    CVE-2026-12656 (GCVE-0-2026-12656)

    Vulnerability from nvd – Published: 2026-10-13 14:12 – Updated: 2026-10-13 15:49
    VLAI
    Title
    1732E ArmorBlock® - Multiple Vulnerabilities
    Summary
    A denial-of-service security issue exists in the affected product and version. The security issue stems from improper handling of network storm traffic, which can interrupt communication, cause device faults, and affect open TCP and UDP ports. A power cycle is required to recover the device to its normal state.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-10-13 14:52 UTC
    CWE
    • CWE-770 - Allocation of Resources Without Limits or Throttling
    Assigner
    Rockwell CNA under the icscert root
    CNA scorecard C 74/100 over 47 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Rockwell Automation 1732E ArmorBlock® I/O Affected: 0 , ≤ 3.012 (custom)
    Create a notification for this product.
    Date Public
    2026-10-13 13:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-12656",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-10-13T14:52:40.707825Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-10-13T15:49:47.082Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "1732E ArmorBlock\u00ae I/O",
              "vendor": "Rockwell Automation",
              "versions": [
                {
                  "lessThanOrEqual": "3.012",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "datePublic": "2026-10-13T13:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eA denial-of-service security issue exists in the affected product and version. The security issue stems from improper handling of network storm traffic, which can interrupt communication, cause device faults, and affect open TCP and UDP ports. A power cycle is required to recover the device to its normal state.\u003c/p\u003e"
                }
              ],
              "value": "A denial-of-service security issue exists in the affected product and version. The security issue stems from improper handling of network storm traffic, which can interrupt communication, cause device faults, and affect open TCP and UDP ports. A power cycle is required to recover the device to its normal state."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "NONE",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-770",
                  "description": "CWE-770: Allocation of Resources Without Limits or Throttling",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-10-13T14:22:53.775Z",
            "orgId": "b73dd486-f505-4403-b634-40b078b177f0",
            "shortName": "Rockwell"
          },
          "references": [
            {
              "url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1801.html"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "3.013 or later"
                }
              ],
              "value": "3.013 or later"
            }
          ],
          "source": {
            "advisory": "SD1801",
            "discovery": "INTERNAL"
          },
          "title": "1732E ArmorBlock\u00ae - Multiple Vulnerabilities",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
        "assignerShortName": "Rockwell",
        "cveId": "CVE-2026-12656",
        "datePublished": "2026-10-13T14:12:58.682Z",
        "dateReserved": "2026-06-18T18:49:04.257Z",
        "dateUpdated": "2026-10-13T15:49:47.082Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-12655 (GCVE-0-2026-12655)

    Vulnerability from nvd – Published: 2026-10-13 14:08 – Updated: 2026-10-15 19:14
    VLAI
    Title
    1732E ArmorBlock® - Multiple Vulnerabilities
    Summary
    A security issue exists within 1732E ArmorBlock® I/O, where an unauthenticated attacker can change the device's webserver password without valid credentials. This could result in admin account takeover or unauthorized modification of device configuration.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-10-15 17:32 UTC
    CWE
    • CWE-294 - Authentication Bypass by Capture-replay
    Assigner
    Rockwell CNA under the icscert root
    CNA scorecard C 74/100 over 47 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Rockwell Automation 1732E ArmorBlock® I/O Affected: 0 , ≤ 3.012 (custom)
    Create a notification for this product.
    Date Public
    2026-10-13 13:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-12655",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-10-15T17:32:59.205388Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-10-15T19:14:57.983Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "1732E ArmorBlock\u00ae I/O",
              "vendor": "Rockwell Automation",
              "versions": [
                {
                  "lessThanOrEqual": "3.012",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "datePublic": "2026-10-13T13:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eA security issue exists within 1732E ArmorBlock\u00ae I/O, where an unauthenticated attacker can change the device\u0027s webserver password without valid credentials. This could result in admin account takeover or unauthorized modification of device configuration.\u003c/p\u003e"
                }
              ],
              "value": "A security issue exists within 1732E ArmorBlock\u00ae I/O, where an unauthenticated attacker can change the device\u0027s webserver password without valid credentials. This could result in admin account takeover or unauthorized modification of device configuration."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "NONE",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-294",
                  "description": "CWE-294: Authentication Bypass by Capture-replay",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-10-13T14:08:36.952Z",
            "orgId": "b73dd486-f505-4403-b634-40b078b177f0",
            "shortName": "Rockwell"
          },
          "references": [
            {
              "url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1801.html"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "3.013 or later"
                }
              ],
              "value": "3.013 or later"
            }
          ],
          "source": {
            "advisory": "SD1801",
            "discovery": "INTERNAL"
          },
          "title": "1732E ArmorBlock\u00ae - Multiple Vulnerabilities",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
        "assignerShortName": "Rockwell",
        "cveId": "CVE-2026-12655",
        "datePublished": "2026-10-13T14:08:36.952Z",
        "dateReserved": "2026-06-18T18:48:53.410Z",
        "dateUpdated": "2026-10-15T19:14:57.983Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-12656 (GCVE-0-2026-12656)

    Vulnerability from cvelistv5 – Published: 2026-10-13 14:12 – Updated: 2026-10-13 15:49
    VLAI
    Title
    1732E ArmorBlock® - Multiple Vulnerabilities
    Summary
    A denial-of-service security issue exists in the affected product and version. The security issue stems from improper handling of network storm traffic, which can interrupt communication, cause device faults, and affect open TCP and UDP ports. A power cycle is required to recover the device to its normal state.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-10-13 14:52 UTC
    CWE
    • CWE-770 - Allocation of Resources Without Limits or Throttling
    Assigner
    Rockwell CNA under the icscert root
    CNA scorecard C 74/100 over 47 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Rockwell Automation 1732E ArmorBlock® I/O Affected: 0 , ≤ 3.012 (custom)
    Create a notification for this product.
    Date Public
    2026-10-13 13:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-12656",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-10-13T14:52:40.707825Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-10-13T15:49:47.082Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "1732E ArmorBlock\u00ae I/O",
              "vendor": "Rockwell Automation",
              "versions": [
                {
                  "lessThanOrEqual": "3.012",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "datePublic": "2026-10-13T13:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eA denial-of-service security issue exists in the affected product and version. The security issue stems from improper handling of network storm traffic, which can interrupt communication, cause device faults, and affect open TCP and UDP ports. A power cycle is required to recover the device to its normal state.\u003c/p\u003e"
                }
              ],
              "value": "A denial-of-service security issue exists in the affected product and version. The security issue stems from improper handling of network storm traffic, which can interrupt communication, cause device faults, and affect open TCP and UDP ports. A power cycle is required to recover the device to its normal state."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "NONE",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-770",
                  "description": "CWE-770: Allocation of Resources Without Limits or Throttling",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-10-13T14:22:53.775Z",
            "orgId": "b73dd486-f505-4403-b634-40b078b177f0",
            "shortName": "Rockwell"
          },
          "references": [
            {
              "url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1801.html"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "3.013 or later"
                }
              ],
              "value": "3.013 or later"
            }
          ],
          "source": {
            "advisory": "SD1801",
            "discovery": "INTERNAL"
          },
          "title": "1732E ArmorBlock\u00ae - Multiple Vulnerabilities",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
        "assignerShortName": "Rockwell",
        "cveId": "CVE-2026-12656",
        "datePublished": "2026-10-13T14:12:58.682Z",
        "dateReserved": "2026-06-18T18:49:04.257Z",
        "dateUpdated": "2026-10-13T15:49:47.082Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-12655 (GCVE-0-2026-12655)

    Vulnerability from cvelistv5 – Published: 2026-10-13 14:08 – Updated: 2026-10-15 19:14
    VLAI
    Title
    1732E ArmorBlock® - Multiple Vulnerabilities
    Summary
    A security issue exists within 1732E ArmorBlock® I/O, where an unauthenticated attacker can change the device's webserver password without valid credentials. This could result in admin account takeover or unauthorized modification of device configuration.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-10-15 17:32 UTC
    CWE
    • CWE-294 - Authentication Bypass by Capture-replay
    Assigner
    Rockwell CNA under the icscert root
    CNA scorecard C 74/100 over 47 records in the last 180 days details
    Impacted products
    Vendor Product Version
    Rockwell Automation 1732E ArmorBlock® I/O Affected: 0 , ≤ 3.012 (custom)
    Create a notification for this product.
    Date Public
    2026-10-13 13:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-12655",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-10-15T17:32:59.205388Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-10-15T19:14:57.983Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "1732E ArmorBlock\u00ae I/O",
              "vendor": "Rockwell Automation",
              "versions": [
                {
                  "lessThanOrEqual": "3.012",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "datePublic": "2026-10-13T13:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cp\u003eA security issue exists within 1732E ArmorBlock\u00ae I/O, where an unauthenticated attacker can change the device\u0027s webserver password without valid credentials. This could result in admin account takeover or unauthorized modification of device configuration.\u003c/p\u003e"
                }
              ],
              "value": "A security issue exists within 1732E ArmorBlock\u00ae I/O, where an unauthenticated attacker can change the device\u0027s webserver password without valid credentials. This could result in admin account takeover or unauthorized modification of device configuration."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "NONE",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-294",
                  "description": "CWE-294: Authentication Bypass by Capture-replay",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-10-13T14:08:36.952Z",
            "orgId": "b73dd486-f505-4403-b634-40b078b177f0",
            "shortName": "Rockwell"
          },
          "references": [
            {
              "url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1801.html"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "3.013 or later"
                }
              ],
              "value": "3.013 or later"
            }
          ],
          "source": {
            "advisory": "SD1801",
            "discovery": "INTERNAL"
          },
          "title": "1732E ArmorBlock\u00ae - Multiple Vulnerabilities",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
        "assignerShortName": "Rockwell",
        "cveId": "CVE-2026-12655",
        "datePublished": "2026-10-13T14:08:36.952Z",
        "dateReserved": "2026-06-18T18:48:53.410Z",
        "dateUpdated": "2026-10-15T19:14:57.983Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }