Search criteria

2 vulnerabilities found for 7kg9501-0aa31-0aa1_firmware by siemens

CVE-2021-44165 (GCVE-0-2021-44165)

Vulnerability from nvd – Published: 2021-12-14 12:06 – Updated: 2024-08-04 04:17
VLAI?
Summary
A vulnerability has been identified in POWER METER SICAM Q100 (All versions < V2.41), POWER METER SICAM Q100 (All versions < V2.41), POWER METER SICAM Q100 (All versions < V2.41), POWER METER SICAM Q100 (All versions < V2.41). The affected firmware contains a buffer overflow vulnerability in the web application that could allow a remote attacker with engineer or admin priviliges to potentially perform remote code execution.
Severity ?
No CVSS data available.
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
Impacted products
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T04:17:24.538Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-496292.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "POWER METER SICAM Q100",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.41"
            }
          ]
        },
        {
          "product": "POWER METER SICAM Q100",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.41"
            }
          ]
        },
        {
          "product": "POWER METER SICAM Q100",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.41"
            }
          ]
        },
        {
          "product": "POWER METER SICAM Q100",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.41"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in POWER METER SICAM Q100 (All versions \u003c V2.41), POWER METER SICAM Q100 (All versions \u003c V2.41), POWER METER SICAM Q100 (All versions \u003c V2.41), POWER METER SICAM Q100 (All versions \u003c V2.41). The affected firmware contains a buffer overflow vulnerability in the web application that could allow a remote attacker with engineer or admin priviliges to potentially perform remote code execution."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121: Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-12-14T12:06:52",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-496292.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2021-44165",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "POWER METER SICAM Q100",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2.41"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "POWER METER SICAM Q100",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2.41"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "POWER METER SICAM Q100",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2.41"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "POWER METER SICAM Q100",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2.41"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in POWER METER SICAM Q100 (All versions \u003c V2.41), POWER METER SICAM Q100 (All versions \u003c V2.41), POWER METER SICAM Q100 (All versions \u003c V2.41), POWER METER SICAM Q100 (All versions \u003c V2.41). The affected firmware contains a buffer overflow vulnerability in the web application that could allow a remote attacker with engineer or admin priviliges to potentially perform remote code execution."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-121: Stack-based Buffer Overflow"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-496292.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-496292.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-44165",
    "datePublished": "2021-12-14T12:06:52",
    "dateReserved": "2021-11-23T00:00:00",
    "dateUpdated": "2024-08-04T04:17:24.538Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-44165 (GCVE-0-2021-44165)

Vulnerability from cvelistv5 – Published: 2021-12-14 12:06 – Updated: 2024-08-04 04:17
VLAI?
Summary
A vulnerability has been identified in POWER METER SICAM Q100 (All versions < V2.41), POWER METER SICAM Q100 (All versions < V2.41), POWER METER SICAM Q100 (All versions < V2.41), POWER METER SICAM Q100 (All versions < V2.41). The affected firmware contains a buffer overflow vulnerability in the web application that could allow a remote attacker with engineer or admin priviliges to potentially perform remote code execution.
Severity ?
No CVSS data available.
CWE
  • CWE-121 - Stack-based Buffer Overflow
Assigner
References
Impacted products
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T04:17:24.538Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-496292.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "POWER METER SICAM Q100",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.41"
            }
          ]
        },
        {
          "product": "POWER METER SICAM Q100",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.41"
            }
          ]
        },
        {
          "product": "POWER METER SICAM Q100",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.41"
            }
          ]
        },
        {
          "product": "POWER METER SICAM Q100",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.41"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in POWER METER SICAM Q100 (All versions \u003c V2.41), POWER METER SICAM Q100 (All versions \u003c V2.41), POWER METER SICAM Q100 (All versions \u003c V2.41), POWER METER SICAM Q100 (All versions \u003c V2.41). The affected firmware contains a buffer overflow vulnerability in the web application that could allow a remote attacker with engineer or admin priviliges to potentially perform remote code execution."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121: Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-12-14T12:06:52",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-496292.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2021-44165",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "POWER METER SICAM Q100",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2.41"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "POWER METER SICAM Q100",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2.41"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "POWER METER SICAM Q100",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2.41"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "POWER METER SICAM Q100",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2.41"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in POWER METER SICAM Q100 (All versions \u003c V2.41), POWER METER SICAM Q100 (All versions \u003c V2.41), POWER METER SICAM Q100 (All versions \u003c V2.41), POWER METER SICAM Q100 (All versions \u003c V2.41). The affected firmware contains a buffer overflow vulnerability in the web application that could allow a remote attacker with engineer or admin priviliges to potentially perform remote code execution."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-121: Stack-based Buffer Overflow"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-496292.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-496292.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-44165",
    "datePublished": "2021-12-14T12:06:52",
    "dateReserved": "2021-11-23T00:00:00",
    "dateUpdated": "2024-08-04T04:17:24.538Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}