Search
Find a vulnerability
Search criteria
10 vulnerabilities found for PowerSYSTEM Center 2024 by Subnet Solutions
CVE-2026-63774 (GCVE-0-2026-63774)
Vulnerability from nvd – Published: 2026-11-06 00:05 – Updated: 2026-11-10 13:59
VLAI
EPSS
VEX
Title
Subnet Solutions PowerSYSTEM Center SQL Injection
Summary
Insufficient input validation in the PowerSYSTEM Center report designer allows an authenticated user to execute unauthorized SQL commands.
Severity
9 (Critical)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-11-10 13:59 UTC
CWE
Assigner
References
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Subnet Solutions | PowerSYSTEM Center 2024 |
Affected:
6.0.x , ≤ 6.2.x
(custom)
Unaffected: PowerSYSTEM Center 2026 Update 1.1 |
|
| Subnet Solutions | PowerSYSTEM Center 2026 |
Affected:
7.0.x , ≤ 7.1.x
(custom)
Unaffected: Update 1.1 |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-63774",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-11-10T13:59:40.732181Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-11-10T13:59:58.965Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerSYSTEM Center 2024",
"vendor": "Subnet Solutions",
"versions": [
{
"lessThanOrEqual": "6.2.x",
"status": "affected",
"version": "6.0.x",
"versionType": "custom"
},
{
"status": "unaffected",
"version": "PowerSYSTEM Center 2026 Update 1.1"
}
]
},
{
"defaultStatus": "unaffected",
"product": "PowerSYSTEM Center 2026",
"vendor": "Subnet Solutions",
"versions": [
{
"lessThanOrEqual": "7.1.x",
"status": "affected",
"version": "7.0.x",
"versionType": "custom"
},
{
"status": "unaffected",
"version": "Update 1.1"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Chinmay Patel of Digital Boundary Group reported this vulnerability to Subnet Solutions."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Insufficient input validation in the PowerSYSTEM Center report designer allows an authenticated user to execute unauthorized SQL commands."
}
],
"value": "Insufficient input validation in the PowerSYSTEM Center report designer allows an authenticated user to execute unauthorized SQL commands."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "ADJACENT",
"baseScore": 9.4,
"baseSeverity": "CRITICAL",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "HIGH",
"subIntegrityImpact": "HIGH",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-89",
"description": "CWE-89",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-11-06T00:05:00.309Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-307-01"
},
{
"url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-307-01.json"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "For users who are currently using PowerSYSTEM Center 2024, Subnet Solutions recommends users upgrade to PowerSYSTEM Center 2026 Update 1.1. For assistance in upgrading, users should contact the Subnet Solutions System Integration team or customer support team at (403) 270-8885 or by email at support@subnet.com.\u0026nbsp;"
}
],
"value": "For users who are currently using PowerSYSTEM Center 2024, Subnet Solutions recommends users upgrade to PowerSYSTEM Center 2026 Update 1.1. For assistance in upgrading, users should contact the Subnet Solutions System Integration team or customer support team at (403) 270-8885 or by email at support@subnet.com."
},
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Subnet Solutions recommends users update to PowerSYSTEM Center 2026 Update 1.1. For assistance in upgrading, users should contact the Subnet Solutions System Integration team or customer support team at (403) 270-8885 or by email at support@subnet.com.\u0026nbsp;"
}
],
"value": "Subnet Solutions recommends users update to PowerSYSTEM Center 2026 Update 1.1. For assistance in upgrading, users should contact the Subnet Solutions System Integration team or customer support team at (403) 270-8885 or by email at support@subnet.com."
}
],
"source": {
"advisory": "ICSA-26-307-01",
"discovery": "EXTERNAL"
},
"title": "Subnet Solutions PowerSYSTEM Center SQL Injection",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "If unable to update to the latest version, Subnet Solutions recommends users monitor user activity records to ensure users are following acceptable usage policies of the application. Subnet Solutions also recommends disabling PowerSYSTEM Center Client Access Server users\u0027 ability to access the browser\u0027s F12 Developer Tools."
}
],
"value": "If unable to update to the latest version, Subnet Solutions recommends users monitor user activity records to ensure users are following acceptable usage policies of the application. Subnet Solutions also recommends disabling PowerSYSTEM Center Client Access Server users\u0027 ability to access the browser\u0027s F12 Developer Tools."
}
],
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2026-63774",
"datePublished": "2026-11-06T00:05:00.309Z",
"dateReserved": "2026-07-27T21:24:52.067Z",
"dateUpdated": "2026-11-10T13:59:58.965Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-63017 (GCVE-0-2026-63017)
Vulnerability from nvd – Published: 2026-11-06 00:01 – Updated: 2026-11-10 14:00
VLAI
EPSS
VEX
Title
Subnet Solutions PowerSYSTEM Center Incorrect Authorization
Summary
Incorrect authorization in PowerSYSTEM Center allows a low-privileged, authenticated user to access resources normally limited to administrators.
Severity
9 (Critical)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-11-10 14:00 UTC
CWE
Assigner
References
Impacted products
3 products
| Vendor | Product | Version | |
|---|---|---|---|
| Subnet Solutions | PowerSYSTEM Center 2020 |
Affected:
0 , ≤ 5.29.x
(custom)
Unaffected: Update 30 |
|
| Subnet Solutions | PowerSYSTEM Center 2024 |
Affected:
6.0.x , ≤ 6.2.x
(custom)
Unaffected: PowerSYSTEM Center 2026 Update 1.1 |
|
| Subnet Solutions | PowerSYSTEM Center 2026 |
Affected:
7.0.x , ≤ 7.1.x
(custom)
Unaffected: Update 1.1 |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-63017",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-11-10T14:00:30.165612Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-11-10T14:00:41.665Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerSYSTEM Center 2020",
"vendor": "Subnet Solutions",
"versions": [
{
"lessThanOrEqual": "5.29.x",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"status": "unaffected",
"version": "Update 30"
}
]
},
{
"defaultStatus": "unaffected",
"product": "PowerSYSTEM Center 2024",
"vendor": "Subnet Solutions",
"versions": [
{
"lessThanOrEqual": "6.2.x",
"status": "affected",
"version": "6.0.x",
"versionType": "custom"
},
{
"status": "unaffected",
"version": "PowerSYSTEM Center 2026 Update 1.1"
}
]
},
{
"defaultStatus": "unaffected",
"product": "PowerSYSTEM Center 2026",
"vendor": "Subnet Solutions",
"versions": [
{
"lessThanOrEqual": "7.1.x",
"status": "affected",
"version": "7.0.x",
"versionType": "custom"
},
{
"status": "unaffected",
"version": "Update 1.1"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Chinmay Patel of Digital Boundary Group reported this vulnerability to Subnet Solutions."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Incorrect authorization in PowerSYSTEM Center allows a low-privileged, authenticated user to access resources normally limited to administrators."
}
],
"value": "Incorrect authorization in PowerSYSTEM Center allows a low-privileged, authenticated user to access resources normally limited to administrators."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "ADJACENT",
"baseScore": 9.4,
"baseSeverity": "CRITICAL",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "HIGH",
"subIntegrityImpact": "HIGH",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-863",
"description": "CWE-863",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-11-06T00:06:42.203Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-307-01"
},
{
"url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-307-01.json"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "For users who are currently using PowerSYSTEM Center 2024, Subnet Solutions recommends users upgrade to PowerSYSTEM Center 2026 Update 1.1. For assistance in upgrading, users should contact the Subnet Solutions System Integration team or customer support team at (403) 270-8885 or by email at support@subnet.com.\u0026nbsp;"
}
],
"value": "For users who are currently using PowerSYSTEM Center 2024, Subnet Solutions recommends users upgrade to PowerSYSTEM Center 2026 Update 1.1. For assistance in upgrading, users should contact the Subnet Solutions System Integration team or customer support team at (403) 270-8885 or by email at support@subnet.com."
},
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Subnet Solutions recommends users update to PowerSYSTEM Center 2020 Update 30. For assistance in upgrading, users should contact the Subnet Solutions System Integration team or customer support team at (403) 270-8885 or by email at support@subnet.com.\u0026nbsp;"
}
],
"value": "Subnet Solutions recommends users update to PowerSYSTEM Center 2020 Update 30. For assistance in upgrading, users should contact the Subnet Solutions System Integration team or customer support team at (403) 270-8885 or by email at support@subnet.com."
},
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Subnet Solutions recommends users update to PowerSYSTEM Center 2026 Update 1.1. For assistance in upgrading, users should contact the Subnet Solutions System Integration team or customer support team at (403) 270-8885 or by email at support@subnet.com.\u0026nbsp;"
}
],
"value": "Subnet Solutions recommends users update to PowerSYSTEM Center 2026 Update 1.1. For assistance in upgrading, users should contact the Subnet Solutions System Integration team or customer support team at (403) 270-8885 or by email at support@subnet.com."
}
],
"source": {
"advisory": "ICSA-26-307-01",
"discovery": "EXTERNAL"
},
"title": "Subnet Solutions PowerSYSTEM Center Incorrect Authorization",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "If unable to update to the latest version, Subnet Solutions recommends users monitor user activity records to ensure users are following acceptable usage policies of the application. Subnet Solutions also recommends disabling PowerSYSTEM Center Client Access Server users\u0027 ability to access the browser\u0027s F12 Developer Tools."
}
],
"value": "If unable to update to the latest version, Subnet Solutions recommends users monitor user activity records to ensure users are following acceptable usage policies of the application. Subnet Solutions also recommends disabling PowerSYSTEM Center Client Access Server users\u0027 ability to access the browser\u0027s F12 Developer Tools."
}
],
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2026-63017",
"datePublished": "2026-11-06T00:01:21.625Z",
"dateReserved": "2026-07-27T21:24:52.071Z",
"dateUpdated": "2026-11-10T14:00:41.665Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-35555 (GCVE-0-2026-35555)
Vulnerability from nvd – Published: 2026-05-12 20:48 – Updated: 2026-05-13 00:20
VLAI
EPSS
VEX
Title
Subnet Solutions PowerSYSTEM Center Incorrect Authorization
Summary
PowerSYSTEM Center feature for device project groups allows an authenticated user with limited permissions to perform an unauthorized deletion of project groups.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-05-13 00:19 UTC
CWE
- CWE-863 - Incorrect Authorization
Assigner
References
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Subnet Solutions | PowerSYSTEM Center 2024 |
Affected:
6.0.x , ≤ 6.1.x
(custom)
|
|
| Subnet Solutions | PowerSYSTEM Center 2026 |
Affected:
7.0.x
(custom)
|
Date Public
2026-05-13 05:00
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-35555",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-05-13T00:19:55.864884Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-05-13T00:20:11.420Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerSYSTEM Center 2024",
"vendor": "Subnet Solutions",
"versions": [
{
"lessThanOrEqual": "6.1.x",
"status": "affected",
"version": "6.0.x",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "PowerSYSTEM Center 2026",
"vendor": "Subnet Solutions",
"versions": [
{
"status": "affected",
"version": "7.0.x",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Kelly Stich of Subnet Solutions Inc. reported these vulnerabilities to CISA."
}
],
"datePublic": "2026-05-13T05:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "PowerSYSTEM Center feature for device project groups allows an authenticated user with limited permissions to perform an unauthorized deletion of project groups."
}
],
"value": "PowerSYSTEM Center feature for device project groups allows an authenticated user with limited permissions to perform an unauthorized deletion of project groups."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "ADJACENT",
"baseScore": 7,
"baseSeverity": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:L/UI:N/VC:N/VI:H/VA:L/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "LOW",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "LOW",
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:L",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-863",
"description": "CWE-863 Incorrect Authorization",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-05-12T20:48:13.076Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-132-02"
},
{
"url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-132-02.json"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Subnet Solutions recommends users update to the latest version of PowerSYSTEM Center PSC 2020 Update 29, PSC 2024 Update 2, and PSC 2026 GA Hotfix.\n\u003cbr\u003e\n\u003cbr\u003eFor assistance in upgrading, users should contact a Subnet Solutions System Integration team member or customer support team at (403) 270-8885 or by email at [support@subnet.com](mailto:support@subnet.com).\n\u003cbr\u003e\n\u003cbr\u003eSubnet Solutions recommends users do the following in order to reduce risk:\n\u003cbr\u003e* Monitor user activity records to ensure users are following acceptable usage policies of the application.\n\u003cbr\u003e* Restrict access to Notification Settings to trusted Administrators Monitor \"Send from Address\" in settings and Activity Records.\n\u003cbr\u003e* Configure a notification rule that triggers in any bulk account export activity."
}
],
"value": "Subnet Solutions recommends users update to the latest version of PowerSYSTEM Center PSC 2020 Update 29, PSC 2024 Update 2, and PSC 2026 GA Hotfix.\n\n\n\nFor assistance in upgrading, users should contact a Subnet Solutions System Integration team member or customer support team at (403) 270-8885 or by email at [support@subnet.com](mailto:support@subnet.com).\n\n\n\nSubnet Solutions recommends users do the following in order to reduce risk:\n\n* Monitor user activity records to ensure users are following acceptable usage policies of the application.\n\n* Restrict access to Notification Settings to trusted Administrators Monitor \"Send from Address\" in settings and Activity Records.\n\n* Configure a notification rule that triggers in any bulk account export activity."
}
],
"source": {
"advisory": "ICSA-26-132-02",
"discovery": "INTERNAL"
},
"title": "Subnet Solutions PowerSYSTEM Center Incorrect Authorization",
"x_generator": {
"engine": "Vulnogram 1.0.2"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2026-35555",
"datePublished": "2026-05-12T20:48:13.076Z",
"dateReserved": "2026-04-16T14:05:42.152Z",
"dateUpdated": "2026-05-13T00:20:11.420Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-26289 (GCVE-0-2026-26289)
Vulnerability from nvd – Published: 2026-05-12 21:02 – Updated: 2026-05-13 00:19
VLAI
EPSS
VEX
Title
Subnet Solutions PowerSYSTEM Center Incorrect Authorization
Summary
PowerSYSTEM Center REST API endpoint for device account export allows an authenticated user with limited permissions to expose sensitive information normally restricted to administrative permissions only.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-05-13 00:19 UTC
CWE
- CWE-863 - Incorrect Authorization
Assigner
References
Impacted products
3 products
| Vendor | Product | Version | |
|---|---|---|---|
| Subnet Solutions | PowerSYSTEM Center 2020 |
Affected:
5.8.x , ≤ 5.28.x
(custom)
|
|
| Subnet Solutions | PowerSYSTEM Center 2024 |
Affected:
6.0.x , ≤ 6.1.x
(custom)
|
|
| Subnet Solutions | PowerSYSTEM Center 2026 |
Affected:
7.0.x
|
Date Public
2026-05-13 05:00
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-26289",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-05-13T00:19:06.419342Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-05-13T00:19:14.634Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerSYSTEM Center 2020",
"vendor": "Subnet Solutions",
"versions": [
{
"lessThanOrEqual": "5.28.x",
"status": "affected",
"version": "5.8.x",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "PowerSYSTEM Center 2024",
"vendor": "Subnet Solutions",
"versions": [
{
"lessThanOrEqual": "6.1.x",
"status": "affected",
"version": "6.0.x",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "PowerSYSTEM Center 2026",
"vendor": "Subnet Solutions",
"versions": [
{
"status": "affected",
"version": "7.0.x"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Kelly Stich of Subnet Solutions Inc. reported these vulnerabilities to CISA."
}
],
"datePublic": "2026-05-13T05:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "PowerSYSTEM Center REST API endpoint for device account export allows an authenticated user with limited permissions to expose sensitive information normally restricted to administrative permissions only."
}
],
"value": "PowerSYSTEM Center REST API endpoint for device account export allows an authenticated user with limited permissions to expose sensitive information normally restricted to administrative permissions only."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "ADJACENT",
"baseScore": 8.4,
"baseSeverity": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "HIGH",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:L/UI:N/VC:H/VI:L/VA:L/SC:N/SI:H/SA:H",
"version": "4.0",
"vulnAvailabilityImpact": "LOW",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "LOW",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "LOW",
"baseScore": 8.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:C/C:H/I:L/A:L",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-863",
"description": "CWE-863 Incorrect Authorization",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-05-12T21:02:42.509Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-132-02"
},
{
"url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-132-02.json"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Subnet Solutions recommends users update to the latest version of PowerSYSTEM Center PSC 2020 Update 29, PSC 2024 Update 2, and PSC 2026 GA Hotfix.\n\u003cbr\u003e\n\u003cbr\u003eFor assistance in upgrading, users should contact a Subnet Solutions System Integration team member or customer support team at (403) 270-8885 or by email at [support@subnet.com](mailto:support@subnet.com).\n\u003cbr\u003e\n\u003cbr\u003eSubnet Solutions recommends users do the following in order to reduce risk:\n\u003cbr\u003e* Monitor user activity records to ensure users are following acceptable usage policies of the application.\n\u003cbr\u003e* Restrict access to Notification Settings to trusted Administrators Monitor \"Send from Address\" in settings and Activity Records.\n\u003cbr\u003e* Configure a notification rule that triggers in any bulk account export activity."
}
],
"value": "Subnet Solutions recommends users update to the latest version of PowerSYSTEM Center PSC 2020 Update 29, PSC 2024 Update 2, and PSC 2026 GA Hotfix.\n\n\n\nFor assistance in upgrading, users should contact a Subnet Solutions System Integration team member or customer support team at (403) 270-8885 or by email at [support@subnet.com](mailto:support@subnet.com).\n\n\n\nSubnet Solutions recommends users do the following in order to reduce risk:\n\n* Monitor user activity records to ensure users are following acceptable usage policies of the application.\n\n* Restrict access to Notification Settings to trusted Administrators Monitor \"Send from Address\" in settings and Activity Records.\n\n* Configure a notification rule that triggers in any bulk account export activity."
}
],
"source": {
"advisory": "ICSA-26-132-02",
"discovery": "INTERNAL"
},
"title": "Subnet Solutions PowerSYSTEM Center Incorrect Authorization",
"x_generator": {
"engine": "Vulnogram 1.0.2"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2026-26289",
"datePublished": "2026-05-12T21:02:42.509Z",
"dateReserved": "2026-04-16T14:05:42.127Z",
"dateUpdated": "2026-05-13T00:19:14.634Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-35504 (GCVE-0-2026-35504)
Vulnerability from nvd – Published: 2026-05-12 20:19 – Updated: 2026-05-12 21:12
VLAI
EPSS
VEX
Title
Subnet Solutions PowerSYSTEM Center CRLF injection
Summary
PowerSYSTEM Center email notification service is affected by a CRLF injection vulnerability when using SMTPS communication.
Severity
5.5 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-05-12 21:01 UTC
CWE
- CWE-93 - Improper neutralization of CRLF sequences ('CRLF injection')
Assigner
References
Impacted products
3 products
| Vendor | Product | Version | |
|---|---|---|---|
| Subnet Solutions | PowerSYSTEM Center 2020 |
Affected:
0 , ≤ 5.28.x
(custom)
|
|
| Subnet Solutions | PowerSYSTEM Center 2024 |
Affected:
6.0.x , ≤ 6.1.x
(custom)
|
|
| Subnet Solutions | PowerSYSTEM Center 2026 |
Affected:
7.0.x
|
Date Public
2026-05-13 05:00
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-35504",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-05-12T21:01:40.300358Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-05-12T21:12:55.834Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerSYSTEM Center 2020",
"vendor": "Subnet Solutions",
"versions": [
{
"lessThanOrEqual": "5.28.x",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "PowerSYSTEM Center 2024",
"vendor": "Subnet Solutions",
"versions": [
{
"lessThanOrEqual": "6.1.x",
"status": "affected",
"version": "6.0.x",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "PowerSYSTEM Center 2026",
"vendor": "Subnet Solutions",
"versions": [
{
"status": "affected",
"version": "7.0.x"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Kelly Stich of Subnet Solutions Inc. reported these vulnerabilities to CISA."
}
],
"datePublic": "2026-05-13T05:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "PowerSYSTEM Center email notification service is affected by a CRLF injection vulnerability when using SMTPS communication."
}
],
"value": "PowerSYSTEM Center email notification service is affected by a CRLF injection vulnerability when using SMTPS communication."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "ADJACENT",
"baseScore": 5.1,
"baseSeverity": "MEDIUM",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "LOW",
"vulnConfidentialityImpact": "LOW",
"vulnIntegrityImpact": "LOW",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "LOW",
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-93",
"description": "CWE-93 Improper neutralization of CRLF sequences (\u0027CRLF injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-05-12T20:45:23.739Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-132-02"
},
{
"url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-132-02.json"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Subnet Solutions recommends users update to the latest version of PowerSYSTEM Center PSC 2020 Update 29, PSC 2024 Update 2, and PSC 2026 GA Hotfix.\n\u003cbr\u003e\n\u003cbr\u003eFor assistance in upgrading, users should contact a Subnet Solutions System Integration team member or customer support team at (403) 270-8885 or by email at [support@subnet.com](mailto:support@subnet.com).\n\u003cbr\u003e\n\u003cbr\u003eSubnet Solutions recommends users do the following in order to reduce risk:\n\u003cbr\u003e* Monitor user activity records to ensure users are following acceptable usage policies of the application.\n\u003cbr\u003e* Restrict access to Notification Settings to trusted Administrators Monitor \"Send from Address\" in settings and Activity Records.\n\u003cbr\u003e* Configure a notification rule that triggers in any bulk account export activity."
}
],
"value": "Subnet Solutions recommends users update to the latest version of PowerSYSTEM Center PSC 2020 Update 29, PSC 2024 Update 2, and PSC 2026 GA Hotfix.\n\n\n\nFor assistance in upgrading, users should contact a Subnet Solutions System Integration team member or customer support team at (403) 270-8885 or by email at [support@subnet.com](mailto:support@subnet.com).\n\n\n\nSubnet Solutions recommends users do the following in order to reduce risk:\n\n* Monitor user activity records to ensure users are following acceptable usage policies of the application.\n\n* Restrict access to Notification Settings to trusted Administrators Monitor \"Send from Address\" in settings and Activity Records.\n\n* Configure a notification rule that triggers in any bulk account export activity."
}
],
"source": {
"advisory": "ICSA-26-132-02",
"discovery": "INTERNAL"
},
"title": "Subnet Solutions PowerSYSTEM Center CRLF injection",
"x_generator": {
"engine": "Vulnogram 1.0.2"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2026-35504",
"datePublished": "2026-05-12T20:19:38.126Z",
"dateReserved": "2026-04-16T14:05:42.158Z",
"dateUpdated": "2026-05-12T21:12:55.834Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-63774 (GCVE-0-2026-63774)
Vulnerability from cvelistv5 – Published: 2026-11-06 00:05 – Updated: 2026-11-10 13:59
VLAI
EPSS
VEX
Title
Subnet Solutions PowerSYSTEM Center SQL Injection
Summary
Insufficient input validation in the PowerSYSTEM Center report designer allows an authenticated user to execute unauthorized SQL commands.
Severity
9 (Critical)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-11-10 13:59 UTC
CWE
Assigner
References
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Subnet Solutions | PowerSYSTEM Center 2024 |
Affected:
6.0.x , ≤ 6.2.x
(custom)
Unaffected: PowerSYSTEM Center 2026 Update 1.1 |
|
| Subnet Solutions | PowerSYSTEM Center 2026 |
Affected:
7.0.x , ≤ 7.1.x
(custom)
Unaffected: Update 1.1 |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-63774",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-11-10T13:59:40.732181Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-11-10T13:59:58.965Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerSYSTEM Center 2024",
"vendor": "Subnet Solutions",
"versions": [
{
"lessThanOrEqual": "6.2.x",
"status": "affected",
"version": "6.0.x",
"versionType": "custom"
},
{
"status": "unaffected",
"version": "PowerSYSTEM Center 2026 Update 1.1"
}
]
},
{
"defaultStatus": "unaffected",
"product": "PowerSYSTEM Center 2026",
"vendor": "Subnet Solutions",
"versions": [
{
"lessThanOrEqual": "7.1.x",
"status": "affected",
"version": "7.0.x",
"versionType": "custom"
},
{
"status": "unaffected",
"version": "Update 1.1"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Chinmay Patel of Digital Boundary Group reported this vulnerability to Subnet Solutions."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Insufficient input validation in the PowerSYSTEM Center report designer allows an authenticated user to execute unauthorized SQL commands."
}
],
"value": "Insufficient input validation in the PowerSYSTEM Center report designer allows an authenticated user to execute unauthorized SQL commands."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "ADJACENT",
"baseScore": 9.4,
"baseSeverity": "CRITICAL",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "HIGH",
"subIntegrityImpact": "HIGH",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-89",
"description": "CWE-89",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-11-06T00:05:00.309Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-307-01"
},
{
"url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-307-01.json"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "For users who are currently using PowerSYSTEM Center 2024, Subnet Solutions recommends users upgrade to PowerSYSTEM Center 2026 Update 1.1. For assistance in upgrading, users should contact the Subnet Solutions System Integration team or customer support team at (403) 270-8885 or by email at support@subnet.com.\u0026nbsp;"
}
],
"value": "For users who are currently using PowerSYSTEM Center 2024, Subnet Solutions recommends users upgrade to PowerSYSTEM Center 2026 Update 1.1. For assistance in upgrading, users should contact the Subnet Solutions System Integration team or customer support team at (403) 270-8885 or by email at support@subnet.com."
},
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Subnet Solutions recommends users update to PowerSYSTEM Center 2026 Update 1.1. For assistance in upgrading, users should contact the Subnet Solutions System Integration team or customer support team at (403) 270-8885 or by email at support@subnet.com.\u0026nbsp;"
}
],
"value": "Subnet Solutions recommends users update to PowerSYSTEM Center 2026 Update 1.1. For assistance in upgrading, users should contact the Subnet Solutions System Integration team or customer support team at (403) 270-8885 or by email at support@subnet.com."
}
],
"source": {
"advisory": "ICSA-26-307-01",
"discovery": "EXTERNAL"
},
"title": "Subnet Solutions PowerSYSTEM Center SQL Injection",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "If unable to update to the latest version, Subnet Solutions recommends users monitor user activity records to ensure users are following acceptable usage policies of the application. Subnet Solutions also recommends disabling PowerSYSTEM Center Client Access Server users\u0027 ability to access the browser\u0027s F12 Developer Tools."
}
],
"value": "If unable to update to the latest version, Subnet Solutions recommends users monitor user activity records to ensure users are following acceptable usage policies of the application. Subnet Solutions also recommends disabling PowerSYSTEM Center Client Access Server users\u0027 ability to access the browser\u0027s F12 Developer Tools."
}
],
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2026-63774",
"datePublished": "2026-11-06T00:05:00.309Z",
"dateReserved": "2026-07-27T21:24:52.067Z",
"dateUpdated": "2026-11-10T13:59:58.965Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-63017 (GCVE-0-2026-63017)
Vulnerability from cvelistv5 – Published: 2026-11-06 00:01 – Updated: 2026-11-10 14:00
VLAI
EPSS
VEX
Title
Subnet Solutions PowerSYSTEM Center Incorrect Authorization
Summary
Incorrect authorization in PowerSYSTEM Center allows a low-privileged, authenticated user to access resources normally limited to administrators.
Severity
9 (Critical)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-11-10 14:00 UTC
CWE
Assigner
References
Impacted products
3 products
| Vendor | Product | Version | |
|---|---|---|---|
| Subnet Solutions | PowerSYSTEM Center 2020 |
Affected:
0 , ≤ 5.29.x
(custom)
Unaffected: Update 30 |
|
| Subnet Solutions | PowerSYSTEM Center 2024 |
Affected:
6.0.x , ≤ 6.2.x
(custom)
Unaffected: PowerSYSTEM Center 2026 Update 1.1 |
|
| Subnet Solutions | PowerSYSTEM Center 2026 |
Affected:
7.0.x , ≤ 7.1.x
(custom)
Unaffected: Update 1.1 |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-63017",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-11-10T14:00:30.165612Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-11-10T14:00:41.665Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerSYSTEM Center 2020",
"vendor": "Subnet Solutions",
"versions": [
{
"lessThanOrEqual": "5.29.x",
"status": "affected",
"version": "0",
"versionType": "custom"
},
{
"status": "unaffected",
"version": "Update 30"
}
]
},
{
"defaultStatus": "unaffected",
"product": "PowerSYSTEM Center 2024",
"vendor": "Subnet Solutions",
"versions": [
{
"lessThanOrEqual": "6.2.x",
"status": "affected",
"version": "6.0.x",
"versionType": "custom"
},
{
"status": "unaffected",
"version": "PowerSYSTEM Center 2026 Update 1.1"
}
]
},
{
"defaultStatus": "unaffected",
"product": "PowerSYSTEM Center 2026",
"vendor": "Subnet Solutions",
"versions": [
{
"lessThanOrEqual": "7.1.x",
"status": "affected",
"version": "7.0.x",
"versionType": "custom"
},
{
"status": "unaffected",
"version": "Update 1.1"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Chinmay Patel of Digital Boundary Group reported this vulnerability to Subnet Solutions."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Incorrect authorization in PowerSYSTEM Center allows a low-privileged, authenticated user to access resources normally limited to administrators."
}
],
"value": "Incorrect authorization in PowerSYSTEM Center allows a low-privileged, authenticated user to access resources normally limited to administrators."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "ADJACENT",
"baseScore": 9.4,
"baseSeverity": "CRITICAL",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "HIGH",
"subIntegrityImpact": "HIGH",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-863",
"description": "CWE-863",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-11-06T00:06:42.203Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-307-01"
},
{
"url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-307-01.json"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "For users who are currently using PowerSYSTEM Center 2024, Subnet Solutions recommends users upgrade to PowerSYSTEM Center 2026 Update 1.1. For assistance in upgrading, users should contact the Subnet Solutions System Integration team or customer support team at (403) 270-8885 or by email at support@subnet.com.\u0026nbsp;"
}
],
"value": "For users who are currently using PowerSYSTEM Center 2024, Subnet Solutions recommends users upgrade to PowerSYSTEM Center 2026 Update 1.1. For assistance in upgrading, users should contact the Subnet Solutions System Integration team or customer support team at (403) 270-8885 or by email at support@subnet.com."
},
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Subnet Solutions recommends users update to PowerSYSTEM Center 2020 Update 30. For assistance in upgrading, users should contact the Subnet Solutions System Integration team or customer support team at (403) 270-8885 or by email at support@subnet.com.\u0026nbsp;"
}
],
"value": "Subnet Solutions recommends users update to PowerSYSTEM Center 2020 Update 30. For assistance in upgrading, users should contact the Subnet Solutions System Integration team or customer support team at (403) 270-8885 or by email at support@subnet.com."
},
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Subnet Solutions recommends users update to PowerSYSTEM Center 2026 Update 1.1. For assistance in upgrading, users should contact the Subnet Solutions System Integration team or customer support team at (403) 270-8885 or by email at support@subnet.com.\u0026nbsp;"
}
],
"value": "Subnet Solutions recommends users update to PowerSYSTEM Center 2026 Update 1.1. For assistance in upgrading, users should contact the Subnet Solutions System Integration team or customer support team at (403) 270-8885 or by email at support@subnet.com."
}
],
"source": {
"advisory": "ICSA-26-307-01",
"discovery": "EXTERNAL"
},
"title": "Subnet Solutions PowerSYSTEM Center Incorrect Authorization",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "If unable to update to the latest version, Subnet Solutions recommends users monitor user activity records to ensure users are following acceptable usage policies of the application. Subnet Solutions also recommends disabling PowerSYSTEM Center Client Access Server users\u0027 ability to access the browser\u0027s F12 Developer Tools."
}
],
"value": "If unable to update to the latest version, Subnet Solutions recommends users monitor user activity records to ensure users are following acceptable usage policies of the application. Subnet Solutions also recommends disabling PowerSYSTEM Center Client Access Server users\u0027 ability to access the browser\u0027s F12 Developer Tools."
}
],
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2026-63017",
"datePublished": "2026-11-06T00:01:21.625Z",
"dateReserved": "2026-07-27T21:24:52.071Z",
"dateUpdated": "2026-11-10T14:00:41.665Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-26289 (GCVE-0-2026-26289)
Vulnerability from cvelistv5 – Published: 2026-05-12 21:02 – Updated: 2026-05-13 00:19
VLAI
EPSS
VEX
Title
Subnet Solutions PowerSYSTEM Center Incorrect Authorization
Summary
PowerSYSTEM Center REST API endpoint for device account export allows an authenticated user with limited permissions to expose sensitive information normally restricted to administrative permissions only.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-05-13 00:19 UTC
CWE
- CWE-863 - Incorrect Authorization
Assigner
References
Impacted products
3 products
| Vendor | Product | Version | |
|---|---|---|---|
| Subnet Solutions | PowerSYSTEM Center 2020 |
Affected:
5.8.x , ≤ 5.28.x
(custom)
|
|
| Subnet Solutions | PowerSYSTEM Center 2024 |
Affected:
6.0.x , ≤ 6.1.x
(custom)
|
|
| Subnet Solutions | PowerSYSTEM Center 2026 |
Affected:
7.0.x
|
Date Public
2026-05-13 05:00
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-26289",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-05-13T00:19:06.419342Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-05-13T00:19:14.634Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerSYSTEM Center 2020",
"vendor": "Subnet Solutions",
"versions": [
{
"lessThanOrEqual": "5.28.x",
"status": "affected",
"version": "5.8.x",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "PowerSYSTEM Center 2024",
"vendor": "Subnet Solutions",
"versions": [
{
"lessThanOrEqual": "6.1.x",
"status": "affected",
"version": "6.0.x",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "PowerSYSTEM Center 2026",
"vendor": "Subnet Solutions",
"versions": [
{
"status": "affected",
"version": "7.0.x"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Kelly Stich of Subnet Solutions Inc. reported these vulnerabilities to CISA."
}
],
"datePublic": "2026-05-13T05:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "PowerSYSTEM Center REST API endpoint for device account export allows an authenticated user with limited permissions to expose sensitive information normally restricted to administrative permissions only."
}
],
"value": "PowerSYSTEM Center REST API endpoint for device account export allows an authenticated user with limited permissions to expose sensitive information normally restricted to administrative permissions only."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "ADJACENT",
"baseScore": 8.4,
"baseSeverity": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "HIGH",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:L/UI:N/VC:H/VI:L/VA:L/SC:N/SI:H/SA:H",
"version": "4.0",
"vulnAvailabilityImpact": "LOW",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "LOW",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "LOW",
"baseScore": 8.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:C/C:H/I:L/A:L",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-863",
"description": "CWE-863 Incorrect Authorization",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-05-12T21:02:42.509Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-132-02"
},
{
"url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-132-02.json"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Subnet Solutions recommends users update to the latest version of PowerSYSTEM Center PSC 2020 Update 29, PSC 2024 Update 2, and PSC 2026 GA Hotfix.\n\u003cbr\u003e\n\u003cbr\u003eFor assistance in upgrading, users should contact a Subnet Solutions System Integration team member or customer support team at (403) 270-8885 or by email at [support@subnet.com](mailto:support@subnet.com).\n\u003cbr\u003e\n\u003cbr\u003eSubnet Solutions recommends users do the following in order to reduce risk:\n\u003cbr\u003e* Monitor user activity records to ensure users are following acceptable usage policies of the application.\n\u003cbr\u003e* Restrict access to Notification Settings to trusted Administrators Monitor \"Send from Address\" in settings and Activity Records.\n\u003cbr\u003e* Configure a notification rule that triggers in any bulk account export activity."
}
],
"value": "Subnet Solutions recommends users update to the latest version of PowerSYSTEM Center PSC 2020 Update 29, PSC 2024 Update 2, and PSC 2026 GA Hotfix.\n\n\n\nFor assistance in upgrading, users should contact a Subnet Solutions System Integration team member or customer support team at (403) 270-8885 or by email at [support@subnet.com](mailto:support@subnet.com).\n\n\n\nSubnet Solutions recommends users do the following in order to reduce risk:\n\n* Monitor user activity records to ensure users are following acceptable usage policies of the application.\n\n* Restrict access to Notification Settings to trusted Administrators Monitor \"Send from Address\" in settings and Activity Records.\n\n* Configure a notification rule that triggers in any bulk account export activity."
}
],
"source": {
"advisory": "ICSA-26-132-02",
"discovery": "INTERNAL"
},
"title": "Subnet Solutions PowerSYSTEM Center Incorrect Authorization",
"x_generator": {
"engine": "Vulnogram 1.0.2"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2026-26289",
"datePublished": "2026-05-12T21:02:42.509Z",
"dateReserved": "2026-04-16T14:05:42.127Z",
"dateUpdated": "2026-05-13T00:19:14.634Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-35555 (GCVE-0-2026-35555)
Vulnerability from cvelistv5 – Published: 2026-05-12 20:48 – Updated: 2026-05-13 00:20
VLAI
EPSS
VEX
Title
Subnet Solutions PowerSYSTEM Center Incorrect Authorization
Summary
PowerSYSTEM Center feature for device project groups allows an authenticated user with limited permissions to perform an unauthorized deletion of project groups.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-05-13 00:19 UTC
CWE
- CWE-863 - Incorrect Authorization
Assigner
References
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Subnet Solutions | PowerSYSTEM Center 2024 |
Affected:
6.0.x , ≤ 6.1.x
(custom)
|
|
| Subnet Solutions | PowerSYSTEM Center 2026 |
Affected:
7.0.x
(custom)
|
Date Public
2026-05-13 05:00
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-35555",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-05-13T00:19:55.864884Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-05-13T00:20:11.420Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerSYSTEM Center 2024",
"vendor": "Subnet Solutions",
"versions": [
{
"lessThanOrEqual": "6.1.x",
"status": "affected",
"version": "6.0.x",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "PowerSYSTEM Center 2026",
"vendor": "Subnet Solutions",
"versions": [
{
"status": "affected",
"version": "7.0.x",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Kelly Stich of Subnet Solutions Inc. reported these vulnerabilities to CISA."
}
],
"datePublic": "2026-05-13T05:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "PowerSYSTEM Center feature for device project groups allows an authenticated user with limited permissions to perform an unauthorized deletion of project groups."
}
],
"value": "PowerSYSTEM Center feature for device project groups allows an authenticated user with limited permissions to perform an unauthorized deletion of project groups."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "ADJACENT",
"baseScore": 7,
"baseSeverity": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:L/UI:N/VC:N/VI:H/VA:L/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "LOW",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "LOW",
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:L",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-863",
"description": "CWE-863 Incorrect Authorization",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-05-12T20:48:13.076Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-132-02"
},
{
"url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-132-02.json"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Subnet Solutions recommends users update to the latest version of PowerSYSTEM Center PSC 2020 Update 29, PSC 2024 Update 2, and PSC 2026 GA Hotfix.\n\u003cbr\u003e\n\u003cbr\u003eFor assistance in upgrading, users should contact a Subnet Solutions System Integration team member or customer support team at (403) 270-8885 or by email at [support@subnet.com](mailto:support@subnet.com).\n\u003cbr\u003e\n\u003cbr\u003eSubnet Solutions recommends users do the following in order to reduce risk:\n\u003cbr\u003e* Monitor user activity records to ensure users are following acceptable usage policies of the application.\n\u003cbr\u003e* Restrict access to Notification Settings to trusted Administrators Monitor \"Send from Address\" in settings and Activity Records.\n\u003cbr\u003e* Configure a notification rule that triggers in any bulk account export activity."
}
],
"value": "Subnet Solutions recommends users update to the latest version of PowerSYSTEM Center PSC 2020 Update 29, PSC 2024 Update 2, and PSC 2026 GA Hotfix.\n\n\n\nFor assistance in upgrading, users should contact a Subnet Solutions System Integration team member or customer support team at (403) 270-8885 or by email at [support@subnet.com](mailto:support@subnet.com).\n\n\n\nSubnet Solutions recommends users do the following in order to reduce risk:\n\n* Monitor user activity records to ensure users are following acceptable usage policies of the application.\n\n* Restrict access to Notification Settings to trusted Administrators Monitor \"Send from Address\" in settings and Activity Records.\n\n* Configure a notification rule that triggers in any bulk account export activity."
}
],
"source": {
"advisory": "ICSA-26-132-02",
"discovery": "INTERNAL"
},
"title": "Subnet Solutions PowerSYSTEM Center Incorrect Authorization",
"x_generator": {
"engine": "Vulnogram 1.0.2"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2026-35555",
"datePublished": "2026-05-12T20:48:13.076Z",
"dateReserved": "2026-04-16T14:05:42.152Z",
"dateUpdated": "2026-05-13T00:20:11.420Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-35504 (GCVE-0-2026-35504)
Vulnerability from cvelistv5 – Published: 2026-05-12 20:19 – Updated: 2026-05-12 21:12
VLAI
EPSS
VEX
Title
Subnet Solutions PowerSYSTEM Center CRLF injection
Summary
PowerSYSTEM Center email notification service is affected by a CRLF injection vulnerability when using SMTPS communication.
Severity
5.5 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-05-12 21:01 UTC
CWE
- CWE-93 - Improper neutralization of CRLF sequences ('CRLF injection')
Assigner
References
Impacted products
3 products
| Vendor | Product | Version | |
|---|---|---|---|
| Subnet Solutions | PowerSYSTEM Center 2020 |
Affected:
0 , ≤ 5.28.x
(custom)
|
|
| Subnet Solutions | PowerSYSTEM Center 2024 |
Affected:
6.0.x , ≤ 6.1.x
(custom)
|
|
| Subnet Solutions | PowerSYSTEM Center 2026 |
Affected:
7.0.x
|
Date Public
2026-05-13 05:00
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-35504",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-05-12T21:01:40.300358Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-05-12T21:12:55.834Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerSYSTEM Center 2020",
"vendor": "Subnet Solutions",
"versions": [
{
"lessThanOrEqual": "5.28.x",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "PowerSYSTEM Center 2024",
"vendor": "Subnet Solutions",
"versions": [
{
"lessThanOrEqual": "6.1.x",
"status": "affected",
"version": "6.0.x",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "PowerSYSTEM Center 2026",
"vendor": "Subnet Solutions",
"versions": [
{
"status": "affected",
"version": "7.0.x"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Kelly Stich of Subnet Solutions Inc. reported these vulnerabilities to CISA."
}
],
"datePublic": "2026-05-13T05:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "PowerSYSTEM Center email notification service is affected by a CRLF injection vulnerability when using SMTPS communication."
}
],
"value": "PowerSYSTEM Center email notification service is affected by a CRLF injection vulnerability when using SMTPS communication."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "ADJACENT",
"baseScore": 5.1,
"baseSeverity": "MEDIUM",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "LOW",
"vulnConfidentialityImpact": "LOW",
"vulnIntegrityImpact": "LOW",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "LOW",
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-93",
"description": "CWE-93 Improper neutralization of CRLF sequences (\u0027CRLF injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-05-12T20:45:23.739Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-132-02"
},
{
"url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-132-02.json"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Subnet Solutions recommends users update to the latest version of PowerSYSTEM Center PSC 2020 Update 29, PSC 2024 Update 2, and PSC 2026 GA Hotfix.\n\u003cbr\u003e\n\u003cbr\u003eFor assistance in upgrading, users should contact a Subnet Solutions System Integration team member or customer support team at (403) 270-8885 or by email at [support@subnet.com](mailto:support@subnet.com).\n\u003cbr\u003e\n\u003cbr\u003eSubnet Solutions recommends users do the following in order to reduce risk:\n\u003cbr\u003e* Monitor user activity records to ensure users are following acceptable usage policies of the application.\n\u003cbr\u003e* Restrict access to Notification Settings to trusted Administrators Monitor \"Send from Address\" in settings and Activity Records.\n\u003cbr\u003e* Configure a notification rule that triggers in any bulk account export activity."
}
],
"value": "Subnet Solutions recommends users update to the latest version of PowerSYSTEM Center PSC 2020 Update 29, PSC 2024 Update 2, and PSC 2026 GA Hotfix.\n\n\n\nFor assistance in upgrading, users should contact a Subnet Solutions System Integration team member or customer support team at (403) 270-8885 or by email at [support@subnet.com](mailto:support@subnet.com).\n\n\n\nSubnet Solutions recommends users do the following in order to reduce risk:\n\n* Monitor user activity records to ensure users are following acceptable usage policies of the application.\n\n* Restrict access to Notification Settings to trusted Administrators Monitor \"Send from Address\" in settings and Activity Records.\n\n* Configure a notification rule that triggers in any bulk account export activity."
}
],
"source": {
"advisory": "ICSA-26-132-02",
"discovery": "INTERNAL"
},
"title": "Subnet Solutions PowerSYSTEM Center CRLF injection",
"x_generator": {
"engine": "Vulnogram 1.0.2"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2026-35504",
"datePublished": "2026-05-12T20:19:38.126Z",
"dateReserved": "2026-04-16T14:05:42.158Z",
"dateUpdated": "2026-05-12T21:12:55.834Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}