    CVE-2025-41739 (GCVE-0-2025-41739)

    Vulnerability from nvd – Published: 2025-12-01 10:00 – Updated: 2026-01-07 17:09
    VLAI
    Title
    CODESYS Control - Linux/QNX SysSocket flaw
    Summary
    An unauthenticated remote attacker, who beats a race condition, can exploit a flaw in the communication servers of the CODESYS Control runtime system on Linux and QNX to trigger an out-of-bounds read via crafted socket communication, potentially causing a denial of service.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    Impacted products
    Vendor Product Version
    CODESYS CODESYS PLCHandler Affected: 3.5.21.0 , < 3.5.21.40 (semver)
    Create a notification for this product.
    CODESYS CODESYS Remote Target Visu Affected: 3.5.21.0 , < 3.5.21.40 (semver)
    Create a notification for this product.
    CODESYS CODESYS Runtime Toolkit Affected: 3.5.21.0 , < 3.5.21.40 (semver)
    Create a notification for this product.
    CODESYS CODESYS Control for BeagleBone SL Affected: 4.15.0.0 , < 4.19.0.0 (semver)
    Create a notification for this product.
    CODESYS CODESYS Control for emPC-A/iMX6 SL Affected: 4.15.0.0 , < 4.19.0.0 (semver)
    Create a notification for this product.
    CODESYS CODESYS Control for IOT2000 SL Affected: 4.15.0.0 , < 4.19.0.0 (semver)
    Create a notification for this product.
    CODESYS CODESYS Control for Linux ARM SL Affected: 4.15.0.0 , < 4.19.0.0 (semver)
    Create a notification for this product.
    CODESYS CODESYS Control for Linux SL Affected: 4.15.0.0 , < 4.19.0.0 (semver)
    Create a notification for this product.
    CODESYS CODESYS Control for PFC100 SL Affected: 4.15.0.0 , < 4.19.0.0 (semver)
    Create a notification for this product.
    CODESYS CODESYS Control for PFC200 SL Affected: 4.15.0.0 , < 4.19.0.0 (semver)
    Create a notification for this product.
    CODESYS CODESYS Control for PLCnext SL Affected: 4.15.0.0 , < 4.19.0.0 (semver)
    Create a notification for this product.
    CODESYS CODESYS Control for Raspberry Pi SL Affected: 4.15.0.0 , < 4.19.0.0 (semver)
    Create a notification for this product.
    CODESYS CODESYS Control for WAGO Touch Panels 600 SL Affected: 4.15.0.0 , < 4.19.0.0 (semver)
    Create a notification for this product.
    CODESYS CODESYS Edge Gateway for Linux Affected: 4.15.0.0 , < 4.19.0.0 (semver)
    Create a notification for this product.
    CODESYS CODESYS TargetVisu for Linux SL Affected: 4.15.0.0 , < 4.19.0.0 (semver)
    Create a notification for this product.
    CODESYS CODESYS Virtual Control SL Affected: 4.15.0.0 , < 4.19.0.0 (semver)
    Create a notification for this product.
    Credits
    ABB AG
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-41739",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-12-01T14:03:10.321003Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-01-07T17:09:52.535Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS PLCHandler",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "3.5.21.40",
                  "status": "affected",
                  "version": "3.5.21.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS Remote Target Visu",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "3.5.21.40",
                  "status": "affected",
                  "version": "3.5.21.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS Runtime Toolkit",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "3.5.21.40",
                  "status": "affected",
                  "version": "3.5.21.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS Control for BeagleBone SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.19.0.0",
                  "status": "affected",
                  "version": "4.15.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS Control for emPC-A/iMX6 SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.19.0.0",
                  "status": "affected",
                  "version": "4.15.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS Control for IOT2000 SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.19.0.0",
                  "status": "affected",
                  "version": "4.15.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS Control for Linux ARM SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.19.0.0",
                  "status": "affected",
                  "version": "4.15.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS Control for Linux SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.19.0.0",
                  "status": "affected",
                  "version": "4.15.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS Control for PFC100 SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.19.0.0",
                  "status": "affected",
                  "version": "4.15.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS Control for PFC200 SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.19.0.0",
                  "status": "affected",
                  "version": "4.15.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS Control for PLCnext SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.19.0.0",
                  "status": "affected",
                  "version": "4.15.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS Control for Raspberry Pi SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.19.0.0",
                  "status": "affected",
                  "version": "4.15.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS Control for WAGO Touch Panels 600 SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.19.0.0",
                  "status": "affected",
                  "version": "4.15.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS Edge Gateway for Linux",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.19.0.0",
                  "status": "affected",
                  "version": "4.15.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS TargetVisu for Linux SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.19.0.0",
                  "status": "affected",
                  "version": "4.15.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS Virtual Control SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.19.0.0",
                  "status": "affected",
                  "version": "4.15.0.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "ABB AG"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "An unauthenticated remote attacker, who beats a race condition, can exploit a flaw in the communication servers of the CODESYS Control runtime system on Linux and QNX to trigger an out-of-bounds read via crafted socket communication, potentially causing a denial of service.\u003cbr\u003e"
                }
              ],
              "value": "An unauthenticated remote attacker, who beats a race condition, can exploit a flaw in the communication servers of the CODESYS Control runtime system on Linux and QNX to trigger an out-of-bounds read via crafted socket communication, potentially causing a denial of service."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 5.9,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-125",
                  "description": "CWE-125 Out-of-bounds Read",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-12-01T10:00:44.373Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://certvde.com/de/advisories/VDE-2025-099"
            }
          ],
          "source": {
            "advisory": "VDE-2025-099",
            "defect": [
              "CERT@VDE#641888"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "CODESYS Control - Linux/QNX SysSocket flaw",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2025-41739",
        "datePublished": "2025-12-01T10:00:44.373Z",
        "dateReserved": "2025-04-16T11:17:48.320Z",
        "dateUpdated": "2026-01-07T17:09:52.535Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2022-31805 (GCVE-0-2022-31805)

    Vulnerability from nvd – Published: 2022-06-24 07:46 – Updated: 2024-09-16 18:55
    VLAI
    Title
    Insecure transmission of credentials
    Summary
    In the CODESYS Development System multiple components in multiple versions transmit the passwords for the communication between clients and servers unprotected.
    CWE
    • CWE-523 - Unprotected Transport of Credentials
    Assigner
    References
    Date Public
    2022-06-22 22:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T07:26:01.086Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17140\u0026token=6aa2c5c4a8b83b8b09936fefed5b0b11f9d2cc6c\u0026download="
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS Development System",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "V2.3.9.69",
                  "status": "affected",
                  "version": "V2",
                  "versionType": "custom"
                },
                {
                  "lessThan": "V3.5.18.30",
                  "status": "affected",
                  "version": "V3",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS Gateway Client",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "V2.3.9.38",
                  "status": "affected",
                  "version": "V2",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS Gateway Server",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "V2.3.9.38",
                  "status": "affected",
                  "version": "V2",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS Web server",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "V1.1.9.23",
                  "status": "affected",
                  "version": "V1",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS SP Realtime NT",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "V2.3.7.30",
                  "status": "affected",
                  "version": "V2",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS PLCWinNT",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "V2.4.7.57",
                  "status": "affected",
                  "version": "V2",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS Runtime Toolkit 32 bit full",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "V2.4.7.57",
                  "status": "affected",
                  "version": "V2",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS Edge Gateway for Windows",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "V3.5.18.30",
                  "status": "affected",
                  "version": "V3",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS HMI (SL)",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "V3.5.18.30",
                  "status": "affected",
                  "version": "V3",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS OPC DA Server SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "V3.5.18.30",
                  "status": "affected",
                  "version": "V3",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS PLCHandler",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "V3.5.18.30",
                  "status": "affected",
                  "version": "V3",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS Gateway",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "V3.5.18.30",
                  "status": "affected",
                  "version": "V3",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "datePublic": "2022-06-22T22:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eIn the CODESYS Development System multiple components in multiple versions transmit the passwords for the communication between clients and servers unprotected.\u003c/p\u003e"
                }
              ],
              "value": "In the CODESYS Development System multiple components in multiple versions transmit the passwords for the communication between clients and servers unprotected."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-523",
                  "description": "CWE-523 Unprotected Transport of Credentials",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-05-09T12:54:39.506Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17140\u0026token=6aa2c5c4a8b83b8b09936fefed5b0b11f9d2cc6c\u0026download="
            }
          ],
          "source": {
            "defect": [
              "CERT@VDE#",
              "64140"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "Insecure transmission of credentials",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "info@cert.vde.com",
              "DATE_PUBLIC": "2022-06-23T10:00:00.000Z",
              "ID": "CVE-2022-31805",
              "STATE": "PUBLIC",
              "TITLE": "Insecure transmission of credentials"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "CODESYS Development System",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "V2",
                                "version_value": "V2.3.9.69"
                              },
                              {
                                "version_affected": "\u003c",
                                "version_name": "V3",
                                "version_value": "V3.5.18.20"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "CODESYS Gateway Client",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "V2",
                                "version_value": "V2.3.9.38"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "CODESYS Gateway Server",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "V2",
                                "version_value": "V2.3.9.38"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "CODESYS Web server",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "V1",
                                "version_value": "V1.1.9.23"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "CODESYS SP Realtime NT",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "V2",
                                "version_value": "V2.3.7.30"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "CODESYS PLCWinNT",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "V2",
                                "version_value": "V2.4.7.57"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "CODESYS Runtime Toolkit 32 bit full",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "V2",
                                "version_value": "V2.4.7.57"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "CODESYS Edge Gateway for Windows",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "V3",
                                "version_value": "V3.5.18.20"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "CODESYS HMI (SL)",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "V3",
                                "version_value": "V3.5.18.20"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "CODESYS OPC DA Server SL",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "V3",
                                "version_value": "V3.5.18.20"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "CODESYS PLCHandler",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "V3",
                                "version_value": "V3.5.18.20"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "CODESYS Gateway",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "V3",
                                "version_value": "V3.5.18.20"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "CODESYS"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "In the CODESYS Development System multiple components in multiple versions transmit the passwords for the communication between clients and servers unprotected."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-523 Unprotected Transport of Credentials"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17140\u0026token=6aa2c5c4a8b83b8b09936fefed5b0b11f9d2cc6c\u0026download=",
                  "refsource": "CONFIRM",
                  "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17140\u0026token=6aa2c5c4a8b83b8b09936fefed5b0b11f9d2cc6c\u0026download="
                }
              ]
            },
            "source": {
              "defect": [
                "CERT@VDE#",
                "64140"
              ],
              "discovery": "UNKNOWN"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2022-31805",
        "datePublished": "2022-06-24T07:46:15.076Z",
        "dateReserved": "2022-05-30T00:00:00.000Z",
        "dateUpdated": "2024-09-16T18:55:26.939Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-22517 (GCVE-0-2022-22517)

    Vulnerability from nvd – Published: 2022-04-07 18:21 – Updated: 2024-09-16 22:16
    VLAI
    Title
    Communication Components in multiple CODESYS products vulnerable to communication channel disruption
    Summary
    An unauthenticated, remote attacker can disrupt existing communication channels between CODESYS products by guessing a valid channel ID and injecting packets. This results in the communication channel to be closed.
    CWE
    • CWE-334 - Small Space of Random Values
    Assigner
    References
    Impacted products
    Vendor Product Version
    CODESYS CODESYS Control RTE (SL) Affected: V3.5.18.0 , < V3.5.18.0 (custom)
    Create a notification for this product.
    CODESYS CODESYS Control RTE (for Beckhoff CX) SL Affected: V3.5.18.0 , < V3.5.18.0 (custom)
    Create a notification for this product.
    CODESYS CODESYS Control Win (SL) Affected: V3.5.18.0 , < V3.5.18.0 (custom)
    Create a notification for this product.
    CODESYS CODESYS Gateway Affected: V3.5.18.0 , < V3.5.18.0 (custom)
    Create a notification for this product.
    CODESYS CODESYS Edge Gateway for Windows Affected: V3.5.18.0 , < V3.5.18.0 (custom)
    Create a notification for this product.
    CODESYS CODESYS HMI (SL) Affected: V3.5.18.0 , < V3.5.18.0 (custom)
    Create a notification for this product.
    CODESYS CODESYS Development System V3 Affected: V3.5.18.0 , < V3.5.18.0 (custom)
    Create a notification for this product.
    CODESYS CODESYS Control Runtime System Toolkit Affected: V3.5.18.0 , < V3.5.18.0 (custom)
    Create a notification for this product.
    CODESYS CODESYS Embedded Target Visu Toolkit Affected: V3.5.18.0 , < V3.5.18.0 (custom)
    Create a notification for this product.
    CODESYS CODESYS Remote Target Visu Toolkit Affected: V3.5.18.0 , < V3.5.18.0 (custom)
    Create a notification for this product.
    CODESYS CODESYS Control for BeagleBone SL Affected: V4.5.0.0 , < V4.5.0.0 (custom)
    Create a notification for this product.
    CODESYS CODESYS Control for Beckhoff CX9020 SL Affected: V4.5.0.0 , < V4.5.0.0 (custom)
    Create a notification for this product.
    CODESYS CODESYS Control for emPC-A/iMX6 SL Affected: V4.5.0.0 , < V4.5.0.0 (custom)
    Create a notification for this product.
    CODESYS CODESYS Control for IOT2000 SL Affected: V4.5.0.0 , < V4.5.0.0 (custom)
    Create a notification for this product.
    CODESYS CODESYS Control for Linux SL Affected: V4.5.0.0 , < V4.5.0.0 (custom)
    Create a notification for this product.
    CODESYS CODESYS Control for PFC100 SL Affected: V4.5.0.0 , < V4.5.0.0 (custom)
    Create a notification for this product.
    CODESYS CODESYS Control for PFC200 SL Affected: V4.5.0.0 , < V4.5.0.0 (custom)
    Create a notification for this product.
    CODESYS CODESYS Control for PLCnext SL Affected: V4.5.0.0 , < V4.5.0.0 (custom)
    Create a notification for this product.
    CODESYS CODESYS Control for Raspberry Pi SL Affected: V4.5.0.0 , < V4.5.0.0 (custom)
    Create a notification for this product.
    CODESYS CODESYS Control for WAGO Touch Panels 600 SL Affected: V4.5.0.0 , < V4.5.0.0 (custom)
    Create a notification for this product.
    CODESYS CODESYS Edge Gateway for Linux Affected: V4.5.0.0 , < V4.5.0.0 (custom)
    Create a notification for this product.
    CODESYS CODESYS OPC DA Server SL Affected: V3.5.18.0 , < V3.5.18.0 (custom)
    Create a notification for this product.
    CODESYS CODESYS PLCHandler Affected: V3.5.18.0 , < V3.5.18.0 (custom)
    Create a notification for this product.
    Date Public
    2022-04-06 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T03:14:55.454Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17091\u0026token=c450f8bbbd838c647d102f359356386c6ea5aeca\u0026download="
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "CODESYS Control RTE (SL)",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "V3.5.18.0",
                  "status": "affected",
                  "version": "V3.5.18.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "CODESYS Control RTE (for Beckhoff CX) SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "V3.5.18.0",
                  "status": "affected",
                  "version": "V3.5.18.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "CODESYS Control Win (SL)",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "V3.5.18.0",
                  "status": "affected",
                  "version": "V3.5.18.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "CODESYS Gateway",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "V3.5.18.0",
                  "status": "affected",
                  "version": "V3.5.18.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "CODESYS Edge Gateway for Windows",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "V3.5.18.0",
                  "status": "affected",
                  "version": "V3.5.18.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "CODESYS HMI (SL)",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "V3.5.18.0",
                  "status": "affected",
                  "version": "V3.5.18.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "CODESYS Development System V3",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "V3.5.18.0",
                  "status": "affected",
                  "version": "V3.5.18.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "CODESYS Control Runtime System Toolkit",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "V3.5.18.0",
                  "status": "affected",
                  "version": "V3.5.18.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "CODESYS Embedded Target Visu Toolkit",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "V3.5.18.0",
                  "status": "affected",
                  "version": "V3.5.18.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "CODESYS Remote Target Visu Toolkit",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "V3.5.18.0",
                  "status": "affected",
                  "version": "V3.5.18.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "CODESYS Control for BeagleBone SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "V4.5.0.0",
                  "status": "affected",
                  "version": "V4.5.0.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "CODESYS Control for Beckhoff CX9020 SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "V4.5.0.0",
                  "status": "affected",
                  "version": "V4.5.0.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "CODESYS Control for emPC-A/iMX6 SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "V4.5.0.0",
                  "status": "affected",
                  "version": "V4.5.0.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "CODESYS Control for IOT2000 SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "V4.5.0.0",
                  "status": "affected",
                  "version": "V4.5.0.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "CODESYS Control for Linux SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "V4.5.0.0",
                  "status": "affected",
                  "version": "V4.5.0.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "CODESYS Control for PFC100 SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "V4.5.0.0",
                  "status": "affected",
                  "version": "V4.5.0.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "CODESYS Control for PFC200 SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "V4.5.0.0",
                  "status": "affected",
                  "version": "V4.5.0.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "CODESYS Control for PLCnext SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "V4.5.0.0",
                  "status": "affected",
                  "version": "V4.5.0.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "CODESYS Control for Raspberry Pi SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "V4.5.0.0",
                  "status": "affected",
                  "version": "V4.5.0.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "CODESYS Control for WAGO Touch Panels 600 SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "V4.5.0.0",
                  "status": "affected",
                  "version": "V4.5.0.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "CODESYS Edge Gateway for Linux",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "V4.5.0.0",
                  "status": "affected",
                  "version": "V4.5.0.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "CODESYS OPC DA Server SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "V3.5.18.0",
                  "status": "affected",
                  "version": "V3.5.18.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "CODESYS PLCHandler",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "V3.5.18.0",
                  "status": "affected",
                  "version": "V3.5.18.0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "datePublic": "2022-04-06T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "An unauthenticated, remote attacker can disrupt existing communication channels between CODESYS products by guessing a valid channel ID and injecting packets. This results in the communication channel to be closed."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-334",
                  "description": "CWE-334 Small Space of Random Values",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-04-07T18:21:19.000Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17091\u0026token=c450f8bbbd838c647d102f359356386c6ea5aeca\u0026download="
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Communication Components in multiple CODESYS products vulnerable to communication channel disruption",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "info@cert.vde.com",
              "DATE_PUBLIC": "2022-04-06T10:00:00.000Z",
              "ID": "CVE-2022-22517",
              "STATE": "PUBLIC",
              "TITLE": "Communication Components in multiple CODESYS products vulnerable to communication channel disruption"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "CODESYS Control RTE (SL)",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "V3.5.18.0",
                                "version_value": "V3.5.18.0"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "CODESYS Control RTE (for Beckhoff CX) SL",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "V3.5.18.0",
                                "version_value": "V3.5.18.0"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "CODESYS Control Win (SL)",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "V3.5.18.0",
                                "version_value": "V3.5.18.0"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "CODESYS Gateway",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "V3.5.18.0",
                                "version_value": "V3.5.18.0"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "CODESYS Edge Gateway for Windows",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "V3.5.18.0",
                                "version_value": "V3.5.18.0"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "CODESYS HMI (SL)",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "V3.5.18.0",
                                "version_value": "V3.5.18.0"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "CODESYS Development System V3",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "V3.5.18.0",
                                "version_value": "V3.5.18.0"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "CODESYS Control Runtime System Toolkit",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "V3.5.18.0",
                                "version_value": "V3.5.18.0"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "CODESYS Embedded Target Visu Toolkit",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "V3.5.18.0",
                                "version_value": "V3.5.18.0"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "CODESYS Remote Target Visu Toolkit",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "V3.5.18.0",
                                "version_value": "V3.5.18.0"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "CODESYS Control for BeagleBone SL",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "V4.5.0.0",
                                "version_value": "V4.5.0.0"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "CODESYS Control for Beckhoff CX9020 SL",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "V4.5.0.0",
                                "version_value": "V4.5.0.0"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "CODESYS Control for emPC-A/iMX6 SL",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "V4.5.0.0",
                                "version_value": "V4.5.0.0"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "CODESYS Control for IOT2000 SL",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "V4.5.0.0",
                                "version_value": "V4.5.0.0"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "CODESYS Control for Linux SL",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "V4.5.0.0",
                                "version_value": "V4.5.0.0"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "CODESYS Control for PFC100 SL",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "V4.5.0.0",
                                "version_value": "V4.5.0.0"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "CODESYS Control for PFC200 SL",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "V4.5.0.0",
                                "version_value": "V4.5.0.0"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "CODESYS Control for PLCnext SL",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "V4.5.0.0",
                                "version_value": "V4.5.0.0"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "CODESYS Control for Raspberry Pi SL",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "V4.5.0.0",
                                "version_value": "V4.5.0.0"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "CODESYS Control for WAGO Touch Panels 600 SL",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "V4.5.0.0",
                                "version_value": "V4.5.0.0"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "CODESYS Edge Gateway for Linux",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "V4.5.0.0",
                                "version_value": "V4.5.0.0"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "CODESYS OPC DA Server SL",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "V3.5.18.0",
                                "version_value": "V3.5.18.0"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "CODESYS PLCHandler",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "V3.5.18.0",
                                "version_value": "V3.5.18.0"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "CODESYS"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "An unauthenticated, remote attacker can disrupt existing communication channels between CODESYS products by guessing a valid channel ID and injecting packets. This results in the communication channel to be closed."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-334 Small Space of Random Values"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17091\u0026token=c450f8bbbd838c647d102f359356386c6ea5aeca\u0026download=",
                  "refsource": "MISC",
                  "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17091\u0026token=c450f8bbbd838c647d102f359356386c6ea5aeca\u0026download="
                }
              ]
            },
            "source": {
              "discovery": "UNKNOWN"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2022-22517",
        "datePublished": "2022-04-07T18:21:20.091Z",
        "dateReserved": "2022-01-03T00:00:00.000Z",
        "dateUpdated": "2024-09-16T22:16:04.923Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-41739 (GCVE-0-2025-41739)

    Vulnerability from cvelistv5 – Published: 2025-12-01 10:00 – Updated: 2026-01-07 17:09
    VLAI
    Title
    CODESYS Control - Linux/QNX SysSocket flaw
    Summary
    An unauthenticated remote attacker, who beats a race condition, can exploit a flaw in the communication servers of the CODESYS Control runtime system on Linux and QNX to trigger an out-of-bounds read via crafted socket communication, potentially causing a denial of service.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    Impacted products
    Vendor Product Version
    CODESYS CODESYS PLCHandler Affected: 3.5.21.0 , < 3.5.21.40 (semver)
    Create a notification for this product.
    CODESYS CODESYS Remote Target Visu Affected: 3.5.21.0 , < 3.5.21.40 (semver)
    Create a notification for this product.
    CODESYS CODESYS Runtime Toolkit Affected: 3.5.21.0 , < 3.5.21.40 (semver)
    Create a notification for this product.
    CODESYS CODESYS Control for BeagleBone SL Affected: 4.15.0.0 , < 4.19.0.0 (semver)
    Create a notification for this product.
    CODESYS CODESYS Control for emPC-A/iMX6 SL Affected: 4.15.0.0 , < 4.19.0.0 (semver)
    Create a notification for this product.
    CODESYS CODESYS Control for IOT2000 SL Affected: 4.15.0.0 , < 4.19.0.0 (semver)
    Create a notification for this product.
    CODESYS CODESYS Control for Linux ARM SL Affected: 4.15.0.0 , < 4.19.0.0 (semver)
    Create a notification for this product.
    CODESYS CODESYS Control for Linux SL Affected: 4.15.0.0 , < 4.19.0.0 (semver)
    Create a notification for this product.
    CODESYS CODESYS Control for PFC100 SL Affected: 4.15.0.0 , < 4.19.0.0 (semver)
    Create a notification for this product.
    CODESYS CODESYS Control for PFC200 SL Affected: 4.15.0.0 , < 4.19.0.0 (semver)
    Create a notification for this product.
    CODESYS CODESYS Control for PLCnext SL Affected: 4.15.0.0 , < 4.19.0.0 (semver)
    Create a notification for this product.
    CODESYS CODESYS Control for Raspberry Pi SL Affected: 4.15.0.0 , < 4.19.0.0 (semver)
    Create a notification for this product.
    CODESYS CODESYS Control for WAGO Touch Panels 600 SL Affected: 4.15.0.0 , < 4.19.0.0 (semver)
    Create a notification for this product.
    CODESYS CODESYS Edge Gateway for Linux Affected: 4.15.0.0 , < 4.19.0.0 (semver)
    Create a notification for this product.
    CODESYS CODESYS TargetVisu for Linux SL Affected: 4.15.0.0 , < 4.19.0.0 (semver)
    Create a notification for this product.
    CODESYS CODESYS Virtual Control SL Affected: 4.15.0.0 , < 4.19.0.0 (semver)
    Create a notification for this product.
    Credits
    ABB AG
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-41739",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-12-01T14:03:10.321003Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-01-07T17:09:52.535Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS PLCHandler",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "3.5.21.40",
                  "status": "affected",
                  "version": "3.5.21.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS Remote Target Visu",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "3.5.21.40",
                  "status": "affected",
                  "version": "3.5.21.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS Runtime Toolkit",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "3.5.21.40",
                  "status": "affected",
                  "version": "3.5.21.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS Control for BeagleBone SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.19.0.0",
                  "status": "affected",
                  "version": "4.15.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS Control for emPC-A/iMX6 SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.19.0.0",
                  "status": "affected",
                  "version": "4.15.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS Control for IOT2000 SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.19.0.0",
                  "status": "affected",
                  "version": "4.15.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS Control for Linux ARM SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.19.0.0",
                  "status": "affected",
                  "version": "4.15.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS Control for Linux SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.19.0.0",
                  "status": "affected",
                  "version": "4.15.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS Control for PFC100 SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.19.0.0",
                  "status": "affected",
                  "version": "4.15.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS Control for PFC200 SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.19.0.0",
                  "status": "affected",
                  "version": "4.15.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS Control for PLCnext SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.19.0.0",
                  "status": "affected",
                  "version": "4.15.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS Control for Raspberry Pi SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.19.0.0",
                  "status": "affected",
                  "version": "4.15.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS Control for WAGO Touch Panels 600 SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.19.0.0",
                  "status": "affected",
                  "version": "4.15.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS Edge Gateway for Linux",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.19.0.0",
                  "status": "affected",
                  "version": "4.15.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS TargetVisu for Linux SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.19.0.0",
                  "status": "affected",
                  "version": "4.15.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS Virtual Control SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "4.19.0.0",
                  "status": "affected",
                  "version": "4.15.0.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "ABB AG"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "An unauthenticated remote attacker, who beats a race condition, can exploit a flaw in the communication servers of the CODESYS Control runtime system on Linux and QNX to trigger an out-of-bounds read via crafted socket communication, potentially causing a denial of service.\u003cbr\u003e"
                }
              ],
              "value": "An unauthenticated remote attacker, who beats a race condition, can exploit a flaw in the communication servers of the CODESYS Control runtime system on Linux and QNX to trigger an out-of-bounds read via crafted socket communication, potentially causing a denial of service."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "HIGH",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 5.9,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-125",
                  "description": "CWE-125 Out-of-bounds Read",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-12-01T10:00:44.373Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://certvde.com/de/advisories/VDE-2025-099"
            }
          ],
          "source": {
            "advisory": "VDE-2025-099",
            "defect": [
              "CERT@VDE#641888"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "CODESYS Control - Linux/QNX SysSocket flaw",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2025-41739",
        "datePublished": "2025-12-01T10:00:44.373Z",
        "dateReserved": "2025-04-16T11:17:48.320Z",
        "dateUpdated": "2026-01-07T17:09:52.535Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2022-31805 (GCVE-0-2022-31805)

    Vulnerability from cvelistv5 – Published: 2022-06-24 07:46 – Updated: 2024-09-16 18:55
    VLAI
    Title
    Insecure transmission of credentials
    Summary
    In the CODESYS Development System multiple components in multiple versions transmit the passwords for the communication between clients and servers unprotected.
    CWE
    • CWE-523 - Unprotected Transport of Credentials
    Assigner
    References
    Date Public
    2022-06-22 22:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T07:26:01.086Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17140\u0026token=6aa2c5c4a8b83b8b09936fefed5b0b11f9d2cc6c\u0026download="
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS Development System",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "V2.3.9.69",
                  "status": "affected",
                  "version": "V2",
                  "versionType": "custom"
                },
                {
                  "lessThan": "V3.5.18.30",
                  "status": "affected",
                  "version": "V3",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS Gateway Client",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "V2.3.9.38",
                  "status": "affected",
                  "version": "V2",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS Gateway Server",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "V2.3.9.38",
                  "status": "affected",
                  "version": "V2",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS Web server",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "V1.1.9.23",
                  "status": "affected",
                  "version": "V1",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS SP Realtime NT",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "V2.3.7.30",
                  "status": "affected",
                  "version": "V2",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS PLCWinNT",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "V2.4.7.57",
                  "status": "affected",
                  "version": "V2",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS Runtime Toolkit 32 bit full",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "V2.4.7.57",
                  "status": "affected",
                  "version": "V2",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS Edge Gateway for Windows",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "V3.5.18.30",
                  "status": "affected",
                  "version": "V3",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS HMI (SL)",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "V3.5.18.30",
                  "status": "affected",
                  "version": "V3",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS OPC DA Server SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "V3.5.18.30",
                  "status": "affected",
                  "version": "V3",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS PLCHandler",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "V3.5.18.30",
                  "status": "affected",
                  "version": "V3",
                  "versionType": "custom"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CODESYS Gateway",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "V3.5.18.30",
                  "status": "affected",
                  "version": "V3",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "datePublic": "2022-06-22T22:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eIn the CODESYS Development System multiple components in multiple versions transmit the passwords for the communication between clients and servers unprotected.\u003c/p\u003e"
                }
              ],
              "value": "In the CODESYS Development System multiple components in multiple versions transmit the passwords for the communication between clients and servers unprotected."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-523",
                  "description": "CWE-523 Unprotected Transport of Credentials",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-05-09T12:54:39.506Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17140\u0026token=6aa2c5c4a8b83b8b09936fefed5b0b11f9d2cc6c\u0026download="
            }
          ],
          "source": {
            "defect": [
              "CERT@VDE#",
              "64140"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "Insecure transmission of credentials",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "info@cert.vde.com",
              "DATE_PUBLIC": "2022-06-23T10:00:00.000Z",
              "ID": "CVE-2022-31805",
              "STATE": "PUBLIC",
              "TITLE": "Insecure transmission of credentials"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "CODESYS Development System",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "V2",
                                "version_value": "V2.3.9.69"
                              },
                              {
                                "version_affected": "\u003c",
                                "version_name": "V3",
                                "version_value": "V3.5.18.20"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "CODESYS Gateway Client",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "V2",
                                "version_value": "V2.3.9.38"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "CODESYS Gateway Server",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "V2",
                                "version_value": "V2.3.9.38"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "CODESYS Web server",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "V1",
                                "version_value": "V1.1.9.23"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "CODESYS SP Realtime NT",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "V2",
                                "version_value": "V2.3.7.30"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "CODESYS PLCWinNT",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "V2",
                                "version_value": "V2.4.7.57"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "CODESYS Runtime Toolkit 32 bit full",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "V2",
                                "version_value": "V2.4.7.57"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "CODESYS Edge Gateway for Windows",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "V3",
                                "version_value": "V3.5.18.20"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "CODESYS HMI (SL)",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "V3",
                                "version_value": "V3.5.18.20"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "CODESYS OPC DA Server SL",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "V3",
                                "version_value": "V3.5.18.20"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "CODESYS PLCHandler",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "V3",
                                "version_value": "V3.5.18.20"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "CODESYS Gateway",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "V3",
                                "version_value": "V3.5.18.20"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "CODESYS"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "In the CODESYS Development System multiple components in multiple versions transmit the passwords for the communication between clients and servers unprotected."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-523 Unprotected Transport of Credentials"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17140\u0026token=6aa2c5c4a8b83b8b09936fefed5b0b11f9d2cc6c\u0026download=",
                  "refsource": "CONFIRM",
                  "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17140\u0026token=6aa2c5c4a8b83b8b09936fefed5b0b11f9d2cc6c\u0026download="
                }
              ]
            },
            "source": {
              "defect": [
                "CERT@VDE#",
                "64140"
              ],
              "discovery": "UNKNOWN"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2022-31805",
        "datePublished": "2022-06-24T07:46:15.076Z",
        "dateReserved": "2022-05-30T00:00:00.000Z",
        "dateUpdated": "2024-09-16T18:55:26.939Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-22517 (GCVE-0-2022-22517)

    Vulnerability from cvelistv5 – Published: 2022-04-07 18:21 – Updated: 2024-09-16 22:16
    VLAI
    Title
    Communication Components in multiple CODESYS products vulnerable to communication channel disruption
    Summary
    An unauthenticated, remote attacker can disrupt existing communication channels between CODESYS products by guessing a valid channel ID and injecting packets. This results in the communication channel to be closed.
    CWE
    • CWE-334 - Small Space of Random Values
    Assigner
    References
    Impacted products
    Vendor Product Version
    CODESYS CODESYS Control RTE (SL) Affected: V3.5.18.0 , < V3.5.18.0 (custom)
    Create a notification for this product.
    CODESYS CODESYS Control RTE (for Beckhoff CX) SL Affected: V3.5.18.0 , < V3.5.18.0 (custom)
    Create a notification for this product.
    CODESYS CODESYS Control Win (SL) Affected: V3.5.18.0 , < V3.5.18.0 (custom)
    Create a notification for this product.
    CODESYS CODESYS Gateway Affected: V3.5.18.0 , < V3.5.18.0 (custom)
    Create a notification for this product.
    CODESYS CODESYS Edge Gateway for Windows Affected: V3.5.18.0 , < V3.5.18.0 (custom)
    Create a notification for this product.
    CODESYS CODESYS HMI (SL) Affected: V3.5.18.0 , < V3.5.18.0 (custom)
    Create a notification for this product.
    CODESYS CODESYS Development System V3 Affected: V3.5.18.0 , < V3.5.18.0 (custom)
    Create a notification for this product.
    CODESYS CODESYS Control Runtime System Toolkit Affected: V3.5.18.0 , < V3.5.18.0 (custom)
    Create a notification for this product.
    CODESYS CODESYS Embedded Target Visu Toolkit Affected: V3.5.18.0 , < V3.5.18.0 (custom)
    Create a notification for this product.
    CODESYS CODESYS Remote Target Visu Toolkit Affected: V3.5.18.0 , < V3.5.18.0 (custom)
    Create a notification for this product.
    CODESYS CODESYS Control for BeagleBone SL Affected: V4.5.0.0 , < V4.5.0.0 (custom)
    Create a notification for this product.
    CODESYS CODESYS Control for Beckhoff CX9020 SL Affected: V4.5.0.0 , < V4.5.0.0 (custom)
    Create a notification for this product.
    CODESYS CODESYS Control for emPC-A/iMX6 SL Affected: V4.5.0.0 , < V4.5.0.0 (custom)
    Create a notification for this product.
    CODESYS CODESYS Control for IOT2000 SL Affected: V4.5.0.0 , < V4.5.0.0 (custom)
    Create a notification for this product.
    CODESYS CODESYS Control for Linux SL Affected: V4.5.0.0 , < V4.5.0.0 (custom)
    Create a notification for this product.
    CODESYS CODESYS Control for PFC100 SL Affected: V4.5.0.0 , < V4.5.0.0 (custom)
    Create a notification for this product.
    CODESYS CODESYS Control for PFC200 SL Affected: V4.5.0.0 , < V4.5.0.0 (custom)
    Create a notification for this product.
    CODESYS CODESYS Control for PLCnext SL Affected: V4.5.0.0 , < V4.5.0.0 (custom)
    Create a notification for this product.
    CODESYS CODESYS Control for Raspberry Pi SL Affected: V4.5.0.0 , < V4.5.0.0 (custom)
    Create a notification for this product.
    CODESYS CODESYS Control for WAGO Touch Panels 600 SL Affected: V4.5.0.0 , < V4.5.0.0 (custom)
    Create a notification for this product.
    CODESYS CODESYS Edge Gateway for Linux Affected: V4.5.0.0 , < V4.5.0.0 (custom)
    Create a notification for this product.
    CODESYS CODESYS OPC DA Server SL Affected: V3.5.18.0 , < V3.5.18.0 (custom)
    Create a notification for this product.
    CODESYS CODESYS PLCHandler Affected: V3.5.18.0 , < V3.5.18.0 (custom)
    Create a notification for this product.
    Date Public
    2022-04-06 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T03:14:55.454Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17091\u0026token=c450f8bbbd838c647d102f359356386c6ea5aeca\u0026download="
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "CODESYS Control RTE (SL)",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "V3.5.18.0",
                  "status": "affected",
                  "version": "V3.5.18.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "CODESYS Control RTE (for Beckhoff CX) SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "V3.5.18.0",
                  "status": "affected",
                  "version": "V3.5.18.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "CODESYS Control Win (SL)",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "V3.5.18.0",
                  "status": "affected",
                  "version": "V3.5.18.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "CODESYS Gateway",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "V3.5.18.0",
                  "status": "affected",
                  "version": "V3.5.18.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "CODESYS Edge Gateway for Windows",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "V3.5.18.0",
                  "status": "affected",
                  "version": "V3.5.18.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "CODESYS HMI (SL)",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "V3.5.18.0",
                  "status": "affected",
                  "version": "V3.5.18.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "CODESYS Development System V3",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "V3.5.18.0",
                  "status": "affected",
                  "version": "V3.5.18.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "CODESYS Control Runtime System Toolkit",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "V3.5.18.0",
                  "status": "affected",
                  "version": "V3.5.18.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "CODESYS Embedded Target Visu Toolkit",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "V3.5.18.0",
                  "status": "affected",
                  "version": "V3.5.18.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "CODESYS Remote Target Visu Toolkit",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "V3.5.18.0",
                  "status": "affected",
                  "version": "V3.5.18.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "CODESYS Control for BeagleBone SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "V4.5.0.0",
                  "status": "affected",
                  "version": "V4.5.0.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "CODESYS Control for Beckhoff CX9020 SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "V4.5.0.0",
                  "status": "affected",
                  "version": "V4.5.0.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "CODESYS Control for emPC-A/iMX6 SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "V4.5.0.0",
                  "status": "affected",
                  "version": "V4.5.0.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "CODESYS Control for IOT2000 SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "V4.5.0.0",
                  "status": "affected",
                  "version": "V4.5.0.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "CODESYS Control for Linux SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "V4.5.0.0",
                  "status": "affected",
                  "version": "V4.5.0.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "CODESYS Control for PFC100 SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "V4.5.0.0",
                  "status": "affected",
                  "version": "V4.5.0.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "CODESYS Control for PFC200 SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "V4.5.0.0",
                  "status": "affected",
                  "version": "V4.5.0.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "CODESYS Control for PLCnext SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "V4.5.0.0",
                  "status": "affected",
                  "version": "V4.5.0.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "CODESYS Control for Raspberry Pi SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "V4.5.0.0",
                  "status": "affected",
                  "version": "V4.5.0.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "CODESYS Control for WAGO Touch Panels 600 SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "V4.5.0.0",
                  "status": "affected",
                  "version": "V4.5.0.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "CODESYS Edge Gateway for Linux",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "V4.5.0.0",
                  "status": "affected",
                  "version": "V4.5.0.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "CODESYS OPC DA Server SL",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "V3.5.18.0",
                  "status": "affected",
                  "version": "V3.5.18.0",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "CODESYS PLCHandler",
              "vendor": "CODESYS",
              "versions": [
                {
                  "lessThan": "V3.5.18.0",
                  "status": "affected",
                  "version": "V3.5.18.0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "datePublic": "2022-04-06T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "An unauthenticated, remote attacker can disrupt existing communication channels between CODESYS products by guessing a valid channel ID and injecting packets. This results in the communication channel to be closed."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-334",
                  "description": "CWE-334 Small Space of Random Values",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-04-07T18:21:19.000Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17091\u0026token=c450f8bbbd838c647d102f359356386c6ea5aeca\u0026download="
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Communication Components in multiple CODESYS products vulnerable to communication channel disruption",
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "info@cert.vde.com",
              "DATE_PUBLIC": "2022-04-06T10:00:00.000Z",
              "ID": "CVE-2022-22517",
              "STATE": "PUBLIC",
              "TITLE": "Communication Components in multiple CODESYS products vulnerable to communication channel disruption"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "CODESYS Control RTE (SL)",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "V3.5.18.0",
                                "version_value": "V3.5.18.0"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "CODESYS Control RTE (for Beckhoff CX) SL",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "V3.5.18.0",
                                "version_value": "V3.5.18.0"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "CODESYS Control Win (SL)",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "V3.5.18.0",
                                "version_value": "V3.5.18.0"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "CODESYS Gateway",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "V3.5.18.0",
                                "version_value": "V3.5.18.0"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "CODESYS Edge Gateway for Windows",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "V3.5.18.0",
                                "version_value": "V3.5.18.0"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "CODESYS HMI (SL)",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "V3.5.18.0",
                                "version_value": "V3.5.18.0"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "CODESYS Development System V3",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "V3.5.18.0",
                                "version_value": "V3.5.18.0"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "CODESYS Control Runtime System Toolkit",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "V3.5.18.0",
                                "version_value": "V3.5.18.0"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "CODESYS Embedded Target Visu Toolkit",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "V3.5.18.0",
                                "version_value": "V3.5.18.0"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "CODESYS Remote Target Visu Toolkit",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "V3.5.18.0",
                                "version_value": "V3.5.18.0"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "CODESYS Control for BeagleBone SL",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "V4.5.0.0",
                                "version_value": "V4.5.0.0"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "CODESYS Control for Beckhoff CX9020 SL",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "V4.5.0.0",
                                "version_value": "V4.5.0.0"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "CODESYS Control for emPC-A/iMX6 SL",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "V4.5.0.0",
                                "version_value": "V4.5.0.0"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "CODESYS Control for IOT2000 SL",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "V4.5.0.0",
                                "version_value": "V4.5.0.0"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "CODESYS Control for Linux SL",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "V4.5.0.0",
                                "version_value": "V4.5.0.0"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "CODESYS Control for PFC100 SL",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "V4.5.0.0",
                                "version_value": "V4.5.0.0"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "CODESYS Control for PFC200 SL",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "V4.5.0.0",
                                "version_value": "V4.5.0.0"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "CODESYS Control for PLCnext SL",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "V4.5.0.0",
                                "version_value": "V4.5.0.0"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "CODESYS Control for Raspberry Pi SL",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "V4.5.0.0",
                                "version_value": "V4.5.0.0"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "CODESYS Control for WAGO Touch Panels 600 SL",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "V4.5.0.0",
                                "version_value": "V4.5.0.0"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "CODESYS Edge Gateway for Linux",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "V4.5.0.0",
                                "version_value": "V4.5.0.0"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "CODESYS OPC DA Server SL",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "V3.5.18.0",
                                "version_value": "V3.5.18.0"
                              }
                            ]
                          }
                        },
                        {
                          "product_name": "CODESYS PLCHandler",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_name": "V3.5.18.0",
                                "version_value": "V3.5.18.0"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "CODESYS"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "An unauthenticated, remote attacker can disrupt existing communication channels between CODESYS products by guessing a valid channel ID and injecting packets. This results in the communication channel to be closed."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "CWE-334 Small Space of Random Values"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17091\u0026token=c450f8bbbd838c647d102f359356386c6ea5aeca\u0026download=",
                  "refsource": "MISC",
                  "url": "https://customers.codesys.com/index.php?eID=dumpFile\u0026t=f\u0026f=17091\u0026token=c450f8bbbd838c647d102f359356386c6ea5aeca\u0026download="
                }
              ]
            },
            "source": {
              "discovery": "UNKNOWN"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2022-22517",
        "datePublished": "2022-04-07T18:21:20.091Z",
        "dateReserved": "2022-01-03T00:00:00.000Z",
        "dateUpdated": "2024-09-16T22:16:04.923Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }