45669"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Certain NETGEAR devices are affected by stored XSS. This affects RAX200 before 1.0.3.106, MR60 before 1.0.6.110, RAX20 before 1.0.2.82, RAX45 before 1.0.2.72, RAX80 before 1.0.3.106, MS60 before 1.0.6.110, RAX15 before 1.0.2.82, RAX50 before 1.0.2.72, RAX75 before 1.0.3.106, RBR750 before 3.2.16.6, RBR850 before 3.2.16.6, RBS750 before 3.2.16.6, RBS850 before 3.2.16.6, RBK752 before 3.2.16.6, and RBK852 before 3.2.16.6. plural NETGEAR A cross-site scripting vulnerability exists in the device.Information may be obtained and information may be tampered with. This affects RAX200 prior to 1.0.3.106, MR60 prior to 1.0.6.110, RAX20 prior to 1.0.2.82, RAX45 prior to 1.0.2.72, RAX80 prior to 1.0.3.106, MS60 prior to 1.0.6.110, RAX15 prior to 1.0.2.82, RAX50 prior to 1.0.2.72, RAX75 prior to 1.0.3.106, RBR750 prior to 3.2.16.6, RBR850 prior to 3.2.16.6, RBS750 prior to 3.2.16.6, RBS850 prior to 3.2.16.6, RBK752 prior to 3.2.16.6, and RBK852 prior to 3.2.16.6",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2021-45669"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-017170"
          },
          {
            "db": "VULMON",
            "id": "CVE-2021-45669"
          }
        ],
        "trust": 1.71
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2021-45669",
            "trust": 3.3
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-017170",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2470",
            "trust": 0.6
          },
          {
            "db": "VULMON",
            "id": "CVE-2021-45669",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "VULMON",
            "id": "CVE-2021-45669"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-017170"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2470"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45669"
          }
        ]
      },
      "id": "VAR-202112-2280",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "VARIoT devices database",
            "id": null
          }
        ],
        "trust": 0.14124016
      },
      "last_update_date": "2024-11-23T22:54:44.967000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Security\u00a0Advisory\u00a0for\u00a0Stored\u00a0Cross\u00a0Site\u00a0Scripting\u00a0on\u00a0Some\u00a0Routers\u00a0and\u00a0WiFi\u00a0Systems,\u00a0PSV-2020-0210",
            "trust": 0.8,
            "url": "https://kb.netgear.com/000064478/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-Routers-and-WiFi-Systems-PSV-2020-0210"
          },
          {
            "title": "Netgear RBR750  and NETGEAR Security vulnerabilities",
            "trust": 0.6,
            "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=175895"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-017170"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2470"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-79",
            "trust": 1.0
          },
          {
            "problemtype": "Cross-site scripting (CWE-79) [NVD evaluation ]",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-017170"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45669"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.7,
            "url": "https://kb.netgear.com/000064478/security-advisory-for-stored-cross-site-scripting-on-some-routers-and-wifi-systems-psv-2020-0210"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2021-45669"
          },
          {
            "trust": 0.1,
            "url": "https://cwe.mitre.org/data/definitions/79.html"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov"
          }
        ],
        "sources": [
          {
            "db": "VULMON",
            "id": "CVE-2021-45669"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-017170"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2470"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45669"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "VULMON",
            "id": "CVE-2021-45669"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-017170"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2470"
          },
          {
            "db": "NVD",
            "id": "CVE-2021-45669"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2021-12-26T00:00:00",
            "db": "VULMON",
            "id": "CVE-2021-45669"
          },
          {
            "date": "2023-01-06T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2021-017170"
          },
          {
            "date": "2021-12-26T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202112-2470"
          },
          {
            "date": "2021-12-26T01:15:20.960000",
            "db": "NVD",
            "id": "CVE-2021-45669"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2022-01-06T00:00:00",
            "db": "VULMON",
            "id": "CVE-2021-45669"
          },
          {
            "date": "2023-01-06T05:15:00",
            "db": "JVNDB",
            "id": "JVNDB-2021-017170"
          },
          {
            "date": "2022-01-07T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202112-2470"
          },
          {
            "date": "2024-11-21T06:32:50.190000",
            "db": "NVD",
            "id": "CVE-2021-45669"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2470"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "plural \u00a0NETGEAR\u00a0 Cross-site scripting vulnerabilities in devices",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2021-017170"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "XSS",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202112-2470"
          }
        ],
        "trust": 0.6
      }
    }