    CVE-2025-57703 (GCVE-0-2025-57703)

    Vulnerability from nvd – Published: 2025-08-18 06:42 – Updated: 2025-08-19 00:17
    VLAI
    Title
    Reflected Cross-site Scripting in DIAEnergie
    Summary
    DIAEnergie - Reflected Cross-site Scripting
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
    Assigner
    Impacted products
    Vendor Product Version
    Delta Electronics DIAEnergie Affected: 0 , ≤ 1.11.00.002 (custom)
    Create a notification for this product.
    Date Public
    2025-08-18 06:25
    Credits
    Alex Williams of Converge Technology Solutions Cale Black of VulnCheck
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-57703",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-08-18T15:14:29.516226Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-08-18T15:19:56.689Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Windows"
              ],
              "product": "DIAEnergie",
              "vendor": "Delta Electronics",
              "versions": [
                {
                  "lessThanOrEqual": "1.11.00.002",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Alex Williams of Converge Technology Solutions"
            },
            {
              "lang": "en",
              "type": "coordinator",
              "value": "Cale Black of VulnCheck"
            }
          ],
          "datePublic": "2025-08-18T06:25:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDIAEnergie\u003c/span\u003e\u0026nbsp;- Reflected Cross-site Scripting"
                }
              ],
              "value": "DIAEnergie\u00a0- Reflected Cross-site Scripting"
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-591",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-591 Reflected XSS"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "HIGH",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 5.9,
                "baseSeverity": "MEDIUM",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "PASSIVE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:H/AT:N/PR:L/UI:P/VC:H/VI:L/VA:N/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "LOW",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-79",
                  "description": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-08-19T00:17:52.143Z",
            "orgId": "759f5e80-c8e1-4224-bead-956d7b33c98b",
            "shortName": "Deltaww"
          },
          "references": [
            {
              "url": "https://filecenter.deltaww.com/news/download/doc/Delta-PCSA-2025-00012_DIAEnergie%20Cross-Site%20Scripting%20Vulnerabilities.pdf"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Users are recommended to update DIAEnergie to v1.11.01.001 or later.\n\n\u003cbr\u003e"
                }
              ],
              "value": "Users are recommended to update DIAEnergie to v1.11.01.001 or later."
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "Reflected Cross-site Scripting in DIAEnergie",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "759f5e80-c8e1-4224-bead-956d7b33c98b",
        "assignerShortName": "Deltaww",
        "cveId": "CVE-2025-57703",
        "datePublished": "2025-08-18T06:42:48.812Z",
        "dateReserved": "2025-08-18T05:55:23.398Z",
        "dateUpdated": "2025-08-19T00:17:52.143Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-57702 (GCVE-0-2025-57702)

    Vulnerability from nvd – Published: 2025-08-18 06:42 – Updated: 2025-08-19 00:17
    VLAI
    Title
    Reflected Cross-site Scripting in DIAEnergie
    Summary
    DIAEnergie - Reflected Cross-site Scripting
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
    Assigner
    Impacted products
    Vendor Product Version
    Delta Electronics DIAEnergie Affected: 0 , ≤ 1.11.00.002 (custom)
    Create a notification for this product.
    Date Public
    2025-08-18 06:25
    Credits
    Alex Williams of Converge Technology Solutions Cale Black of VulnCheck
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-57702",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-08-18T15:20:41.744161Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-08-18T15:20:53.508Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Windows"
              ],
              "product": "DIAEnergie",
              "vendor": "Delta Electronics",
              "versions": [
                {
                  "lessThanOrEqual": "1.11.00.002",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Alex Williams of Converge Technology Solutions"
            },
            {
              "lang": "en",
              "type": "coordinator",
              "value": "Cale Black of VulnCheck"
            }
          ],
          "datePublic": "2025-08-18T06:25:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDIAEnergie\u003c/span\u003e\u0026nbsp;- Reflected Cross-site Scripting"
                }
              ],
              "value": "DIAEnergie\u00a0- Reflected Cross-site Scripting"
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-591",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-591 Reflected XSS"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "HIGH",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 5.9,
                "baseSeverity": "MEDIUM",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "PASSIVE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:H/AT:N/PR:L/UI:P/VC:H/VI:L/VA:N/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "LOW",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-79",
                  "description": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-08-19T00:17:38.206Z",
            "orgId": "759f5e80-c8e1-4224-bead-956d7b33c98b",
            "shortName": "Deltaww"
          },
          "references": [
            {
              "url": "https://filecenter.deltaww.com/news/download/doc/Delta-PCSA-2025-00012_DIAEnergie%20Cross-Site%20Scripting%20Vulnerabilities.pdf"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Users are recommended to update DIAEnergie to v1.11.01.001 or later.\n\n\u003cbr\u003e"
                }
              ],
              "value": "Users are recommended to update DIAEnergie to v1.11.01.001 or later."
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "Reflected Cross-site Scripting in DIAEnergie",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "759f5e80-c8e1-4224-bead-956d7b33c98b",
        "assignerShortName": "Deltaww",
        "cveId": "CVE-2025-57702",
        "datePublished": "2025-08-18T06:42:24.921Z",
        "dateReserved": "2025-08-18T05:55:23.398Z",
        "dateUpdated": "2025-08-19T00:17:38.206Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-57701 (GCVE-0-2025-57701)

    Vulnerability from nvd – Published: 2025-08-18 06:41 – Updated: 2025-08-19 00:17
    VLAI
    Title
    Reflected Cross-site Scripting in DIAEnergie
    Summary
    DIAEnergie - Reflected Cross-site Scripting
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
    Assigner
    Impacted products
    Vendor Product Version
    Delta Electronics DIAEnergie Affected: 0 , ≤ 1.11.00.002 (custom)
    Create a notification for this product.
    Date Public
    2025-08-18 06:25
    Credits
    Alex Williams of Converge Technology Solutions Cale Black of VulnCheck
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-57701",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-08-18T15:21:30.427149Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-08-18T15:21:39.485Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Windows"
              ],
              "product": "DIAEnergie",
              "vendor": "Delta Electronics",
              "versions": [
                {
                  "lessThanOrEqual": "1.11.00.002",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Alex Williams of Converge Technology Solutions"
            },
            {
              "lang": "en",
              "type": "coordinator",
              "value": "Cale Black of VulnCheck"
            }
          ],
          "datePublic": "2025-08-18T06:25:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDIAEnergie\u003c/span\u003e\u0026nbsp;- Reflected Cross-site Scripting"
                }
              ],
              "value": "DIAEnergie\u00a0- Reflected Cross-site Scripting"
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-591",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-591 Reflected XSS"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "HIGH",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 5.9,
                "baseSeverity": "MEDIUM",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "PASSIVE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:H/AT:N/PR:L/UI:P/VC:H/VI:L/VA:N/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "LOW",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-79",
                  "description": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-08-19T00:17:16.498Z",
            "orgId": "759f5e80-c8e1-4224-bead-956d7b33c98b",
            "shortName": "Deltaww"
          },
          "references": [
            {
              "url": "https://filecenter.deltaww.com/news/download/doc/Delta-PCSA-2025-00012_DIAEnergie%20Cross-Site%20Scripting%20Vulnerabilities.pdf"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Users are recommended to update DIAEnergie to v1.11.01.001 or later.\n\n\u003cbr\u003e"
                }
              ],
              "value": "Users are recommended to update DIAEnergie to v1.11.01.001 or later."
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "Reflected Cross-site Scripting in DIAEnergie",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "759f5e80-c8e1-4224-bead-956d7b33c98b",
        "assignerShortName": "Deltaww",
        "cveId": "CVE-2025-57701",
        "datePublished": "2025-08-18T06:41:55.539Z",
        "dateReserved": "2025-08-18T05:55:23.398Z",
        "dateUpdated": "2025-08-19T00:17:16.498Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-57700 (GCVE-0-2025-57700)

    Vulnerability from nvd – Published: 2025-08-18 06:28 – Updated: 2025-08-19 00:16
    VLAI
    Title
    Stored Cross-site Scripting in DIAEnergie
    Summary
    DIAEnergie - Stored Cross-site Scripting
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
    Assigner
    Impacted products
    Vendor Product Version
    Delta Electronics DIAEnergie Affected: 0 , ≤ 1.11.00.002 (custom)
    Create a notification for this product.
    Date Public
    2025-08-18 06:25
    Credits
    Alex Williams of Converge Technology Solutions Cale Black of VulnCheck
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-57700",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-08-18T15:26:23.762882Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-08-18T15:27:33.322Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Windows"
              ],
              "product": "DIAEnergie",
              "vendor": "Delta Electronics",
              "versions": [
                {
                  "lessThanOrEqual": "1.11.00.002",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Alex Williams of Converge Technology Solutions"
            },
            {
              "lang": "en",
              "type": "coordinator",
              "value": "Cale Black of VulnCheck"
            }
          ],
          "datePublic": "2025-08-18T06:25:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDIAEnergie\u003c/span\u003e\u0026nbsp;- Stored Cross-site Scripting"
                }
              ],
              "value": "DIAEnergie\u00a0- Stored Cross-site Scripting"
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-592",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-592 Stored XSS"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 7,
                "baseSeverity": "HIGH",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "PASSIVE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:P/VC:H/VI:L/VA:N/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "LOW",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-79",
                  "description": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-08-19T00:16:18.111Z",
            "orgId": "759f5e80-c8e1-4224-bead-956d7b33c98b",
            "shortName": "Deltaww"
          },
          "references": [
            {
              "url": "https://filecenter.deltaww.com/news/download/doc/Delta-PCSA-2025-00012_DIAEnergie%20Cross-Site%20Scripting%20Vulnerabilities.pdf"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Users are recommended to update DIAEnergie to v1.11.01.001 or later.\n\n\u003cbr\u003e"
                }
              ],
              "value": "Users are recommended to update DIAEnergie to v1.11.01.001 or later."
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "Stored Cross-site Scripting in DIAEnergie",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "759f5e80-c8e1-4224-bead-956d7b33c98b",
        "assignerShortName": "Deltaww",
        "cveId": "CVE-2025-57700",
        "datePublished": "2025-08-18T06:28:55.514Z",
        "dateReserved": "2025-08-18T05:55:23.397Z",
        "dateUpdated": "2025-08-19T00:16:18.111Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-43699 (GCVE-0-2024-43699)

    Vulnerability from nvd – Published: 2024-10-03 22:28 – Updated: 2024-10-04 14:15
    VLAI
    Title
    Delta Electronics DIAEnergie SQL Injection
    Summary
    Delta Electronics DIAEnergie is vulnerable to an SQL injection in the script AM_RegReport.aspx. An unauthenticated attacker may be able to exploit this issue to obtain records contained in the targeted product.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    Impacted products
    Vendor Product Version
    Delta Electronics DIAEnergie Affected: 0 , ≤ v1.10.01.008 (custom)
    Create a notification for this product.
    deltaww diaenergie Affected: 0 , ≤ 1.10.01.008 (custom)
        cpe:2.3:a:deltaww:diaenergie:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Credits
    Michael Heinzl reported these vulnerabilities to CISA.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:deltaww:diaenergie:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "diaenergie",
                "vendor": "deltaww",
                "versions": [
                  {
                    "lessThanOrEqual": "1.10.01.008",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-43699",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-10-04T14:14:50.609579Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-10-04T14:15:27.750Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "DIAEnergie",
              "vendor": "Delta Electronics",
              "versions": [
                {
                  "lessThanOrEqual": "v1.10.01.008",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Michael Heinzl reported these vulnerabilities to CISA."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta Electronics DIAEnergie is vulnerable to an SQL injection in the script AM_RegReport.aspx. An unauthenticated attacker may be able to exploit this issue to obtain records contained in the targeted product.\u003c/span\u003e"
                }
              ],
              "value": "Delta Electronics DIAEnergie is vulnerable to an SQL injection in the script AM_RegReport.aspx. An unauthenticated attacker may be able to exploit this issue to obtain records contained in the targeted product."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 9.3,
                "baseSeverity": "CRITICAL",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-89",
                  "description": "CWE-89 SQL Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-10-03T22:28:35.364Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-277-03"
            },
            {
              "url": "https://www.deltaww.com/en-US/Cybersecurity_Advisory"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eDelta recommends users update to DIAEnergie v1.10.01.009. Users can request this version of DIAEnergie from \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.deltaww.com/en-US/customerService\"\u003eDelta Electronics\u0027 regional sales or agents.\u003c/a\u003e\u003c/p\u003e\u003cp\u003eFor more information on this issue, please see the \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.deltaww.com/en-US/Cybersecurity_Advisory\"\u003eDelta product cybersecurity advisory.\u003c/a\u003e\u003c/p\u003e\n\n\u003cbr\u003e"
                }
              ],
              "value": "Delta recommends users update to DIAEnergie v1.10.01.009. Users can request this version of DIAEnergie from  Delta Electronics\u0027 regional sales or agents. https://www.deltaww.com/en-US/customerService \n\nFor more information on this issue, please see the  Delta product cybersecurity advisory. https://www.deltaww.com/en-US/Cybersecurity_Advisory"
            }
          ],
          "source": {
            "advisory": "ICSA-24-277-03",
            "discovery": "EXTERNAL"
          },
          "title": "Delta Electronics DIAEnergie SQL Injection",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2024-43699",
        "datePublished": "2024-10-03T22:28:35.364Z",
        "dateReserved": "2024-10-01T17:18:54.603Z",
        "dateUpdated": "2024-10-04T14:15:27.750Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-42417 (GCVE-0-2024-42417)

    Vulnerability from nvd – Published: 2024-10-03 22:32 – Updated: 2024-10-04 14:14
    VLAI
    Title
    Delta Electronics DIAEnergie SQL Injection
    Summary
    Delta Electronics DIAEnergie is vulnerable to an SQL injection in the script Handler_CFG.ashx. An authenticated attacker may be able to exploit this issue to cause delay in the targeted product.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    Impacted products
    Vendor Product Version
    Delta Electronics DIAEnergie Affected: 0 , ≤ v1.10.01.008 (custom)
    Create a notification for this product.
    deltaww diaenergie Affected: 0 , ≤ 1.10.01.008 (custom)
        cpe:2.3:a:deltaww:diaenergie:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Credits
    Michael Heinzl reported these vulnerabilities to CISA.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:deltaww:diaenergie:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "diaenergie",
                "vendor": "deltaww",
                "versions": [
                  {
                    "lessThanOrEqual": "1.10.01.008",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-42417",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-10-04T14:12:45.958174Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-10-04T14:14:32.287Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "DIAEnergie",
              "vendor": "Delta Electronics",
              "versions": [
                {
                  "lessThanOrEqual": "v1.10.01.008",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Michael Heinzl reported these vulnerabilities to CISA."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta Electronics DIAEnergie is vulnerable to an SQL injection in the script Handler_CFG.ashx. An authenticated attacker may be able to exploit this issue to cause delay in the targeted product.\u003c/span\u003e\n\n\u003c/span\u003e"
                }
              ],
              "value": "Delta Electronics DIAEnergie is vulnerable to an SQL injection in the script Handler_CFG.ashx. An authenticated attacker may be able to exploit this issue to cause delay in the targeted product."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-89",
                  "description": "CWE-89 SQL Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-10-03T22:32:59.999Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-277-03"
            },
            {
              "url": "https://www.deltaww.com/en-US/Cybersecurity_Advisory"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eDelta recommends users update to DIAEnergie v1.10.01.009. Users can request this version of DIAEnergie from \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.deltaww.com/en-US/customerService\"\u003eDelta Electronics\u0027 regional sales or agents.\u003c/a\u003e\u003c/p\u003e\u003cp\u003eFor more information on this issue, please see the \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.deltaww.com/en-US/Cybersecurity_Advisory\"\u003eDelta product cybersecurity advisory.\u003c/a\u003e\u003c/p\u003e\n\n\u003cbr\u003e"
                }
              ],
              "value": "Delta recommends users update to DIAEnergie v1.10.01.009. Users can request this version of DIAEnergie from  Delta Electronics\u0027 regional sales or agents. https://www.deltaww.com/en-US/customerService \n\nFor more information on this issue, please see the  Delta product cybersecurity advisory. https://www.deltaww.com/en-US/Cybersecurity_Advisory"
            }
          ],
          "source": {
            "advisory": "ICSA-24-277-03",
            "discovery": "EXTERNAL"
          },
          "title": "Delta Electronics DIAEnergie SQL Injection",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2024-42417",
        "datePublished": "2024-10-03T22:32:59.999Z",
        "dateReserved": "2024-10-01T17:18:54.590Z",
        "dateUpdated": "2024-10-04T14:14:32.287Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-4549 (GCVE-0-2024-4549)

    Vulnerability from nvd – Published: 2024-05-06 13:54 – Updated: 2024-08-01 20:47
    VLAI
    Title
    Delta Electronics DIAEnergie SQL Injection
    Summary
    A denial of service vulnerability exists in Delta Electronics DIAEnergie v1.10.1.8610 and prior. When processing an 'ICS Restart!' message, CEBC.exe restarts the system.
    SSVC
    Exploitation: poc Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-400 - Uncontrolled Resource Consumption
    Assigner
    Impacted products
    Vendor Product Version
    Delta Electronics DIAEnergie Affected: 0 , ≤ 1.10.1.8610 (custom)
    Create a notification for this product.
    deltaww diaenergie Affected: 0 , ≤ 1.10.1.8610 (custom)
        cpe:2.3:a:deltaww:diaenergie:-:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:deltaww:diaenergie:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "diaenergie",
                "vendor": "deltaww",
                "versions": [
                  {
                    "lessThanOrEqual": "1.10.1.8610",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-4549",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-05-06T15:35:29.745502Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-400",
                    "description": "CWE-400 Uncontrolled Resource Consumption",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-06-20T20:08:39.537Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-01T20:47:41.185Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.tenable.com/security/research/tra-2024-13"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "DIAEnergie",
              "vendor": "Delta Electronics",
              "versions": [
                {
                  "lessThanOrEqual": "1.10.1.8610",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "A denial of service vulnerability exists in Delta Electronics DIAEnergie v1.10.1.8610 and prior. When processing an \u0027ICS Restart!\u0027 message, CEBC.exe restarts the system."
                }
              ],
              "value": "A denial of service vulnerability exists in Delta Electronics DIAEnergie v1.10.1.8610 and prior. When processing an \u0027ICS Restart!\u0027 message, CEBC.exe restarts the system."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-05-06T20:47:40.285Z",
            "orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
            "shortName": "tenable"
          },
          "references": [
            {
              "url": "https://www.tenable.com/security/research/tra-2024-13"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Delta Electronics DIAEnergie SQL Injection ",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
        "assignerShortName": "tenable",
        "cveId": "CVE-2024-4549",
        "datePublished": "2024-05-06T13:54:32.808Z",
        "dateReserved": "2024-05-06T13:35:44.109Z",
        "dateUpdated": "2024-08-01T20:47:41.185Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-4548 (GCVE-0-2024-4548)

    Vulnerability from nvd – Published: 2024-05-06 13:51 – Updated: 2024-08-01 20:47
    VLAI
    Title
    Delta Electronics DIAEnergie SQL Injection
    Summary
    An SQLi vulnerability exists in Delta Electronics DIAEnergie v1.10.1.8610 and prior when CEBC.exe processes a 'RecalculateHDMWYC' message, which is split into 4 fields using the '~' character as the separator. An unauthenticated remote attacker can perform SQLi via the fourth field.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-20 - Improper Input Validation
    Assigner
    Impacted products
    Vendor Product Version
    Delta Electronics DIAEnergie Affected: 0 , ≤ 1.10.1.8610 (custom)
    Create a notification for this product.
    deltaww diaenergie Affected: 0 , ≤ 1.10.1.8610 (custom)
        cpe:2.3:a:deltaww:diaenergie:-:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:deltaww:diaenergie:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "diaenergie",
                "vendor": "deltaww",
                "versions": [
                  {
                    "lessThanOrEqual": "1.10.1.8610",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-4548",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-05-13T13:41:00.312856Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-06-20T20:06:39.622Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-01T20:47:40.056Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.tenable.com/security/research/tra-2024-13"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "DIAEnergie",
              "vendor": "Delta Electronics",
              "versions": [
                {
                  "lessThanOrEqual": "1.10.1.8610",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "An SQLi vulnerability exists in\u0026nbsp;Delta Electronics DIAEnergie v1.10.1.8610 and prior when CEBC.exe processes a \u0027RecalculateHDMWYC\u0027 message, which is split into 4 fields using the \u0027~\u0027 character as the separator. An unauthenticated remote attacker can perform SQLi via the fourth field."
                }
              ],
              "value": "An SQLi vulnerability exists in\u00a0Delta Electronics DIAEnergie v1.10.1.8610 and prior when CEBC.exe processes a \u0027RecalculateHDMWYC\u0027 message, which is split into 4 fields using the \u0027~\u0027 character as the separator. An unauthenticated remote attacker can perform SQLi via the fourth field."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-66",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-66 SQL Injection"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-20",
                  "description": "CWE-20 Improper Input Validation",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-05-06T13:51:07.049Z",
            "orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
            "shortName": "tenable"
          },
          "references": [
            {
              "url": "https://www.tenable.com/security/research/tra-2024-13"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Delta Electronics DIAEnergie SQL Injection",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
        "assignerShortName": "tenable",
        "cveId": "CVE-2024-4548",
        "datePublished": "2024-05-06T13:51:07.049Z",
        "dateReserved": "2024-05-06T13:35:43.319Z",
        "dateUpdated": "2024-08-01T20:47:40.056Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-4547 (GCVE-0-2024-4547)

    Vulnerability from nvd – Published: 2024-05-06 13:48 – Updated: 2024-08-01 20:47
    VLAI
    Title
    Delta Electronics DIAEnergie Unauthenticated SQL Injection
    Summary
    A SQLi vulnerability exists in Delta Electronics DIAEnergie v1.10.1.8610 and prior when CEBC.exe processes a 'RecalculateScript' message, which is splitted into 4 fields using the '~' character as the separator. An unauthenticated remote attacker can perform SQLi via the fourth field
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-20 - Improper Input Validation
    Assigner
    Impacted products
    Vendor Product Version
    Delta Electronics DIAEnergie Affected: 0 , ≤ 1.10.1.8610 (custom)
    Create a notification for this product.
    deltaww diaenergie Affected: - , ≤ 1.10.1.8610 (custom)
        cpe:2.3:a:deltaww:diaenergie:-:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:deltaww:diaenergie:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "diaenergie",
                "vendor": "deltaww",
                "versions": [
                  {
                    "lessThanOrEqual": "1.10.1.8610",
                    "status": "affected",
                    "version": "-",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-4547",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-05-06T18:33:49.309166Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-06-20T20:08:45.951Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-01T20:47:40.554Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.tenable.com/security/research/tra-2024-13"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "DIAEnergie",
              "vendor": "Delta Electronics",
              "versions": [
                {
                  "lessThanOrEqual": "1.10.1.8610",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "A SQLi vulnerability exists in\u0026nbsp;Delta Electronics\u0026nbsp;DIAEnergie v1.10.1.8610 and prior when CEBC.exe processes a \u0027RecalculateScript\u0027 message, which is splitted into 4 fields using the \u0027~\u0027 character as the separator. An unauthenticated remote attacker can perform SQLi via the fourth field"
                }
              ],
              "value": "A SQLi vulnerability exists in\u00a0Delta Electronics\u00a0DIAEnergie v1.10.1.8610 and prior when CEBC.exe processes a \u0027RecalculateScript\u0027 message, which is splitted into 4 fields using the \u0027~\u0027 character as the separator. An unauthenticated remote attacker can perform SQLi via the fourth field"
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-66",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-66 SQL Injection"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-20",
                  "description": "CWE-20 Improper Input Validation",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-05-06T13:48:08.737Z",
            "orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
            "shortName": "tenable"
          },
          "references": [
            {
              "url": "https://www.tenable.com/security/research/tra-2024-13"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Delta Electronics DIAEnergie Unauthenticated SQL Injection",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
        "assignerShortName": "tenable",
        "cveId": "CVE-2024-4547",
        "datePublished": "2024-05-06T13:48:08.737Z",
        "dateReserved": "2024-05-06T13:35:42.505Z",
        "dateUpdated": "2024-08-01T20:47:40.554Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-34033 (GCVE-0-2024-34033)

    Vulnerability from nvd – Published: 2024-05-03 00:20 – Updated: 2024-08-12 20:08
    VLAI
    Title
    Path Traversal vulnerability in Delta Electronics DIAEnergie
    Summary
    Delta Electronics DIAEnergie has insufficient input validation which makes it possible to perform a path traversal attack and write outside of the intended directory. If a file name is specified that already exists on the file system, then the original file will be overwritten.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
    Assigner
    References
    Impacted products
    Vendor Product Version
    Delta Electronics DIAEnergie Affected: 1.10.00.005
    Create a notification for this product.
    deltaww diaenergie Affected: 0 , < 1.10.01.004 (custom)
        cpe:2.3:a:deltaww:diaenergie:-:*:*:*:*:*:*:*
    Create a notification for this product.
    Credits
    Michael Heinzl reported these vulnerabilities to CISA.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:deltaww:diaenergie:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "diaenergie",
                "vendor": "deltaww",
                "versions": [
                  {
                    "lessThan": "1.10.01.004",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-34033",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-06-26T17:53:32.429375Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-08-12T20:08:16.443Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T02:42:59.870Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "government-resource",
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-123-02"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "DIAEnergie ",
              "vendor": "Delta Electronics",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.10.00.005"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Michael Heinzl reported these vulnerabilities to CISA."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta Electronics DIAEnergie has insufficient input validation which makes it possible to perform a path traversal attack and write outside of the intended directory. If a file name is specified that already exists on the file system, then the original file will be overwritten.\u003c/span\u003e\n\n\u003c/span\u003e\n\n\u003c/span\u003e\n\n"
                }
              ],
              "value": "\nDelta Electronics DIAEnergie has insufficient input validation which makes it possible to perform a path traversal attack and write outside of the intended directory. If a file name is specified that already exists on the file system, then the original file will be overwritten.\n\n"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-22",
                  "description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-05-03T00:20:03.319Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-123-02"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta Electronics recommends users update to DIAEnergie v1.10.01.004 to mitigate these vulnerabilities. Users can request this version of DIAEnergie from Delta Electronics\u0027 regional sales or agents.\u003c/span\u003e\n\n\u003cbr\u003e"
                }
              ],
              "value": "\nDelta Electronics recommends users update to DIAEnergie v1.10.01.004 to mitigate these vulnerabilities. Users can request this version of DIAEnergie from Delta Electronics\u0027 regional sales or agents.\n\n"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Path Traversal vulnerability in Delta Electronics DIAEnergie ",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2024-34033",
        "datePublished": "2024-05-03T00:20:03.319Z",
        "dateReserved": "2024-04-29T17:56:18.036Z",
        "dateUpdated": "2024-08-12T20:08:16.443Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-34032 (GCVE-0-2024-34032)

    Vulnerability from nvd – Published: 2024-05-03 00:16 – Updated: 2024-08-12 20:08
    VLAI
    Title
    SQL Injection in Delta Electronics DIAEnergie
    Summary
    Delta Electronics DIAEnergie is vulnerable to an SQL injection vulnerability that exists in the GetDIACloudList endpoint. An authenticated attacker can exploit this issue to potentially compromise the system on which DIAEnergie is deployed.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') CWE-89
    Assigner
    References
    Impacted products
    Vendor Product Version
    Delta Electronics DIAEnergie Affected: 1.10.00.005
    Create a notification for this product.
    deltaww diaenergie Affected: 0
        cpe:2.3:a:deltaww:diaenergie:-:*:*:*:*:*:*:*
    Create a notification for this product.
    Credits
    Michael Heinzl reported these vulnerabilities to CISA.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:deltaww:diaenergie:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "diaenergie",
                "vendor": "deltaww",
                "versions": [
                  {
                    "status": "affected",
                    "version": "0"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-34032",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-06-25T19:09:34.838148Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-08-12T20:08:42.943Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T02:42:59.827Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "government-resource",
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-123-02"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "DIAEnergie ",
              "vendor": "Delta Electronics",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.10.00.005"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Michael Heinzl reported these vulnerabilities to CISA."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta Electronics DIAEnergie is vulnerable to an SQL injection vulnerability that exists in the GetDIACloudList endpoint. An authenticated attacker can exploit this issue to potentially compromise the system on which DIAEnergie is deployed.\u003c/span\u003e\n\n\u003c/span\u003e\n\n"
                }
              ],
              "value": "\nDelta Electronics DIAEnergie is vulnerable to an SQL injection vulnerability that exists in the GetDIACloudList endpoint. An authenticated attacker can exploit this issue to potentially compromise the system on which DIAEnergie is deployed.\n\n"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-89",
                  "description": " Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027) CWE-89",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-05-03T00:16:40.017Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-123-02"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta Electronics recommends users update to DIAEnergie v1.10.01.004 to mitigate these vulnerabilities. Users can request this version of DIAEnergie from Delta Electronics\u0027 regional sales or agents.\u003c/span\u003e\n\n\u003cbr\u003e"
                }
              ],
              "value": "\nDelta Electronics recommends users update to DIAEnergie v1.10.01.004 to mitigate these vulnerabilities. Users can request this version of DIAEnergie from Delta Electronics\u0027 regional sales or agents.\n\n"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "SQL Injection in Delta Electronics DIAEnergie ",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2024-34032",
        "datePublished": "2024-05-03T00:16:40.017Z",
        "dateReserved": "2024-04-29T17:56:18.036Z",
        "dateUpdated": "2024-08-12T20:08:42.943Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-34031 (GCVE-0-2024-34031)

    Vulnerability from nvd – Published: 2024-05-03 00:18 – Updated: 2024-08-12 20:09
    VLAI
    Title
    SQL Injection vulnerability in Delta Electronics DIAEnergie
    Summary
    Delta Electronics DIAEnergie is vulnerable to an SQL injection vulnerability that exists in the script Handler_CFG.ashx. An authenticated attacker can exploit this issue to potentially compromise the system on which DIAEnergie is deployed.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') CWE-89
    Assigner
    References
    Impacted products
    Vendor Product Version
    Delta Electronics DIAEnergie Affected: 1.10.00.005
    Create a notification for this product.
    deltaww diaenergie Affected: 1.10.00.005
        cpe:2.3:a:deltaww:diaenergie:1.10.00.005:*:*:*:*:*:*:*
    Create a notification for this product.
    Credits
    Michael Heinzl reported these vulnerabilities to CISA.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:deltaww:diaenergie:1.10.00.005:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "diaenergie",
                "vendor": "deltaww",
                "versions": [
                  {
                    "status": "affected",
                    "version": "1.10.00.005"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-34031",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-06-25T19:07:57.188972Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-08-12T20:09:18.872Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T02:42:59.938Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "government-resource",
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-123-02"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "DIAEnergie ",
              "vendor": "Delta Electronics",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.10.00.005"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Michael Heinzl reported these vulnerabilities to CISA."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta Electronics DIAEnergie is vulnerable to an SQL injection vulnerability that exists in the script Handler_CFG.ashx. An authenticated attacker can exploit this issue to potentially compromise the system on which DIAEnergie is deployed.\u003c/span\u003e\n\n"
                }
              ],
              "value": "\nDelta Electronics DIAEnergie is vulnerable to an SQL injection vulnerability that exists in the script Handler_CFG.ashx. An authenticated attacker can exploit this issue to potentially compromise the system on which DIAEnergie is deployed.\n\n"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-89",
                  "description": " Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027) CWE-89",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-05-03T00:18:13.497Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-123-02"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta Electronics recommends users update to DIAEnergie v1.10.01.004 to mitigate these vulnerabilities. Users can request this version of DIAEnergie from Delta Electronics\u0027 regional sales or agents.\u003c/span\u003e\n\n\u003cbr\u003e"
                }
              ],
              "value": "\nDelta Electronics recommends users update to DIAEnergie v1.10.01.004 to mitigate these vulnerabilities. Users can request this version of DIAEnergie from Delta Electronics\u0027 regional sales or agents.\n\n"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": " SQL Injection vulnerability in Delta Electronics DIAEnergie ",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2024-34031",
        "datePublished": "2024-05-03T00:18:13.497Z",
        "dateReserved": "2024-04-29T17:56:18.035Z",
        "dateUpdated": "2024-08-12T20:09:18.872Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-25574 (GCVE-0-2024-25574)

    Vulnerability from nvd – Published: 2024-04-01 16:04 – Updated: 2024-08-01 23:44
    VLAI
    Title
    Delta Electronics DIAEnergie SQL Injection
    Summary
    SQL injection vulnerability exists in GetDIAE_usListParameters.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    Impacted products
    Vendor Product Version
    Delta Electronics DIAEnergie Affected: 0 , < v1.10.00.005 (custom)
    Create a notification for this product.
    deltaww diaenergie Affected: 0 , < 1.10.00.005 (custom)
        cpe:2.3:a:deltaww:diaenergie:-:*:*:*:*:*:*:*
    Create a notification for this product.
    Date Public
    2024-03-14 17:00
    Credits
    Michael Heinzl reported these vulnerabilities to CISA.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:deltaww:diaenergie:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "diaenergie",
                "vendor": "deltaww",
                "versions": [
                  {
                    "lessThan": "1.10.00.005",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-25574",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-04-01T17:13:46.607653Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-06-20T20:09:02.248Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-01T23:44:09.659Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-074-12"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "DIAEnergie",
              "vendor": "Delta Electronics",
              "versions": [
                {
                  "lessThan": "v1.10.00.005",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Michael Heinzl reported these vulnerabilities to CISA."
            }
          ],
          "datePublic": "2024-03-14T17:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\nSQL injection vulnerability exists in GetDIAE_usListParameters.\n\n\u003c/span\u003e\n\n"
                }
              ],
              "value": "\nSQL injection vulnerability exists in GetDIAE_usListParameters.\n\n"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-89",
                  "description": "CWE-89 SQL Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-04-01T16:04:46.800Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-074-12"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta recommends users update to DIAEnergie v1.10.00.005. Users can request this version of DIAEnergie from \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.deltaww.com/en/customerService\"\u003eDelta Electronics\u0027 regional sales or agents\u003c/a\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e.\u003c/span\u003e\n\n\u003cbr\u003e"
                }
              ],
              "value": "\nDelta recommends users update to DIAEnergie v1.10.00.005. Users can request this version of DIAEnergie from  Delta Electronics\u0027 regional sales or agents https://www.deltaww.com/en/customerService .\n\n"
            }
          ],
          "source": {
            "advisory": "ICSA-24-074-12",
            "discovery": "EXTERNAL"
          },
          "title": "Delta Electronics DIAEnergie SQL Injection",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2024-25574",
        "datePublished": "2024-04-01T16:04:46.800Z",
        "dateReserved": "2024-03-12T15:07:02.593Z",
        "dateUpdated": "2024-08-01T23:44:09.659Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-28171 (GCVE-0-2024-28171)

    Vulnerability from nvd – Published: 2024-03-21 22:19 – Updated: 2024-08-28 14:18
    VLAI
    Title
    Delta Electronics DIAEnergie Path traversal
    Summary
    It is possible to perform a path traversal attack and write outside of the intended directory. If a file name is specified that already exists on the file system, then the original file will be overwritten.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-22 - Improper limitation of a pathname to a restricted directory ('Path traversal')
    Assigner
    Impacted products
    Vendor Product Version
    Delta Electronics DIAEnergie Affected: 0 , < v1.10.00.005 (custom)
    Create a notification for this product.
    delta_electronics diaenergie Affected: 0 , < v1.10.00.005 (custom)
        cpe:2.3:a:delta_electronics:diaenergie:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Date Public
    2024-03-14 17:00
    Credits
    Michael Heinzl reported these vulnerabilities to CISA.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T00:48:49.142Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-074-12"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:delta_electronics:diaenergie:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "diaenergie",
                "vendor": "delta_electronics",
                "versions": [
                  {
                    "lessThan": "v1.10.00.005",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-28171",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-03-22T17:56:00.396002Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-08-28T14:18:49.656Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "DIAEnergie",
              "vendor": "Delta Electronics",
              "versions": [
                {
                  "lessThan": "v1.10.00.005",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Michael Heinzl reported these vulnerabilities to CISA."
            }
          ],
          "datePublic": "2024-03-14T17:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eIt is possible to perform a path traversal attack and write outside of the intended directory. If a file name is specified that already exists on the file system, then the original file will be overwritten.\u003c/span\u003e\n\n"
                }
              ],
              "value": "\nIt is possible to perform a path traversal attack and write outside of the intended directory. If a file name is specified that already exists on the file system, then the original file will be overwritten.\n\n"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.1,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-22",
                  "description": "CWE-22: Improper limitation of a pathname to a restricted directory (\u0027Path traversal\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-03-21T22:19:36.480Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-074-12"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta recommends users update to DIAEnergie v1.10.00.005. Users can request this version of DIAEnergie from \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.deltaww.com/en/customerService\"\u003eDelta Electronics\u0027 regional sales or agents\u003c/a\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e.\u003c/span\u003e\n\n\u003cbr\u003e"
                }
              ],
              "value": "\nDelta recommends users update to DIAEnergie v1.10.00.005. Users can request this version of DIAEnergie from  Delta Electronics\u0027 regional sales or agents https://www.deltaww.com/en/customerService .\n\n"
            }
          ],
          "source": {
            "advisory": "ICSA-24-074-12",
            "discovery": "EXTERNAL"
          },
          "title": "Delta Electronics DIAEnergie Path traversal",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2024-28171",
        "datePublished": "2024-03-21T22:19:36.480Z",
        "dateReserved": "2024-03-12T15:07:02.588Z",
        "dateUpdated": "2024-08-28T14:18:49.656Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-28045 (GCVE-0-2024-28045)

    Vulnerability from nvd – Published: 2024-03-21 22:24 – Updated: 2024-08-02 00:48
    VLAI
    Title
    Delta Electronics DIAEnergie Cross-site scripting
    Summary
    Improper neutralization of input within the affected product could lead to cross-site scripting.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-79 - Improper neutralization of input during web page generation ('Cross-site scripting')
    Assigner
    Impacted products
    Vendor Product Version
    Delta Electronics DIAEnergie Affected: 0 , < v1.10.00.005 (custom)
    Create a notification for this product.
    Date Public
    2024-03-14 17:00
    Credits
    Michael Heinzl reported these vulnerabilities to CISA.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-28045",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-03-27T14:14:37.320637Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-06-04T18:04:05.637Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T00:48:47.822Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-074-12"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "DIAEnergie",
              "vendor": "Delta Electronics",
              "versions": [
                {
                  "lessThan": "v1.10.00.005",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Michael Heinzl reported these vulnerabilities to CISA."
            }
          ],
          "datePublic": "2024-03-14T17:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eImproper neutralization of input within the affected product could lead to cross-site scripting.\u003c/span\u003e\n\n"
                }
              ],
              "value": "\nImproper neutralization of input within the affected product could lead to cross-site scripting.\n\n"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 4.6,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:L/I:L/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-79",
                  "description": "CWE-79: Improper neutralization of input during web page generation (\u0027Cross-site scripting\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-03-21T22:24:12.286Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-074-12"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta recommends users update to DIAEnergie v1.10.00.005. Users can request this version of DIAEnergie from \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.deltaww.com/en/customerService\"\u003eDelta Electronics\u0027 regional sales or agents\u003c/a\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e.\u003c/span\u003e\n\n\u003cbr\u003e"
                }
              ],
              "value": "\nDelta recommends users update to DIAEnergie v1.10.00.005. Users can request this version of DIAEnergie from  Delta Electronics\u0027 regional sales or agents https://www.deltaww.com/en/customerService .\n\n"
            }
          ],
          "source": {
            "advisory": "ICSA-24-074-12",
            "discovery": "EXTERNAL"
          },
          "title": "Delta Electronics DIAEnergie Cross-site scripting",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2024-28045",
        "datePublished": "2024-03-21T22:24:12.286Z",
        "dateReserved": "2024-03-12T15:07:02.565Z",
        "dateUpdated": "2024-08-02T00:48:47.822Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-28040 (GCVE-0-2024-28040)

    Vulnerability from nvd – Published: 2024-03-21 22:13 – Updated: 2024-08-12 20:14
    VLAI
    Title
    Delta Electronics DIAEnergie SQL injection
    Summary
    SQL injection vulnerability exists in GetDIAE_astListParameters.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-89 - Improper neutralization of special elements used in an SQL command ('SQL injection')
    Assigner
    Impacted products
    Vendor Product Version
    Delta Electronics DIAEnergie Affected: 0 , < v1.10.00.005 (custom)
    Create a notification for this product.
    deltaww diaenergie Affected: 0 , < 1.10.00.005 (custom)
        cpe:2.3:a:deltaww:diaenergie:-:*:*:*:*:*:*:*
    Create a notification for this product.
    Date Public
    2024-03-14 17:00
    Credits
    Michael Heinzl reported these vulnerabilities to CISA.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T00:48:47.823Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-074-12"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:deltaww:diaenergie:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "diaenergie",
                "vendor": "deltaww",
                "versions": [
                  {
                    "lessThan": "1.10.00.005",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-28040",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-03-28T19:11:12.203178Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-08-12T20:14:25.821Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "DIAEnergie",
              "vendor": "Delta Electronics",
              "versions": [
                {
                  "lessThan": "v1.10.00.005",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Michael Heinzl reported these vulnerabilities to CISA."
            }
          ],
          "datePublic": "2024-03-14T17:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eSQL injection vulnerability exists in GetDIAE_astListParameters.\u003c/span\u003e\n\n"
                }
              ],
              "value": "\nSQL injection vulnerability exists in GetDIAE_astListParameters.\n\n"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-89",
                  "description": "CWE-89 Improper neutralization of special elements used in an SQL command (\u0027SQL injection\u0027) ",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-03-21T22:13:40.119Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-074-12"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta recommends users update to DIAEnergie v1.10.00.005. Users can request this version of DIAEnergie from \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.deltaww.com/en/customerService\"\u003eDelta Electronics\u0027 regional sales or agents\u003c/a\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e.\u003c/span\u003e\n\n\u003cbr\u003e"
                }
              ],
              "value": "\nDelta recommends users update to DIAEnergie v1.10.00.005. Users can request this version of DIAEnergie from  Delta Electronics\u0027 regional sales or agents https://www.deltaww.com/en/customerService .\n\n"
            }
          ],
          "source": {
            "advisory": "ICSA-24-074-12",
            "discovery": "EXTERNAL"
          },
          "title": "Delta Electronics DIAEnergie SQL injection",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2024-28040",
        "datePublished": "2024-03-21T22:13:40.119Z",
        "dateReserved": "2024-03-12T15:07:02.634Z",
        "dateUpdated": "2024-08-12T20:14:25.821Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-25567 (GCVE-0-2024-25567)

    Vulnerability from nvd – Published: 2024-03-21 22:22 – Updated: 2024-08-01 23:44
    VLAI
    Title
    Delta Electronics DIAEnergie Path traversal
    Summary
    Path traversal attack is possible and write outside of the intended directory and may access sensitive information. If a file name is specified that already exists on the file system, then the original file will be overwritten.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-22 - Improper limitation of a pathname to a restricted directory ('Path traversal')
    Assigner
    Impacted products
    Vendor Product Version
    Delta Electronics DIAEnergie Affected: 0 , < v1.10.00.005 (custom)
    Create a notification for this product.
    Date Public
    2024-03-14 17:00
    Credits
    Michael Heinzl reported these vulnerabilities to CISA.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-25567",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-08-01T20:55:05.307378Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-08-01T20:55:20.449Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-01T23:44:09.621Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-074-12"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "DIAEnergie",
              "vendor": "Delta Electronics",
              "versions": [
                {
                  "lessThan": "v1.10.00.005",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Michael Heinzl reported these vulnerabilities to CISA."
            }
          ],
          "datePublic": "2024-03-14T17:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003ePath traversal attack is possible and write outside of the intended directory and may access sensitive information. If a file name is specified that already exists on the file system, then the original file will be overwritten.\u003c/span\u003e\n\n"
                }
              ],
              "value": "\nPath traversal attack is possible and write outside of the intended directory and may access sensitive information. If a file name is specified that already exists on the file system, then the original file will be overwritten.\n\n"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.1,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-22",
                  "description": "CWE-22: Improper limitation of a pathname to a restricted directory (\u0027Path traversal\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-03-21T22:22:17.780Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-074-12"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta recommends users update to DIAEnergie v1.10.00.005. Users can request this version of DIAEnergie from \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.deltaww.com/en/customerService\"\u003eDelta Electronics\u0027 regional sales or agents\u003c/a\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e.\u003c/span\u003e\n\n\u003cbr\u003e"
                }
              ],
              "value": "\nDelta recommends users update to DIAEnergie v1.10.00.005. Users can request this version of DIAEnergie from  Delta Electronics\u0027 regional sales or agents https://www.deltaww.com/en/customerService .\n\n"
            }
          ],
          "source": {
            "advisory": "ICSA-24-074-12",
            "discovery": "EXTERNAL"
          },
          "title": "Delta Electronics DIAEnergie Path traversal",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2024-25567",
        "datePublished": "2024-03-21T22:22:17.780Z",
        "dateReserved": "2024-03-12T15:07:02.581Z",
        "dateUpdated": "2024-08-01T23:44:09.621Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-57703 (GCVE-0-2025-57703)

    Vulnerability from cvelistv5 – Published: 2025-08-18 06:42 – Updated: 2025-08-19 00:17
    VLAI
    Title
    Reflected Cross-site Scripting in DIAEnergie
    Summary
    DIAEnergie - Reflected Cross-site Scripting
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
    Assigner
    Impacted products
    Vendor Product Version
    Delta Electronics DIAEnergie Affected: 0 , ≤ 1.11.00.002 (custom)
    Create a notification for this product.
    Date Public
    2025-08-18 06:25
    Credits
    Alex Williams of Converge Technology Solutions Cale Black of VulnCheck
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-57703",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-08-18T15:14:29.516226Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-08-18T15:19:56.689Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Windows"
              ],
              "product": "DIAEnergie",
              "vendor": "Delta Electronics",
              "versions": [
                {
                  "lessThanOrEqual": "1.11.00.002",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Alex Williams of Converge Technology Solutions"
            },
            {
              "lang": "en",
              "type": "coordinator",
              "value": "Cale Black of VulnCheck"
            }
          ],
          "datePublic": "2025-08-18T06:25:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDIAEnergie\u003c/span\u003e\u0026nbsp;- Reflected Cross-site Scripting"
                }
              ],
              "value": "DIAEnergie\u00a0- Reflected Cross-site Scripting"
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-591",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-591 Reflected XSS"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "HIGH",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 5.9,
                "baseSeverity": "MEDIUM",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "PASSIVE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:H/AT:N/PR:L/UI:P/VC:H/VI:L/VA:N/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "LOW",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-79",
                  "description": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-08-19T00:17:52.143Z",
            "orgId": "759f5e80-c8e1-4224-bead-956d7b33c98b",
            "shortName": "Deltaww"
          },
          "references": [
            {
              "url": "https://filecenter.deltaww.com/news/download/doc/Delta-PCSA-2025-00012_DIAEnergie%20Cross-Site%20Scripting%20Vulnerabilities.pdf"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Users are recommended to update DIAEnergie to v1.11.01.001 or later.\n\n\u003cbr\u003e"
                }
              ],
              "value": "Users are recommended to update DIAEnergie to v1.11.01.001 or later."
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "Reflected Cross-site Scripting in DIAEnergie",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "759f5e80-c8e1-4224-bead-956d7b33c98b",
        "assignerShortName": "Deltaww",
        "cveId": "CVE-2025-57703",
        "datePublished": "2025-08-18T06:42:48.812Z",
        "dateReserved": "2025-08-18T05:55:23.398Z",
        "dateUpdated": "2025-08-19T00:17:52.143Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-57702 (GCVE-0-2025-57702)

    Vulnerability from cvelistv5 – Published: 2025-08-18 06:42 – Updated: 2025-08-19 00:17
    VLAI
    Title
    Reflected Cross-site Scripting in DIAEnergie
    Summary
    DIAEnergie - Reflected Cross-site Scripting
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
    Assigner
    Impacted products
    Vendor Product Version
    Delta Electronics DIAEnergie Affected: 0 , ≤ 1.11.00.002 (custom)
    Create a notification for this product.
    Date Public
    2025-08-18 06:25
    Credits
    Alex Williams of Converge Technology Solutions Cale Black of VulnCheck
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-57702",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-08-18T15:20:41.744161Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-08-18T15:20:53.508Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Windows"
              ],
              "product": "DIAEnergie",
              "vendor": "Delta Electronics",
              "versions": [
                {
                  "lessThanOrEqual": "1.11.00.002",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Alex Williams of Converge Technology Solutions"
            },
            {
              "lang": "en",
              "type": "coordinator",
              "value": "Cale Black of VulnCheck"
            }
          ],
          "datePublic": "2025-08-18T06:25:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDIAEnergie\u003c/span\u003e\u0026nbsp;- Reflected Cross-site Scripting"
                }
              ],
              "value": "DIAEnergie\u00a0- Reflected Cross-site Scripting"
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-591",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-591 Reflected XSS"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "HIGH",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 5.9,
                "baseSeverity": "MEDIUM",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "PASSIVE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:H/AT:N/PR:L/UI:P/VC:H/VI:L/VA:N/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "LOW",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-79",
                  "description": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-08-19T00:17:38.206Z",
            "orgId": "759f5e80-c8e1-4224-bead-956d7b33c98b",
            "shortName": "Deltaww"
          },
          "references": [
            {
              "url": "https://filecenter.deltaww.com/news/download/doc/Delta-PCSA-2025-00012_DIAEnergie%20Cross-Site%20Scripting%20Vulnerabilities.pdf"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Users are recommended to update DIAEnergie to v1.11.01.001 or later.\n\n\u003cbr\u003e"
                }
              ],
              "value": "Users are recommended to update DIAEnergie to v1.11.01.001 or later."
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "Reflected Cross-site Scripting in DIAEnergie",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "759f5e80-c8e1-4224-bead-956d7b33c98b",
        "assignerShortName": "Deltaww",
        "cveId": "CVE-2025-57702",
        "datePublished": "2025-08-18T06:42:24.921Z",
        "dateReserved": "2025-08-18T05:55:23.398Z",
        "dateUpdated": "2025-08-19T00:17:38.206Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-57701 (GCVE-0-2025-57701)

    Vulnerability from cvelistv5 – Published: 2025-08-18 06:41 – Updated: 2025-08-19 00:17
    VLAI
    Title
    Reflected Cross-site Scripting in DIAEnergie
    Summary
    DIAEnergie - Reflected Cross-site Scripting
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
    Assigner
    Impacted products
    Vendor Product Version
    Delta Electronics DIAEnergie Affected: 0 , ≤ 1.11.00.002 (custom)
    Create a notification for this product.
    Date Public
    2025-08-18 06:25
    Credits
    Alex Williams of Converge Technology Solutions Cale Black of VulnCheck
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-57701",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-08-18T15:21:30.427149Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-08-18T15:21:39.485Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Windows"
              ],
              "product": "DIAEnergie",
              "vendor": "Delta Electronics",
              "versions": [
                {
                  "lessThanOrEqual": "1.11.00.002",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Alex Williams of Converge Technology Solutions"
            },
            {
              "lang": "en",
              "type": "coordinator",
              "value": "Cale Black of VulnCheck"
            }
          ],
          "datePublic": "2025-08-18T06:25:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDIAEnergie\u003c/span\u003e\u0026nbsp;- Reflected Cross-site Scripting"
                }
              ],
              "value": "DIAEnergie\u00a0- Reflected Cross-site Scripting"
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-591",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-591 Reflected XSS"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "HIGH",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 5.9,
                "baseSeverity": "MEDIUM",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "PASSIVE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:H/AT:N/PR:L/UI:P/VC:H/VI:L/VA:N/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "LOW",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-79",
                  "description": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-08-19T00:17:16.498Z",
            "orgId": "759f5e80-c8e1-4224-bead-956d7b33c98b",
            "shortName": "Deltaww"
          },
          "references": [
            {
              "url": "https://filecenter.deltaww.com/news/download/doc/Delta-PCSA-2025-00012_DIAEnergie%20Cross-Site%20Scripting%20Vulnerabilities.pdf"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Users are recommended to update DIAEnergie to v1.11.01.001 or later.\n\n\u003cbr\u003e"
                }
              ],
              "value": "Users are recommended to update DIAEnergie to v1.11.01.001 or later."
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "Reflected Cross-site Scripting in DIAEnergie",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "759f5e80-c8e1-4224-bead-956d7b33c98b",
        "assignerShortName": "Deltaww",
        "cveId": "CVE-2025-57701",
        "datePublished": "2025-08-18T06:41:55.539Z",
        "dateReserved": "2025-08-18T05:55:23.398Z",
        "dateUpdated": "2025-08-19T00:17:16.498Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-57700 (GCVE-0-2025-57700)

    Vulnerability from cvelistv5 – Published: 2025-08-18 06:28 – Updated: 2025-08-19 00:16
    VLAI
    Title
    Stored Cross-site Scripting in DIAEnergie
    Summary
    DIAEnergie - Stored Cross-site Scripting
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
    Assigner
    Impacted products
    Vendor Product Version
    Delta Electronics DIAEnergie Affected: 0 , ≤ 1.11.00.002 (custom)
    Create a notification for this product.
    Date Public
    2025-08-18 06:25
    Credits
    Alex Williams of Converge Technology Solutions Cale Black of VulnCheck
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-57700",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-08-18T15:26:23.762882Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-08-18T15:27:33.322Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "platforms": [
                "Windows"
              ],
              "product": "DIAEnergie",
              "vendor": "Delta Electronics",
              "versions": [
                {
                  "lessThanOrEqual": "1.11.00.002",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Alex Williams of Converge Technology Solutions"
            },
            {
              "lang": "en",
              "type": "coordinator",
              "value": "Cale Black of VulnCheck"
            }
          ],
          "datePublic": "2025-08-18T06:25:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDIAEnergie\u003c/span\u003e\u0026nbsp;- Stored Cross-site Scripting"
                }
              ],
              "value": "DIAEnergie\u00a0- Stored Cross-site Scripting"
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-592",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-592 Stored XSS"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 7,
                "baseSeverity": "HIGH",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "PASSIVE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:P/VC:H/VI:L/VA:N/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "LOW",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-79",
                  "description": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-08-19T00:16:18.111Z",
            "orgId": "759f5e80-c8e1-4224-bead-956d7b33c98b",
            "shortName": "Deltaww"
          },
          "references": [
            {
              "url": "https://filecenter.deltaww.com/news/download/doc/Delta-PCSA-2025-00012_DIAEnergie%20Cross-Site%20Scripting%20Vulnerabilities.pdf"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Users are recommended to update DIAEnergie to v1.11.01.001 or later.\n\n\u003cbr\u003e"
                }
              ],
              "value": "Users are recommended to update DIAEnergie to v1.11.01.001 or later."
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "Stored Cross-site Scripting in DIAEnergie",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "759f5e80-c8e1-4224-bead-956d7b33c98b",
        "assignerShortName": "Deltaww",
        "cveId": "CVE-2025-57700",
        "datePublished": "2025-08-18T06:28:55.514Z",
        "dateReserved": "2025-08-18T05:55:23.397Z",
        "dateUpdated": "2025-08-19T00:16:18.111Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-42417 (GCVE-0-2024-42417)

    Vulnerability from cvelistv5 – Published: 2024-10-03 22:32 – Updated: 2024-10-04 14:14
    VLAI
    Title
    Delta Electronics DIAEnergie SQL Injection
    Summary
    Delta Electronics DIAEnergie is vulnerable to an SQL injection in the script Handler_CFG.ashx. An authenticated attacker may be able to exploit this issue to cause delay in the targeted product.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    Impacted products
    Vendor Product Version
    Delta Electronics DIAEnergie Affected: 0 , ≤ v1.10.01.008 (custom)
    Create a notification for this product.
    deltaww diaenergie Affected: 0 , ≤ 1.10.01.008 (custom)
        cpe:2.3:a:deltaww:diaenergie:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Credits
    Michael Heinzl reported these vulnerabilities to CISA.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:deltaww:diaenergie:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "diaenergie",
                "vendor": "deltaww",
                "versions": [
                  {
                    "lessThanOrEqual": "1.10.01.008",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-42417",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-10-04T14:12:45.958174Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-10-04T14:14:32.287Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "DIAEnergie",
              "vendor": "Delta Electronics",
              "versions": [
                {
                  "lessThanOrEqual": "v1.10.01.008",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Michael Heinzl reported these vulnerabilities to CISA."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta Electronics DIAEnergie is vulnerable to an SQL injection in the script Handler_CFG.ashx. An authenticated attacker may be able to exploit this issue to cause delay in the targeted product.\u003c/span\u003e\n\n\u003c/span\u003e"
                }
              ],
              "value": "Delta Electronics DIAEnergie is vulnerable to an SQL injection in the script Handler_CFG.ashx. An authenticated attacker may be able to exploit this issue to cause delay in the targeted product."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "privilegesRequired": "LOW",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-89",
                  "description": "CWE-89 SQL Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-10-03T22:32:59.999Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-277-03"
            },
            {
              "url": "https://www.deltaww.com/en-US/Cybersecurity_Advisory"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eDelta recommends users update to DIAEnergie v1.10.01.009. Users can request this version of DIAEnergie from \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.deltaww.com/en-US/customerService\"\u003eDelta Electronics\u0027 regional sales or agents.\u003c/a\u003e\u003c/p\u003e\u003cp\u003eFor more information on this issue, please see the \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.deltaww.com/en-US/Cybersecurity_Advisory\"\u003eDelta product cybersecurity advisory.\u003c/a\u003e\u003c/p\u003e\n\n\u003cbr\u003e"
                }
              ],
              "value": "Delta recommends users update to DIAEnergie v1.10.01.009. Users can request this version of DIAEnergie from  Delta Electronics\u0027 regional sales or agents. https://www.deltaww.com/en-US/customerService \n\nFor more information on this issue, please see the  Delta product cybersecurity advisory. https://www.deltaww.com/en-US/Cybersecurity_Advisory"
            }
          ],
          "source": {
            "advisory": "ICSA-24-277-03",
            "discovery": "EXTERNAL"
          },
          "title": "Delta Electronics DIAEnergie SQL Injection",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2024-42417",
        "datePublished": "2024-10-03T22:32:59.999Z",
        "dateReserved": "2024-10-01T17:18:54.590Z",
        "dateUpdated": "2024-10-04T14:14:32.287Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-43699 (GCVE-0-2024-43699)

    Vulnerability from cvelistv5 – Published: 2024-10-03 22:28 – Updated: 2024-10-04 14:15
    VLAI
    Title
    Delta Electronics DIAEnergie SQL Injection
    Summary
    Delta Electronics DIAEnergie is vulnerable to an SQL injection in the script AM_RegReport.aspx. An unauthenticated attacker may be able to exploit this issue to obtain records contained in the targeted product.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    Impacted products
    Vendor Product Version
    Delta Electronics DIAEnergie Affected: 0 , ≤ v1.10.01.008 (custom)
    Create a notification for this product.
    deltaww diaenergie Affected: 0 , ≤ 1.10.01.008 (custom)
        cpe:2.3:a:deltaww:diaenergie:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Credits
    Michael Heinzl reported these vulnerabilities to CISA.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:deltaww:diaenergie:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unaffected",
                "product": "diaenergie",
                "vendor": "deltaww",
                "versions": [
                  {
                    "lessThanOrEqual": "1.10.01.008",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-43699",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-10-04T14:14:50.609579Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-10-04T14:15:27.750Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "DIAEnergie",
              "vendor": "Delta Electronics",
              "versions": [
                {
                  "lessThanOrEqual": "v1.10.01.008",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Michael Heinzl reported these vulnerabilities to CISA."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta Electronics DIAEnergie is vulnerable to an SQL injection in the script AM_RegReport.aspx. An unauthenticated attacker may be able to exploit this issue to obtain records contained in the targeted product.\u003c/span\u003e"
                }
              ],
              "value": "Delta Electronics DIAEnergie is vulnerable to an SQL injection in the script AM_RegReport.aspx. An unauthenticated attacker may be able to exploit this issue to obtain records contained in the targeted product."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 9.3,
                "baseSeverity": "CRITICAL",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-89",
                  "description": "CWE-89 SQL Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-10-03T22:28:35.364Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-277-03"
            },
            {
              "url": "https://www.deltaww.com/en-US/Cybersecurity_Advisory"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eDelta recommends users update to DIAEnergie v1.10.01.009. Users can request this version of DIAEnergie from \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.deltaww.com/en-US/customerService\"\u003eDelta Electronics\u0027 regional sales or agents.\u003c/a\u003e\u003c/p\u003e\u003cp\u003eFor more information on this issue, please see the \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.deltaww.com/en-US/Cybersecurity_Advisory\"\u003eDelta product cybersecurity advisory.\u003c/a\u003e\u003c/p\u003e\n\n\u003cbr\u003e"
                }
              ],
              "value": "Delta recommends users update to DIAEnergie v1.10.01.009. Users can request this version of DIAEnergie from  Delta Electronics\u0027 regional sales or agents. https://www.deltaww.com/en-US/customerService \n\nFor more information on this issue, please see the  Delta product cybersecurity advisory. https://www.deltaww.com/en-US/Cybersecurity_Advisory"
            }
          ],
          "source": {
            "advisory": "ICSA-24-277-03",
            "discovery": "EXTERNAL"
          },
          "title": "Delta Electronics DIAEnergie SQL Injection",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2024-43699",
        "datePublished": "2024-10-03T22:28:35.364Z",
        "dateReserved": "2024-10-01T17:18:54.603Z",
        "dateUpdated": "2024-10-04T14:15:27.750Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-4549 (GCVE-0-2024-4549)

    Vulnerability from cvelistv5 – Published: 2024-05-06 13:54 – Updated: 2024-08-01 20:47
    VLAI
    Title
    Delta Electronics DIAEnergie SQL Injection
    Summary
    A denial of service vulnerability exists in Delta Electronics DIAEnergie v1.10.1.8610 and prior. When processing an 'ICS Restart!' message, CEBC.exe restarts the system.
    SSVC
    Exploitation: poc Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-400 - Uncontrolled Resource Consumption
    Assigner
    Impacted products
    Vendor Product Version
    Delta Electronics DIAEnergie Affected: 0 , ≤ 1.10.1.8610 (custom)
    Create a notification for this product.
    deltaww diaenergie Affected: 0 , ≤ 1.10.1.8610 (custom)
        cpe:2.3:a:deltaww:diaenergie:-:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:deltaww:diaenergie:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "diaenergie",
                "vendor": "deltaww",
                "versions": [
                  {
                    "lessThanOrEqual": "1.10.1.8610",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-4549",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-05-06T15:35:29.745502Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-400",
                    "description": "CWE-400 Uncontrolled Resource Consumption",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-06-20T20:08:39.537Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-01T20:47:41.185Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.tenable.com/security/research/tra-2024-13"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "DIAEnergie",
              "vendor": "Delta Electronics",
              "versions": [
                {
                  "lessThanOrEqual": "1.10.1.8610",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "A denial of service vulnerability exists in Delta Electronics DIAEnergie v1.10.1.8610 and prior. When processing an \u0027ICS Restart!\u0027 message, CEBC.exe restarts the system."
                }
              ],
              "value": "A denial of service vulnerability exists in Delta Electronics DIAEnergie v1.10.1.8610 and prior. When processing an \u0027ICS Restart!\u0027 message, CEBC.exe restarts the system."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-05-06T20:47:40.285Z",
            "orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
            "shortName": "tenable"
          },
          "references": [
            {
              "url": "https://www.tenable.com/security/research/tra-2024-13"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Delta Electronics DIAEnergie SQL Injection ",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
        "assignerShortName": "tenable",
        "cveId": "CVE-2024-4549",
        "datePublished": "2024-05-06T13:54:32.808Z",
        "dateReserved": "2024-05-06T13:35:44.109Z",
        "dateUpdated": "2024-08-01T20:47:41.185Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-4548 (GCVE-0-2024-4548)

    Vulnerability from cvelistv5 – Published: 2024-05-06 13:51 – Updated: 2024-08-01 20:47
    VLAI
    Title
    Delta Electronics DIAEnergie SQL Injection
    Summary
    An SQLi vulnerability exists in Delta Electronics DIAEnergie v1.10.1.8610 and prior when CEBC.exe processes a 'RecalculateHDMWYC' message, which is split into 4 fields using the '~' character as the separator. An unauthenticated remote attacker can perform SQLi via the fourth field.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-20 - Improper Input Validation
    Assigner
    Impacted products
    Vendor Product Version
    Delta Electronics DIAEnergie Affected: 0 , ≤ 1.10.1.8610 (custom)
    Create a notification for this product.
    deltaww diaenergie Affected: 0 , ≤ 1.10.1.8610 (custom)
        cpe:2.3:a:deltaww:diaenergie:-:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:deltaww:diaenergie:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "diaenergie",
                "vendor": "deltaww",
                "versions": [
                  {
                    "lessThanOrEqual": "1.10.1.8610",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-4548",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-05-13T13:41:00.312856Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-06-20T20:06:39.622Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-01T20:47:40.056Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.tenable.com/security/research/tra-2024-13"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "DIAEnergie",
              "vendor": "Delta Electronics",
              "versions": [
                {
                  "lessThanOrEqual": "1.10.1.8610",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "An SQLi vulnerability exists in\u0026nbsp;Delta Electronics DIAEnergie v1.10.1.8610 and prior when CEBC.exe processes a \u0027RecalculateHDMWYC\u0027 message, which is split into 4 fields using the \u0027~\u0027 character as the separator. An unauthenticated remote attacker can perform SQLi via the fourth field."
                }
              ],
              "value": "An SQLi vulnerability exists in\u00a0Delta Electronics DIAEnergie v1.10.1.8610 and prior when CEBC.exe processes a \u0027RecalculateHDMWYC\u0027 message, which is split into 4 fields using the \u0027~\u0027 character as the separator. An unauthenticated remote attacker can perform SQLi via the fourth field."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-66",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-66 SQL Injection"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-20",
                  "description": "CWE-20 Improper Input Validation",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-05-06T13:51:07.049Z",
            "orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
            "shortName": "tenable"
          },
          "references": [
            {
              "url": "https://www.tenable.com/security/research/tra-2024-13"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Delta Electronics DIAEnergie SQL Injection",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
        "assignerShortName": "tenable",
        "cveId": "CVE-2024-4548",
        "datePublished": "2024-05-06T13:51:07.049Z",
        "dateReserved": "2024-05-06T13:35:43.319Z",
        "dateUpdated": "2024-08-01T20:47:40.056Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-4547 (GCVE-0-2024-4547)

    Vulnerability from cvelistv5 – Published: 2024-05-06 13:48 – Updated: 2024-08-01 20:47
    VLAI
    Title
    Delta Electronics DIAEnergie Unauthenticated SQL Injection
    Summary
    A SQLi vulnerability exists in Delta Electronics DIAEnergie v1.10.1.8610 and prior when CEBC.exe processes a 'RecalculateScript' message, which is splitted into 4 fields using the '~' character as the separator. An unauthenticated remote attacker can perform SQLi via the fourth field
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-20 - Improper Input Validation
    Assigner
    Impacted products
    Vendor Product Version
    Delta Electronics DIAEnergie Affected: 0 , ≤ 1.10.1.8610 (custom)
    Create a notification for this product.
    deltaww diaenergie Affected: - , ≤ 1.10.1.8610 (custom)
        cpe:2.3:a:deltaww:diaenergie:-:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:deltaww:diaenergie:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "diaenergie",
                "vendor": "deltaww",
                "versions": [
                  {
                    "lessThanOrEqual": "1.10.1.8610",
                    "status": "affected",
                    "version": "-",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-4547",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-05-06T18:33:49.309166Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-06-20T20:08:45.951Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-01T20:47:40.554Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.tenable.com/security/research/tra-2024-13"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "DIAEnergie",
              "vendor": "Delta Electronics",
              "versions": [
                {
                  "lessThanOrEqual": "1.10.1.8610",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "A SQLi vulnerability exists in\u0026nbsp;Delta Electronics\u0026nbsp;DIAEnergie v1.10.1.8610 and prior when CEBC.exe processes a \u0027RecalculateScript\u0027 message, which is splitted into 4 fields using the \u0027~\u0027 character as the separator. An unauthenticated remote attacker can perform SQLi via the fourth field"
                }
              ],
              "value": "A SQLi vulnerability exists in\u00a0Delta Electronics\u00a0DIAEnergie v1.10.1.8610 and prior when CEBC.exe processes a \u0027RecalculateScript\u0027 message, which is splitted into 4 fields using the \u0027~\u0027 character as the separator. An unauthenticated remote attacker can perform SQLi via the fourth field"
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-66",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-66 SQL Injection"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-20",
                  "description": "CWE-20 Improper Input Validation",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-05-06T13:48:08.737Z",
            "orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
            "shortName": "tenable"
          },
          "references": [
            {
              "url": "https://www.tenable.com/security/research/tra-2024-13"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Delta Electronics DIAEnergie Unauthenticated SQL Injection",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
        "assignerShortName": "tenable",
        "cveId": "CVE-2024-4547",
        "datePublished": "2024-05-06T13:48:08.737Z",
        "dateReserved": "2024-05-06T13:35:42.505Z",
        "dateUpdated": "2024-08-01T20:47:40.554Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-34033 (GCVE-0-2024-34033)

    Vulnerability from cvelistv5 – Published: 2024-05-03 00:20 – Updated: 2024-08-12 20:08
    VLAI
    Title
    Path Traversal vulnerability in Delta Electronics DIAEnergie
    Summary
    Delta Electronics DIAEnergie has insufficient input validation which makes it possible to perform a path traversal attack and write outside of the intended directory. If a file name is specified that already exists on the file system, then the original file will be overwritten.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
    Assigner
    References
    Impacted products
    Vendor Product Version
    Delta Electronics DIAEnergie Affected: 1.10.00.005
    Create a notification for this product.
    deltaww diaenergie Affected: 0 , < 1.10.01.004 (custom)
        cpe:2.3:a:deltaww:diaenergie:-:*:*:*:*:*:*:*
    Create a notification for this product.
    Credits
    Michael Heinzl reported these vulnerabilities to CISA.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:deltaww:diaenergie:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "diaenergie",
                "vendor": "deltaww",
                "versions": [
                  {
                    "lessThan": "1.10.01.004",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-34033",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-06-26T17:53:32.429375Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-08-12T20:08:16.443Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T02:42:59.870Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "government-resource",
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-123-02"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "DIAEnergie ",
              "vendor": "Delta Electronics",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.10.00.005"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Michael Heinzl reported these vulnerabilities to CISA."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta Electronics DIAEnergie has insufficient input validation which makes it possible to perform a path traversal attack and write outside of the intended directory. If a file name is specified that already exists on the file system, then the original file will be overwritten.\u003c/span\u003e\n\n\u003c/span\u003e\n\n\u003c/span\u003e\n\n"
                }
              ],
              "value": "\nDelta Electronics DIAEnergie has insufficient input validation which makes it possible to perform a path traversal attack and write outside of the intended directory. If a file name is specified that already exists on the file system, then the original file will be overwritten.\n\n"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-22",
                  "description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-05-03T00:20:03.319Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-123-02"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta Electronics recommends users update to DIAEnergie v1.10.01.004 to mitigate these vulnerabilities. Users can request this version of DIAEnergie from Delta Electronics\u0027 regional sales or agents.\u003c/span\u003e\n\n\u003cbr\u003e"
                }
              ],
              "value": "\nDelta Electronics recommends users update to DIAEnergie v1.10.01.004 to mitigate these vulnerabilities. Users can request this version of DIAEnergie from Delta Electronics\u0027 regional sales or agents.\n\n"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Path Traversal vulnerability in Delta Electronics DIAEnergie ",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2024-34033",
        "datePublished": "2024-05-03T00:20:03.319Z",
        "dateReserved": "2024-04-29T17:56:18.036Z",
        "dateUpdated": "2024-08-12T20:08:16.443Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-34031 (GCVE-0-2024-34031)

    Vulnerability from cvelistv5 – Published: 2024-05-03 00:18 – Updated: 2024-08-12 20:09
    VLAI
    Title
    SQL Injection vulnerability in Delta Electronics DIAEnergie
    Summary
    Delta Electronics DIAEnergie is vulnerable to an SQL injection vulnerability that exists in the script Handler_CFG.ashx. An authenticated attacker can exploit this issue to potentially compromise the system on which DIAEnergie is deployed.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') CWE-89
    Assigner
    References
    Impacted products
    Vendor Product Version
    Delta Electronics DIAEnergie Affected: 1.10.00.005
    Create a notification for this product.
    deltaww diaenergie Affected: 1.10.00.005
        cpe:2.3:a:deltaww:diaenergie:1.10.00.005:*:*:*:*:*:*:*
    Create a notification for this product.
    Credits
    Michael Heinzl reported these vulnerabilities to CISA.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:deltaww:diaenergie:1.10.00.005:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "diaenergie",
                "vendor": "deltaww",
                "versions": [
                  {
                    "status": "affected",
                    "version": "1.10.00.005"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-34031",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-06-25T19:07:57.188972Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-08-12T20:09:18.872Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T02:42:59.938Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "government-resource",
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-123-02"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "DIAEnergie ",
              "vendor": "Delta Electronics",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.10.00.005"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Michael Heinzl reported these vulnerabilities to CISA."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta Electronics DIAEnergie is vulnerable to an SQL injection vulnerability that exists in the script Handler_CFG.ashx. An authenticated attacker can exploit this issue to potentially compromise the system on which DIAEnergie is deployed.\u003c/span\u003e\n\n"
                }
              ],
              "value": "\nDelta Electronics DIAEnergie is vulnerable to an SQL injection vulnerability that exists in the script Handler_CFG.ashx. An authenticated attacker can exploit this issue to potentially compromise the system on which DIAEnergie is deployed.\n\n"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-89",
                  "description": " Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027) CWE-89",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-05-03T00:18:13.497Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-123-02"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta Electronics recommends users update to DIAEnergie v1.10.01.004 to mitigate these vulnerabilities. Users can request this version of DIAEnergie from Delta Electronics\u0027 regional sales or agents.\u003c/span\u003e\n\n\u003cbr\u003e"
                }
              ],
              "value": "\nDelta Electronics recommends users update to DIAEnergie v1.10.01.004 to mitigate these vulnerabilities. Users can request this version of DIAEnergie from Delta Electronics\u0027 regional sales or agents.\n\n"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": " SQL Injection vulnerability in Delta Electronics DIAEnergie ",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2024-34031",
        "datePublished": "2024-05-03T00:18:13.497Z",
        "dateReserved": "2024-04-29T17:56:18.035Z",
        "dateUpdated": "2024-08-12T20:09:18.872Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-34032 (GCVE-0-2024-34032)

    Vulnerability from cvelistv5 – Published: 2024-05-03 00:16 – Updated: 2024-08-12 20:08
    VLAI
    Title
    SQL Injection in Delta Electronics DIAEnergie
    Summary
    Delta Electronics DIAEnergie is vulnerable to an SQL injection vulnerability that exists in the GetDIACloudList endpoint. An authenticated attacker can exploit this issue to potentially compromise the system on which DIAEnergie is deployed.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') CWE-89
    Assigner
    References
    Impacted products
    Vendor Product Version
    Delta Electronics DIAEnergie Affected: 1.10.00.005
    Create a notification for this product.
    deltaww diaenergie Affected: 0
        cpe:2.3:a:deltaww:diaenergie:-:*:*:*:*:*:*:*
    Create a notification for this product.
    Credits
    Michael Heinzl reported these vulnerabilities to CISA.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:deltaww:diaenergie:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "diaenergie",
                "vendor": "deltaww",
                "versions": [
                  {
                    "status": "affected",
                    "version": "0"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-34032",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-06-25T19:09:34.838148Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-08-12T20:08:42.943Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T02:42:59.827Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "government-resource",
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-123-02"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "DIAEnergie ",
              "vendor": "Delta Electronics",
              "versions": [
                {
                  "status": "affected",
                  "version": "1.10.00.005"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Michael Heinzl reported these vulnerabilities to CISA."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta Electronics DIAEnergie is vulnerable to an SQL injection vulnerability that exists in the GetDIACloudList endpoint. An authenticated attacker can exploit this issue to potentially compromise the system on which DIAEnergie is deployed.\u003c/span\u003e\n\n\u003c/span\u003e\n\n"
                }
              ],
              "value": "\nDelta Electronics DIAEnergie is vulnerable to an SQL injection vulnerability that exists in the GetDIACloudList endpoint. An authenticated attacker can exploit this issue to potentially compromise the system on which DIAEnergie is deployed.\n\n"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-89",
                  "description": " Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027) CWE-89",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-05-03T00:16:40.017Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "tags": [
                "government-resource"
              ],
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-123-02"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta Electronics recommends users update to DIAEnergie v1.10.01.004 to mitigate these vulnerabilities. Users can request this version of DIAEnergie from Delta Electronics\u0027 regional sales or agents.\u003c/span\u003e\n\n\u003cbr\u003e"
                }
              ],
              "value": "\nDelta Electronics recommends users update to DIAEnergie v1.10.01.004 to mitigate these vulnerabilities. Users can request this version of DIAEnergie from Delta Electronics\u0027 regional sales or agents.\n\n"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "SQL Injection in Delta Electronics DIAEnergie ",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2024-34032",
        "datePublished": "2024-05-03T00:16:40.017Z",
        "dateReserved": "2024-04-29T17:56:18.036Z",
        "dateUpdated": "2024-08-12T20:08:42.943Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2024-25574 (GCVE-0-2024-25574)

    Vulnerability from cvelistv5 – Published: 2024-04-01 16:04 – Updated: 2024-08-01 23:44
    VLAI
    Title
    Delta Electronics DIAEnergie SQL Injection
    Summary
    SQL injection vulnerability exists in GetDIAE_usListParameters.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    Impacted products
    Vendor Product Version
    Delta Electronics DIAEnergie Affected: 0 , < v1.10.00.005 (custom)
    Create a notification for this product.
    deltaww diaenergie Affected: 0 , < 1.10.00.005 (custom)
        cpe:2.3:a:deltaww:diaenergie:-:*:*:*:*:*:*:*
    Create a notification for this product.
    Date Public
    2024-03-14 17:00
    Credits
    Michael Heinzl reported these vulnerabilities to CISA.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:deltaww:diaenergie:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "diaenergie",
                "vendor": "deltaww",
                "versions": [
                  {
                    "lessThan": "1.10.00.005",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-25574",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-04-01T17:13:46.607653Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-06-20T20:09:02.248Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-01T23:44:09.659Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-074-12"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "DIAEnergie",
              "vendor": "Delta Electronics",
              "versions": [
                {
                  "lessThan": "v1.10.00.005",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Michael Heinzl reported these vulnerabilities to CISA."
            }
          ],
          "datePublic": "2024-03-14T17:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\nSQL injection vulnerability exists in GetDIAE_usListParameters.\n\n\u003c/span\u003e\n\n"
                }
              ],
              "value": "\nSQL injection vulnerability exists in GetDIAE_usListParameters.\n\n"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-89",
                  "description": "CWE-89 SQL Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-04-01T16:04:46.800Z",
            "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
            "shortName": "icscert"
          },
          "references": [
            {
              "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-074-12"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDelta recommends users update to DIAEnergie v1.10.00.005. Users can request this version of DIAEnergie from \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.deltaww.com/en/customerService\"\u003eDelta Electronics\u0027 regional sales or agents\u003c/a\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e.\u003c/span\u003e\n\n\u003cbr\u003e"
                }
              ],
              "value": "\nDelta recommends users update to DIAEnergie v1.10.00.005. Users can request this version of DIAEnergie from  Delta Electronics\u0027 regional sales or agents https://www.deltaww.com/en/customerService .\n\n"
            }
          ],
          "source": {
            "advisory": "ICSA-24-074-12",
            "discovery": "EXTERNAL"
          },
          "title": "Delta Electronics DIAEnergie SQL Injection",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "assignerShortName": "icscert",
        "cveId": "CVE-2024-25574",
        "datePublished": "2024-04-01T16:04:46.800Z",
        "dateReserved": "2024-03-12T15:07:02.593Z",
        "dateUpdated": "2024-08-01T23:44:09.659Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",