Search

Find a vulnerability

Search criteria

    9 vulnerabilities found for CF-N1-S by Comfast

    CVE-2026-78050 (GCVE-0-2026-78050)

    Vulnerability from nvd – Published: 2026-08-22 23:15 – Updated: 2026-08-22 23:15
    VLAI
    Title
    Comfast CF-N1-S Web Management mbox-config sub_41AD7C stack-based overflow
    Summary
    A vulnerability was found in Comfast CF-N1-S 2.6.0.1. The affected element is the function sub_41AD7C of the file /cgi-bin/mbox-config?method=SET&section=ntp_timezone of the component Web Management. The manipulation of the argument timestr/ntp_client_enabled results in stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been made public and could be used.
    CWE
    References
    URL Tags
    https://vuldb.com/vuln/394291 vdb-entrytechnical-description
    https://vuldb.com/vuln/394291/cti signaturepermissions-required
    https://vuldb.com/cve/CVE-2026-78050 third-party-advisory
    https://vuldb.com/submit/881293 third-party-advisory
    https://github.com/AdminSafe/CVE/issues/9 exploitissue-tracking
    Impacted products
    Vendor Product Version
    Comfast CF-N1-S Affected: 2.6.0.1
        cpe:2.3:a:comfast:cf-n1-s:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:a:comfast:cf-n1-s:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "Web Management"
              ],
              "product": "CF-N1-S",
              "vendor": "Comfast",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.6.0.1"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "010hex (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was found in Comfast CF-N1-S 2.6.0.1. The affected element is the function sub_41AD7C of the file /cgi-bin/mbox-config?method=SET\u0026section=ntp_timezone of the component Web Management. The manipulation of the argument timestr/ntp_client_enabled results in stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been made public and could be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 9.4,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 9.9,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 9.9,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-08-22T23:15:11.186Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-394291 | Comfast CF-N1-S Web Management mbox-config sub_41AD7C stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/394291"
            },
            {
              "name": "VDB-394291 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/394291/cti"
            },
            {
              "name": "CVE-2026-78050 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-78050"
            },
            {
              "name": "Submit #881293 | Comfast CF-N1-S V2.6.0.1 Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/881293"
            },
            {
              "tags": [
                "exploit",
                "issue-tracking"
              ],
              "url": "https://github.com/AdminSafe/CVE/issues/9"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-08-22T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-08-22T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-08-22T10:13:46.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Comfast CF-N1-S Web Management mbox-config sub_41AD7C stack-based overflow",
          "x_generator": [
            "VulDB PVTS v202608"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-78050",
        "datePublished": "2026-08-22T23:15:11.186Z",
        "dateReserved": "2026-08-22T08:08:41.778Z",
        "dateUpdated": "2026-08-22T23:15:11.186Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-77683 (GCVE-0-2026-77683)

    Vulnerability from nvd – Published: 2026-08-21 10:15 – Updated: 2026-08-21 13:52
    VLAI
    Title
    Comfast CF-N1-S mbox-config system command injection
    Summary
    A security flaw has been discovered in Comfast CF-N1-S 2.6.0.1. Affected by this issue is the function system of the file /cgi-bin/mbox-config?method=SET&section=ntp_timezone. The manipulation of the argument timestr results in command injection. The attack can be launched remotely. The exploit has been released to the public and may be used for attacks.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-08-21 13:51 UTC
    CWE
    References
    URL Tags
    https://vuldb.com/vuln/394033 vdb-entrytechnical-description
    https://vuldb.com/vuln/394033/cti signaturepermissions-required
    https://vuldb.com/cve/CVE-2026-77683 third-party-advisory
    https://vuldb.com/submit/881058 third-party-advisory
    https://github.com/AdminSafe/CVE/issues/8 exploitissue-tracking
    Impacted products
    Vendor Product Version
    Comfast CF-N1-S Affected: 2.6.0.1
        cpe:2.3:a:comfast:cf-n1-s:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-77683",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-08-21T13:51:46.509367Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-08-21T13:52:02.069Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:a:comfast:cf-n1-s:*:*:*:*:*:*:*:*"
              ],
              "product": "CF-N1-S",
              "vendor": "Comfast",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.6.0.1"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "010hex (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A security flaw has been discovered in Comfast CF-N1-S 2.6.0.1. Affected by this issue is the function system of the file /cgi-bin/mbox-config?method=SET\u0026section=ntp_timezone. The manipulation of the argument timestr results in command injection. The attack can be launched remotely. The exploit has been released to the public and may be used for attacks."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 9.4,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 9.9,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 9.9,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-77",
                  "description": "Command Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-74",
                  "description": "Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-08-21T10:15:08.099Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-394033 | Comfast CF-N1-S mbox-config system command injection",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/394033"
            },
            {
              "name": "VDB-394033 | CTI Indicators (IOB, IOC, TTP, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/394033/cti"
            },
            {
              "name": "CVE-2026-77683 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-77683"
            },
            {
              "name": "Submit #881058 | Comfast CF-N1-S V2.6.0.1 Command Injection",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/881058"
            },
            {
              "tags": [
                "exploit",
                "issue-tracking"
              ],
              "url": "https://github.com/AdminSafe/CVE/issues/8"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-08-21T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-08-21T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-08-21T07:36:56.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Comfast CF-N1-S mbox-config system command injection",
          "x_generator": [
            "VulDB PVTS v202608"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-77683",
        "datePublished": "2026-08-21T10:15:08.099Z",
        "dateReserved": "2026-08-21T05:31:50.847Z",
        "dateUpdated": "2026-08-21T13:52:02.069Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-77148 (GCVE-0-2026-77148)

    Vulnerability from nvd – Published: 2026-08-20 18:15 – Updated: 2026-08-20 19:46
    VLAI
    Title
    Comfast CF-N1-S Web Management mbox-config sub_44B50C stack-based overflow
    Summary
    A vulnerability was found in Comfast CF-N1-S 2.6.0.1. This impacts the function sub_44B50C of the file /cgi-bin/mbox-config?method=SET&section=ptest_channel of the component Web Management. The manipulation results in stack-based buffer overflow. The attack can be launched remotely. The exploit has been made public and could be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-08-20 19:46 UTC
    CWE
    References
    URL Tags
    https://vuldb.com/vuln/393733 vdb-entrytechnical-description
    https://vuldb.com/vuln/393733/cti signaturepermissions-required
    https://vuldb.com/cve/CVE-2026-77148 third-party-advisory
    https://vuldb.com/submit/880910 third-party-advisory
    https://github.com/AdminSafe/CVE/issues/7 exploitissue-tracking
    Impacted products
    Vendor Product Version
    Comfast CF-N1-S Affected: 2.6.0.1
        cpe:2.3:a:comfast:cf-n1-s:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-77148",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-08-20T19:46:38.830086Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-08-20T19:46:50.485Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:a:comfast:cf-n1-s:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "Web Management"
              ],
              "product": "CF-N1-S",
              "vendor": "Comfast",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.6.0.1"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "010hex (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was found in Comfast CF-N1-S 2.6.0.1. This impacts the function sub_44B50C of the file /cgi-bin/mbox-config?method=SET\u0026section=ptest_channel of the component Web Management. The manipulation results in stack-based buffer overflow. The attack can be launched remotely. The exploit has been made public and could be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 9.4,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 9.9,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 9.9,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-08-20T18:15:08.812Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-393733 | Comfast CF-N1-S Web Management mbox-config sub_44B50C stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/393733"
            },
            {
              "name": "VDB-393733 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/393733/cti"
            },
            {
              "name": "CVE-2026-77148 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-77148"
            },
            {
              "name": "Submit #880910 | Comfast CF-N1-S V2.6.0.1 Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/880910"
            },
            {
              "tags": [
                "exploit",
                "issue-tracking"
              ],
              "url": "https://github.com/AdminSafe/CVE/issues/7"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-08-20T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-08-20T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-08-20T15:54:41.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Comfast CF-N1-S Web Management mbox-config sub_44B50C stack-based overflow",
          "x_generator": [
            "VulDB PVTS v202608"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-77148",
        "datePublished": "2026-08-20T18:15:08.812Z",
        "dateReserved": "2026-08-20T13:49:33.053Z",
        "dateUpdated": "2026-08-20T19:46:50.485Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-77022 (GCVE-0-2026-77022)

    Vulnerability from nvd – Published: 2026-08-20 16:45 – Updated: 2026-08-21 21:47
    VLAI
    Title
    Comfast CF-N1-S SSID Configuration mbox-config sub_44B438 stack-based overflow
    Summary
    A security flaw has been discovered in Comfast CF-N1-S 2.6.0.1. Affected by this issue is the function sub_44B438 of the file /cgi-bin/mbox-config?method=SET&section=ptest_ssid of the component SSID Configuration. The manipulation of the argument ssid results in stack-based buffer overflow. The attack can be executed remotely. The exploit has been released to the public and may be used for attacks.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-08-21 21:39 UTC
    CWE
    References
    URL Tags
    https://vuldb.com/vuln/393637 vdb-entrytechnical-description
    https://vuldb.com/vuln/393637/cti signaturepermissions-required
    https://vuldb.com/cve/CVE-2026-77022 third-party-advisory
    https://vuldb.com/submit/880599 third-party-advisory
    https://github.com/AdminSafe/CVE/issues/5 exploitissue-tracking
    Impacted products
    Vendor Product Version
    Comfast CF-N1-S Affected: 2.6.0.1
        cpe:2.3:a:comfast:cf-n1-s:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-77022",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-08-21T21:39:08.073669Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-08-21T21:47:09.947Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:a:comfast:cf-n1-s:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "SSID Configuration"
              ],
              "product": "CF-N1-S",
              "vendor": "Comfast",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.6.0.1"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "010hex (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A security flaw has been discovered in Comfast CF-N1-S 2.6.0.1. Affected by this issue is the function sub_44B438 of the file /cgi-bin/mbox-config?method=SET\u0026section=ptest_ssid of the component SSID Configuration. The manipulation of the argument ssid results in stack-based buffer overflow. The attack can be executed remotely. The exploit has been released to the public and may be used for attacks."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 9.4,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 9.9,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 9.9,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-08-20T16:45:07.012Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-393637 | Comfast CF-N1-S SSID Configuration mbox-config sub_44B438 stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/393637"
            },
            {
              "name": "VDB-393637 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/393637/cti"
            },
            {
              "name": "CVE-2026-77022 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-77022"
            },
            {
              "name": "Submit #880599 | Comfast CF-N1-S V2 V2.6.0.1 Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/880599"
            },
            {
              "tags": [
                "exploit",
                "issue-tracking"
              ],
              "url": "https://github.com/AdminSafe/CVE/issues/5"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-08-20T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-08-20T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-08-20T10:38:52.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Comfast CF-N1-S SSID Configuration mbox-config sub_44B438 stack-based overflow",
          "x_generator": [
            "VulDB PVTS v202608"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-77022",
        "datePublished": "2026-08-20T16:45:07.012Z",
        "dateReserved": "2026-08-20T08:33:45.881Z",
        "dateUpdated": "2026-08-21T21:47:09.947Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-77004 (GCVE-0-2026-77004)

    Vulnerability from nvd – Published: 2026-08-20 16:00 – Updated: 2026-08-20 17:10
    VLAI
    Title
    Comfast CF-N1-S mbox-config sprintf command injection
    Summary
    A flaw has been found in Comfast CF-N1-S 2.6.0.1. This impacts the function sprintf of the file /cgi-bin/mbox-config?method=SET&section=ptest_sn. Executing a manipulation of the argument sn can lead to command injection. The attack can be launched remotely. The exploit has been published and may be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-08-20 17:09 UTC
    CWE
    References
    URL Tags
    https://vuldb.com/vuln/393623 vdb-entrytechnical-description
    https://vuldb.com/vuln/393623/cti signaturepermissions-required
    https://vuldb.com/cve/CVE-2026-77004 third-party-advisory
    https://vuldb.com/submit/880584 third-party-advisory
    https://github.com/lxiansheng488-bit/-/blob/main/… exploit
    Impacted products
    Vendor Product Version
    Comfast CF-N1-S Affected: 2.6.0.1
        cpe:2.3:a:comfast:cf-n1-s:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-77004",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-08-20T17:09:59.711548Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-08-20T17:10:13.138Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:a:comfast:cf-n1-s:*:*:*:*:*:*:*:*"
              ],
              "product": "CF-N1-S",
              "vendor": "Comfast",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.6.0.1"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "577488768 (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A flaw has been found in Comfast CF-N1-S 2.6.0.1. This impacts the function sprintf of the file /cgi-bin/mbox-config?method=SET\u0026section=ptest_sn. Executing a manipulation of the argument sn can lead to command injection. The attack can be launched remotely. The exploit has been published and may be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:L/SI:L/SA:L/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 7.4,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:L/I:L/A:L/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 7.4,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:C/C:L/I:L/A:L/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 6.5,
                "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-77",
                  "description": "Command Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-74",
                  "description": "Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-08-20T16:00:09.986Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-393623 | Comfast CF-N1-S mbox-config sprintf command injection",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/393623"
            },
            {
              "name": "VDB-393623 | CTI Indicators (IOB, IOC, TTP, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/393623/cti"
            },
            {
              "name": "CVE-2026-77004 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-77004"
            },
            {
              "name": "Submit #880584 | Comfast  CF-N1-S V2 V2.6.0.1 Command Injection",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/880584"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/lxiansheng488-bit/-/blob/main/%E5%8E%82%E5%95%86comefast%20%20CF-N1-S%20V2.pdf"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-08-20T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-08-20T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-08-20T09:37:05.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Comfast CF-N1-S mbox-config sprintf command injection",
          "x_generator": [
            "VulDB PVTS v202608"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-77004",
        "datePublished": "2026-08-20T16:00:09.986Z",
        "dateReserved": "2026-08-20T07:31:59.383Z",
        "dateUpdated": "2026-08-20T17:10:13.138Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-76008 (GCVE-0-2026-76008)

    Vulnerability from nvd – Published: 2026-08-19 02:30 – Updated: 2026-08-19 15:47
    VLAI
    Title
    Comfast CF-N1-S URI Parameter Parsing mbox-config get_para_from_uri stack-based overflow
    Summary
    A flaw has been found in Comfast CF-N1-S 2.6.0.1. This affects the function get_para_from_uri of the file /cgi-bin/mbox-config of the component URI Parameter Parsing. This manipulation of the argument width/height causes stack-based buffer overflow. The attack can be initiated remotely.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-08-19 15:46 UTC
    CWE
    References
    URL Tags
    https://vuldb.com/vuln/391922 vdb-entrytechnical-description
    https://vuldb.com/vuln/391922/cti signaturepermissions-required
    https://vuldb.com/cve/CVE-2026-76008 third-party-advisory
    https://vuldb.com/submit/878007 third-party-advisory
    https://github.com/1ChaoRen1/IOT_3 related
    Impacted products
    Vendor Product Version
    Comfast CF-N1-S Affected: 2.6.0.1
        cpe:2.3:a:comfast:cf-n1-s:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-76008",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-08-19T15:46:49.442564Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-08-19T15:47:03.268Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:a:comfast:cf-n1-s:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "URI Parameter Parsing"
              ],
              "product": "CF-N1-S",
              "vendor": "Comfast",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.6.0.1"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "ChaoRenChaoJiWuDi (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A flaw has been found in Comfast CF-N1-S 2.6.0.1. This affects the function get_para_from_uri of the file /cgi-bin/mbox-config of the component URI Parameter Parsing. This manipulation of the argument width/height causes stack-based buffer overflow. The attack can be initiated remotely."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:X/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 10,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:X/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 10,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C/E:ND/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-08-19T02:30:09.048Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-391922 | Comfast CF-N1-S URI Parameter Parsing mbox-config get_para_from_uri stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/391922"
            },
            {
              "name": "VDB-391922 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/391922/cti"
            },
            {
              "name": "CVE-2026-76008 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-76008"
            },
            {
              "name": "Submit #878007 | Comfast CF-N1-S  V2.6.0.1 Stack-based Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/878007"
            },
            {
              "tags": [
                "related"
              ],
              "url": "https://github.com/1ChaoRen1/IOT_3"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-08-18T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-08-18T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-08-18T20:58:56.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Comfast CF-N1-S URI Parameter Parsing mbox-config get_para_from_uri stack-based overflow",
          "x_generator": [
            "VulDB PVTS v202608"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-76008",
        "datePublished": "2026-08-19T02:30:09.048Z",
        "dateReserved": "2026-08-18T18:53:46.811Z",
        "dateUpdated": "2026-08-19T15:47:03.268Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-75094 (GCVE-0-2026-75094)

    Vulnerability from nvd – Published: 2026-08-18 01:45 – Updated: 2026-08-18 14:15
    VLAI
    Title
    COMFAST CF-N1-S CGI mbox-config sub_44B438 os command injection
    Summary
    A flaw has been found in COMFAST CF-N1-S 2.6.0.1. This impacts the function sub_44B438 of the file /cgi-bin/mbox-config?method=SET&section=ptest_ssid of the component CGI Interface. This manipulation of the argument ssid causes os command injection. Remote exploitation of the attack is possible. The exploit has been published and may be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-08-18 14:15 UTC
    CWE
    References
    URL Tags
    https://vuldb.com/vuln/391346 vdb-entrytechnical-description
    https://vuldb.com/vuln/391346/cti signaturepermissions-required
    https://vuldb.com/cve/CVE-2026-75094 third-party-advisory
    https://vuldb.com/submit/877482 third-party-advisory
    https://github.com/1ChaoRen1/IOT_1 exploit
    Impacted products
    Vendor Product Version
    COMFAST CF-N1-S Affected: 2.6.0.1
        cpe:2.3:a:comfast:cf-n1-s:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-75094",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-08-18T14:15:27.681863Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-08-18T14:15:42.370Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:a:comfast:cf-n1-s:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "CGI Interface"
              ],
              "product": "CF-N1-S",
              "vendor": "COMFAST",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.6.0.1"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "ChaoRenChaoJiWuDi (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A flaw has been found in COMFAST CF-N1-S 2.6.0.1. This impacts the function sub_44B438 of the file /cgi-bin/mbox-config?method=SET\u0026section=ptest_ssid of the component CGI Interface. This manipulation of the argument ssid causes os command injection. Remote exploitation of the attack is possible. The exploit has been published and may be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 9.4,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 9.1,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 9.1,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 8.3,
                "vectorString": "AV:N/AC:L/Au:M/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "OS Command Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-77",
                  "description": "Command Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-08-18T01:45:09.700Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-391346 | COMFAST CF-N1-S CGI mbox-config sub_44B438 os command injection",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/391346"
            },
            {
              "name": "VDB-391346 | CTI Indicators (IOB, IOC, TTP, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/391346/cti"
            },
            {
              "name": "CVE-2026-75094 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-75094"
            },
            {
              "name": "Submit #877482 | Comfast CF-N1-S V2.6.0.1 Command Injection",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/877482"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/1ChaoRen1/IOT_1"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-08-17T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-08-17T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-08-17T18:51:56.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "COMFAST CF-N1-S CGI mbox-config sub_44B438 os command injection",
          "x_generator": [
            "VulDB PVTS v202608"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-75094",
        "datePublished": "2026-08-18T01:45:09.700Z",
        "dateReserved": "2026-08-17T16:46:50.116Z",
        "dateUpdated": "2026-08-18T14:15:42.370Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-19976 (GCVE-0-2026-19976)

    Vulnerability from nvd – Published: 2026-08-17 02:45 – Updated: 2026-08-17 15:52
    VLAI
    Title
    COMFAST CF-N1-S mbox-config sub_44A968 command injection
    Summary
    A security vulnerability has been detected in COMFAST CF-N1-S 2.6.0.1. Impacted is the function sub_44A968 of the file /cgi-bin/mbox-config?method=SET&section=ptest_macaddress. Such manipulation of the argument macaddress leads to command injection. The attack may be launched remotely. The exploit has been disclosed publicly and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-08-17 15:48 UTC
    CWE
    References
    URL Tags
    https://vuldb.com/vuln/391155 vdb-entrytechnical-description
    https://vuldb.com/vuln/391155/cti signaturepermissions-required
    https://vuldb.com/cve/CVE-2026-19976 third-party-advisory
    https://vuldb.com/submit/873821 third-party-advisory
    https://github.com/1ChaoRen1/IOT/blob/main/CF-N1-… exploit
    Impacted products
    Vendor Product Version
    COMFAST CF-N1-S Affected: 2.6.0.1
        cpe:2.3:a:comfast:cf-n1-s:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-19976",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-08-17T15:48:36.944339Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-08-17T15:52:54.951Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:a:comfast:cf-n1-s:*:*:*:*:*:*:*:*"
              ],
              "product": "CF-N1-S",
              "vendor": "COMFAST",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.6.0.1"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "ChaoRenChaoJiWuDi (VulDB User)"
            },
            {
              "lang": "en",
              "type": "coordinator",
              "value": "VulDB CNA Team"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A security vulnerability has been detected in COMFAST CF-N1-S 2.6.0.1. Impacted is the function sub_44A968 of the file /cgi-bin/mbox-config?method=SET\u0026section=ptest_macaddress. Such manipulation of the argument macaddress leads to command injection. The attack may be launched remotely. The exploit has been disclosed publicly and may be used. The vendor was contacted early about this disclosure but did not respond in any way."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 5.1,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:L/VI:L/VA:L/SC:L/SI:L/SA:L/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 6.6,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:L/I:L/A:L/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 6.6,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:C/C:L/I:L/A:L/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 5.8,
                "vectorString": "AV:N/AC:L/Au:M/C:P/I:P/A:P/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-77",
                  "description": "Command Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-74",
                  "description": "Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-08-17T02:45:11.135Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-391155 | COMFAST CF-N1-S mbox-config sub_44A968 command injection",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/391155"
            },
            {
              "name": "VDB-391155 | CTI Indicators (IOB, IOC, TTP, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/391155/cti"
            },
            {
              "name": "CVE-2026-19976 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-19976"
            },
            {
              "name": "Submit #873821 | Comfast CF-N1-S  V2.6.0.1 Command Injection",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/873821"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/1ChaoRen1/IOT/blob/main/CF-N1-S-V2.6.0.1%20.pdf"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-08-16T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-08-16T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-08-16T14:04:53.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "COMFAST CF-N1-S mbox-config sub_44A968 command injection",
          "x_generator": [
            "VulDB PVTS v202608"
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-19976",
        "datePublished": "2026-08-17T02:45:11.135Z",
        "dateReserved": "2026-08-16T11:59:46.359Z",
        "dateUpdated": "2026-08-17T15:52:54.951Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-6799 (GCVE-0-2026-6799)

    Vulnerability from nvd – Published: 2026-04-21 21:00 – Updated: 2026-04-22 12:19
    VLAI
    Title
    Comfast CF-N1-S Endpoint mbox-config command injection
    Summary
    A security flaw has been discovered in Comfast CF-N1-S 2.6.0.1. Affected by this issue is some unknown functionality of the file /cgi-bin/mbox-config?method=SET&section=ping_config of the component Endpoint. Performing a manipulation of the argument destination results in command injection. The attack can be initiated remotely. The exploit has been released to the public and may be used for attacks. The vendor was contacted early about this disclosure but did not respond in any way.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-04-22 12:18 UTC
    CWE
    References
    URL Tags
    https://vuldb.com/vuln/358492 vdb-entrytechnical-description
    https://vuldb.com/vuln/358492/cti signaturepermissions-required
    https://vuldb.com/submit/795203 third-party-advisory
    https://github.com/Blackhole23-Lab/-/blob/main/Co… exploit
    Impacted products
    Vendor Product Version
    Comfast CF-N1-S Affected: 2.6.0.1
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-6799",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-04-22T12:18:58.139576Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-04-22T12:19:06.935Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "modules": [
                "Endpoint"
              ],
              "product": "CF-N1-S",
              "vendor": "Comfast",
              "versions": [
                {
                  "status": "affected",
                  "version": "2.6.0.1"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "xxyNB (VulDB User)"
            },
            {
              "lang": "en",
              "type": "coordinator",
              "value": "VulDB CNA Team"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A security flaw has been discovered in Comfast CF-N1-S 2.6.0.1. Affected by this issue is some unknown functionality of the file /cgi-bin/mbox-config?method=SET\u0026section=ping_config of the component Endpoint. Performing a manipulation of the argument destination results in command injection. The attack can be initiated remotely. The exploit has been released to the public and may be used for attacks. The vendor was contacted early about this disclosure but did not respond in any way."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 6.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 6.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 6.5,
                "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-77",
                  "description": "Command Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-74",
                  "description": "Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-04-21T21:00:21.078Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-358492 | Comfast CF-N1-S Endpoint mbox-config command injection",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/358492"
            },
            {
              "name": "VDB-358492 | CTI Indicators (IOB, IOC, TTP, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/358492/cti"
            },
            {
              "name": "Submit #795203 | Comfast CF-N1-S V2.6.0.1 Authenticated Command Injection",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/795203"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/Blackhole23-Lab/-/blob/main/Comfast-CF-N1-S-Router-VUDB.md"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-04-21T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-04-21T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-04-21T16:48:47.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Comfast CF-N1-S Endpoint mbox-config command injection"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-6799",
        "datePublished": "2026-04-21T21:00:21.078Z",
        "dateReserved": "2026-04-21T14:43:41.714Z",
        "dateUpdated": "2026-04-22T12:19:06.935Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }