    CVE-2025-34029 (GCVE-0-2025-34029)

    Vulnerability from nvd – Published: 2025-06-20 18:38 – Updated: 2026-05-14 02:07 X_Known Exploited Vulnerability
    VLAI
    Title
    Edimax EW-7438RPn Mini OS Command Injection via syscmd.asp
    Summary
    An OS command injection vulnerability exists in the Edimax EW-7438RPn Mini firmware version 1.13 and prior via the syscmd.asp form handler. The /goform/formSysCmd endpoint exposes a system command interface through the sysCmd parameter. A remote authenticated attacker can submit arbitrary shell commands directly, resulting in command execution as the root user. Exploitation evidence was observed by the Shadowserver Foundation on 2024-09-14 UTC.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    Assigner
    Impacted products
    Vendor Product Version
    Edimax Edimax EW-7438RPn Mini Affected: 0 , ≤ 1.13 (custom)
    Create a notification for this product.
    Date Public
    2020-04-24 00:00
    Credits
    Besim Altinok
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-34029",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-06-23T20:41:13.971995Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-06-23T20:41:36.630Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "modules": [
                "Web Management Interface (syscmd.asp system command interface)"
              ],
              "product": "Edimax EW-7438RPn Mini",
              "vendor": "Edimax",
              "versions": [
                {
                  "lessThanOrEqual": "1.13",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "cpeApplicability": [
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:h:edimax:ew-7438rpn_mini_v2:*:*:*:*:*:*:*:*",
                      "versionEndIncluding": "1.13",
                      "versionStartIncluding": "0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Besim Altinok"
            }
          ],
          "datePublic": "2020-04-24T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "An OS command injection vulnerability exists in the Edimax EW-7438RPn Mini firmware version 1.13 and prior via the syscmd.asp form handler. The /goform/formSysCmd endpoint exposes a system command interface through the sysCmd parameter. A remote authenticated attacker can submit arbitrary shell commands directly, resulting in command execution as the root user.\u0026nbsp;Exploitation evidence was observed by the Shadowserver Foundation on 2024-09-14 UTC."
                }
              ],
              "value": "An OS command injection vulnerability exists in the Edimax EW-7438RPn Mini firmware version 1.13 and prior via the syscmd.asp form handler. The /goform/formSysCmd endpoint exposes a system command interface through the sysCmd parameter. A remote authenticated attacker can submit arbitrary shell commands directly, resulting in command execution as the root user.\u00a0Exploitation evidence was observed by the Shadowserver Foundation on 2024-09-14 UTC."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-88",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-88 OS Command Injection"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 9.4,
                "baseSeverity": "CRITICAL",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "HIGH",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-05-14T02:07:23.605Z",
            "orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
            "shortName": "VulnCheck"
          },
          "references": [
            {
              "tags": [
                "product"
              ],
              "url": "https://www.edimax.com/edimax/merchandise/merchandise_detail/data/edimax/global/wi-fi_range_extenders_n300/ew-7438rpn_mini/"
            },
            {
              "tags": [
                "third-party-advisory",
                "exploit"
              ],
              "url": "https://www.exploit-db.com/exploits/48377"
            },
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://www.broadcom.com/support/security-center/attacksignatures/detail?asid=32163"
            },
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vulncheck.com/advisories/edimax-ew-7438rpn-command-injections"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "tags": [
            "x_known-exploited-vulnerability"
          ],
          "title": "Edimax EW-7438RPn Mini OS Command Injection via syscmd.asp",
          "x_generator": {
            "engine": "vulncheck"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
        "assignerShortName": "VulnCheck",
        "cveId": "CVE-2025-34029",
        "datePublished": "2025-06-20T18:38:15.689Z",
        "dateReserved": "2025-04-15T19:15:22.546Z",
        "dateUpdated": "2026-05-14T02:07:23.605Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-34024 (GCVE-0-2025-34024)

    Vulnerability from nvd – Published: 2025-06-20 18:38 – Updated: 2026-05-14 02:07 X_Known Exploited Vulnerability
    VLAI
    Title
    Edimax EW-7438RPn Mini OS Command Injection via mp.asp
    Summary
    An OS command injection vulnerability exists in the Edimax EW-7438RPn firmware version 1.13 and prior via the mp.asp form handler. The /goform/mp endpoint improperly handles user-supplied input to the command parameter. An authenticated attacker can inject shell commands using shell metacharacters to achieve arbitrary command execution as the root user. Exploitation evidence was observed by the Shadowserver Foundation on 2024-09-14 UTC.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    Assigner
    Impacted products
    Vendor Product Version
    Edimax Edimax EW-7438RPn Mini Affected: 0 , ≤ 1.13 (custom)
    Create a notification for this product.
    Date Public
    2020-04-24 00:00
    Credits
    Besim Altinok
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-34024",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-06-23T20:39:27.231637Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-06-23T20:40:00.795Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "modules": [
                "Web Management Interface (mp.asp command handler)"
              ],
              "product": "Edimax EW-7438RPn Mini",
              "vendor": "Edimax",
              "versions": [
                {
                  "lessThanOrEqual": "1.13",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "cpeApplicability": [
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:h:edimax:ew-7438rpn_mini_v2:*:*:*:*:*:*:*:*",
                      "versionEndIncluding": "1.13",
                      "versionStartIncluding": "0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Besim Altinok"
            }
          ],
          "datePublic": "2020-04-24T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "An OS command injection vulnerability exists in the Edimax EW-7438RPn firmware version 1.13 and prior via the mp.asp form handler. The /goform/mp endpoint improperly handles user-supplied input to the command parameter. An authenticated attacker can inject shell commands using shell metacharacters to achieve arbitrary command execution as the root user. Exploitation evidence was observed by the Shadowserver Foundation on 2024-09-14 UTC."
                }
              ],
              "value": "An OS command injection vulnerability exists in the Edimax EW-7438RPn firmware version 1.13 and prior via the mp.asp form handler. The /goform/mp endpoint improperly handles user-supplied input to the command parameter. An authenticated attacker can inject shell commands using shell metacharacters to achieve arbitrary command execution as the root user. Exploitation evidence was observed by the Shadowserver Foundation on 2024-09-14 UTC."
            }
          ],
          "exploits": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Known exploited vulnerability"
                }
              ],
              "value": "Known exploited vulnerability"
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-88",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-88 OS Command Injection"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 9.4,
                "baseSeverity": "CRITICAL",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "HIGH",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-05-14T02:07:22.672Z",
            "orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
            "shortName": "VulnCheck"
          },
          "references": [
            {
              "tags": [
                "product"
              ],
              "url": "https://www.edimax.com/edimax/merchandise/merchandise_detail/data/edimax/global/wi-fi_range_extenders_n300/ew-7438rpn_mini/"
            },
            {
              "tags": [
                "third-party-advisory",
                "exploit"
              ],
              "url": "https://www.exploit-db.com/exploits/48377"
            },
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://www.broadcom.com/support/security-center/attacksignatures/detail?asid=32163"
            },
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vulncheck.com/advisories/edimax-ew-7438rpn-command-injections"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "tags": [
            "x_known-exploited-vulnerability"
          ],
          "title": "Edimax EW-7438RPn Mini OS Command Injection via mp.asp",
          "x_generator": {
            "engine": "vulncheck"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
        "assignerShortName": "VulnCheck",
        "cveId": "CVE-2025-34024",
        "datePublished": "2025-06-20T18:38:02.885Z",
        "dateReserved": "2025-04-15T19:15:22.545Z",
        "dateUpdated": "2026-05-14T02:07:22.672Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-34029 (GCVE-0-2025-34029)

    Vulnerability from cvelistv5 – Published: 2025-06-20 18:38 – Updated: 2026-05-14 02:07 X_Known Exploited Vulnerability
    VLAI
    Title
    Edimax EW-7438RPn Mini OS Command Injection via syscmd.asp
    Summary
    An OS command injection vulnerability exists in the Edimax EW-7438RPn Mini firmware version 1.13 and prior via the syscmd.asp form handler. The /goform/formSysCmd endpoint exposes a system command interface through the sysCmd parameter. A remote authenticated attacker can submit arbitrary shell commands directly, resulting in command execution as the root user. Exploitation evidence was observed by the Shadowserver Foundation on 2024-09-14 UTC.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    Assigner
    Impacted products
    Vendor Product Version
    Edimax Edimax EW-7438RPn Mini Affected: 0 , ≤ 1.13 (custom)
    Create a notification for this product.
    Date Public
    2020-04-24 00:00
    Credits
    Besim Altinok
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-34029",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-06-23T20:41:13.971995Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-06-23T20:41:36.630Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "modules": [
                "Web Management Interface (syscmd.asp system command interface)"
              ],
              "product": "Edimax EW-7438RPn Mini",
              "vendor": "Edimax",
              "versions": [
                {
                  "lessThanOrEqual": "1.13",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "cpeApplicability": [
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:h:edimax:ew-7438rpn_mini_v2:*:*:*:*:*:*:*:*",
                      "versionEndIncluding": "1.13",
                      "versionStartIncluding": "0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Besim Altinok"
            }
          ],
          "datePublic": "2020-04-24T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "An OS command injection vulnerability exists in the Edimax EW-7438RPn Mini firmware version 1.13 and prior via the syscmd.asp form handler. The /goform/formSysCmd endpoint exposes a system command interface through the sysCmd parameter. A remote authenticated attacker can submit arbitrary shell commands directly, resulting in command execution as the root user.\u0026nbsp;Exploitation evidence was observed by the Shadowserver Foundation on 2024-09-14 UTC."
                }
              ],
              "value": "An OS command injection vulnerability exists in the Edimax EW-7438RPn Mini firmware version 1.13 and prior via the syscmd.asp form handler. The /goform/formSysCmd endpoint exposes a system command interface through the sysCmd parameter. A remote authenticated attacker can submit arbitrary shell commands directly, resulting in command execution as the root user.\u00a0Exploitation evidence was observed by the Shadowserver Foundation on 2024-09-14 UTC."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-88",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-88 OS Command Injection"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 9.4,
                "baseSeverity": "CRITICAL",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "HIGH",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-05-14T02:07:23.605Z",
            "orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
            "shortName": "VulnCheck"
          },
          "references": [
            {
              "tags": [
                "product"
              ],
              "url": "https://www.edimax.com/edimax/merchandise/merchandise_detail/data/edimax/global/wi-fi_range_extenders_n300/ew-7438rpn_mini/"
            },
            {
              "tags": [
                "third-party-advisory",
                "exploit"
              ],
              "url": "https://www.exploit-db.com/exploits/48377"
            },
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://www.broadcom.com/support/security-center/attacksignatures/detail?asid=32163"
            },
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vulncheck.com/advisories/edimax-ew-7438rpn-command-injections"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "tags": [
            "x_known-exploited-vulnerability"
          ],
          "title": "Edimax EW-7438RPn Mini OS Command Injection via syscmd.asp",
          "x_generator": {
            "engine": "vulncheck"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
        "assignerShortName": "VulnCheck",
        "cveId": "CVE-2025-34029",
        "datePublished": "2025-06-20T18:38:15.689Z",
        "dateReserved": "2025-04-15T19:15:22.546Z",
        "dateUpdated": "2026-05-14T02:07:23.605Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-34024 (GCVE-0-2025-34024)

    Vulnerability from cvelistv5 – Published: 2025-06-20 18:38 – Updated: 2026-05-14 02:07 X_Known Exploited Vulnerability
    VLAI
    Title
    Edimax EW-7438RPn Mini OS Command Injection via mp.asp
    Summary
    An OS command injection vulnerability exists in the Edimax EW-7438RPn firmware version 1.13 and prior via the mp.asp form handler. The /goform/mp endpoint improperly handles user-supplied input to the command parameter. An authenticated attacker can inject shell commands using shell metacharacters to achieve arbitrary command execution as the root user. Exploitation evidence was observed by the Shadowserver Foundation on 2024-09-14 UTC.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
    Assigner
    Impacted products
    Vendor Product Version
    Edimax Edimax EW-7438RPn Mini Affected: 0 , ≤ 1.13 (custom)
    Create a notification for this product.
    Date Public
    2020-04-24 00:00
    Credits
    Besim Altinok
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-34024",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-06-23T20:39:27.231637Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-06-23T20:40:00.795Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "modules": [
                "Web Management Interface (mp.asp command handler)"
              ],
              "product": "Edimax EW-7438RPn Mini",
              "vendor": "Edimax",
              "versions": [
                {
                  "lessThanOrEqual": "1.13",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "cpeApplicability": [
            {
              "nodes": [
                {
                  "cpeMatch": [
                    {
                      "criteria": "cpe:2.3:h:edimax:ew-7438rpn_mini_v2:*:*:*:*:*:*:*:*",
                      "versionEndIncluding": "1.13",
                      "versionStartIncluding": "0",
                      "vulnerable": true
                    }
                  ],
                  "negate": false,
                  "operator": "OR"
                }
              ],
              "operator": "OR"
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Besim Altinok"
            }
          ],
          "datePublic": "2020-04-24T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "An OS command injection vulnerability exists in the Edimax EW-7438RPn firmware version 1.13 and prior via the mp.asp form handler. The /goform/mp endpoint improperly handles user-supplied input to the command parameter. An authenticated attacker can inject shell commands using shell metacharacters to achieve arbitrary command execution as the root user. Exploitation evidence was observed by the Shadowserver Foundation on 2024-09-14 UTC."
                }
              ],
              "value": "An OS command injection vulnerability exists in the Edimax EW-7438RPn firmware version 1.13 and prior via the mp.asp form handler. The /goform/mp endpoint improperly handles user-supplied input to the command parameter. An authenticated attacker can inject shell commands using shell metacharacters to achieve arbitrary command execution as the root user. Exploitation evidence was observed by the Shadowserver Foundation on 2024-09-14 UTC."
            }
          ],
          "exploits": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Known exploited vulnerability"
                }
              ],
              "value": "Known exploited vulnerability"
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-88",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-88 OS Command Injection"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 9.4,
                "baseSeverity": "CRITICAL",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "HIGH",
                "subIntegrityImpact": "HIGH",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-05-14T02:07:22.672Z",
            "orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
            "shortName": "VulnCheck"
          },
          "references": [
            {
              "tags": [
                "product"
              ],
              "url": "https://www.edimax.com/edimax/merchandise/merchandise_detail/data/edimax/global/wi-fi_range_extenders_n300/ew-7438rpn_mini/"
            },
            {
              "tags": [
                "third-party-advisory",
                "exploit"
              ],
              "url": "https://www.exploit-db.com/exploits/48377"
            },
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://www.broadcom.com/support/security-center/attacksignatures/detail?asid=32163"
            },
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vulncheck.com/advisories/edimax-ew-7438rpn-command-injections"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "tags": [
            "x_known-exploited-vulnerability"
          ],
          "title": "Edimax EW-7438RPn Mini OS Command Injection via mp.asp",
          "x_generator": {
            "engine": "vulncheck"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
        "assignerShortName": "VulnCheck",
        "cveId": "CVE-2025-34024",
        "datePublished": "2025-06-20T18:38:02.885Z",
        "dateReserved": "2025-04-15T19:15:22.545Z",
        "dateUpdated": "2026-05-14T02:07:22.672Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }