4 vulnerabilities found for CNCSoft with ScreenEditor by ICS-CERT
CVE-2018-10636 (GCVE-0-2018-10636)
Vulnerability from cvelistv5 – Published: 2018-08-13 22:00 – Updated: 2024-09-16 18:13
VLAI?
Summary
CNCSoft Version 1.00.83 and prior with ScreenEditor Version 1.00.54 has multiple stack-based buffer overflow vulnerabilities that could cause the software to crash due to lacking user input validation before copying data from project files onto the stack. Which may allow an attacker to gain remote code execution with administrator privileges if exploited.
Severity ?
No CVSS data available.
CWE
- CWE-121 - STACK-BASED BUFFER OVERFLOW CWE-121
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| ICS-CERT | CNCSoft with ScreenEditor |
Affected:
CNCSoft Version 1.00.83 and prior with ScreenEditor Version 1.00.54
|
Date Public ?
2018-08-08 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T07:46:46.130Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-219-01"
},
{
"name": "105032",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/105032"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "CNCSoft with ScreenEditor",
"vendor": "ICS-CERT",
"versions": [
{
"status": "affected",
"version": "CNCSoft Version 1.00.83 and prior with ScreenEditor Version 1.00.54"
}
]
}
],
"datePublic": "2018-08-08T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "CNCSoft Version 1.00.83 and prior with ScreenEditor Version 1.00.54 has multiple stack-based buffer overflow vulnerabilities that could cause the software to crash due to lacking user input validation before copying data from project files onto the stack. Which may allow an attacker to gain remote code execution with administrator privileges if exploited."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "STACK-BASED BUFFER OVERFLOW CWE-121",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-08-14T09:57:01.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-219-01"
},
{
"name": "105032",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/105032"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"DATE_PUBLIC": "2018-08-08T00:00:00",
"ID": "CVE-2018-10636",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "CNCSoft with ScreenEditor",
"version": {
"version_data": [
{
"version_value": "CNCSoft Version 1.00.83 and prior with ScreenEditor Version 1.00.54"
}
]
}
}
]
},
"vendor_name": "ICS-CERT"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "CNCSoft Version 1.00.83 and prior with ScreenEditor Version 1.00.54 has multiple stack-based buffer overflow vulnerabilities that could cause the software to crash due to lacking user input validation before copying data from project files onto the stack. Which may allow an attacker to gain remote code execution with administrator privileges if exploited."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "STACK-BASED BUFFER OVERFLOW CWE-121"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-219-01",
"refsource": "MISC",
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-219-01"
},
{
"name": "105032",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/105032"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2018-10636",
"datePublished": "2018-08-13T22:00:00.000Z",
"dateReserved": "2018-05-01T00:00:00.000Z",
"dateUpdated": "2024-09-16T18:13:08.613Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-10598 (GCVE-0-2018-10598)
Vulnerability from cvelistv5 – Published: 2018-08-13 22:00 – Updated: 2024-09-17 02:47
VLAI?
Summary
CNCSoft Version 1.00.83 and prior with ScreenEditor Version 1.00.54 has two out-of-bounds read vulnerabilities could cause the software to crash due to lacking user input validation for processing project files. Which may allow an attacker to gain remote code execution with administrator privileges if exploited.
Severity ?
No CVSS data available.
CWE
- CWE-125 - OUT-OF-BOUNDS READ CWE-125
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| ICS-CERT | CNCSoft with ScreenEditor |
Affected:
CNCSoft Version 1.00.83 and prior with ScreenEditor Version 1.00.54
|
Date Public ?
2018-08-08 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T07:39:08.522Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-219-01"
},
{
"name": "105032",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/105032"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "CNCSoft with ScreenEditor",
"vendor": "ICS-CERT",
"versions": [
{
"status": "affected",
"version": "CNCSoft Version 1.00.83 and prior with ScreenEditor Version 1.00.54"
}
]
}
],
"datePublic": "2018-08-08T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "CNCSoft Version 1.00.83 and prior with ScreenEditor Version 1.00.54 has two out-of-bounds read vulnerabilities could cause the software to crash due to lacking user input validation for processing project files. Which may allow an attacker to gain remote code execution with administrator privileges if exploited."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "OUT-OF-BOUNDS READ CWE-125",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-08-14T09:57:01.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-219-01"
},
{
"name": "105032",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/105032"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"DATE_PUBLIC": "2018-08-08T00:00:00",
"ID": "CVE-2018-10598",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "CNCSoft with ScreenEditor",
"version": {
"version_data": [
{
"version_value": "CNCSoft Version 1.00.83 and prior with ScreenEditor Version 1.00.54"
}
]
}
}
]
},
"vendor_name": "ICS-CERT"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "CNCSoft Version 1.00.83 and prior with ScreenEditor Version 1.00.54 has two out-of-bounds read vulnerabilities could cause the software to crash due to lacking user input validation for processing project files. Which may allow an attacker to gain remote code execution with administrator privileges if exploited."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "OUT-OF-BOUNDS READ CWE-125"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-219-01",
"refsource": "MISC",
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-219-01"
},
{
"name": "105032",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/105032"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2018-10598",
"datePublished": "2018-08-13T22:00:00.000Z",
"dateReserved": "2018-05-01T00:00:00.000Z",
"dateUpdated": "2024-09-17T02:47:50.846Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-10636 (GCVE-0-2018-10636)
Vulnerability from nvd – Published: 2018-08-13 22:00 – Updated: 2024-09-16 18:13
VLAI?
Summary
CNCSoft Version 1.00.83 and prior with ScreenEditor Version 1.00.54 has multiple stack-based buffer overflow vulnerabilities that could cause the software to crash due to lacking user input validation before copying data from project files onto the stack. Which may allow an attacker to gain remote code execution with administrator privileges if exploited.
Severity ?
No CVSS data available.
CWE
- CWE-121 - STACK-BASED BUFFER OVERFLOW CWE-121
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| ICS-CERT | CNCSoft with ScreenEditor |
Affected:
CNCSoft Version 1.00.83 and prior with ScreenEditor Version 1.00.54
|
Date Public ?
2018-08-08 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T07:46:46.130Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-219-01"
},
{
"name": "105032",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/105032"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "CNCSoft with ScreenEditor",
"vendor": "ICS-CERT",
"versions": [
{
"status": "affected",
"version": "CNCSoft Version 1.00.83 and prior with ScreenEditor Version 1.00.54"
}
]
}
],
"datePublic": "2018-08-08T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "CNCSoft Version 1.00.83 and prior with ScreenEditor Version 1.00.54 has multiple stack-based buffer overflow vulnerabilities that could cause the software to crash due to lacking user input validation before copying data from project files onto the stack. Which may allow an attacker to gain remote code execution with administrator privileges if exploited."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "STACK-BASED BUFFER OVERFLOW CWE-121",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-08-14T09:57:01.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-219-01"
},
{
"name": "105032",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/105032"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"DATE_PUBLIC": "2018-08-08T00:00:00",
"ID": "CVE-2018-10636",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "CNCSoft with ScreenEditor",
"version": {
"version_data": [
{
"version_value": "CNCSoft Version 1.00.83 and prior with ScreenEditor Version 1.00.54"
}
]
}
}
]
},
"vendor_name": "ICS-CERT"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "CNCSoft Version 1.00.83 and prior with ScreenEditor Version 1.00.54 has multiple stack-based buffer overflow vulnerabilities that could cause the software to crash due to lacking user input validation before copying data from project files onto the stack. Which may allow an attacker to gain remote code execution with administrator privileges if exploited."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "STACK-BASED BUFFER OVERFLOW CWE-121"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-219-01",
"refsource": "MISC",
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-219-01"
},
{
"name": "105032",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/105032"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2018-10636",
"datePublished": "2018-08-13T22:00:00.000Z",
"dateReserved": "2018-05-01T00:00:00.000Z",
"dateUpdated": "2024-09-16T18:13:08.613Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-10598 (GCVE-0-2018-10598)
Vulnerability from nvd – Published: 2018-08-13 22:00 – Updated: 2024-09-17 02:47
VLAI?
Summary
CNCSoft Version 1.00.83 and prior with ScreenEditor Version 1.00.54 has two out-of-bounds read vulnerabilities could cause the software to crash due to lacking user input validation for processing project files. Which may allow an attacker to gain remote code execution with administrator privileges if exploited.
Severity ?
No CVSS data available.
CWE
- CWE-125 - OUT-OF-BOUNDS READ CWE-125
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| ICS-CERT | CNCSoft with ScreenEditor |
Affected:
CNCSoft Version 1.00.83 and prior with ScreenEditor Version 1.00.54
|
Date Public ?
2018-08-08 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T07:39:08.522Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-219-01"
},
{
"name": "105032",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/105032"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "CNCSoft with ScreenEditor",
"vendor": "ICS-CERT",
"versions": [
{
"status": "affected",
"version": "CNCSoft Version 1.00.83 and prior with ScreenEditor Version 1.00.54"
}
]
}
],
"datePublic": "2018-08-08T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "CNCSoft Version 1.00.83 and prior with ScreenEditor Version 1.00.54 has two out-of-bounds read vulnerabilities could cause the software to crash due to lacking user input validation for processing project files. Which may allow an attacker to gain remote code execution with administrator privileges if exploited."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "OUT-OF-BOUNDS READ CWE-125",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-08-14T09:57:01.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-219-01"
},
{
"name": "105032",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/105032"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"DATE_PUBLIC": "2018-08-08T00:00:00",
"ID": "CVE-2018-10598",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "CNCSoft with ScreenEditor",
"version": {
"version_data": [
{
"version_value": "CNCSoft Version 1.00.83 and prior with ScreenEditor Version 1.00.54"
}
]
}
}
]
},
"vendor_name": "ICS-CERT"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "CNCSoft Version 1.00.83 and prior with ScreenEditor Version 1.00.54 has two out-of-bounds read vulnerabilities could cause the software to crash due to lacking user input validation for processing project files. Which may allow an attacker to gain remote code execution with administrator privileges if exploited."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "OUT-OF-BOUNDS READ CWE-125"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-219-01",
"refsource": "MISC",
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-219-01"
},
{
"name": "105032",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/105032"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2018-10598",
"datePublished": "2018-08-13T22:00:00.000Z",
"dateReserved": "2018-05-01T00:00:00.000Z",
"dateUpdated": "2024-09-17T02:47:50.846Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}