Search

Find a vulnerability

Search criteria

    10 vulnerabilities found for Compact Controller CC100 (751-9301) by WAGO

    CVE-2022-45140 (GCVE-0-2022-45140)

    Vulnerability from nvd – Published: 2023-02-27 14:36 – Updated: 2025-03-10 17:46
    VLAI
    Title
    WAGO: Missing Authentication for Critical Function
    Summary
    The configuration backend allows an unauthenticated user to write arbitrary data with root privileges to the storage, which could lead to unauthenticated remote code execution and full system compromise.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-306 - Missing Authentication for Critical Function
    Assigner
    References
    Impacted products
    Vendor Product Version
    WAGO Compact Controller CC100 (751-9301) Affected: FW16 , < FW22 (custom)
    Unaffected: FW22 Patch 1
    Affected: FW23
    Create a notification for this product.
    WAGO Edge Controller (752-8303/8000-002) Affected: FW16 , < FW22 (custom)
    Unaffected: FW22 Patch 1
    Affected: FW23
    Create a notification for this product.
    WAGO PFC100 (750-81xx/xxx-xxx) Affected: FW16 , < FW22 (custom)
    Unaffected: FW22 Patch 1
    Affected: FW23
    Create a notification for this product.
    WAGO PFC200 (750-82xx/xxx-xxx) Affected: FW16 , < FW22 (custom)
    Unaffected: FW22 Patch 1
    Affected: FW23
    Create a notification for this product.
    WAGO Touch Panel 600 Advanced Line (762-5xxx) Affected: FW16 , < FW22 (custom)
    Unaffected: FW22 Patch 1
    Affected: FW23
    Create a notification for this product.
    WAGO Touch Panel 600 Marine Line (762-6xxx) Affected: FW16 , < FW22 (custom)
    Unaffected: FW22 Patch 1
    Affected: FW23
    Create a notification for this product.
    WAGO Touch Panel 600 Standard Line (762-4xxx) Affected: FW16 , < FW22 (custom)
    Unaffected: FW22 Patch 1
    Affected: FW23
    Create a notification for this product.
    Credits
    Ryan Pickren of Georgia Institute of Technologys Cyber-Physical Security Lab
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T14:09:55.436Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert.vde.com/en/advisories/VDE-2022-060/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-45140",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-03-10T17:46:43.476712Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-03-10T17:46:52.078Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Compact Controller CC100 (751-9301)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "FW22 Patch 1"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Edge Controller (752-8303/8000-002)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "FW22 Patch 1"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "PFC100 (750-81xx/xxx-xxx)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "FW22 Patch 1"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "PFC200 (750-82xx/xxx-xxx)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "FW22 Patch 1"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Touch Panel 600 Advanced Line (762-5xxx)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "FW22 Patch 1"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Touch Panel 600 Marine Line (762-6xxx)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "FW22 Patch 1"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Touch Panel 600 Standard Line (762-4xxx)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "FW22 Patch 1"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Ryan Pickren of Georgia Institute of Technologys Cyber-Physical Security Lab"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "The configuration backend allows an unauthenticated user to write arbitrary data with root privileges to the storage, which could lead to unauthenticated remote code execution and full system compromise."
                }
              ],
              "value": "The configuration backend allows an unauthenticated user to write arbitrary data with root privileges to the storage, which could lead to unauthenticated remote code execution and full system compromise."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-115",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-115 Authentication Bypass"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-306",
                  "description": "CWE-306 Missing Authentication for Critical Function",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-02-27T14:36:39.448Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://cert.vde.com/en/advisories/VDE-2022-060/"
            }
          ],
          "source": {
            "defect": [
              "CERT@VDE#64160"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "WAGO: Missing Authentication for Critical Function ",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2022-45140",
        "datePublished": "2023-02-27T14:36:39.448Z",
        "dateReserved": "2022-11-10T09:46:59.080Z",
        "dateUpdated": "2025-03-10T17:46:52.078Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-45139 (GCVE-0-2022-45139)

    Vulnerability from nvd – Published: 2023-02-27 14:36 – Updated: 2025-03-10 17:46
    VLAI
    Title
    WAGO: Origin validation error through CORS misconfiguration
    Summary
    A CORS Misconfiguration in the web-based management allows a malicious third party webserver to misuse all basic information pages on the webserver. In combination with CVE-2022-45138 this could lead to disclosure of device information like CPU diagnostics. As there is just a limited amount of information readable the impact only affects a small subset of confidentiality.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-346 - Origin Validation Error
    Assigner
    References
    Impacted products
    Vendor Product Version
    WAGO Compact Controller CC100 (751-9301) Affected: FW16 , < FW22 (custom)
    Unaffected: FW22 Patch 1
    Affected: FW23
    Create a notification for this product.
    WAGO Edge Controller (752-8303/8000-002) Affected: FW18 , < FW22 (custom)
    Unaffected: FW22 Patch 1
    Affected: FW23
    Create a notification for this product.
    WAGO PFC100 (750-81xx/xxx-xxx) Affected: FW16 , < FW22 (custom)
    Unaffected: FW22 Patch 1
    Affected: FW23
    Create a notification for this product.
    WAGO PFC200 (750-82xx/xxx-xxx) Affected: FW16 , < FW22 (custom)
    Unaffected: FW22 Patch 1
    Affected: FW23
    Create a notification for this product.
    WAGO Touch Panel 600 Advanced Line (762-5xxx) Affected: FW16 , < FW22 (custom)
    Unaffected: FW22 Patch 1
    Affected: FW23
    Create a notification for this product.
    WAGO Touch Panel 600 Marine Line (762-6xxx) Affected: FW16 , < FW22 (custom)
    Unaffected: FW22 Patch 1
    Affected: FW23
    Create a notification for this product.
    WAGO Touch Panel 600 Standard Line (762-4xxx) Affected: FW16 , < FW22 (custom)
    Unaffected: FW22 Patch 1
    Affected: FW23
    Create a notification for this product.
    Credits
    Ryan Pickren of Georgia Institute of Technologys Cyber-Physical Security Lab
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T14:09:55.406Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert.vde.com/en/advisories/VDE-2022-060/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-45139",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-03-10T17:45:54.261351Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-03-10T17:46:16.888Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Compact Controller CC100 (751-9301)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "FW22 Patch 1"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Edge Controller (752-8303/8000-002)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW18",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "FW22 Patch 1"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "PFC100 (750-81xx/xxx-xxx)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "FW22 Patch 1"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "PFC200 (750-82xx/xxx-xxx)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "FW22 Patch 1"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Touch Panel 600 Advanced Line (762-5xxx)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "FW22 Patch 1"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Touch Panel 600 Marine Line (762-6xxx)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "FW22 Patch 1"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Touch Panel 600 Standard Line (762-4xxx)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "FW22 Patch 1"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Ryan Pickren of Georgia Institute of Technologys Cyber-Physical Security Lab"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "A CORS Misconfiguration in the web-based management allows a malicious third party webserver to misuse all basic information pages on the webserver. In combination with CVE-2022-45138 this could lead to disclosure of device information like CPU diagnostics. As there is just a limited amount of information readable the impact only affects a small subset of confidentiality."
                }
              ],
              "value": "A CORS Misconfiguration in the web-based management allows a malicious third party webserver to misuse all basic information pages on the webserver. In combination with CVE-2022-45138 this could lead to disclosure of device information like CPU diagnostics. As there is just a limited amount of information readable the impact only affects a small subset of confidentiality."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-554",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-554 Functionality Bypass"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-346",
                  "description": "CWE-346 Origin Validation Error",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-02-27T14:36:32.016Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://cert.vde.com/en/advisories/VDE-2022-060/"
            }
          ],
          "source": {
            "defect": [
              "CERT@VDE#64160"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "WAGO: Origin validation error through CORS misconfiguration",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2022-45139",
        "datePublished": "2023-02-27T14:36:32.016Z",
        "dateReserved": "2022-11-10T09:46:59.080Z",
        "dateUpdated": "2025-03-10T17:46:16.888Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-45138 (GCVE-0-2022-45138)

    Vulnerability from nvd – Published: 2023-02-27 14:36 – Updated: 2025-03-10 17:20
    VLAI
    Title
    WAGO: Missing Authentication for Critical Function
    Summary
    The configuration backend of the web-based management can be used by unauthenticated users, although only authenticated users should be able to use the API. The vulnerability allows an unauthenticated attacker to read and set several device parameters that can lead to full compromise of the device.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-306 - Missing Authentication for Critical Function
    Assigner
    References
    Impacted products
    Vendor Product Version
    WAGO Compact Controller CC100 (751-9301) Affected: FW16 , < FW22 (custom)
    Unaffected: FW22 Patch 1
    Affected: FW23
    Create a notification for this product.
    WAGO Edge Controller (752-8303/8000-002) Affected: FW18 , < FW22 (custom)
    Unaffected: FW22 Patch 1
    Affected: FW23
    Create a notification for this product.
    WAGO PFC100 (750-81xx/xxx-xxx) Affected: FW16 , < FW22 (custom)
    Unaffected: FW22 Patch 1
    Affected: FW23
    Create a notification for this product.
    WAGO PFC200 (750-82xx/xxx-xxx) Affected: FW16 , < FW22 (custom)
    Unaffected: FW22 Patch 1
    Affected: FW23
    Create a notification for this product.
    WAGO Touch Panel 600 Advanced Line (762-5xxx) Affected: FW16 , < FW22 (custom)
    Unaffected: FW22 Patch 1
    Affected: FW23
    Create a notification for this product.
    WAGO Touch Panel 600 Marine Line (762-6xxx) Affected: FW16 , < FW22 (custom)
    Unaffected: FW22 Patch 1
    Affected: FW23
    Create a notification for this product.
    WAGO Touch Panel 600 Standard Line (762-4xxx) Affected: FW16 , < FW22 (custom)
    Unaffected: FW22 Patch 1
    Affected: FW23
    Create a notification for this product.
    Credits
    Ryan Pickren of Georgia Institute of Technologys Cyber-Physical Security Lab
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T14:09:55.415Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert.vde.com/en/advisories/VDE-2022-060/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-45138",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-03-10T17:20:33.215201Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-03-10T17:20:50.798Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Compact Controller CC100 (751-9301)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "FW22 Patch 1"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Edge Controller (752-8303/8000-002)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW18",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "FW22 Patch 1"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "PFC100 (750-81xx/xxx-xxx)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "FW22 Patch 1"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "PFC200 (750-82xx/xxx-xxx)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "FW22 Patch 1"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Touch Panel 600 Advanced Line (762-5xxx)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "FW22 Patch 1"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Touch Panel 600 Marine Line (762-6xxx)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "FW22 Patch 1"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Touch Panel 600 Standard Line (762-4xxx)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "FW22 Patch 1"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Ryan Pickren of Georgia Institute of Technologys Cyber-Physical Security Lab"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "The configuration backend of the web-based management can be used by unauthenticated users, although only authenticated users should be able to use the API. The vulnerability allows an unauthenticated attacker to read and set several device parameters that can lead to full compromise of the device."
                }
              ],
              "value": "The configuration backend of the web-based management can be used by unauthenticated users, although only authenticated users should be able to use the API. The vulnerability allows an unauthenticated attacker to read and set several device parameters that can lead to full compromise of the device."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-115",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-115 Authentication Bypass"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-306",
                  "description": "CWE-306 Missing Authentication for Critical Function",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-02-27T14:36:20.474Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://cert.vde.com/en/advisories/VDE-2022-060/"
            }
          ],
          "source": {
            "defect": [
              "CERT@VDE#64160"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "WAGO: Missing Authentication for Critical Function",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2022-45138",
        "datePublished": "2023-02-27T14:36:20.474Z",
        "dateReserved": "2022-11-10T09:46:59.079Z",
        "dateUpdated": "2025-03-10T17:20:50.798Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-45137 (GCVE-0-2022-45137)

    Vulnerability from nvd – Published: 2023-02-27 14:36 – Updated: 2024-08-03 14:09
    VLAI
    Title
    WAGO: Reflective Cross-Site Scripting
    Summary
    The configuration backend of the web-based management is vulnerable to reflected XSS (Cross-Site Scripting) attacks that targets the users browser. This leads to a limited impact of confidentiality and integrity but no impact of availability.
    CWE
    • CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
    Assigner
    References
    Impacted products
    Vendor Product Version
    WAGO Compact Controller CC100 (751-9301) Affected: FW16 , < FW22 (custom)
    Unaffected: FW22 Patch 1
    Affected: FW23
    Create a notification for this product.
    WAGO Edge Controller (752-8303/8000-002) Affected: FW18 , < FW22 (custom)
    Unaffected: FW22 Patch 1
    Affected: FW23
    Create a notification for this product.
    WAGO PFC100 (750-81xx/xxx-xxx) Affected: FW16 , < FW22 (custom)
    Unaffected: FW22 Patch 1
    Affected: FW23
    Create a notification for this product.
    WAGO PFC200 (750-82xx/xxx-xxx) Affected: FW16 , < FW22 (custom)
    Unaffected: FW22 Patch 1
    Affected: FW23
    Create a notification for this product.
    WAGO Touch Panel 600 Advanced Line (762-5xxx) Affected: FW16 , < FW22 (custom)
    Unaffected: FW22 Patch 1
    Affected: FW23
    Create a notification for this product.
    WAGO Touch Panel 600 Marine Line (762-6xxx) Affected: FW16 , < FW22 (custom)
    Unaffected: FW22 Patch 1
    Affected: FW23
    Create a notification for this product.
    WAGO Touch Panel 600 Standard Line (762-4xxx) Affected: FW16 , < FW22 (custom)
    Unaffected: FW22 Patch 1
    Affected: FW23
    Create a notification for this product.
    Credits
    Ryan Pickren of Georgia Institute of Technologys Cyber-Physical Security Lab
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T14:09:56.545Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert.vde.com/en/advisories/VDE-2022-060/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Compact Controller CC100 (751-9301)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "FW22 Patch 1"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Edge Controller (752-8303/8000-002)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW18",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "FW22 Patch 1"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "PFC100 (750-81xx/xxx-xxx)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "FW22 Patch 1"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "PFC200 (750-82xx/xxx-xxx)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "FW22 Patch 1"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Touch Panel 600 Advanced Line (762-5xxx)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "FW22 Patch 1"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Touch Panel 600 Marine Line (762-6xxx)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "FW22 Patch 1"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Touch Panel 600 Standard Line (762-4xxx)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "FW22 Patch 1"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Ryan Pickren of Georgia Institute of Technologys Cyber-Physical Security Lab"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "The configuration backend of the web-based management is vulnerable to reflected XSS (Cross-Site Scripting) attacks that targets the users browser. This leads to a limited impact of confidentiality and integrity but no impact of availability."
                }
              ],
              "value": "The configuration backend of the web-based management is vulnerable to reflected XSS (Cross-Site Scripting) attacks that targets the users browser. This leads to a limited impact of confidentiality and integrity but no impact of availability."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-63",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-63 Cross-Site Scripting (XSS)"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 6.1,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-79",
                  "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-02-27T14:36:03.411Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://cert.vde.com/en/advisories/VDE-2022-060/"
            }
          ],
          "source": {
            "defect": [
              "CERT@VDE#64160"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "WAGO: Reflective Cross-Site Scripting",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2022-45137",
        "datePublished": "2023-02-27T14:36:03.411Z",
        "dateReserved": "2022-11-10T09:46:59.079Z",
        "dateUpdated": "2024-08-03T14:09:56.545Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-22511 (GCVE-0-2022-22511)

    Vulnerability from nvd – Published: 2022-03-09 19:38 – Updated: 2024-09-17 00:16
    VLAI
    Title
    WAGO PLCs WBM vulnerable to reflected XSS
    Summary
    Various configuration pages of the device are vulnerable to reflected XSS (Cross-Site Scripting) attacks. An authorized attacker with user privileges may use this to gain access to confidential information on a PC that connects to the WBM after it has been compromised.
    CWE
    • CWE-79 - Cross-site Scripting (XSS)
    Assigner
    References
    Date Public
    2022-03-09 00:00
    Credits
    These vulnerabilities were reported to WAGO by: Mohamed Magdy Abumuslim, coordination done by CERT@VDE.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T03:14:55.300Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://cert.vde.com/en/advisories/VDE-2022-004/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Compact Controller CC100 (751-9301)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "Edge Controller (752-8303/8000-002)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "Series PFC100 (750-81xx/xxx-xxx)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "Series PFC200 (750-82xx/xxx-xxx)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "Series Touch Panel 600 Advanced Line (762-5xxx)",
              "vendor": "WAGO",
              "versions": [
                {
                  "status": "affected",
                  "version": "FW16 FW22"
                }
              ]
            },
            {
              "product": "Series Touch Panel 600 Marine Line (762-6xxx)",
              "vendor": "WAGO",
              "versions": [
                {
                  "status": "affected",
                  "version": "FW16 FW22"
                }
              ]
            },
            {
              "product": "Series Touch Panel 600 Standard Line (762-4xxx)",
              "vendor": "WAGO",
              "versions": [
                {
                  "status": "affected",
                  "version": "FW16 FW22"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "These vulnerabilities were reported to WAGO by: Mohamed Magdy Abumuslim, coordination done by CERT@VDE."
            }
          ],
          "datePublic": "2022-03-09T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Various configuration pages of the device are vulnerable to reflected XSS (Cross-Site Scripting) attacks. An authorized attacker with user privileges may use this to gain access to confidential information on a PC that connects to the WBM after it has been compromised."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 5.4,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "LOW",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-79",
                  "description": "CWE-79 Cross-site Scripting (XSS)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-03-09T19:38:43.000Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://cert.vde.com/en/advisories/VDE-2022-004/"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "value": "Install FW \u003e=FW22 (FW22 planned for end of Q2/22)"
            }
          ],
          "source": {
            "advisory": "VDE-2022-004",
            "defect": [
              "CERT@VDE#64068"
            ],
            "discovery": "EXTERNAL"
          },
          "title": "WAGO PLCs WBM vulnerable to reflected XSS",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "info@cert.vde.com",
              "DATE_PUBLIC": "2022-03-09T07:00:00.000Z",
              "ID": "CVE-2022-22511",
              "STATE": "PUBLIC",
              "TITLE": "WAGO PLCs WBM vulnerable to reflected XSS"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Compact Controller CC100 (751-9301)",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "FW16",
                                "version_value": "FW22"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "Edge Controller (752-8303/8000-002)",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "FW16",
                                "version_value": "FW22"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "Series PFC100 (750-81xx/xxx-xxx)",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "FW16",
                                "version_value": "FW22"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "Series PFC200 (750-82xx/xxx-xxx)",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "FW16",
                                "version_value": "FW22"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "Series Touch Panel 600 Advanced Line (762-5xxx)",
                          "version": {
                            "version_data": [
                              {
                                "version_name": "FW16",
                                "version_value": "FW22"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "Series Touch Panel 600 Marine Line (762-6xxx)",
                          "version": {
                            "version_data": [
                              {
                                "version_name": "FW16",
                                "version_value": "FW22"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "Series Touch Panel 600 Standard Line (762-4xxx)",
                          "version": {
                            "version_data": [
                              {
                                "version_name": "FW16",
                                "version_value": "FW22"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "WAGO"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "These vulnerabilities were reported to WAGO by: Mohamed Magdy Abumuslim, coordination done by CERT@VDE."
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Various configuration pages of the device are vulnerable to reflected XSS (Cross-Site Scripting) attacks. An authorized attacker with user privileges may use this to gain access to confidential information on a PC that connects to the WBM after it has been compromised."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 5.4,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "LOW",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-79 Cross-site Scripting (XSS)"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://cert.vde.com/en/advisories/VDE-2022-004/",
                  "refsource": "CONFIRM",
                  "url": "https://cert.vde.com/en/advisories/VDE-2022-004/"
                }
              ]
            },
            "solution": [
              {
                "lang": "en",
                "value": "Install FW \u003e=FW22 (FW22 planned for end of Q2/22)"
              }
            ],
            "source": {
              "advisory": "VDE-2022-004",
              "defect": [
                "CERT@VDE#64068"
              ],
              "discovery": "EXTERNAL"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2022-22511",
        "datePublished": "2022-03-09T19:38:43.516Z",
        "dateReserved": "2022-01-03T00:00:00.000Z",
        "dateUpdated": "2024-09-17T00:16:00.059Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-45140 (GCVE-0-2022-45140)

    Vulnerability from cvelistv5 – Published: 2023-02-27 14:36 – Updated: 2025-03-10 17:46
    VLAI
    Title
    WAGO: Missing Authentication for Critical Function
    Summary
    The configuration backend allows an unauthenticated user to write arbitrary data with root privileges to the storage, which could lead to unauthenticated remote code execution and full system compromise.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-306 - Missing Authentication for Critical Function
    Assigner
    References
    Impacted products
    Vendor Product Version
    WAGO Compact Controller CC100 (751-9301) Affected: FW16 , < FW22 (custom)
    Unaffected: FW22 Patch 1
    Affected: FW23
    Create a notification for this product.
    WAGO Edge Controller (752-8303/8000-002) Affected: FW16 , < FW22 (custom)
    Unaffected: FW22 Patch 1
    Affected: FW23
    Create a notification for this product.
    WAGO PFC100 (750-81xx/xxx-xxx) Affected: FW16 , < FW22 (custom)
    Unaffected: FW22 Patch 1
    Affected: FW23
    Create a notification for this product.
    WAGO PFC200 (750-82xx/xxx-xxx) Affected: FW16 , < FW22 (custom)
    Unaffected: FW22 Patch 1
    Affected: FW23
    Create a notification for this product.
    WAGO Touch Panel 600 Advanced Line (762-5xxx) Affected: FW16 , < FW22 (custom)
    Unaffected: FW22 Patch 1
    Affected: FW23
    Create a notification for this product.
    WAGO Touch Panel 600 Marine Line (762-6xxx) Affected: FW16 , < FW22 (custom)
    Unaffected: FW22 Patch 1
    Affected: FW23
    Create a notification for this product.
    WAGO Touch Panel 600 Standard Line (762-4xxx) Affected: FW16 , < FW22 (custom)
    Unaffected: FW22 Patch 1
    Affected: FW23
    Create a notification for this product.
    Credits
    Ryan Pickren of Georgia Institute of Technologys Cyber-Physical Security Lab
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T14:09:55.436Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert.vde.com/en/advisories/VDE-2022-060/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-45140",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-03-10T17:46:43.476712Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-03-10T17:46:52.078Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Compact Controller CC100 (751-9301)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "FW22 Patch 1"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Edge Controller (752-8303/8000-002)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "FW22 Patch 1"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "PFC100 (750-81xx/xxx-xxx)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "FW22 Patch 1"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "PFC200 (750-82xx/xxx-xxx)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "FW22 Patch 1"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Touch Panel 600 Advanced Line (762-5xxx)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "FW22 Patch 1"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Touch Panel 600 Marine Line (762-6xxx)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "FW22 Patch 1"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Touch Panel 600 Standard Line (762-4xxx)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "FW22 Patch 1"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Ryan Pickren of Georgia Institute of Technologys Cyber-Physical Security Lab"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "The configuration backend allows an unauthenticated user to write arbitrary data with root privileges to the storage, which could lead to unauthenticated remote code execution and full system compromise."
                }
              ],
              "value": "The configuration backend allows an unauthenticated user to write arbitrary data with root privileges to the storage, which could lead to unauthenticated remote code execution and full system compromise."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-115",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-115 Authentication Bypass"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-306",
                  "description": "CWE-306 Missing Authentication for Critical Function",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-02-27T14:36:39.448Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://cert.vde.com/en/advisories/VDE-2022-060/"
            }
          ],
          "source": {
            "defect": [
              "CERT@VDE#64160"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "WAGO: Missing Authentication for Critical Function ",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2022-45140",
        "datePublished": "2023-02-27T14:36:39.448Z",
        "dateReserved": "2022-11-10T09:46:59.080Z",
        "dateUpdated": "2025-03-10T17:46:52.078Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-45139 (GCVE-0-2022-45139)

    Vulnerability from cvelistv5 – Published: 2023-02-27 14:36 – Updated: 2025-03-10 17:46
    VLAI
    Title
    WAGO: Origin validation error through CORS misconfiguration
    Summary
    A CORS Misconfiguration in the web-based management allows a malicious third party webserver to misuse all basic information pages on the webserver. In combination with CVE-2022-45138 this could lead to disclosure of device information like CPU diagnostics. As there is just a limited amount of information readable the impact only affects a small subset of confidentiality.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-346 - Origin Validation Error
    Assigner
    References
    Impacted products
    Vendor Product Version
    WAGO Compact Controller CC100 (751-9301) Affected: FW16 , < FW22 (custom)
    Unaffected: FW22 Patch 1
    Affected: FW23
    Create a notification for this product.
    WAGO Edge Controller (752-8303/8000-002) Affected: FW18 , < FW22 (custom)
    Unaffected: FW22 Patch 1
    Affected: FW23
    Create a notification for this product.
    WAGO PFC100 (750-81xx/xxx-xxx) Affected: FW16 , < FW22 (custom)
    Unaffected: FW22 Patch 1
    Affected: FW23
    Create a notification for this product.
    WAGO PFC200 (750-82xx/xxx-xxx) Affected: FW16 , < FW22 (custom)
    Unaffected: FW22 Patch 1
    Affected: FW23
    Create a notification for this product.
    WAGO Touch Panel 600 Advanced Line (762-5xxx) Affected: FW16 , < FW22 (custom)
    Unaffected: FW22 Patch 1
    Affected: FW23
    Create a notification for this product.
    WAGO Touch Panel 600 Marine Line (762-6xxx) Affected: FW16 , < FW22 (custom)
    Unaffected: FW22 Patch 1
    Affected: FW23
    Create a notification for this product.
    WAGO Touch Panel 600 Standard Line (762-4xxx) Affected: FW16 , < FW22 (custom)
    Unaffected: FW22 Patch 1
    Affected: FW23
    Create a notification for this product.
    Credits
    Ryan Pickren of Georgia Institute of Technologys Cyber-Physical Security Lab
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T14:09:55.406Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert.vde.com/en/advisories/VDE-2022-060/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-45139",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-03-10T17:45:54.261351Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-03-10T17:46:16.888Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Compact Controller CC100 (751-9301)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "FW22 Patch 1"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Edge Controller (752-8303/8000-002)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW18",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "FW22 Patch 1"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "PFC100 (750-81xx/xxx-xxx)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "FW22 Patch 1"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "PFC200 (750-82xx/xxx-xxx)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "FW22 Patch 1"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Touch Panel 600 Advanced Line (762-5xxx)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "FW22 Patch 1"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Touch Panel 600 Marine Line (762-6xxx)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "FW22 Patch 1"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Touch Panel 600 Standard Line (762-4xxx)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "FW22 Patch 1"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Ryan Pickren of Georgia Institute of Technologys Cyber-Physical Security Lab"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "A CORS Misconfiguration in the web-based management allows a malicious third party webserver to misuse all basic information pages on the webserver. In combination with CVE-2022-45138 this could lead to disclosure of device information like CPU diagnostics. As there is just a limited amount of information readable the impact only affects a small subset of confidentiality."
                }
              ],
              "value": "A CORS Misconfiguration in the web-based management allows a malicious third party webserver to misuse all basic information pages on the webserver. In combination with CVE-2022-45138 this could lead to disclosure of device information like CPU diagnostics. As there is just a limited amount of information readable the impact only affects a small subset of confidentiality."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-554",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-554 Functionality Bypass"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-346",
                  "description": "CWE-346 Origin Validation Error",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-02-27T14:36:32.016Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://cert.vde.com/en/advisories/VDE-2022-060/"
            }
          ],
          "source": {
            "defect": [
              "CERT@VDE#64160"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "WAGO: Origin validation error through CORS misconfiguration",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2022-45139",
        "datePublished": "2023-02-27T14:36:32.016Z",
        "dateReserved": "2022-11-10T09:46:59.080Z",
        "dateUpdated": "2025-03-10T17:46:16.888Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-45138 (GCVE-0-2022-45138)

    Vulnerability from cvelistv5 – Published: 2023-02-27 14:36 – Updated: 2025-03-10 17:20
    VLAI
    Title
    WAGO: Missing Authentication for Critical Function
    Summary
    The configuration backend of the web-based management can be used by unauthenticated users, although only authenticated users should be able to use the API. The vulnerability allows an unauthenticated attacker to read and set several device parameters that can lead to full compromise of the device.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-306 - Missing Authentication for Critical Function
    Assigner
    References
    Impacted products
    Vendor Product Version
    WAGO Compact Controller CC100 (751-9301) Affected: FW16 , < FW22 (custom)
    Unaffected: FW22 Patch 1
    Affected: FW23
    Create a notification for this product.
    WAGO Edge Controller (752-8303/8000-002) Affected: FW18 , < FW22 (custom)
    Unaffected: FW22 Patch 1
    Affected: FW23
    Create a notification for this product.
    WAGO PFC100 (750-81xx/xxx-xxx) Affected: FW16 , < FW22 (custom)
    Unaffected: FW22 Patch 1
    Affected: FW23
    Create a notification for this product.
    WAGO PFC200 (750-82xx/xxx-xxx) Affected: FW16 , < FW22 (custom)
    Unaffected: FW22 Patch 1
    Affected: FW23
    Create a notification for this product.
    WAGO Touch Panel 600 Advanced Line (762-5xxx) Affected: FW16 , < FW22 (custom)
    Unaffected: FW22 Patch 1
    Affected: FW23
    Create a notification for this product.
    WAGO Touch Panel 600 Marine Line (762-6xxx) Affected: FW16 , < FW22 (custom)
    Unaffected: FW22 Patch 1
    Affected: FW23
    Create a notification for this product.
    WAGO Touch Panel 600 Standard Line (762-4xxx) Affected: FW16 , < FW22 (custom)
    Unaffected: FW22 Patch 1
    Affected: FW23
    Create a notification for this product.
    Credits
    Ryan Pickren of Georgia Institute of Technologys Cyber-Physical Security Lab
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T14:09:55.415Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert.vde.com/en/advisories/VDE-2022-060/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-45138",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-03-10T17:20:33.215201Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-03-10T17:20:50.798Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Compact Controller CC100 (751-9301)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "FW22 Patch 1"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Edge Controller (752-8303/8000-002)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW18",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "FW22 Patch 1"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "PFC100 (750-81xx/xxx-xxx)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "FW22 Patch 1"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "PFC200 (750-82xx/xxx-xxx)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "FW22 Patch 1"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Touch Panel 600 Advanced Line (762-5xxx)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "FW22 Patch 1"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Touch Panel 600 Marine Line (762-6xxx)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "FW22 Patch 1"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Touch Panel 600 Standard Line (762-4xxx)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "FW22 Patch 1"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Ryan Pickren of Georgia Institute of Technologys Cyber-Physical Security Lab"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "The configuration backend of the web-based management can be used by unauthenticated users, although only authenticated users should be able to use the API. The vulnerability allows an unauthenticated attacker to read and set several device parameters that can lead to full compromise of the device."
                }
              ],
              "value": "The configuration backend of the web-based management can be used by unauthenticated users, although only authenticated users should be able to use the API. The vulnerability allows an unauthenticated attacker to read and set several device parameters that can lead to full compromise of the device."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-115",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-115 Authentication Bypass"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-306",
                  "description": "CWE-306 Missing Authentication for Critical Function",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-02-27T14:36:20.474Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://cert.vde.com/en/advisories/VDE-2022-060/"
            }
          ],
          "source": {
            "defect": [
              "CERT@VDE#64160"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "WAGO: Missing Authentication for Critical Function",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2022-45138",
        "datePublished": "2023-02-27T14:36:20.474Z",
        "dateReserved": "2022-11-10T09:46:59.079Z",
        "dateUpdated": "2025-03-10T17:20:50.798Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-45137 (GCVE-0-2022-45137)

    Vulnerability from cvelistv5 – Published: 2023-02-27 14:36 – Updated: 2024-08-03 14:09
    VLAI
    Title
    WAGO: Reflective Cross-Site Scripting
    Summary
    The configuration backend of the web-based management is vulnerable to reflected XSS (Cross-Site Scripting) attacks that targets the users browser. This leads to a limited impact of confidentiality and integrity but no impact of availability.
    CWE
    • CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
    Assigner
    References
    Impacted products
    Vendor Product Version
    WAGO Compact Controller CC100 (751-9301) Affected: FW16 , < FW22 (custom)
    Unaffected: FW22 Patch 1
    Affected: FW23
    Create a notification for this product.
    WAGO Edge Controller (752-8303/8000-002) Affected: FW18 , < FW22 (custom)
    Unaffected: FW22 Patch 1
    Affected: FW23
    Create a notification for this product.
    WAGO PFC100 (750-81xx/xxx-xxx) Affected: FW16 , < FW22 (custom)
    Unaffected: FW22 Patch 1
    Affected: FW23
    Create a notification for this product.
    WAGO PFC200 (750-82xx/xxx-xxx) Affected: FW16 , < FW22 (custom)
    Unaffected: FW22 Patch 1
    Affected: FW23
    Create a notification for this product.
    WAGO Touch Panel 600 Advanced Line (762-5xxx) Affected: FW16 , < FW22 (custom)
    Unaffected: FW22 Patch 1
    Affected: FW23
    Create a notification for this product.
    WAGO Touch Panel 600 Marine Line (762-6xxx) Affected: FW16 , < FW22 (custom)
    Unaffected: FW22 Patch 1
    Affected: FW23
    Create a notification for this product.
    WAGO Touch Panel 600 Standard Line (762-4xxx) Affected: FW16 , < FW22 (custom)
    Unaffected: FW22 Patch 1
    Affected: FW23
    Create a notification for this product.
    Credits
    Ryan Pickren of Georgia Institute of Technologys Cyber-Physical Security Lab
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T14:09:56.545Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert.vde.com/en/advisories/VDE-2022-060/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Compact Controller CC100 (751-9301)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "FW22 Patch 1"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Edge Controller (752-8303/8000-002)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW18",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "FW22 Patch 1"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "PFC100 (750-81xx/xxx-xxx)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "FW22 Patch 1"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "PFC200 (750-82xx/xxx-xxx)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "FW22 Patch 1"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Touch Panel 600 Advanced Line (762-5xxx)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "FW22 Patch 1"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Touch Panel 600 Marine Line (762-6xxx)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "FW22 Patch 1"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Touch Panel 600 Standard Line (762-4xxx)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                },
                {
                  "status": "unaffected",
                  "version": "FW22 Patch 1"
                },
                {
                  "status": "affected",
                  "version": "FW23"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Ryan Pickren of Georgia Institute of Technologys Cyber-Physical Security Lab"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "The configuration backend of the web-based management is vulnerable to reflected XSS (Cross-Site Scripting) attacks that targets the users browser. This leads to a limited impact of confidentiality and integrity but no impact of availability."
                }
              ],
              "value": "The configuration backend of the web-based management is vulnerable to reflected XSS (Cross-Site Scripting) attacks that targets the users browser. This leads to a limited impact of confidentiality and integrity but no impact of availability."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-63",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-63 Cross-Site Scripting (XSS)"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 6.1,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-79",
                  "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-02-27T14:36:03.411Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://cert.vde.com/en/advisories/VDE-2022-060/"
            }
          ],
          "source": {
            "defect": [
              "CERT@VDE#64160"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "WAGO: Reflective Cross-Site Scripting",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2022-45137",
        "datePublished": "2023-02-27T14:36:03.411Z",
        "dateReserved": "2022-11-10T09:46:59.079Z",
        "dateUpdated": "2024-08-03T14:09:56.545Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-22511 (GCVE-0-2022-22511)

    Vulnerability from cvelistv5 – Published: 2022-03-09 19:38 – Updated: 2024-09-17 00:16
    VLAI
    Title
    WAGO PLCs WBM vulnerable to reflected XSS
    Summary
    Various configuration pages of the device are vulnerable to reflected XSS (Cross-Site Scripting) attacks. An authorized attacker with user privileges may use this to gain access to confidential information on a PC that connects to the WBM after it has been compromised.
    CWE
    • CWE-79 - Cross-site Scripting (XSS)
    Assigner
    References
    Date Public
    2022-03-09 00:00
    Credits
    These vulnerabilities were reported to WAGO by: Mohamed Magdy Abumuslim, coordination done by CERT@VDE.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T03:14:55.300Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://cert.vde.com/en/advisories/VDE-2022-004/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Compact Controller CC100 (751-9301)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "Edge Controller (752-8303/8000-002)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "Series PFC100 (750-81xx/xxx-xxx)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "Series PFC200 (750-82xx/xxx-xxx)",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThan": "FW22",
                  "status": "affected",
                  "version": "FW16",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "Series Touch Panel 600 Advanced Line (762-5xxx)",
              "vendor": "WAGO",
              "versions": [
                {
                  "status": "affected",
                  "version": "FW16 FW22"
                }
              ]
            },
            {
              "product": "Series Touch Panel 600 Marine Line (762-6xxx)",
              "vendor": "WAGO",
              "versions": [
                {
                  "status": "affected",
                  "version": "FW16 FW22"
                }
              ]
            },
            {
              "product": "Series Touch Panel 600 Standard Line (762-4xxx)",
              "vendor": "WAGO",
              "versions": [
                {
                  "status": "affected",
                  "version": "FW16 FW22"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "These vulnerabilities were reported to WAGO by: Mohamed Magdy Abumuslim, coordination done by CERT@VDE."
            }
          ],
          "datePublic": "2022-03-09T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Various configuration pages of the device are vulnerable to reflected XSS (Cross-Site Scripting) attacks. An authorized attacker with user privileges may use this to gain access to confidential information on a PC that connects to the WBM after it has been compromised."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 5.4,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "LOW",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-79",
                  "description": "CWE-79 Cross-site Scripting (XSS)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-03-09T19:38:43.000Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://cert.vde.com/en/advisories/VDE-2022-004/"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "value": "Install FW \u003e=FW22 (FW22 planned for end of Q2/22)"
            }
          ],
          "source": {
            "advisory": "VDE-2022-004",
            "defect": [
              "CERT@VDE#64068"
            ],
            "discovery": "EXTERNAL"
          },
          "title": "WAGO PLCs WBM vulnerable to reflected XSS",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "info@cert.vde.com",
              "DATE_PUBLIC": "2022-03-09T07:00:00.000Z",
              "ID": "CVE-2022-22511",
              "STATE": "PUBLIC",
              "TITLE": "WAGO PLCs WBM vulnerable to reflected XSS"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Compact Controller CC100 (751-9301)",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "FW16",
                                "version_value": "FW22"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "Edge Controller (752-8303/8000-002)",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "FW16",
                                "version_value": "FW22"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "Series PFC100 (750-81xx/xxx-xxx)",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "FW16",
                                "version_value": "FW22"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "Series PFC200 (750-82xx/xxx-xxx)",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "FW16",
                                "version_value": "FW22"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "Series Touch Panel 600 Advanced Line (762-5xxx)",
                          "version": {
                            "version_data": [
                              {
                                "version_name": "FW16",
                                "version_value": "FW22"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "Series Touch Panel 600 Marine Line (762-6xxx)",
                          "version": {
                            "version_data": [
                              {
                                "version_name": "FW16",
                                "version_value": "FW22"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "Series Touch Panel 600 Standard Line (762-4xxx)",
                          "version": {
                            "version_data": [
                              {
                                "version_name": "FW16",
                                "version_value": "FW22"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "WAGO"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "These vulnerabilities were reported to WAGO by: Mohamed Magdy Abumuslim, coordination done by CERT@VDE."
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Various configuration pages of the device are vulnerable to reflected XSS (Cross-Site Scripting) attacks. An authorized attacker with user privileges may use this to gain access to confidential information on a PC that connects to the WBM after it has been compromised."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 5.4,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "LOW",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-79 Cross-site Scripting (XSS)"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://cert.vde.com/en/advisories/VDE-2022-004/",
                  "refsource": "CONFIRM",
                  "url": "https://cert.vde.com/en/advisories/VDE-2022-004/"
                }
              ]
            },
            "solution": [
              {
                "lang": "en",
                "value": "Install FW \u003e=FW22 (FW22 planned for end of Q2/22)"
              }
            ],
            "source": {
              "advisory": "VDE-2022-004",
              "defect": [
                "CERT@VDE#64068"
              ],
              "discovery": "EXTERNAL"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2022-22511",
        "datePublished": "2022-03-09T19:38:43.516Z",
        "dateReserved": "2022-01-03T00:00:00.000Z",
        "dateUpdated": "2024-09-17T00:16:00.059Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }