    CVE-2025-27769 (GCVE-0-2025-27769)

    Vulnerability from nvd – Published: 2026-03-10 16:07 – Updated: 2026-03-10 16:41
    VLAI
    Summary
    A vulnerability has been identified in Heliox Flex 180 kW EV Charging Station (All versions < F4.11.1), Heliox Mobile DC 40 kW EV Charging Station (All versions < L4.10.1). Affected devices contain improper access control that could allow an attacker to reach unauthorized services via the charging cable.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-923 - Improper Restriction of Communication Channel to Intended Endpoints
    Assigner
    Impacted products
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-27769",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-03-10T16:33:20.023387Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-03-10T16:41:10.032Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Heliox Flex 180 kW EV Charging Station",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "F4.11.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Heliox Mobile DC 40 kW EV Charging Station",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "L4.10.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in Heliox Flex 180 kW EV Charging Station (All versions \u003c F4.11.1), Heliox Mobile DC 40 kW EV Charging Station (All versions \u003c L4.10.1). Affected devices contain improper access control that could allow an attacker to reach unauthorized services via the charging cable."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 2.6,
                "baseSeverity": "LOW",
                "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:C/C:L/I:N/A:N",
                "version": "3.1"
              }
            },
            {
              "cvssV4_0": {
                "baseScore": 2.4,
                "baseSeverity": "LOW",
                "vectorString": "CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:L/SI:N/SA:N",
                "version": "4.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-923",
                  "description": "CWE-923: Improper Restriction of Communication Channel to Intended Endpoints",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-03-10T16:07:43.641Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-126399.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2025-27769",
        "datePublished": "2026-03-10T16:07:43.641Z",
        "dateReserved": "2025-03-06T16:53:49.577Z",
        "dateUpdated": "2026-03-10T16:41:10.032Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-27769 (GCVE-0-2025-27769)

    Vulnerability from cvelistv5 – Published: 2026-03-10 16:07 – Updated: 2026-03-10 16:41
    VLAI
    Summary
    A vulnerability has been identified in Heliox Flex 180 kW EV Charging Station (All versions < F4.11.1), Heliox Mobile DC 40 kW EV Charging Station (All versions < L4.10.1). Affected devices contain improper access control that could allow an attacker to reach unauthorized services via the charging cable.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-923 - Improper Restriction of Communication Channel to Intended Endpoints
    Assigner
    Impacted products
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-27769",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-03-10T16:33:20.023387Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-03-10T16:41:10.032Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unknown",
              "product": "Heliox Flex 180 kW EV Charging Station",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "F4.11.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unknown",
              "product": "Heliox Mobile DC 40 kW EV Charging Station",
              "vendor": "Siemens",
              "versions": [
                {
                  "lessThan": "L4.10.1",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability has been identified in Heliox Flex 180 kW EV Charging Station (All versions \u003c F4.11.1), Heliox Mobile DC 40 kW EV Charging Station (All versions \u003c L4.10.1). Affected devices contain improper access control that could allow an attacker to reach unauthorized services via the charging cable."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 2.6,
                "baseSeverity": "LOW",
                "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:C/C:L/I:N/A:N",
                "version": "3.1"
              }
            },
            {
              "cvssV4_0": {
                "baseScore": 2.4,
                "baseSeverity": "LOW",
                "vectorString": "CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:L/SI:N/SA:N",
                "version": "4.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-923",
                  "description": "CWE-923: Improper Restriction of Communication Channel to Intended Endpoints",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-03-10T16:07:43.641Z",
            "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
            "shortName": "siemens"
          },
          "references": [
            {
              "url": "https://cert-portal.siemens.com/productcert/html/ssa-126399.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "assignerShortName": "siemens",
        "cveId": "CVE-2025-27769",
        "datePublished": "2026-03-10T16:07:43.641Z",
        "dateReserved": "2025-03-06T16:53:49.577Z",
        "dateUpdated": "2026-03-10T16:41:10.032Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }