CWE-287
Improper Authentication
When an actor claims to have a given identity, the product does not prove or insufficiently proves that the claim is correct.
CVE-2020-16102 (GCVE-0-2020-16102)
Vulnerability from cvelistv5 – Published: 2020-12-14 19:26 – Updated: 2024-08-04 13:37- CWE-287 - Improper Authentication
| URL | Tags |
|---|---|
| https://security.gallagher.com/Security-Advisorie… | x_refsource_MISC |
| Vendor | Product | Version | |
|---|---|---|---|
| Gallagher | Command Centre |
Affected:
unspecified , ≤ 7.90
(custom)
Affected: 8.30 , < 8.30.1299(MR2) (custom) Affected: 8.20 , < 8.20.1218(MR4) (custom) Affected: 8.10 , < 8.10.1253(MR6) (custom) Affected: 8.00 , < 8.00.1252(MR7) (custom) |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T13:37:53.544Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://security.gallagher.com/Security-Advisories/CVE-2020-16102"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Command Centre",
"vendor": "Gallagher",
"versions": [
{
"lessThanOrEqual": "7.90",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
},
{
"lessThan": "8.30.1299(MR2)",
"status": "affected",
"version": "8.30",
"versionType": "custom"
},
{
"lessThan": "8.20.1218(MR4)",
"status": "affected",
"version": "8.20",
"versionType": "custom"
},
{
"lessThan": "8.10.1253(MR6)",
"status": "affected",
"version": "8.10",
"versionType": "custom"
},
{
"lessThan": "8.00.1252(MR7)",
"status": "affected",
"version": "8.00",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Improper Authentication vulnerability in Gallagher Command Centre Server allows an unauthenticated remote attacker to create items with invalid configuration, potentially causing the server to crash and fail to restart. This issue affects: Gallagher Command Centre 8.30 versions prior to 8.30.1299(MR2); 8.20 versions prior to 8.20.1218(MR4); 8.10 versions prior to 8.10.1253(MR6); 8.00 versions prior to 8.00.1252(MR7); version 7.90 and prior versions."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-287",
"description": "CWE-287 Improper Authentication",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-12-15T21:29:13.000Z",
"orgId": "0c426f27-3ee1-4eff-be88-288d5a1822bc",
"shortName": "Gallagher"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://security.gallagher.com/Security-Advisories/CVE-2020-16102"
}
],
"source": {
"discovery": "INTERNAL"
},
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "disclosures@gallagher.com",
"ID": "CVE-2020-16102",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Command Centre",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "8.30",
"version_value": "8.30.1299(MR2)"
},
{
"version_affected": "\u003c",
"version_name": "8.20",
"version_value": "8.20.1218(MR4)"
},
{
"version_affected": "\u003c",
"version_name": "8.10",
"version_value": "8.10.1253(MR6)"
},
{
"version_affected": "\u003c",
"version_name": "8.00",
"version_value": "8.00.1252(MR7)"
},
{
"version_affected": "\u003c=",
"version_value": "7.90"
}
]
}
}
]
},
"vendor_name": "Gallagher"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Improper Authentication vulnerability in Gallagher Command Centre Server allows an unauthenticated remote attacker to create items with invalid configuration, potentially causing the server to crash and fail to restart. This issue affects: Gallagher Command Centre 8.30 versions prior to 8.30.1299(MR2); 8.20 versions prior to 8.20.1218(MR4); 8.10 versions prior to 8.10.1253(MR6); 8.00 versions prior to 8.00.1252(MR7); version 7.90 and prior versions."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-287 Improper Authentication"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://security.gallagher.com/Security-Advisories/CVE-2020-16102",
"refsource": "MISC",
"url": "https://security.gallagher.com/Security-Advisories/CVE-2020-16102"
}
]
},
"source": {
"discovery": "INTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "0c426f27-3ee1-4eff-be88-288d5a1822bc",
"assignerShortName": "Gallagher",
"cveId": "CVE-2020-16102",
"datePublished": "2020-12-14T19:26:18.000Z",
"dateReserved": "2020-07-28T00:00:00.000Z",
"dateUpdated": "2024-08-04T13:37:53.544Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-16222 (GCVE-0-2020-16222)
Vulnerability from cvelistv5 – Published: 2020-09-11 12:55 – Updated: 2024-08-04 13:37- CWE-287 - Improper Authentication
| URL | Tags |
|---|---|
| https://us-cert.cisa.gov/ics/advisories/icsma-20-254-01 | x_refsource_MISC |
| https://www.philips.com/productsecurity |
| Vendor | Product | Version | |
|---|---|---|---|
| Philips | Patient Information Center iX (PICiX) |
Affected:
B.02
Affected: C.02 Affected: C.03 |
|
| Philips | PerformanceBridge Focal Point |
Affected:
A.01
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T13:37:54.092Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsma-20-254-01"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.philips.com/productsecurity"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Patient Information Center iX (PICiX)",
"vendor": "Philips",
"versions": [
{
"status": "affected",
"version": "B.02"
},
{
"status": "affected",
"version": "C.02"
},
{
"status": "affected",
"version": "C.03"
}
]
},
{
"defaultStatus": "unaffected",
"product": "PerformanceBridge Focal Point",
"vendor": "Philips",
"versions": [
{
"status": "affected",
"version": "A.01"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Julian Suleder, Nils Emmerich, Birk Kauer of ERNW Research GmbH, Dr. Oliver Matula of ERNW Enno, and Rey Netzwerke GmbH reported these vulnerabilities to the Federal Office for Information Security (BSI), Germany, in the context of the BSI project ManiMed (Manipulation of medical devices), which reported these to Philips."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "In Patient Information Center iX (PICiX) Version B.02, C.02, C.03, and \nPerformanceBridge Focal Point Version A.01, when an actor claims to have\n a given identity, the software does not prove or insufficiently proves \nthe claim is correct."
}
],
"value": "In Patient Information Center iX (PICiX) Version B.02, C.02, C.03, and \nPerformanceBridge Focal Point Version A.01, when an actor claims to have\n a given identity, the software does not prove or insufficiently proves \nthe claim is correct."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-287",
"description": "CWE-287 Improper Authentication",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-12-12T20:47:05.737Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsma-20-254-01"
},
{
"url": "https://www.philips.com/productsecurity"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003ePhilips released the following versions to remediate reported vulnerabilities:\u003c/p\u003e\n\u003cul\u003e\n\u003cli\u003ePatient Information Center iX (PICiX) Version C.03\u003c/li\u003e\n\u003cli\u003ePerformanceBridge Focal Point\u003c/li\u003e\n\u003cli\u003eCertificate revocation within the system was implemented for PIC iX \nand Performance Bridge FocalPoint.\u003c/li\u003e\n\u003c/ul\u003e\n\n\u003cbr\u003e"
}
],
"value": "Philips released the following versions to remediate reported vulnerabilities:\n\n\n\n * Patient Information Center iX (PICiX) Version C.03\n\n * PerformanceBridge Focal Point\n\n * Certificate revocation within the system was implemented for PIC iX \nand Performance Bridge FocalPoint."
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "Philips Patient Monitoring Devices Improper Authentication",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eAs a mitigation to these vulnerabilities, Philips recommends the following:\u003c/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe Philips patient monitoring network is required to be physically \nor logically isolated from the hospital local area network (LAN). \nPhilips recommends using a firewall or routers that can implement access\n control lists restricting access in and out of the patient monitoring \nnetwork for only necessary ports and IP addresses. Refer to the Philips \nPatient Monitoring System Security for Clinical Networks guide for \nadditional information on \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://incenter.medical.philips.com/\"\u003eInCenter\u003c/a\u003e.\u003c/li\u003e\n\u003cli\u003eBy default, the simple certificate enrollment protocol (SCEP) \nservice is not running. When needed, the service is configured to run \nbased on the duration or the number of certificates to be assigned. One \ncertificate is default, but if a certificate is not issued, the service \nwill continue to run. Limit exposure by ensuring the SCEP service is not\n running unless it is actively being used to enroll new devices.\u003c/li\u003e\n\u003cli\u003eWhen enrolling new devices using SCEP, enter a unique challenge password of 8-12 unpredictable and randomized digits.\u003c/li\u003e\n\u003cli\u003eImplement physical security controls to prevent unauthorized login \nattempts on the PIC iX application. Servers should be kept in controlled\n locked data centers. Access to equipment at nurses\u2019 stations should be \ncontrolled and monitored.\u003c/li\u003e\n\u003cli\u003eOnly grant remote access to PIC iX servers on a must-have basis.\u003c/li\u003e\n\u003cli\u003eGrant login privileges to the bedside monitor and PIC iX application\n on a role-based, least-privilege basis, and only to trusted users.\u003c/li\u003e\n\u003c/ul\u003e\n\u003cp\u003eUsers with questions regarding their specific Philips Patient \nInformation Center (PIC iX) and/or IntelliVue patient monitor \ninstallations and new release eligibility should contact their local \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.usa.philips.com/healthcare/solutions/customer-service-solutions\"\u003ePhilips service support team, or regional service support\u003c/a\u003e, or call 1-800-722-9377.\u003c/p\u003e\n\u003cp\u003ePlease see the \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.philips.com/productsecurity\"\u003ePhilips product security website\u003c/a\u003e for the Philips advisory and the latest security information for Philips products.\u003c/p\u003e\n\n\u003cbr\u003e"
}
],
"value": "As a mitigation to these vulnerabilities, Philips recommends the following:\n\n\n\n * The Philips patient monitoring network is required to be physically \nor logically isolated from the hospital local area network (LAN). \nPhilips recommends using a firewall or routers that can implement access\n control lists restricting access in and out of the patient monitoring \nnetwork for only necessary ports and IP addresses. Refer to the Philips \nPatient Monitoring System Security for Clinical Networks guide for \nadditional information on InCenter https://incenter.medical.philips.com/ .\n\n * By default, the simple certificate enrollment protocol (SCEP) \nservice is not running. When needed, the service is configured to run \nbased on the duration or the number of certificates to be assigned. One \ncertificate is default, but if a certificate is not issued, the service \nwill continue to run. Limit exposure by ensuring the SCEP service is not\n running unless it is actively being used to enroll new devices.\n\n * When enrolling new devices using SCEP, enter a unique challenge password of 8-12 unpredictable and randomized digits.\n\n * Implement physical security controls to prevent unauthorized login \nattempts on the PIC iX application. Servers should be kept in controlled\n locked data centers. Access to equipment at nurses\u2019 stations should be \ncontrolled and monitored.\n\n * Only grant remote access to PIC iX servers on a must-have basis.\n\n * Grant login privileges to the bedside monitor and PIC iX application\n on a role-based, least-privilege basis, and only to trusted users.\n\n\n\n\nUsers with questions regarding their specific Philips Patient \nInformation Center (PIC iX) and/or IntelliVue patient monitor \ninstallations and new release eligibility should contact their local Philips service support team, or regional service support https://www.usa.philips.com/healthcare/solutions/customer-service-solutions , or call 1-800-722-9377.\n\n\nPlease see the Philips product security website https://www.philips.com/productsecurity for the Philips advisory and the latest security information for Philips products."
}
],
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2020-16222",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Philips Patient Information Center iX (PICiX), PerformanceBridge Focal Point, IntelliVue patient monitors MX100, MX400-MX850, and MP2-MP90, IntelliVue X3 and X2.",
"version": {
"version_data": [
{
"version_value": "Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, PerformanceBridge Focal Point Version A.01, IntelliVue patient monitors MX100, MX400-MX850, and MP2-MP90 Versions N and prior, IntelliVue X3 and X2 Versions N and prior."
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, PerformanceBridge Focal Point Version A.01, IntelliVue patient monitors MX100, MX400-MX850, and MP2-MP90 Versions N and prior, IntelliVue X3 and X2 Versions N and prior. When an actor claims to have a given identity, the software does not prove or insufficiently proves the claim is correct."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "IMPROPER AUTHENTICATION CWE-287"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsma-20-254-01",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/advisories/icsma-20-254-01"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2020-16222",
"datePublished": "2020-09-11T12:55:23.000Z",
"dateReserved": "2020-07-31T00:00:00.000Z",
"dateUpdated": "2024-08-04T13:37:54.092Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-16239 (GCVE-0-2020-16239)
Vulnerability from cvelistv5 – Published: 2020-08-21 12:18 – Updated: 2025-06-04 21:37| URL | Tags |
|---|---|
| https://us-cert.cisa.gov/ics/advisories/icsma-20-233-01 | x_refsource_MISC |
| https://www.philips.com/a-w/security/security-adv… |
| Vendor | Product | Version | |
|---|---|---|---|
| Philips | SureSigns VS4 |
Affected:
0 , < A.07.107
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T13:37:54.199Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsma-20-233-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "SureSigns VS4",
"vendor": "Philips",
"versions": [
{
"lessThan": "A.07.107",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Cleveland Clinic reported these vulnerabilities to Philips."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003e\nWhen an actor claims to have a given identity, \n\nPhilips SureSigns VS4, A.07.107 and prior \ndoes not prove or insufficiently proves the claim is correct.\n\n\u003c/p\u003e"
}
],
"value": "When an actor claims to have a given identity, \n\nPhilips SureSigns VS4, A.07.107 and prior \ndoes not prove or insufficiently proves the claim is correct."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-287",
"description": "CWE-287",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-06-04T21:37:16.919Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsma-20-233-01"
},
{
"url": "https://www.philips.com/a-w/security/security-advisories/product-security-2020.html#2020_archive"
}
],
"source": {
"advisory": "ICSMA-20-233-01",
"discovery": "EXTERNAL"
},
"title": "Philips SureSigns VS4 Improper Authentication",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "As a mitigation to these vulnerabilities, Philips recommends users \nchange all system passwords on the SureSigns VS4 with unique passwords \nfor each device and secure the device when not in use to prevent \nunauthorized access, as referenced in the Installation and Configuration\n Guide available on Incenter. Philips also recommends users consider \nreplacing the SureSigns VS4 device with a newer technology.\u003cbr\u003e\u003cbr\u003e\nUsers with questions regarding specific SureSigns VS4 patient monitor installations and upgrade options should contact \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.usa.philips.com/healthcare/solutions/customer-service-solutions\"\u003ePhilips service support or regional service support\u003c/a\u003e or call 1-800-722-9377.\u003cbr\u003e\u003cbr\u003e\nPlease see the \u003ca target=\"_blank\" rel=\"nofollow\" href=\"http://www.philips.com/productsecurity\"\u003ePhilips advisory\u003c/a\u003e for vulnerabilities discussed in this disclosure, and visit the \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.philips.com/productsecurity\"\u003ePhilips product security website\u003c/a\u003e for the latest security information for Philips products.\n\n\u003cbr\u003e"
}
],
"value": "As a mitigation to these vulnerabilities, Philips recommends users \nchange all system passwords on the SureSigns VS4 with unique passwords \nfor each device and secure the device when not in use to prevent \nunauthorized access, as referenced in the Installation and Configuration\n Guide available on Incenter. Philips also recommends users consider \nreplacing the SureSigns VS4 device with a newer technology.\n\n\nUsers with questions regarding specific SureSigns VS4 patient monitor installations and upgrade options should contact Philips service support or regional service support https://www.usa.philips.com/healthcare/solutions/customer-service-solutions or call 1-800-722-9377.\n\n\nPlease see the Philips advisory http://www.philips.com/productsecurity for vulnerabilities discussed in this disclosure, and visit the Philips product security website https://www.philips.com/productsecurity for the latest security information for Philips products."
}
],
"x_generator": {
"engine": "Vulnogram 0.2.0"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2020-16237",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Philips SureSigns VS4",
"version": {
"version_data": [
{
"version_value": "A.07.107 and prior"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Philips SureSigns VS4, A.07.107 and prior. The product receives input or data, but it does not validate or incorrectly validates that the input has the properties required to process the data safely and correctly."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "IMPROPER INPUT VALIDATION CWE-20"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsma-20-233-01",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/advisories/icsma-20-233-01"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2020-16239",
"datePublished": "2020-08-21T12:18:29.000Z",
"dateReserved": "2020-07-31T00:00:00.000Z",
"dateUpdated": "2025-06-04T21:37:16.919Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-1718 (GCVE-0-2020-1718)
Vulnerability from cvelistv5 – Published: 2020-05-12 20:25 – Updated: 2024-08-04 06:46| URL | Tags |
|---|---|
| https://bugzilla.redhat.com/show_bug.cgi?id=CVE-2… | x_refsource_CONFIRM |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T06:46:30.307Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://bugzilla.redhat.com/show_bug.cgi?id=CVE-2020-1718"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "keycloak",
"vendor": "Red Hat",
"versions": [
{
"status": "affected",
"version": "All versions before 8.0.0"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A flaw was found in the reset credential flow in all Keycloak versions before 8.0.0. This flaw allows an attacker to gain unauthorized access to the application."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:L/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-287",
"description": "CWE-287",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-05-12T20:25:29.000Z",
"orgId": "53f830b8-0a3f-465b-8143-3b8a9948e749",
"shortName": "redhat"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://bugzilla.redhat.com/show_bug.cgi?id=CVE-2020-1718"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "secalert@redhat.com",
"ID": "CVE-2020-1718",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "keycloak",
"version": {
"version_data": [
{
"version_value": "All versions before 8.0.0"
}
]
}
}
]
},
"vendor_name": "Red Hat"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A flaw was found in the reset credential flow in all Keycloak versions before 8.0.0. This flaw allows an attacker to gain unauthorized access to the application."
}
]
},
"impact": {
"cvss": [
[
{
"vectorString": "7.1/CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:L/A:H",
"version": "3.0"
}
]
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-287"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://bugzilla.redhat.com/show_bug.cgi?id=CVE-2020-1718",
"refsource": "CONFIRM",
"url": "https://bugzilla.redhat.com/show_bug.cgi?id=CVE-2020-1718"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "53f830b8-0a3f-465b-8143-3b8a9948e749",
"assignerShortName": "redhat",
"cveId": "CVE-2020-1718",
"datePublished": "2020-05-12T20:25:29.000Z",
"dateReserved": "2019-11-27T00:00:00.000Z",
"dateUpdated": "2024-08-04T06:46:30.307Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-1778 (GCVE-0-2020-1778)
Vulnerability from cvelistv5 – Published: 2020-11-23 15:32 – Updated: 2024-09-16 23:40- CWE-287 - Improper Authentication
| URL | Tags |
|---|---|
| https://otrs.com/release-notes/otrs-security-advi… | x_refsource_CONFIRM |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T06:46:30.909Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://otrs.com/release-notes/otrs-security-advisory-2020-16/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "OTRS",
"vendor": "OTRS AG",
"versions": [
{
"lessThanOrEqual": "8.0.9",
"status": "affected",
"version": "8.0.x",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "L\u00e1szl\u00f3 Gyaraki"
}
],
"datePublic": "2020-11-23T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "When OTRS uses multiple backends for user authentication (with LDAP), agents are able to login even if the account is set to invalid. This issue affects OTRS; 8.0.9 and prior versions."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.1,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:R/S:U/C:L/I:L/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-287",
"description": "CWE-287 Improper Authentication",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-11-23T15:32:46.000Z",
"orgId": "2e1bf29f-dc29-4ed8-830c-7b9348b6f0e8",
"shortName": "OTRS"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://otrs.com/release-notes/otrs-security-advisory-2020-16/"
}
],
"solutions": [
{
"lang": "en",
"value": "Upgrade to OTRS 8.0.10"
}
],
"source": {
"advisory": "OSA-2020-16",
"defect": [
"2020111442000202"
],
"discovery": "INTERNAL"
},
"title": "Bypassing user account validation",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "security@otrs.com",
"DATE_PUBLIC": "2020-11-23T00:00:00.000Z",
"ID": "CVE-2020-1778",
"STATE": "PUBLIC",
"TITLE": "Bypassing user account validation"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "OTRS",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_name": "8.0.x",
"version_value": "8.0.9"
}
]
}
}
]
},
"vendor_name": "OTRS AG"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "L\u00e1szl\u00f3 Gyaraki"
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "When OTRS uses multiple backends for user authentication (with LDAP), agents are able to login even if the account is set to invalid. This issue affects OTRS; 8.0.9 and prior versions."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.1,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:R/S:U/C:L/I:L/A:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-287 Improper Authentication"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://otrs.com/release-notes/otrs-security-advisory-2020-16/",
"refsource": "CONFIRM",
"url": "https://otrs.com/release-notes/otrs-security-advisory-2020-16/"
}
]
},
"solution": [
{
"lang": "en",
"value": "Upgrade to OTRS 8.0.10"
}
],
"source": {
"advisory": "OSA-2020-16",
"defect": [
"2020111442000202"
],
"discovery": "INTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "2e1bf29f-dc29-4ed8-830c-7b9348b6f0e8",
"assignerShortName": "OTRS",
"cveId": "CVE-2020-1778",
"datePublished": "2020-11-23T15:32:46.740Z",
"dateReserved": "2019-11-29T00:00:00.000Z",
"dateUpdated": "2024-09-16T23:40:42.844Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-2018 (GCVE-0-2020-2018)
Vulnerability from cvelistv5 – Published: 2020-05-13 19:07 – Updated: 2024-09-16 23:50- CWE-287 - Improper Authentication
| URL | Tags |
|---|---|
| https://security.paloaltonetworks.com/CVE-2020-2018 | x_refsource_MISC |
| Vendor | Product | Version | |
|---|---|---|---|
| Palo Alto Networks | PAN-OS |
Affected:
8.0.*
Affected: 7.1 , < 7.1.26 (custom) Affected: 8.1 , < 8.1.12 (custom) Affected: 9.0 , < 9.0.6 (custom) |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T06:54:00.524Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://security.paloaltonetworks.com/CVE-2020-2018"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "PAN-OS",
"vendor": "Palo Alto Networks",
"versions": [
{
"status": "affected",
"version": "8.0.*"
},
{
"changes": [
{
"at": "7.1.26",
"status": "unaffected"
}
],
"lessThan": "7.1.26",
"status": "affected",
"version": "7.1",
"versionType": "custom"
},
{
"changes": [
{
"at": "8.1.12",
"status": "unaffected"
}
],
"lessThan": "8.1.12",
"status": "affected",
"version": "8.1",
"versionType": "custom"
},
{
"changes": [
{
"at": "9.0.6",
"status": "unaffected"
}
],
"lessThan": "9.0.6",
"status": "affected",
"version": "9.0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "This issue was found by Ben Nott of Palo Alto Networks during internal security review."
}
],
"datePublic": "2020-05-13T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "An authentication bypass vulnerability in the Panorama context switching feature allows an attacker with network access to a Panorama\u0027s management interface to gain privileged access to managed firewalls. An attacker requires some knowledge of managed firewalls to exploit this issue. This issue does not affect Panorama configured with custom certificates authentication for communication between Panorama and managed devices. This issue affects: PAN-OS 7.1 versions earlier than 7.1.26; PAN-OS 8.1 versions earlier than 8.1.12; PAN-OS 9.0 versions earlier than 9.0.6; All versions of PAN-OS 8.0."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-287",
"description": "CWE-287 Improper Authentication",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-05-14T15:40:56.000Z",
"orgId": "d6c1279f-00f6-4ef7-9217-f89ffe703ec0",
"shortName": "palo_alto"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://security.paloaltonetworks.com/CVE-2020-2018"
}
],
"solutions": [
{
"lang": "en",
"value": "This issue is fixed in PAN-OS 7.1.26, PAN-OS 8.1.12, PAN-OS 9.0.6, and all later PAN-OS versions.\n\nUpgrading Panorama to a fixed version is sufficient to resolve the issue.\n\nPAN-OS 8.0 is now end-of-life as of October 31, 2019, and is no longer covered by our Product Security Assurance policies."
}
],
"source": {
"defect": [
"PAN-123661"
],
"discovery": "INTERNAL"
},
"timeline": [
{
"lang": "en",
"time": "2020-05-13T00:00:00.000Z",
"value": "Initial publication"
}
],
"title": "PAN-OS: Panorama authentication bypass vulnerability",
"workarounds": [
{
"lang": "en",
"value": "This issue can be completely mitigated by enabling custom certificates authentication between Panorama and managed firewalls. See https://docs.paloaltonetworks.com/panorama/8-0/panorama-admin/set-up-panorama/set-up-authentication-using-custom-certificates.html\n\nThis issue affects the management interface of PAN-OS and is strongly mitigated by following best practices for securing the PAN-OS management interface. Please review the Best Practices for Securing Administrative Access in the PAN-OS technical documentation, available at: https://docs.paloaltonetworks.com"
}
],
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "psirt@paloaltonetworks.com",
"DATE_PUBLIC": "2020-05-13T16:00:00.000Z",
"ID": "CVE-2020-2018",
"STATE": "PUBLIC",
"TITLE": "PAN-OS: Panorama authentication bypass vulnerability"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "PAN-OS",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "7.1",
"version_value": "7.1.26"
},
{
"version_affected": "\u003c",
"version_name": "8.1",
"version_value": "8.1.12"
},
{
"version_affected": "\u003c",
"version_name": "9.0",
"version_value": "9.0.6"
},
{
"version_affected": "!\u003e=",
"version_name": "7.1",
"version_value": "7.1.26"
},
{
"version_affected": "!\u003e=",
"version_name": "8.1",
"version_value": "8.1.12"
},
{
"version_affected": "!\u003e=",
"version_name": "9.0",
"version_value": "9.0.6"
},
{
"version_affected": "=",
"version_name": "8.0",
"version_value": "8.0.*"
}
]
}
}
]
},
"vendor_name": "Palo Alto Networks"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "This issue was found by Ben Nott of Palo Alto Networks during internal security review."
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An authentication bypass vulnerability in the Panorama context switching feature allows an attacker with network access to a Panorama\u0027s management interface to gain privileged access to managed firewalls. An attacker requires some knowledge of managed firewalls to exploit this issue. This issue does not affect Panorama configured with custom certificates authentication for communication between Panorama and managed devices. This issue affects: PAN-OS 7.1 versions earlier than 7.1.26; PAN-OS 8.1 versions earlier than 8.1.12; PAN-OS 9.0 versions earlier than 9.0.6; All versions of PAN-OS 8.0."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-287 Improper Authentication"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://security.paloaltonetworks.com/CVE-2020-2018",
"refsource": "MISC",
"url": "https://security.paloaltonetworks.com/CVE-2020-2018"
}
]
},
"solution": [
{
"lang": "en",
"value": "This issue is fixed in PAN-OS 7.1.26, PAN-OS 8.1.12, PAN-OS 9.0.6, and all later PAN-OS versions.\n\nUpgrading Panorama to a fixed version is sufficient to resolve the issue.\n\nPAN-OS 8.0 is now end-of-life as of October 31, 2019, and is no longer covered by our Product Security Assurance policies."
}
],
"source": {
"defect": [
"PAN-123661"
],
"discovery": "INTERNAL"
},
"timeline": [
{
"lang": "en",
"time": "2020-05-13T00:00:00.000Z",
"value": "Initial publication"
}
],
"work_around": [
{
"lang": "en",
"value": "This issue can be completely mitigated by enabling custom certificates authentication between Panorama and managed firewalls. See https://docs.paloaltonetworks.com/panorama/8-0/panorama-admin/set-up-panorama/set-up-authentication-using-custom-certificates.html\n\nThis issue affects the management interface of PAN-OS and is strongly mitigated by following best practices for securing the PAN-OS management interface. Please review the Best Practices for Securing Administrative Access in the PAN-OS technical documentation, available at: https://docs.paloaltonetworks.com"
}
]
}
}
},
"cveMetadata": {
"assignerOrgId": "d6c1279f-00f6-4ef7-9217-f89ffe703ec0",
"assignerShortName": "palo_alto",
"cveId": "CVE-2020-2018",
"datePublished": "2020-05-13T19:07:14.771Z",
"dateReserved": "2019-12-04T00:00:00.000Z",
"dateUpdated": "2024-09-16T23:50:38.279Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-24675 (GCVE-0-2020-24675)
Vulnerability from cvelistv5 – Published: 2020-12-22 21:22 – Updated: 2024-09-16 22:36- CWE-287 - Improper Authentication
| URL | Tags |
|---|---|
| https://search.abb.com/library/Download.aspx?Docu… | x_refsource_MISC |
| https://search.abb.com/library/Download.aspx?Docu… | x_refsource_MISC |
| Vendor | Product | Version | |
|---|---|---|---|
| ABB | ABB Ability™ Symphony® Plus Operations |
Affected:
unspecified , < 3.3 Service Pack 1
(custom)
Affected: unspecified , < 2.1 SP2 Rollup 2 (custom) Affected: unspecified , < 2.2 (custom) |
|
| ABB | ABB Ability™ Symphony® Plus Historian |
Affected:
unspecified , < 3.2
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T15:19:08.688Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA123980\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA123982\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "ABB Ability\u2122 Symphony\u00ae Plus Operations",
"vendor": "ABB",
"versions": [
{
"lessThan": "3.3 Service Pack 1",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
},
{
"lessThan": "2.1 SP2 Rollup 2",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
},
{
"lessThan": "2.2",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "ABB Ability\u2122 Symphony\u00ae Plus Historian",
"vendor": "ABB",
"versions": [
{
"lessThan": "3.2",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"datePublic": "2020-12-15T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "In S+ Operations and S+ History, it is possible that an unauthenticated user could inject values to the Operations History server (or standalone S+ History server) and ultimately write values to the controlled process."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-287",
"description": "CWE-287 Improper Authentication",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-12-22T21:22:05.000Z",
"orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
"shortName": "ABB"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA123980\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA123982\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
}
],
"source": {
"advisory": "2PAA123980, 2PAA123982",
"discovery": "INTERNAL"
},
"title": "Weak Authentication in Symphony Plus",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@ch.abb.com",
"DATE_PUBLIC": "2020-12-15T13:10:00.000Z",
"ID": "CVE-2020-24675",
"STATE": "PUBLIC",
"TITLE": "Weak Authentication in Symphony Plus"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "ABB Ability\u2122 Symphony\u00ae Plus Operations",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "3.3 Service Pack 1"
},
{
"version_affected": "\u003c",
"version_value": "2.1 SP2 Rollup 2"
},
{
"version_affected": "\u003c",
"version_value": "2.2"
}
]
}
},
{
"product_name": "ABB Ability\u2122 Symphony\u00ae Plus Historian",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "3.2"
}
]
}
}
]
},
"vendor_name": "ABB"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "In S+ Operations and S+ History, it is possible that an unauthenticated user could inject values to the Operations History server (or standalone S+ History server) and ultimately write values to the controlled process."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-287 Improper Authentication"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA123980\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch",
"refsource": "MISC",
"url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA123980\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
},
{
"name": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA123982\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch",
"refsource": "MISC",
"url": "https://search.abb.com/library/Download.aspx?DocumentID=2PAA123982\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
}
]
},
"source": {
"advisory": "2PAA123980, 2PAA123982",
"discovery": "INTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
"assignerShortName": "ABB",
"cveId": "CVE-2020-24675",
"datePublished": "2020-12-22T21:22:05.808Z",
"dateReserved": "2020-08-26T00:00:00.000Z",
"dateUpdated": "2024-09-16T22:36:05.721Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-25165 (GCVE-0-2020-25165)
Vulnerability from cvelistv5 – Published: 2020-11-13 15:06 – Updated: 2024-08-04 15:26- CWE-287 - IMPROPER AUTHENTICATION CWE-287
| URL | Tags |
|---|---|
| https://us-cert.cisa.gov/ics/advisories/icsma-20-317-01 | x_refsource_MISC |
| Vendor | Product | Version | |
|---|---|---|---|
| n/a | BD Alaris PC Unit and BD Alaris Systems Manager |
Affected:
BD Alaris PC Unit, Model 8015, Versions 9.33.1 and earlier and BD Alaris Systems Manager, Versions 4.33 and earlier
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T15:26:09.484Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsma-20-317-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "BD Alaris PC Unit and BD Alaris Systems Manager",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "BD Alaris PC Unit, Model 8015, Versions 9.33.1 and earlier and BD Alaris Systems Manager, Versions 4.33 and earlier"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "BD Alaris PC Unit, Model 8015, Versions 9.33.1 and earlier and BD Alaris Systems Manager, Versions 4.33 and earlier The affected products are vulnerable to a network session authentication vulnerability within the authentication process between specified versions of the BD Alaris PC Unit and the BD Alaris Systems Manager. If exploited, an attacker could perform a denial-of-service attack on the BD Alaris PC Unit by modifying the configuration headers of data in transit. A denial-of-service attack could lead to a drop in the wireless capability of the BD Alaris PC Unit, resulting in manual operation of the PC Unit."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-287",
"description": "IMPROPER AUTHENTICATION CWE-287",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-11-13T15:06:08.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsma-20-317-01"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2020-25165",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "BD Alaris PC Unit and BD Alaris Systems Manager",
"version": {
"version_data": [
{
"version_value": "BD Alaris PC Unit, Model 8015, Versions 9.33.1 and earlier and BD Alaris Systems Manager, Versions 4.33 and earlier"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "BD Alaris PC Unit, Model 8015, Versions 9.33.1 and earlier and BD Alaris Systems Manager, Versions 4.33 and earlier The affected products are vulnerable to a network session authentication vulnerability within the authentication process between specified versions of the BD Alaris PC Unit and the BD Alaris Systems Manager. If exploited, an attacker could perform a denial-of-service attack on the BD Alaris PC Unit by modifying the configuration headers of data in transit. A denial-of-service attack could lead to a drop in the wireless capability of the BD Alaris PC Unit, resulting in manual operation of the PC Unit."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "IMPROPER AUTHENTICATION CWE-287"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsma-20-317-01",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/advisories/icsma-20-317-01"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2020-25165",
"datePublished": "2020-11-13T15:06:08.000Z",
"dateReserved": "2020-09-04T00:00:00.000Z",
"dateUpdated": "2024-08-04T15:26:09.484Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-25183 (GCVE-0-2020-25183)
Vulnerability from cvelistv5 – Published: 2020-12-14 19:18 – Updated: 2025-05-22 19:34- CWE-287 - Improper Authentication
| URL | Tags |
|---|---|
| https://global.medtronic.com/xg-en/product-securi… | x_refsource_MISC |
| https://www.cisa.gov/news-events/ics-medical-advi… |
| Vendor | Product | Version | |
|---|---|---|---|
| Medtronic | Smart Model 25000 Patient Reader |
Affected:
All versions
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T15:26:09.773Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsma-20-345-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Smart Model 25000 Patient Reader",
"vendor": "Medtronic",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Sternum, based in Tel Aviv, Israel, discovered and initially reported these vulnerabilities to Medtronic."
},
{
"lang": "en",
"type": "finder",
"value": "Eric Gustafson, Sara Rampazzi, Paul Grosen, Christopher Kruegel, and Giovanni Vigna from the University of California Santa Barbara, University of Florida, and University of Michigan"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eMedtronic MyCareLink Smart 25000 contains \n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003ean authentication protocol vulnerability where the method used to authenticate between the MCL Smart Patient Reader and the Medtronic MyCareLink Smart mobile app is vulnerable to bypass. This vulnerability enables an attacker to use another mobile device or malicious application on the patient\u2019s smartphone to authenticate to the patient\u2019s Medtronic Smart Reader, fooling the device into believing it is communicating with the original Medtronic smart phone application when executed within range of Bluetooth communication.\u003c/span\u003e\n\n\u003c/p\u003e"
}
],
"value": "Medtronic MyCareLink Smart 25000 contains \n\nan authentication protocol vulnerability where the method used to authenticate between the MCL Smart Patient Reader and the Medtronic MyCareLink Smart mobile app is vulnerable to bypass. This vulnerability enables an attacker to use another mobile device or malicious application on the patient\u2019s smartphone to authenticate to the patient\u2019s Medtronic Smart Reader, fooling the device into believing it is communicating with the original Medtronic smart phone application when executed within range of Bluetooth communication."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-287",
"description": "CWE-287 Improper Authentication",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-05-22T19:34:29.069Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://global.medtronic.com/xg-en/product-security/security-bulletins/mycarelink-smart-security-vulnerability-patch.html"
},
{
"url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-20-345-01"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eA firmware update to eliminates these vulnerabilities has been developed by Medtronic and is available by updating the MyCareLink Smartapp via the associated mobile application store. Upgrading to the latest v5.2 mobile application version will ensure the Patient Reader is also updated on next use. The user\u2019s smart phone must be updated to the following operating system version for the patches to be applied: iOS 10 and above; Android 6.0 and above.\u003c/p\u003e\u003cp\u003eMedtronic has released additional \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.medtronic.com/security\"\u003epatient focused information\u003c/a\u003e: \u003c/p\u003e\u003cp\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.medtronic.com/xg-en/product-security/security-bulletins.html\"\u003ehttps://www.medtronic.com/xg-en/product-security/security-bulletins.html \u003c/a\u003e\u003c/p\u003e\n\n\u003cbr\u003e"
}
],
"value": "A firmware update to eliminates these vulnerabilities has been developed by Medtronic and is available by updating the MyCareLink Smartapp via the associated mobile application store. Upgrading to the latest v5.2 mobile application version will ensure the Patient Reader is also updated on next use. The user\u2019s smart phone must be updated to the following operating system version for the patches to be applied: iOS 10 and above; Android 6.0 and above.\n\nMedtronic has released additional patient focused information https://www.medtronic.com/security : \n\n https://www.medtronic.com/xg-en/product-security/security-bulletins.html https://www.medtronic.com/xg-en/product-security/security-bulletins.html"
}
],
"source": {
"advisory": "ICSMA-20-345-01",
"discovery": "EXTERNAL"
},
"title": "Medtronic MyCareLink Smart Improper Authentication",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eIn response to these vulnerabilities, Medtronic has applied additional controls for monitoring and responding to improper use of the MCL Smart Patient Reader:\u003c/p\u003e\u003cul\u003e\u003cli\u003eMedtronic has implemented enhanced integrity validation (EIV) technology, which provides early detection and real-time mitigation of known vulnerability exploitation attempts.\u003c/li\u003e\u003cli\u003eMedtronic has also implemented advanced detection system technology, which enables device-level logging and monitoring of all device activity and behavior.\u003c/li\u003e\u003c/ul\u003e\u003cp\u003eMedtronic recommends that users take additional defensive measures to minimize risk. Specifically, users should:\u003c/p\u003e\u003cul\u003e\u003cli\u003eMaintain good physical control over home monitors.\u003cul\u003e\u003cli\u003eThis includes only using home monitors in private environments such as a home, apartment, or otherwise physically controlled environment.\u003c/li\u003e\u003c/ul\u003e\u003c/li\u003e\u003cli\u003eUse only home monitors obtained directly from your healthcare provider or a Medtronic representative.\u003c/li\u003e\u003cli\u003ePatients should ensure that the operating system of their mobile phone is updated to the latest version of the available Android or Apple iOS operating system.\u003c/li\u003e\u003c/ul\u003e\u003cp\u003eReport any concerning behavior regarding these products to your healthcare provider or a Medtronic representative.\u003c/p\u003e\n\n\u003cbr\u003e"
}
],
"value": "In response to these vulnerabilities, Medtronic has applied additional controls for monitoring and responding to improper use of the MCL Smart Patient Reader:\n\n * Medtronic has implemented enhanced integrity validation (EIV) technology, which provides early detection and real-time mitigation of known vulnerability exploitation attempts.\n * Medtronic has also implemented advanced detection system technology, which enables device-level logging and monitoring of all device activity and behavior.\n\n\nMedtronic recommends that users take additional defensive measures to minimize risk. Specifically, users should:\n\n * Maintain good physical control over home monitors. * This includes only using home monitors in private environments such as a home, apartment, or otherwise physically controlled environment.\n\n\n\n * Use only home monitors obtained directly from your healthcare provider or a Medtronic representative.\n * Patients should ensure that the operating system of their mobile phone is updated to the latest version of the available Android or Apple iOS operating system.\n\n\nReport any concerning behavior regarding these products to your healthcare provider or a Medtronic representative."
}
],
"x_generator": {
"engine": "Vulnogram 0.2.0"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2020-25183",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Medtronic MyCareLink Smart 25000 Reader",
"version": {
"version_data": [
{
"version_value": "Smart 25000 all versions"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Medtronic MyCareLink Smart 25000 all versions contain an authentication protocol vuln where the method used to auth between MCL Smart Patient Reader and MyCareLink Smart mobile app is vulnerable to bypass. This vuln allows attacker to use other mobile device or malicious app on smartphone to auth to the patient\u2019s Smart Reader, fools the device into thinking its communicating with the actual smart phone application when executed in range of Bluetooth."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "IMPROPER AUTHENTICATION CWE-287"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsma-20-345-01",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/advisories/icsma-20-345-01"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2020-25183",
"datePublished": "2020-12-14T19:18:44.000Z",
"dateReserved": "2020-09-04T00:00:00.000Z",
"dateUpdated": "2025-05-22T19:34:29.069Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-25719 (GCVE-0-2020-25719)
Vulnerability from cvelistv5 – Published: 2022-02-18 00:00 – Updated: 2024-08-04 15:40{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T15:40:36.654Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://bugzilla.redhat.com/show_bug.cgi?id=2019732"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.samba.org/samba/security/CVE-2020-25719.html"
},
{
"name": "GLSA-202309-06",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://security.gentoo.org/glsa/202309-06"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "samba",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "samba 4.15.2, samba 4.14.10, samba 4.13.14"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A flaw was found in the way Samba, as an Active Directory Domain Controller, implemented Kerberos name-based authentication. The Samba AD DC, could become confused about the user a ticket represents if it did not strictly require a Kerberos PAC and always use the SIDs found within. The result could include total domain compromise."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-287",
"description": "CWE-287",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-09-17T08:06:50.287Z",
"orgId": "53f830b8-0a3f-465b-8143-3b8a9948e749",
"shortName": "redhat"
},
"references": [
{
"url": "https://bugzilla.redhat.com/show_bug.cgi?id=2019732"
},
{
"url": "https://www.samba.org/samba/security/CVE-2020-25719.html"
},
{
"name": "GLSA-202309-06",
"tags": [
"vendor-advisory"
],
"url": "https://security.gentoo.org/glsa/202309-06"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "53f830b8-0a3f-465b-8143-3b8a9948e749",
"assignerShortName": "redhat",
"cveId": "CVE-2020-25719",
"datePublished": "2022-02-18T00:00:00.000Z",
"dateReserved": "2020-09-16T00:00:00.000Z",
"dateUpdated": "2024-08-04T15:40:36.654Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
Mitigation
Phase: Architecture and Design
Strategy: Libraries or Frameworks
Description:
- Use an authentication framework or library such as the OWASP ESAPI Authentication feature.
CAPEC-114: Authentication Abuse
An attacker obtains unauthorized access to an application, service or device either through knowledge of the inherent weaknesses of an authentication mechanism, or by exploiting a flaw in the authentication scheme's implementation. In such an attack an authentication mechanism is functioning but a carefully controlled sequence of events causes the mechanism to grant access to the attacker.
CAPEC-115: Authentication Bypass
An attacker gains access to application, service, or device with the privileges of an authorized or privileged user by evading or circumventing an authentication mechanism. The attacker is therefore able to access protected data without authentication ever having taken place.
CAPEC-151: Identity Spoofing
Identity Spoofing refers to the action of assuming (i.e., taking on) the identity of some other entity (human or non-human) and then using that identity to accomplish a goal. An adversary may craft messages that appear to come from a different principle or use stolen / spoofed authentication credentials.
CAPEC-194: Fake the Source of Data
An adversary takes advantage of improper authentication to provide data or services under a falsified identity. The purpose of using the falsified identity may be to prevent traceability of the provided data or to assume the rights granted to another individual. One of the simplest forms of this attack would be the creation of an email message with a modified "From" field in order to appear that the message was sent from someone other than the actual sender. The root of the attack (in this case the email system) fails to properly authenticate the source and this results in the reader incorrectly performing the instructed action. Results of the attack vary depending on the details of the attack, but common results include privilege escalation, obfuscation of other attacks, and data corruption/manipulation.
CAPEC-22: Exploiting Trust in Client
An attack of this type exploits vulnerabilities in client/server communication channel authentication and data integrity. It leverages the implicit trust a server places in the client, or more importantly, that which the server believes is the client. An attacker executes this type of attack by communicating directly with the server where the server believes it is communicating only with a valid client. There are numerous variations of this type of attack.
CAPEC-57: Utilizing REST's Trust in the System Resource to Obtain Sensitive Data
This attack utilizes a REST(REpresentational State Transfer)-style applications' trust in the system resources and environment to obtain sensitive data once SSL is terminated.
CAPEC-593: Session Hijacking
This type of attack involves an adversary that exploits weaknesses in an application's use of sessions in performing authentication. The adversary is able to steal or manipulate an active session and use it to gain unathorized access to the application.
CAPEC-633: Token Impersonation
An adversary exploits a weakness in authentication to create an access token (or equivalent) that impersonates a different entity, and then associates a process/thread to that that impersonated token. This action causes a downstream user to make a decision or take action that is based on the assumed identity, and not the response that blocks the adversary.
CAPEC-650: Upload a Web Shell to a Web Server
By exploiting insufficient permissions, it is possible to upload a web shell to a web server in such a way that it can be executed remotely. This shell can have various capabilities, thereby acting as a "gateway" to the underlying web server. The shell might execute at the higher permission level of the web server, providing the ability the execute malicious code at elevated levels.
CAPEC-94: Adversary in the Middle (AiTM)
An adversary targets the communication between two components (typically client and server), in order to alter or obtain data from transactions. A general approach entails the adversary placing themself within the communication channel between the two components.