GCVE Workshop - 22 September 2026 (14:00-18:00), Luxembourg Before The Vulnopticon Conference - Registration
Search

Find a vulnerability

Search criteria

    2 vulnerabilities found for BME690 SensorAPI (C) by Bosch Sensortec

    CVE-2026-42806 (GCVE-0-2026-42806)

    Vulnerability from nvd – Published: 2026-09-10 09:04 – Updated: 2026-09-10 15:00
    VLAI
    Summary
    An out-of-bounds read vulnerability was discovered in the Bosch BME690 SensorAPI (C-driver) in version v1.0.3 and prior, specifically within the field data parsing logic in read_all_field_data (bme69x.c). The driver prefetches heater configuration registers into a contiguous 30-byte stack buffer (set_val) mapping IDAC, RES_HEAT, and GAS_WAIT tables. When parsing sensor field data, the gas_index is extracted using a 4-bit mask (0..15) but lacks boundary verification against the valid range (0..9). An attacker or a compromised peripheral mimicking a sensor on the I2C/SPI bus could return a payload with a gas index value of 10 or higher. This causes the driver to perform an out-of-bounds array access (set_val[20 + gas_index]), reading up to 6 bytes past the stack buffer. The leaked out-of-bounds byte is then written into the public gas_wait field, which may lead to measurement corruption or leak adjacent stack memory when telemetered or logged.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-10 15:00 UTC
    CWE
    References
    Impacted products
    Vendor Product Version
    Bosch Sensortec BME690 SensorAPI (C) Affected: 1.0.1 , ≤ 1.0.3 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-42806",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-10T15:00:33.822497Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-10T15:00:50.874Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "BME690 SensorAPI (C)",
              "vendor": "Bosch Sensortec",
              "versions": [
                {
                  "lessThanOrEqual": "1.0.3",
                  "status": "affected",
                  "version": "1.0.1",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "An out-of-bounds read vulnerability was discovered in the Bosch BME690 SensorAPI (C-driver) in version v1.0.3 and prior, specifically within the field data parsing logic in read_all_field_data (bme69x.c).\r\n\r\nThe driver prefetches heater configuration registers into a contiguous 30-byte stack buffer (set_val) mapping IDAC, RES_HEAT, and GAS_WAIT tables.\r\n\r\nWhen parsing sensor field data, the gas_index is extracted using a 4-bit mask (0..15) but lacks boundary verification against the valid range (0..9).\r\n\r\nAn attacker or a compromised peripheral mimicking a sensor on the I2C/SPI bus could return a payload with a gas index value of 10 or higher.\r\n\r\nThis causes the driver to perform an out-of-bounds array access (set_val[20 + gas_index]), reading up to 6 bytes past the stack buffer.\r\n\r\nThe leaked out-of-bounds byte is then written into the public gas_wait field, which may lead to measurement corruption or leak adjacent stack memory when telemetered or logged."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "PHYSICAL",
                "availabilityImpact": "LOW",
                "baseScore": 4.3,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-125",
                  "description": "CWE-125 Out-of-bounds Read",
                  "lang": "en-US"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-10T09:04:44.607Z",
            "orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
            "shortName": "bosch"
          },
          "references": [
            {
              "name": "https://psirt.bosch.com/security-advisories/BOSCH-SA-223618.html",
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-223618.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
        "assignerShortName": "bosch",
        "cveId": "CVE-2026-42806",
        "datePublished": "2026-09-10T09:04:44.607Z",
        "dateReserved": "2026-04-30T08:03:11.875Z",
        "dateUpdated": "2026-09-10T15:00:50.874Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-42806 (GCVE-0-2026-42806)

    Vulnerability from cvelistv5 – Published: 2026-09-10 09:04 – Updated: 2026-09-10 15:00
    VLAI
    Summary
    An out-of-bounds read vulnerability was discovered in the Bosch BME690 SensorAPI (C-driver) in version v1.0.3 and prior, specifically within the field data parsing logic in read_all_field_data (bme69x.c). The driver prefetches heater configuration registers into a contiguous 30-byte stack buffer (set_val) mapping IDAC, RES_HEAT, and GAS_WAIT tables. When parsing sensor field data, the gas_index is extracted using a 4-bit mask (0..15) but lacks boundary verification against the valid range (0..9). An attacker or a compromised peripheral mimicking a sensor on the I2C/SPI bus could return a payload with a gas index value of 10 or higher. This causes the driver to perform an out-of-bounds array access (set_val[20 + gas_index]), reading up to 6 bytes past the stack buffer. The leaked out-of-bounds byte is then written into the public gas_wait field, which may lead to measurement corruption or leak adjacent stack memory when telemetered or logged.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-10 15:00 UTC
    CWE
    References
    Impacted products
    Vendor Product Version
    Bosch Sensortec BME690 SensorAPI (C) Affected: 1.0.1 , ≤ 1.0.3 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-42806",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-10T15:00:33.822497Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-10T15:00:50.874Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "BME690 SensorAPI (C)",
              "vendor": "Bosch Sensortec",
              "versions": [
                {
                  "lessThanOrEqual": "1.0.3",
                  "status": "affected",
                  "version": "1.0.1",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "An out-of-bounds read vulnerability was discovered in the Bosch BME690 SensorAPI (C-driver) in version v1.0.3 and prior, specifically within the field data parsing logic in read_all_field_data (bme69x.c).\r\n\r\nThe driver prefetches heater configuration registers into a contiguous 30-byte stack buffer (set_val) mapping IDAC, RES_HEAT, and GAS_WAIT tables.\r\n\r\nWhen parsing sensor field data, the gas_index is extracted using a 4-bit mask (0..15) but lacks boundary verification against the valid range (0..9).\r\n\r\nAn attacker or a compromised peripheral mimicking a sensor on the I2C/SPI bus could return a payload with a gas index value of 10 or higher.\r\n\r\nThis causes the driver to perform an out-of-bounds array access (set_val[20 + gas_index]), reading up to 6 bytes past the stack buffer.\r\n\r\nThe leaked out-of-bounds byte is then written into the public gas_wait field, which may lead to measurement corruption or leak adjacent stack memory when telemetered or logged."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "PHYSICAL",
                "availabilityImpact": "LOW",
                "baseScore": 4.3,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-125",
                  "description": "CWE-125 Out-of-bounds Read",
                  "lang": "en-US"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-10T09:04:44.607Z",
            "orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
            "shortName": "bosch"
          },
          "references": [
            {
              "name": "https://psirt.bosch.com/security-advisories/BOSCH-SA-223618.html",
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-223618.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
        "assignerShortName": "bosch",
        "cveId": "CVE-2026-42806",
        "datePublished": "2026-09-10T09:04:44.607Z",
        "dateReserved": "2026-04-30T08:03:11.875Z",
        "dateUpdated": "2026-09-10T15:00:50.874Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }