Search

Find a vulnerability

Search criteria

    2 vulnerabilities found for FDS-SNMP101 by Frauscher

    CVE-2025-3705 (GCVE-0-2025-3705)

    Vulnerability from nvd – Published: 2025-07-07 09:20 – Updated: 2025-07-07 17:34
    VLAI
    Title
    OS Command Injection via USB Config Load
    Summary
    A physical attacker with no privileges can gain full control of the affected device due to improper neutralization of special elements used in an OS Command ('OS Command Injection') when loading a config file from a USB drive.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    Assigner
    References
    Impacted products
    Vendor Product Version
    Frauscher FDS102 Affected: 0.0.0 , < v2.13.3 (semver)
    Create a notification for this product.
    Frauscher FDS101 Affected: 0.0.0 , ≤ v1.4.25 (semver)
    Create a notification for this product.
    Frauscher FDS-SNMP101 Affected: 0.0.0 , ≤ v.2.3.9 (semver)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-3705",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-07-07T17:33:44.109898Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-07-07T17:34:15.583Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "FDS102",
              "vendor": "Frauscher",
              "versions": [
                {
                  "lessThan": "v2.13.3",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "FDS101",
              "vendor": "Frauscher",
              "versions": [
                {
                  "lessThanOrEqual": "v1.4.25",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "FDS-SNMP101",
              "vendor": "Frauscher",
              "versions": [
                {
                  "lessThanOrEqual": "v.2.3.9",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "A physical attacker with no privileges can gain full control of the affected device due to improper neutralization of special elements used in an OS Command (\u0027OS Command Injection\u0027) when loading a config file from a USB drive."
                }
              ],
              "value": "A physical attacker with no privileges can gain full control of the affected device due to improper neutralization of special elements used in an OS Command (\u0027OS Command Injection\u0027) when loading a config file from a USB drive."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "PHYSICAL",
                "availabilityImpact": "HIGH",
                "baseScore": 6.8,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-07-07T09:20:03.263Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://certvde.com/en/advisories/VDE-2025-030"
            }
          ],
          "source": {
            "advisory": "VDE-2025-030",
            "defect": [
              "CERT@VDE#641766"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "OS Command Injection via USB Config Load",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2025-3705",
        "datePublished": "2025-07-07T09:20:03.263Z",
        "dateReserved": "2025-04-16T06:43:57.178Z",
        "dateUpdated": "2025-07-07T17:34:15.583Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-3705 (GCVE-0-2025-3705)

    Vulnerability from cvelistv5 – Published: 2025-07-07 09:20 – Updated: 2025-07-07 17:34
    VLAI
    Title
    OS Command Injection via USB Config Load
    Summary
    A physical attacker with no privileges can gain full control of the affected device due to improper neutralization of special elements used in an OS Command ('OS Command Injection') when loading a config file from a USB drive.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    Assigner
    References
    Impacted products
    Vendor Product Version
    Frauscher FDS102 Affected: 0.0.0 , < v2.13.3 (semver)
    Create a notification for this product.
    Frauscher FDS101 Affected: 0.0.0 , ≤ v1.4.25 (semver)
    Create a notification for this product.
    Frauscher FDS-SNMP101 Affected: 0.0.0 , ≤ v.2.3.9 (semver)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-3705",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-07-07T17:33:44.109898Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-07-07T17:34:15.583Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "FDS102",
              "vendor": "Frauscher",
              "versions": [
                {
                  "lessThan": "v2.13.3",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "FDS101",
              "vendor": "Frauscher",
              "versions": [
                {
                  "lessThanOrEqual": "v1.4.25",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "FDS-SNMP101",
              "vendor": "Frauscher",
              "versions": [
                {
                  "lessThanOrEqual": "v.2.3.9",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "A physical attacker with no privileges can gain full control of the affected device due to improper neutralization of special elements used in an OS Command (\u0027OS Command Injection\u0027) when loading a config file from a USB drive."
                }
              ],
              "value": "A physical attacker with no privileges can gain full control of the affected device due to improper neutralization of special elements used in an OS Command (\u0027OS Command Injection\u0027) when loading a config file from a USB drive."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "PHYSICAL",
                "availabilityImpact": "HIGH",
                "baseScore": 6.8,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-07-07T09:20:03.263Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://certvde.com/en/advisories/VDE-2025-030"
            }
          ],
          "source": {
            "advisory": "VDE-2025-030",
            "defect": [
              "CERT@VDE#641766"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "OS Command Injection via USB Config Load",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2025-3705",
        "datePublished": "2025-07-07T09:20:03.263Z",
        "dateReserved": "2025-04-16T06:43:57.178Z",
        "dateUpdated": "2025-07-07T17:34:15.583Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }