Common Weakness Enumeration

CWE-94

Allowed-with-Review

Improper Control of Generation of Code ('Code Injection')

Abstraction: Base · Status: Draft

The product constructs all or part of a code segment using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the syntax or behavior of the intended code segment.

8301 vulnerabilities reference this CWE, most recent first.

CVE-2022-34663 (GCVE-0-2022-34663)

Vulnerability from cvelistv5 – Published: 2022-07-12 10:07 – Updated: 2025-08-12 11:11
VLAI
Summary
A vulnerability has been identified in RUGGEDCOM i800, RUGGEDCOM i800NC, RUGGEDCOM i801, RUGGEDCOM i801NC, RUGGEDCOM i802, RUGGEDCOM i802NC, RUGGEDCOM i803, RUGGEDCOM i803NC, RUGGEDCOM M2100, RUGGEDCOM M2100F, RUGGEDCOM M2100NC, RUGGEDCOM M2200, RUGGEDCOM M2200F, RUGGEDCOM M2200NC, RUGGEDCOM M969, RUGGEDCOM M969F, RUGGEDCOM M969NC, RUGGEDCOM RMC30, RUGGEDCOM RMC30NC, RUGGEDCOM RMC8388 V4.X, RUGGEDCOM RMC8388 V5.X, RUGGEDCOM RMC8388NC V4.X, RUGGEDCOM RMC8388NC V5.X, RUGGEDCOM RP110, RUGGEDCOM RP110NC, RUGGEDCOM RS1600, RUGGEDCOM RS1600F, RUGGEDCOM RS1600FNC, RUGGEDCOM RS1600NC, RUGGEDCOM RS1600T, RUGGEDCOM RS1600TNC, RUGGEDCOM RS400, RUGGEDCOM RS400F, RUGGEDCOM RS400NC, RUGGEDCOM RS401, RUGGEDCOM RS401NC, RUGGEDCOM RS416, RUGGEDCOM RS416F, RUGGEDCOM RS416NC, RUGGEDCOM RS416NCv2 V4.X, RUGGEDCOM RS416NCv2 V5.X, RUGGEDCOM RS416P, RUGGEDCOM RS416PF, RUGGEDCOM RS416PNC, RUGGEDCOM RS416PNCv2 V4.X, RUGGEDCOM RS416PNCv2 V5.X, RUGGEDCOM RS416Pv2 V4.X, RUGGEDCOM RS416Pv2 V5.X, RUGGEDCOM RS416v2 V4.X, RUGGEDCOM RS416v2 V5.X, RUGGEDCOM RS8000, RUGGEDCOM RS8000A, RUGGEDCOM RS8000ANC, RUGGEDCOM RS8000H, RUGGEDCOM RS8000HNC, RUGGEDCOM RS8000NC, RUGGEDCOM RS8000T, RUGGEDCOM RS8000TNC, RUGGEDCOM RS900, RUGGEDCOM RS900 (32M) V4.X, RUGGEDCOM RS900 (32M) V5.X, RUGGEDCOM RS900F, RUGGEDCOM RS900G, RUGGEDCOM RS900G (32M) V4.X, RUGGEDCOM RS900G (32M) V5.X, RUGGEDCOM RS900GF, RUGGEDCOM RS900GNC, RUGGEDCOM RS900GNC(32M) V4.X, RUGGEDCOM RS900GNC(32M) V5.X, RUGGEDCOM RS900GP, RUGGEDCOM RS900GPF, RUGGEDCOM RS900GPNC, RUGGEDCOM RS900L, RUGGEDCOM RS900LNC, RUGGEDCOM RS900M-GETS-C01, RUGGEDCOM RS900M-GETS-XX, RUGGEDCOM RS900M-STND-C01, RUGGEDCOM RS900M-STND-XX, RUGGEDCOM RS900MNC-GETS-C01, RUGGEDCOM RS900MNC-GETS-XX, RUGGEDCOM RS900MNC-STND-XX, RUGGEDCOM RS900MNC-STND-XX-C01, RUGGEDCOM RS900NC, RUGGEDCOM RS900NC(32M) V4.X, RUGGEDCOM RS900NC(32M) V5.X, RUGGEDCOM RS900W, RUGGEDCOM RS910, RUGGEDCOM RS910L, RUGGEDCOM RS910LNC, RUGGEDCOM RS910NC, RUGGEDCOM RS910W, RUGGEDCOM RS920L, RUGGEDCOM RS920LNC, RUGGEDCOM RS920W, RUGGEDCOM RS930L, RUGGEDCOM RS930LNC, RUGGEDCOM RS930W, RUGGEDCOM RS940G, RUGGEDCOM RS940GF, RUGGEDCOM RS940GNC, RUGGEDCOM RS969, RUGGEDCOM RS969NC, RUGGEDCOM RSG2100, RUGGEDCOM RSG2100 (32M) V4.X, RUGGEDCOM RSG2100 (32M) V5.X, RUGGEDCOM RSG2100F, RUGGEDCOM RSG2100NC, RUGGEDCOM RSG2100NC(32M) V4.X, RUGGEDCOM RSG2100NC(32M) V5.X, RUGGEDCOM RSG2100P, RUGGEDCOM RSG2100P (32M) V4.X, RUGGEDCOM RSG2100P (32M) V5.X, RUGGEDCOM RSG2100PF, RUGGEDCOM RSG2100PNC, RUGGEDCOM RSG2100PNC (32M) V4.X, RUGGEDCOM RSG2100PNC (32M) V5.X, RUGGEDCOM RSG2200, RUGGEDCOM RSG2200F, RUGGEDCOM RSG2200NC, RUGGEDCOM RSG2288 V4.X, RUGGEDCOM RSG2288 V5.X, RUGGEDCOM RSG2288NC V4.X, RUGGEDCOM RSG2288NC V5.X, RUGGEDCOM RSG2300 V4.X, RUGGEDCOM RSG2300 V5.X, RUGGEDCOM RSG2300F, RUGGEDCOM RSG2300NC V4.X, RUGGEDCOM RSG2300NC V5.X, RUGGEDCOM RSG2300P V4.X, RUGGEDCOM RSG2300P V5.X, RUGGEDCOM RSG2300PF, RUGGEDCOM RSG2300PNC V4.X, RUGGEDCOM RSG2300PNC V5.X, RUGGEDCOM RSG2488 V4.X, RUGGEDCOM RSG2488 V5.X, RUGGEDCOM RSG2488F, RUGGEDCOM RSG2488NC V4.X, RUGGEDCOM RSG2488NC V5.X, RUGGEDCOM RSG907R, RUGGEDCOM RSG908C, RUGGEDCOM RSG909R, RUGGEDCOM RSG910C, RUGGEDCOM RSG920P V4.X, RUGGEDCOM RSG920P V5.X, RUGGEDCOM RSG920PNC V4.X, RUGGEDCOM RSG920PNC V5.X, RUGGEDCOM RSL910, RUGGEDCOM RSL910NC, RUGGEDCOM RST2228, RUGGEDCOM RST2228P, RUGGEDCOM RST916C, RUGGEDCOM RST916P. Affected devices are vulnerable to a web-based code injection attack via the console. An attacker could exploit this vulnerability to inject code into the web server and cause malicious behavior in legitimate users accessing certain web resources on the affected device.
SSVC
Exploitation: none Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
  • CWE-94 - Improper Control of Generation of Code ('Code Injection')
Assigner
Impacted products
Vendor Product Version
Siemens RUGGEDCOM i800 Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM i800NC Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM i801 Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM i801NC Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM i802 Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM i802NC Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM i803 Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM i803NC Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM M2100 Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM M2100F Affected: 0 , < * (custom)
Create a notification for this product.
Siemens RUGGEDCOM M2100NC Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM M2200 Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM M2200F Affected: 0 , < * (custom)
Create a notification for this product.
Siemens RUGGEDCOM M2200NC Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM M969 Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM M969F Affected: 0 , < * (custom)
Create a notification for this product.
Siemens RUGGEDCOM M969NC Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RMC30 Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RMC30NC Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RMC8388 V4.X Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RMC8388 V5.X Affected: 0 , < V5.6.0 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RMC8388NC V4.X Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RMC8388NC V5.X Affected: 0 , < V5.6.0 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RP110 Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RP110NC Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS1600 Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS1600F Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS1600FNC Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS1600NC Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS1600T Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS1600TNC Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS400 Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS400F Affected: 0 , < * (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS400NC Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS401 Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS401NC Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS416 Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS416F Affected: 0 , < * (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS416NC Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS416NCv2 V4.X Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS416NCv2 V5.X Affected: 0 , < V5.6.0 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS416P Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS416PF Affected: 0 , < * (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS416PNC Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS416PNCv2 V4.X Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS416PNCv2 V5.X Affected: 0 , < V5.6.0 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS416Pv2 V4.X Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS416Pv2 V5.X Affected: 0 , < V5.6.0 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS416v2 V4.X Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS416v2 V5.X Affected: 0 , < V5.6.0 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS8000 Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS8000A Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS8000ANC Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS8000H Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS8000HNC Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS8000NC Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS8000T Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS8000TNC Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS900 Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS900 (32M) V4.X Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS900 (32M) V5.X Affected: 0 , < V5.6.0 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS900F Affected: 0 , < * (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS900G Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS900G (32M) V4.X Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS900G (32M) V5.X Affected: 0 , < V5.6.0 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS900GF Affected: 0 , < * (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS900GNC Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS900GNC(32M) V4.X Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS900GNC(32M) V5.X Affected: 0 , < V5.6.0 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS900GP Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS900GPF Affected: 0 , < * (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS900GPNC Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS900L Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS900LNC Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS900M-GETS-C01 Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS900M-GETS-XX Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS900M-STND-C01 Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS900M-STND-XX Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS900MNC-GETS-C01 Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS900MNC-GETS-XX Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS900MNC-STND-XX Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS900MNC-STND-XX-C01 Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS900NC Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS900NC(32M) V4.X Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS900NC(32M) V5.X Affected: 0 , < V5.6.0 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS900W Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS910 Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS910L Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS910LNC Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS910NC Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS910W Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS920L Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS920LNC Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS920W Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS930L Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS930LNC Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS930W Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS940G Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS940GF Affected: 0 , < * (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS940GNC Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS969 Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RS969NC Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RSG2100 Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RSG2100 (32M) V4.X Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RSG2100 (32M) V5.X Affected: 0 , < V5.6.0 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RSG2100F Affected: 0 , < * (custom)
Create a notification for this product.
Siemens RUGGEDCOM RSG2100NC Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RSG2100NC(32M) V4.X Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RSG2100NC(32M) V5.X Affected: 0 , < V5.6.0 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RSG2100P Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RSG2100P (32M) V4.X Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RSG2100P (32M) V5.X Affected: 0 , < V5.6.0 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RSG2100PF Affected: 0 , < * (custom)
Create a notification for this product.
Siemens RUGGEDCOM RSG2100PNC Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RSG2100PNC (32M) V4.X Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RSG2100PNC (32M) V5.X Affected: 0 , < V5.6.0 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RSG2200 Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RSG2200F Affected: 0 , < * (custom)
Create a notification for this product.
Siemens RUGGEDCOM RSG2200NC Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RSG2288 V4.X Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RSG2288 V5.X Affected: 0 , < V5.6.0 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RSG2288NC V4.X Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RSG2288NC V5.X Affected: 0 , < V5.6.0 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RSG2300 V4.X Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RSG2300 V5.X Affected: 0 , < V5.6.0 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RSG2300F Affected: 0 , < * (custom)
Create a notification for this product.
Siemens RUGGEDCOM RSG2300NC V4.X Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RSG2300NC V5.X Affected: 0 , < V5.6.0 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RSG2300P V4.X Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RSG2300P V5.X Affected: 0 , < V5.6.0 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RSG2300PF Affected: 0 , < * (custom)
Create a notification for this product.
Siemens RUGGEDCOM RSG2300PNC V4.X Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RSG2300PNC V5.X Affected: 0 , < V5.6.0 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RSG2488 V4.X Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RSG2488 V5.X Affected: 0 , < V5.6.0 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RSG2488F Affected: 0 , < * (custom)
Create a notification for this product.
Siemens RUGGEDCOM RSG2488NC V4.X Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RSG2488NC V5.X Affected: 0 , < V5.6.0 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RSG907R Affected: 0 , < V5.6.0 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RSG908C Affected: 0 , < V5.6.0 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RSG909R Affected: 0 , < V5.6.0 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RSG910C Affected: 0 , < V5.6.0 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RSG920P V4.X Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RSG920P V5.X Affected: 0 , < V5.6.0 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RSG920PNC V4.X Affected: 0 , < V4.3.8 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RSG920PNC V5.X Affected: 0 , < V5.6.0 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RSL910 Affected: 0 , < V5.6.0 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RSL910NC Affected: 0 , < V5.6.0 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RST2228 Affected: 0 , < V5.6.0 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RST2228P Affected: 0 , < V5.6.0 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RST916C Affected: 0 , < V5.6.0 (custom)
Create a notification for this product.
Siemens RUGGEDCOM RST916P Affected: 0 , < V5.6.0 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T09:15:15.757Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-840800.pdf"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-34663",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-18T15:23:03.035745Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-21T13:51:48.068Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM i800",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM i800NC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM i801",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM i801NC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM i802",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM i802NC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM i803",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM i803NC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM M2100",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM M2100F",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM M2100NC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM M2200",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM M2200F",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM M2200NC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM M969",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM M969F",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM M969NC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RMC30",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RMC30NC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RMC8388 V4.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RMC8388 V5.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.6.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RMC8388NC V4.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RMC8388NC V5.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.6.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RP110",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RP110NC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS1600",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS1600F",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS1600FNC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS1600NC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS1600T",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS1600TNC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS400",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS400F",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS400NC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS401",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS401NC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS416",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS416F",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS416NC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS416NCv2 V4.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS416NCv2 V5.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.6.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS416P",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS416PF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS416PNC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS416PNCv2 V4.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS416PNCv2 V5.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.6.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS416Pv2 V4.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS416Pv2 V5.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.6.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS416v2 V4.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS416v2 V5.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.6.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS8000",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS8000A",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS8000ANC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS8000H",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS8000HNC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS8000NC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS8000T",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS8000TNC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS900",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS900 (32M) V4.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS900 (32M) V5.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.6.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS900F",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS900G",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS900G (32M) V4.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS900G (32M) V5.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.6.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS900GF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS900GNC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS900GNC(32M) V4.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS900GNC(32M) V5.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.6.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS900GP",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS900GPF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS900GPNC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS900L",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS900LNC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS900M-GETS-C01",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS900M-GETS-XX",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS900M-STND-C01",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS900M-STND-XX",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS900MNC-GETS-C01",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS900MNC-GETS-XX",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS900MNC-STND-XX",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS900MNC-STND-XX-C01",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS900NC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS900NC(32M) V4.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS900NC(32M) V5.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.6.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS900W",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS910",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS910L",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS910LNC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS910NC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS910W",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS920L",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS920LNC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS920W",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS930L",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS930LNC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS930W",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS940G",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS940GF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS940GNC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS969",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RS969NC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG2100",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG2100 (32M) V4.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG2100 (32M) V5.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.6.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG2100F",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG2100NC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG2100NC(32M) V4.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG2100NC(32M) V5.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.6.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG2100P",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG2100P (32M) V4.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG2100P (32M) V5.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.6.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG2100PF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG2100PNC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG2100PNC (32M) V4.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG2100PNC (32M) V5.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.6.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG2200",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG2200F",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG2200NC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG2288 V4.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG2288 V5.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.6.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG2288NC V4.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG2288NC V5.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.6.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG2300 V4.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG2300 V5.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.6.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG2300F",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG2300NC V4.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG2300NC V5.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.6.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG2300P V4.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG2300P V5.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.6.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG2300PF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG2300PNC V4.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG2300PNC V5.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.6.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG2488 V4.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG2488 V5.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.6.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG2488F",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG2488NC V4.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG2488NC V5.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.6.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG907R",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.6.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG908C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.6.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG909R",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.6.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG910C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.6.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG920P V4.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG920P V5.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.6.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG920PNC V4.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.3.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSG920PNC V5.X",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.6.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSL910",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.6.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RSL910NC",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.6.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RST2228",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.6.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RST2228P",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.6.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RST916C",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.6.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "RUGGEDCOM RST916P",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V5.6.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in RUGGEDCOM i800, RUGGEDCOM i800NC, RUGGEDCOM i801, RUGGEDCOM i801NC, RUGGEDCOM i802, RUGGEDCOM i802NC, RUGGEDCOM i803, RUGGEDCOM i803NC, RUGGEDCOM M2100, RUGGEDCOM M2100F, RUGGEDCOM M2100NC, RUGGEDCOM M2200, RUGGEDCOM M2200F, RUGGEDCOM M2200NC, RUGGEDCOM M969, RUGGEDCOM M969F, RUGGEDCOM M969NC, RUGGEDCOM RMC30, RUGGEDCOM RMC30NC, RUGGEDCOM RMC8388 V4.X, RUGGEDCOM RMC8388 V5.X, RUGGEDCOM RMC8388NC V4.X, RUGGEDCOM RMC8388NC V5.X, RUGGEDCOM RP110, RUGGEDCOM RP110NC, RUGGEDCOM RS1600, RUGGEDCOM RS1600F, RUGGEDCOM RS1600FNC, RUGGEDCOM RS1600NC, RUGGEDCOM RS1600T, RUGGEDCOM RS1600TNC, RUGGEDCOM RS400, RUGGEDCOM RS400F, RUGGEDCOM RS400NC, RUGGEDCOM RS401, RUGGEDCOM RS401NC, RUGGEDCOM RS416, RUGGEDCOM RS416F, RUGGEDCOM RS416NC, RUGGEDCOM RS416NCv2 V4.X, RUGGEDCOM RS416NCv2 V5.X, RUGGEDCOM RS416P, RUGGEDCOM RS416PF, RUGGEDCOM RS416PNC, RUGGEDCOM RS416PNCv2 V4.X, RUGGEDCOM RS416PNCv2 V5.X, RUGGEDCOM RS416Pv2 V4.X, RUGGEDCOM RS416Pv2 V5.X, RUGGEDCOM RS416v2 V4.X, RUGGEDCOM RS416v2 V5.X, RUGGEDCOM RS8000, RUGGEDCOM RS8000A, RUGGEDCOM RS8000ANC, RUGGEDCOM RS8000H, RUGGEDCOM RS8000HNC, RUGGEDCOM RS8000NC, RUGGEDCOM RS8000T, RUGGEDCOM RS8000TNC, RUGGEDCOM RS900, RUGGEDCOM RS900 (32M) V4.X, RUGGEDCOM RS900 (32M) V5.X, RUGGEDCOM RS900F, RUGGEDCOM RS900G, RUGGEDCOM RS900G (32M) V4.X, RUGGEDCOM RS900G (32M) V5.X, RUGGEDCOM RS900GF, RUGGEDCOM RS900GNC, RUGGEDCOM RS900GNC(32M) V4.X, RUGGEDCOM RS900GNC(32M) V5.X, RUGGEDCOM RS900GP, RUGGEDCOM RS900GPF, RUGGEDCOM RS900GPNC, RUGGEDCOM RS900L, RUGGEDCOM RS900LNC, RUGGEDCOM RS900M-GETS-C01, RUGGEDCOM RS900M-GETS-XX, RUGGEDCOM RS900M-STND-C01, RUGGEDCOM RS900M-STND-XX, RUGGEDCOM RS900MNC-GETS-C01, RUGGEDCOM RS900MNC-GETS-XX, RUGGEDCOM RS900MNC-STND-XX, RUGGEDCOM RS900MNC-STND-XX-C01, RUGGEDCOM RS900NC, RUGGEDCOM RS900NC(32M) V4.X, RUGGEDCOM RS900NC(32M) V5.X, RUGGEDCOM RS900W, RUGGEDCOM RS910, RUGGEDCOM RS910L, RUGGEDCOM RS910LNC, RUGGEDCOM RS910NC, RUGGEDCOM RS910W, RUGGEDCOM RS920L, RUGGEDCOM RS920LNC, RUGGEDCOM RS920W, RUGGEDCOM RS930L, RUGGEDCOM RS930LNC, RUGGEDCOM RS930W, RUGGEDCOM RS940G, RUGGEDCOM RS940GF, RUGGEDCOM RS940GNC, RUGGEDCOM RS969, RUGGEDCOM RS969NC, RUGGEDCOM RSG2100, RUGGEDCOM RSG2100 (32M) V4.X, RUGGEDCOM RSG2100 (32M) V5.X, RUGGEDCOM RSG2100F, RUGGEDCOM RSG2100NC, RUGGEDCOM RSG2100NC(32M) V4.X, RUGGEDCOM RSG2100NC(32M) V5.X, RUGGEDCOM RSG2100P, RUGGEDCOM RSG2100P (32M) V4.X, RUGGEDCOM RSG2100P (32M) V5.X, RUGGEDCOM RSG2100PF, RUGGEDCOM RSG2100PNC, RUGGEDCOM RSG2100PNC (32M) V4.X, RUGGEDCOM RSG2100PNC (32M) V5.X, RUGGEDCOM RSG2200, RUGGEDCOM RSG2200F, RUGGEDCOM RSG2200NC, RUGGEDCOM RSG2288 V4.X, RUGGEDCOM RSG2288 V5.X, RUGGEDCOM RSG2288NC V4.X, RUGGEDCOM RSG2288NC V5.X, RUGGEDCOM RSG2300 V4.X, RUGGEDCOM RSG2300 V5.X, RUGGEDCOM RSG2300F, RUGGEDCOM RSG2300NC V4.X, RUGGEDCOM RSG2300NC V5.X, RUGGEDCOM RSG2300P V4.X, RUGGEDCOM RSG2300P V5.X, RUGGEDCOM RSG2300PF, RUGGEDCOM RSG2300PNC V4.X, RUGGEDCOM RSG2300PNC V5.X, RUGGEDCOM RSG2488 V4.X, RUGGEDCOM RSG2488 V5.X, RUGGEDCOM RSG2488F, RUGGEDCOM RSG2488NC V4.X, RUGGEDCOM RSG2488NC V5.X, RUGGEDCOM RSG907R, RUGGEDCOM RSG908C, RUGGEDCOM RSG909R, RUGGEDCOM RSG910C, RUGGEDCOM RSG920P V4.X, RUGGEDCOM RSG920P V5.X, RUGGEDCOM RSG920PNC V4.X, RUGGEDCOM RSG920PNC V5.X, RUGGEDCOM RSL910, RUGGEDCOM RSL910NC, RUGGEDCOM RST2228, RUGGEDCOM RST2228P, RUGGEDCOM RST916C, RUGGEDCOM RST916P. Affected devices are vulnerable to a web-based code injection attack via the console.\r\n\r\nAn attacker could exploit this vulnerability to inject code into the web server and cause malicious behavior in legitimate users accessing certain web resources on the affected\r\ndevice."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 8,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-94",
              "description": "CWE-94: Improper Control of Generation of Code (\u0027Code Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-08-12T11:11:14.837Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-840800.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-840800.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-34663",
    "datePublished": "2022-07-12T10:07:25.000Z",
    "dateReserved": "2022-06-27T00:00:00.000Z",
    "dateUpdated": "2025-08-12T11:11:14.837Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-34456 (GCVE-0-2022-34456)

Vulnerability from cvelistv5 – Published: 2023-01-18 05:11 – Updated: 2025-04-03 19:33
VLAI
Summary
Dell EMC Metro node, Version(s) prior to 7.1, contain a Code Injection Vulnerability. An authenticated nonprivileged attacker could potentially exploit this vulnerability, leading to the execution of arbitrary OS commands on the application.
SSVC
Exploitation: none Automatable: no Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
  • CWE-94 - Improper Control of Generation of Code ('Code Injection')
Assigner
References
Impacted products
Vendor Product Version
Dell EMC Metro node Affected: 0 , < 7.1 (custom)
Create a notification for this product.
Date Public
2022-10-07 16:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T09:15:15.240Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/kbdoc/en-us/000204057/dsa-2022-267-dell-emc-metronode-vs5-security-update-for-multiple-third-party-component-vulnerabilities"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-34456",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-02T16:24:27.350882Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-03T19:33:34.207Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Metro node",
          "vendor": "Dell EMC",
          "versions": [
            {
              "lessThan": "7.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2022-10-07T16:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cdiv\u003e\u003cdiv\u003eDell EMC Metro node, Version(s) prior to 7.1, contain a Code Injection Vulnerability. An authenticated nonprivileged attacker could potentially exploit this vulnerability, leading to the execution of arbitrary OS commands on the application.\u003c/div\u003e\u003c/div\u003e\n\n"
            }
          ],
          "value": "\nDell EMC Metro node, Version(s) prior to 7.1, contain a Code Injection Vulnerability. An authenticated nonprivileged attacker could potentially exploit this vulnerability, leading to the execution of arbitrary OS commands on the application.\n\n\n\n\n\n"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-94",
              "description": "CWE-94: Improper Control of Generation of Code (\u0027Code Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-01-18T05:11:42.211Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000204057/dsa-2022-267-dell-emc-metronode-vs5-security-update-for-multiple-third-party-component-vulnerabilities"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2022-34456",
    "datePublished": "2023-01-18T05:11:42.211Z",
    "dateReserved": "2022-06-23T18:55:17.135Z",
    "dateUpdated": "2025-04-03T19:33:34.207Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-33725 (GCVE-0-2022-33725)

Vulnerability from cvelistv5 – Published: 2022-08-05 15:15 – Updated: 2024-08-03 08:09
VLAI
Summary
A vulnerability using PendingIntent in Knox VPN prior to SMR Aug-2022 Release 1 allows attackers to access content providers with system privilege.
CWE
  • CWE-94 - Improper Control of Generation of Code
Assigner
References
Impacted products
Vendor Product Version
Samsung Mobile Samsung Mobile Devices Affected: Q(10), R(11) , < SMR Aug-2022 Release 1 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T08:09:22.643Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://security.samsungmobile.com/securityUpdate.smsb?year=2022\u0026month=08"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Samsung Mobile Devices",
          "vendor": "Samsung Mobile",
          "versions": [
            {
              "lessThan": "SMR Aug-2022 Release 1",
              "status": "affected",
              "version": "Q(10), R(11)",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability using PendingIntent in Knox VPN prior to SMR Aug-2022 Release 1 allows attackers to access content providers with system privilege."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 4,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-94",
              "description": "CWE-94: Improper Control of Generation of Code",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-08-05T15:15:23.000Z",
        "orgId": "3af57064-a867-422c-b2ad-40307b65c458",
        "shortName": "Samsung Mobile"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://security.samsungmobile.com/securityUpdate.smsb?year=2022\u0026month=08"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "mobile.security@samsung.com",
          "ID": "CVE-2022-33725",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Samsung Mobile Devices",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "Q(10), R(11)",
                            "version_value": "SMR Aug-2022 Release 1"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Samsung Mobile"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability using PendingIntent in Knox VPN prior to SMR Aug-2022 Release 1 allows attackers to access content providers with system privilege."
            }
          ]
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 4,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-94: Improper Control of Generation of Code"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://security.samsungmobile.com/securityUpdate.smsb?year=2022\u0026month=08",
              "refsource": "MISC",
              "url": "https://security.samsungmobile.com/securityUpdate.smsb?year=2022\u0026month=08"
            }
          ]
        },
        "source": {
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "3af57064-a867-422c-b2ad-40307b65c458",
    "assignerShortName": "Samsung Mobile",
    "cveId": "CVE-2022-33725",
    "datePublished": "2022-08-05T15:15:23.000Z",
    "dateReserved": "2022-06-15T00:00:00.000Z",
    "dateUpdated": "2024-08-03T08:09:22.643Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-33721 (GCVE-0-2022-33721)

Vulnerability from cvelistv5 – Published: 2022-08-05 15:19 – Updated: 2024-08-03 08:09
VLAI
Summary
A vulnerability using PendingIntent in DeX for PC prior to SMR Aug-2022 Release 1 allows attackers to access files with system privilege.
CWE
  • CWE-94 - Improper Control of Generation of Code (&#39;Code Injection&#39;)
Assigner
References
Impacted products
Vendor Product Version
Samsung Mobile Samsung Mobile Devices Affected: S(12) , < SMR Aug-2022 Release 1 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T08:09:22.599Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://security.samsungmobile.com/securityUpdate.smsb?year=2022\u0026month=08"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Samsung Mobile Devices",
          "vendor": "Samsung Mobile",
          "versions": [
            {
              "lessThan": "SMR Aug-2022 Release 1",
              "status": "affected",
              "version": "S(12)",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability using PendingIntent in DeX for PC prior to SMR Aug-2022 Release 1 allows attackers to access files with system privilege."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 4.4,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-94",
              "description": "CWE-94: Improper Control of Generation of Code (\u0026#39;Code Injection\u0026#39;)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-08-05T15:19:22.000Z",
        "orgId": "3af57064-a867-422c-b2ad-40307b65c458",
        "shortName": "Samsung Mobile"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://security.samsungmobile.com/securityUpdate.smsb?year=2022\u0026month=08"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "mobile.security@samsung.com",
          "ID": "CVE-2022-33721",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Samsung Mobile Devices",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "S(12)",
                            "version_value": "SMR Aug-2022 Release 1"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Samsung Mobile"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability using PendingIntent in DeX for PC prior to SMR Aug-2022 Release 1 allows attackers to access files with system privilege."
            }
          ]
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 4.4,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-94: Improper Control of Generation of Code (\u0026#39;Code Injection\u0026#39;)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://security.samsungmobile.com/securityUpdate.smsb?year=2022\u0026month=08",
              "refsource": "MISC",
              "url": "https://security.samsungmobile.com/securityUpdate.smsb?year=2022\u0026month=08"
            }
          ]
        },
        "source": {
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "3af57064-a867-422c-b2ad-40307b65c458",
    "assignerShortName": "Samsung Mobile",
    "cveId": "CVE-2022-33721",
    "datePublished": "2022-08-05T15:19:22.000Z",
    "dateReserved": "2022-06-15T00:00:00.000Z",
    "dateUpdated": "2024-08-03T08:09:22.599Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-31161 (GCVE-0-2022-31161)

Vulnerability from cvelistv5 – Published: 2022-07-15 00:00 – Updated: 2025-04-23 18:01
VLAI
Title
Roxy-WI Vulnerable to Unauthenticated Remote Code Execution via ssl_cert Upload
Summary
Roxy-WI is a Web interface for managing HAProxy, Nginx and Keepalived servers. Prior to version 6.1.1.0, the system command can be run remotely via the subprocess_execute function without processing the inputs received from the user in the /app/options.py file. Version 6.1.1.0 contains a patch for this issue.
SSVC
Exploitation: none Automatable: yes Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
  • CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
  • CWE-94 - Improper Control of Generation of Code ('Code Injection')
Assigner
Impacted products
Vendor Product Version
hap-wi roxy-wi Affected: < 6.1.1.0
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T07:11:39.671Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://github.com/hap-wi/roxy-wi/security/advisories/GHSA-pg3w-8p63-x483"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://github.com/hap-wi/roxy-wi/releases/tag/v6.1.1.0"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "http://packetstormsecurity.com/files/171652/Roxy-WI-6.1.1.0-Remote-Code-Execution.html"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-31161",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-23T15:48:54.450162Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-23T18:01:57.263Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "roxy-wi",
          "vendor": "hap-wi",
          "versions": [
            {
              "status": "affected",
              "version": "\u003c 6.1.1.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Roxy-WI is a Web interface for managing HAProxy, Nginx and Keepalived servers. Prior to version 6.1.1.0, the system command can be run remotely via the subprocess_execute function without processing the inputs received from the user in the /app/options.py file. Version 6.1.1.0 contains a patch for this issue."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 10,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:L",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-77",
              "description": "CWE-77: Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-94",
              "description": "CWE-94: Improper Control of Generation of Code (\u0027Code Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-04-03T00:00:00.000Z",
        "orgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
        "shortName": "GitHub_M"
      },
      "references": [
        {
          "url": "https://github.com/hap-wi/roxy-wi/security/advisories/GHSA-pg3w-8p63-x483"
        },
        {
          "url": "https://github.com/hap-wi/roxy-wi/releases/tag/v6.1.1.0"
        },
        {
          "url": "http://packetstormsecurity.com/files/171652/Roxy-WI-6.1.1.0-Remote-Code-Execution.html"
        }
      ],
      "source": {
        "advisory": "GHSA-pg3w-8p63-x483",
        "discovery": "UNKNOWN"
      },
      "title": "Roxy-WI Vulnerable to Unauthenticated Remote Code Execution via ssl_cert Upload"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
    "assignerShortName": "GitHub_M",
    "cveId": "CVE-2022-31161",
    "datePublished": "2022-07-15T00:00:00.000Z",
    "dateReserved": "2022-05-18T00:00:00.000Z",
    "dateUpdated": "2025-04-23T18:01:57.263Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-29821 (GCVE-0-2022-29821)

Vulnerability from cvelistv5 – Published: 2022-04-28 09:55 – Updated: 2024-08-03 06:33
VLAI
Summary
In JetBrains Rider before 2022.1 local code execution via links in ReSharper Quick Documentation was possible
CWE
  • CWE-94 - Improper Control of Generation of Code ('Code Injection')
Assigner
References
Impacted products
Vendor Product Version
JetBrains Rider Affected: 2022.1 , < 2022.1 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T06:33:42.841Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.jetbrains.com/privacy-security/issues-fixed/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Rider",
          "vendor": "JetBrains",
          "versions": [
            {
              "lessThan": "2022.1",
              "status": "affected",
              "version": "2022.1",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "In JetBrains Rider before 2022.1 local code execution via links in ReSharper Quick Documentation was possible"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 6.9,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:R/S:C/C:H/I:H/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-94",
              "description": "CWE-94: Improper Control of Generation of Code (\u0027Code Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-04-28T09:55:31.000Z",
        "orgId": "547ada31-17d8-4964-bc5f-1b8238ba8014",
        "shortName": "JetBrains"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.jetbrains.com/privacy-security/issues-fixed/"
        }
      ],
      "source": {
        "defect": [
          "RIDER-74099"
        ],
        "discovery": "EXTERNAL"
      },
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "security@jetbrains.com",
          "ID": "CVE-2022-29821",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Rider",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "2022.1",
                            "version_value": "2022.1"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "JetBrains"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "In JetBrains Rider before 2022.1 local code execution via links in ReSharper Quick Documentation was possible"
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "HIGH",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 6.9,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:R/S:C/C:H/I:H/A:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-94: Improper Control of Generation of Code (\u0027Code Injection\u0027)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.jetbrains.com/privacy-security/issues-fixed/",
              "refsource": "MISC",
              "url": "https://www.jetbrains.com/privacy-security/issues-fixed/"
            }
          ]
        },
        "source": {
          "defect": [
            "RIDER-74099"
          ],
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "547ada31-17d8-4964-bc5f-1b8238ba8014",
    "assignerShortName": "JetBrains",
    "cveId": "CVE-2022-29821",
    "datePublished": "2022-04-28T09:55:31.000Z",
    "dateReserved": "2022-04-27T00:00:00.000Z",
    "dateUpdated": "2024-08-03T06:33:42.841Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-29819 (GCVE-0-2022-29819)

Vulnerability from cvelistv5 – Published: 2022-04-28 09:55 – Updated: 2024-08-03 06:33
VLAI
Summary
In JetBrains IntelliJ IDEA before 2022.1 local code execution via links in Quick Documentation was possible
CWE
  • CWE-94 - Improper Control of Generation of Code ('Code Injection')
Assigner
References
Impacted products
Vendor Product Version
JetBrains IntelliJ IDEA Affected: 2022.1 , < 2022.1 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T06:33:42.822Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.jetbrains.com/privacy-security/issues-fixed/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "IntelliJ IDEA",
          "vendor": "JetBrains",
          "versions": [
            {
              "lessThan": "2022.1",
              "status": "affected",
              "version": "2022.1",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "In JetBrains IntelliJ IDEA before 2022.1 local code execution via links in Quick Documentation was possible"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 6.9,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:R/S:C/C:H/I:H/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-94",
              "description": "CWE-94: Improper Control of Generation of Code (\u0027Code Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-04-28T09:55:28.000Z",
        "orgId": "547ada31-17d8-4964-bc5f-1b8238ba8014",
        "shortName": "JetBrains"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.jetbrains.com/privacy-security/issues-fixed/"
        }
      ],
      "source": {
        "defect": [
          "IDEA-289398"
        ],
        "discovery": "EXTERNAL"
      },
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "security@jetbrains.com",
          "ID": "CVE-2022-29819",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "IntelliJ IDEA",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "2022.1",
                            "version_value": "2022.1"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "JetBrains"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "In JetBrains IntelliJ IDEA before 2022.1 local code execution via links in Quick Documentation was possible"
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "HIGH",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 6.9,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:R/S:C/C:H/I:H/A:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-94: Improper Control of Generation of Code (\u0027Code Injection\u0027)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.jetbrains.com/privacy-security/issues-fixed/",
              "refsource": "MISC",
              "url": "https://www.jetbrains.com/privacy-security/issues-fixed/"
            }
          ]
        },
        "source": {
          "defect": [
            "IDEA-289398"
          ],
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "547ada31-17d8-4964-bc5f-1b8238ba8014",
    "assignerShortName": "JetBrains",
    "cveId": "CVE-2022-29819",
    "datePublished": "2022-04-28T09:55:28.000Z",
    "dateReserved": "2022-04-27T00:00:00.000Z",
    "dateUpdated": "2024-08-03T06:33:42.822Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-29815 (GCVE-0-2022-29815)

Vulnerability from cvelistv5 – Published: 2022-04-28 09:55 – Updated: 2024-08-03 06:33
VLAI
Summary
In JetBrains IntelliJ IDEA before 2022.1 local code execution via workspace settings was possible
CWE
  • CWE-94 - Improper Control of Generation of Code ('Code Injection')
Assigner
References
Impacted products
Vendor Product Version
JetBrains IntelliJ IDEA Affected: 2022.1 , < 2022.1 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T06:33:42.657Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.jetbrains.com/privacy-security/issues-fixed/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "IntelliJ IDEA",
          "vendor": "JetBrains",
          "versions": [
            {
              "lessThan": "2022.1",
              "status": "affected",
              "version": "2022.1",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "In JetBrains IntelliJ IDEA before 2022.1 local code execution via workspace settings was possible"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 6.9,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:R/S:C/C:H/I:H/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-94",
              "description": "CWE-94: Improper Control of Generation of Code (\u0027Code Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-04-28T09:55:23.000Z",
        "orgId": "547ada31-17d8-4964-bc5f-1b8238ba8014",
        "shortName": "JetBrains"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.jetbrains.com/privacy-security/issues-fixed/"
        }
      ],
      "source": {
        "defect": [
          "IDEA-283824",
          "IDEA-283968"
        ],
        "discovery": "EXTERNAL"
      },
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "security@jetbrains.com",
          "ID": "CVE-2022-29815",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "IntelliJ IDEA",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "2022.1",
                            "version_value": "2022.1"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "JetBrains"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "In JetBrains IntelliJ IDEA before 2022.1 local code execution via workspace settings was possible"
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "HIGH",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 6.9,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:R/S:C/C:H/I:H/A:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-94: Improper Control of Generation of Code (\u0027Code Injection\u0027)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.jetbrains.com/privacy-security/issues-fixed/",
              "refsource": "MISC",
              "url": "https://www.jetbrains.com/privacy-security/issues-fixed/"
            }
          ]
        },
        "source": {
          "defect": [
            "IDEA-283824",
            "IDEA-283968"
          ],
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "547ada31-17d8-4964-bc5f-1b8238ba8014",
    "assignerShortName": "JetBrains",
    "cveId": "CVE-2022-29815",
    "datePublished": "2022-04-28T09:55:23.000Z",
    "dateReserved": "2022-04-27T00:00:00.000Z",
    "dateUpdated": "2024-08-03T06:33:42.657Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-29814 (GCVE-0-2022-29814)

Vulnerability from cvelistv5 – Published: 2022-04-28 09:55 – Updated: 2024-08-03 06:33
VLAI
Summary
In JetBrains IntelliJ IDEA before 2022.1 local code execution via HTML descriptions in custom JSON schemas was possible
CWE
  • CWE-94 - Improper Control of Generation of Code ('Code Injection')
Assigner
References
Impacted products
Vendor Product Version
JetBrains IntelliJ IDEA Affected: 2022.1 , < 2022.1 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T06:33:42.902Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.jetbrains.com/privacy-security/issues-fixed/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "IntelliJ IDEA",
          "vendor": "JetBrains",
          "versions": [
            {
              "lessThan": "2022.1",
              "status": "affected",
              "version": "2022.1",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "In JetBrains IntelliJ IDEA before 2022.1 local code execution via HTML descriptions in custom JSON schemas was possible"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 6.9,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:R/S:C/C:H/I:H/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-94",
              "description": "CWE-94: Improper Control of Generation of Code (\u0027Code Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-04-28T09:55:21.000Z",
        "orgId": "547ada31-17d8-4964-bc5f-1b8238ba8014",
        "shortName": "JetBrains"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.jetbrains.com/privacy-security/issues-fixed/"
        }
      ],
      "source": {
        "defect": [
          "IDEA-283967"
        ],
        "discovery": "EXTERNAL"
      },
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "security@jetbrains.com",
          "ID": "CVE-2022-29814",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "IntelliJ IDEA",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "2022.1",
                            "version_value": "2022.1"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "JetBrains"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "In JetBrains IntelliJ IDEA before 2022.1 local code execution via HTML descriptions in custom JSON schemas was possible"
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "HIGH",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 6.9,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:R/S:C/C:H/I:H/A:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-94: Improper Control of Generation of Code (\u0027Code Injection\u0027)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.jetbrains.com/privacy-security/issues-fixed/",
              "refsource": "MISC",
              "url": "https://www.jetbrains.com/privacy-security/issues-fixed/"
            }
          ]
        },
        "source": {
          "defect": [
            "IDEA-283967"
          ],
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "547ada31-17d8-4964-bc5f-1b8238ba8014",
    "assignerShortName": "JetBrains",
    "cveId": "CVE-2022-29814",
    "datePublished": "2022-04-28T09:55:21.000Z",
    "dateReserved": "2022-04-27T00:00:00.000Z",
    "dateUpdated": "2024-08-03T06:33:42.902Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-29813 (GCVE-0-2022-29813)

Vulnerability from cvelistv5 – Published: 2022-04-28 09:55 – Updated: 2024-08-03 06:33
VLAI
Summary
In JetBrains IntelliJ IDEA before 2022.1 local code execution via custom Pandoc path was possible
CWE
  • CWE-94 - Improper Control of Generation of Code ('Code Injection')
Assigner
References
Impacted products
Vendor Product Version
JetBrains IntelliJ IDEA Affected: 2022.1 , < 2022.1 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T06:33:42.799Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.jetbrains.com/privacy-security/issues-fixed/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "IntelliJ IDEA",
          "vendor": "JetBrains",
          "versions": [
            {
              "lessThan": "2022.1",
              "status": "affected",
              "version": "2022.1",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "In JetBrains IntelliJ IDEA before 2022.1 local code execution via custom Pandoc path was possible"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 6.9,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:R/S:C/C:H/I:H/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-94",
              "description": "CWE-94: Improper Control of Generation of Code (\u0027Code Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-04-28T09:55:20.000Z",
        "orgId": "547ada31-17d8-4964-bc5f-1b8238ba8014",
        "shortName": "JetBrains"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.jetbrains.com/privacy-security/issues-fixed/"
        }
      ],
      "source": {
        "defect": [
          "IDEA-288269"
        ],
        "discovery": "EXTERNAL"
      },
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "security@jetbrains.com",
          "ID": "CVE-2022-29813",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "IntelliJ IDEA",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "2022.1",
                            "version_value": "2022.1"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "JetBrains"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "In JetBrains IntelliJ IDEA before 2022.1 local code execution via custom Pandoc path was possible"
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "HIGH",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 6.9,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:R/S:C/C:H/I:H/A:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-94: Improper Control of Generation of Code (\u0027Code Injection\u0027)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.jetbrains.com/privacy-security/issues-fixed/",
              "refsource": "MISC",
              "url": "https://www.jetbrains.com/privacy-security/issues-fixed/"
            }
          ]
        },
        "source": {
          "defect": [
            "IDEA-288269"
          ],
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "547ada31-17d8-4964-bc5f-1b8238ba8014",
    "assignerShortName": "JetBrains",
    "cveId": "CVE-2022-29813",
    "datePublished": "2022-04-28T09:55:20.000Z",
    "dateReserved": "2022-04-27T00:00:00.000Z",
    "dateUpdated": "2024-08-03T06:33:42.799Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

Mitigation
Architecture and Design

Strategy: Refactoring

Refactor your program so that you do not have to dynamically generate code.

Mitigation
Architecture and Design
  • Run your code in a "jail" or similar sandbox environment that enforces strict boundaries between the process and the operating system. This may effectively restrict which code can be executed by your product.
  • Examples include the Unix chroot jail and AppArmor. In general, managed code may provide some protection.
  • This may not be a feasible solution, and it only limits the impact to the operating system; the rest of your application may still be subject to compromise.
  • Be careful to avoid CWE-243 and other weaknesses related to jails.
Mitigation MIT-5
Implementation

Strategy: Input Validation

  • Assume all input is malicious. Use an "accept known good" input validation strategy, i.e., use a list of acceptable inputs that strictly conform to specifications. Reject any input that does not strictly conform to specifications, or transform it into something that does.
  • When performing input validation, consider all potentially relevant properties, including length, type of input, the full range of acceptable values, missing or extra inputs, syntax, consistency across related fields, and conformance to business rules. As an example of business rule logic, "boat" may be syntactically valid because it only contains alphanumeric characters, but it is not valid if the input is only expected to contain colors such as "red" or "blue."
  • Do not rely exclusively on looking for malicious or malformed inputs. This is likely to miss at least one undesirable input, especially if the code's environment changes. This can give attackers enough room to bypass the intended validation. However, denylists can be useful for detecting potential attacks or determining which inputs are so malformed that they should be rejected outright.
  • To reduce the likelihood of code injection, use stringent allowlists that limit which constructs are allowed. If you are dynamically constructing code that invokes a function, then verifying that the input is alphanumeric might be insufficient. An attacker might still be able to reference a dangerous function that you did not intend to allow, such as system(), exec(), or exit().
Mitigation
Testing

Use dynamic tools and techniques that interact with the product using large test suites with many diverse inputs, such as fuzz testing (fuzzing), robustness testing, and fault injection. The product's operation may slow down, but it should not become unstable, crash, or generate incorrect results.

Mitigation MIT-32
Operation

Strategy: Compilation or Build Hardening

Run the code in an environment that performs automatic taint propagation and prevents any command execution that uses tainted variables, such as Perl's "-T" switch. This will force the program to perform validation steps that remove the taint, although you must be careful to correctly validate your inputs so that you do not accidentally mark dangerous inputs as untainted (see CWE-183 and CWE-184).

Mitigation MIT-32
Operation

Strategy: Environment Hardening

Run the code in an environment that performs automatic taint propagation and prevents any command execution that uses tainted variables, such as Perl's "-T" switch. This will force the program to perform validation steps that remove the taint, although you must be careful to correctly validate your inputs so that you do not accidentally mark dangerous inputs as untainted (see CWE-183 and CWE-184).

Mitigation
Implementation

For Python programs, it is frequently encouraged to use the ast.literal_eval() function instead of eval, since it is intentionally designed to avoid executing code. However, an adversary could still cause excessive memory or stack consumption via deeply nested structures [REF-1372], so the python documentation discourages use of ast.literal_eval() on untrusted data [REF-1373].

CAPEC-242: Code Injection

An adversary exploits a weakness in input validation on the target to inject new code into that which is currently executing. This differs from code inclusion in that code inclusion involves the addition or replacement of a reference to a code file, which is subsequently loaded by the target and used as part of the code of some application.

CAPEC-35: Leverage Executable Code in Non-Executable Files

An attack of this type exploits a system's trust in configuration and resource files. When the executable loads the resource (such as an image file or configuration file) the attacker has modified the file to either execute malicious code directly or manipulate the target process (e.g. application server) to execute based on the malicious configuration parameters. Since systems are increasingly interrelated mashing up resources from local and remote sources the possibility of this attack occurring is high.

CAPEC-77: Manipulating User-Controlled Variables

This attack targets user controlled variables (DEBUG=1, PHP Globals, and So Forth). An adversary can override variables leveraging user-supplied, untrusted query variables directly used on the application server without any data sanitization. In extreme cases, the adversary can change variables controlling the business logic of the application. For instance, in languages like PHP, a number of poorly set default configurations may allow the user to override variables.