CWE-306

Missing Authentication for Critical Function

The product does not perform any authentication for functionality that requires a provable user identity or consumes a significant amount of resources.

CVE-2019-6542 (GCVE-0-2019-6542)

Vulnerability from cvelistv5 – Published: 2019-03-28 13:50 – Updated: 2024-08-04 20:23
VLAI
Summary
ENTTEC Datagate MK2, Storm 24, Pixelator all firmware versions prior to (70044,70050,70060)_update_05032019-482 allows an unauthenticated user to initiate a remote reboot, which may be used to cause a denial of service condition.
Severity
No CVSS data available.
CWE
  • CWE-306 - MISSING AUTHENTICATION FOR CRITICAL FUNCTION CWE-306
Assigner
References
Impacted products
Vendor Product Version
ENTTEC Datagate MK2 Affected: < 70044_update_05032019-482
Create a notification for this product.
ENTTEC Storm 24 Affected: < 70050_update_05032019-482
Create a notification for this product.
ENTTEC Pixelator Affected: < 70060_update_05032019-482
Create a notification for this product.
Date Public
2019-03-26 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T20:23:21.439Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-085-03-0"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Datagate MK2",
          "vendor": "ENTTEC",
          "versions": [
            {
              "status": "affected",
              "version": "\u003c 70044_update_05032019-482"
            }
          ]
        },
        {
          "product": "Storm 24",
          "vendor": "ENTTEC",
          "versions": [
            {
              "status": "affected",
              "version": "\u003c 70050_update_05032019-482"
            }
          ]
        },
        {
          "product": "Pixelator",
          "vendor": "ENTTEC",
          "versions": [
            {
              "status": "affected",
              "version": "\u003c 70060_update_05032019-482"
            }
          ]
        }
      ],
      "datePublic": "2019-03-26T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "ENTTEC Datagate MK2, Storm 24, Pixelator all firmware versions prior to (70044,70050,70060)_update_05032019-482 allows an unauthenticated user to initiate a remote reboot, which may be used to cause a denial of service condition."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-306",
              "description": "MISSING AUTHENTICATION FOR CRITICAL FUNCTION CWE-306",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-03-28T13:50:25.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-085-03-0"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2019-6542",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Datagate MK2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "\u003c 70044_update_05032019-482"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Storm 24",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "\u003c 70050_update_05032019-482"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Pixelator",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "\u003c 70060_update_05032019-482"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "ENTTEC"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "ENTTEC Datagate MK2, Storm 24, Pixelator all firmware versions prior to (70044,70050,70060)_update_05032019-482 allows an unauthenticated user to initiate a remote reboot, which may be used to cause a denial of service condition."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "MISSING AUTHENTICATION FOR CRITICAL FUNCTION CWE-306"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-19-085-03-0",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-085-03-0"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2019-6542",
    "datePublished": "2019-03-28T13:50:25.000Z",
    "dateReserved": "2019-01-22T00:00:00.000Z",
    "dateUpdated": "2024-08-04T20:23:21.439Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2019-6543 (GCVE-0-2019-6543)

Vulnerability from cvelistv5 – Published: 2019-02-13 01:00 – Updated: 2024-09-16 18:14
VLAI
Summary
AVEVA Software, LLC InduSoft Web Studio prior to Version 8.1 SP3 and InTouch Edge HMI (formerly InTouch Machine Edition) prior to Version 2017 Update. Code is executed under the program runtime privileges, which could lead to the compromise of the machine.
Severity
No CVSS data available.
CWE
  • CWE-306 - MISSING AUTHENTICATION FOR CRITICAL FUNCTION CWE-306
Assigner
References
Impacted products
Vendor Product Version
ICS-CERT AVEVA Software, LLC InduSoft Web Studio prior to Version 8.1 SP3 and InTouch Edge HMI (formerly InTouch Machine Edition) prior to Version 2017 Update Affected: AVEVA Software, LLC InduSoft Web Studio prior to Version 8.1 SP3 and InTouch Edge HMI (formerly InTouch Machine Edition) prior to Version 2017 Update
Create a notification for this product.
Date Public
2019-02-05 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T20:23:21.426Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-036-01"
          },
          {
            "name": "46342",
            "tags": [
              "exploit",
              "x_refsource_EXPLOIT-DB",
              "x_transferred"
            ],
            "url": "https://www.exploit-db.com/exploits/46342/"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.tenable.com/security/research/tra-2019-04"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AVEVA Software, LLC InduSoft Web Studio prior to Version 8.1 SP3 and InTouch Edge HMI (formerly InTouch Machine Edition) prior to Version 2017 Update",
          "vendor": "ICS-CERT",
          "versions": [
            {
              "status": "affected",
              "version": "AVEVA Software, LLC InduSoft Web Studio prior to Version 8.1 SP3 and InTouch Edge HMI (formerly InTouch Machine Edition) prior to Version 2017 Update"
            }
          ]
        }
      ],
      "datePublic": "2019-02-05T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "AVEVA Software, LLC InduSoft Web Studio prior to Version 8.1 SP3 and InTouch Edge HMI (formerly InTouch Machine Edition) prior to Version 2017 Update. Code is executed under the program runtime privileges, which could lead to the compromise of the machine."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-306",
              "description": "MISSING AUTHENTICATION FOR CRITICAL FUNCTION CWE-306",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-02-14T10:57:01.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-036-01"
        },
        {
          "name": "46342",
          "tags": [
            "exploit",
            "x_refsource_EXPLOIT-DB"
          ],
          "url": "https://www.exploit-db.com/exploits/46342/"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.tenable.com/security/research/tra-2019-04"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "DATE_PUBLIC": "2019-02-05T00:00:00",
          "ID": "CVE-2019-6543",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "AVEVA Software, LLC InduSoft Web Studio prior to Version 8.1 SP3 and InTouch Edge HMI (formerly InTouch Machine Edition) prior to Version 2017 Update",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "AVEVA Software, LLC InduSoft Web Studio prior to Version 8.1 SP3 and InTouch Edge HMI (formerly InTouch Machine Edition) prior to Version 2017 Update"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "ICS-CERT"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "AVEVA Software, LLC InduSoft Web Studio prior to Version 8.1 SP3 and InTouch Edge HMI (formerly InTouch Machine Edition) prior to Version 2017 Update. Code is executed under the program runtime privileges, which could lead to the compromise of the machine."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "MISSING AUTHENTICATION FOR CRITICAL FUNCTION CWE-306"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-19-036-01",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-036-01"
            },
            {
              "name": "46342",
              "refsource": "EXPLOIT-DB",
              "url": "https://www.exploit-db.com/exploits/46342/"
            },
            {
              "name": "https://www.tenable.com/security/research/tra-2019-04",
              "refsource": "MISC",
              "url": "https://www.tenable.com/security/research/tra-2019-04"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2019-6543",
    "datePublished": "2019-02-13T01:00:00.000Z",
    "dateReserved": "2019-01-22T00:00:00.000Z",
    "dateUpdated": "2024-09-16T18:14:25.090Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2019-6820 (GCVE-0-2019-6820)

Vulnerability from cvelistv5 – Published: 2019-05-22 19:40 – Updated: 2026-05-28 19:28
VLAI
Summary
A CWE-306: Missing Authentication for Critical Function vulnerability exists which could cause a modification of device IP configuration (IP address, network mask and gateway IP address) when a specific Ethernet frame is received in all versions of: Modicon M100, Modicon M200, Modicon M221, ATV IMC drive controller, Modicon M241, Modicon M251, Modicon M258, Modicon LMC058, Modicon LMC078, PacDrive Eco ,PacDrive Pro, PacDrive Pro2
CWE
  • CWE-306 - Missing Authentication for Critical Function
Assigner
References
Impacted products
Vendor Product Version
n/a Modicon and PacDrive Controller, All versions of: Modicon M100, Modicon M200, Modicon M221, ATV IMC drive controller, Modicon M241, Modicon M251, Modicon M258, Modicon LMC058, Modicon LMC078, PacDrive Eco ,PacDrive Pro, PacDrive Pro2 Affected: Modicon and PacDrive Controller, All versions of: Modicon M100, Modicon M200, Modicon M221, ATV IMC drive controller, Modicon M241, Modicon M251, Modicon M258, Modicon LMC058, Modicon LMC078, PacDrive Eco ,PacDrive Pro, PacDrive Pro2
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T20:31:04.357Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-02/"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 8.2,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "NONE",
              "integrityImpact": "LOW",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2019-6820",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-05-28T19:28:33.142905Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-05-28T19:28:52.915Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Modicon and PacDrive Controller, All versions of: Modicon M100, Modicon M200, Modicon M221, ATV IMC drive controller, Modicon M241, Modicon M251, Modicon M258, Modicon LMC058, Modicon LMC078, PacDrive Eco ,PacDrive Pro, PacDrive Pro2",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Modicon and PacDrive Controller, All versions of: Modicon M100, Modicon M200, Modicon M221, ATV IMC drive controller, Modicon M241, Modicon M251, Modicon M258, Modicon LMC058, Modicon LMC078, PacDrive Eco ,PacDrive Pro, PacDrive Pro2"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A CWE-306: Missing Authentication for Critical Function vulnerability exists which could cause a modification of device IP configuration (IP address, network mask and gateway IP address) when a specific Ethernet frame is received in all versions of: Modicon M100, Modicon M200, Modicon M221, ATV IMC drive controller, Modicon M241, Modicon M251, Modicon M258, Modicon LMC058, Modicon LMC078, PacDrive Eco ,PacDrive Pro, PacDrive Pro2"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-306",
              "description": "CWE-306: Missing Authentication for Critical Function",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-05-22T19:40:20.000Z",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-02/"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cybersecurity@schneider-electric.com",
          "ID": "CVE-2019-6820",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Modicon and PacDrive Controller, All versions of: Modicon M100, Modicon M200, Modicon M221, ATV IMC drive controller, Modicon M241, Modicon M251, Modicon M258, Modicon LMC058, Modicon LMC078, PacDrive Eco ,PacDrive Pro, PacDrive Pro2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Modicon and PacDrive Controller, All versions of: Modicon M100, Modicon M200, Modicon M221, ATV IMC drive controller, Modicon M241, Modicon M251, Modicon M258, Modicon LMC058, Modicon LMC078, PacDrive Eco ,PacDrive Pro, PacDrive Pro2"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A CWE-306: Missing Authentication for Critical Function vulnerability exists which could cause a modification of device IP configuration (IP address, network mask and gateway IP address) when a specific Ethernet frame is received in all versions of: Modicon M100, Modicon M200, Modicon M221, ATV IMC drive controller, Modicon M241, Modicon M251, Modicon M258, Modicon LMC058, Modicon LMC078, PacDrive Eco ,PacDrive Pro, PacDrive Pro2"
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-306: Missing Authentication for Critical Function"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-02/",
              "refsource": "MISC",
              "url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-02/"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2019-6820",
    "datePublished": "2019-05-22T19:40:20.000Z",
    "dateReserved": "2019-01-25T00:00:00.000Z",
    "dateUpdated": "2026-05-28T19:28:52.915Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2020-10038 (GCVE-0-2020-10038)

Vulnerability from cvelistv5 – Published: 2020-07-14 13:18 – Updated: 2024-08-04 10:50
VLAI
Summary
A vulnerability has been identified in SICAM MMU (All versions < V2.05), SICAM SGU (All versions), SICAM T (All versions < V2.18). An attacker with access to the device's web server might be able to execute administrative commands without authentication.
Severity
No CVSS data available.
CWE
  • CWE-306 - Missing Authentication for Critical Function
Assigner
References
Impacted products
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T10:50:57.789Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-305120.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SICAM MMU",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.05"
            }
          ]
        },
        {
          "product": "SICAM SGU",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "SICAM T",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.18"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SICAM MMU (All versions \u003c V2.05), SICAM SGU (All versions), SICAM T (All versions \u003c V2.18). An attacker with access to the device\u0027s web server might be able to execute administrative commands without authentication."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-306",
              "description": "CWE-306: Missing Authentication for Critical Function",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-07-14T13:18:04.000Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-305120.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2020-10038",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SICAM MMU",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2.05"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SICAM SGU",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SICAM T",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2.18"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens AG"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in SICAM MMU (All versions \u003c V2.05), SICAM SGU (All versions), SICAM T (All versions \u003c V2.18). An attacker with access to the device\u0027s web server might be able to execute administrative commands without authentication."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-306: Missing Authentication for Critical Function"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-305120.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-305120.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2020-10038",
    "datePublished": "2020-07-14T13:18:04.000Z",
    "dateReserved": "2020-03-04T00:00:00.000Z",
    "dateUpdated": "2024-08-04T10:50:57.789Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-10044 (GCVE-0-2020-10044)

Vulnerability from cvelistv5 – Published: 2020-07-14 13:18 – Updated: 2024-08-04 10:50
VLAI
Summary
A vulnerability has been identified in SICAM MMU (All versions < V2.05), SICAM SGU (All versions), SICAM T (All versions < V2.18). An attacker with access to the network could be able to install specially crafted firmware to the device.
Severity
No CVSS data available.
CWE
  • CWE-306 - Missing Authentication for Critical Function
Assigner
References
Impacted products
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T10:50:57.807Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-305120.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SICAM MMU",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.05"
            }
          ]
        },
        {
          "product": "SICAM SGU",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "SICAM T",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.18"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SICAM MMU (All versions \u003c V2.05), SICAM SGU (All versions), SICAM T (All versions \u003c V2.18). An attacker with access to the network could be able to install specially crafted firmware to the device."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-306",
              "description": "CWE-306: Missing Authentication for Critical Function",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-07-14T13:18:05.000Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-305120.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2020-10044",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SICAM MMU",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2.05"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SICAM SGU",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SICAM T",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V2.18"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens AG"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in SICAM MMU (All versions \u003c V2.05), SICAM SGU (All versions), SICAM T (All versions \u003c V2.18). An attacker with access to the network could be able to install specially crafted firmware to the device."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-306: Missing Authentication for Critical Function"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-305120.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-305120.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2020-10044",
    "datePublished": "2020-07-14T13:18:05.000Z",
    "dateReserved": "2020-03-04T00:00:00.000Z",
    "dateUpdated": "2024-08-04T10:50:57.807Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-10124 (GCVE-0-2020-10124)

Vulnerability from cvelistv5 – Published: 2020-08-21 20:30 – Updated: 2025-11-04 19:12
VLAI
Summary
NCR SelfServ ATMs running APTRA XFS 05.01.00 do not encrypt, authenticate, or verify the integrity of messages between the BNA and the host computer, which could allow an attacker with physical access to the internal components of the ATM to execute arbitrary code, including code that enables the attacker to commit deposit forgery.
Severity
No CVSS data available.
CWE
  • CWE-353 - Missing Support for Integrity Check
  • CWE-306 - Missing Authentication for Critical Function
  • CWE-311 - Missing Encryption of Sensitive Data
Assigner
References
Impacted products
Vendor Product Version
NCR SelfServ ATM Affected: APTRA XFS 05.01.00
Create a notification for this product.
Date Public
2020-08-20 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2025-11-04T19:12:02.183Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://kb.cert.org/vuls/id/815655"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.ncr.com/content/dam/ncrcom/content-type/documents/NCR_Security_Alert-2018-13_APTRA_XFS_"
          },
          {
            "url": "https://www.kb.cert.org/vuls/id/815655"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SelfServ ATM",
          "vendor": "NCR",
          "versions": [
            {
              "status": "affected",
              "version": "APTRA XFS  05.01.00"
            }
          ]
        }
      ],
      "datePublic": "2020-08-20T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "NCR SelfServ ATMs running APTRA XFS 05.01.00 do not encrypt, authenticate, or verify the integrity of messages between the BNA and the host computer, which could allow an attacker with physical access to the internal components of the ATM to execute arbitrary code, including code that enables the attacker to commit deposit forgery."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-353",
              "description": "CWE-353 Missing Support for Integrity Check",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-306",
              "description": "CWE-306 Missing Authentication for Critical Function",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-311",
              "description": "CWE-311 Missing Encryption of Sensitive Data",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-08-21T20:30:39.000Z",
        "orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
        "shortName": "certcc"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://kb.cert.org/vuls/id/815655"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.ncr.com/content/dam/ncrcom/content-type/documents/NCR_Security_Alert-2018-13_APTRA_XFS_"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cert@cert.org",
          "DATE_PUBLIC": "2020-08-20T16:34:00.000Z",
          "ID": "CVE-2020-10124",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SelfServ ATM",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_name": "APTRA XFS",
                            "version_value": "05.01.00"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "NCR"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "NCR SelfServ ATMs running APTRA XFS 05.01.00 do not encrypt, authenticate, or verify the integrity of messages between the BNA and the host computer, which could allow an attacker with physical access to the internal components of the ATM to execute arbitrary code, including code that enables the attacker to commit deposit forgery."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-353 Missing Support for Integrity Check"
                }
              ]
            },
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-306 Missing Authentication for Critical Function"
                }
              ]
            },
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-311 Missing Encryption of Sensitive Data"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://kb.cert.org/vuls/id/815655",
              "refsource": "MISC",
              "url": "https://kb.cert.org/vuls/id/815655"
            },
            {
              "name": "https://www.ncr.com/content/dam/ncrcom/content-type/documents/NCR_Security_Alert-2018-13_APTRA_XFS_",
              "refsource": "MISC",
              "url": "https://www.ncr.com/content/dam/ncrcom/content-type/documents/NCR_Security_Alert-2018-13_APTRA_XFS_"
            }
          ]
        },
        "source": {
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
    "assignerShortName": "certcc",
    "cveId": "CVE-2020-10124",
    "datePublished": "2020-08-21T20:30:39.977Z",
    "dateReserved": "2020-03-05T00:00:00.000Z",
    "dateUpdated": "2025-11-04T19:12:02.183Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2020-10265 (GCVE-0-2020-10265)

Vulnerability from cvelistv5 – Published: 2020-04-06 12:08 – Updated: 2024-09-17 03:07
VLAI
Title
RVD#1443: UR dashboard server enables unauthenticated remote control of core robot functions
Summary
Universal Robots Robot Controllers Version CB2 SW Version 1.4 upwards, CB3 SW Version 3.0 and upwards, e-series SW Version 5.0 and upwards expose a service called DashBoard server at port 29999 that allows for control over core robot functions like starting/stopping programs, shutdown, reset safety and more. The DashBoard server is not protected by any kind of authentication or authorization.
CWE
  • CWE-306 - (Missing Authentication for Critical Function)
Assigner
References
Impacted products
Date Public
2020-04-04 00:00
Credits
Bernhard Dieber, Benjamin Breiling (and many others)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T10:58:39.935Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.universal-robots.com/how-tos-and-faqs/how-to/ur-how-tos/real-time-data-exchange-rtde-guide/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Universal Robots Robot Controllers CB 2, CB3, e-series",
          "vendor": "Universal Robots",
          "versions": [
            {
              "status": "affected",
              "version": "unspecified"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Bernhard Dieber, Benjamin Breiling (and many others)"
        }
      ],
      "datePublic": "2020-04-04T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "Universal Robots Robot Controllers Version CB2 SW Version 1.4 upwards, CB3 SW Version 3.0 and upwards, e-series SW Version 5.0 and upwards expose a service called DashBoard server at port 29999 that allows for control over core robot functions like starting/stopping programs, shutdown, reset safety and more. The DashBoard server is not protected by any kind of authentication or authorization."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.4,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "LOW",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:H",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-306",
              "description": "CWE-306 (Missing Authentication for Critical Function)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-04-06T12:08:40.000Z",
        "orgId": "dc524f69-879d-41dc-ab8f-724e78658a1a",
        "shortName": "Alias"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.universal-robots.com/how-tos-and-faqs/how-to/ur-how-tos/real-time-data-exchange-rtde-guide/"
        }
      ],
      "source": {
        "defect": [
          "RVD#1443"
        ],
        "discovery": "EXTERNAL"
      },
      "title": "RVD#1443: UR dashboard server enables unauthenticated remote control of core robot functions",
      "x_generator": {
        "engine": "Robot Vulnerability Database (RVD)"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@aliasrobotics.com",
          "DATE_PUBLIC": "2020-04-04T15:38:55 +00:00",
          "ID": "CVE-2020-10265",
          "STATE": "PUBLIC",
          "TITLE": "RVD#1443: UR dashboard server enables unauthenticated remote control of core robot functions"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Universal Robots Robot Controllers CB 2, CB3, e-series",
                      "version": {
                        "version_data": [
                          {
                            "version_value": ""
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Universal Robots"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "Bernhard Dieber, Benjamin Breiling (and many others)"
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Universal Robots Robot Controllers Version CB2 SW Version 1.4 upwards, CB3 SW Version 3.0 and upwards, e-series SW Version 5.0 and upwards expose a service called DashBoard server at port 29999 that allows for control over core robot functions like starting/stopping programs, shutdown, reset safety and more. The DashBoard server is not protected by any kind of authentication or authorization."
            }
          ]
        },
        "generator": {
          "engine": "Robot Vulnerability Database (RVD)"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.4,
            "baseSeverity": "critical",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:H",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-306 (Missing Authentication for Critical Function)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.universal-robots.com/how-tos-and-faqs/how-to/ur-how-tos/real-time-data-exchange-rtde-guide/",
              "refsource": "CONFIRM",
              "url": "https://www.universal-robots.com/how-tos-and-faqs/how-to/ur-how-tos/real-time-data-exchange-rtde-guide/"
            }
          ]
        },
        "source": {
          "defect": [
            "RVD#1443"
          ],
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "dc524f69-879d-41dc-ab8f-724e78658a1a",
    "assignerShortName": "Alias",
    "cveId": "CVE-2020-10265",
    "datePublished": "2020-04-06T12:08:40.665Z",
    "dateReserved": "2020-03-10T00:00:00.000Z",
    "dateUpdated": "2024-09-17T03:07:51.861Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-10272 (GCVE-0-2020-10272)

Vulnerability from cvelistv5 – Published: 2020-06-24 04:35 – Updated: 2024-09-17 01:32
VLAI
Title
RVD#2554: MiR ROS computational graph presents no authentication mechanisms
Summary
MiR100, MiR200 and other MiR robots use the Robot Operating System (ROS) default packages exposing the computational graph without any sort of authentication. This allows attackers with access to the internal wireless and wired networks to take control of the robot seamlessly. In combination with CVE-2020-10269 and CVE-2020-10271, this flaw allows malicious actors to command the robot at desire.
CWE
Assigner
References
Impacted products
Vendor Product Version
Mobile Industrial Robots A/S MiR100 Affected: v2.8.1.1 and before
Create a notification for this product.
Date Public
2020-06-24 00:00
Credits
Victor Mayoral Vilches, Alfonso Glera, Lander Usategui, Unai Ayucar, Xabier Sáez de Cámara (Alias Robotics)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T10:58:40.075Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://github.com/aliasrobotics/RVD/issues/2554"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "MiR100",
          "vendor": "Mobile Industrial Robots A/S",
          "versions": [
            {
              "status": "affected",
              "version": "v2.8.1.1 and before"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Victor Mayoral Vilches, Alfonso Glera, Lander Usategui, Unai Ayucar, Xabier S\u00e1ez de C\u00e1mara (Alias Robotics)"
        }
      ],
      "datePublic": "2020-06-24T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "MiR100, MiR200 and other MiR robots use the Robot Operating System (ROS) default packages exposing the computational graph without any sort of authentication. This allows attackers with access to the internal wireless and wired networks to take control of the robot seamlessly. In combination with CVE-2020-10269 and CVE-2020-10271, this flaw allows malicious actors to command the robot at desire."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 10,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-306",
              "description": "CWE-306",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-06-24T04:35:12.000Z",
        "orgId": "dc524f69-879d-41dc-ab8f-724e78658a1a",
        "shortName": "Alias"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://github.com/aliasrobotics/RVD/issues/2554"
        }
      ],
      "source": {
        "defect": [
          "RVD#2554"
        ],
        "discovery": "EXTERNAL"
      },
      "title": "RVD#2554: MiR ROS computational graph presents no authentication mechanisms",
      "x_generator": {
        "engine": "Robot Vulnerability Database (RVD)"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@aliasrobotics.com",
          "DATE_PUBLIC": "2020-06-24T04:32:35 +00:00",
          "ID": "CVE-2020-10272",
          "STATE": "PUBLIC",
          "TITLE": "RVD#2554: MiR ROS computational graph presents no authentication mechanisms"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "MiR100",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "v2.8.1.1 and before"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Mobile Industrial Robots A/S"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "Victor Mayoral Vilches, Alfonso Glera, Lander Usategui, Unai Ayucar, Xabier S\u00e1ez de C\u00e1mara (Alias Robotics)"
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "MiR100, MiR200 and other MiR robots use the Robot Operating System (ROS) default packages exposing the computational graph without any sort of authentication. This allows attackers with access to the internal wireless and wired networks to take control of the robot seamlessly. In combination with CVE-2020-10269 and CVE-2020-10271, this flaw allows malicious actors to command the robot at desire."
            }
          ]
        },
        "generator": {
          "engine": "Robot Vulnerability Database (RVD)"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 10,
            "baseSeverity": "critical",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-306"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/aliasrobotics/RVD/issues/2554",
              "refsource": "CONFIRM",
              "url": "https://github.com/aliasrobotics/RVD/issues/2554"
            }
          ]
        },
        "source": {
          "defect": [
            "RVD#2554"
          ],
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "dc524f69-879d-41dc-ab8f-724e78658a1a",
    "assignerShortName": "Alias",
    "cveId": "CVE-2020-10272",
    "datePublished": "2020-06-24T04:35:12.949Z",
    "dateReserved": "2020-03-10T00:00:00.000Z",
    "dateUpdated": "2024-09-17T01:32:00.119Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-10282 (GCVE-0-2020-10282)

Vulnerability from cvelistv5 – Published: 2020-07-03 14:30 – Updated: 2024-09-16 17:22
VLAI
Title
RVD#3316: No authentication in MAVLink protocol
Summary
The Micro Air Vehicle Link (MAVLink) protocol presents no authentication mechanism on its version 1.0 (nor authorization) whichs leads to a variety of attacks including identity spoofing, unauthorized access, PITM attacks and more. According to literature, version 2.0 optionally allows for package signing which mitigates this flaw. Another source mentions that MAVLink 2.0 only provides a simple authentication system based on HMAC. This implies that the flying system overall should add the same symmetric key into all devices of network. If not the case, this may cause a security issue, that if one of the devices and its symmetric key are compromised, the whole authentication system is not reliable.
CWE
Assigner
References
URL Tags
https://github.com/rligocki/Diploma_thesis_px4 x_refsource_CONFIRM
Impacted products
Vendor Product Version
unspecified MAVLink Affected: v1.0
Create a notification for this product.
Date Public
2020-07-03 00:00
Credits
None
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T10:58:39.958Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://github.com/rligocki/Diploma_thesis_px4"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "MAVLink",
          "vendor": "unspecified",
          "versions": [
            {
              "status": "affected",
              "version": "v1.0"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "None"
        }
      ],
      "datePublic": "2020-07-03T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "The Micro Air Vehicle Link (MAVLink) protocol presents no authentication mechanism on its version 1.0 (nor authorization) whichs leads to a variety of attacks including identity spoofing, unauthorized access, PITM attacks and more. According to literature, version 2.0 optionally allows for package signing which mitigates this flaw. Another source mentions that MAVLink 2.0 only provides a simple authentication system based on HMAC. This implies that the flying system overall should add the same symmetric key into all devices of network. If not the case, this may cause a security issue, that if one of the devices and its symmetric key are compromised, the whole authentication system is not reliable."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-306",
              "description": "CWE-306",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-07-03T14:30:15.000Z",
        "orgId": "dc524f69-879d-41dc-ab8f-724e78658a1a",
        "shortName": "Alias"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://github.com/rligocki/Diploma_thesis_px4"
        }
      ],
      "source": {
        "defect": [
          "RVD#3316"
        ],
        "discovery": "EXTERNAL"
      },
      "title": "RVD#3316: No authentication in MAVLink protocol",
      "x_generator": {
        "engine": "Robot Vulnerability Database (RVD)"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@aliasrobotics.com",
          "DATE_PUBLIC": "2020-07-03T14:21:35 +00:00",
          "ID": "CVE-2020-10282",
          "STATE": "PUBLIC",
          "TITLE": "RVD#3316: No authentication in MAVLink protocol"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "MAVLink",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "v1.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": ""
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "None"
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "The Micro Air Vehicle Link (MAVLink) protocol presents no authentication mechanism on its version 1.0 (nor authorization) whichs leads to a variety of attacks including identity spoofing, unauthorized access, PITM attacks and more. According to literature, version 2.0 optionally allows for package signing which mitigates this flaw. Another source mentions that MAVLink 2.0 only provides a simple authentication system based on HMAC. This implies that the flying system overall should add the same symmetric key into all devices of network. If not the case, this may cause a security issue, that if one of the devices and its symmetric key are compromised, the whole authentication system is not reliable."
            }
          ]
        },
        "generator": {
          "engine": "Robot Vulnerability Database (RVD)"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "critical",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-306"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/rligocki/Diploma_thesis_px4",
              "refsource": "CONFIRM",
              "url": "https://github.com/rligocki/Diploma_thesis_px4"
            }
          ]
        },
        "source": {
          "defect": [
            "RVD#3316"
          ],
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "dc524f69-879d-41dc-ab8f-724e78658a1a",
    "assignerShortName": "Alias",
    "cveId": "CVE-2020-10282",
    "datePublished": "2020-07-03T14:30:15.587Z",
    "dateReserved": "2020-03-10T00:00:00.000Z",
    "dateUpdated": "2024-09-16T17:22:38.711Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-10605 (GCVE-0-2020-10605)

Vulnerability from cvelistv5 – Published: 2020-07-17 21:55 – Updated: 2024-09-17 02:51
VLAI
Summary
Grundfos CIM 500 before v06.16.00 responds to unauthenticated requests for password storage files.
Severity
No CVSS data available.
CWE
  • CWE-306 - MISSING AUTHENTICATION FOR CRITICAL FUNCTION CWE-306
Assigner
References
Impacted products
Vendor Product Version
Grundfos CIM 500 Affected: before v06.16.00
Create a notification for this product.
Date Public
2020-07-07 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T11:06:09.938Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-189-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "CIM 500",
          "vendor": "Grundfos",
          "versions": [
            {
              "status": "affected",
              "version": "before v06.16.00"
            }
          ]
        }
      ],
      "datePublic": "2020-07-07T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "Grundfos CIM 500 before v06.16.00 responds to unauthenticated requests for password storage files."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-306",
              "description": "MISSING AUTHENTICATION FOR CRITICAL FUNCTION CWE-306",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-07-17T21:55:36.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-189-01"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "DATE_PUBLIC": "2020-07-07T15:00:00.000Z",
          "ID": "CVE-2020-10605",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "CIM 500",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "before v06.16.00"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Grundfos"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Grundfos CIM 500 before v06.16.00 responds to unauthenticated requests for password storage files."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "MISSING AUTHENTICATION FOR CRITICAL FUNCTION CWE-306"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://us-cert.cisa.gov/ics/advisories/icsa-20-189-01",
              "refsource": "CONFIRM",
              "url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-189-01"
            }
          ]
        },
        "source": {
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2020-10605",
    "datePublished": "2020-07-17T21:55:36.534Z",
    "dateReserved": "2020-03-16T00:00:00.000Z",
    "dateUpdated": "2024-09-17T02:51:29.016Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

Mitigation

Phase: Architecture and Design

Description:

  • Divide the software into anonymous, normal, privileged, and administrative areas. Identify which of these areas require a proven user identity, and use a centralized authentication capability.
  • Identify all potential communication channels, or other means of interaction with the software, to ensure that all channels are appropriately protected, including those channels that are assumed to be accessible only by authorized parties. Developers sometimes perform authentication at the primary channel, but open up a secondary channel that is assumed to be private. For example, a login mechanism may be listening on one network port, but after successful authentication, it may open up a second port where it waits for the connection, but avoids authentication because it assumes that only the authenticated party will connect to the port.
  • In general, if the software or protocol allows a single session or user state to persist across multiple connections or channels, authentication and appropriate credential management need to be used throughout.
Mitigation ID: MIT-15

Phase: Architecture and Design

Description:

  • For any security checks that are performed on the client side, ensure that these checks are duplicated on the server side, in order to avoid CWE-602. Attackers can bypass the client-side checks by modifying values after the checks have been performed, or by changing the client to remove the client-side checks entirely. Then, these modified values would be submitted to the server.
Mitigation

Phase: Architecture and Design

Description:

  • Where possible, avoid implementing custom, "grow-your-own" authentication routines and consider using authentication capabilities as provided by the surrounding framework, operating system, or environment. These capabilities may avoid common weaknesses that are unique to authentication; support automatic auditing and tracking; and make it easier to provide a clear separation between authentication tasks and authorization tasks.
  • In environments such as the World Wide Web, the line between authentication and authorization is sometimes blurred. If custom authentication routines are required instead of those provided by the server, then these routines must be applied to every single page, since these pages could be requested directly.
Mitigation ID: MIT-4.5

Phase: Architecture and Design

Strategy: Libraries or Frameworks

Description:

  • Use a vetted library or framework that does not allow this weakness to occur or provides constructs that make this weakness easier to avoid.
  • For example, consider using libraries with authentication capabilities such as OpenSSL or the ESAPI Authenticator [REF-45].
Mitigation

Phases: Implementation, System Configuration, Operation

Description:

  • When storing data in the cloud (e.g., S3 buckets, Azure blobs, Google Cloud Storage, etc.), use the provider's controls to require strong authentication for users who should be allowed to access the data [REF-1297] [REF-1298] [REF-1302].
CAPEC-12: Choosing Message Identifier

This pattern of attack is defined by the selection of messages distributed via multicast or public information channels that are intended for another client by determining the parameter value assigned to that client. This attack allows the adversary to gain access to potentially privileged information, and to possibly perpetrate other attacks through the distribution means by impersonation. If the channel/message being manipulated is an input rather than output mechanism for the system, (such as a command bus), this style of attack could be used to change the adversary's identifier to more a privileged one.

CAPEC-166: Force the System to Reset Values

An attacker forces the target into a previous state in order to leverage potential weaknesses in the target dependent upon a prior configuration or state-dependent factors. Even in cases where an attacker may not be able to directly control the configuration of the targeted application, they may be able to reset the configuration to a prior state since many applications implement reset functions.

CAPEC-216: Communication Channel Manipulation

An adversary manipulates a setting or parameter on communications channel in order to compromise its security. This can result in information exposure, insertion/removal of information from the communications stream, and/or potentially system compromise.

CAPEC-36: Using Unpublished Interfaces or Functionality

An adversary searches for and invokes interfaces or functionality that the target system designers did not intend to be publicly available. If interfaces fail to authenticate requests, the attacker may be able to invoke functionality they are not authorized for.

CAPEC-62: Cross Site Request Forgery

An attacker crafts malicious web links and distributes them (via web pages, email, etc.), typically in a targeted manner, hoping to induce users to click on the link and execute the malicious action against some third-party application. If successful, the action embedded in the malicious link will be processed and accepted by the targeted application with the users' privilege level. This type of attack leverages the persistence and implicit trust placed in user session cookies by many web applications today. In such an architecture, once the user authenticates to an application and a session cookie is created on the user's system, all following transactions for that session are authenticated using that cookie including potential actions initiated by an attacker and simply "riding" the existing session cookie.

Back to CWE stats page