Search criteria

2 vulnerabilities found for 6gk5626-2gs00-2ac2_firmware by siemens

CVE-2022-46144 (GCVE-0-2022-46144)

Vulnerability from nvd – Published: 2022-12-13 00:00 – Updated: 2025-04-21 13:42
VLAI?
Summary
A vulnerability has been identified in SCALANCE SC622-2C (6GK5622-2GS00-2AC2) (All versions < V2.3), SCALANCE SC622-2C (6GK5622-2GS00-2AC2) (All versions >= V2.3 < V3.0), SCALANCE SC626-2C (6GK5626-2GS00-2AC2) (All versions < V2.3), SCALANCE SC626-2C (6GK5626-2GS00-2AC2) (All versions >= V2.3 < V3.0), SCALANCE SC632-2C (6GK5632-2GS00-2AC2) (All versions < V2.3), SCALANCE SC632-2C (6GK5632-2GS00-2AC2) (All versions >= V2.3 < V3.0), SCALANCE SC636-2C (6GK5636-2GS00-2AC2) (All versions < V2.3), SCALANCE SC636-2C (6GK5636-2GS00-2AC2) (All versions >= V2.3 < V3.0), SCALANCE SC642-2C (6GK5642-2GS00-2AC2) (All versions < V2.3), SCALANCE SC642-2C (6GK5642-2GS00-2AC2) (All versions >= V2.3 < V3.0), SCALANCE SC646-2C (6GK5646-2GS00-2AC2) (All versions < V2.3), SCALANCE SC646-2C (6GK5646-2GS00-2AC2) (All versions >= V2.3 < V3.0), SCALANCE WAM763-1 (6GK5763-1AL00-7DA0) (All versions < V2.0.0), SCALANCE WAM766-1 (6GK5766-1GE00-7DA0) (All versions < V2.0.0), SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0) (All versions < V2.0.0), SCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0) (All versions < V2.0.0), SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0) (All versions < V2.0.0), SCALANCE WUM763-1 (6GK5763-1AL00-3AA0) (All versions < V2.0.0), SCALANCE WUM763-1 (6GK5763-1AL00-3DA0) (All versions < V2.0.0), SCALANCE WUM766-1 (6GK5766-1GE00-3DA0) (All versions < V2.0.0), SCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0) (All versions < V2.0.0). Affected devices do not properly process CLI commands after a user forcefully quitted the SSH connection. This could allow an authenticated attacker to make the CLI via SSH or serial interface irresponsive.
CWE
  • CWE-664 - Improper Control of a Resource Through its Lifetime
Assigner
Impacted products
Vendor Product Version
Siemens SCALANCE SC622-2C Affected: 0 , < V2.3 (custom)
Create a notification for this product.
    Siemens SCALANCE SC622-2C Affected: V2.3 , < V3.0 (custom)
Create a notification for this product.
    Siemens SCALANCE SC626-2C Affected: 0 , < V2.3 (custom)
Create a notification for this product.
    Siemens SCALANCE SC626-2C Affected: V2.3 , < V3.0 (custom)
Create a notification for this product.
    Siemens SCALANCE SC632-2C Affected: 0 , < V2.3 (custom)
Create a notification for this product.
    Siemens SCALANCE SC632-2C Affected: V2.3 , < V3.0 (custom)
Create a notification for this product.
    Siemens SCALANCE SC636-2C Affected: 0 , < V2.3 (custom)
Create a notification for this product.
    Siemens SCALANCE SC636-2C Affected: V2.3 , < V3.0 (custom)
Create a notification for this product.
    Siemens SCALANCE SC642-2C Affected: 0 , < V2.3 (custom)
Create a notification for this product.
    Siemens SCALANCE SC642-2C Affected: V2.3 , < V3.0 (custom)
Create a notification for this product.
    Siemens SCALANCE SC646-2C Affected: 0 , < V2.3 (custom)
Create a notification for this product.
    Siemens SCALANCE SC646-2C Affected: V2.3 , < V3.0 (custom)
Create a notification for this product.
    Siemens SCALANCE WAM763-1 Affected: 0 , < V2.0.0 (custom)
Create a notification for this product.
    Siemens SCALANCE WAM766-1 Affected: 0 , < V2.0.0 (custom)
Create a notification for this product.
    Siemens SCALANCE WAM766-1 (US) Affected: 0 , < V2.0.0 (custom)
Create a notification for this product.
    Siemens SCALANCE WAM766-1 EEC Affected: 0 , < V2.0.0 (custom)
Create a notification for this product.
    Siemens SCALANCE WAM766-1 EEC (US) Affected: 0 , < V2.0.0 (custom)
Create a notification for this product.
    Siemens SCALANCE WUM763-1 Affected: 0 , < V2.0.0 (custom)
Create a notification for this product.
    Siemens SCALANCE WUM763-1 Affected: 0 , < V2.0.0 (custom)
Create a notification for this product.
    Siemens SCALANCE WUM766-1 Affected: 0 , < V2.0.0 (custom)
Create a notification for this product.
    Siemens SCALANCE WUM766-1 (USA) Affected: 0 , < V2.0.0 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T14:24:03.262Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-413565.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-413565.html"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-690517.html"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-46144",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-18T15:14:39.836171Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-21T13:42:58.124Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC622-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC622-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0",
              "status": "affected",
              "version": "V2.3",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC626-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC626-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0",
              "status": "affected",
              "version": "V2.3",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC632-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC632-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0",
              "status": "affected",
              "version": "V2.3",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC636-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC636-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0",
              "status": "affected",
              "version": "V2.3",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC642-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC642-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0",
              "status": "affected",
              "version": "V2.3",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC646-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC646-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0",
              "status": "affected",
              "version": "V2.3",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM763-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM766-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM766-1 (US)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM766-1 EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM766-1 EEC (US)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WUM763-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WUM763-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WUM766-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WUM766-1 (USA)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SCALANCE SC622-2C (6GK5622-2GS00-2AC2) (All versions \u003c V2.3), SCALANCE SC622-2C (6GK5622-2GS00-2AC2) (All versions \u003e= V2.3 \u003c V3.0), SCALANCE SC626-2C (6GK5626-2GS00-2AC2) (All versions \u003c V2.3), SCALANCE SC626-2C (6GK5626-2GS00-2AC2) (All versions \u003e= V2.3 \u003c V3.0), SCALANCE SC632-2C (6GK5632-2GS00-2AC2) (All versions \u003c V2.3), SCALANCE SC632-2C (6GK5632-2GS00-2AC2) (All versions \u003e= V2.3 \u003c V3.0), SCALANCE SC636-2C (6GK5636-2GS00-2AC2) (All versions \u003c V2.3), SCALANCE SC636-2C (6GK5636-2GS00-2AC2) (All versions \u003e= V2.3 \u003c V3.0), SCALANCE SC642-2C (6GK5642-2GS00-2AC2) (All versions \u003c V2.3), SCALANCE SC642-2C (6GK5642-2GS00-2AC2) (All versions \u003e= V2.3 \u003c V3.0), SCALANCE SC646-2C (6GK5646-2GS00-2AC2) (All versions \u003c V2.3), SCALANCE SC646-2C (6GK5646-2GS00-2AC2) (All versions \u003e= V2.3 \u003c V3.0), SCALANCE WAM763-1 (6GK5763-1AL00-7DA0) (All versions \u003c V2.0.0), SCALANCE WAM766-1 (6GK5766-1GE00-7DA0) (All versions \u003c V2.0.0), SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0) (All versions \u003c V2.0.0), SCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0) (All versions \u003c V2.0.0), SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0) (All versions \u003c V2.0.0), SCALANCE WUM763-1 (6GK5763-1AL00-3AA0) (All versions \u003c V2.0.0), SCALANCE WUM763-1 (6GK5763-1AL00-3DA0) (All versions \u003c V2.0.0), SCALANCE WUM766-1 (6GK5766-1GE00-3DA0) (All versions \u003c V2.0.0), SCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0) (All versions \u003c V2.0.0). Affected devices do not properly process CLI commands after a user forcefully quitted the SSH connection. This could allow an authenticated attacker to make the CLI via SSH or serial  interface irresponsive."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 7.1,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-664",
              "description": "CWE-664: Improper Control of a Resource Through its Lifetime",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-01-14T10:27:12.880Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-413565.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-413565.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-690517.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-46144",
    "datePublished": "2022-12-13T00:00:00.000Z",
    "dateReserved": "2022-11-28T00:00:00.000Z",
    "dateUpdated": "2025-04-21T13:42:58.124Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-46144 (GCVE-0-2022-46144)

Vulnerability from cvelistv5 – Published: 2022-12-13 00:00 – Updated: 2025-04-21 13:42
VLAI?
Summary
A vulnerability has been identified in SCALANCE SC622-2C (6GK5622-2GS00-2AC2) (All versions < V2.3), SCALANCE SC622-2C (6GK5622-2GS00-2AC2) (All versions >= V2.3 < V3.0), SCALANCE SC626-2C (6GK5626-2GS00-2AC2) (All versions < V2.3), SCALANCE SC626-2C (6GK5626-2GS00-2AC2) (All versions >= V2.3 < V3.0), SCALANCE SC632-2C (6GK5632-2GS00-2AC2) (All versions < V2.3), SCALANCE SC632-2C (6GK5632-2GS00-2AC2) (All versions >= V2.3 < V3.0), SCALANCE SC636-2C (6GK5636-2GS00-2AC2) (All versions < V2.3), SCALANCE SC636-2C (6GK5636-2GS00-2AC2) (All versions >= V2.3 < V3.0), SCALANCE SC642-2C (6GK5642-2GS00-2AC2) (All versions < V2.3), SCALANCE SC642-2C (6GK5642-2GS00-2AC2) (All versions >= V2.3 < V3.0), SCALANCE SC646-2C (6GK5646-2GS00-2AC2) (All versions < V2.3), SCALANCE SC646-2C (6GK5646-2GS00-2AC2) (All versions >= V2.3 < V3.0), SCALANCE WAM763-1 (6GK5763-1AL00-7DA0) (All versions < V2.0.0), SCALANCE WAM766-1 (6GK5766-1GE00-7DA0) (All versions < V2.0.0), SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0) (All versions < V2.0.0), SCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0) (All versions < V2.0.0), SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0) (All versions < V2.0.0), SCALANCE WUM763-1 (6GK5763-1AL00-3AA0) (All versions < V2.0.0), SCALANCE WUM763-1 (6GK5763-1AL00-3DA0) (All versions < V2.0.0), SCALANCE WUM766-1 (6GK5766-1GE00-3DA0) (All versions < V2.0.0), SCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0) (All versions < V2.0.0). Affected devices do not properly process CLI commands after a user forcefully quitted the SSH connection. This could allow an authenticated attacker to make the CLI via SSH or serial interface irresponsive.
CWE
  • CWE-664 - Improper Control of a Resource Through its Lifetime
Assigner
Impacted products
Vendor Product Version
Siemens SCALANCE SC622-2C Affected: 0 , < V2.3 (custom)
Create a notification for this product.
    Siemens SCALANCE SC622-2C Affected: V2.3 , < V3.0 (custom)
Create a notification for this product.
    Siemens SCALANCE SC626-2C Affected: 0 , < V2.3 (custom)
Create a notification for this product.
    Siemens SCALANCE SC626-2C Affected: V2.3 , < V3.0 (custom)
Create a notification for this product.
    Siemens SCALANCE SC632-2C Affected: 0 , < V2.3 (custom)
Create a notification for this product.
    Siemens SCALANCE SC632-2C Affected: V2.3 , < V3.0 (custom)
Create a notification for this product.
    Siemens SCALANCE SC636-2C Affected: 0 , < V2.3 (custom)
Create a notification for this product.
    Siemens SCALANCE SC636-2C Affected: V2.3 , < V3.0 (custom)
Create a notification for this product.
    Siemens SCALANCE SC642-2C Affected: 0 , < V2.3 (custom)
Create a notification for this product.
    Siemens SCALANCE SC642-2C Affected: V2.3 , < V3.0 (custom)
Create a notification for this product.
    Siemens SCALANCE SC646-2C Affected: 0 , < V2.3 (custom)
Create a notification for this product.
    Siemens SCALANCE SC646-2C Affected: V2.3 , < V3.0 (custom)
Create a notification for this product.
    Siemens SCALANCE WAM763-1 Affected: 0 , < V2.0.0 (custom)
Create a notification for this product.
    Siemens SCALANCE WAM766-1 Affected: 0 , < V2.0.0 (custom)
Create a notification for this product.
    Siemens SCALANCE WAM766-1 (US) Affected: 0 , < V2.0.0 (custom)
Create a notification for this product.
    Siemens SCALANCE WAM766-1 EEC Affected: 0 , < V2.0.0 (custom)
Create a notification for this product.
    Siemens SCALANCE WAM766-1 EEC (US) Affected: 0 , < V2.0.0 (custom)
Create a notification for this product.
    Siemens SCALANCE WUM763-1 Affected: 0 , < V2.0.0 (custom)
Create a notification for this product.
    Siemens SCALANCE WUM763-1 Affected: 0 , < V2.0.0 (custom)
Create a notification for this product.
    Siemens SCALANCE WUM766-1 Affected: 0 , < V2.0.0 (custom)
Create a notification for this product.
    Siemens SCALANCE WUM766-1 (USA) Affected: 0 , < V2.0.0 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T14:24:03.262Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-413565.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-413565.html"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-690517.html"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-46144",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-18T15:14:39.836171Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-21T13:42:58.124Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC622-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC622-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0",
              "status": "affected",
              "version": "V2.3",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC626-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC626-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0",
              "status": "affected",
              "version": "V2.3",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC632-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC632-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0",
              "status": "affected",
              "version": "V2.3",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC636-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC636-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0",
              "status": "affected",
              "version": "V2.3",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC642-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC642-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0",
              "status": "affected",
              "version": "V2.3",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC646-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE SC646-2C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.0",
              "status": "affected",
              "version": "V2.3",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM763-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM766-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM766-1 (US)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM766-1 EEC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WAM766-1 EEC (US)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WUM763-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WUM763-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WUM766-1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE WUM766-1 (USA)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V2.0.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SCALANCE SC622-2C (6GK5622-2GS00-2AC2) (All versions \u003c V2.3), SCALANCE SC622-2C (6GK5622-2GS00-2AC2) (All versions \u003e= V2.3 \u003c V3.0), SCALANCE SC626-2C (6GK5626-2GS00-2AC2) (All versions \u003c V2.3), SCALANCE SC626-2C (6GK5626-2GS00-2AC2) (All versions \u003e= V2.3 \u003c V3.0), SCALANCE SC632-2C (6GK5632-2GS00-2AC2) (All versions \u003c V2.3), SCALANCE SC632-2C (6GK5632-2GS00-2AC2) (All versions \u003e= V2.3 \u003c V3.0), SCALANCE SC636-2C (6GK5636-2GS00-2AC2) (All versions \u003c V2.3), SCALANCE SC636-2C (6GK5636-2GS00-2AC2) (All versions \u003e= V2.3 \u003c V3.0), SCALANCE SC642-2C (6GK5642-2GS00-2AC2) (All versions \u003c V2.3), SCALANCE SC642-2C (6GK5642-2GS00-2AC2) (All versions \u003e= V2.3 \u003c V3.0), SCALANCE SC646-2C (6GK5646-2GS00-2AC2) (All versions \u003c V2.3), SCALANCE SC646-2C (6GK5646-2GS00-2AC2) (All versions \u003e= V2.3 \u003c V3.0), SCALANCE WAM763-1 (6GK5763-1AL00-7DA0) (All versions \u003c V2.0.0), SCALANCE WAM766-1 (6GK5766-1GE00-7DA0) (All versions \u003c V2.0.0), SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0) (All versions \u003c V2.0.0), SCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0) (All versions \u003c V2.0.0), SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0) (All versions \u003c V2.0.0), SCALANCE WUM763-1 (6GK5763-1AL00-3AA0) (All versions \u003c V2.0.0), SCALANCE WUM763-1 (6GK5763-1AL00-3DA0) (All versions \u003c V2.0.0), SCALANCE WUM766-1 (6GK5766-1GE00-3DA0) (All versions \u003c V2.0.0), SCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0) (All versions \u003c V2.0.0). Affected devices do not properly process CLI commands after a user forcefully quitted the SSH connection. This could allow an authenticated attacker to make the CLI via SSH or serial  interface irresponsive."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 7.1,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-664",
              "description": "CWE-664: Improper Control of a Resource Through its Lifetime",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-01-14T10:27:12.880Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-413565.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-413565.html"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-690517.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-46144",
    "datePublished": "2022-12-13T00:00:00.000Z",
    "dateReserved": "2022-11-28T00:00:00.000Z",
    "dateUpdated": "2025-04-21T13:42:58.124Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}