Search

Find a vulnerability

Search criteria

    7 vulnerabilities found for GT23 Model by Mitsubishi Electric

    VAR-202007-1224

    Vulnerability from variot - Updated: 2024-11-23 22:05

    TCP/IP function included in the firmware of Mitsubishi Electric GOT2000 series (CoreOS with version -Y and earlier installed in GT27 Model, GT25 Model, and GT23 Model) does not properly manage sessions, which may allow a remote attacker to stop the network functions of the products or execute a malicious program via a specially crafted packet. Mitsubishi Electric GT27, etc. are all a GOT2000 series of graphic operation terminals from Mitsubishi Electric of Japan.

    CoreOS Y and previous versions in Mitsubishi Electric GT27, GT25, and GT23 (GOT2000 series) have authorization issue vulnerabilities. Attackers can use this vulnerability to cause TCP connection failure

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202007-1224",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "coreos",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "mitsubishielectric",
            "version": "y"
          },
          {
            "model": "gt23 model",
            "scope": null,
            "trust": 0.8,
            "vendor": "mitsubishi electric",
            "version": null
          },
          {
            "model": "gt25 model",
            "scope": null,
            "trust": 0.8,
            "vendor": "mitsubishi electric",
            "version": null
          },
          {
            "model": "gt27 model",
            "scope": null,
            "trust": 0.8,
            "vendor": "mitsubishi electric",
            "version": null
          },
          {
            "model": "electric gt23 model",
            "scope": null,
            "trust": 0.6,
            "vendor": "mitsubishi",
            "version": null
          },
          {
            "model": "electric gt25 model",
            "scope": null,
            "trust": 0.6,
            "vendor": "mitsubishi",
            "version": null
          },
          {
            "model": "electric gt27 model",
            "scope": null,
            "trust": 0.6,
            "vendor": "mitsubishi",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2020-38410"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-006469"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-5596"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "cpe_match": [
                  {
                    "cpe22Uri": "cpe:/o:mitsubishielectric:gt23_model",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:mitsubishielectric:gt25_model",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:mitsubishielectric:gt27_model",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-006469"
          }
        ]
      },
      "cve": "CVE-2020-5596",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "NONE",
                "baseScore": 5.0,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 10.0,
                "id": "CVE-2020-5596",
                "impactScore": 2.9,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 1.0,
                "vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:N",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 7.8,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2020-38410",
                "impactScore": 6.9,
                "integrityImpact": "NONE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "NONE",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 3.9,
                "id": "CVE-2020-5596",
                "impactScore": 3.6,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "IPA score",
                "availabilityImpact": "High",
                "baseScore": 9.8,
                "baseSeverity": "Critical",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "JVNDB-2020-006469",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2020-5596",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "IPA",
                "id": "JVNDB-2020-006469",
                "trust": 0.8,
                "value": "Critical"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2020-38410",
                "trust": 0.6,
                "value": "HIGH"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202007-305",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2020-38410"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-006469"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202007-305"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-5596"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "TCP/IP function included in the firmware of Mitsubishi Electric GOT2000 series (CoreOS with version -Y and earlier installed in GT27 Model, GT25 Model, and GT23 Model) does not properly manage sessions, which may allow a remote attacker to stop the network functions of the products or execute a malicious program via a specially crafted packet. Mitsubishi Electric GT27, etc. are all a GOT2000 series of graphic operation terminals from Mitsubishi Electric of Japan. \n\r\n\r\nCoreOS Y and previous versions in Mitsubishi Electric GT27, GT25, and GT23 (GOT2000 series) have authorization issue vulnerabilities. Attackers can use this vulnerability to cause TCP connection failure",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2020-5596"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-006469"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2020-38410"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2020-5596",
            "trust": 3.0
          },
          {
            "db": "JVN",
            "id": "JVNVU95413676",
            "trust": 2.4
          },
          {
            "db": "ICS CERT",
            "id": "ICSA-20-189-02",
            "trust": 2.0
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-006469",
            "trust": 1.4
          },
          {
            "db": "CNVD",
            "id": "CNVD-2020-38410",
            "trust": 0.6
          },
          {
            "db": "AUSCERT",
            "id": "ESB-2020.2312",
            "trust": 0.6
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202007-305",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2020-38410"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-006469"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202007-305"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-5596"
          }
        ]
      },
      "id": "VAR-202007-1224",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2020-38410"
          }
        ],
        "trust": 1.54642855
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "ICS",
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2020-38410"
          }
        ]
      },
      "last_update_date": "2024-11-23T22:05:45.706000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "GOT2000\u30b7\u30ea\u30fc\u30ba\u306b\u304a\u3051\u308bTCP/IP\u30b9\u30bf\u30c3\u30af\u306e\u8907\u6570\u306e\u8106\u5f31\u6027",
            "trust": 0.8,
            "url": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-005.pdf"
          },
          {
            "title": "Patch for Multiple Mitsubishi Electric product authorization issues and vulnerabilities",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/248851"
          },
          {
            "title": "Multiple Mitsubishi Electric Product Authorization Issue Vulnerability Fixing Measures",
            "trust": 0.6,
            "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=123230"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2020-38410"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-006469"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202007-305"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-384",
            "trust": 1.8
          },
          {
            "problemtype": "CWE-476",
            "trust": 0.8
          },
          {
            "problemtype": "CWE-119",
            "trust": 0.8
          },
          {
            "problemtype": "CWE-399",
            "trust": 0.8
          },
          {
            "problemtype": "CWE-88",
            "trust": 0.8
          },
          {
            "problemtype": "CWE-284",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-006469"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-5596"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.0,
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-189-02"
          },
          {
            "trust": 1.6,
            "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-005_en.pdf"
          },
          {
            "trust": 1.6,
            "url": "https://jvn.jp/en/vu/jvnvu95413676/index.html"
          },
          {
            "trust": 0.8,
            "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-5598"
          },
          {
            "trust": 0.8,
            "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-5599"
          },
          {
            "trust": 0.8,
            "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-5600"
          },
          {
            "trust": 0.8,
            "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-5595"
          },
          {
            "trust": 0.8,
            "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-5596"
          },
          {
            "trust": 0.8,
            "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-5597"
          },
          {
            "trust": 0.8,
            "url": "https://jvn.jp/vu/jvnvu95413676/index.html"
          },
          {
            "trust": 0.6,
            "url": "https://jvndb.jvn.jp/en/contents/2020/jvndb-2020-006469.html"
          },
          {
            "trust": 0.6,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2020-5596"
          },
          {
            "trust": 0.6,
            "url": "https://www.auscert.org.au/bulletins/esb-2020.2312/"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2020-38410"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-006469"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202007-305"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-5596"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2020-38410"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-006469"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202007-305"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-5596"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2020-07-13T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2020-38410"
          },
          {
            "date": "2020-07-09T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2020-006469"
          },
          {
            "date": "2020-07-07T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202007-305"
          },
          {
            "date": "2020-07-07T09:15:10.153000",
            "db": "NVD",
            "id": "CVE-2020-5596"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2021-02-23T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2020-38410"
          },
          {
            "date": "2020-07-09T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2020-006469"
          },
          {
            "date": "2020-07-15T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202007-305"
          },
          {
            "date": "2024-11-21T05:34:20.100000",
            "db": "NVD",
            "id": "CVE-2020-5596"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202007-305"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Made by Mitsubishi Electric  GOT2000 Of the series  TCP/IP Multiple vulnerabilities in functionality",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-006469"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "authorization issue",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202007-305"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202007-1223

    Vulnerability from variot - Updated: 2024-11-23 22:05

    TCP/IP function included in the firmware of Mitsubishi Electric GOT2000 series (CoreOS with version -Y and earlier installed in GT27 Model, GT25 Model, and GT23 Model) contains a buffer overflow vulnerability, which may allow a remote attacker to stop the network functions of the products or execute a malicious program via a specially crafted packet. Mitsubishi Electric GT27, etc. are all a GOT2000 series of graphic operation terminals from Mitsubishi Electric of Japan.

    CoreOS Y and earlier versions in Mitsubishi Electric GT27, GT25, and GT23 (GOT2000 series) have a buffer overflow vulnerability. Attackers can use this vulnerability to cause the device to crash and execute code

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202007-1223",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "coreos",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "mitsubishielectric",
            "version": "y"
          },
          {
            "model": "gt23 model",
            "scope": null,
            "trust": 0.8,
            "vendor": "mitsubishi electric",
            "version": null
          },
          {
            "model": "gt25 model",
            "scope": null,
            "trust": 0.8,
            "vendor": "mitsubishi electric",
            "version": null
          },
          {
            "model": "gt27 model",
            "scope": null,
            "trust": 0.8,
            "vendor": "mitsubishi electric",
            "version": null
          },
          {
            "model": "electric gt23 model",
            "scope": null,
            "trust": 0.6,
            "vendor": "mitsubishi",
            "version": null
          },
          {
            "model": "electric gt25 model",
            "scope": null,
            "trust": 0.6,
            "vendor": "mitsubishi",
            "version": null
          },
          {
            "model": "electric gt27 model",
            "scope": null,
            "trust": 0.6,
            "vendor": "mitsubishi",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2020-38411"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-006469"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-5595"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "cpe_match": [
                  {
                    "cpe22Uri": "cpe:/o:mitsubishielectric:gt23_model",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:mitsubishielectric:gt25_model",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:mitsubishielectric:gt27_model",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-006469"
          }
        ]
      },
      "cve": "CVE-2020-5595",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "PARTIAL",
                "baseScore": 7.5,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 10.0,
                "id": "CVE-2020-5595",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "HIGH",
                "trust": 1.0,
                "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 10.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2020-38411",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "id": "CVE-2020-5595",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "IPA score",
                "availabilityImpact": "High",
                "baseScore": 9.8,
                "baseSeverity": "Critical",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "JVNDB-2020-006469",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2020-5595",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "IPA",
                "id": "JVNDB-2020-006469",
                "trust": 0.8,
                "value": "Critical"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2020-38411",
                "trust": 0.6,
                "value": "HIGH"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202007-304",
                "trust": 0.6,
                "value": "CRITICAL"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2020-38411"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-006469"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202007-304"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-5595"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "TCP/IP function included in the firmware of Mitsubishi Electric GOT2000 series (CoreOS with version -Y and earlier installed in GT27 Model, GT25 Model, and GT23 Model) contains a buffer overflow vulnerability, which may allow a remote attacker to stop the network functions of the products or execute a malicious program via a specially crafted packet. Mitsubishi Electric GT27, etc. are all a GOT2000 series of graphic operation terminals from Mitsubishi Electric of Japan. \n\r\n\r\nCoreOS Y and earlier versions in Mitsubishi Electric GT27, GT25, and GT23 (GOT2000 series) have a buffer overflow vulnerability. Attackers can use this vulnerability to cause the device to crash and execute code",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2020-5595"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-006469"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2020-38411"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2020-5595",
            "trust": 3.0
          },
          {
            "db": "JVN",
            "id": "JVNVU95413676",
            "trust": 2.4
          },
          {
            "db": "ICS CERT",
            "id": "ICSA-20-189-02",
            "trust": 2.0
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-006469",
            "trust": 1.4
          },
          {
            "db": "CNVD",
            "id": "CNVD-2020-38411",
            "trust": 0.6
          },
          {
            "db": "AUSCERT",
            "id": "ESB-2020.2312",
            "trust": 0.6
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202007-304",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2020-38411"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-006469"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202007-304"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-5595"
          }
        ]
      },
      "id": "VAR-202007-1223",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2020-38411"
          }
        ],
        "trust": 1.54642855
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "ICS",
              "Network device"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2020-38411"
          }
        ]
      },
      "last_update_date": "2024-11-23T22:05:45.679000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "GOT2000\u30b7\u30ea\u30fc\u30ba\u306b\u304a\u3051\u308bTCP/IP\u30b9\u30bf\u30c3\u30af\u306e\u8907\u6570\u306e\u8106\u5f31\u6027",
            "trust": 0.8,
            "url": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-005.pdf"
          },
          {
            "title": "Patch for Buffer overflow vulnerabilities in multiple Mitsubishi Electric products",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/248901"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2020-38411"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-006469"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-120",
            "trust": 1.0
          },
          {
            "problemtype": "CWE-476",
            "trust": 0.8
          },
          {
            "problemtype": "CWE-384",
            "trust": 0.8
          },
          {
            "problemtype": "CWE-119",
            "trust": 0.8
          },
          {
            "problemtype": "CWE-399",
            "trust": 0.8
          },
          {
            "problemtype": "CWE-88",
            "trust": 0.8
          },
          {
            "problemtype": "CWE-284",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-006469"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-5595"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.0,
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-189-02"
          },
          {
            "trust": 1.6,
            "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-005_en.pdf"
          },
          {
            "trust": 1.6,
            "url": "https://jvn.jp/en/vu/jvnvu95413676/index.html"
          },
          {
            "trust": 0.8,
            "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-5598"
          },
          {
            "trust": 0.8,
            "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-5599"
          },
          {
            "trust": 0.8,
            "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-5600"
          },
          {
            "trust": 0.8,
            "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-5595"
          },
          {
            "trust": 0.8,
            "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-5596"
          },
          {
            "trust": 0.8,
            "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-5597"
          },
          {
            "trust": 0.8,
            "url": "https://jvn.jp/vu/jvnvu95413676/index.html"
          },
          {
            "trust": 0.6,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2020-5595"
          },
          {
            "trust": 0.6,
            "url": "https://jvndb.jvn.jp/en/contents/2020/jvndb-2020-006469.html"
          },
          {
            "trust": 0.6,
            "url": "https://www.auscert.org.au/bulletins/esb-2020.2312/"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2020-38411"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-006469"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202007-304"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-5595"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2020-38411"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-006469"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202007-304"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-5595"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2020-07-13T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2020-38411"
          },
          {
            "date": "2020-07-09T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2020-006469"
          },
          {
            "date": "2020-07-07T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202007-304"
          },
          {
            "date": "2020-07-07T09:15:10.057000",
            "db": "NVD",
            "id": "CVE-2020-5595"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2021-02-23T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2020-38411"
          },
          {
            "date": "2020-07-09T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2020-006469"
          },
          {
            "date": "2020-07-15T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202007-304"
          },
          {
            "date": "2024-11-21T05:34:20",
            "db": "NVD",
            "id": "CVE-2020-5595"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202007-304"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Made by Mitsubishi Electric  GOT2000 Of the series  TCP/IP Multiple vulnerabilities in functionality",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-006469"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "buffer error",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202007-304"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202007-1225

    Vulnerability from variot - Updated: 2024-11-23 22:05

    TCP/IP function included in the firmware of Mitsubishi Electric GOT2000 series (CoreOS with version -Y and earlier installed in GT27 Model, GT25 Model, and GT23 Model) contains a null pointer dereference vulnerability, which may allow a remote attacker to stop the network functions of the products or execute a malicious program via a specially crafted packet. Mitsubishi Electric GT27, etc. are all a GOT2000 series graphical operation terminal of Japan's Mitsubishi Electric.

    CoreOS Y and previous versions of Mitsubishi Electric GT27, GT25, and GT23 (GOT2000 series) have a null pointer reference vulnerability. Attackers can use this vulnerability to cause denial of service and device crash

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202007-1225",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "coreos",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "mitsubishielectric",
            "version": "y"
          },
          {
            "model": "gt23 model",
            "scope": null,
            "trust": 0.8,
            "vendor": "mitsubishi electric",
            "version": null
          },
          {
            "model": "gt25 model",
            "scope": null,
            "trust": 0.8,
            "vendor": "mitsubishi electric",
            "version": null
          },
          {
            "model": "gt27 model",
            "scope": null,
            "trust": 0.8,
            "vendor": "mitsubishi electric",
            "version": null
          },
          {
            "model": "electric gt27 model",
            "scope": null,
            "trust": 0.6,
            "vendor": "mitsubishi",
            "version": null
          },
          {
            "model": "electric gt25 model",
            "scope": null,
            "trust": 0.6,
            "vendor": "mitsubishi",
            "version": null
          },
          {
            "model": "electric gt23 model",
            "scope": null,
            "trust": 0.6,
            "vendor": "mitsubishi",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2020-46801"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-006469"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-5597"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "cpe_match": [
                  {
                    "cpe22Uri": "cpe:/o:mitsubishielectric:gt23_model",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:mitsubishielectric:gt25_model",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:mitsubishielectric:gt27_model",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-006469"
          }
        ]
      },
      "cve": "CVE-2020-5597",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "PARTIAL",
                "baseScore": 5.0,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 10.0,
                "id": "CVE-2020-5597",
                "impactScore": 2.9,
                "integrityImpact": "NONE",
                "severity": "MEDIUM",
                "trust": 1.0,
                "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "PARTIAL",
                "baseScore": 5.0,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2020-46801",
                "impactScore": 2.9,
                "integrityImpact": "NONE",
                "severity": "MEDIUM",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 3.9,
                "id": "CVE-2020-5597",
                "impactScore": 3.6,
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "IPA score",
                "availabilityImpact": "High",
                "baseScore": 9.8,
                "baseSeverity": "Critical",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "JVNDB-2020-006469",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2020-5597",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "IPA",
                "id": "JVNDB-2020-006469",
                "trust": 0.8,
                "value": "Critical"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2020-46801",
                "trust": 0.6,
                "value": "MEDIUM"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202007-306",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2020-46801"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-006469"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202007-306"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-5597"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "TCP/IP function included in the firmware of Mitsubishi Electric GOT2000 series (CoreOS with version -Y and earlier installed in GT27 Model, GT25 Model, and GT23 Model) contains a null pointer dereference vulnerability, which may allow a remote attacker to stop the network functions of the products or execute a malicious program via a specially crafted packet. Mitsubishi Electric GT27, etc. are all a GOT2000 series graphical operation terminal of Japan\u0027s Mitsubishi Electric. \n\r\n\r\nCoreOS Y and previous versions of Mitsubishi Electric GT27, GT25, and GT23 (GOT2000 series) have a null pointer reference vulnerability. Attackers can use this vulnerability to cause denial of service and device crash",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2020-5597"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-006469"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2020-46801"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2020-5597",
            "trust": 3.0
          },
          {
            "db": "JVN",
            "id": "JVNVU95413676",
            "trust": 2.4
          },
          {
            "db": "ICS CERT",
            "id": "ICSA-20-189-02",
            "trust": 2.0
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-006469",
            "trust": 1.4
          },
          {
            "db": "CNVD",
            "id": "CNVD-2020-46801",
            "trust": 0.6
          },
          {
            "db": "AUSCERT",
            "id": "ESB-2020.2312",
            "trust": 0.6
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202007-306",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2020-46801"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-006469"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202007-306"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-5597"
          }
        ]
      },
      "id": "VAR-202007-1225",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2020-46801"
          }
        ],
        "trust": 1.54642855
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "ICS"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2020-46801"
          }
        ]
      },
      "last_update_date": "2024-11-23T22:05:45.653000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "GOT2000\u30b7\u30ea\u30fc\u30ba\u306b\u304a\u3051\u308bTCP/IP\u30b9\u30bf\u30c3\u30af\u306e\u8907\u6570\u306e\u8106\u5f31\u6027",
            "trust": 0.8,
            "url": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-005.pdf"
          },
          {
            "title": "Patch for Null pointer reference vulnerabilities in multiple Mitsubishi Electric products",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/231106"
          },
          {
            "title": "Multiple Mitsubishi Electric Product code issue vulnerability fixes",
            "trust": 0.6,
            "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=123231"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2020-46801"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-006469"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202007-306"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-476",
            "trust": 1.8
          },
          {
            "problemtype": "CWE-384",
            "trust": 0.8
          },
          {
            "problemtype": "CWE-119",
            "trust": 0.8
          },
          {
            "problemtype": "CWE-399",
            "trust": 0.8
          },
          {
            "problemtype": "CWE-88",
            "trust": 0.8
          },
          {
            "problemtype": "CWE-284",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-006469"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-5597"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.0,
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-189-02"
          },
          {
            "trust": 1.6,
            "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-005_en.pdf"
          },
          {
            "trust": 1.6,
            "url": "https://jvn.jp/en/vu/jvnvu95413676/index.html"
          },
          {
            "trust": 0.8,
            "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-5598"
          },
          {
            "trust": 0.8,
            "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-5599"
          },
          {
            "trust": 0.8,
            "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-5600"
          },
          {
            "trust": 0.8,
            "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-5595"
          },
          {
            "trust": 0.8,
            "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-5596"
          },
          {
            "trust": 0.8,
            "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-5597"
          },
          {
            "trust": 0.8,
            "url": "https://jvn.jp/vu/jvnvu95413676/index.html"
          },
          {
            "trust": 0.6,
            "url": "https://jvndb.jvn.jp/en/contents/2020/jvndb-2020-006469.html"
          },
          {
            "trust": 0.6,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2020-5597"
          },
          {
            "trust": 0.6,
            "url": "https://www.auscert.org.au/bulletins/esb-2020.2312/"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2020-46801"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-006469"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202007-306"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-5597"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2020-46801"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-006469"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202007-306"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-5597"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2020-08-19T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2020-46801"
          },
          {
            "date": "2020-07-09T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2020-006469"
          },
          {
            "date": "2020-07-07T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202007-306"
          },
          {
            "date": "2020-07-07T09:15:10.230000",
            "db": "NVD",
            "id": "CVE-2020-5597"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2020-08-19T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2020-46801"
          },
          {
            "date": "2020-07-09T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2020-006469"
          },
          {
            "date": "2020-07-15T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202007-306"
          },
          {
            "date": "2024-11-21T05:34:20.197000",
            "db": "NVD",
            "id": "CVE-2020-5597"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202007-306"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Made by Mitsubishi Electric  GOT2000 Of the series  TCP/IP Multiple vulnerabilities in functionality",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-006469"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "code problem",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202007-306"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202007-1228

    Vulnerability from variot - Updated: 2024-11-23 22:05

    TCP/IP function included in the firmware of Mitsubishi Electric GOT2000 series (CoreOS with version -Y and earlier installed in GT27 Model, GT25 Model, and GT23 Model) contains a resource management error vulnerability, which may allow a remote attacker to stop the network functions of the products or execute a malicious program via a specially crafted packet. Mitsubishi Electric GT27, etc. are all a GOT2000 series graphical operation terminal of Japan's Mitsubishi Electric.

    CoreOS Y and previous versions of Mitsubishi Electric GT27, GT25, and GT23 (GOT2000 series) have a resource management error vulnerability. Attackers can use this vulnerability to obtain sensitive information

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202007-1228",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "coreos",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "mitsubishielectric",
            "version": "y"
          },
          {
            "model": "gt23 model",
            "scope": null,
            "trust": 0.8,
            "vendor": "mitsubishi electric",
            "version": null
          },
          {
            "model": "gt25 model",
            "scope": null,
            "trust": 0.8,
            "vendor": "mitsubishi electric",
            "version": null
          },
          {
            "model": "gt27 model",
            "scope": null,
            "trust": 0.8,
            "vendor": "mitsubishi electric",
            "version": null
          },
          {
            "model": "electric gt27 model",
            "scope": null,
            "trust": 0.6,
            "vendor": "mitsubishi",
            "version": null
          },
          {
            "model": "electric gt25 model",
            "scope": null,
            "trust": 0.6,
            "vendor": "mitsubishi",
            "version": null
          },
          {
            "model": "electric gt23 model",
            "scope": null,
            "trust": 0.6,
            "vendor": "mitsubishi",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2020-46798"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-006469"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-5600"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "cpe_match": [
                  {
                    "cpe22Uri": "cpe:/o:mitsubishielectric:gt23_model",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:mitsubishielectric:gt25_model",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:mitsubishielectric:gt27_model",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-006469"
          }
        ]
      },
      "cve": "CVE-2020-5600",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "PARTIAL",
                "baseScore": 5.0,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 10.0,
                "id": "CVE-2020-5600",
                "impactScore": 2.9,
                "integrityImpact": "NONE",
                "severity": "MEDIUM",
                "trust": 1.0,
                "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "NONE",
                "baseScore": 5.0,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2020-46798",
                "impactScore": 2.9,
                "integrityImpact": "NONE",
                "severity": "MEDIUM",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 3.9,
                "id": "CVE-2020-5600",
                "impactScore": 3.6,
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "IPA score",
                "availabilityImpact": "High",
                "baseScore": 9.8,
                "baseSeverity": "Critical",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "JVNDB-2020-006469",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2020-5600",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "IPA",
                "id": "JVNDB-2020-006469",
                "trust": 0.8,
                "value": "Critical"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2020-46798",
                "trust": 0.6,
                "value": "MEDIUM"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202007-308",
                "trust": 0.6,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2020-46798"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-006469"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202007-308"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-5600"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "TCP/IP function included in the firmware of Mitsubishi Electric GOT2000 series (CoreOS with version -Y and earlier installed in GT27 Model, GT25 Model, and GT23 Model) contains a resource management error vulnerability, which may allow a remote attacker to stop the network functions of the products or execute a malicious program via a specially crafted packet. Mitsubishi Electric GT27, etc. are all a GOT2000 series graphical operation terminal of Japan\u0027s Mitsubishi Electric. \n\r\n\r\nCoreOS Y and previous versions of Mitsubishi Electric GT27, GT25, and GT23 (GOT2000 series) have a resource management error vulnerability. Attackers can use this vulnerability to obtain sensitive information",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2020-5600"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-006469"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2020-46798"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2020-5600",
            "trust": 3.0
          },
          {
            "db": "JVN",
            "id": "JVNVU95413676",
            "trust": 2.4
          },
          {
            "db": "ICS CERT",
            "id": "ICSA-20-189-02",
            "trust": 2.0
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-006469",
            "trust": 1.4
          },
          {
            "db": "CNVD",
            "id": "CNVD-2020-46798",
            "trust": 0.6
          },
          {
            "db": "AUSCERT",
            "id": "ESB-2020.2312",
            "trust": 0.6
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202007-308",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2020-46798"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-006469"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202007-308"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-5600"
          }
        ]
      },
      "id": "VAR-202007-1228",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2020-46798"
          }
        ],
        "trust": 1.54642855
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "ICS"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2020-46798"
          }
        ]
      },
      "last_update_date": "2024-11-23T22:05:45.626000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "GOT2000\u30b7\u30ea\u30fc\u30ba\u306b\u304a\u3051\u308bTCP/IP\u30b9\u30bf\u30c3\u30af\u306e\u8907\u6570\u306e\u8106\u5f31\u6027",
            "trust": 0.8,
            "url": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-005.pdf"
          },
          {
            "title": "Patch for Resource management errors and vulnerabilities in multiple Mitsubishi Electric products (CNVD-2020-46798)",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/231124"
          },
          {
            "title": "Multiple Mitsubishi Electric Product resource management error vulnerability fixes",
            "trust": 0.6,
            "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=124077"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2020-46798"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-006469"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202007-308"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "NVD-CWE-noinfo",
            "trust": 1.0
          },
          {
            "problemtype": "CWE-476",
            "trust": 0.8
          },
          {
            "problemtype": "CWE-384",
            "trust": 0.8
          },
          {
            "problemtype": "CWE-119",
            "trust": 0.8
          },
          {
            "problemtype": "CWE-399",
            "trust": 0.8
          },
          {
            "problemtype": "CWE-88",
            "trust": 0.8
          },
          {
            "problemtype": "CWE-284",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-006469"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-5600"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.0,
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-189-02"
          },
          {
            "trust": 1.6,
            "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-005_en.pdf"
          },
          {
            "trust": 1.6,
            "url": "https://jvn.jp/en/vu/jvnvu95413676/index.html"
          },
          {
            "trust": 0.8,
            "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-5598"
          },
          {
            "trust": 0.8,
            "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-5599"
          },
          {
            "trust": 0.8,
            "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-5600"
          },
          {
            "trust": 0.8,
            "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-5595"
          },
          {
            "trust": 0.8,
            "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-5596"
          },
          {
            "trust": 0.8,
            "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-5597"
          },
          {
            "trust": 0.8,
            "url": "https://jvn.jp/vu/jvnvu95413676/index.html"
          },
          {
            "trust": 0.6,
            "url": "https://jvndb.jvn.jp/en/contents/2020/jvndb-2020-006469.html"
          },
          {
            "trust": 0.6,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2020-5600"
          },
          {
            "trust": 0.6,
            "url": "https://www.auscert.org.au/bulletins/esb-2020.2312/"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2020-46798"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-006469"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202007-308"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-5600"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2020-46798"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-006469"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202007-308"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-5600"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2020-08-19T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2020-46798"
          },
          {
            "date": "2020-07-09T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2020-006469"
          },
          {
            "date": "2020-07-07T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202007-308"
          },
          {
            "date": "2020-07-07T09:15:10.450000",
            "db": "NVD",
            "id": "CVE-2020-5600"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2020-08-19T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2020-46798"
          },
          {
            "date": "2020-07-09T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2020-006469"
          },
          {
            "date": "2020-07-15T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202007-308"
          },
          {
            "date": "2024-11-21T05:34:20.490000",
            "db": "NVD",
            "id": "CVE-2020-5600"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202007-308"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Made by Mitsubishi Electric  GOT2000 Of the series  TCP/IP Multiple vulnerabilities in functionality",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-006469"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "resource management error",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202007-308"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202007-1226

    Vulnerability from variot - Updated: 2024-11-23 22:05

    TCP/IP function included in the firmware of Mitsubishi Electric GOT2000 series (CoreOS with version -Y and earlier installed in GT27 Model, GT25 Model, and GT23 Model) contains an improper access control vulnerability, which may which may allow a remote attacker tobypass access restriction and stop the network functions of the products or execute a malicious program via a specially crafted packet. Mitsubishi Electric GT27, etc. are all a GOT2000 series graphical operation terminal of Japan's Mitsubishi Electric.

    CoreOS Y and earlier versions of Mitsubishi Electric GT27, GT25, and GT23 (GOT2000 series) have an access control error vulnerability. Attackers can use this vulnerability to access sensitive resources, causing denial of service and device crashes

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202007-1226",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "coreos",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "mitsubishielectric",
            "version": "y"
          },
          {
            "model": "gt23 model",
            "scope": null,
            "trust": 0.8,
            "vendor": "mitsubishi electric",
            "version": null
          },
          {
            "model": "gt25 model",
            "scope": null,
            "trust": 0.8,
            "vendor": "mitsubishi electric",
            "version": null
          },
          {
            "model": "gt27 model",
            "scope": null,
            "trust": 0.8,
            "vendor": "mitsubishi electric",
            "version": null
          },
          {
            "model": "electric gt27 model",
            "scope": null,
            "trust": 0.6,
            "vendor": "mitsubishi",
            "version": null
          },
          {
            "model": "electric gt25 model",
            "scope": null,
            "trust": 0.6,
            "vendor": "mitsubishi",
            "version": null
          },
          {
            "model": "electric gt23 model",
            "scope": null,
            "trust": 0.6,
            "vendor": "mitsubishi",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2020-46800"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-006469"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-5598"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "cpe_match": [
                  {
                    "cpe22Uri": "cpe:/o:mitsubishielectric:gt23_model",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:mitsubishielectric:gt25_model",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:mitsubishielectric:gt27_model",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-006469"
          }
        ]
      },
      "cve": "CVE-2020-5598",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "NONE",
                "baseScore": 5.0,
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 10.0,
                "id": "CVE-2020-5598",
                "impactScore": 2.9,
                "integrityImpact": "PARTIAL",
                "severity": "MEDIUM",
                "trust": 1.1,
                "vectorString": "AV:N/AC:L/Au:N/C:N/I:P/A:N",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "PARTIAL",
                "baseScore": 7.5,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2020-46800",
                "impactScore": 6.4,
                "integrityImpact": "PARTIAL",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "NONE",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "exploitabilityScore": 3.9,
                "id": "CVE-2020-5598",
                "impactScore": 3.6,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "IPA score",
                "availabilityImpact": "High",
                "baseScore": 9.8,
                "baseSeverity": "Critical",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "JVNDB-2020-006469",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2020-5598",
                "trust": 1.0,
                "value": "HIGH"
              },
              {
                "author": "IPA",
                "id": "JVNDB-2020-006469",
                "trust": 0.8,
                "value": "Critical"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2020-46800",
                "trust": 0.6,
                "value": "HIGH"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202007-307",
                "trust": 0.6,
                "value": "HIGH"
              },
              {
                "author": "VULMON",
                "id": "CVE-2020-5598",
                "trust": 0.1,
                "value": "MEDIUM"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2020-46800"
          },
          {
            "db": "VULMON",
            "id": "CVE-2020-5598"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-006469"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202007-307"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-5598"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "TCP/IP function included in the firmware of Mitsubishi Electric GOT2000 series (CoreOS with version -Y and earlier installed in GT27 Model, GT25 Model, and GT23 Model) contains an improper access control vulnerability, which may which may allow a remote attacker tobypass access restriction and stop the network functions of the products or execute a malicious program via a specially crafted packet. Mitsubishi Electric GT27, etc. are all a GOT2000 series graphical operation terminal of Japan\u0027s Mitsubishi Electric. \n\r\n\r\nCoreOS Y and earlier versions of Mitsubishi Electric GT27, GT25, and GT23 (GOT2000 series) have an access control error vulnerability. Attackers can use this vulnerability to access sensitive resources, causing denial of service and device crashes",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2020-5598"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-006469"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2020-46800"
          },
          {
            "db": "VULMON",
            "id": "CVE-2020-5598"
          }
        ],
        "trust": 2.25
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2020-5598",
            "trust": 3.1
          },
          {
            "db": "JVN",
            "id": "JVNVU95413676",
            "trust": 2.5
          },
          {
            "db": "ICS CERT",
            "id": "ICSA-20-189-02",
            "trust": 2.0
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-006469",
            "trust": 1.4
          },
          {
            "db": "CNVD",
            "id": "CNVD-2020-46800",
            "trust": 0.6
          },
          {
            "db": "AUSCERT",
            "id": "ESB-2020.2312",
            "trust": 0.6
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202007-307",
            "trust": 0.6
          },
          {
            "db": "VULMON",
            "id": "CVE-2020-5598",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2020-46800"
          },
          {
            "db": "VULMON",
            "id": "CVE-2020-5598"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-006469"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202007-307"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-5598"
          }
        ]
      },
      "id": "VAR-202007-1226",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2020-46800"
          }
        ],
        "trust": 1.54642855
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "ICS"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2020-46800"
          }
        ]
      },
      "last_update_date": "2024-11-23T22:05:45.595000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "GOT2000\u30b7\u30ea\u30fc\u30ba\u306b\u304a\u3051\u308bTCP/IP\u30b9\u30bf\u30c3\u30af\u306e\u8907\u6570\u306e\u8106\u5f31\u6027",
            "trust": 0.8,
            "url": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-005.pdf"
          },
          {
            "title": "Patch for Access control error vulnerabilities in multiple Mitsubishi Electric products",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/231115"
          },
          {
            "title": "Multiple Mitsubishi Electric Product security vulnerabilities",
            "trust": 0.6,
            "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=124076"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2020-46800"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-006469"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202007-307"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "NVD-CWE-noinfo",
            "trust": 1.0
          },
          {
            "problemtype": "CWE-476",
            "trust": 0.8
          },
          {
            "problemtype": "CWE-384",
            "trust": 0.8
          },
          {
            "problemtype": "CWE-119",
            "trust": 0.8
          },
          {
            "problemtype": "CWE-399",
            "trust": 0.8
          },
          {
            "problemtype": "CWE-88",
            "trust": 0.8
          },
          {
            "problemtype": "CWE-284",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-006469"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-5598"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.0,
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-189-02"
          },
          {
            "trust": 1.7,
            "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-005_en.pdf"
          },
          {
            "trust": 1.7,
            "url": "https://jvn.jp/en/vu/jvnvu95413676/index.html"
          },
          {
            "trust": 0.8,
            "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-5598"
          },
          {
            "trust": 0.8,
            "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-5599"
          },
          {
            "trust": 0.8,
            "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-5600"
          },
          {
            "trust": 0.8,
            "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-5595"
          },
          {
            "trust": 0.8,
            "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-5596"
          },
          {
            "trust": 0.8,
            "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-5597"
          },
          {
            "trust": 0.8,
            "url": "https://jvn.jp/vu/jvnvu95413676/index.html"
          },
          {
            "trust": 0.6,
            "url": "https://jvndb.jvn.jp/en/contents/2020/jvndb-2020-006469.html"
          },
          {
            "trust": 0.6,
            "url": "https://www.auscert.org.au/bulletins/esb-2020.2312/"
          },
          {
            "trust": 0.6,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2020-5598"
          },
          {
            "trust": 0.1,
            "url": "https://cwe.mitre.org/data/definitions/.html"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2020-46800"
          },
          {
            "db": "VULMON",
            "id": "CVE-2020-5598"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-006469"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202007-307"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-5598"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2020-46800"
          },
          {
            "db": "VULMON",
            "id": "CVE-2020-5598"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-006469"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202007-307"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-5598"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2020-08-19T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2020-46800"
          },
          {
            "date": "2020-07-07T00:00:00",
            "db": "VULMON",
            "id": "CVE-2020-5598"
          },
          {
            "date": "2020-07-09T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2020-006469"
          },
          {
            "date": "2020-07-07T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202007-307"
          },
          {
            "date": "2020-07-07T09:15:10.307000",
            "db": "NVD",
            "id": "CVE-2020-5598"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2020-08-19T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2020-46800"
          },
          {
            "date": "2021-07-21T00:00:00",
            "db": "VULMON",
            "id": "CVE-2020-5598"
          },
          {
            "date": "2020-07-09T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2020-006469"
          },
          {
            "date": "2020-07-15T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202007-307"
          },
          {
            "date": "2024-11-21T05:34:20.297000",
            "db": "NVD",
            "id": "CVE-2020-5598"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202007-307"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Made by Mitsubishi Electric  GOT2000 Of the series  TCP/IP Multiple vulnerabilities in functionality",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-006469"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "other",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202007-307"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-202007-1227

    Vulnerability from variot - Updated: 2024-11-23 22:05

    TCP/IP function included in the firmware of Mitsubishi Electric GOT2000 series (CoreOS with version -Y and earlier installed in GT27 Model, GT25 Model, and GT23 Model) contains an improper neutralization of argument delimiters in a command ('Argument Injection') vulnerability, which may allow a remote attacker to stop the network functions of the products or execute a malicious program via a specially crafted packet. Mitsubishi Electric GT27, etc. are all a GOT2000 series graphical operation terminal of Japan's Mitsubishi Electric.

    CoreOS Y and previous versions in Mitsubishi Electric GT27, GT25 and GT23 (GOT2000 series) have an injection vulnerability, which can be exploited by attackers to cause a denial of service

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-202007-1227",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "coreos",
            "scope": "lte",
            "trust": 1.0,
            "vendor": "mitsubishielectric",
            "version": "y"
          },
          {
            "model": "gt23 model",
            "scope": null,
            "trust": 0.8,
            "vendor": "mitsubishi electric",
            "version": null
          },
          {
            "model": "gt25 model",
            "scope": null,
            "trust": 0.8,
            "vendor": "mitsubishi electric",
            "version": null
          },
          {
            "model": "gt27 model",
            "scope": null,
            "trust": 0.8,
            "vendor": "mitsubishi electric",
            "version": null
          },
          {
            "model": "electric gt27 model",
            "scope": null,
            "trust": 0.6,
            "vendor": "mitsubishi",
            "version": null
          },
          {
            "model": "electric gt25 model",
            "scope": null,
            "trust": 0.6,
            "vendor": "mitsubishi",
            "version": null
          },
          {
            "model": "electric gt23 model",
            "scope": null,
            "trust": 0.6,
            "vendor": "mitsubishi",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2020-46799"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-006469"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-5599"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "cpe_match": [
                  {
                    "cpe22Uri": "cpe:/o:mitsubishielectric:gt23_model",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:mitsubishielectric:gt25_model",
                    "vulnerable": true
                  },
                  {
                    "cpe22Uri": "cpe:/o:mitsubishielectric:gt27_model",
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-006469"
          }
        ]
      },
      "cve": "CVE-2020-5599",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "nvd@nist.gov",
                "availabilityImpact": "COMPLETE",
                "baseScore": 10.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 10.0,
                "id": "CVE-2020-5599",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 1.0,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "CNVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 10.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 10.0,
                "id": "CNVD-2020-46799",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.6,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "nvd@nist.gov",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "id": "CVE-2020-5599",
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "IPA score",
                "availabilityImpact": "High",
                "baseScore": 9.8,
                "baseSeverity": "Critical",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "JVNDB-2020-006469",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "nvd@nist.gov",
                "id": "CVE-2020-5599",
                "trust": 1.0,
                "value": "CRITICAL"
              },
              {
                "author": "IPA",
                "id": "JVNDB-2020-006469",
                "trust": 0.8,
                "value": "Critical"
              },
              {
                "author": "CNVD",
                "id": "CNVD-2020-46799",
                "trust": 0.6,
                "value": "HIGH"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-202007-309",
                "trust": 0.6,
                "value": "CRITICAL"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2020-46799"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-006469"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202007-309"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-5599"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "TCP/IP function included in the firmware of Mitsubishi Electric GOT2000 series (CoreOS with version -Y and earlier installed in GT27 Model, GT25 Model, and GT23 Model) contains an improper neutralization of argument delimiters in a command (\u0027Argument Injection\u0027) vulnerability, which may allow a remote attacker to stop the network functions of the products or execute a malicious program via a specially crafted packet. Mitsubishi Electric GT27, etc. are all a GOT2000 series graphical operation terminal of Japan\u0027s Mitsubishi Electric. \n\r\n\r\nCoreOS Y and previous versions in Mitsubishi Electric GT27, GT25 and GT23 (GOT2000 series) have an injection vulnerability, which can be exploited by attackers to cause a denial of service",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2020-5599"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-006469"
          },
          {
            "db": "CNVD",
            "id": "CNVD-2020-46799"
          }
        ],
        "trust": 2.16
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2020-5599",
            "trust": 3.0
          },
          {
            "db": "JVN",
            "id": "JVNVU95413676",
            "trust": 2.4
          },
          {
            "db": "ICS CERT",
            "id": "ICSA-20-189-02",
            "trust": 2.0
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-006469",
            "trust": 1.4
          },
          {
            "db": "CNVD",
            "id": "CNVD-2020-46799",
            "trust": 0.6
          },
          {
            "db": "AUSCERT",
            "id": "ESB-2020.2312",
            "trust": 0.6
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202007-309",
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2020-46799"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-006469"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202007-309"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-5599"
          }
        ]
      },
      "id": "VAR-202007-1227",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2020-46799"
          }
        ],
        "trust": 1.54642855
      },
      "iot_taxonomy": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "category": [
              "ICS"
            ],
            "sub_category": null,
            "trust": 0.6
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2020-46799"
          }
        ]
      },
      "last_update_date": "2024-11-23T22:05:45.546000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "GOT2000\u30b7\u30ea\u30fc\u30ba\u306b\u304a\u3051\u308bTCP/IP\u30b9\u30bf\u30c3\u30af\u306e\u8907\u6570\u306e\u8106\u5f31\u6027",
            "trust": 0.8,
            "url": "https://www.mitsubishielectric.co.jp/psirt/vulnerability/pdf/2020-005.pdf"
          },
          {
            "title": "Patch for Injection vulnerabilities in many Mitsubishi Electric products",
            "trust": 0.6,
            "url": "https://www.cnvd.org.cn/patchInfo/show/231121"
          },
          {
            "title": "Multiple Mitsubishi Electric Fixing measures for product injection vulnerabilities",
            "trust": 0.6,
            "url": "http://www.cnnvd.org.cn/web/xxk/bdxqById.tag?id=124078"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2020-46799"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-006469"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202007-309"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-88",
            "trust": 1.8
          },
          {
            "problemtype": "CWE-476",
            "trust": 0.8
          },
          {
            "problemtype": "CWE-384",
            "trust": 0.8
          },
          {
            "problemtype": "CWE-119",
            "trust": 0.8
          },
          {
            "problemtype": "CWE-399",
            "trust": 0.8
          },
          {
            "problemtype": "CWE-284",
            "trust": 0.8
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-006469"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-5599"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.0,
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-189-02"
          },
          {
            "trust": 1.6,
            "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2020-005_en.pdf"
          },
          {
            "trust": 1.6,
            "url": "https://jvn.jp/en/vu/jvnvu95413676/index.html"
          },
          {
            "trust": 0.8,
            "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-5598"
          },
          {
            "trust": 0.8,
            "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-5599"
          },
          {
            "trust": 0.8,
            "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-5600"
          },
          {
            "trust": 0.8,
            "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-5595"
          },
          {
            "trust": 0.8,
            "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-5596"
          },
          {
            "trust": 0.8,
            "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-5597"
          },
          {
            "trust": 0.8,
            "url": "https://jvn.jp/vu/jvnvu95413676/index.html"
          },
          {
            "trust": 0.6,
            "url": "https://jvndb.jvn.jp/en/contents/2020/jvndb-2020-006469.html"
          },
          {
            "trust": 0.6,
            "url": "https://www.auscert.org.au/bulletins/esb-2020.2312/"
          },
          {
            "trust": 0.6,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2020-5599"
          }
        ],
        "sources": [
          {
            "db": "CNVD",
            "id": "CNVD-2020-46799"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-006469"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202007-309"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-5599"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "CNVD",
            "id": "CNVD-2020-46799"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-006469"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-202007-309"
          },
          {
            "db": "NVD",
            "id": "CVE-2020-5599"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2020-08-19T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2020-46799"
          },
          {
            "date": "2020-07-09T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2020-006469"
          },
          {
            "date": "2020-07-07T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202007-309"
          },
          {
            "date": "2020-07-07T09:15:10.370000",
            "db": "NVD",
            "id": "CVE-2020-5599"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2020-08-19T00:00:00",
            "db": "CNVD",
            "id": "CNVD-2020-46799"
          },
          {
            "date": "2020-07-09T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2020-006469"
          },
          {
            "date": "2020-07-15T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-202007-309"
          },
          {
            "date": "2024-11-21T05:34:20.397000",
            "db": "NVD",
            "id": "CVE-2020-5599"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202007-309"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Made by Mitsubishi Electric  GOT2000 Of the series  TCP/IP Multiple vulnerabilities in functionality",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2020-006469"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "injection",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-202007-309"
          }
        ],
        "trust": 0.6
      }
    }

    JVNDB-2020-006469

    Vulnerability from jvndb - Published: 2020-07-09 15:46 - Updated:2020-07-09 15:46
    Severity
    Summary
    Multiple vulnerabilities in TCP/IP function on Mitsubishi Electric GOT2000 series
    Details
    TCP/IP function included in the firmware of Mitsubishi Electric GOT2000 series GT27, GT25, and GT23 contains multiple vulnerabilities listed below. * Improper Restriction of Operations within the Bounds of a Memory Buffer (CWE-119) - CVE-2020-5595 * Session Fixation (CWE-384) - CVE-2020-5596 * NULL Pointer Dereference (CWE-476) - CVE-2020-5597 * Improper Access Control (CWE-284) - CVE-2020-5598 * Improper Neutralization of Argument Delimiters in a Command ('Argument Injection') (CWE-88) - CVE-2020-5599 * Resource Management Errors (CWE-399) - CVE-2020-5560
    Show details on JVN DB website

    {
      "@rdf:about": "https://jvndb.jvn.jp/en/contents/2020/JVNDB-2020-006469.html",
      "dc:date": "2020-07-09T15:46+09:00",
      "dcterms:issued": "2020-07-09T15:46+09:00",
      "dcterms:modified": "2020-07-09T15:46+09:00",
      "description": "TCP/IP function included in the firmware of Mitsubishi Electric GOT2000 series GT27, GT25, and GT23 contains multiple vulnerabilities listed below. \r\n\r\n* Improper Restriction of Operations within the Bounds of a Memory Buffer (CWE-119) - CVE-2020-5595\r\n* Session Fixation (CWE-384) - CVE-2020-5596\r\n* NULL Pointer Dereference (CWE-476) - CVE-2020-5597\r\n* Improper Access Control (CWE-284) - CVE-2020-5598\r\n* Improper Neutralization of Argument Delimiters in a Command (\u0027Argument Injection\u0027) (CWE-88) - CVE-2020-5599\r\n* Resource Management Errors (CWE-399) - CVE-2020-5560",
      "link": "https://jvndb.jvn.jp/en/contents/2020/JVNDB-2020-006469.html",
      "sec:cpe": [
        {
          "#text": "cpe:/o:mitsubishielectric:gt23_model",
          "@product": "GT23 Model",
          "@vendor": "Mitsubishi Electric",
          "@version": "2.2"
        },
        {
          "#text": "cpe:/o:mitsubishielectric:gt25_model",
          "@product": "GT25 Model",
          "@vendor": "Mitsubishi Electric",
          "@version": "2.2"
        },
        {
          "#text": "cpe:/o:mitsubishielectric:gt27_model",
          "@product": "GT27 Model",
          "@vendor": "Mitsubishi Electric",
          "@version": "2.2"
        }
      ],
      "sec:cvss": [
        {
          "@score": "10.0",
          "@severity": "High",
          "@type": "Base",
          "@vector": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
          "@version": "2.0"
        },
        {
          "@score": "9.8",
          "@severity": "Critical",
          "@type": "Base",
          "@vector": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
          "@version": "3.0"
        }
      ],
      "sec:identifier": "JVNDB-2020-006469",
      "sec:references": [
        {
          "#text": "https://jvn.jp/en/vu/JVNVU95413676/index.html",
          "@id": "JVNVU#95413676",
          "@source": "JVN"
        },
        {
          "#text": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=CVE-2020-5595",
          "@id": "CVE-2020-5595",
          "@source": "CVE"
        },
        {
          "#text": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=CVE-2020-5596",
          "@id": "CVE-2020-5596",
          "@source": "CVE"
        },
        {
          "#text": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=CVE-2020-5597",
          "@id": "CVE-2020-5597",
          "@source": "CVE"
        },
        {
          "#text": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=CVE-2020-5598",
          "@id": "CVE-2020-5598",
          "@source": "CVE"
        },
        {
          "#text": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=CVE-2020-5599",
          "@id": "CVE-2020-5599",
          "@source": "CVE"
        },
        {
          "#text": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=CVE-2020-5600",
          "@id": "CVE-2020-5600",
          "@source": "CVE"
        },
        {
          "#text": "https://nvd.nist.gov/vuln/detail/CVE-2020-5595",
          "@id": "CVE-2020-5595",
          "@source": "NVD"
        },
        {
          "#text": "https://nvd.nist.gov/vuln/detail/CVE-2020-5596",
          "@id": "CVE-2020-5596",
          "@source": "NVD"
        },
        {
          "#text": "https://nvd.nist.gov/vuln/detail/CVE-2020-5597",
          "@id": "CVE-2020-5597",
          "@source": "NVD"
        },
        {
          "#text": "https://nvd.nist.gov/vuln/detail/CVE-2020-5598",
          "@id": "CVE-2020-5598",
          "@source": "NVD"
        },
        {
          "#text": "https://nvd.nist.gov/vuln/detail/CVE-2020-5599",
          "@id": "CVE-2020-5599",
          "@source": "NVD"
        },
        {
          "#text": "https://nvd.nist.gov/vuln/detail/CVE-2020-5600",
          "@id": "CVE-2020-5600",
          "@source": "NVD"
        },
        {
          "#text": "https://us-cert.cisa.gov/ics/advisories/icsa-20-189-02",
          "@id": "ICSA-20-189-02",
          "@source": "ICS-CERT ADVISORY"
        },
        {
          "#text": "https://www.ipa.go.jp/en/security/vulnerabilities/cwe.html",
          "@id": "CWE-119",
          "@title": "Buffer Errors(CWE-119)"
        },
        {
          "#text": "https://cwe.mitre.org/data/definitions/284.html",
          "@id": "CWE-284",
          "@title": "Improper Access Control(CWE-284)"
        },
        {
          "#text": "https://cwe.mitre.org/data/definitions/384.html",
          "@id": "CWE-384",
          "@title": "Session Fixation(CWE-384)"
        },
        {
          "#text": "https://www.ipa.go.jp/en/security/vulnerabilities/cwe.html",
          "@id": "CWE-399",
          "@title": "Resource Management Errors(CWE-399)"
        },
        {
          "#text": "http://cwe.mitre.org/data/definitions/476.html",
          "@id": "CWE-476",
          "@title": "NULL Pointer Dereference(CWE-476)"
        },
        {
          "#text": "https://cwe.mitre.org/data/definitions/88.html",
          "@id": "CWE-88",
          "@title": "Argument Injection or Modification(CWE-88)"
        }
      ],
      "title": "Multiple vulnerabilities in TCP/IP function on Mitsubishi Electric GOT2000 series"
    }