Search
Find a vulnerability
Search criteria
2 vulnerabilities found for 6ag1052-2cc08-7ba1_firmware by siemens
CVE-2022-42784 (GCVE-0-2022-42784)
Vulnerability from nvd – Published: 2023-12-12 10:02 – Updated: 2024-10-08 08:39
VLAI
Summary
A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA1) (All versions >= V8.3), LOGO! 12/24RCEo (6ED1052-2MD08-0BA1) (All versions >= V8.3), LOGO! 230RCE (6ED1052-1FB08-0BA1) (All versions >= V8.3), LOGO! 230RCEo (6ED1052-2FB08-0BA1) (All versions >= V8.3), LOGO! 24CE (6ED1052-1CC08-0BA1) (All versions >= V8.3), LOGO! 24CEo (6ED1052-2CC08-0BA1) (All versions >= V8.3), LOGO! 24RCE (6ED1052-1HB08-0BA1) (All versions >= V8.3), LOGO! 24RCEo (6ED1052-2HB08-0BA1) (All versions >= V8.3), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA1) (All versions >= V8.3), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA1) (All versions >= V8.3), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA1) (All versions >= V8.3), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA1) (All versions >= V8.3), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA1) (All versions >= V8.3), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA1) (All versions >= V8.3), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA1) (All versions >= V8.3), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA1) (All versions >= V8.3). Affected devices are vulnerable to an electromagnetic fault injection. This could allow an attacker to dump and debug the firmware, including the manipulation of memory. Further actions could allow to inject public keys of custom created key pairs which are then signed by the product CA. The generation of a custom certificate allows communication with, and impersonation of, any device of the same version.
Severity
CWE
- CWE-1319 - Improper Protection against Electromagnetic Fault Injection (EM-FI)
Assigner
References
Impacted products
16 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | LOGO! 12/24RCE |
Affected:
V8.3 , < *
(custom)
|
|
| Siemens | LOGO! 12/24RCEo |
Affected:
V8.3 , < *
(custom)
|
|
| Siemens | LOGO! 230RCE |
Affected:
V8.3 , < *
(custom)
|
|
| Siemens | LOGO! 230RCEo |
Affected:
V8.3 , < *
(custom)
|
|
| Siemens | LOGO! 24CE |
Affected:
V8.3 , < *
(custom)
|
|
| Siemens | LOGO! 24CEo |
Affected:
V8.3 , < *
(custom)
|
|
| Siemens | LOGO! 24RCE |
Affected:
V8.3 , < *
(custom)
|
|
| Siemens | LOGO! 24RCEo |
Affected:
V8.3 , < *
(custom)
|
|
| Siemens | SIPLUS LOGO! 12/24RCE |
Affected:
V8.3 , < *
(custom)
|
|
| Siemens | SIPLUS LOGO! 12/24RCEo |
Affected:
V8.3 , < *
(custom)
|
|
| Siemens | SIPLUS LOGO! 230RCE |
Affected:
V8.3 , < *
(custom)
|
|
| Siemens | SIPLUS LOGO! 230RCEo |
Affected:
V8.3 , < *
(custom)
|
|
| Siemens | SIPLUS LOGO! 24CE |
Affected:
V8.3 , < *
(custom)
|
|
| Siemens | SIPLUS LOGO! 24CEo |
Affected:
V8.3 , < *
(custom)
|
|
| Siemens | SIPLUS LOGO! 24RCE |
Affected:
V8.3 , < *
(custom)
|
|
| Siemens | SIPLUS LOGO! 24RCEo |
Affected:
V8.3 , < *
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T13:19:04.591Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-844582.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "LOGO! 12/24RCE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V8.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 12/24RCEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V8.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 230RCE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V8.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 230RCEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V8.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 24CE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V8.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 24CEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V8.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 24RCE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V8.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 24RCEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V8.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 12/24RCE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V8.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 12/24RCEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V8.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 230RCE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V8.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 230RCEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V8.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 24CE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V8.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 24CEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V8.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 24RCE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V8.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 24RCEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V8.3",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA1) (All versions \u003e= V8.3), LOGO! 12/24RCEo (6ED1052-2MD08-0BA1) (All versions \u003e= V8.3), LOGO! 230RCE (6ED1052-1FB08-0BA1) (All versions \u003e= V8.3), LOGO! 230RCEo (6ED1052-2FB08-0BA1) (All versions \u003e= V8.3), LOGO! 24CE (6ED1052-1CC08-0BA1) (All versions \u003e= V8.3), LOGO! 24CEo (6ED1052-2CC08-0BA1) (All versions \u003e= V8.3), LOGO! 24RCE (6ED1052-1HB08-0BA1) (All versions \u003e= V8.3), LOGO! 24RCEo (6ED1052-2HB08-0BA1) (All versions \u003e= V8.3), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA1) (All versions \u003e= V8.3), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA1) (All versions \u003e= V8.3), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA1) (All versions \u003e= V8.3), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA1) (All versions \u003e= V8.3), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA1) (All versions \u003e= V8.3), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA1) (All versions \u003e= V8.3), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA1) (All versions \u003e= V8.3), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA1) (All versions \u003e= V8.3). Affected devices are vulnerable to an electromagnetic fault injection. This could allow an attacker to dump and debug the firmware, including the manipulation of memory. Further actions could allow to inject public keys of custom created key pairs which are then signed by the product CA. The generation of a custom certificate allows communication with, and impersonation of, any device of the same version."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.6,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-1319",
"description": "CWE-1319: Improper Protection against Electromagnetic Fault Injection (EM-FI)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-10-08T08:39:57.161Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-844582.pdf"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-844582.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-42784",
"datePublished": "2023-12-12T10:02:37.510Z",
"dateReserved": "2022-10-11T11:45:41.037Z",
"dateUpdated": "2024-10-08T08:39:57.161Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-42784 (GCVE-0-2022-42784)
Vulnerability from cvelistv5 – Published: 2023-12-12 10:02 – Updated: 2024-10-08 08:39
VLAI
Summary
A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA1) (All versions >= V8.3), LOGO! 12/24RCEo (6ED1052-2MD08-0BA1) (All versions >= V8.3), LOGO! 230RCE (6ED1052-1FB08-0BA1) (All versions >= V8.3), LOGO! 230RCEo (6ED1052-2FB08-0BA1) (All versions >= V8.3), LOGO! 24CE (6ED1052-1CC08-0BA1) (All versions >= V8.3), LOGO! 24CEo (6ED1052-2CC08-0BA1) (All versions >= V8.3), LOGO! 24RCE (6ED1052-1HB08-0BA1) (All versions >= V8.3), LOGO! 24RCEo (6ED1052-2HB08-0BA1) (All versions >= V8.3), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA1) (All versions >= V8.3), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA1) (All versions >= V8.3), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA1) (All versions >= V8.3), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA1) (All versions >= V8.3), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA1) (All versions >= V8.3), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA1) (All versions >= V8.3), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA1) (All versions >= V8.3), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA1) (All versions >= V8.3). Affected devices are vulnerable to an electromagnetic fault injection. This could allow an attacker to dump and debug the firmware, including the manipulation of memory. Further actions could allow to inject public keys of custom created key pairs which are then signed by the product CA. The generation of a custom certificate allows communication with, and impersonation of, any device of the same version.
Severity
CWE
- CWE-1319 - Improper Protection against Electromagnetic Fault Injection (EM-FI)
Assigner
References
Impacted products
16 products
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | LOGO! 12/24RCE |
Affected:
V8.3 , < *
(custom)
|
|
| Siemens | LOGO! 12/24RCEo |
Affected:
V8.3 , < *
(custom)
|
|
| Siemens | LOGO! 230RCE |
Affected:
V8.3 , < *
(custom)
|
|
| Siemens | LOGO! 230RCEo |
Affected:
V8.3 , < *
(custom)
|
|
| Siemens | LOGO! 24CE |
Affected:
V8.3 , < *
(custom)
|
|
| Siemens | LOGO! 24CEo |
Affected:
V8.3 , < *
(custom)
|
|
| Siemens | LOGO! 24RCE |
Affected:
V8.3 , < *
(custom)
|
|
| Siemens | LOGO! 24RCEo |
Affected:
V8.3 , < *
(custom)
|
|
| Siemens | SIPLUS LOGO! 12/24RCE |
Affected:
V8.3 , < *
(custom)
|
|
| Siemens | SIPLUS LOGO! 12/24RCEo |
Affected:
V8.3 , < *
(custom)
|
|
| Siemens | SIPLUS LOGO! 230RCE |
Affected:
V8.3 , < *
(custom)
|
|
| Siemens | SIPLUS LOGO! 230RCEo |
Affected:
V8.3 , < *
(custom)
|
|
| Siemens | SIPLUS LOGO! 24CE |
Affected:
V8.3 , < *
(custom)
|
|
| Siemens | SIPLUS LOGO! 24CEo |
Affected:
V8.3 , < *
(custom)
|
|
| Siemens | SIPLUS LOGO! 24RCE |
Affected:
V8.3 , < *
(custom)
|
|
| Siemens | SIPLUS LOGO! 24RCEo |
Affected:
V8.3 , < *
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T13:19:04.591Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-844582.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "LOGO! 12/24RCE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V8.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 12/24RCEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V8.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 230RCE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V8.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 230RCEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V8.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 24CE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V8.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 24CEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V8.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 24RCE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V8.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "LOGO! 24RCEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V8.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 12/24RCE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V8.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 12/24RCEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V8.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 230RCE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V8.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 230RCEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V8.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 24CE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V8.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 24CEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V8.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 24RCE",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V8.3",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS LOGO! 24RCEo",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "V8.3",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA1) (All versions \u003e= V8.3), LOGO! 12/24RCEo (6ED1052-2MD08-0BA1) (All versions \u003e= V8.3), LOGO! 230RCE (6ED1052-1FB08-0BA1) (All versions \u003e= V8.3), LOGO! 230RCEo (6ED1052-2FB08-0BA1) (All versions \u003e= V8.3), LOGO! 24CE (6ED1052-1CC08-0BA1) (All versions \u003e= V8.3), LOGO! 24CEo (6ED1052-2CC08-0BA1) (All versions \u003e= V8.3), LOGO! 24RCE (6ED1052-1HB08-0BA1) (All versions \u003e= V8.3), LOGO! 24RCEo (6ED1052-2HB08-0BA1) (All versions \u003e= V8.3), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA1) (All versions \u003e= V8.3), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA1) (All versions \u003e= V8.3), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA1) (All versions \u003e= V8.3), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA1) (All versions \u003e= V8.3), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA1) (All versions \u003e= V8.3), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA1) (All versions \u003e= V8.3), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA1) (All versions \u003e= V8.3), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA1) (All versions \u003e= V8.3). Affected devices are vulnerable to an electromagnetic fault injection. This could allow an attacker to dump and debug the firmware, including the manipulation of memory. Further actions could allow to inject public keys of custom created key pairs which are then signed by the product CA. The generation of a custom certificate allows communication with, and impersonation of, any device of the same version."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.6,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-1319",
"description": "CWE-1319: Improper Protection against Electromagnetic Fault Injection (EM-FI)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-10-08T08:39:57.161Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-844582.pdf"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-844582.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-42784",
"datePublished": "2023-12-12T10:02:37.510Z",
"dateReserved": "2022-10-11T11:45:41.037Z",
"dateUpdated": "2024-10-08T08:39:57.161Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}