Search criteria
2 vulnerabilities found for AC7 1200M by Tenda
CVE-2025-1819 (GCVE-0-2025-1819)
Vulnerability from nvd – Published: 2025-03-02 16:31 – Updated: 2025-03-03 20:10
VLAI?
Title
Tenda AC7 1200M telnet TendaTelnet os command injection
Summary
A vulnerability, which was classified as critical, was found in Tenda AC7 1200M 15.03.06.44. Affected is the function TendaTelnet of the file /goform/telnet. The manipulation of the argument lan_ip leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
Severity ?
6.3 (Medium)
6.3 (Medium)
Assigner
References
| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
Credits
Raining101 (VulDB User)
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-1819",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-03T17:15:11.891552Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-03-03T20:10:12.362Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "AC7 1200M",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "15.03.06.44"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "Raining101 (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability, which was classified as critical, was found in Tenda AC7 1200M 15.03.06.44. Affected is the function TendaTelnet of the file /goform/telnet. The manipulation of the argument lan_ip leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used."
},
{
"lang": "de",
"value": "Es wurde eine Schwachstelle in Tenda AC7 1200M 15.03.06.44 gefunden. Sie wurde als kritisch eingestuft. Es geht dabei um die Funktion TendaTelnet der Datei /goform/telnet. Durch die Manipulation des Arguments lan_ip mit unbekannten Daten kann eine os command injection-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 6.5,
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "OS Command Injection",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-77",
"description": "Command Injection",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-03-02T16:31:05.928Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-298092 | Tenda AC7 1200M telnet TendaTelnet os command injection",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.298092"
},
{
"name": "VDB-298092 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.298092"
},
{
"name": "Submit #504429 | Tenda AC7 1200M large household 11ac dual-band wireless router V15.03.06.44 Command injection",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.504429"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/Raining-101/IOT_cve/blob/main/Tenda%20a7%20V15.03.06.44%20Command%20injection.md"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2025-03-01T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2025-03-01T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2025-03-01T15:37:10.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda AC7 1200M telnet TendaTelnet os command injection"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2025-1819",
"datePublished": "2025-03-02T16:31:05.928Z",
"dateReserved": "2025-03-01T14:32:01.743Z",
"dateUpdated": "2025-03-03T20:10:12.362Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-1819 (GCVE-0-2025-1819)
Vulnerability from cvelistv5 – Published: 2025-03-02 16:31 – Updated: 2025-03-03 20:10
VLAI?
Title
Tenda AC7 1200M telnet TendaTelnet os command injection
Summary
A vulnerability, which was classified as critical, was found in Tenda AC7 1200M 15.03.06.44. Affected is the function TendaTelnet of the file /goform/telnet. The manipulation of the argument lan_ip leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
Severity ?
6.3 (Medium)
6.3 (Medium)
Assigner
References
| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
Credits
Raining101 (VulDB User)
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-1819",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-03-03T17:15:11.891552Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-03-03T20:10:12.362Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "AC7 1200M",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "15.03.06.44"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "Raining101 (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability, which was classified as critical, was found in Tenda AC7 1200M 15.03.06.44. Affected is the function TendaTelnet of the file /goform/telnet. The manipulation of the argument lan_ip leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used."
},
{
"lang": "de",
"value": "Es wurde eine Schwachstelle in Tenda AC7 1200M 15.03.06.44 gefunden. Sie wurde als kritisch eingestuft. Es geht dabei um die Funktion TendaTelnet der Datei /goform/telnet. Durch die Manipulation des Arguments lan_ip mit unbekannten Daten kann eine os command injection-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 6.5,
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "OS Command Injection",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-77",
"description": "Command Injection",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-03-02T16:31:05.928Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-298092 | Tenda AC7 1200M telnet TendaTelnet os command injection",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.298092"
},
{
"name": "VDB-298092 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.298092"
},
{
"name": "Submit #504429 | Tenda AC7 1200M large household 11ac dual-band wireless router V15.03.06.44 Command injection",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.504429"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/Raining-101/IOT_cve/blob/main/Tenda%20a7%20V15.03.06.44%20Command%20injection.md"
},
{
"tags": [
"product"
],
"url": "https://www.tenda.com.cn/"
}
],
"timeline": [
{
"lang": "en",
"time": "2025-03-01T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2025-03-01T01:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2025-03-01T15:37:10.000Z",
"value": "VulDB entry last update"
}
],
"title": "Tenda AC7 1200M telnet TendaTelnet os command injection"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2025-1819",
"datePublished": "2025-03-02T16:31:05.928Z",
"dateReserved": "2025-03-01T14:32:01.743Z",
"dateUpdated": "2025-03-03T20:10:12.362Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}