CWE-287

Improper Authentication

When an actor claims to have a given identity, the product does not prove or insufficiently proves that the claim is correct.

CVE-2019-6832 (GCVE-0-2019-6832)

Vulnerability from cvelistv5 – Published: 2019-09-17 19:31 – Updated: 2024-08-04 20:31
VLAI
Summary
A CWE-287: Authentication vulnerability exists in spaceLYnk (all versions before 2.4.0) and Wiser for KNX (all versions before 2.4.0 - formerly known as homeLYnk), which could cause loss of control when an attacker bypasses the authentication.
Severity
No CVSS data available.
CWE
Assigner
References
Impacted products
Vendor Product Version
Schneider Electric SE spaceLYnk Affected: all versions before 2.4.0
Create a notification for this product.
Schneider Electric SE Wiser for KNX Affected: all versions before 2.4.0 - formerly known as homeLYnk
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T20:31:04.434Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-225-07/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "spaceLYnk",
          "vendor": "Schneider Electric SE",
          "versions": [
            {
              "status": "affected",
              "version": "all versions before 2.4.0"
            }
          ]
        },
        {
          "product": "Wiser for KNX",
          "vendor": "Schneider Electric SE",
          "versions": [
            {
              "status": "affected",
              "version": "all versions before 2.4.0 - formerly known as homeLYnk"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A CWE-287: Authentication vulnerability exists in spaceLYnk (all versions before 2.4.0) and Wiser for KNX (all versions before 2.4.0 - formerly known as homeLYnk), which could cause loss of control when an attacker bypasses the authentication."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-287",
              "description": "CWE-287: Authentication",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-09-17T19:31:14.000Z",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-225-07/"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cybersecurity@schneider-electric.com",
          "ID": "CVE-2019-6832",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "spaceLYnk",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "all versions before 2.4.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Wiser for KNX",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "all versions before 2.4.0 - formerly known as homeLYnk"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Schneider Electric SE"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A CWE-287: Authentication vulnerability exists in spaceLYnk (all versions before 2.4.0) and Wiser for KNX (all versions before 2.4.0 - formerly known as homeLYnk), which could cause loss of control when an attacker bypasses the authentication."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-287: Authentication"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.schneider-electric.com/en/download/document/SEVD-2019-225-07/",
              "refsource": "CONFIRM",
              "url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-225-07/"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2019-6832",
    "datePublished": "2019-09-17T19:31:14.000Z",
    "dateReserved": "2019-01-25T00:00:00.000Z",
    "dateUpdated": "2024-08-04T20:31:04.434Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2019-6854 (GCVE-0-2019-6854)

Vulnerability from cvelistv5 – Published: 2020-01-06 22:56 – Updated: 2024-08-04 20:31
VLAI
Summary
A CWE-287: Improper Authentication vulnerability exists in a folder within EcoStruxure Geo SCADA Expert (ClearSCADA) -with initial releases before 1 January 2019- which could cause a low privilege user to delete or modify database, setting or certificate files. Those users must have access to the file system of that operating system to exploit this vulnerability. Affected versions in current support includes ClearSCADA 2017 R3, ClearSCADA 2017 R2, and ClearSCADA 2017.
Severity
No CVSS data available.
CWE
  • CWE-287 - Improper Authentication
Assigner
References
Impacted products
Vendor Product Version
n/a EcoStruxure Geo SCADA Expert (ClearSCADA) with initial releases before 1 January 2019 (see notification for more details) Affected: EcoStruxure Geo SCADA Expert (ClearSCADA) with initial releases before 1 January 2019 (see notification for more details)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T20:31:04.395Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.se.com/ww/en/download/document/SEVD-2019-344-05/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "EcoStruxure Geo SCADA Expert (ClearSCADA) with initial releases before 1 January 2019 (see notification for more details)",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "EcoStruxure Geo SCADA Expert (ClearSCADA) with initial releases before 1 January 2019 (see notification for more details)"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A CWE-287: Improper Authentication vulnerability exists in a folder within EcoStruxure Geo SCADA Expert (ClearSCADA) -with initial releases before 1 January 2019- which could cause a low privilege user to delete or modify database, setting or certificate files. Those users must have access to the file system of that operating system to exploit this vulnerability. Affected versions in current support includes ClearSCADA 2017 R3, ClearSCADA 2017 R2, and ClearSCADA 2017."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-287",
              "description": "CWE-287: Improper Authentication",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-04-19T12:10:47.000Z",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.se.com/ww/en/download/document/SEVD-2019-344-05/"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cybersecurity@schneider-electric.com",
          "ID": "CVE-2019-6854",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "EcoStruxure Geo SCADA Expert (ClearSCADA) with initial releases before 1 January 2019 (see notification for more details)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "EcoStruxure Geo SCADA Expert (ClearSCADA) with initial releases before 1 January 2019 (see notification for more details)"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A CWE-287: Improper Authentication vulnerability exists in a folder within EcoStruxure Geo SCADA Expert (ClearSCADA) -with initial releases before 1 January 2019- which could cause a low privilege user to delete or modify database, setting or certificate files. Those users must have access to the file system of that operating system to exploit this vulnerability. Affected versions in current support includes ClearSCADA 2017 R3, ClearSCADA 2017 R2, and ClearSCADA 2017."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-287: Improper Authentication"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.se.com/ww/en/download/document/SEVD-2019-344-05/",
              "refsource": "MISC",
              "url": "https://www.se.com/ww/en/download/document/SEVD-2019-344-05/"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2019-6854",
    "datePublished": "2020-01-06T22:56:53.000Z",
    "dateReserved": "2019-01-25T00:00:00.000Z",
    "dateUpdated": "2024-08-04T20:31:04.395Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-10709 (GCVE-0-2020-10709)

Vulnerability from cvelistv5 – Published: 2021-05-27 18:46 – Updated: 2024-08-04 11:06
VLAI
Summary
A security flaw was found in Ansible Tower when requesting an OAuth2 token with an OAuth2 application. Ansible Tower uses the token to provide authentication. This flaw allows an attacker to obtain a refresh token that does not expire. The original token granted to the user still has access to Ansible Tower, which allows any user that can gain access to the token to be fully authenticated to Ansible Tower. This flaw affects Ansible Tower versions before 3.6.4 and Ansible Tower versions before 3.5.6.
Severity
No CVSS data available.
CWE
Assigner
References
Impacted products
Vendor Product Version
n/a Tower Affected: ansible_tower 3.6.4, ansible_tower 3.5.6
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T11:06:11.168Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://bugzilla.redhat.com/show_bug.cgi?id=1824033"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Tower",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "ansible_tower 3.6.4, ansible_tower 3.5.6"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A security flaw was found in Ansible Tower when requesting an OAuth2 token with an OAuth2 application. Ansible Tower uses the token to provide authentication. This flaw allows an attacker to obtain a refresh token that does not expire. The original token granted to the user still has access to Ansible Tower, which allows any user that can gain access to the token to be fully authenticated to Ansible Tower. This flaw affects Ansible Tower versions before 3.6.4 and Ansible Tower versions before 3.5.6."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-287",
              "description": "CWE-287-\u003eCWE-672-\u003eCWE-613",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-05-27T18:46:02.000Z",
        "orgId": "53f830b8-0a3f-465b-8143-3b8a9948e749",
        "shortName": "redhat"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://bugzilla.redhat.com/show_bug.cgi?id=1824033"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "secalert@redhat.com",
          "ID": "CVE-2020-10709",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Tower",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "ansible_tower 3.6.4, ansible_tower 3.5.6"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A security flaw was found in Ansible Tower when requesting an OAuth2 token with an OAuth2 application. Ansible Tower uses the token to provide authentication. This flaw allows an attacker to obtain a refresh token that does not expire. The original token granted to the user still has access to Ansible Tower, which allows any user that can gain access to the token to be fully authenticated to Ansible Tower. This flaw affects Ansible Tower versions before 3.6.4 and Ansible Tower versions before 3.5.6."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-287-\u003eCWE-672-\u003eCWE-613"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://bugzilla.redhat.com/show_bug.cgi?id=1824033",
              "refsource": "MISC",
              "url": "https://bugzilla.redhat.com/show_bug.cgi?id=1824033"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "53f830b8-0a3f-465b-8143-3b8a9948e749",
    "assignerShortName": "redhat",
    "cveId": "CVE-2020-10709",
    "datePublished": "2021-05-27T18:46:02.000Z",
    "dateReserved": "2020-03-20T00:00:00.000Z",
    "dateUpdated": "2024-08-04T11:06:11.168Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-10754 (GCVE-0-2020-10754)

Vulnerability from cvelistv5 – Published: 2020-06-08 17:16 – Updated: 2024-08-04 11:14
VLAI
Summary
It was found that nmcli, a command line interface to NetworkManager did not honour 802-1x.ca-path and 802-1x.phase2-ca-path settings, when creating a new profile. When a user connects to a network using this profile, the authentication does not happen and the connection is made insecurely.
Assigner
References
Impacted products
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T11:14:15.561Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://bugzilla.redhat.com/show_bug.cgi?id=CVE-2020-10754"
          },
          {
            "name": "FEDORA-2020-ace543feff",
            "tags": [
              "vendor-advisory",
              "x_refsource_FEDORA",
              "x_transferred"
            ],
            "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/44FTVXWKDYIAMOOP2PZMUY3D2QNWAVBZ/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "NetworkManager",
          "vendor": "[Red Hat]",
          "versions": [
            {
              "status": "affected",
              "version": "1.24.2"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "It was found that nmcli, a command line interface to NetworkManager did not honour 802-1x.ca-path and 802-1x.phase2-ca-path settings, when creating a new profile. When a user connects to a network using this profile, the authentication does not happen and the connection is made insecurely."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 4.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-287",
              "description": "CWE-287",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-306",
              "description": "CWE-306",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-06-14T18:06:11.000Z",
        "orgId": "53f830b8-0a3f-465b-8143-3b8a9948e749",
        "shortName": "redhat"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://bugzilla.redhat.com/show_bug.cgi?id=CVE-2020-10754"
        },
        {
          "name": "FEDORA-2020-ace543feff",
          "tags": [
            "vendor-advisory",
            "x_refsource_FEDORA"
          ],
          "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/44FTVXWKDYIAMOOP2PZMUY3D2QNWAVBZ/"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "secalert@redhat.com",
          "ID": "CVE-2020-10754",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "NetworkManager",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "1.24.2"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "[Red Hat]"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "It was found that nmcli, a command line interface to NetworkManager did not honour 802-1x.ca-path and 802-1x.phase2-ca-path settings, when creating a new profile. When a user connects to a network using this profile, the authentication does not happen and the connection is made insecurely."
            }
          ]
        },
        "impact": {
          "cvss": [
            [
              {
                "vectorString": "4.3/CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N",
                "version": "3.0"
              }
            ]
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-287"
                }
              ]
            },
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-306"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://bugzilla.redhat.com/show_bug.cgi?id=CVE-2020-10754",
              "refsource": "CONFIRM",
              "url": "https://bugzilla.redhat.com/show_bug.cgi?id=CVE-2020-10754"
            },
            {
              "name": "FEDORA-2020-ace543feff",
              "refsource": "FEDORA",
              "url": "https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/44FTVXWKDYIAMOOP2PZMUY3D2QNWAVBZ/"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "53f830b8-0a3f-465b-8143-3b8a9948e749",
    "assignerShortName": "redhat",
    "cveId": "CVE-2020-10754",
    "datePublished": "2020-06-08T17:16:26.000Z",
    "dateReserved": "2020-03-20T00:00:00.000Z",
    "dateUpdated": "2024-08-04T11:14:15.561Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-10888 (GCVE-0-2020-10888)

Vulnerability from cvelistv5 – Published: 2020-03-25 19:15 – Updated: 2024-08-04 11:14
VLAI
Summary
This vulnerability allows remote attackers to bypass authentication on affected installations of TP-Link Archer A7 Firmware Ver: 190726 AC1750 routers. Authentication is not required to exploit this vulnerability. The specific flaw exists within the handling of SSH port forwarding requests during initial setup. The issue results from the lack of proper authentication prior to establishing SSH port forwarding rules. An attacker can leverage this vulnerability to escalate privileges to resources normally protected from the WAN interface. Was ZDI-CAN-9664.
CWE
  • CWE-287 - Improper Authentication
Assigner
zdi
References
Impacted products
Vendor Product Version
TP-Link Archer A7 Affected: Firmware Ver: 190726
Create a notification for this product.
Credits
F-Secure Labs - Mark Barnes, Toby Drew, Max Van Amerongen, and James Loureiro
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T11:14:15.895Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.zerodayinitiative.com/advisories/ZDI-20-340/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Archer A7",
          "vendor": "TP-Link",
          "versions": [
            {
              "status": "affected",
              "version": "Firmware Ver: 190726"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "F-Secure Labs - Mark Barnes, Toby Drew, Max Van Amerongen, and James Loureiro"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "This vulnerability allows remote attackers to bypass authentication on affected installations of TP-Link Archer A7 Firmware Ver: 190726 AC1750 routers. Authentication is not required to exploit this vulnerability. The specific flaw exists within the handling of SSH port forwarding requests during initial setup. The issue results from the lack of proper authentication prior to establishing SSH port forwarding rules. An attacker can leverage this vulnerability to escalate privileges to resources normally protected from the WAN interface. Was ZDI-CAN-9664."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.9,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:N",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-287",
              "description": "CWE-287: Improper Authentication",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-03-25T19:15:26.000Z",
        "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
        "shortName": "zdi"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.zerodayinitiative.com/advisories/ZDI-20-340/"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "zdi-disclosures@trendmicro.com",
          "ID": "CVE-2020-10888",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Archer A7",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Firmware Ver: 190726"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "TP-Link"
              }
            ]
          }
        },
        "credit": "F-Secure Labs - Mark Barnes, Toby Drew, Max Van Amerongen, and James Loureiro",
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "This vulnerability allows remote attackers to bypass authentication on affected installations of TP-Link Archer A7 Firmware Ver: 190726 AC1750 routers. Authentication is not required to exploit this vulnerability. The specific flaw exists within the handling of SSH port forwarding requests during initial setup. The issue results from the lack of proper authentication prior to establishing SSH port forwarding rules. An attacker can leverage this vulnerability to escalate privileges to resources normally protected from the WAN interface. Was ZDI-CAN-9664."
            }
          ]
        },
        "impact": {
          "cvss": {
            "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:N",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-287: Improper Authentication"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.zerodayinitiative.com/advisories/ZDI-20-340/",
              "refsource": "MISC",
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-20-340/"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
    "assignerShortName": "zdi",
    "cveId": "CVE-2020-10888",
    "datePublished": "2020-03-25T19:15:26.000Z",
    "dateReserved": "2020-03-24T00:00:00.000Z",
    "dateUpdated": "2024-08-04T11:14:15.895Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-10916 (GCVE-0-2020-10916)

Vulnerability from cvelistv5 – Published: 2020-05-07 22:20 – Updated: 2024-08-04 11:14
VLAI
Summary
This vulnerability allows network-adjacent attackers to escalate privileges on affected installations of TP-Link TL-WA855RE Firmware Ver: 855rev4-up-ver1-0-1-P1[20191213-rel60361] Wi-Fi extenders. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed. The specific flaw exists within the first-time setup process. The issue results from the lack of proper validation on first-time setup requests. An attacker can leverage this vulnerability to reset the password for the Admin account and execute code in the context of the device. Was ZDI-CAN-10003.
CWE
  • CWE-287 - Improper Authentication
Assigner
zdi
References
Impacted products
Vendor Product Version
TP-Link TL-WA855RE Affected: Firmware Ver: 855rev4-up-ver1-0-1-P1[20191213-rel60361]
Create a notification for this product.
Credits
Anonymous
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T11:14:15.896Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.zerodayinitiative.com/advisories/ZDI-20-553/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "TL-WA855RE",
          "vendor": "TP-Link",
          "versions": [
            {
              "status": "affected",
              "version": "Firmware Ver: 855rev4-up-ver1-0-1-P1[20191213-rel60361]"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Anonymous"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "This vulnerability allows network-adjacent attackers to escalate privileges on affected installations of TP-Link TL-WA855RE Firmware Ver: 855rev4-up-ver1-0-1-P1[20191213-rel60361] Wi-Fi extenders. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed. The specific flaw exists within the first-time setup process. The issue results from the lack of proper validation on first-time setup requests. An attacker can leverage this vulnerability to reset the password for the Admin account and execute code in the context of the device. Was ZDI-CAN-10003."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-287",
              "description": "CWE-287: Improper Authentication",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-05-07T22:20:12.000Z",
        "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
        "shortName": "zdi"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.zerodayinitiative.com/advisories/ZDI-20-553/"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "zdi-disclosures@trendmicro.com",
          "ID": "CVE-2020-10916",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "TL-WA855RE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Firmware Ver: 855rev4-up-ver1-0-1-P1[20191213-rel60361]"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "TP-Link"
              }
            ]
          }
        },
        "credit": "Anonymous",
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "This vulnerability allows network-adjacent attackers to escalate privileges on affected installations of TP-Link TL-WA855RE Firmware Ver: 855rev4-up-ver1-0-1-P1[20191213-rel60361] Wi-Fi extenders. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed. The specific flaw exists within the first-time setup process. The issue results from the lack of proper validation on first-time setup requests. An attacker can leverage this vulnerability to reset the password for the Admin account and execute code in the context of the device. Was ZDI-CAN-10003."
            }
          ]
        },
        "impact": {
          "cvss": {
            "vectorString": "CVSS:3.0/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-287: Improper Authentication"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.zerodayinitiative.com/advisories/ZDI-20-553/",
              "refsource": "MISC",
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-20-553/"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
    "assignerShortName": "zdi",
    "cveId": "CVE-2020-10916",
    "datePublished": "2020-05-07T22:20:12.000Z",
    "dateReserved": "2020-03-24T00:00:00.000Z",
    "dateUpdated": "2024-08-04T11:14:15.896Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-10918 (GCVE-0-2020-10918)

Vulnerability from cvelistv5 – Published: 2020-07-23 15:35 – Updated: 2024-08-04 11:14
VLAI
Summary
This vulnerability allows remote attackers to bypass authentication on affected installations of C-MORE HMI EA9 Firmware version 6.52 touch screen panels. Authentication is not required to exploit this vulnerability. The specific flaw exists within the authentication mechanism. The issue is due to insufficient authentication on post-authentication requests. An attacker can leverage this vulnerability to escalate privileges to resources normally protected from unauthenticated users. Was ZDI-CAN-10182.
CWE
  • CWE-287 - Improper Authentication
Assigner
zdi
References
Impacted products
Vendor Product Version
C-MORE HMI EA9 Affected: Firmware version 6.52
Create a notification for this product.
Credits
Anonymous
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T11:14:15.682Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.zerodayinitiative.com/advisories/ZDI-20-805/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "HMI EA9",
          "vendor": "C-MORE",
          "versions": [
            {
              "status": "affected",
              "version": "Firmware version 6.52"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Anonymous"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "This vulnerability allows remote attackers to bypass authentication on affected installations of C-MORE HMI EA9 Firmware version 6.52 touch screen panels. Authentication is not required to exploit this vulnerability. The specific flaw exists within the authentication mechanism. The issue is due to insufficient authentication on post-authentication requests. An attacker can leverage this vulnerability to escalate privileges to resources normally protected from unauthenticated users. Was ZDI-CAN-10182."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-287",
              "description": "CWE-287: Improper Authentication",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-07-23T15:35:18.000Z",
        "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
        "shortName": "zdi"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.zerodayinitiative.com/advisories/ZDI-20-805/"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "zdi-disclosures@trendmicro.com",
          "ID": "CVE-2020-10918",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "HMI EA9",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Firmware version 6.52"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "C-MORE"
              }
            ]
          }
        },
        "credit": "Anonymous",
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "This vulnerability allows remote attackers to bypass authentication on affected installations of C-MORE HMI EA9 Firmware version 6.52 touch screen panels. Authentication is not required to exploit this vulnerability. The specific flaw exists within the authentication mechanism. The issue is due to insufficient authentication on post-authentication requests. An attacker can leverage this vulnerability to escalate privileges to resources normally protected from unauthenticated users. Was ZDI-CAN-10182."
            }
          ]
        },
        "impact": {
          "cvss": {
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-287: Improper Authentication"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.zerodayinitiative.com/advisories/ZDI-20-805/",
              "refsource": "MISC",
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-20-805/"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
    "assignerShortName": "zdi",
    "cveId": "CVE-2020-10918",
    "datePublished": "2020-07-23T15:35:18.000Z",
    "dateReserved": "2020-03-24T00:00:00.000Z",
    "dateUpdated": "2024-08-04T11:14:15.682Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-11020 (GCVE-0-2020-11020)

Vulnerability from cvelistv5 – Published: 2020-04-29 17:35 – Updated: 2024-08-04 11:21
VLAI
Title
Authentication and extension bypass in Faye
Summary
Faye (NPM, RubyGem) versions greater than 0.5.0 and before 1.0.4, 1.1.3 and 1.2.5, has the potential for authentication bypass in the extension system. The vulnerability allows any client to bypass checks put in place by server-side extensions, by appending extra segments to the message channel. It is patched in versions 1.0.4, 1.1.3 and 1.2.5.
CWE
  • CWE-287 - Improper Authentication
Assigner
References
Impacted products
Vendor Product Version
faye Faye Affected: >= 0.5.0, < 1.0.4
Affected: >= 1.1.0, < 1.1.3
Affected: >= 1.2.0, < 1.2.5
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T11:21:14.232Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://github.com/faye/faye/security/advisories/GHSA-qpg4-4w7w-2mq5"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/faye/faye/commit/65d297d341b607f3cb0b5fa6021a625a991cc30e"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Faye",
          "vendor": "faye",
          "versions": [
            {
              "status": "affected",
              "version": "\u003e= 0.5.0, \u003c 1.0.4"
            },
            {
              "status": "affected",
              "version": "\u003e= 1.1.0, \u003c 1.1.3"
            },
            {
              "status": "affected",
              "version": "\u003e= 1.2.0, \u003c 1.2.5"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Faye (NPM, RubyGem) versions greater than 0.5.0 and before 1.0.4, 1.1.3 and 1.2.5, has the potential for authentication bypass in the extension system. The vulnerability allows any client to bypass checks put in place by server-side extensions, by appending extra segments to the message channel. It is patched in versions 1.0.4, 1.1.3 and 1.2.5."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 8.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:L/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-287",
              "description": "CWE-287: Improper Authentication",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-04-29T17:35:12.000Z",
        "orgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
        "shortName": "GitHub_M"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://github.com/faye/faye/security/advisories/GHSA-qpg4-4w7w-2mq5"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/faye/faye/commit/65d297d341b607f3cb0b5fa6021a625a991cc30e"
        }
      ],
      "source": {
        "advisory": "GHSA-qpg4-4w7w-2mq5",
        "discovery": "UNKNOWN"
      },
      "title": "Authentication and extension bypass in Faye",
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "security-advisories@github.com",
          "ID": "CVE-2020-11020",
          "STATE": "PUBLIC",
          "TITLE": "Authentication and extension bypass in Faye"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Faye",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "\u003e= 0.5.0, \u003c 1.0.4"
                          },
                          {
                            "version_value": "\u003e= 1.1.0, \u003c 1.1.3"
                          },
                          {
                            "version_value": "\u003e= 1.2.0, \u003c 1.2.5"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "faye"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Faye (NPM, RubyGem) versions greater than 0.5.0 and before 1.0.4, 1.1.3 and 1.2.5, has the potential for authentication bypass in the extension system. The vulnerability allows any client to bypass checks put in place by server-side extensions, by appending extra segments to the message channel. It is patched in versions 1.0.4, 1.1.3 and 1.2.5."
            }
          ]
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 8.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:L/A:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-287: Improper Authentication"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/faye/faye/security/advisories/GHSA-qpg4-4w7w-2mq5",
              "refsource": "CONFIRM",
              "url": "https://github.com/faye/faye/security/advisories/GHSA-qpg4-4w7w-2mq5"
            },
            {
              "name": "https://github.com/faye/faye/commit/65d297d341b607f3cb0b5fa6021a625a991cc30e",
              "refsource": "MISC",
              "url": "https://github.com/faye/faye/commit/65d297d341b607f3cb0b5fa6021a625a991cc30e"
            }
          ]
        },
        "source": {
          "advisory": "GHSA-qpg4-4w7w-2mq5",
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
    "assignerShortName": "GitHub_M",
    "cveId": "CVE-2020-11020",
    "datePublished": "2020-04-29T17:35:12.000Z",
    "dateReserved": "2020-03-30T00:00:00.000Z",
    "dateUpdated": "2024-08-04T11:21:14.232Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-12035 (GCVE-0-2020-12035)

Vulnerability from cvelistv5 – Published: 2020-06-29 13:49 – Updated: 2024-08-04 11:48
VLAI
Summary
Baxter PrismaFlex all versions, PrisMax all versions prior to 3.x, The PrismaFlex device contains a hard-coded service password that provides access to biomedical information, device settings, calibration settings, and network configuration. This could allow an attacker to modify device settings and calibration.
Severity
No CVSS data available.
CWE
  • CWE-287 - IMPROPER AUTHENTICATION CWE-287
Assigner
References
Impacted products
Vendor Product Version
n/a Baxter PrismaFlex and PrisMax Affected: PrismaFlex all versions, PrisMax all versions prior to 3.x
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T11:48:57.936Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.us-cert.gov/ics/advisories/icsma-20-170-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Baxter PrismaFlex and PrisMax",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "PrismaFlex all versions, PrisMax all versions prior to 3.x"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Baxter PrismaFlex all versions, PrisMax all versions prior to 3.x, The PrismaFlex device contains a hard-coded service password that provides access to biomedical information, device settings, calibration settings, and network configuration. This could allow an attacker to modify device settings and calibration."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-287",
              "description": "IMPROPER AUTHENTICATION CWE-287",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-06-29T13:49:50.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.us-cert.gov/ics/advisories/icsma-20-170-01"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2020-12035",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Baxter PrismaFlex and PrisMax",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "PrismaFlex all versions, PrisMax all versions prior to 3.x"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Baxter PrismaFlex all versions, PrisMax all versions prior to 3.x, The PrismaFlex device contains a hard-coded service password that provides access to biomedical information, device settings, calibration settings, and network configuration. This could allow an attacker to modify device settings and calibration."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "IMPROPER AUTHENTICATION CWE-287"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.us-cert.gov/ics/advisories/icsma-20-170-01",
              "refsource": "MISC",
              "url": "https://www.us-cert.gov/ics/advisories/icsma-20-170-01"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2020-12035",
    "datePublished": "2020-06-29T13:49:50.000Z",
    "dateReserved": "2020-04-21T00:00:00.000Z",
    "dateUpdated": "2024-08-04T11:48:57.936Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-12145 (GCVE-0-2020-12145)

Vulnerability from cvelistv5 – Published: 2020-11-05 18:48 – Updated: 2024-09-16 17:07
VLAI
Title
Silver Peak Unity OrchestratorTM authentication can be subverted through manipulation of HTTP headers.
Summary
Silver Peak Unity Orchestrator versions prior to 8.9.11+, 8.10.11+, or 9.0.1+ uses HTTP headers to authenticate REST API calls from localhost. This makes it possible to log in to Orchestrator by introducing an HTTP HOST header set to 127.0.0.1 or localhost. Orchestrator instances that are hosted by customers –on-premise or in a public cloud provider –are affected by this vulnerability.
CWE
  • CVE-2020-12145
  • CWE-287 - Improper Authentication
Assigner
References
Impacted products
Vendor Product Version
Silver Peak Systems, Inc. Unity Orchestrator Affected: All versions affected prior to Silver Peak Unity Orchestrator 8.9.11+
Affected: 8.10.11+
Affected: or 9.0.1+.
Create a notification for this product.
Date Public
2020-10-31 00:00
Credits
This vulnerability was reported to Silver Peak by the security team at Realmode Labs.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T11:48:58.474Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.silver-peak.com/support/user-documentation/security-advisories"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Unity Orchestrator",
          "vendor": "Silver Peak Systems, Inc.",
          "versions": [
            {
              "status": "affected",
              "version": "All versions affected prior to Silver Peak Unity Orchestrator 8.9.11+"
            },
            {
              "status": "affected",
              "version": "8.10.11+"
            },
            {
              "status": "affected",
              "version": "or 9.0.1+."
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "This vulnerability was reported to Silver Peak by the security team at Realmode Labs."
        }
      ],
      "datePublic": "2020-10-31T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "Silver Peak Unity Orchestrator versions prior to 8.9.11+, 8.10.11+, or 9.0.1+ uses HTTP headers to authenticate REST API calls from localhost. This makes it possible to log in to Orchestrator by introducing an HTTP HOST header set to 127.0.0.1 or localhost. Orchestrator instances that are hosted by customers \u2013on-premise or in a public cloud provider \u2013are affected by this vulnerability."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 6.6,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "CVE-2020-12145",
              "lang": "en",
              "type": "text"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-287",
              "description": "CWE-287 Improper Authentication",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-11-05T18:48:31.000Z",
        "orgId": "83cc1b1a-46b0-4ac1-94f2-bbef3319bc4c",
        "shortName": "Silver Peak"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.silver-peak.com/support/user-documentation/security-advisories"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "Recommended Actions for Silver Peak Customers: Upgrade to Orchestrator 8.9.11+, 8.10.11+, or 9.0.1+."
        }
      ],
      "source": {
        "advisory": "Security Advisory 2020-10-31-01-001",
        "discovery": "EXTERNAL"
      },
      "title": "Silver Peak Unity OrchestratorTM authentication can be subverted through manipulation of HTTP headers.",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "sirt@silver-peak.com",
          "DATE_PUBLIC": "2020-10-31T16:00:00.000Z",
          "ID": "CVE-2020-12145",
          "STATE": "PUBLIC",
          "TITLE": "Silver Peak Unity OrchestratorTM authentication can be subverted through manipulation of HTTP headers."
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Unity Orchestrator",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions affected prior to Silver Peak Unity Orchestrator 8.9.11+"
                          },
                          {
                            "version_value": "8.10.11+"
                          },
                          {
                            "version_value": "or 9.0.1+."
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Silver Peak Systems, Inc."
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "This vulnerability was reported to Silver Peak by the security team at Realmode Labs."
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Silver Peak Unity Orchestrator versions prior to 8.9.11+, 8.10.11+, or 9.0.1+ uses HTTP headers to authenticate REST API calls from localhost. This makes it possible to log in to Orchestrator by introducing an HTTP HOST header set to 127.0.0.1 or localhost. Orchestrator instances that are hosted by customers \u2013on-premise or in a public cloud provider \u2013are affected by this vulnerability."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 6.6,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CVE-2020-12145"
                }
              ]
            },
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-287 Improper Authentication"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.silver-peak.com/support/user-documentation/security-advisories",
              "refsource": "MISC",
              "url": "https://www.silver-peak.com/support/user-documentation/security-advisories"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "Recommended Actions for Silver Peak Customers: Upgrade to Orchestrator 8.9.11+, 8.10.11+, or 9.0.1+."
          }
        ],
        "source": {
          "advisory": "Security Advisory 2020-10-31-01-001",
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "83cc1b1a-46b0-4ac1-94f2-bbef3319bc4c",
    "assignerShortName": "Silver Peak",
    "cveId": "CVE-2020-12145",
    "datePublished": "2020-11-05T18:48:31.021Z",
    "dateReserved": "2020-04-24T00:00:00.000Z",
    "dateUpdated": "2024-09-16T17:07:58.945Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

Mitigation

Phase: Architecture and Design

Strategy: Libraries or Frameworks

Description:

  • Use an authentication framework or library such as the OWASP ESAPI Authentication feature.
CAPEC-114: Authentication Abuse

An attacker obtains unauthorized access to an application, service or device either through knowledge of the inherent weaknesses of an authentication mechanism, or by exploiting a flaw in the authentication scheme's implementation. In such an attack an authentication mechanism is functioning but a carefully controlled sequence of events causes the mechanism to grant access to the attacker.

CAPEC-115: Authentication Bypass

An attacker gains access to application, service, or device with the privileges of an authorized or privileged user by evading or circumventing an authentication mechanism. The attacker is therefore able to access protected data without authentication ever having taken place.

CAPEC-151: Identity Spoofing

Identity Spoofing refers to the action of assuming (i.e., taking on) the identity of some other entity (human or non-human) and then using that identity to accomplish a goal. An adversary may craft messages that appear to come from a different principle or use stolen / spoofed authentication credentials.

CAPEC-194: Fake the Source of Data

An adversary takes advantage of improper authentication to provide data or services under a falsified identity. The purpose of using the falsified identity may be to prevent traceability of the provided data or to assume the rights granted to another individual. One of the simplest forms of this attack would be the creation of an email message with a modified "From" field in order to appear that the message was sent from someone other than the actual sender. The root of the attack (in this case the email system) fails to properly authenticate the source and this results in the reader incorrectly performing the instructed action. Results of the attack vary depending on the details of the attack, but common results include privilege escalation, obfuscation of other attacks, and data corruption/manipulation.

CAPEC-22: Exploiting Trust in Client

An attack of this type exploits vulnerabilities in client/server communication channel authentication and data integrity. It leverages the implicit trust a server places in the client, or more importantly, that which the server believes is the client. An attacker executes this type of attack by communicating directly with the server where the server believes it is communicating only with a valid client. There are numerous variations of this type of attack.

CAPEC-57: Utilizing REST's Trust in the System Resource to Obtain Sensitive Data

This attack utilizes a REST(REpresentational State Transfer)-style applications' trust in the system resources and environment to obtain sensitive data once SSL is terminated.

CAPEC-593: Session Hijacking

This type of attack involves an adversary that exploits weaknesses in an application's use of sessions in performing authentication. The adversary is able to steal or manipulate an active session and use it to gain unathorized access to the application.

CAPEC-633: Token Impersonation

An adversary exploits a weakness in authentication to create an access token (or equivalent) that impersonates a different entity, and then associates a process/thread to that that impersonated token. This action causes a downstream user to make a decision or take action that is based on the assumed identity, and not the response that blocks the adversary.

CAPEC-650: Upload a Web Shell to a Web Server

By exploiting insufficient permissions, it is possible to upload a web shell to a web server in such a way that it can be executed remotely. This shell can have various capabilities, thereby acting as a "gateway" to the underlying web server. The shell might execute at the higher permission level of the web server, providing the ability the execute malicious code at elevated levels.

CAPEC-94: Adversary in the Middle (AiTM)

An adversary targets the communication between two components (typically client and server), in order to alter or obtain data from transactions. A general approach entails the adversary placing themself within the communication channel between the two components.

Back to CWE stats page