Search
Find a vulnerability
Search criteria
18 vulnerabilities found for CloudVision CUE by Arista Networks
CVE-2026-102161 (GCVE-0-2026-102161)
Vulnerability from nvd – Published: 2026-10-06 19:39 – Updated: 2026-10-06 20:04
VLAI
EPSS
VEX
Title
Security Advisory 0190
Summary
An unauthenticated attacker located on an adjacent private network (or any attacker routed through a reverse proxy/load balancer that forwards client headers) can forge their source IP address and gain administrative session privileges on the CV-CUE backend.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-10-06 20:04 UTC
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.arista.com/en/support/advisories-noti… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Arista Networks | CloudVision CUE |
Affected:
2021.2.0 , ≤ 2026.2.0
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-102161",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-10-06T20:04:00.722473Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-10-06T20:04:10.245Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"platforms": [
"CloudVision CUE on-premises, virtual appliance or physical appliance"
],
"product": "CloudVision CUE",
"vendor": "Arista Networks",
"versions": [
{
"lessThanOrEqual": "2026.2.0",
"status": "affected",
"version": "2021.2.0",
"versionType": "custom"
}
]
}
],
"configurations": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eTo be vulnerable, CV-CUE backend (wifimanager) must be enabled and running. To inspect the status of wifimanager:\u003c/p\u003e\u003cpre\u003e[root@]# cvpi status wifimanager\nExecuting command. This may take some time...\nCompleted 1/1 discovered actions\nprimary components total:1 running:1 disabled:0\u003c/pre\u003e"
}
],
"value": "To be vulnerable, CV-CUE backend (wifimanager) must be enabled and running. To inspect the status of wifimanager:\n\n[root@]# cvpi status wifimanager\nExecuting command. This may take some time...\nCompleted 1/1 discovered actions\nprimary components total:1 running:1 disabled:0"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eAn unauthenticated attacker located on an adjacent private network (or any attacker routed through a reverse proxy/load balancer that forwards client headers) can forge their source IP address and gain administrative session privileges on the CV-CUE backend.\u003c/p\u003e"
}
],
"value": "An unauthenticated attacker located on an adjacent private network (or any attacker routed through a reverse proxy/load balancer that forwards client headers) can forge their source IP address and gain administrative session privileges on the CV-CUE backend."
}
],
"impacts": [
{
"capecId": "CAPEC-194",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-194 Fake the Source of Data"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-798",
"description": "CWE-798 Use of Hard-coded Credentials",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-290",
"description": "CWE-290 Authentication Bypass by Spoofing",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-10-06T19:39:54.646Z",
"orgId": "c8b34d1a-69ae-45c3-88fe-f3b3d44f39b7",
"shortName": "Arista"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.arista.com/en/support/advisories-notices/security-advisory/24806-security-advisory-0190"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eCVE-2026-102161 has been fixed in the following releases:\u003c/p\u003e\u003cul\u003e\u003cli\u003e2026.2.1 and later releases\u003c/li\u003e\u003c/ul\u003e"
}
],
"value": "CVE-2026-102161 has been fixed in the following releases:\n- 2026.2.1 and later releases"
}
],
"source": {
"advisory": "Security Advisory 0190",
"defects": [
"BUG 1728203"
],
"discovery": "INTERNAL"
},
"title": "Security Advisory 0190",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eThere is no mitigation or workaround available for this issue.\u003c/p\u003e"
}
],
"value": "There is no mitigation or workaround available for this issue."
}
]
}
},
"cveMetadata": {
"assignerOrgId": "c8b34d1a-69ae-45c3-88fe-f3b3d44f39b7",
"assignerShortName": "Arista",
"cveId": "CVE-2026-102161",
"datePublished": "2026-10-06T19:39:54.646Z",
"dateReserved": "2026-09-28T17:41:09.358Z",
"dateUpdated": "2026-10-06T20:04:10.245Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-102160 (GCVE-0-2026-102160)
Vulnerability from nvd – Published: 2026-10-06 19:39 – Updated: 2026-10-06 20:03
VLAI
EPSS
VEX
Title
Security Advisory 0190
Summary
An operating system (OS) command injection vulnerability in CloudVision CUE backup management may allow an authenticated Super User to submit a crafted backup request and execute arbitrary commands with the privileges of the affected service.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-10-06 20:03 UTC
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.arista.com/en/support/advisories-noti… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Arista Networks | CloudVision CUE |
Affected:
2021.2.0 , ≤ 2026.2.0
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-102160",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-10-06T20:03:34.193659Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-10-06T20:03:43.702Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"platforms": [
"CloudVision CUE on-premises, virtual appliance or physical appliance"
],
"product": "CloudVision CUE",
"vendor": "Arista Networks",
"versions": [
{
"lessThanOrEqual": "2026.2.0",
"status": "affected",
"version": "2021.2.0",
"versionType": "custom"
}
]
}
],
"configurations": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eTo be vulnerable, CV-CUE backend (wifimanager) must be enabled and running. To inspect the status of wifimanager:\u003c/p\u003e\u003cpre\u003e[root@]# cvpi status wifimanager\nExecuting command. This may take some time...\nCompleted 1/1 discovered actions\nprimary components total:1 running:1 disabled:0\u003c/pre\u003e"
}
],
"value": "To be vulnerable, CV-CUE backend (wifimanager) must be enabled and running. To inspect the status of wifimanager:\n\n[root@]# cvpi status wifimanager\nExecuting command. This may take some time...\nCompleted 1/1 discovered actions\nprimary components total:1 running:1 disabled:0"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eAn operating system (OS) command injection vulnerability in CloudVision CUE backup management may allow an authenticated Super User to submit a crafted backup request and execute arbitrary commands with the privileges of the affected service.\u003c/p\u003e"
}
],
"value": "An operating system (OS) command injection vulnerability in CloudVision CUE backup management may allow an authenticated Super User to submit a crafted backup request and execute arbitrary commands with the privileges of the affected service."
}
],
"impacts": [
{
"capecId": "CAPEC-88",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-88 OS Command Injection"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.2,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"baseScore": 8.6,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-10-06T19:39:54.096Z",
"orgId": "c8b34d1a-69ae-45c3-88fe-f3b3d44f39b7",
"shortName": "Arista"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.arista.com/en/support/advisories-notices/security-advisory/24806-security-advisory-0190"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eCVE-2026-102160 has been fixed in the following releases:\u003c/p\u003e\u003cul\u003e\u003cli\u003e2026.2.1 and later releases\u003c/li\u003e\u003c/ul\u003e"
}
],
"value": "CVE-2026-102160 has been fixed in the following releases:\n- 2026.2.1 and later releases"
}
],
"source": {
"advisory": "Security Advisory 0190",
"defects": [
"BUG 1728182"
],
"discovery": "INTERNAL"
},
"title": "Security Advisory 0190",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eThere is no mitigation or workaround available for this issue.\u003c/p\u003e"
}
],
"value": "There is no mitigation or workaround available for this issue."
}
]
}
},
"cveMetadata": {
"assignerOrgId": "c8b34d1a-69ae-45c3-88fe-f3b3d44f39b7",
"assignerShortName": "Arista",
"cveId": "CVE-2026-102160",
"datePublished": "2026-10-06T19:39:54.096Z",
"dateReserved": "2026-09-28T17:41:09.358Z",
"dateUpdated": "2026-10-06T20:03:43.702Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-102159 (GCVE-0-2026-102159)
Vulnerability from nvd – Published: 2026-10-06 19:39 – Updated: 2026-10-06 20:03
VLAI
EPSS
VEX
Title
Security Advisory 0190
Summary
An access-control flaw in the CV-CUE backend may allow an unauthenticated network attacker to access functionality intended only for internal services. Successful exploitation may expose sensitive location information or disrupt affected services.
Severity
9.8 (Critical)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-10-06 20:03 UTC
CWE
- CWE-306 - Missing Authentication for Critical Function
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.arista.com/en/support/advisories-noti… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Arista Networks | CloudVision CUE |
Affected:
2022.3.0 , ≤ 2026.2.0
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-102159",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-10-06T20:03:00.815750Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-10-06T20:03:15.078Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"platforms": [
"CloudVision CUE on-premises, virtual appliance or physical appliance"
],
"product": "CloudVision CUE",
"vendor": "Arista Networks",
"versions": [
{
"lessThanOrEqual": "2026.2.0",
"status": "affected",
"version": "2022.3.0",
"versionType": "custom"
}
]
}
],
"configurations": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eTo be vulnerable, CV-CUE backend (wifimanager) must be enabled and running. To inspect the status of wifimanager:\u003c/p\u003e\u003cpre\u003e[root@]# cvpi status wifimanager\nExecuting command. This may take some time...\nCompleted 1/1 discovered actions\nprimary components total:1 running:1 disabled:0\u003c/pre\u003e"
}
],
"value": "To be vulnerable, CV-CUE backend (wifimanager) must be enabled and running. To inspect the status of wifimanager:\n\n[root@]# cvpi status wifimanager\nExecuting command. This may take some time...\nCompleted 1/1 discovered actions\nprimary components total:1 running:1 disabled:0"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eAn access-control flaw in the CV-CUE backend may allow an unauthenticated network attacker to access functionality intended only for internal services. Successful exploitation may expose sensitive location information or disrupt affected services.\u003c/p\u003e"
}
],
"value": "An access-control flaw in the CV-CUE backend may allow an unauthenticated network attacker to access functionality intended only for internal services. Successful exploitation may expose sensitive location information or disrupt affected services."
}
],
"impacts": [
{
"capecId": "CAPEC-115",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-115 Authentication Bypass"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"baseScore": 9.3,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306 Missing Authentication for Critical Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-10-06T19:39:53.582Z",
"orgId": "c8b34d1a-69ae-45c3-88fe-f3b3d44f39b7",
"shortName": "Arista"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.arista.com/en/support/advisories-notices/security-advisory/24806-security-advisory-0190"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eCVE-2026-102159 has been fixed in the following releases:\u003c/p\u003e\u003cul\u003e\u003cli\u003e2026.2.1 and later releases\u003c/li\u003e\u003c/ul\u003e"
}
],
"value": "CVE-2026-102159 has been fixed in the following releases:\n- 2026.2.1 and later releases"
}
],
"source": {
"advisory": "Security Advisory 0190",
"defects": [
"BUG 1732043"
],
"discovery": "INTERNAL"
},
"title": "Security Advisory 0190",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eThere is no mitigation or workaround available for this issue.\u003c/p\u003e"
}
],
"value": "There is no mitigation or workaround available for this issue."
}
]
}
},
"cveMetadata": {
"assignerOrgId": "c8b34d1a-69ae-45c3-88fe-f3b3d44f39b7",
"assignerShortName": "Arista",
"cveId": "CVE-2026-102159",
"datePublished": "2026-10-06T19:39:53.582Z",
"dateReserved": "2026-09-28T17:41:09.358Z",
"dateUpdated": "2026-10-06T20:03:15.078Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-102158 (GCVE-0-2026-102158)
Vulnerability from nvd – Published: 2026-10-06 19:39 – Updated: 2026-10-06 20:02
VLAI
EPSS
VEX
Title
Security Advisory 0190
Summary
Improper validation of selected CloudVision CUE application programming interface (API) request parameters may allow an authenticated network user to perform SQL injection against the backend impacting its availability.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-10-06 20:02 UTC
CWE
- CWE-74 - Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.arista.com/en/support/advisories-noti… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Arista Networks | CloudVision CUE |
Affected:
2022.2.0 , ≤ 2026.2.0
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-102158",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-10-06T20:02:19.932346Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-10-06T20:02:40.724Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"platforms": [
"CloudVision CUE on-premises, virtual appliance or physical appliance"
],
"product": "CloudVision CUE",
"vendor": "Arista Networks",
"versions": [
{
"lessThanOrEqual": "2026.2.0",
"status": "affected",
"version": "2022.2.0",
"versionType": "custom"
}
]
}
],
"configurations": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eTo be vulnerable, CV-CUE backend (wifimanager) must be enabled and running. To inspect the status of wifimanager:\u003c/p\u003e\u003cpre\u003e[root@]# cvpi status wifimanager\nExecuting command. This may take some time...\nCompleted 1/1 discovered actions\nprimary components total:1 running:1 disabled:0\u003c/pre\u003e"
}
],
"value": "To be vulnerable, CV-CUE backend (wifimanager) must be enabled and running. To inspect the status of wifimanager:\n\n[root@]# cvpi status wifimanager\nExecuting command. This may take some time...\nCompleted 1/1 discovered actions\nprimary components total:1 running:1 disabled:0"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eImproper validation of selected CloudVision CUE application programming interface (API) request parameters may allow an authenticated network user to perform SQL injection against the backend impacting its availability.\u003c/p\u003e"
}
],
"value": "Improper validation of selected CloudVision CUE application programming interface (API) request parameters may allow an authenticated network user to perform SQL injection against the backend impacting its availability."
}
],
"impacts": [
{
"capecId": "CAPEC-66",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-66 SQL Injection"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"baseScore": 7.1,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-74",
"description": "CWE-74 Improper Neutralization of Special Elements in Output Used by a Downstream Component (\u0027Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-10-06T19:39:53.096Z",
"orgId": "c8b34d1a-69ae-45c3-88fe-f3b3d44f39b7",
"shortName": "Arista"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.arista.com/en/support/advisories-notices/security-advisory/24806-security-advisory-0190"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eCVE-2026-102158 has been fixed in the following releases:\u003c/p\u003e\u003cul\u003e\u003cli\u003e2026.2.1 and later releases\u003c/li\u003e\u003c/ul\u003e"
}
],
"value": "CVE-2026-102158 has been fixed in the following releases:\n- 2026.2.1 and later releases"
}
],
"source": {
"advisory": "Security Advisory 0190",
"defects": [
"BUG 1731886"
],
"discovery": "INTERNAL"
},
"title": "Security Advisory 0190",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eThere is no mitigation or workaround available for this issue.\u003c/p\u003e"
}
],
"value": "There is no mitigation or workaround available for this issue."
}
]
}
},
"cveMetadata": {
"assignerOrgId": "c8b34d1a-69ae-45c3-88fe-f3b3d44f39b7",
"assignerShortName": "Arista",
"cveId": "CVE-2026-102158",
"datePublished": "2026-10-06T19:39:53.096Z",
"dateReserved": "2026-09-28T17:41:09.358Z",
"dateUpdated": "2026-10-06T20:02:40.724Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-102157 (GCVE-0-2026-102157)
Vulnerability from nvd – Published: 2026-10-06 19:39 – Updated: 2026-10-06 20:02
VLAI
EPSS
VEX
Title
Security Advisory 0190
Summary
An insecure direct object reference (IDOR) vulnerability in a CloudVision CUE file-serving interface may allow an authenticated network user, under specific attack conditions, to access another user's transient data.
Severity
5.9 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-10-06 20:01 UTC
CWE
- CWE-639 - Authorization Bypass Through User-Controlled Key
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.arista.com/en/support/advisories-noti… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Arista Networks | CloudVision CUE |
Affected:
2021.2.0 , ≤ 2026.2.0
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-102157",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-10-06T20:01:56.142507Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-10-06T20:02:04.283Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"platforms": [
"CloudVision CUE on-premises, virtual appliance or physical appliance"
],
"product": "CloudVision CUE",
"vendor": "Arista Networks",
"versions": [
{
"lessThanOrEqual": "2026.2.0",
"status": "affected",
"version": "2021.2.0",
"versionType": "custom"
}
]
}
],
"configurations": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eTo be vulnerable, CV-CUE backend (wifimanager) must be enabled and running. To inspect the status of wifimanager:\u003c/p\u003e\u003cpre\u003e[root@]# cvpi status wifimanager\nExecuting command. This may take some time...\nCompleted 1/1 discovered actions\nprimary components total:1 running:1 disabled:0\u003c/pre\u003e"
}
],
"value": "To be vulnerable, CV-CUE backend (wifimanager) must be enabled and running. To inspect the status of wifimanager:\n\n[root@]# cvpi status wifimanager\nExecuting command. This may take some time...\nCompleted 1/1 discovered actions\nprimary components total:1 running:1 disabled:0"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eAn insecure direct object reference (IDOR) vulnerability in a CloudVision CUE file-serving interface may allow an authenticated network user, under specific attack conditions, to access another user\u0027s transient data.\u003c/p\u003e"
}
],
"value": "An insecure direct object reference (IDOR) vulnerability in a CloudVision CUE file-serving interface may allow an authenticated network user, under specific attack conditions, to access another user\u0027s transient data."
}
],
"impacts": [
{
"capecId": "CAPEC-1",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-1 Accessing Functionality Not Properly Constrained by ACLs"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 5.9,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:N/A:L",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"baseScore": 6.8,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:L/UI:N/VC:H/VI:N/VA:L/SC:N/SI:N/SA:N",
"version": "4.0"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-639",
"description": "CWE-639 Authorization Bypass Through User-Controlled Key",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-10-06T19:39:52.569Z",
"orgId": "c8b34d1a-69ae-45c3-88fe-f3b3d44f39b7",
"shortName": "Arista"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.arista.com/en/support/advisories-notices/security-advisory/24806-security-advisory-0190"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eCVE-2026-102157 has been fixed in the following releases:\u003c/p\u003e\u003cul\u003e\u003cli\u003e2026.2.1 and later releases\u003c/li\u003e\u003c/ul\u003e"
}
],
"value": "CVE-2026-102157 has been fixed in the following releases:\n- 2026.2.1 and later releases"
}
],
"source": {
"advisory": "Security Advisory 0190",
"defects": [
"BUG 1728161"
],
"discovery": "INTERNAL"
},
"title": "Security Advisory 0190",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eThere is no mitigation or workaround available for this issue.\u003c/p\u003e"
}
],
"value": "There is no mitigation or workaround available for this issue."
}
]
}
},
"cveMetadata": {
"assignerOrgId": "c8b34d1a-69ae-45c3-88fe-f3b3d44f39b7",
"assignerShortName": "Arista",
"cveId": "CVE-2026-102157",
"datePublished": "2026-10-06T19:39:52.569Z",
"dateReserved": "2026-09-28T17:41:09.358Z",
"dateUpdated": "2026-10-06T20:02:04.283Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-102156 (GCVE-0-2026-102156)
Vulnerability from nvd – Published: 2026-10-06 19:40 – Updated: 2026-10-06 20:04
VLAI
EPSS
VEX
Title
Security Advisory 0191
Summary
Improper neutralization of Lightweight Directory Access Protocol (LDAP) authentication input may allow an unauthenticated network attacker, under high-complexity conditions, to inject queries against the configured directory service.
Severity
6.8 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-10-06 20:04 UTC
CWE
- CWE-74 - Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.arista.com/en/support/advisories-noti… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Arista Networks | CloudVision CUE |
Affected:
2021.2.0 , ≤ 2026.2.0
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-102156",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-10-06T20:04:24.354512Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-10-06T20:04:33.983Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"platforms": [
"CloudVision CUE on-premises, virtual appliance or physical appliance"
],
"product": "CloudVision CUE",
"vendor": "Arista Networks",
"versions": [
{
"lessThanOrEqual": "2026.2.0",
"status": "affected",
"version": "2021.2.0",
"versionType": "custom"
}
]
}
],
"configurations": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eBoth of the following conditions must be met:\u003c/p\u003e\u003col\u003e\u003cli\u003eCV-CUE backend (wifimanager) must be enabled and running.\u003c/li\u003e\u003cli\u003eLDAP authentication must be enabled for the User Accounts.\u003c/li\u003e\u003c/ol\u003e\u003cp\u003eTo inspect the status of wifimanager:\u003c/p\u003e\u003cpre\u003e[root@]# cvpi status wifimanager\nExecuting command. This may take some time...\nCompleted 1/1 discovered actions\nprimary components total:1 running:1 disabled:0\u003c/pre\u003e"
}
],
"value": "Both of the following conditions must be met:\n1. CV-CUE backend (wifimanager) must be enabled and running.\n2. LDAP authentication must be enabled for the User Accounts.\n\nTo inspect the status of wifimanager:\n[root@]# cvpi status wifimanager\nExecuting command. This may take some time...\nCompleted 1/1 discovered actions\nprimary components total:1 running:1 disabled:0"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eImproper neutralization of Lightweight Directory Access Protocol (LDAP) authentication input may allow an unauthenticated network attacker, under high-complexity conditions, to inject queries against the configured directory service.\u003c/p\u003e"
}
],
"value": "Improper neutralization of Lightweight Directory Access Protocol (LDAP) authentication input may allow an unauthenticated network attacker, under high-complexity conditions, to inject queries against the configured directory service."
}
],
"impacts": [
{
"capecId": "CAPEC-136",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-136 LDAP Injection"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 6.8,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"baseScore": 6.9,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:N/VC:N/VI:N/VA:N/SC:H/SI:N/SA:N",
"version": "4.0"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-74",
"description": "CWE-74 Improper Neutralization of Special Elements in Output Used by a Downstream Component (\u0027Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-10-06T19:40:28.369Z",
"orgId": "c8b34d1a-69ae-45c3-88fe-f3b3d44f39b7",
"shortName": "Arista"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.arista.com/en/support/advisories-notices/security-advisory/24807-security-advisory-0191"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eCVE-2026-102156 has been fixed in the following releases:\u003c/p\u003e\u003cul\u003e\u003cli\u003e2026.2.1 and later releases\u003c/li\u003e\u003c/ul\u003e"
}
],
"value": "CVE-2026-102156 has been fixed in the following releases:\n- 2026.2.1 and later releases"
}
],
"source": {
"advisory": "Security Advisory 0191",
"defects": [
"BUG 1731907"
],
"discovery": "INTERNAL"
},
"title": "Security Advisory 0191",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eThe recommended mitigation is to disable LDAP Authentication. Prior to implementing this, please ensure that an alternative authentication mechanism is properly configured and verified, as disabling LDAP authentication will prevent LDAP-dependent users from accessing or managing CV-CUE.\u003c/p\u003e"
}
],
"value": "The recommended mitigation is to disable LDAP Authentication. Prior to implementing this, please ensure that an alternative authentication mechanism is properly configured and verified, as disabling LDAP authentication will prevent LDAP-dependent users from accessing or managing CV-CUE."
}
]
}
},
"cveMetadata": {
"assignerOrgId": "c8b34d1a-69ae-45c3-88fe-f3b3d44f39b7",
"assignerShortName": "Arista",
"cveId": "CVE-2026-102156",
"datePublished": "2026-10-06T19:40:28.369Z",
"dateReserved": "2026-09-28T17:41:09.358Z",
"dateUpdated": "2026-10-06T20:04:33.983Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-102155 (GCVE-0-2026-102155)
Vulnerability from nvd – Published: 2026-10-06 19:39 – Updated: 2026-10-06 20:01
VLAI
EPSS
VEX
Title
Security Advisory 0190
Summary
An XML External Entity (XXE) injection vulnerability in the WiFi-server Spectralight application allows any authenticated user to send malicious requests, leading to arbitrary local file disclosure and partial denial of service.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-10-06 20:01 UTC
CWE
- CWE-611 - Improper Restriction of XML External Entity Reference
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.arista.com/en/support/advisories-noti… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Arista Networks | CloudVision CUE |
Affected:
2021.2.0 , ≤ 2026.2.0
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-102155",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-10-06T20:01:34.634435Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-10-06T20:01:43.823Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"platforms": [
"CloudVision CUE on-premises, virtual appliance or physical appliance"
],
"product": "CloudVision CUE",
"vendor": "Arista Networks",
"versions": [
{
"lessThanOrEqual": "2026.2.0",
"status": "affected",
"version": "2021.2.0",
"versionType": "custom"
}
]
}
],
"configurations": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eTo be vulnerable, CV-CUE backend (wifimanager) must be enabled and running. To inspect the status of wifimanager:\u003c/p\u003e\u003cpre\u003e[root@]# cvpi status wifimanager\nExecuting command. This may take some time...\nCompleted 1/1 discovered actions\nprimary components total:1 running:1 disabled:0\u003c/pre\u003e"
}
],
"value": "To be vulnerable, CV-CUE backend (wifimanager) must be enabled and running. To inspect the status of wifimanager:\n\n[root@]# cvpi status wifimanager\nExecuting command. This may take some time...\nCompleted 1/1 discovered actions\nprimary components total:1 running:1 disabled:0"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eAn XML External Entity (XXE) injection vulnerability in the WiFi-server Spectralight application allows any authenticated user to send malicious requests, leading to arbitrary local file disclosure and partial denial of service.\u003c/p\u003e"
}
],
"value": "An XML External Entity (XXE) injection vulnerability in the WiFi-server Spectralight application allows any authenticated user to send malicious requests, leading to arbitrary local file disclosure and partial denial of service."
}
],
"impacts": [
{
"capecId": "CAPEC-221",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-221 Data Serialization External Entities Blowup"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 8.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:N/A:L",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"baseScore": 7.1,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:L/SC:L/SI:N/SA:N",
"version": "4.0"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-611",
"description": "CWE-611 Improper Restriction of XML External Entity Reference",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-10-06T19:39:52.037Z",
"orgId": "c8b34d1a-69ae-45c3-88fe-f3b3d44f39b7",
"shortName": "Arista"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.arista.com/en/support/advisories-notices/security-advisory/24806-security-advisory-0190"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eCVE-2026-102155 has been fixed in the following releases:\u003c/p\u003e\u003cul\u003e\u003cli\u003e2026.2.1 and later releases\u003c/li\u003e\u003c/ul\u003e"
}
],
"value": "CVE-2026-102155 has been fixed in the following releases:\n- 2026.2.1 and later releases"
}
],
"source": {
"advisory": "Security Advisory 0190",
"defects": [
"BUG 1728574",
"BUG 1728163"
],
"discovery": "INTERNAL"
},
"title": "Security Advisory 0190",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eThere is no mitigation or workaround available for this issue.\u003c/p\u003e"
}
],
"value": "There is no mitigation or workaround available for this issue."
}
]
}
},
"cveMetadata": {
"assignerOrgId": "c8b34d1a-69ae-45c3-88fe-f3b3d44f39b7",
"assignerShortName": "Arista",
"cveId": "CVE-2026-102155",
"datePublished": "2026-10-06T19:39:52.037Z",
"dateReserved": "2026-09-28T17:41:09.358Z",
"dateUpdated": "2026-10-06T20:01:43.823Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-101157 (GCVE-0-2026-101157)
Vulnerability from nvd – Published: 2026-10-06 19:40 – Updated: 2026-10-06 20:05
VLAI
EPSS
VEX
Title
Security Advisory 0192
Summary
A stored cross-site scripting (XSS) vulnerability may allow an unauthenticated attacker with adjacent-network access to inject malicious content that executes when an authenticated user views affected content. Successful exploitation may allow the attacker to compromise the victim's authenticated browser session, access sensitive data, modify system state, or disrupt affected services.
Severity
8.7 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-10-06 20:05 UTC
CWE
- CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.arista.com/en/support/advisories-noti… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Arista Networks | CloudVision CUE |
Affected:
2021.2.0 , ≤ 2026.2.0
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-101157",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-10-06T20:05:27.586474Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-10-06T20:05:36.991Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"platforms": [
"CloudVision CUE on-premises, virtual appliance or physical appliance"
],
"product": "CloudVision CUE",
"vendor": "Arista Networks",
"versions": [
{
"lessThanOrEqual": "2026.2.0",
"status": "affected",
"version": "2021.2.0",
"versionType": "custom"
}
]
}
],
"configurations": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eTo be vulnerable, CV-CUE UI must be enabled and running. The status can be audited with the command \u003ccode\u003ecvpi status aware\u003c/code\u003e:\u003c/p\u003e\u003cpre\u003e[root@]# cvpi status aware\nExecuting command. This may take some time...\nCompleted 1/1 discovered actions\nprimary components total:1 running:1 disabled:0\nsecondary components total:1 running:1 disabled:0\ntertiary components total:1 running:1 disabled:0\u003c/pre\u003e"
}
],
"value": "To be vulnerable, CV-CUE UI must be enabled and running. The status can be audited with the command \"cvpi status aware\":\n\n[root@]# cvpi status aware\nExecuting command. This may take some time...\nCompleted 1/1 discovered actions\nprimary components total:1 running:1 disabled:0\nsecondary components total:1 running:1 disabled:0\ntertiary components total:1 running:1 disabled:0"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eA stored cross-site scripting (XSS) vulnerability may allow an unauthenticated attacker with adjacent-network access to inject malicious content that executes when an authenticated user views affected content. Successful exploitation may allow the attacker to compromise the victim\u0027s authenticated browser session, access sensitive data, modify system state, or disrupt affected services.\u003c/p\u003e"
}
],
"value": "A stored cross-site scripting (XSS) vulnerability may allow an unauthenticated attacker with adjacent-network access to inject malicious content that executes when an authenticated user views affected content. Successful exploitation may allow the attacker to compromise the victim\u0027s authenticated browser session, access sensitive data, modify system state, or disrupt affected services."
}
],
"impacts": [
{
"capecId": "CAPEC-86",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-86 XSS Using HTTP Query Strings"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:L",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"baseScore": 9.3,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:L/SC:H/SI:H/SA:L",
"version": "4.0"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-10-06T19:40:29.387Z",
"orgId": "c8b34d1a-69ae-45c3-88fe-f3b3d44f39b7",
"shortName": "Arista"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.arista.com/en/support/advisories-notices/security-advisory/24808-security-advisory-0192"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eCVE-2026-101157 has been fixed in the following releases:\u003c/p\u003e\u003cul\u003e\u003cli\u003e2026.2.1 and later releases\u003c/li\u003e\u003c/ul\u003e"
}
],
"value": "CVE-2026-101157 has been fixed in the following releases:\n- 2026.2.1 and later releases"
}
],
"source": {
"advisory": "Security Advisory 0192",
"defects": [
"BUG 1802841"
],
"discovery": "INTERNAL"
},
"title": "Security Advisory 0192",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eThere is no mitigation or workaround available for this issue.\u003c/p\u003e"
}
],
"value": "There is no mitigation or workaround available for this issue."
}
]
}
},
"cveMetadata": {
"assignerOrgId": "c8b34d1a-69ae-45c3-88fe-f3b3d44f39b7",
"assignerShortName": "Arista",
"cveId": "CVE-2026-101157",
"datePublished": "2026-10-06T19:40:29.387Z",
"dateReserved": "2026-09-28T08:30:31.034Z",
"dateUpdated": "2026-10-06T20:05:36.991Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-101156 (GCVE-0-2026-101156)
Vulnerability from nvd – Published: 2026-10-06 19:40 – Updated: 2026-10-06 20:05
VLAI
EPSS
VEX
Title
Security Advisory 0192
Summary
A stored cross-site scripting (XSS) vulnerability may allow an authenticated, high-privilege administrator to store malicious content in a configuration. The content may execute in another authenticated user's browser when that user views or compares the affected configuration. Successful exploitation may allow the attacker to act through the victim's authenticated browser session to access sensitive data, modify configurations, or disrupt managed wireless services.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-10-06 20:04 UTC
CWE
- CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.arista.com/en/support/advisories-noti… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Arista Networks | CloudVision CUE |
Affected:
2025.2.0 , ≤ 2026.2.0
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-101156",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-10-06T20:04:54.409170Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-10-06T20:05:03.281Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"platforms": [
"CloudVision CUE on-premises, virtual appliance or physical appliance"
],
"product": "CloudVision CUE",
"vendor": "Arista Networks",
"versions": [
{
"lessThanOrEqual": "2026.2.0",
"status": "affected",
"version": "2025.2.0",
"versionType": "custom"
}
]
}
],
"configurations": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eTo be vulnerable, CV-CUE UI must be enabled and running. The status can be audited with the command \u003ccode\u003ecvpi status aware\u003c/code\u003e:\u003c/p\u003e\u003cpre\u003e[root@]# cvpi status aware\nExecuting command. This may take some time...\nCompleted 1/1 discovered actions\nprimary components total:1 running:1 disabled:0\nsecondary components total:1 running:1 disabled:0\ntertiary components total:1 running:1 disabled:0\u003c/pre\u003e"
}
],
"value": "To be vulnerable, CV-CUE UI must be enabled and running. The status can be audited with the command \"cvpi status aware\":\n\n[root@]# cvpi status aware\nExecuting command. This may take some time...\nCompleted 1/1 discovered actions\nprimary components total:1 running:1 disabled:0\nsecondary components total:1 running:1 disabled:0\ntertiary components total:1 running:1 disabled:0"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eA stored cross-site scripting (XSS) vulnerability may allow an authenticated, high-privilege administrator to store malicious content in a configuration. The content may execute in another authenticated user\u0027s browser when that user views or compares the affected configuration. Successful exploitation may allow the attacker to act through the victim\u0027s authenticated browser session to access sensitive data, modify configurations, or disrupt managed wireless services.\u003c/p\u003e"
}
],
"value": "A stored cross-site scripting (XSS) vulnerability may allow an authenticated, high-privilege administrator to store malicious content in a configuration. The content may execute in another authenticated user\u0027s browser when that user views or compares the affected configuration. Successful exploitation may allow the attacker to act through the victim\u0027s authenticated browser session to access sensitive data, modify configurations, or disrupt managed wireless services."
}
],
"impacts": [
{
"capecId": "CAPEC-86",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-86 XSS Using HTTP Query Strings"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 8.4,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"baseScore": 6.2,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:A/VC:N/VI:N/VA:N/SC:H/SI:H/SA:H",
"version": "4.0"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-10-06T19:40:28.902Z",
"orgId": "c8b34d1a-69ae-45c3-88fe-f3b3d44f39b7",
"shortName": "Arista"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.arista.com/en/support/advisories-notices/security-advisory/24808-security-advisory-0192"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eCVE-2026-101156 has been fixed in the following releases:\u003c/p\u003e\u003cul\u003e\u003cli\u003e2026.2.1 and later releases\u003c/li\u003e\u003c/ul\u003e"
}
],
"value": "CVE-2026-101156 has been fixed in the following releases:\n- 2026.2.1 and later releases"
}
],
"source": {
"advisory": "Security Advisory 0192",
"defects": [
"BUG 1782052"
],
"discovery": "INTERNAL"
},
"title": "Security Advisory 0192",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eThere is no mitigation or workaround available for this issue.\u003c/p\u003e"
}
],
"value": "There is no mitigation or workaround available for this issue."
}
]
}
},
"cveMetadata": {
"assignerOrgId": "c8b34d1a-69ae-45c3-88fe-f3b3d44f39b7",
"assignerShortName": "Arista",
"cveId": "CVE-2026-101156",
"datePublished": "2026-10-06T19:40:28.902Z",
"dateReserved": "2026-09-28T08:30:31.034Z",
"dateUpdated": "2026-10-06T20:05:03.281Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-101157 (GCVE-0-2026-101157)
Vulnerability from cvelistv5 – Published: 2026-10-06 19:40 – Updated: 2026-10-06 20:05
VLAI
EPSS
VEX
Title
Security Advisory 0192
Summary
A stored cross-site scripting (XSS) vulnerability may allow an unauthenticated attacker with adjacent-network access to inject malicious content that executes when an authenticated user views affected content. Successful exploitation may allow the attacker to compromise the victim's authenticated browser session, access sensitive data, modify system state, or disrupt affected services.
Severity
8.7 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-10-06 20:05 UTC
CWE
- CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.arista.com/en/support/advisories-noti… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Arista Networks | CloudVision CUE |
Affected:
2021.2.0 , ≤ 2026.2.0
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-101157",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-10-06T20:05:27.586474Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-10-06T20:05:36.991Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"platforms": [
"CloudVision CUE on-premises, virtual appliance or physical appliance"
],
"product": "CloudVision CUE",
"vendor": "Arista Networks",
"versions": [
{
"lessThanOrEqual": "2026.2.0",
"status": "affected",
"version": "2021.2.0",
"versionType": "custom"
}
]
}
],
"configurations": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eTo be vulnerable, CV-CUE UI must be enabled and running. The status can be audited with the command \u003ccode\u003ecvpi status aware\u003c/code\u003e:\u003c/p\u003e\u003cpre\u003e[root@]# cvpi status aware\nExecuting command. This may take some time...\nCompleted 1/1 discovered actions\nprimary components total:1 running:1 disabled:0\nsecondary components total:1 running:1 disabled:0\ntertiary components total:1 running:1 disabled:0\u003c/pre\u003e"
}
],
"value": "To be vulnerable, CV-CUE UI must be enabled and running. The status can be audited with the command \"cvpi status aware\":\n\n[root@]# cvpi status aware\nExecuting command. This may take some time...\nCompleted 1/1 discovered actions\nprimary components total:1 running:1 disabled:0\nsecondary components total:1 running:1 disabled:0\ntertiary components total:1 running:1 disabled:0"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eA stored cross-site scripting (XSS) vulnerability may allow an unauthenticated attacker with adjacent-network access to inject malicious content that executes when an authenticated user views affected content. Successful exploitation may allow the attacker to compromise the victim\u0027s authenticated browser session, access sensitive data, modify system state, or disrupt affected services.\u003c/p\u003e"
}
],
"value": "A stored cross-site scripting (XSS) vulnerability may allow an unauthenticated attacker with adjacent-network access to inject malicious content that executes when an authenticated user views affected content. Successful exploitation may allow the attacker to compromise the victim\u0027s authenticated browser session, access sensitive data, modify system state, or disrupt affected services."
}
],
"impacts": [
{
"capecId": "CAPEC-86",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-86 XSS Using HTTP Query Strings"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:L",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"baseScore": 9.3,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:L/SC:H/SI:H/SA:L",
"version": "4.0"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-10-06T19:40:29.387Z",
"orgId": "c8b34d1a-69ae-45c3-88fe-f3b3d44f39b7",
"shortName": "Arista"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.arista.com/en/support/advisories-notices/security-advisory/24808-security-advisory-0192"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eCVE-2026-101157 has been fixed in the following releases:\u003c/p\u003e\u003cul\u003e\u003cli\u003e2026.2.1 and later releases\u003c/li\u003e\u003c/ul\u003e"
}
],
"value": "CVE-2026-101157 has been fixed in the following releases:\n- 2026.2.1 and later releases"
}
],
"source": {
"advisory": "Security Advisory 0192",
"defects": [
"BUG 1802841"
],
"discovery": "INTERNAL"
},
"title": "Security Advisory 0192",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eThere is no mitigation or workaround available for this issue.\u003c/p\u003e"
}
],
"value": "There is no mitigation or workaround available for this issue."
}
]
}
},
"cveMetadata": {
"assignerOrgId": "c8b34d1a-69ae-45c3-88fe-f3b3d44f39b7",
"assignerShortName": "Arista",
"cveId": "CVE-2026-101157",
"datePublished": "2026-10-06T19:40:29.387Z",
"dateReserved": "2026-09-28T08:30:31.034Z",
"dateUpdated": "2026-10-06T20:05:36.991Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-101156 (GCVE-0-2026-101156)
Vulnerability from cvelistv5 – Published: 2026-10-06 19:40 – Updated: 2026-10-06 20:05
VLAI
EPSS
VEX
Title
Security Advisory 0192
Summary
A stored cross-site scripting (XSS) vulnerability may allow an authenticated, high-privilege administrator to store malicious content in a configuration. The content may execute in another authenticated user's browser when that user views or compares the affected configuration. Successful exploitation may allow the attacker to act through the victim's authenticated browser session to access sensitive data, modify configurations, or disrupt managed wireless services.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-10-06 20:04 UTC
CWE
- CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.arista.com/en/support/advisories-noti… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Arista Networks | CloudVision CUE |
Affected:
2025.2.0 , ≤ 2026.2.0
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-101156",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-10-06T20:04:54.409170Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-10-06T20:05:03.281Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"platforms": [
"CloudVision CUE on-premises, virtual appliance or physical appliance"
],
"product": "CloudVision CUE",
"vendor": "Arista Networks",
"versions": [
{
"lessThanOrEqual": "2026.2.0",
"status": "affected",
"version": "2025.2.0",
"versionType": "custom"
}
]
}
],
"configurations": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eTo be vulnerable, CV-CUE UI must be enabled and running. The status can be audited with the command \u003ccode\u003ecvpi status aware\u003c/code\u003e:\u003c/p\u003e\u003cpre\u003e[root@]# cvpi status aware\nExecuting command. This may take some time...\nCompleted 1/1 discovered actions\nprimary components total:1 running:1 disabled:0\nsecondary components total:1 running:1 disabled:0\ntertiary components total:1 running:1 disabled:0\u003c/pre\u003e"
}
],
"value": "To be vulnerable, CV-CUE UI must be enabled and running. The status can be audited with the command \"cvpi status aware\":\n\n[root@]# cvpi status aware\nExecuting command. This may take some time...\nCompleted 1/1 discovered actions\nprimary components total:1 running:1 disabled:0\nsecondary components total:1 running:1 disabled:0\ntertiary components total:1 running:1 disabled:0"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eA stored cross-site scripting (XSS) vulnerability may allow an authenticated, high-privilege administrator to store malicious content in a configuration. The content may execute in another authenticated user\u0027s browser when that user views or compares the affected configuration. Successful exploitation may allow the attacker to act through the victim\u0027s authenticated browser session to access sensitive data, modify configurations, or disrupt managed wireless services.\u003c/p\u003e"
}
],
"value": "A stored cross-site scripting (XSS) vulnerability may allow an authenticated, high-privilege administrator to store malicious content in a configuration. The content may execute in another authenticated user\u0027s browser when that user views or compares the affected configuration. Successful exploitation may allow the attacker to act through the victim\u0027s authenticated browser session to access sensitive data, modify configurations, or disrupt managed wireless services."
}
],
"impacts": [
{
"capecId": "CAPEC-86",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-86 XSS Using HTTP Query Strings"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 8.4,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"baseScore": 6.2,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:A/VC:N/VI:N/VA:N/SC:H/SI:H/SA:H",
"version": "4.0"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-10-06T19:40:28.902Z",
"orgId": "c8b34d1a-69ae-45c3-88fe-f3b3d44f39b7",
"shortName": "Arista"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.arista.com/en/support/advisories-notices/security-advisory/24808-security-advisory-0192"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eCVE-2026-101156 has been fixed in the following releases:\u003c/p\u003e\u003cul\u003e\u003cli\u003e2026.2.1 and later releases\u003c/li\u003e\u003c/ul\u003e"
}
],
"value": "CVE-2026-101156 has been fixed in the following releases:\n- 2026.2.1 and later releases"
}
],
"source": {
"advisory": "Security Advisory 0192",
"defects": [
"BUG 1782052"
],
"discovery": "INTERNAL"
},
"title": "Security Advisory 0192",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eThere is no mitigation or workaround available for this issue.\u003c/p\u003e"
}
],
"value": "There is no mitigation or workaround available for this issue."
}
]
}
},
"cveMetadata": {
"assignerOrgId": "c8b34d1a-69ae-45c3-88fe-f3b3d44f39b7",
"assignerShortName": "Arista",
"cveId": "CVE-2026-101156",
"datePublished": "2026-10-06T19:40:28.902Z",
"dateReserved": "2026-09-28T08:30:31.034Z",
"dateUpdated": "2026-10-06T20:05:03.281Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-102156 (GCVE-0-2026-102156)
Vulnerability from cvelistv5 – Published: 2026-10-06 19:40 – Updated: 2026-10-06 20:04
VLAI
EPSS
VEX
Title
Security Advisory 0191
Summary
Improper neutralization of Lightweight Directory Access Protocol (LDAP) authentication input may allow an unauthenticated network attacker, under high-complexity conditions, to inject queries against the configured directory service.
Severity
6.8 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-10-06 20:04 UTC
CWE
- CWE-74 - Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.arista.com/en/support/advisories-noti… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Arista Networks | CloudVision CUE |
Affected:
2021.2.0 , ≤ 2026.2.0
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-102156",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-10-06T20:04:24.354512Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-10-06T20:04:33.983Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"platforms": [
"CloudVision CUE on-premises, virtual appliance or physical appliance"
],
"product": "CloudVision CUE",
"vendor": "Arista Networks",
"versions": [
{
"lessThanOrEqual": "2026.2.0",
"status": "affected",
"version": "2021.2.0",
"versionType": "custom"
}
]
}
],
"configurations": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eBoth of the following conditions must be met:\u003c/p\u003e\u003col\u003e\u003cli\u003eCV-CUE backend (wifimanager) must be enabled and running.\u003c/li\u003e\u003cli\u003eLDAP authentication must be enabled for the User Accounts.\u003c/li\u003e\u003c/ol\u003e\u003cp\u003eTo inspect the status of wifimanager:\u003c/p\u003e\u003cpre\u003e[root@]# cvpi status wifimanager\nExecuting command. This may take some time...\nCompleted 1/1 discovered actions\nprimary components total:1 running:1 disabled:0\u003c/pre\u003e"
}
],
"value": "Both of the following conditions must be met:\n1. CV-CUE backend (wifimanager) must be enabled and running.\n2. LDAP authentication must be enabled for the User Accounts.\n\nTo inspect the status of wifimanager:\n[root@]# cvpi status wifimanager\nExecuting command. This may take some time...\nCompleted 1/1 discovered actions\nprimary components total:1 running:1 disabled:0"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eImproper neutralization of Lightweight Directory Access Protocol (LDAP) authentication input may allow an unauthenticated network attacker, under high-complexity conditions, to inject queries against the configured directory service.\u003c/p\u003e"
}
],
"value": "Improper neutralization of Lightweight Directory Access Protocol (LDAP) authentication input may allow an unauthenticated network attacker, under high-complexity conditions, to inject queries against the configured directory service."
}
],
"impacts": [
{
"capecId": "CAPEC-136",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-136 LDAP Injection"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 6.8,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"baseScore": 6.9,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:N/VC:N/VI:N/VA:N/SC:H/SI:N/SA:N",
"version": "4.0"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-74",
"description": "CWE-74 Improper Neutralization of Special Elements in Output Used by a Downstream Component (\u0027Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-10-06T19:40:28.369Z",
"orgId": "c8b34d1a-69ae-45c3-88fe-f3b3d44f39b7",
"shortName": "Arista"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.arista.com/en/support/advisories-notices/security-advisory/24807-security-advisory-0191"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eCVE-2026-102156 has been fixed in the following releases:\u003c/p\u003e\u003cul\u003e\u003cli\u003e2026.2.1 and later releases\u003c/li\u003e\u003c/ul\u003e"
}
],
"value": "CVE-2026-102156 has been fixed in the following releases:\n- 2026.2.1 and later releases"
}
],
"source": {
"advisory": "Security Advisory 0191",
"defects": [
"BUG 1731907"
],
"discovery": "INTERNAL"
},
"title": "Security Advisory 0191",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eThe recommended mitigation is to disable LDAP Authentication. Prior to implementing this, please ensure that an alternative authentication mechanism is properly configured and verified, as disabling LDAP authentication will prevent LDAP-dependent users from accessing or managing CV-CUE.\u003c/p\u003e"
}
],
"value": "The recommended mitigation is to disable LDAP Authentication. Prior to implementing this, please ensure that an alternative authentication mechanism is properly configured and verified, as disabling LDAP authentication will prevent LDAP-dependent users from accessing or managing CV-CUE."
}
]
}
},
"cveMetadata": {
"assignerOrgId": "c8b34d1a-69ae-45c3-88fe-f3b3d44f39b7",
"assignerShortName": "Arista",
"cveId": "CVE-2026-102156",
"datePublished": "2026-10-06T19:40:28.369Z",
"dateReserved": "2026-09-28T17:41:09.358Z",
"dateUpdated": "2026-10-06T20:04:33.983Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-102161 (GCVE-0-2026-102161)
Vulnerability from cvelistv5 – Published: 2026-10-06 19:39 – Updated: 2026-10-06 20:04
VLAI
EPSS
VEX
Title
Security Advisory 0190
Summary
An unauthenticated attacker located on an adjacent private network (or any attacker routed through a reverse proxy/load balancer that forwards client headers) can forge their source IP address and gain administrative session privileges on the CV-CUE backend.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-10-06 20:04 UTC
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.arista.com/en/support/advisories-noti… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Arista Networks | CloudVision CUE |
Affected:
2021.2.0 , ≤ 2026.2.0
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-102161",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-10-06T20:04:00.722473Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-10-06T20:04:10.245Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"platforms": [
"CloudVision CUE on-premises, virtual appliance or physical appliance"
],
"product": "CloudVision CUE",
"vendor": "Arista Networks",
"versions": [
{
"lessThanOrEqual": "2026.2.0",
"status": "affected",
"version": "2021.2.0",
"versionType": "custom"
}
]
}
],
"configurations": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eTo be vulnerable, CV-CUE backend (wifimanager) must be enabled and running. To inspect the status of wifimanager:\u003c/p\u003e\u003cpre\u003e[root@]# cvpi status wifimanager\nExecuting command. This may take some time...\nCompleted 1/1 discovered actions\nprimary components total:1 running:1 disabled:0\u003c/pre\u003e"
}
],
"value": "To be vulnerable, CV-CUE backend (wifimanager) must be enabled and running. To inspect the status of wifimanager:\n\n[root@]# cvpi status wifimanager\nExecuting command. This may take some time...\nCompleted 1/1 discovered actions\nprimary components total:1 running:1 disabled:0"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eAn unauthenticated attacker located on an adjacent private network (or any attacker routed through a reverse proxy/load balancer that forwards client headers) can forge their source IP address and gain administrative session privileges on the CV-CUE backend.\u003c/p\u003e"
}
],
"value": "An unauthenticated attacker located on an adjacent private network (or any attacker routed through a reverse proxy/load balancer that forwards client headers) can forge their source IP address and gain administrative session privileges on the CV-CUE backend."
}
],
"impacts": [
{
"capecId": "CAPEC-194",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-194 Fake the Source of Data"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-798",
"description": "CWE-798 Use of Hard-coded Credentials",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-290",
"description": "CWE-290 Authentication Bypass by Spoofing",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-10-06T19:39:54.646Z",
"orgId": "c8b34d1a-69ae-45c3-88fe-f3b3d44f39b7",
"shortName": "Arista"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.arista.com/en/support/advisories-notices/security-advisory/24806-security-advisory-0190"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eCVE-2026-102161 has been fixed in the following releases:\u003c/p\u003e\u003cul\u003e\u003cli\u003e2026.2.1 and later releases\u003c/li\u003e\u003c/ul\u003e"
}
],
"value": "CVE-2026-102161 has been fixed in the following releases:\n- 2026.2.1 and later releases"
}
],
"source": {
"advisory": "Security Advisory 0190",
"defects": [
"BUG 1728203"
],
"discovery": "INTERNAL"
},
"title": "Security Advisory 0190",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eThere is no mitigation or workaround available for this issue.\u003c/p\u003e"
}
],
"value": "There is no mitigation or workaround available for this issue."
}
]
}
},
"cveMetadata": {
"assignerOrgId": "c8b34d1a-69ae-45c3-88fe-f3b3d44f39b7",
"assignerShortName": "Arista",
"cveId": "CVE-2026-102161",
"datePublished": "2026-10-06T19:39:54.646Z",
"dateReserved": "2026-09-28T17:41:09.358Z",
"dateUpdated": "2026-10-06T20:04:10.245Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-102160 (GCVE-0-2026-102160)
Vulnerability from cvelistv5 – Published: 2026-10-06 19:39 – Updated: 2026-10-06 20:03
VLAI
EPSS
VEX
Title
Security Advisory 0190
Summary
An operating system (OS) command injection vulnerability in CloudVision CUE backup management may allow an authenticated Super User to submit a crafted backup request and execute arbitrary commands with the privileges of the affected service.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-10-06 20:03 UTC
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.arista.com/en/support/advisories-noti… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Arista Networks | CloudVision CUE |
Affected:
2021.2.0 , ≤ 2026.2.0
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-102160",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-10-06T20:03:34.193659Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-10-06T20:03:43.702Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"platforms": [
"CloudVision CUE on-premises, virtual appliance or physical appliance"
],
"product": "CloudVision CUE",
"vendor": "Arista Networks",
"versions": [
{
"lessThanOrEqual": "2026.2.0",
"status": "affected",
"version": "2021.2.0",
"versionType": "custom"
}
]
}
],
"configurations": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eTo be vulnerable, CV-CUE backend (wifimanager) must be enabled and running. To inspect the status of wifimanager:\u003c/p\u003e\u003cpre\u003e[root@]# cvpi status wifimanager\nExecuting command. This may take some time...\nCompleted 1/1 discovered actions\nprimary components total:1 running:1 disabled:0\u003c/pre\u003e"
}
],
"value": "To be vulnerable, CV-CUE backend (wifimanager) must be enabled and running. To inspect the status of wifimanager:\n\n[root@]# cvpi status wifimanager\nExecuting command. This may take some time...\nCompleted 1/1 discovered actions\nprimary components total:1 running:1 disabled:0"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eAn operating system (OS) command injection vulnerability in CloudVision CUE backup management may allow an authenticated Super User to submit a crafted backup request and execute arbitrary commands with the privileges of the affected service.\u003c/p\u003e"
}
],
"value": "An operating system (OS) command injection vulnerability in CloudVision CUE backup management may allow an authenticated Super User to submit a crafted backup request and execute arbitrary commands with the privileges of the affected service."
}
],
"impacts": [
{
"capecId": "CAPEC-88",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-88 OS Command Injection"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.2,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"baseScore": 8.6,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-10-06T19:39:54.096Z",
"orgId": "c8b34d1a-69ae-45c3-88fe-f3b3d44f39b7",
"shortName": "Arista"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.arista.com/en/support/advisories-notices/security-advisory/24806-security-advisory-0190"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eCVE-2026-102160 has been fixed in the following releases:\u003c/p\u003e\u003cul\u003e\u003cli\u003e2026.2.1 and later releases\u003c/li\u003e\u003c/ul\u003e"
}
],
"value": "CVE-2026-102160 has been fixed in the following releases:\n- 2026.2.1 and later releases"
}
],
"source": {
"advisory": "Security Advisory 0190",
"defects": [
"BUG 1728182"
],
"discovery": "INTERNAL"
},
"title": "Security Advisory 0190",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eThere is no mitigation or workaround available for this issue.\u003c/p\u003e"
}
],
"value": "There is no mitigation or workaround available for this issue."
}
]
}
},
"cveMetadata": {
"assignerOrgId": "c8b34d1a-69ae-45c3-88fe-f3b3d44f39b7",
"assignerShortName": "Arista",
"cveId": "CVE-2026-102160",
"datePublished": "2026-10-06T19:39:54.096Z",
"dateReserved": "2026-09-28T17:41:09.358Z",
"dateUpdated": "2026-10-06T20:03:43.702Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-102159 (GCVE-0-2026-102159)
Vulnerability from cvelistv5 – Published: 2026-10-06 19:39 – Updated: 2026-10-06 20:03
VLAI
EPSS
VEX
Title
Security Advisory 0190
Summary
An access-control flaw in the CV-CUE backend may allow an unauthenticated network attacker to access functionality intended only for internal services. Successful exploitation may expose sensitive location information or disrupt affected services.
Severity
9.8 (Critical)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-10-06 20:03 UTC
CWE
- CWE-306 - Missing Authentication for Critical Function
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.arista.com/en/support/advisories-noti… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Arista Networks | CloudVision CUE |
Affected:
2022.3.0 , ≤ 2026.2.0
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-102159",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-10-06T20:03:00.815750Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-10-06T20:03:15.078Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"platforms": [
"CloudVision CUE on-premises, virtual appliance or physical appliance"
],
"product": "CloudVision CUE",
"vendor": "Arista Networks",
"versions": [
{
"lessThanOrEqual": "2026.2.0",
"status": "affected",
"version": "2022.3.0",
"versionType": "custom"
}
]
}
],
"configurations": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eTo be vulnerable, CV-CUE backend (wifimanager) must be enabled and running. To inspect the status of wifimanager:\u003c/p\u003e\u003cpre\u003e[root@]# cvpi status wifimanager\nExecuting command. This may take some time...\nCompleted 1/1 discovered actions\nprimary components total:1 running:1 disabled:0\u003c/pre\u003e"
}
],
"value": "To be vulnerable, CV-CUE backend (wifimanager) must be enabled and running. To inspect the status of wifimanager:\n\n[root@]# cvpi status wifimanager\nExecuting command. This may take some time...\nCompleted 1/1 discovered actions\nprimary components total:1 running:1 disabled:0"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eAn access-control flaw in the CV-CUE backend may allow an unauthenticated network attacker to access functionality intended only for internal services. Successful exploitation may expose sensitive location information or disrupt affected services.\u003c/p\u003e"
}
],
"value": "An access-control flaw in the CV-CUE backend may allow an unauthenticated network attacker to access functionality intended only for internal services. Successful exploitation may expose sensitive location information or disrupt affected services."
}
],
"impacts": [
{
"capecId": "CAPEC-115",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-115 Authentication Bypass"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"baseScore": 9.3,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306 Missing Authentication for Critical Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-10-06T19:39:53.582Z",
"orgId": "c8b34d1a-69ae-45c3-88fe-f3b3d44f39b7",
"shortName": "Arista"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.arista.com/en/support/advisories-notices/security-advisory/24806-security-advisory-0190"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eCVE-2026-102159 has been fixed in the following releases:\u003c/p\u003e\u003cul\u003e\u003cli\u003e2026.2.1 and later releases\u003c/li\u003e\u003c/ul\u003e"
}
],
"value": "CVE-2026-102159 has been fixed in the following releases:\n- 2026.2.1 and later releases"
}
],
"source": {
"advisory": "Security Advisory 0190",
"defects": [
"BUG 1732043"
],
"discovery": "INTERNAL"
},
"title": "Security Advisory 0190",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eThere is no mitigation or workaround available for this issue.\u003c/p\u003e"
}
],
"value": "There is no mitigation or workaround available for this issue."
}
]
}
},
"cveMetadata": {
"assignerOrgId": "c8b34d1a-69ae-45c3-88fe-f3b3d44f39b7",
"assignerShortName": "Arista",
"cveId": "CVE-2026-102159",
"datePublished": "2026-10-06T19:39:53.582Z",
"dateReserved": "2026-09-28T17:41:09.358Z",
"dateUpdated": "2026-10-06T20:03:15.078Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-102158 (GCVE-0-2026-102158)
Vulnerability from cvelistv5 – Published: 2026-10-06 19:39 – Updated: 2026-10-06 20:02
VLAI
EPSS
VEX
Title
Security Advisory 0190
Summary
Improper validation of selected CloudVision CUE application programming interface (API) request parameters may allow an authenticated network user to perform SQL injection against the backend impacting its availability.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-10-06 20:02 UTC
CWE
- CWE-74 - Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.arista.com/en/support/advisories-noti… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Arista Networks | CloudVision CUE |
Affected:
2022.2.0 , ≤ 2026.2.0
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-102158",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-10-06T20:02:19.932346Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-10-06T20:02:40.724Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"platforms": [
"CloudVision CUE on-premises, virtual appliance or physical appliance"
],
"product": "CloudVision CUE",
"vendor": "Arista Networks",
"versions": [
{
"lessThanOrEqual": "2026.2.0",
"status": "affected",
"version": "2022.2.0",
"versionType": "custom"
}
]
}
],
"configurations": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eTo be vulnerable, CV-CUE backend (wifimanager) must be enabled and running. To inspect the status of wifimanager:\u003c/p\u003e\u003cpre\u003e[root@]# cvpi status wifimanager\nExecuting command. This may take some time...\nCompleted 1/1 discovered actions\nprimary components total:1 running:1 disabled:0\u003c/pre\u003e"
}
],
"value": "To be vulnerable, CV-CUE backend (wifimanager) must be enabled and running. To inspect the status of wifimanager:\n\n[root@]# cvpi status wifimanager\nExecuting command. This may take some time...\nCompleted 1/1 discovered actions\nprimary components total:1 running:1 disabled:0"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eImproper validation of selected CloudVision CUE application programming interface (API) request parameters may allow an authenticated network user to perform SQL injection against the backend impacting its availability.\u003c/p\u003e"
}
],
"value": "Improper validation of selected CloudVision CUE application programming interface (API) request parameters may allow an authenticated network user to perform SQL injection against the backend impacting its availability."
}
],
"impacts": [
{
"capecId": "CAPEC-66",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-66 SQL Injection"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"baseScore": 7.1,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-74",
"description": "CWE-74 Improper Neutralization of Special Elements in Output Used by a Downstream Component (\u0027Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-10-06T19:39:53.096Z",
"orgId": "c8b34d1a-69ae-45c3-88fe-f3b3d44f39b7",
"shortName": "Arista"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.arista.com/en/support/advisories-notices/security-advisory/24806-security-advisory-0190"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eCVE-2026-102158 has been fixed in the following releases:\u003c/p\u003e\u003cul\u003e\u003cli\u003e2026.2.1 and later releases\u003c/li\u003e\u003c/ul\u003e"
}
],
"value": "CVE-2026-102158 has been fixed in the following releases:\n- 2026.2.1 and later releases"
}
],
"source": {
"advisory": "Security Advisory 0190",
"defects": [
"BUG 1731886"
],
"discovery": "INTERNAL"
},
"title": "Security Advisory 0190",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eThere is no mitigation or workaround available for this issue.\u003c/p\u003e"
}
],
"value": "There is no mitigation or workaround available for this issue."
}
]
}
},
"cveMetadata": {
"assignerOrgId": "c8b34d1a-69ae-45c3-88fe-f3b3d44f39b7",
"assignerShortName": "Arista",
"cveId": "CVE-2026-102158",
"datePublished": "2026-10-06T19:39:53.096Z",
"dateReserved": "2026-09-28T17:41:09.358Z",
"dateUpdated": "2026-10-06T20:02:40.724Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-102157 (GCVE-0-2026-102157)
Vulnerability from cvelistv5 – Published: 2026-10-06 19:39 – Updated: 2026-10-06 20:02
VLAI
EPSS
VEX
Title
Security Advisory 0190
Summary
An insecure direct object reference (IDOR) vulnerability in a CloudVision CUE file-serving interface may allow an authenticated network user, under specific attack conditions, to access another user's transient data.
Severity
5.9 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-10-06 20:01 UTC
CWE
- CWE-639 - Authorization Bypass Through User-Controlled Key
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.arista.com/en/support/advisories-noti… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Arista Networks | CloudVision CUE |
Affected:
2021.2.0 , ≤ 2026.2.0
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-102157",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-10-06T20:01:56.142507Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-10-06T20:02:04.283Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"platforms": [
"CloudVision CUE on-premises, virtual appliance or physical appliance"
],
"product": "CloudVision CUE",
"vendor": "Arista Networks",
"versions": [
{
"lessThanOrEqual": "2026.2.0",
"status": "affected",
"version": "2021.2.0",
"versionType": "custom"
}
]
}
],
"configurations": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eTo be vulnerable, CV-CUE backend (wifimanager) must be enabled and running. To inspect the status of wifimanager:\u003c/p\u003e\u003cpre\u003e[root@]# cvpi status wifimanager\nExecuting command. This may take some time...\nCompleted 1/1 discovered actions\nprimary components total:1 running:1 disabled:0\u003c/pre\u003e"
}
],
"value": "To be vulnerable, CV-CUE backend (wifimanager) must be enabled and running. To inspect the status of wifimanager:\n\n[root@]# cvpi status wifimanager\nExecuting command. This may take some time...\nCompleted 1/1 discovered actions\nprimary components total:1 running:1 disabled:0"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eAn insecure direct object reference (IDOR) vulnerability in a CloudVision CUE file-serving interface may allow an authenticated network user, under specific attack conditions, to access another user\u0027s transient data.\u003c/p\u003e"
}
],
"value": "An insecure direct object reference (IDOR) vulnerability in a CloudVision CUE file-serving interface may allow an authenticated network user, under specific attack conditions, to access another user\u0027s transient data."
}
],
"impacts": [
{
"capecId": "CAPEC-1",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-1 Accessing Functionality Not Properly Constrained by ACLs"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 5.9,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:N/A:L",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"baseScore": 6.8,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:L/UI:N/VC:H/VI:N/VA:L/SC:N/SI:N/SA:N",
"version": "4.0"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-639",
"description": "CWE-639 Authorization Bypass Through User-Controlled Key",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-10-06T19:39:52.569Z",
"orgId": "c8b34d1a-69ae-45c3-88fe-f3b3d44f39b7",
"shortName": "Arista"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.arista.com/en/support/advisories-notices/security-advisory/24806-security-advisory-0190"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eCVE-2026-102157 has been fixed in the following releases:\u003c/p\u003e\u003cul\u003e\u003cli\u003e2026.2.1 and later releases\u003c/li\u003e\u003c/ul\u003e"
}
],
"value": "CVE-2026-102157 has been fixed in the following releases:\n- 2026.2.1 and later releases"
}
],
"source": {
"advisory": "Security Advisory 0190",
"defects": [
"BUG 1728161"
],
"discovery": "INTERNAL"
},
"title": "Security Advisory 0190",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eThere is no mitigation or workaround available for this issue.\u003c/p\u003e"
}
],
"value": "There is no mitigation or workaround available for this issue."
}
]
}
},
"cveMetadata": {
"assignerOrgId": "c8b34d1a-69ae-45c3-88fe-f3b3d44f39b7",
"assignerShortName": "Arista",
"cveId": "CVE-2026-102157",
"datePublished": "2026-10-06T19:39:52.569Z",
"dateReserved": "2026-09-28T17:41:09.358Z",
"dateUpdated": "2026-10-06T20:02:04.283Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-102155 (GCVE-0-2026-102155)
Vulnerability from cvelistv5 – Published: 2026-10-06 19:39 – Updated: 2026-10-06 20:01
VLAI
EPSS
VEX
Title
Security Advisory 0190
Summary
An XML External Entity (XXE) injection vulnerability in the WiFi-server Spectralight application allows any authenticated user to send malicious requests, leading to arbitrary local file disclosure and partial denial of service.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-10-06 20:01 UTC
CWE
- CWE-611 - Improper Restriction of XML External Entity Reference
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.arista.com/en/support/advisories-noti… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Arista Networks | CloudVision CUE |
Affected:
2021.2.0 , ≤ 2026.2.0
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-102155",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-10-06T20:01:34.634435Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-10-06T20:01:43.823Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"platforms": [
"CloudVision CUE on-premises, virtual appliance or physical appliance"
],
"product": "CloudVision CUE",
"vendor": "Arista Networks",
"versions": [
{
"lessThanOrEqual": "2026.2.0",
"status": "affected",
"version": "2021.2.0",
"versionType": "custom"
}
]
}
],
"configurations": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eTo be vulnerable, CV-CUE backend (wifimanager) must be enabled and running. To inspect the status of wifimanager:\u003c/p\u003e\u003cpre\u003e[root@]# cvpi status wifimanager\nExecuting command. This may take some time...\nCompleted 1/1 discovered actions\nprimary components total:1 running:1 disabled:0\u003c/pre\u003e"
}
],
"value": "To be vulnerable, CV-CUE backend (wifimanager) must be enabled and running. To inspect the status of wifimanager:\n\n[root@]# cvpi status wifimanager\nExecuting command. This may take some time...\nCompleted 1/1 discovered actions\nprimary components total:1 running:1 disabled:0"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eAn XML External Entity (XXE) injection vulnerability in the WiFi-server Spectralight application allows any authenticated user to send malicious requests, leading to arbitrary local file disclosure and partial denial of service.\u003c/p\u003e"
}
],
"value": "An XML External Entity (XXE) injection vulnerability in the WiFi-server Spectralight application allows any authenticated user to send malicious requests, leading to arbitrary local file disclosure and partial denial of service."
}
],
"impacts": [
{
"capecId": "CAPEC-221",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-221 Data Serialization External Entities Blowup"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 8.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:N/A:L",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"baseScore": 7.1,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:L/SC:L/SI:N/SA:N",
"version": "4.0"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-611",
"description": "CWE-611 Improper Restriction of XML External Entity Reference",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-10-06T19:39:52.037Z",
"orgId": "c8b34d1a-69ae-45c3-88fe-f3b3d44f39b7",
"shortName": "Arista"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.arista.com/en/support/advisories-notices/security-advisory/24806-security-advisory-0190"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eCVE-2026-102155 has been fixed in the following releases:\u003c/p\u003e\u003cul\u003e\u003cli\u003e2026.2.1 and later releases\u003c/li\u003e\u003c/ul\u003e"
}
],
"value": "CVE-2026-102155 has been fixed in the following releases:\n- 2026.2.1 and later releases"
}
],
"source": {
"advisory": "Security Advisory 0190",
"defects": [
"BUG 1728574",
"BUG 1728163"
],
"discovery": "INTERNAL"
},
"title": "Security Advisory 0190",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eThere is no mitigation or workaround available for this issue.\u003c/p\u003e"
}
],
"value": "There is no mitigation or workaround available for this issue."
}
]
}
},
"cveMetadata": {
"assignerOrgId": "c8b34d1a-69ae-45c3-88fe-f3b3d44f39b7",
"assignerShortName": "Arista",
"cveId": "CVE-2026-102155",
"datePublished": "2026-10-06T19:39:52.037Z",
"dateReserved": "2026-09-28T17:41:09.358Z",
"dateUpdated": "2026-10-06T20:01:43.823Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}