Search criteria
2 vulnerabilities found for IoT Edge Linux docker by Advantech
CVE-2026-6888 (GCVE-0-2026-6888)
Vulnerability from nvd – Published: 2026-05-13 03:16 – Updated: 2026-05-13 14:35
VLAI?
Title
SQL Injection Vulnerability
Summary
Successful exploitation of the SQL injection vulnerability could allow a remote authenticated attacker to
execute arbitrary commands via a specific interface,
potentially enabling the attacker to access, modify, or delete sensitive
information within the database.
Severity ?
7.2 (High)
CWE
- CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Assigner
References
1 reference
Impacted products
8 products
| Vendor | Product | Version | |
|---|---|---|---|
| Advantech | SaaS Composer |
Affected:
prior to version 3.4.17
|
|
| Advantech | IoTSuite Growth Linux docker |
Affected:
prior to version 2.2.0
|
|
| Advantech | IoTSuite Starter Linux docker |
Affected:
prior to version 2.2.0
|
|
| Advantech | IoT Edge Linux docker |
Affected:
prior to version 2.2.0
|
|
| Advantech | IoT Edge Windows |
Affected:
prior to version 2.2.0
|
|
| Advantech | WebAccess/SCADA |
Affected:
prior to version 9.2.3
|
|
| Advantech | WebAccess SaaS-Composer |
Affected:
prior to version 3.4.17.1
|
|
| Advantech | ECOWatch SaaS-Composer |
Affected:
prior to version 3.4.17
|
Date Public ?
2026-05-13 02:54
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-6888",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-05-13T14:35:40.247452Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-89",
"description": "CWE-89 Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-05-13T14:35:53.880Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SaaS Composer",
"vendor": "Advantech",
"versions": [
{
"status": "affected",
"version": "prior to version 3.4.17"
}
]
},
{
"defaultStatus": "unknown",
"product": "IoTSuite Growth Linux docker",
"vendor": "Advantech",
"versions": [
{
"status": "affected",
"version": "prior to version 2.2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "IoTSuite Starter Linux docker",
"vendor": "Advantech",
"versions": [
{
"status": "affected",
"version": "prior to version 2.2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "IoT Edge Linux docker",
"vendor": "Advantech",
"versions": [
{
"status": "affected",
"version": "prior to version 2.2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "IoT Edge Windows",
"vendor": "Advantech",
"versions": [
{
"status": "affected",
"version": "prior to version 2.2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "WebAccess/SCADA",
"vendor": "Advantech",
"versions": [
{
"status": "affected",
"version": "prior to version 9.2.3"
}
]
},
{
"defaultStatus": "unknown",
"product": "WebAccess SaaS-Composer",
"vendor": "Advantech",
"versions": [
{
"status": "affected",
"version": "prior to version 3.4.17.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "ECOWatch SaaS-Composer",
"vendor": "Advantech",
"versions": [
{
"status": "affected",
"version": "prior to version 3.4.17"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Hoa Ly Van Huu"
}
],
"datePublic": "2026-05-13T02:54:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eSuccessful exploitation of the SQL injection vulnerability could allow a remote authenticated attacker to\nexecute arbitrary commands via a specific interface,\npotentially enabling the attacker to access, modify, or delete sensitive\ninformation within the database.\u003c/p\u003e"
}
],
"value": "Successful exploitation of the SQL injection vulnerability could allow a remote authenticated attacker to\nexecute arbitrary commands via a specific interface,\npotentially enabling the attacker to access, modify, or delete sensitive\ninformation within the database."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-05-13T03:16:24.701Z",
"orgId": "5f57b9bf-260d-4433-bf07-b6a79e9bb7d4",
"shortName": "CSA"
},
"references": [
{
"url": "https://www.csa.gov.sg/alerts-and-advisories/alerts/al-2026-050/"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eUsers and administrators of\naffected product versions are advised to update to the latest versions\nimmediately.\u003c/p\u003e\n\n\u003cp\u003eFor SaaS Composer, IoTSuite Growth\nLinux docker, IoT Edge Windows, and ECOWatch please contact Advantech\u0026nbsp;\u003ca href=\"https://wise-iot.advantech.com/en-tw/marketplace/help/technical-support\"\u003ehere\u0026nbsp;\u003c/a\u003efor\nthe official release of the fixed version.\u003c/p\u003e\n\n\u003cp\u003eFor IoTSuite Starter Linux docker,\nplease refer to the update guide\u0026nbsp;\u003ca href=\"https://portal-kbinsight-wiseiot-ensaas.practice.cloud.advantech.com/kb/library/detail/oPN5exOVNQq?tenantId=VGVuYW50.aSUET6-KO-0qXOBh\"\u003ehere\u003c/a\u003e.\nAs the update involves a reinstallation process, please refer to the\nreinstallation guide \u003ca href=\"https://portal-kbinsight-wiseiot-ensaas.practice.cloud.advantech.com/kb/library/detail/JqNWAMGz1JQ?tenantId=VGVuYW50.aSUET6-KO-0qXOBh\"\u003ehere\u003c/a\u003e.\u003c/p\u003e\n\n\u003cp\u003eFor IoT Edge Linux docker, please\nrefer to the update guide\u0026nbsp;\u003ca href=\"https://portal-kbinsight-wiseiot-ensaas.practice.cloud.advantech.com/kb/library/detail/oPN5exOVNQq?tenantId=VGVuYW50.aSUET6-KO-0qXOBh\"\u003ehere\u003c/a\u003e.\nAs the update involves a reinstallation process, please refer to the\nreinstallation guide \u003ca href=\"https://portal-kbinsight-wiseiot-ensaas.practice.cloud.advantech.com/kb/library/detail/G0yWBn2mp2q?tenantId=VGVuYW50.aSUET6-KO-0qXOBh\"\u003ehere\u003c/a\u003e.\u003c/p\u003e\n\n\u003cp\u003eFor WebAccess/SCADA and WebAccess\nSaaS-Composer, please refer to the update guide \u003ca href=\"https://www.advantech.com/en/support/details/installation?id=1-MS9MJV\"\u003ehere\u003c/a\u003e.\u003c/p\u003e"
}
],
"value": "Users and administrators of\naffected product versions are advised to update to the latest versions\nimmediately.\n\n\n\n\n\nFor SaaS Composer, IoTSuite Growth\nLinux docker, IoT Edge Windows, and ECOWatch please contact Advantech\u00a0 here\u00a0 https://wise-iot.advantech.com/en-tw/marketplace/help/technical-support for\nthe official release of the fixed version.\n\n\n\n\n\nFor IoTSuite Starter Linux docker,\nplease refer to the update guide\u00a0 here https://portal-kbinsight-wiseiot-ensaas.practice.cloud.advantech.com/kb/library/detail/oPN5exOVNQq .\nAs the update involves a reinstallation process, please refer to the\nreinstallation guide here https://portal-kbinsight-wiseiot-ensaas.practice.cloud.advantech.com/kb/library/detail/JqNWAMGz1JQ .\n\n\n\n\n\nFor IoT Edge Linux docker, please\nrefer to the update guide\u00a0 here https://portal-kbinsight-wiseiot-ensaas.practice.cloud.advantech.com/kb/library/detail/oPN5exOVNQq .\nAs the update involves a reinstallation process, please refer to the\nreinstallation guide here https://portal-kbinsight-wiseiot-ensaas.practice.cloud.advantech.com/kb/library/detail/G0yWBn2mp2q .\n\n\n\n\n\nFor WebAccess/SCADA and WebAccess\nSaaS-Composer, please refer to the update guide here https://www.advantech.com/en/support/details/installation ."
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "SQL Injection Vulnerability",
"x_generator": {
"engine": "Vulnogram 1.0.2"
}
}
},
"cveMetadata": {
"assignerOrgId": "5f57b9bf-260d-4433-bf07-b6a79e9bb7d4",
"assignerShortName": "CSA",
"cveId": "CVE-2026-6888",
"datePublished": "2026-05-13T03:16:24.701Z",
"dateReserved": "2026-04-23T02:58:12.750Z",
"dateUpdated": "2026-05-13T14:35:53.880Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-6888 (GCVE-0-2026-6888)
Vulnerability from cvelistv5 – Published: 2026-05-13 03:16 – Updated: 2026-05-13 14:35
VLAI?
Title
SQL Injection Vulnerability
Summary
Successful exploitation of the SQL injection vulnerability could allow a remote authenticated attacker to
execute arbitrary commands via a specific interface,
potentially enabling the attacker to access, modify, or delete sensitive
information within the database.
Severity ?
7.2 (High)
CWE
- CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Assigner
References
1 reference
Impacted products
8 products
| Vendor | Product | Version | |
|---|---|---|---|
| Advantech | SaaS Composer |
Affected:
prior to version 3.4.17
|
|
| Advantech | IoTSuite Growth Linux docker |
Affected:
prior to version 2.2.0
|
|
| Advantech | IoTSuite Starter Linux docker |
Affected:
prior to version 2.2.0
|
|
| Advantech | IoT Edge Linux docker |
Affected:
prior to version 2.2.0
|
|
| Advantech | IoT Edge Windows |
Affected:
prior to version 2.2.0
|
|
| Advantech | WebAccess/SCADA |
Affected:
prior to version 9.2.3
|
|
| Advantech | WebAccess SaaS-Composer |
Affected:
prior to version 3.4.17.1
|
|
| Advantech | ECOWatch SaaS-Composer |
Affected:
prior to version 3.4.17
|
Date Public ?
2026-05-13 02:54
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-6888",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-05-13T14:35:40.247452Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-89",
"description": "CWE-89 Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-05-13T14:35:53.880Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SaaS Composer",
"vendor": "Advantech",
"versions": [
{
"status": "affected",
"version": "prior to version 3.4.17"
}
]
},
{
"defaultStatus": "unknown",
"product": "IoTSuite Growth Linux docker",
"vendor": "Advantech",
"versions": [
{
"status": "affected",
"version": "prior to version 2.2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "IoTSuite Starter Linux docker",
"vendor": "Advantech",
"versions": [
{
"status": "affected",
"version": "prior to version 2.2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "IoT Edge Linux docker",
"vendor": "Advantech",
"versions": [
{
"status": "affected",
"version": "prior to version 2.2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "IoT Edge Windows",
"vendor": "Advantech",
"versions": [
{
"status": "affected",
"version": "prior to version 2.2.0"
}
]
},
{
"defaultStatus": "unknown",
"product": "WebAccess/SCADA",
"vendor": "Advantech",
"versions": [
{
"status": "affected",
"version": "prior to version 9.2.3"
}
]
},
{
"defaultStatus": "unknown",
"product": "WebAccess SaaS-Composer",
"vendor": "Advantech",
"versions": [
{
"status": "affected",
"version": "prior to version 3.4.17.1"
}
]
},
{
"defaultStatus": "unknown",
"product": "ECOWatch SaaS-Composer",
"vendor": "Advantech",
"versions": [
{
"status": "affected",
"version": "prior to version 3.4.17"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Hoa Ly Van Huu"
}
],
"datePublic": "2026-05-13T02:54:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eSuccessful exploitation of the SQL injection vulnerability could allow a remote authenticated attacker to\nexecute arbitrary commands via a specific interface,\npotentially enabling the attacker to access, modify, or delete sensitive\ninformation within the database.\u003c/p\u003e"
}
],
"value": "Successful exploitation of the SQL injection vulnerability could allow a remote authenticated attacker to\nexecute arbitrary commands via a specific interface,\npotentially enabling the attacker to access, modify, or delete sensitive\ninformation within the database."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-05-13T03:16:24.701Z",
"orgId": "5f57b9bf-260d-4433-bf07-b6a79e9bb7d4",
"shortName": "CSA"
},
"references": [
{
"url": "https://www.csa.gov.sg/alerts-and-advisories/alerts/al-2026-050/"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eUsers and administrators of\naffected product versions are advised to update to the latest versions\nimmediately.\u003c/p\u003e\n\n\u003cp\u003eFor SaaS Composer, IoTSuite Growth\nLinux docker, IoT Edge Windows, and ECOWatch please contact Advantech\u0026nbsp;\u003ca href=\"https://wise-iot.advantech.com/en-tw/marketplace/help/technical-support\"\u003ehere\u0026nbsp;\u003c/a\u003efor\nthe official release of the fixed version.\u003c/p\u003e\n\n\u003cp\u003eFor IoTSuite Starter Linux docker,\nplease refer to the update guide\u0026nbsp;\u003ca href=\"https://portal-kbinsight-wiseiot-ensaas.practice.cloud.advantech.com/kb/library/detail/oPN5exOVNQq?tenantId=VGVuYW50.aSUET6-KO-0qXOBh\"\u003ehere\u003c/a\u003e.\nAs the update involves a reinstallation process, please refer to the\nreinstallation guide \u003ca href=\"https://portal-kbinsight-wiseiot-ensaas.practice.cloud.advantech.com/kb/library/detail/JqNWAMGz1JQ?tenantId=VGVuYW50.aSUET6-KO-0qXOBh\"\u003ehere\u003c/a\u003e.\u003c/p\u003e\n\n\u003cp\u003eFor IoT Edge Linux docker, please\nrefer to the update guide\u0026nbsp;\u003ca href=\"https://portal-kbinsight-wiseiot-ensaas.practice.cloud.advantech.com/kb/library/detail/oPN5exOVNQq?tenantId=VGVuYW50.aSUET6-KO-0qXOBh\"\u003ehere\u003c/a\u003e.\nAs the update involves a reinstallation process, please refer to the\nreinstallation guide \u003ca href=\"https://portal-kbinsight-wiseiot-ensaas.practice.cloud.advantech.com/kb/library/detail/G0yWBn2mp2q?tenantId=VGVuYW50.aSUET6-KO-0qXOBh\"\u003ehere\u003c/a\u003e.\u003c/p\u003e\n\n\u003cp\u003eFor WebAccess/SCADA and WebAccess\nSaaS-Composer, please refer to the update guide \u003ca href=\"https://www.advantech.com/en/support/details/installation?id=1-MS9MJV\"\u003ehere\u003c/a\u003e.\u003c/p\u003e"
}
],
"value": "Users and administrators of\naffected product versions are advised to update to the latest versions\nimmediately.\n\n\n\n\n\nFor SaaS Composer, IoTSuite Growth\nLinux docker, IoT Edge Windows, and ECOWatch please contact Advantech\u00a0 here\u00a0 https://wise-iot.advantech.com/en-tw/marketplace/help/technical-support for\nthe official release of the fixed version.\n\n\n\n\n\nFor IoTSuite Starter Linux docker,\nplease refer to the update guide\u00a0 here https://portal-kbinsight-wiseiot-ensaas.practice.cloud.advantech.com/kb/library/detail/oPN5exOVNQq .\nAs the update involves a reinstallation process, please refer to the\nreinstallation guide here https://portal-kbinsight-wiseiot-ensaas.practice.cloud.advantech.com/kb/library/detail/JqNWAMGz1JQ .\n\n\n\n\n\nFor IoT Edge Linux docker, please\nrefer to the update guide\u00a0 here https://portal-kbinsight-wiseiot-ensaas.practice.cloud.advantech.com/kb/library/detail/oPN5exOVNQq .\nAs the update involves a reinstallation process, please refer to the\nreinstallation guide here https://portal-kbinsight-wiseiot-ensaas.practice.cloud.advantech.com/kb/library/detail/G0yWBn2mp2q .\n\n\n\n\n\nFor WebAccess/SCADA and WebAccess\nSaaS-Composer, please refer to the update guide here https://www.advantech.com/en/support/details/installation ."
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "SQL Injection Vulnerability",
"x_generator": {
"engine": "Vulnogram 1.0.2"
}
}
},
"cveMetadata": {
"assignerOrgId": "5f57b9bf-260d-4433-bf07-b6a79e9bb7d4",
"assignerShortName": "CSA",
"cveId": "CVE-2026-6888",
"datePublished": "2026-05-13T03:16:24.701Z",
"dateReserved": "2026-04-23T02:58:12.750Z",
"dateUpdated": "2026-05-13T14:35:53.880Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}