Find a vulnerability
Search criteria
5 vulnerabilities found for 1756-en4tr by rockwellautomation
VAR-202509-1087
Vulnerability from variot - Updated: 2025-09-26 23:32A security issue exists in the protected mode of 1756-EN4TR and 1756-EN2TR communication modules, where a Concurrent Forward Close operation can trigger a Major Non-Recoverable (MNFR) fault. This condition may lead to unexpected system crashes and loss of device availability. 1756-en2tr series a firmware, 1756-en2tr series b firmware, 1756-en2tr series c firmware etc. Rockwell Automation There are unspecified vulnerabilities in the product.Service operation interruption (DoS) It may be in a state
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202509-1087",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "1756-en2tr series a",
"scope": "lt",
"trust": 1.0,
"vendor": "rockwellautomation",
"version": "7.001"
},
{
"model": "1756-en4tr",
"scope": "lt",
"trust": 1.0,
"vendor": "rockwellautomation",
"version": "7.001"
},
{
"model": "1756-en4trxt",
"scope": "lt",
"trust": 1.0,
"vendor": "rockwellautomation",
"version": "7.001"
},
{
"model": "1756-en2tr series c",
"scope": "lt",
"trust": 1.0,
"vendor": "rockwellautomation",
"version": "7.001"
},
{
"model": "1756-en2tr series b",
"scope": "lt",
"trust": 1.0,
"vendor": "rockwellautomation",
"version": "7.001"
},
{
"model": "1756-en2tr series b",
"scope": null,
"trust": 0.8,
"vendor": "rockwell automation",
"version": null
},
{
"model": "1756-en2tr series c",
"scope": null,
"trust": 0.8,
"vendor": "rockwell automation",
"version": null
},
{
"model": "1756-en4trxt",
"scope": null,
"trust": 0.8,
"vendor": "rockwell automation",
"version": null
},
{
"model": "1756-en4tr",
"scope": null,
"trust": 0.8,
"vendor": "rockwell automation",
"version": null
},
{
"model": "1756-en2tr series a",
"scope": null,
"trust": 0.8,
"vendor": "rockwell automation",
"version": null
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2025-014247"
},
{
"db": "NVD",
"id": "CVE-2025-8007"
}
]
},
"cve": "CVE-2025-8007",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "ADJACENT",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"exploitabilityScore": 2.8,
"id": "CVE-2025-8007",
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Adjacent Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 6.5,
"baseSeverity": "Medium",
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "CVE-2025-8007",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2025-8007",
"trust": 1.0,
"value": "MEDIUM"
},
{
"author": "PSIRT@rockwellautomation.com",
"id": "CVE-2025-8007",
"trust": 1.0,
"value": "High"
},
{
"author": "NVD",
"id": "CVE-2025-8007",
"trust": 0.8,
"value": "Medium"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2025-014247"
},
{
"db": "NVD",
"id": "CVE-2025-8007"
},
{
"db": "NVD",
"id": "CVE-2025-8007"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A security issue exists in the protected mode of 1756-EN4TR and 1756-EN2TR communication modules, where a Concurrent Forward Close operation can trigger a Major Non-Recoverable (MNFR) fault. This condition may lead to unexpected system crashes and loss of device availability. 1756-en2tr series a firmware, 1756-en2tr series b firmware, 1756-en2tr series c firmware etc. Rockwell Automation There are unspecified vulnerabilities in the product.Service operation interruption (DoS) It may be in a state",
"sources": [
{
"db": "NVD",
"id": "CVE-2025-8007"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-014247"
}
],
"trust": 1.62
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2025-8007",
"trust": 2.6
},
{
"db": "ICS CERT",
"id": "ICSA-25-226-31",
"trust": 0.8
},
{
"db": "JVN",
"id": "JVNVU96783966",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2025-014247",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2025-014247"
},
{
"db": "NVD",
"id": "CVE-2025-8007"
}
]
},
"id": "VAR-202509-1087",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VARIoT devices database",
"id": null
}
],
"trust": 0.41666666
},
"last_update_date": "2025-09-26T23:32:45.679000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "NVD-CWE-noinfo",
"trust": 1.0
},
{
"problemtype": "CWE-20",
"trust": 1.0
},
{
"problemtype": "Inappropriate input confirmation (CWE-20) [ others ]",
"trust": 0.8
},
{
"problemtype": " Lack of information (CWE-noinfo) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2025-014247"
},
{
"db": "NVD",
"id": "CVE-2025-8007"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.8,
"url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.sd1739.html"
},
{
"trust": 0.8,
"url": "https://jvn.jp/vu/jvnvu96783966/"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2025-8007"
},
{
"trust": 0.8,
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-226-31"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2025-014247"
},
{
"db": "NVD",
"id": "CVE-2025-8007"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "JVNDB",
"id": "JVNDB-2025-014247"
},
{
"db": "NVD",
"id": "CVE-2025-8007"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-09-24T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2025-014247"
},
{
"date": "2025-09-09T13:15:32.143000",
"db": "NVD",
"id": "CVE-2025-8007"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-09-24T02:26:00",
"db": "JVNDB",
"id": "JVNDB-2025-014247"
},
{
"date": "2025-09-17T15:47:58.823000",
"db": "NVD",
"id": "CVE-2025-8007"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "plural \u00a0Rockwell\u00a0Automation\u00a0 Product vulnerabilities",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2025-014247"
}
],
"trust": 0.8
}
}
VAR-202509-0459
Vulnerability from variot - Updated: 2025-09-20 23:24A security issue exists in the protected mode of EN4TR devices, where sending specifically crafted messages during a Forward Close operation can cause the device to crash. 1756-en2tr series a firmware, 1756-en2tr series b firmware, 1756-en2tr series c firmware etc. Rockwell Automation The product contains an exceptional state handling vulnerability.Service operation interruption (DoS) It may be in a state
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202509-0459",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "1756-en2tr series a",
"scope": "lt",
"trust": 1.0,
"vendor": "rockwellautomation",
"version": "7.001"
},
{
"model": "1756-en4tr",
"scope": "lt",
"trust": 1.0,
"vendor": "rockwellautomation",
"version": "7.001"
},
{
"model": "1756-en4trxt",
"scope": "lt",
"trust": 1.0,
"vendor": "rockwellautomation",
"version": "7.001"
},
{
"model": "1756-en2tr series c",
"scope": "lt",
"trust": 1.0,
"vendor": "rockwellautomation",
"version": "7.001"
},
{
"model": "1756-en2tr series b",
"scope": "lt",
"trust": 1.0,
"vendor": "rockwellautomation",
"version": "7.001"
},
{
"model": "1756-en2tr series a",
"scope": null,
"trust": 0.8,
"vendor": "rockwell automation",
"version": null
},
{
"model": "1756-en4trxt",
"scope": null,
"trust": 0.8,
"vendor": "rockwell automation",
"version": null
},
{
"model": "1756-en2tr series b",
"scope": null,
"trust": 0.8,
"vendor": "rockwell automation",
"version": null
},
{
"model": "1756-en2tr series c",
"scope": null,
"trust": 0.8,
"vendor": "rockwell automation",
"version": null
},
{
"model": "1756-en4tr",
"scope": null,
"trust": 0.8,
"vendor": "rockwell automation",
"version": null
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2025-014085"
},
{
"db": "NVD",
"id": "CVE-2025-8008"
}
]
},
"cve": "CVE-2025-8008",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "ADJACENT",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"exploitabilityScore": 2.8,
"id": "CVE-2025-8008",
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Adjacent Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 6.5,
"baseSeverity": "Medium",
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "CVE-2025-8008",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2025-8008",
"trust": 1.0,
"value": "MEDIUM"
},
{
"author": "PSIRT@rockwellautomation.com",
"id": "CVE-2025-8008",
"trust": 1.0,
"value": "High"
},
{
"author": "NVD",
"id": "CVE-2025-8008",
"trust": 0.8,
"value": "Medium"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2025-014085"
},
{
"db": "NVD",
"id": "CVE-2025-8008"
},
{
"db": "NVD",
"id": "CVE-2025-8008"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A security issue exists in the protected mode of EN4TR devices, where sending specifically crafted messages during a Forward Close operation can cause the device to crash. 1756-en2tr series a firmware, 1756-en2tr series b firmware, 1756-en2tr series c firmware etc. Rockwell Automation The product contains an exceptional state handling vulnerability.Service operation interruption (DoS) It may be in a state",
"sources": [
{
"db": "NVD",
"id": "CVE-2025-8008"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-014085"
}
],
"trust": 1.62
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2025-8008",
"trust": 2.6
},
{
"db": "JVN",
"id": "JVNVU96783966",
"trust": 0.8
},
{
"db": "ICS CERT",
"id": "ICSA-25-226-31",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2025-014085",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2025-014085"
},
{
"db": "NVD",
"id": "CVE-2025-8008"
}
]
},
"id": "VAR-202509-0459",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VARIoT devices database",
"id": null
}
],
"trust": 0.41666666
},
"last_update_date": "2025-09-20T23:24:07.391000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-755",
"trust": 1.0
},
{
"problemtype": "Improper handling in exceptional conditions (CWE-755) [ others ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2025-014085"
},
{
"db": "NVD",
"id": "CVE-2025-8008"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.8,
"url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.sd1739.html"
},
{
"trust": 0.8,
"url": "https://jvn.jp/vu/jvnvu96783966/"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2025-8008"
},
{
"trust": 0.8,
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-226-31"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2025-014085"
},
{
"db": "NVD",
"id": "CVE-2025-8008"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "JVNDB",
"id": "JVNDB-2025-014085"
},
{
"db": "NVD",
"id": "CVE-2025-8008"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-09-19T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2025-014085"
},
{
"date": "2025-09-09T13:15:32.317000",
"db": "NVD",
"id": "CVE-2025-8008"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-09-19T03:49:00",
"db": "JVNDB",
"id": "JVNDB-2025-014085"
},
{
"date": "2025-09-17T15:42:27.340000",
"db": "NVD",
"id": "CVE-2025-8008"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "plural \u00a0Rockwell\u00a0Automation\u00a0 Product Exceptional State Handling Vulnerability",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2025-014085"
}
],
"trust": 0.8
}
}
VAR-202307-1042
Vulnerability from variot - Updated: 2024-09-28 23:03Where this vulnerability exists in the Rockwell Automation 1756-EN4* Ethernet/IP communication products, it could allow a malicious user to cause a denial of service by asserting the target system through maliciously crafted CIP messages. Rockwell Automation of 1756-en4tr firmware, 1756-en4trk firmware, 1756-en4trxt An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state. Rockwell Automation 1756 is a scalable controller solution from Rockwell Automation, USA. It can address a large number of I/O points.
Rockwell Automation 1756-EN4 has a denial of service vulnerability. The vulnerability is caused by the failure to properly handle the input error message
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202307-1042",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "1756-en4trxt",
"scope": "eq",
"trust": 1.0,
"vendor": "rockwellautomation",
"version": null
},
{
"model": "1756-en4tr",
"scope": "eq",
"trust": 1.0,
"vendor": "rockwellautomation",
"version": null
},
{
"model": "1756-en4trk",
"scope": "eq",
"trust": 1.0,
"vendor": "rockwellautomation",
"version": null
},
{
"model": "1756-en4trxt",
"scope": null,
"trust": 0.8,
"vendor": "rockwell automation",
"version": null
},
{
"model": "1756-en4trk",
"scope": null,
"trust": 0.8,
"vendor": "rockwell automation",
"version": null
},
{
"model": "1756-en4tr",
"scope": null,
"trust": 0.8,
"vendor": "rockwell automation",
"version": null
},
{
"model": "automation 1756-en4",
"scope": null,
"trust": 0.6,
"vendor": "rockwell",
"version": null
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-39272"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-023054"
},
{
"db": "NVD",
"id": "CVE-2023-3596"
}
]
},
"cve": "CVE-2023-3596",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 7.8,
"confidentialityImpact": "NONE",
"exploitabilityScore": 10.0,
"id": "CNVD-2024-39272",
"impactScore": 6.9,
"integrityImpact": "NONE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"exploitabilityScore": 3.9,
"id": "CVE-2023-3596",
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 2.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 7.5,
"baseSeverity": "High",
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "CVE-2023-3596",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2023-3596",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "PSIRT@rockwellautomation.com",
"id": "CVE-2023-3596",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "NVD",
"id": "CVE-2023-3596",
"trust": 0.8,
"value": "High"
},
{
"author": "CNVD",
"id": "CNVD-2024-39272",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNNVD",
"id": "CNNVD-202307-1154",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-39272"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-023054"
},
{
"db": "CNNVD",
"id": "CNNVD-202307-1154"
},
{
"db": "NVD",
"id": "CVE-2023-3596"
},
{
"db": "NVD",
"id": "CVE-2023-3596"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "\nWhere this vulnerability exists in the Rockwell Automation 1756-EN4* Ethernet/IP communication products, it could allow a malicious user to cause a denial of service by asserting the target system through maliciously crafted CIP messages. Rockwell Automation of 1756-en4tr firmware, 1756-en4trk firmware, 1756-en4trxt An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state. Rockwell Automation 1756 is a scalable controller solution from Rockwell Automation, USA. It can address a large number of I/O points. \n\nRockwell Automation 1756-EN4 has a denial of service vulnerability. The vulnerability is caused by the failure to properly handle the input error message",
"sources": [
{
"db": "NVD",
"id": "CVE-2023-3596"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-023054"
},
{
"db": "CNVD",
"id": "CNVD-2024-39272"
},
{
"db": "VULMON",
"id": "CVE-2023-3596"
}
],
"trust": 2.25
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2023-3596",
"trust": 3.9
},
{
"db": "ICS CERT",
"id": "ICSA-23-193-01",
"trust": 0.8
},
{
"db": "JVN",
"id": "JVNVU95608136",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2023-023054",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2024-39272",
"trust": 0.6
},
{
"db": "AUSCERT",
"id": "ESB-2023.3937",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202307-1154",
"trust": 0.6
},
{
"db": "VULMON",
"id": "CVE-2023-3596",
"trust": 0.1
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-39272"
},
{
"db": "VULMON",
"id": "CVE-2023-3596"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-023054"
},
{
"db": "CNNVD",
"id": "CNNVD-202307-1154"
},
{
"db": "NVD",
"id": "CVE-2023-3596"
}
]
},
"id": "VAR-202307-1042",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-39272"
}
],
"trust": 0.06
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-39272"
}
]
},
"last_update_date": "2024-09-28T23:03:47.763000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Patch for Rockwell Automation 1756-EN4 Denial of Service Vulnerability",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchInfo/show/588236"
},
{
"title": "Rockwell Automation 1756 Buffer error vulnerability fix",
"trust": 0.6,
"url": "http://123.124.177.30/web/xxk/bdxqById.tag?id=247029"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-39272"
},
{
"db": "CNNVD",
"id": "CNNVD-202307-1154"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.0
},
{
"problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-023054"
},
{
"db": "NVD",
"id": "CVE-2023-3596"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.7,
"url": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1140010"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2023-3596"
},
{
"trust": 0.8,
"url": "https://jvn.jp/vu/jvnvu95608136/"
},
{
"trust": 0.8,
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-193-01"
},
{
"trust": 0.6,
"url": "https://www.auscert.org.au/bulletins/esb-2023.3937"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2023-3596/"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-39272"
},
{
"db": "VULMON",
"id": "CVE-2023-3596"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-023054"
},
{
"db": "CNNVD",
"id": "CNNVD-202307-1154"
},
{
"db": "NVD",
"id": "CVE-2023-3596"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2024-39272"
},
{
"db": "VULMON",
"id": "CVE-2023-3596"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-023054"
},
{
"db": "CNNVD",
"id": "CNNVD-202307-1154"
},
{
"db": "NVD",
"id": "CVE-2023-3596"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-09-06T00:00:00",
"db": "CNVD",
"id": "CNVD-2024-39272"
},
{
"date": "2023-07-12T00:00:00",
"db": "VULMON",
"id": "CVE-2023-3596"
},
{
"date": "2024-01-25T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2023-023054"
},
{
"date": "2023-07-12T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202307-1154"
},
{
"date": "2023-07-12T13:15:09.947000",
"db": "NVD",
"id": "CVE-2023-3596"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-09-26T00:00:00",
"db": "CNVD",
"id": "CNVD-2024-39272"
},
{
"date": "2023-07-12T00:00:00",
"db": "VULMON",
"id": "CVE-2023-3596"
},
{
"date": "2024-01-25T06:13:00",
"db": "JVNDB",
"id": "JVNDB-2023-023054"
},
{
"date": "2023-07-21T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202307-1154"
},
{
"date": "2023-07-20T19:51:44.103000",
"db": "NVD",
"id": "CVE-2023-3596"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202307-1154"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "plural \u00a0Rockwell\u00a0Automation\u00a0 Out-of-bounds write vulnerabilities in the product",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-023054"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "buffer error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202307-1154"
}
],
"trust": 0.6
}
}
CVE-2023-3596 (GCVE-0-2023-3596)
Vulnerability from nvd – Published: 2023-07-12 12:51 – Updated: 2024-11-07 16:59- CWE-787 - Out-of-bounds Write
| Vendor | Product | Version | |
|---|---|---|---|
| Rockwell Automation | 1756-EN4TR Series A |
Affected:
<=5.001
|
|
| Rockwell Automation | 1756-EN4TRK Series A |
Affected:
<=5.001
|
|
| Rockwell Automation | 1756-EN4TRXT Series A |
Affected:
<=5.001
|
|
| rockwellautomation | 1756-en4tr |
Affected:
0 , ≤ 5.001
(custom)
cpe:2.3:h:rockwellautomation:1756-en4tr:-:*:*:*:*:*:*:* |
|
| rockwellautomation | 1756-en4trk |
Affected:
0 , ≤ 5.001
(custom)
cpe:2.3:h:rockwellautomation:1756-en4trk:-:*:*:*:*:*:*:* |
|
| rockwellautomation | 1756-en4trxt |
Affected:
0 , ≤ 5.001
(custom)
cpe:2.3:h:rockwellautomation:1756-en4trxt:-:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T07:01:56.685Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1140010"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:h:rockwellautomation:1756-en4tr:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "1756-en4tr",
"vendor": "rockwellautomation",
"versions": [
{
"lessThanOrEqual": "5.001",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:rockwellautomation:1756-en4trk:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "1756-en4trk",
"vendor": "rockwellautomation",
"versions": [
{
"lessThanOrEqual": "5.001",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:rockwellautomation:1756-en4trxt:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "1756-en4trxt",
"vendor": "rockwellautomation",
"versions": [
{
"lessThanOrEqual": "5.001",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-3596",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-07T16:56:23.761081Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-07T16:59:33.267Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "1756-EN4TR Series A",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=5.001"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN4TRK Series A",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=5.001"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN4TRXT Series A\t",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=5.001"
}
]
}
],
"datePublic": "2023-07-12T12:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eWhere this vulnerability exists in the Rockwell Automation 1756-EN4* Ethernet/IP communication products, it could allow a malicious user to cause a denial of service by asserting the target system through maliciously crafted CIP messages.\u003c/span\u003e\n\n"
}
],
"value": "\nWhere this vulnerability exists in the Rockwell Automation 1756-EN4* Ethernet/IP communication products, it could allow a malicious user to cause a denial of service by asserting the target system through maliciously crafted CIP messages.\n\n"
}
],
"impacts": [
{
"capecId": "CAPEC-100",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-100 Overflow Buffers"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-787",
"description": "CWE-787 Out-of-bounds Write",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-07-12T13:16:21.672Z",
"orgId": "b73dd486-f505-4403-b634-40b078b177f0",
"shortName": "Rockwell"
},
"references": [
{
"url": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1140010"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\u003cul\u003e\u003cli\u003e\u003cstrong\u003eUpdate firmware. \u003c/strong\u003eUpdate EN4* ControlLogix communications modules to firmware revision 5.002.\u0026nbsp;\u003c/li\u003e\u003cli\u003e\u003cstrong\u003eProperly segment networks.\u003c/strong\u003e\u0026nbsp;Given a cyber actor would require network connectivity to the communication module to exploit the vulnerability, organizations should ensure ICS/SCADA networks are properly segmented within the process structure as well as from the Internet and other non-essential networks. \u003c/li\u003e\u003cli\u003e\u003cstrong\u003eImplement detection signatures.\u003c/strong\u003e\u0026nbsp;Use appended Snort signatures to monitor and detect anomalous Common Industrial Protocol (CIP) packets to Rockwell Automation devices. \u003c/li\u003e\u003c/ul\u003e\n\n\u003cbr\u003e"
}
],
"value": "\n * Update firmware. Update EN4* ControlLogix communications modules to firmware revision 5.002.\u00a0\n * Properly segment networks.\u00a0Given a cyber actor would require network connectivity to the communication module to exploit the vulnerability, organizations should ensure ICS/SCADA networks are properly segmented within the process structure as well as from the Internet and other non-essential networks. \n * Implement detection signatures.\u00a0Use appended Snort signatures to monitor and detect anomalous Common Industrial Protocol (CIP) packets to Rockwell Automation devices. \n\n\n\n\n\n"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Rockwell Automation Allen-Bradley ControlLogix Communication Modules vulnerable to Denial of Service ",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
"assignerShortName": "Rockwell",
"cveId": "CVE-2023-3596",
"datePublished": "2023-07-12T12:51:19.498Z",
"dateReserved": "2023-07-10T15:34:53.790Z",
"dateUpdated": "2024-11-07T16:59:33.267Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-3596 (GCVE-0-2023-3596)
Vulnerability from cvelistv5 – Published: 2023-07-12 12:51 – Updated: 2024-11-07 16:59- CWE-787 - Out-of-bounds Write
| Vendor | Product | Version | |
|---|---|---|---|
| Rockwell Automation | 1756-EN4TR Series A |
Affected:
<=5.001
|
|
| Rockwell Automation | 1756-EN4TRK Series A |
Affected:
<=5.001
|
|
| Rockwell Automation | 1756-EN4TRXT Series A |
Affected:
<=5.001
|
|
| rockwellautomation | 1756-en4tr |
Affected:
0 , ≤ 5.001
(custom)
cpe:2.3:h:rockwellautomation:1756-en4tr:-:*:*:*:*:*:*:* |
|
| rockwellautomation | 1756-en4trk |
Affected:
0 , ≤ 5.001
(custom)
cpe:2.3:h:rockwellautomation:1756-en4trk:-:*:*:*:*:*:*:* |
|
| rockwellautomation | 1756-en4trxt |
Affected:
0 , ≤ 5.001
(custom)
cpe:2.3:h:rockwellautomation:1756-en4trxt:-:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T07:01:56.685Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1140010"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:h:rockwellautomation:1756-en4tr:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "1756-en4tr",
"vendor": "rockwellautomation",
"versions": [
{
"lessThanOrEqual": "5.001",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:rockwellautomation:1756-en4trk:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "1756-en4trk",
"vendor": "rockwellautomation",
"versions": [
{
"lessThanOrEqual": "5.001",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:rockwellautomation:1756-en4trxt:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "1756-en4trxt",
"vendor": "rockwellautomation",
"versions": [
{
"lessThanOrEqual": "5.001",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-3596",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-07T16:56:23.761081Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-07T16:59:33.267Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "1756-EN4TR Series A",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=5.001"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN4TRK Series A",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=5.001"
}
]
},
{
"defaultStatus": "unaffected",
"product": "1756-EN4TRXT Series A\t",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "\u003c=5.001"
}
]
}
],
"datePublic": "2023-07-12T12:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eWhere this vulnerability exists in the Rockwell Automation 1756-EN4* Ethernet/IP communication products, it could allow a malicious user to cause a denial of service by asserting the target system through maliciously crafted CIP messages.\u003c/span\u003e\n\n"
}
],
"value": "\nWhere this vulnerability exists in the Rockwell Automation 1756-EN4* Ethernet/IP communication products, it could allow a malicious user to cause a denial of service by asserting the target system through maliciously crafted CIP messages.\n\n"
}
],
"impacts": [
{
"capecId": "CAPEC-100",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-100 Overflow Buffers"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-787",
"description": "CWE-787 Out-of-bounds Write",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-07-12T13:16:21.672Z",
"orgId": "b73dd486-f505-4403-b634-40b078b177f0",
"shortName": "Rockwell"
},
"references": [
{
"url": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1140010"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\u003cul\u003e\u003cli\u003e\u003cstrong\u003eUpdate firmware. \u003c/strong\u003eUpdate EN4* ControlLogix communications modules to firmware revision 5.002.\u0026nbsp;\u003c/li\u003e\u003cli\u003e\u003cstrong\u003eProperly segment networks.\u003c/strong\u003e\u0026nbsp;Given a cyber actor would require network connectivity to the communication module to exploit the vulnerability, organizations should ensure ICS/SCADA networks are properly segmented within the process structure as well as from the Internet and other non-essential networks. \u003c/li\u003e\u003cli\u003e\u003cstrong\u003eImplement detection signatures.\u003c/strong\u003e\u0026nbsp;Use appended Snort signatures to monitor and detect anomalous Common Industrial Protocol (CIP) packets to Rockwell Automation devices. \u003c/li\u003e\u003c/ul\u003e\n\n\u003cbr\u003e"
}
],
"value": "\n * Update firmware. Update EN4* ControlLogix communications modules to firmware revision 5.002.\u00a0\n * Properly segment networks.\u00a0Given a cyber actor would require network connectivity to the communication module to exploit the vulnerability, organizations should ensure ICS/SCADA networks are properly segmented within the process structure as well as from the Internet and other non-essential networks. \n * Implement detection signatures.\u00a0Use appended Snort signatures to monitor and detect anomalous Common Industrial Protocol (CIP) packets to Rockwell Automation devices. \n\n\n\n\n\n"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Rockwell Automation Allen-Bradley ControlLogix Communication Modules vulnerable to Denial of Service ",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
"assignerShortName": "Rockwell",
"cveId": "CVE-2023-3596",
"datePublished": "2023-07-12T12:51:19.498Z",
"dateReserved": "2023-07-10T15:34:53.790Z",
"dateUpdated": "2024-11-07T16:59:33.267Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}