Search

Find a vulnerability

Search criteria

    2 vulnerabilities found for PowerLogic PM5320 by Schneider Electric

    CVE-2024-9409 (GCVE-0-2024-9409)

    Vulnerability from nvd – Published: 2024-11-13 04:29 – Updated: 2024-11-13 14:43
    VLAI
    Summary
    CWE-400: An Uncontrolled Resource Consumption vulnerability exists that could cause the device to become unresponsive resulting in communication loss when a large amount of IGMP packets is present in the network.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-400 - Uncontrolled Resource Consumption
    Assigner
    Impacted products
    Vendor Product Version
    Schneider Electric PowerLogic PM5320 Affected: Version 2.3.8 and prior
    Create a notification for this product.
    Schneider Electric PowerLogic PM5340 Affected: Version 2.3.8 and prior
    Create a notification for this product.
    Schneider Electric PowerLogic PM5341 Affected: Version 2.6.6 and prior
    Create a notification for this product.
    schneider-electric powerlogic_pm5320 Affected: 0 , ≤ 2.3.8 (custom)
        cpe:2.3:h:schneider-electric:powerlogic_pm5320:*:*:*:*:*:*:*:*
    Create a notification for this product.
    schneider-electric powerlogic_pm5340 Affected: 0 , ≤ 2.3.8 (custom)
        cpe:2.3:h:schneider-electric:powerlogic_pm5340:*:*:*:*:*:*:*:*
    Create a notification for this product.
    schneider-electric powerlogic_pm5341 Affected: 0 , ≤ 2.6.6 (custom)
        cpe:2.3:h:schneider-electric:powerlogic_pm5341:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:h:schneider-electric:powerlogic_pm5320:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "powerlogic_pm5320",
                "vendor": "schneider-electric",
                "versions": [
                  {
                    "lessThanOrEqual": "2.3.8",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:h:schneider-electric:powerlogic_pm5340:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "powerlogic_pm5340",
                "vendor": "schneider-electric",
                "versions": [
                  {
                    "lessThanOrEqual": "2.3.8",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:h:schneider-electric:powerlogic_pm5341:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "powerlogic_pm5341",
                "vendor": "schneider-electric",
                "versions": [
                  {
                    "lessThanOrEqual": "2.6.6",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-9409",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-11-13T14:40:24.630364Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-11-13T14:43:17.912Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "PowerLogic PM5320",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "Version 2.3.8 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "PowerLogic PM5340",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "Version 2.3.8 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "PowerLogic PM5341",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "Version 2.6.6 and prior"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "CWE-400: An Uncontrolled Resource Consumption vulnerability exists that could cause the device to become\nunresponsive resulting in communication loss when a large amount of IGMP packets is present in the network.\n\n\u003cbr\u003e"
                }
              ],
              "value": "CWE-400: An Uncontrolled Resource Consumption vulnerability exists that could cause the device to become\nunresponsive resulting in communication loss when a large amount of IGMP packets is present in the network."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "NONE",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-400",
                  "description": "CWE-400 Uncontrolled Resource Consumption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-11-13T04:29:01.040Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "url": "https://download.schneider-electric.com/doc/SEVD-2024-317-01/SEVD-2024-317-01.pdf"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2024-9409",
        "datePublished": "2024-11-13T04:29:01.040Z",
        "dateReserved": "2024-10-01T12:08:25.066Z",
        "dateUpdated": "2024-11-13T14:43:17.912Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-9409 (GCVE-0-2024-9409)

    Vulnerability from cvelistv5 – Published: 2024-11-13 04:29 – Updated: 2024-11-13 14:43
    VLAI
    Summary
    CWE-400: An Uncontrolled Resource Consumption vulnerability exists that could cause the device to become unresponsive resulting in communication loss when a large amount of IGMP packets is present in the network.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-400 - Uncontrolled Resource Consumption
    Assigner
    Impacted products
    Vendor Product Version
    Schneider Electric PowerLogic PM5320 Affected: Version 2.3.8 and prior
    Create a notification for this product.
    Schneider Electric PowerLogic PM5340 Affected: Version 2.3.8 and prior
    Create a notification for this product.
    Schneider Electric PowerLogic PM5341 Affected: Version 2.6.6 and prior
    Create a notification for this product.
    schneider-electric powerlogic_pm5320 Affected: 0 , ≤ 2.3.8 (custom)
        cpe:2.3:h:schneider-electric:powerlogic_pm5320:*:*:*:*:*:*:*:*
    Create a notification for this product.
    schneider-electric powerlogic_pm5340 Affected: 0 , ≤ 2.3.8 (custom)
        cpe:2.3:h:schneider-electric:powerlogic_pm5340:*:*:*:*:*:*:*:*
    Create a notification for this product.
    schneider-electric powerlogic_pm5341 Affected: 0 , ≤ 2.6.6 (custom)
        cpe:2.3:h:schneider-electric:powerlogic_pm5341:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:h:schneider-electric:powerlogic_pm5320:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "powerlogic_pm5320",
                "vendor": "schneider-electric",
                "versions": [
                  {
                    "lessThanOrEqual": "2.3.8",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:h:schneider-electric:powerlogic_pm5340:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "powerlogic_pm5340",
                "vendor": "schneider-electric",
                "versions": [
                  {
                    "lessThanOrEqual": "2.3.8",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:h:schneider-electric:powerlogic_pm5341:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "powerlogic_pm5341",
                "vendor": "schneider-electric",
                "versions": [
                  {
                    "lessThanOrEqual": "2.6.6",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-9409",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-11-13T14:40:24.630364Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-11-13T14:43:17.912Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "PowerLogic PM5320",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "Version 2.3.8 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "PowerLogic PM5340",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "Version 2.3.8 and prior"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "PowerLogic PM5341",
              "vendor": "Schneider Electric",
              "versions": [
                {
                  "status": "affected",
                  "version": "Version 2.6.6 and prior"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "CWE-400: An Uncontrolled Resource Consumption vulnerability exists that could cause the device to become\nunresponsive resulting in communication loss when a large amount of IGMP packets is present in the network.\n\n\u003cbr\u003e"
                }
              ],
              "value": "CWE-400: An Uncontrolled Resource Consumption vulnerability exists that could cause the device to become\nunresponsive resulting in communication loss when a large amount of IGMP packets is present in the network."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "NONE",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-400",
                  "description": "CWE-400 Uncontrolled Resource Consumption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-11-13T04:29:01.040Z",
            "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
            "shortName": "schneider"
          },
          "references": [
            {
              "url": "https://download.schneider-electric.com/doc/SEVD-2024-317-01/SEVD-2024-317-01.pdf"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "assignerShortName": "schneider",
        "cveId": "CVE-2024-9409",
        "datePublished": "2024-11-13T04:29:01.040Z",
        "dateReserved": "2024-10-01T12:08:25.066Z",
        "dateUpdated": "2024-11-13T14:43:17.912Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }