CWE-122
Heap-based Buffer Overflow
A heap overflow condition is a buffer overflow, where the buffer that can be overwritten is allocated in the heap portion of memory, generally meaning that the buffer was allocated using a routine such as malloc().
CVE-2021-33000 (GCVE-0-2021-33000)
Vulnerability from cvelistv5 – Published: 2021-06-24 17:30 – Updated: 2024-08-03 23:42- CWE-122 - HEAP-BASED BUFFER OVERFLOW CWE-122
| URL | Tags |
|---|---|
| https://us-cert.cisa.gov/ics/advisories/icsa-21-173-01 | x_refsource_MISC |
| Vendor | Product | Version | |
|---|---|---|---|
| n/a | WebAccess HMI Designer |
Affected:
versions 2.1.9.95 and prior
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T23:42:19.123Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-173-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "WebAccess HMI Designer",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "versions 2.1.9.95 and prior"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Parsing a maliciously crafted project file may cause a heap-based buffer overflow, which may allow an attacker to perform arbitrary code execution. User interaction is required on the WebAccess HMI Designer (versions 2.1.9.95 and prior)."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-122",
"description": "HEAP-BASED BUFFER OVERFLOW CWE-122",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-06-24T17:30:20.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-173-01"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2021-33000",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "WebAccess HMI Designer",
"version": {
"version_data": [
{
"version_value": "versions 2.1.9.95 and prior"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Parsing a maliciously crafted project file may cause a heap-based buffer overflow, which may allow an attacker to perform arbitrary code execution. User interaction is required on the WebAccess HMI Designer (versions 2.1.9.95 and prior)."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "HEAP-BASED BUFFER OVERFLOW CWE-122"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-173-01",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-173-01"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2021-33000",
"datePublished": "2021-06-24T17:30:20.000Z",
"dateReserved": "2021-05-13T00:00:00.000Z",
"dateUpdated": "2024-08-03T23:42:19.123Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-33007 (GCVE-0-2021-33007)
Vulnerability from cvelistv5 – Published: 2021-08-30 16:29 – Updated: 2024-08-03 23:42- CWE-122 - HEAP-BASED BUFFER OVERFLOW CWE-122
| URL | Tags |
|---|---|
| https://us-cert.cisa.gov/ics/advisories/icsa-21-236-03 | x_refsource_MISC |
| Vendor | Product | Version | |
|---|---|---|---|
| n/a | Delta Electronics TPEditor |
Affected:
TPEditor: v1.98.06 and prior
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T23:42:19.138Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-236-03"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Delta Electronics TPEditor",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "TPEditor: v1.98.06 and prior"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A heap-based buffer overflow in Delta Electronics TPEditor: v1.98.06 and prior may be exploited by processing a specially crafted project file. Successful exploitation of this vulnerability may allow an attacker to execute arbitrary code."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-122",
"description": "HEAP-BASED BUFFER OVERFLOW CWE-122",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-08-30T16:29:39.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-236-03"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2021-33007",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Delta Electronics TPEditor",
"version": {
"version_data": [
{
"version_value": "TPEditor: v1.98.06 and prior"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A heap-based buffer overflow in Delta Electronics TPEditor: v1.98.06 and prior may be exploited by processing a specially crafted project file. Successful exploitation of this vulnerability may allow an attacker to execute arbitrary code."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "HEAP-BASED BUFFER OVERFLOW CWE-122"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-236-03",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-236-03"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2021-33007",
"datePublished": "2021-08-30T16:29:39.000Z",
"dateReserved": "2021-05-13T00:00:00.000Z",
"dateUpdated": "2024-08-03T23:42:19.138Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-33023 (GCVE-0-2021-33023)
Vulnerability from cvelistv5 – Published: 2021-10-18 12:41 – Updated: 2024-09-17 03:49- CWE-122 - HEAP-BASED BUFFER OVERFLOW CWE-122
| URL | Tags |
|---|---|
| https://us-cert.cisa.gov/ics/advisories/icsa-21-285-02 | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T23:42:19.157Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-285-02"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "WebAccess",
"vendor": "Advantech",
"versions": [
{
"lessThanOrEqual": "9.02",
"status": "affected",
"version": "All",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Natnael Samson, @NattiSamson, working with Trend Micro\u2019s Zero Day Initiative, reported these vulnerabilities to CISA."
}
],
"datePublic": "2021-10-12T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Advantech WebAccess versions 9.02 and prior are vulnerable to a heap-based buffer overflow, which may allow an attacker to remotely execute code."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-122",
"description": "HEAP-BASED BUFFER OVERFLOW CWE-122",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-10-18T12:41:08.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-285-02"
}
],
"solutions": [
{
"lang": "en",
"value": "In order to address the heap-based buffer overflow vulnerability, Advantech recommends users directly add the remote access code to avoid being attacked by unknown requests. This is the remote access code established during installation of the Advantech WebAccess SCADA software (SCADA node, project node, or OPC Service) on the OPC Server computer. The access code you enter here must match the remote access code established during installation on the OPC Server. This prevents unauthorized users from accessing the OPC Server data using the Advantech WebAccess SCADA OPC Service.\n\nIf you have forgotten the remote access code using during software installation on the OPC Server node, you have two options:\n\nRe-install the Advantech WebAccess SCADA software on the OPC Server node to change it and edit it to match in your database.\nEdit the BWSERVER.INI file on the OPC Server node and edit it to match in your database using UPDATE."
}
],
"source": {
"advisory": "ICSA-21-285-02",
"discovery": "UNKNOWN"
},
"title": "Advantech WebAccess",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"DATE_PUBLIC": "2021-10-12T19:15:00.000Z",
"ID": "CVE-2021-33023",
"STATE": "PUBLIC",
"TITLE": "Advantech WebAccess"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "WebAccess",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_name": "All",
"version_value": "9.02"
}
]
}
}
]
},
"vendor_name": "Advantech"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Natnael Samson, @NattiSamson, working with Trend Micro\u2019s Zero Day Initiative, reported these vulnerabilities to CISA."
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Advantech WebAccess versions 9.02 and prior are vulnerable to a heap-based buffer overflow, which may allow an attacker to remotely execute code."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "HEAP-BASED BUFFER OVERFLOW CWE-122"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-285-02",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-285-02"
}
]
},
"solution": [
{
"lang": "en",
"value": "In order to address the heap-based buffer overflow vulnerability, Advantech recommends users directly add the remote access code to avoid being attacked by unknown requests. This is the remote access code established during installation of the Advantech WebAccess SCADA software (SCADA node, project node, or OPC Service) on the OPC Server computer. The access code you enter here must match the remote access code established during installation on the OPC Server. This prevents unauthorized users from accessing the OPC Server data using the Advantech WebAccess SCADA OPC Service.\n\nIf you have forgotten the remote access code using during software installation on the OPC Server node, you have two options:\n\nRe-install the Advantech WebAccess SCADA software on the OPC Server node to change it and edit it to match in your database.\nEdit the BWSERVER.INI file on the OPC Server node and edit it to match in your database using UPDATE."
}
],
"source": {
"advisory": "ICSA-21-285-02",
"discovery": "UNKNOWN"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2021-33023",
"datePublished": "2021-10-18T12:41:08.470Z",
"dateReserved": "2021-05-13T00:00:00.000Z",
"dateUpdated": "2024-09-17T03:49:19.278Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-34312 (GCVE-0-2021-34312)
Vulnerability from cvelistv5 – Published: 2021-07-13 11:03 – Updated: 2024-08-04 00:05- CWE-122 - Heap-based Buffer Overflow
| URL | Tags |
|---|---|
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_MISC |
| https://www.zerodayinitiative.com/advisories/ZDI-… | x_refsource_MISC |
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | JT2Go |
Affected:
All versions < V13.2
|
|
| Siemens | Teamcenter Visualization |
Affected:
All versions < V13.2
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T00:05:52.495Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-483182.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-841/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "JT2Go",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V13.2"
}
]
},
{
"product": "Teamcenter Visualization",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V13.2"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT2Go (All versions \u003c V13.2), Teamcenter Visualization (All versions \u003c V13.2). The Tiff_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing TIFF files. This could result in an out of bounds write past the fixed-length heap-based buffer. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13353)"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-122",
"description": "CWE-122: Heap-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-07-19T10:06:31.000Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-483182.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-841/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2021-34312",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "JT2Go",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V13.2"
}
]
}
},
{
"product_name": "Teamcenter Visualization",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V13.2"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in JT2Go (All versions \u003c V13.2), Teamcenter Visualization (All versions \u003c V13.2). The Tiff_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing TIFF files. This could result in an out of bounds write past the fixed-length heap-based buffer. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13353)"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-122: Heap-based Buffer Overflow"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-483182.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-483182.pdf"
},
{
"name": "https://www.zerodayinitiative.com/advisories/ZDI-21-841/",
"refsource": "MISC",
"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-841/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2021-34312",
"datePublished": "2021-07-13T11:03:29.000Z",
"dateReserved": "2021-06-08T00:00:00.000Z",
"dateUpdated": "2024-08-04T00:05:52.495Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-34313 (GCVE-0-2021-34313)
Vulnerability from cvelistv5 – Published: 2021-07-13 11:03 – Updated: 2024-08-04 00:05- CWE-122 - Heap-based Buffer Overflow
| URL | Tags |
|---|---|
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_MISC |
| https://www.zerodayinitiative.com/advisories/ZDI-… | x_refsource_MISC |
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | JT2Go |
Affected:
All versions < V13.2
|
|
| Siemens | Teamcenter Visualization |
Affected:
All versions < V13.2
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T00:05:52.563Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-483182.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-842/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "JT2Go",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V13.2"
}
]
},
{
"product": "Teamcenter Visualization",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V13.2"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT2Go (All versions \u003c V13.2), Teamcenter Visualization (All versions \u003c V13.2). The Tiff_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing TIFF files. This could result in an out of bounds write past the fixed-length heap-based buffer. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13354)"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-122",
"description": "CWE-122: Heap-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-07-19T10:06:26.000Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-483182.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-842/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2021-34313",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "JT2Go",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V13.2"
}
]
}
},
{
"product_name": "Teamcenter Visualization",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V13.2"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in JT2Go (All versions \u003c V13.2), Teamcenter Visualization (All versions \u003c V13.2). The Tiff_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing TIFF files. This could result in an out of bounds write past the fixed-length heap-based buffer. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13354)"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-122: Heap-based Buffer Overflow"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-483182.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-483182.pdf"
},
{
"name": "https://www.zerodayinitiative.com/advisories/ZDI-21-842/",
"refsource": "MISC",
"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-842/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2021-34313",
"datePublished": "2021-07-13T11:03:30.000Z",
"dateReserved": "2021-06-08T00:00:00.000Z",
"dateUpdated": "2024-08-04T00:05:52.563Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-34317 (GCVE-0-2021-34317)
Vulnerability from cvelistv5 – Published: 2021-07-13 11:03 – Updated: 2024-08-04 00:05- CWE-122 - Heap-based Buffer Overflow
| URL | Tags |
|---|---|
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_MISC |
| https://www.zerodayinitiative.com/advisories/ZDI-… | x_refsource_MISC |
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | JT2Go |
Affected:
All versions < V13.2
|
|
| Siemens | Teamcenter Visualization |
Affected:
All versions < V13.2
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T00:05:52.638Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-483182.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-853/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "JT2Go",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V13.2"
}
]
},
{
"product": "Teamcenter Visualization",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V13.2"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT2Go (All versions \u003c V13.2), Teamcenter Visualization (All versions \u003c V13.2). The BMP_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing PCX files. This could result in an out of bounds write past the fixed-length heap-based buffer. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13402)"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-122",
"description": "CWE-122: Heap-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-07-19T10:06:39.000Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-483182.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-853/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2021-34317",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "JT2Go",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V13.2"
}
]
}
},
{
"product_name": "Teamcenter Visualization",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V13.2"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in JT2Go (All versions \u003c V13.2), Teamcenter Visualization (All versions \u003c V13.2). The BMP_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing PCX files. This could result in an out of bounds write past the fixed-length heap-based buffer. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13402)"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-122: Heap-based Buffer Overflow"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-483182.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-483182.pdf"
},
{
"name": "https://www.zerodayinitiative.com/advisories/ZDI-21-853/",
"refsource": "MISC",
"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-853/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2021-34317",
"datePublished": "2021-07-13T11:03:34.000Z",
"dateReserved": "2021-06-08T00:00:00.000Z",
"dateUpdated": "2024-08-04T00:05:52.638Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-34326 (GCVE-0-2021-34326)
Vulnerability from cvelistv5 – Published: 2021-07-13 11:03 – Updated: 2024-08-04 00:05- CWE-122 - Heap-based Buffer Overflow
| URL | Tags |
|---|---|
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_MISC |
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_MISC |
| https://www.zerodayinitiative.com/advisories/ZDI-… | x_refsource_MISC |
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | JT2Go |
Affected:
All versions < V13.2
|
|
| Siemens | Solid Edge SE2021 |
Affected:
All Versions < SE2021MP5
|
|
| Siemens | Teamcenter Visualization |
Affected:
All versions < V13.2
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T00:05:52.502Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-483182.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-173615.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-864/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "JT2Go",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V13.2"
}
]
},
{
"product": "Solid Edge SE2021",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All Versions \u003c SE2021MP5"
}
]
},
{
"product": "Teamcenter Visualization",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V13.2"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT2Go (All versions \u003c V13.2), Solid Edge SE2021 (All Versions \u003c SE2021MP5), Teamcenter Visualization (All versions \u003c V13.2). The plmxmlAdapterSE70.dll library in affected applications lacks proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds write past the fixed-length heap-based buffer. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13422)"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-122",
"description": "CWE-122: Heap-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-07-19T10:06:59.000Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-483182.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-173615.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-864/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2021-34326",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "JT2Go",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V13.2"
}
]
}
},
{
"product_name": "Solid Edge SE2021",
"version": {
"version_data": [
{
"version_value": "All Versions \u003c SE2021MP5"
}
]
}
},
{
"product_name": "Teamcenter Visualization",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V13.2"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in JT2Go (All versions \u003c V13.2), Solid Edge SE2021 (All Versions \u003c SE2021MP5), Teamcenter Visualization (All versions \u003c V13.2). The plmxmlAdapterSE70.dll library in affected applications lacks proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds write past the fixed-length heap-based buffer. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13422)"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-122: Heap-based Buffer Overflow"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-483182.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-483182.pdf"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-173615.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-173615.pdf"
},
{
"name": "https://www.zerodayinitiative.com/advisories/ZDI-21-864/",
"refsource": "MISC",
"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-864/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2021-34326",
"datePublished": "2021-07-13T11:03:42.000Z",
"dateReserved": "2021-06-08T00:00:00.000Z",
"dateUpdated": "2024-08-04T00:05:52.502Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-34327 (GCVE-0-2021-34327)
Vulnerability from cvelistv5 – Published: 2021-07-13 11:03 – Updated: 2024-08-04 00:05- CWE-122 - Heap-based Buffer Overflow
| URL | Tags |
|---|---|
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_MISC |
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_MISC |
| https://www.zerodayinitiative.com/advisories/ZDI-… | x_refsource_MISC |
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | JT2Go |
Affected:
All versions < V13.2
|
|
| Siemens | Solid Edge SE2021 |
Affected:
All Versions < SE2021MP5
|
|
| Siemens | Teamcenter Visualization |
Affected:
All versions < V13.2
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T00:05:52.413Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-483182.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-173615.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-865/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "JT2Go",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V13.2"
}
]
},
{
"product": "Solid Edge SE2021",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All Versions \u003c SE2021MP5"
}
]
},
{
"product": "Teamcenter Visualization",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V13.2"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT2Go (All versions \u003c V13.2), Solid Edge SE2021 (All Versions \u003c SE2021MP5), Teamcenter Visualization (All versions \u003c V13.2). The plmxmlAdapterSE70.dll library in affected applications lacks proper validation of user-supplied data when parsing ASM files. This could result in an out of bounds write past the fixed-length heap-based buffer. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13423)"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-122",
"description": "CWE-122: Heap-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-07-19T10:06:36.000Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-483182.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-173615.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-865/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2021-34327",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "JT2Go",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V13.2"
}
]
}
},
{
"product_name": "Solid Edge SE2021",
"version": {
"version_data": [
{
"version_value": "All Versions \u003c SE2021MP5"
}
]
}
},
{
"product_name": "Teamcenter Visualization",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V13.2"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in JT2Go (All versions \u003c V13.2), Solid Edge SE2021 (All Versions \u003c SE2021MP5), Teamcenter Visualization (All versions \u003c V13.2). The plmxmlAdapterSE70.dll library in affected applications lacks proper validation of user-supplied data when parsing ASM files. This could result in an out of bounds write past the fixed-length heap-based buffer. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13423)"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-122: Heap-based Buffer Overflow"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-483182.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-483182.pdf"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-173615.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-173615.pdf"
},
{
"name": "https://www.zerodayinitiative.com/advisories/ZDI-21-865/",
"refsource": "MISC",
"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-865/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2021-34327",
"datePublished": "2021-07-13T11:03:43.000Z",
"dateReserved": "2021-06-08T00:00:00.000Z",
"dateUpdated": "2024-08-04T00:05:52.413Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-34328 (GCVE-0-2021-34328)
Vulnerability from cvelistv5 – Published: 2021-07-13 11:03 – Updated: 2024-08-04 00:05- CWE-122 - Heap-based Buffer Overflow
| URL | Tags |
|---|---|
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_MISC |
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_MISC |
| https://www.zerodayinitiative.com/advisories/ZDI-… | x_refsource_MISC |
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | JT2Go |
Affected:
All versions < V13.2
|
|
| Siemens | Solid Edge SE2021 |
Affected:
All Versions < SE2021MP5
|
|
| Siemens | Teamcenter Visualization |
Affected:
All versions < V13.2
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T00:05:52.483Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-483182.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-173615.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-866/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "JT2Go",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V13.2"
}
]
},
{
"product": "Solid Edge SE2021",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All Versions \u003c SE2021MP5"
}
]
},
{
"product": "Teamcenter Visualization",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V13.2"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT2Go (All versions \u003c V13.2), Solid Edge SE2021 (All Versions \u003c SE2021MP5), Teamcenter Visualization (All versions \u003c V13.2). The plmxmlAdapterSE70.dll library in affected applications lacks proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds write past the fixed-length heap-based buffer. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13424)"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-122",
"description": "CWE-122: Heap-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-07-19T10:07:13.000Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-483182.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-173615.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-866/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2021-34328",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "JT2Go",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V13.2"
}
]
}
},
{
"product_name": "Solid Edge SE2021",
"version": {
"version_data": [
{
"version_value": "All Versions \u003c SE2021MP5"
}
]
}
},
{
"product_name": "Teamcenter Visualization",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V13.2"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in JT2Go (All versions \u003c V13.2), Solid Edge SE2021 (All Versions \u003c SE2021MP5), Teamcenter Visualization (All versions \u003c V13.2). The plmxmlAdapterSE70.dll library in affected applications lacks proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds write past the fixed-length heap-based buffer. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13424)"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-122: Heap-based Buffer Overflow"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-483182.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-483182.pdf"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-173615.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-173615.pdf"
},
{
"name": "https://www.zerodayinitiative.com/advisories/ZDI-21-866/",
"refsource": "MISC",
"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-866/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2021-34328",
"datePublished": "2021-07-13T11:03:44.000Z",
"dateReserved": "2021-06-08T00:00:00.000Z",
"dateUpdated": "2024-08-04T00:05:52.483Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-34329 (GCVE-0-2021-34329)
Vulnerability from cvelistv5 – Published: 2021-07-13 11:03 – Updated: 2024-08-04 00:05- CWE-122 - Heap-based Buffer Overflow
| URL | Tags |
|---|---|
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_MISC |
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_MISC |
| https://www.zerodayinitiative.com/advisories/ZDI-… | x_refsource_MISC |
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | JT2Go |
Affected:
All versions < V13.2
|
|
| Siemens | Solid Edge SE2021 |
Affected:
All Versions < SE2021MP5
|
|
| Siemens | Teamcenter Visualization |
Affected:
All versions < V13.2
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T00:05:52.504Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-483182.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-173615.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-867/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "JT2Go",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V13.2"
}
]
},
{
"product": "Solid Edge SE2021",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All Versions \u003c SE2021MP5"
}
]
},
{
"product": "Teamcenter Visualization",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V13.2"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in JT2Go (All versions \u003c V13.2), Solid Edge SE2021 (All Versions \u003c SE2021MP5), Teamcenter Visualization (All versions \u003c V13.2). The plmxmlAdapterSE70.dll library in affected applications lacks proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds write past the fixed-length heap-based buffer. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13427)"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-122",
"description": "CWE-122: Heap-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-07-19T10:07:46.000Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-483182.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-173615.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-867/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2021-34329",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "JT2Go",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V13.2"
}
]
}
},
{
"product_name": "Solid Edge SE2021",
"version": {
"version_data": [
{
"version_value": "All Versions \u003c SE2021MP5"
}
]
}
},
{
"product_name": "Teamcenter Visualization",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V13.2"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in JT2Go (All versions \u003c V13.2), Solid Edge SE2021 (All Versions \u003c SE2021MP5), Teamcenter Visualization (All versions \u003c V13.2). The plmxmlAdapterSE70.dll library in affected applications lacks proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds write past the fixed-length heap-based buffer. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13427)"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-122: Heap-based Buffer Overflow"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-483182.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-483182.pdf"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-173615.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-173615.pdf"
},
{
"name": "https://www.zerodayinitiative.com/advisories/ZDI-21-867/",
"refsource": "MISC",
"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-867/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2021-34329",
"datePublished": "2021-07-13T11:03:45.000Z",
"dateReserved": "2021-06-08T00:00:00.000Z",
"dateUpdated": "2024-08-04T00:05:52.504Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
Mitigation
Phases:
Description:
- Pre-design: Use a language or compiler that performs automatic bounds checking.
Mitigation
Phase: Architecture and Design
Description:
- Use an abstraction library to abstract away risky APIs. Not a complete solution.
Mitigation ID: MIT-10
Phases: Operation, Build and Compilation
Strategy: Environment Hardening
Description:
- Use automatic buffer overflow detection mechanisms that are offered by certain compilers or compiler extensions. Examples include: the Microsoft Visual Studio /GS flag, Fedora/Red Hat FORTIFY_SOURCE GCC flag, StackGuard, and ProPolice, which provide various mechanisms including canary-based detection and range/index checking.
- D3-SFCV (Stack Frame Canary Validation) from D3FEND [REF-1334] discusses canary-based detection in detail.
Mitigation ID: MIT-11
Phases: Operation, Build and Compilation
Strategy: Environment Hardening
Description:
- Run or compile the software using features or extensions that randomly arrange the positions of a program's executable and libraries in memory. Because this makes the addresses unpredictable, it can prevent an attacker from reliably jumping to exploitable code.
- Examples include Address Space Layout Randomization (ASLR) [REF-58] [REF-60] and Position-Independent Executables (PIE) [REF-64]. Imported modules may be similarly realigned if their default memory addresses conflict with other modules, in a process known as "rebasing" (for Windows) and "prelinking" (for Linux) [REF-1332] using randomly generated addresses. ASLR for libraries cannot be used in conjunction with prelink since it would require relocating the libraries at run-time, defeating the whole purpose of prelinking.
- For more information on these techniques see D3-SAOR (Segment Address Offset Randomization) from D3FEND [REF-1335].
Mitigation
Phase: Implementation
Description:
- Implement and perform bounds checking on input.
Mitigation
Phase: Implementation
Strategy: Libraries or Frameworks
Description:
- Do not use dangerous functions such as gets. Look for their safe equivalent, which checks for the boundary.
Mitigation
Phase: Operation
Description:
- Use OS-level preventative functionality. This is not a complete solution, but it provides some defense in depth.
CAPEC-92: Forced Integer Overflow
This attack forces an integer variable to go out of range. The integer variable is often used as an offset such as size of memory allocation or similarly. The attacker would typically control the value of such variable and try to get it out of range. For instance the integer in question is incremented past the maximum possible value, it may wrap to become a very small, or negative number, therefore providing a very incorrect value which can lead to unexpected behavior. At worst the attacker can execute arbitrary code.