Search

Find a vulnerability

Search criteria

    2 vulnerabilities found for DS-7604NXI-K1/4P by Hikvision

    CVE-2024-29948 (GCVE-0-2024-29948)

    Vulnerability from nvd – Published: 2024-04-02 11:07 – Updated: 2024-11-06 21:00
    VLAI
    Summary
    There is an out-of-bounds read vulnerability in some Hikvision NVRs. An authenticated attacker could exploit this vulnerability by sending specially crafted messages to a vulnerable device, causing a service abnormality.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    Impacted products
    Vendor Product Version
    Hikvision DS-7604NXI-K1/4P Affected: V4.76.005 build231012 and the versions prior to it
    Create a notification for this product.
    Credits
    KITRI BoB 12th
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-29948",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-08-15T18:51:42.752876Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-125",
                    "description": "CWE-125 Out-of-bounds Read",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-11-06T21:00:14.957Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T01:17:58.501Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.hikvision.com/en/support/cybersecurity/security-advisory/security-vulnerabilities-in-hikvision-nvr-devices/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "affected",
              "product": "DS-7604NXI-K1/4P",
              "vendor": "Hikvision",
              "versions": [
                {
                  "status": "affected",
                  "version": "V4.76.005 build231012 and the versions prior to it"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "KITRI BoB 12th"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "There is an out-of-bounds read vulnerability in some Hikvision NVRs. An authenticated attacker could exploit this vulnerability by sending specially crafted messages to a vulnerable device, causing a service abnormality."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "LOW",
                "baseScore": 3.8,
                "baseSeverity": "LOW",
                "confidentialityImpact": "LOW",
                "integrityImpact": "NONE",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:N/A:L",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-04-02T11:07:04.983Z",
            "orgId": "da451dce-859b-4e51-8b87-9c8b60d19b32",
            "shortName": "hikvision"
          },
          "references": [
            {
              "url": "https://www.hikvision.com/en/support/cybersecurity/security-advisory/security-vulnerabilities-in-hikvision-nvr-devices/"
            }
          ],
          "x_generator": {
            "engine": "cveClient/1.0.15"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "da451dce-859b-4e51-8b87-9c8b60d19b32",
        "assignerShortName": "hikvision",
        "cveId": "CVE-2024-29948",
        "datePublished": "2024-04-02T11:07:04.983Z",
        "dateReserved": "2024-03-22T02:34:04.957Z",
        "dateUpdated": "2024-11-06T21:00:14.957Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-29948 (GCVE-0-2024-29948)

    Vulnerability from cvelistv5 – Published: 2024-04-02 11:07 – Updated: 2024-11-06 21:00
    VLAI
    Summary
    There is an out-of-bounds read vulnerability in some Hikvision NVRs. An authenticated attacker could exploit this vulnerability by sending specially crafted messages to a vulnerable device, causing a service abnormality.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    Impacted products
    Vendor Product Version
    Hikvision DS-7604NXI-K1/4P Affected: V4.76.005 build231012 and the versions prior to it
    Create a notification for this product.
    Credits
    KITRI BoB 12th
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-29948",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-08-15T18:51:42.752876Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-125",
                    "description": "CWE-125 Out-of-bounds Read",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-11-06T21:00:14.957Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T01:17:58.501Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.hikvision.com/en/support/cybersecurity/security-advisory/security-vulnerabilities-in-hikvision-nvr-devices/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "affected",
              "product": "DS-7604NXI-K1/4P",
              "vendor": "Hikvision",
              "versions": [
                {
                  "status": "affected",
                  "version": "V4.76.005 build231012 and the versions prior to it"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "KITRI BoB 12th"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "There is an out-of-bounds read vulnerability in some Hikvision NVRs. An authenticated attacker could exploit this vulnerability by sending specially crafted messages to a vulnerable device, causing a service abnormality."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "LOW",
                "baseScore": 3.8,
                "baseSeverity": "LOW",
                "confidentialityImpact": "LOW",
                "integrityImpact": "NONE",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:N/A:L",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-04-02T11:07:04.983Z",
            "orgId": "da451dce-859b-4e51-8b87-9c8b60d19b32",
            "shortName": "hikvision"
          },
          "references": [
            {
              "url": "https://www.hikvision.com/en/support/cybersecurity/security-advisory/security-vulnerabilities-in-hikvision-nvr-devices/"
            }
          ],
          "x_generator": {
            "engine": "cveClient/1.0.15"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "da451dce-859b-4e51-8b87-9c8b60d19b32",
        "assignerShortName": "hikvision",
        "cveId": "CVE-2024-29948",
        "datePublished": "2024-04-02T11:07:04.983Z",
        "dateReserved": "2024-03-22T02:34:04.957Z",
        "dateUpdated": "2024-11-06T21:00:14.957Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }