Common Weakness Enumeration

CWE-15

Allowed

External Control of System or Configuration Setting

Abstraction: Base · Status: Incomplete

One or more system settings or configuration elements can be externally controlled by a user.

145 vulnerabilities reference this CWE, most recent first.

CVE-2025-27889 (GCVE-0-2025-27889)

Vulnerability from cvelistv5 – Published: 2025-07-10 00:00 – Updated: 2025-07-10 18:04
VLAI
Summary
Wing FTP Server before 7.4.4 does not properly validate and sanitize the url parameter of the downloadpass.html endpoint, allowing injection of an arbitrary link. If a user clicks a crafted link, this discloses a cleartext password to the attacker.
SSVC
Exploitation: poc Automatable: no Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-07-10 18:04 UTC
CWE
  • CWE-15 - External Control of System or Configuration Setting
Impacted products
Vendor Product Version
wftpserver Wing FTP Server Affected: 0 , < 7.4.4 (custom)
    cpe:2.3:a:wftpserver:wing_ftp_server:*:*:*:*:*:*:*:*
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-27889",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-07-10T18:04:42.838632Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-07-10T18:04:56.735Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "references": [
          {
            "tags": [
              "exploit"
            ],
            "url": "https://www.rcesecurity.com/2025/06/what-the-null-wing-ftp-server-rce-cve-2025-47812/"
          }
        ],
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Wing FTP Server",
          "vendor": "wftpserver",
          "versions": [
            {
              "lessThan": "7.4.4",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "cpeApplicability": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:wftpserver:wing_ftp_server:*:*:*:*:*:*:*:*",
                  "versionEndExcluding": "7.4.4",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Wing FTP Server before 7.4.4 does not properly validate and sanitize the url parameter of the downloadpass.html endpoint, allowing injection of an arbitrary link. If a user clicks a crafted link, this discloses a cleartext password to the attacker."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 3.4,
            "baseSeverity": "LOW",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:L/I:N/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-15",
              "description": "CWE-15 External Control of System or Configuration Setting",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-07-10T16:55:16.846Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://www.wftpserver.com/wftpserver.htm"
        },
        {
          "url": "https://www.rcesecurity.com/2025/06/what-the-null-wing-ftp-server-rce-cve-2025-47812/"
        },
        {
          "url": "https://github.com/MrTuxracer/advisories/blob/master/CVEs/CVE-2025-27889.txt"
        }
      ],
      "x_generator": {
        "engine": "enrichogram 0.0.1"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2025-27889",
    "datePublished": "2025-07-10T00:00:00.000Z",
    "dateReserved": "2025-03-10T00:00:00.000Z",
    "dateUpdated": "2025-07-10T18:04:56.735Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-27253 (GCVE-0-2025-27253)

Vulnerability from cvelistv5 – Published: 2025-03-10 09:04 – Updated: 2025-10-07 14:16
VLAI
Summary
A CWE-15 "External Control of System or Configuration Setting" in GE Vernova UR IED family devices from version 7.0 up to 8.60 allows an attacker to provide input that establishes a TCP connection through a port forwarding. The lack of the IP address and port validation may allow the attacker to bypass firewall rules or to send malicious traffic in the network.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-03-10 15:33 UTC
CWE
  • CWE-15 - External Control of System or Configuration Setting
Impacted products
Vendor Product Version
GE Vernova N60 multilin Affected: 7.0 , ≤ 8.60 (custom)
Create a notification for this product.
GE Vernova B30 Multilin Affected: 7.0 , ≤ 8.60 (custom)
Create a notification for this product.
GE Vernova B90 Multilin Affected: 7.0 , ≤ 8.60 (custom)
Create a notification for this product.
GE Vernova C30 Multilin Affected: 7.0 , ≤ 8.60 (custom)
Create a notification for this product.
GE Vernova C60 Multilin Affected: 7.0 , ≤ 8.60 (custom)
Create a notification for this product.
GE Vernova C70 Multilin Affected: 7.0 , ≤ 8.60 (custom)
Create a notification for this product.
GE Vernova C95 Multilin Affected: 7.0 , ≤ 8.60 (custom)
Create a notification for this product.
GE Vernova D30 Multilin Affected: 7.0 , ≤ 8.60 (custom)
Create a notification for this product.
GE Vernova D60 Multilin Affected: 7.0 , ≤ 8.60 (custom)
Create a notification for this product.
GE Vernova F35 Multilin Affected: 7.0 , ≤ 8.60 (custom)
Create a notification for this product.
GE Vernova F60 Multilin Affected: 7.0 , ≤ 8.60 (custom)
Create a notification for this product.
GE Vernova G30 Multilin Affected: 7.0 , ≤ 8.60 (custom)
Create a notification for this product.
GE Vernova G60 Multilin Affected: 7.0 , ≤ 8.60 (custom)
Create a notification for this product.
GE Vernova L30 Multilin Affected: 7.0 , ≤ 8.60 (custom)
Create a notification for this product.
GE Vernova L60 Multilin Affected: 7.0 , ≤ 8.60 (custom)
Create a notification for this product.
GE Vernova L90 Multilin Affected: 7.0 , ≤ 8.60 (custom)
Create a notification for this product.
GE Vernova M60 Multilin Affected: 7.0 , ≤ 8.60 (custom)
Create a notification for this product.
GE Vernova T35 Multilin Affected: 7.0 , ≤ 8.60 (custom)
Create a notification for this product.
GE Vernova T60 Multilin Affected: 7.0 , ≤ 8.60 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-27253",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-03-10T15:33:39.489617Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-03-10T15:33:49.185Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "N60 multilin",
          "vendor": "GE Vernova",
          "versions": [
            {
              "lessThanOrEqual": "8.60",
              "status": "affected",
              "version": "7.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "B30 Multilin",
          "vendor": "GE Vernova",
          "versions": [
            {
              "lessThanOrEqual": "8.60",
              "status": "affected",
              "version": "7.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "B90 Multilin",
          "vendor": "GE Vernova",
          "versions": [
            {
              "lessThanOrEqual": "8.60",
              "status": "affected",
              "version": "7.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "C30 Multilin",
          "vendor": "GE Vernova",
          "versions": [
            {
              "lessThanOrEqual": "8.60",
              "status": "affected",
              "version": "7.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "C60 Multilin",
          "vendor": "GE Vernova",
          "versions": [
            {
              "lessThanOrEqual": "8.60",
              "status": "affected",
              "version": "7.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "C70 Multilin",
          "vendor": "GE Vernova",
          "versions": [
            {
              "lessThanOrEqual": "8.60",
              "status": "affected",
              "version": "7.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "C95 Multilin",
          "vendor": "GE Vernova",
          "versions": [
            {
              "lessThanOrEqual": "8.60",
              "status": "affected",
              "version": "7.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "D30 Multilin",
          "vendor": "GE Vernova",
          "versions": [
            {
              "lessThanOrEqual": "8.60",
              "status": "affected",
              "version": "7.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "D60 Multilin",
          "vendor": "GE Vernova",
          "versions": [
            {
              "lessThanOrEqual": "8.60",
              "status": "affected",
              "version": "7.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "F35 Multilin",
          "vendor": "GE Vernova",
          "versions": [
            {
              "lessThanOrEqual": "8.60",
              "status": "affected",
              "version": "7.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "F60 Multilin",
          "vendor": "GE Vernova",
          "versions": [
            {
              "lessThanOrEqual": "8.60",
              "status": "affected",
              "version": "7.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "G30 Multilin",
          "vendor": "GE Vernova",
          "versions": [
            {
              "lessThanOrEqual": "8.60",
              "status": "affected",
              "version": "7.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "G60 Multilin",
          "vendor": "GE Vernova",
          "versions": [
            {
              "lessThanOrEqual": "8.60",
              "status": "affected",
              "version": "7.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "L30 Multilin",
          "vendor": "GE Vernova",
          "versions": [
            {
              "lessThanOrEqual": "8.60",
              "status": "affected",
              "version": "7.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "L60 Multilin",
          "vendor": "GE Vernova",
          "versions": [
            {
              "lessThanOrEqual": "8.60",
              "status": "affected",
              "version": "7.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "L90 Multilin",
          "vendor": "GE Vernova",
          "versions": [
            {
              "lessThanOrEqual": "8.60",
              "status": "affected",
              "version": "7.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "M60 Multilin",
          "vendor": "GE Vernova",
          "versions": [
            {
              "lessThanOrEqual": "8.60",
              "status": "affected",
              "version": "7.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "T35 Multilin",
          "vendor": "GE Vernova",
          "versions": [
            {
              "lessThanOrEqual": "8.60",
              "status": "affected",
              "version": "7.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "T60 Multilin",
          "vendor": "GE Vernova",
          "versions": [
            {
              "lessThanOrEqual": "8.60",
              "status": "affected",
              "version": "7.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "M60 Multilin",
          "vendor": "GE Vernova",
          "versions": [
            {
              "lessThanOrEqual": "8.60",
              "status": "affected",
              "version": "7.0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "A\u0026nbsp;CWE-15 \"External Control of System or Configuration Setting\"\u0026nbsp;in GE Vernova UR IED family devices from version 7.0 up to 8.60 allows an attacker to provide input that establishes a TCP connection through a port forwarding. The lack of the IP address and port validation may allow the attacker to bypass firewall rules or to send malicious traffic in the network."
            }
          ],
          "value": "A\u00a0CWE-15 \"External Control of System or Configuration Setting\"\u00a0in GE Vernova UR IED family devices from version 7.0 up to 8.60 allows an attacker to provide input that establishes a TCP connection through a port forwarding. The lack of the IP address and port validation may allow the attacker to bypass firewall rules or to send malicious traffic in the network."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-1",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-1 Accessing Functionality Not Properly Constrained by ACLs"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 6.1,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:L/I:N/A:L",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-15",
              "description": "CWE-15 External Control of System or Configuration Setting",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-10-07T14:16:49.710Z",
        "orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
        "shortName": "Nozomi"
      },
      "references": [
        {
          "url": "https://www.gevernova.com/grid-solutions/app/DownloadFile.aspx?prod=urfamily\u0026type=21\u0026file=76"
        },
        {
          "url": "https://www.nozominetworks.com/labs/vulnerability-advisories-cve-2025-27253"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
    "assignerShortName": "Nozomi",
    "cveId": "CVE-2025-27253",
    "datePublished": "2025-03-10T09:04:34.413Z",
    "dateReserved": "2025-02-21T08:32:26.973Z",
    "dateUpdated": "2025-10-07T14:16:49.710Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-13091 (GCVE-0-2025-13091)

Vulnerability from cvelistv5 – Published: 2026-02-19 04:36 – Updated: 2026-04-08 17:05
VLAI
Title
Shopire <= 1.0.57 - Missing Authorization to Authenticated (Subscriber+) Limited Plugin Install
Summary
The Shopire theme for WordPress is vulnerable to unauthorized modification of data due to a missing capability check on the shopire_admin_install_plugin() function in all versions up to, and including, 1.0.57. This makes it possible for authenticated attackers, with Subscriber-level access and above, to install the 'fable-extra' plugin.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-02-19 21:09 UTC
CWE
  • CWE-15 - External Control of System or Configuration Setting
Impacted products
Vendor Product Version
wpfable Shopire Affected: 0 , ≤ 1.0.57 (semver)
Create a notification for this product.
Credits
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-13091",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-02-19T21:09:56.442246Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-02-19T21:10:09.099Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Shopire",
          "vendor": "wpfable",
          "versions": [
            {
              "lessThanOrEqual": "1.0.57",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Ky0toFu"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "The Shopire theme for WordPress is vulnerable to unauthorized modification of data due to a missing capability check on the shopire_admin_install_plugin() function in all versions up to, and including, 1.0.57. This makes it possible for authenticated attackers, with Subscriber-level access and above, to install the \u0027fable-extra\u0027 plugin."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 4.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-15",
              "description": "CWE-15 External Control of System or Configuration Setting",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-04-08T17:05:03.782Z",
        "orgId": "b15e7b5b-3da4-40ae-a43c-f7aa60e62599",
        "shortName": "Wordfence"
      },
      "references": [
        {
          "url": "https://www.wordfence.com/threat-intel/vulnerabilities/id/873b54ba-d29f-4e09-9dc1-a38c10ebfcb1?source=cve"
        },
        {
          "url": "https://themes.trac.wordpress.org/browser/shopire/1.0.50/inc/admin/getting-started.php"
        },
        {
          "url": "https://themes.svn.wordpress.org/shopire/1.0.50/inc/admin/getting-started.php"
        },
        {
          "url": "https://themes.trac.wordpress.org/browser/shopire/1.0.50/inc/admin/assets/js/shopire-admin-script.js"
        },
        {
          "url": "https://themes.svn.wordpress.org/shopire/1.0.50/inc/admin/assets/js/shopire-admin-script.js"
        },
        {
          "url": "https://themes.trac.wordpress.org/changeset/304732/"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2026-02-18T15:29:13.000Z",
          "value": "Disclosed"
        }
      ],
      "title": "Shopire \u003c= 1.0.57 - Missing Authorization to Authenticated (Subscriber+) Limited Plugin Install"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "b15e7b5b-3da4-40ae-a43c-f7aa60e62599",
    "assignerShortName": "Wordfence",
    "cveId": "CVE-2025-13091",
    "datePublished": "2026-02-19T04:36:18.231Z",
    "dateReserved": "2025-11-12T20:33:20.581Z",
    "dateUpdated": "2026-04-08T17:05:03.782Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-8283 (GCVE-0-2025-8283)

Vulnerability from cvelistv5 – Published: 2025-07-28 18:16 – Updated: 2026-08-21 12:46
VLAI
Title
Netavark: podman: netavark may resolve hostnames to unexpected hosts
Summary
A vulnerability was found in the netavark package, a network stack for containers used with Podman. Due to dns.podman search domain being removed, netavark may return external servers if a valid A/AAAA record is sent as a response. When creating a container with a given name, this name will be used as the hostname for the container itself, as the podman's search domain is not added anymore the container is using the host's resolv.conf, and the DNS resolver will try to look into the search domains contained on it. If one of the domains contain a name with the same hostname as the running container, the connection will forward to unexpected external servers.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-07-28 18:28 UTC
CWE
  • CWE-15 - External Control of System or Configuration Setting
Impacted products
Vendor Product Version
Affected: 0 , < 1.15.1 (semver)
Red Hat Red Hat Enterprise Linux 10     cpe:/o:redhat:enterprise_linux:10
Create a notification for this product.
Red Hat Red Hat Enterprise Linux 8     cpe:/o:redhat:enterprise_linux:8
Create a notification for this product.
Red Hat Red Hat Enterprise Linux 9     cpe:/o:redhat:enterprise_linux:9
Create a notification for this product.
Red Hat Red Hat OpenShift Container Platform 4     cpe:/a:redhat:openshift:4
Create a notification for this product.
Date Public
2025-07-28 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-8283",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-07-28T18:28:59.475895Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-07-28T18:29:12.662Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "collectionURL": "https://github.com/containers/netavark",
          "defaultStatus": "unaffected",
          "packageName": "netavark",
          "versions": [
            {
              "lessThan": "1.15.1",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "collectionURL": "https://access.redhat.com/downloads/content/package-browser/",
          "cpes": [
            "cpe:/o:redhat:enterprise_linux:10"
          ],
          "defaultStatus": "affected",
          "packageName": "netavark",
          "product": "Red Hat Enterprise Linux 10",
          "vendor": "Red Hat"
        },
        {
          "collectionURL": "https://access.redhat.com/downloads/content/package-browser/",
          "cpes": [
            "cpe:/o:redhat:enterprise_linux:8"
          ],
          "defaultStatus": "affected",
          "packageName": "container-tools:rhel8/containers-common",
          "product": "Red Hat Enterprise Linux 8",
          "vendor": "Red Hat"
        },
        {
          "collectionURL": "https://access.redhat.com/downloads/content/package-browser/",
          "cpes": [
            "cpe:/o:redhat:enterprise_linux:8"
          ],
          "defaultStatus": "affected",
          "packageName": "container-tools:rhel8/netavark",
          "product": "Red Hat Enterprise Linux 8",
          "vendor": "Red Hat"
        },
        {
          "collectionURL": "https://access.redhat.com/downloads/content/package-browser/",
          "cpes": [
            "cpe:/o:redhat:enterprise_linux:9"
          ],
          "defaultStatus": "affected",
          "packageName": "netavark",
          "product": "Red Hat Enterprise Linux 9",
          "vendor": "Red Hat"
        },
        {
          "collectionURL": "https://access.redhat.com/downloads/content/package-browser/",
          "cpes": [
            "cpe:/a:redhat:openshift:4"
          ],
          "defaultStatus": "affected",
          "packageName": "openshift/ose-rhel-coreos-9",
          "product": "Red Hat OpenShift Container Platform 4",
          "vendor": "Red Hat"
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Red Hat would like to thank Johannes Kasberger for reporting this issue."
        }
      ],
      "datePublic": "2025-07-28T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in the netavark package, a network stack for containers used with Podman. Due to dns.podman search domain being removed, netavark may return external servers if a valid A/AAAA record is sent as a response. When creating a container with a given name, this name will be used as the hostname for the container itself, as the podman\u0027s search domain is not added anymore the container is using the host\u0027s resolv.conf, and the DNS resolver will try to look into the search domains contained on it. If one of the domains contain a name with the same hostname as the running container, the connection will forward to unexpected external servers."
        }
      ],
      "metrics": [
        {
          "other": {
            "content": {
              "namespace": "https://access.redhat.com/security/updates/classification/",
              "value": "Low"
            },
            "type": "Red Hat severity rating"
          }
        },
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 3.7,
            "baseSeverity": "LOW",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-15",
              "description": "External Control of System or Configuration Setting",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-08-21T12:46:52.423Z",
        "orgId": "53f830b8-0a3f-465b-8143-3b8a9948e749",
        "shortName": "redhat"
      },
      "references": [
        {
          "tags": [
            "vdb-entry",
            "x_refsource_REDHAT"
          ],
          "url": "https://access.redhat.com/security/cve/CVE-2025-8283"
        },
        {
          "name": "RHBZ#2383941",
          "tags": [
            "issue-tracking",
            "x_refsource_REDHAT"
          ],
          "url": "https://bugzilla.redhat.com/show_bug.cgi?id=2383941"
        },
        {
          "url": "https://github.com/advisories/GHSA-rpcf-rmh6-42xr"
        },
        {
          "url": "https://github.com/containers/netavark/releases/tag/v1.15.1"
        },
        {
          "url": "https://github.com/containers/podman/issues/2619"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2025-07-28T14:15:36.417Z",
          "value": "Reported to Red Hat."
        },
        {
          "lang": "en",
          "time": "2025-07-28T00:00:00.000Z",
          "value": "Made public."
        }
      ],
      "title": "Netavark: podman: netavark may resolve hostnames to unexpected hosts",
      "workarounds": [
        {
          "lang": "en",
          "value": "As a proactive mitigation, configure containers to have hostnames formatted as \u003cname\u003e.dns.podman. This specific naming convention will prevent aardvark-dns from forwarding these queries to external search domains, thereby reducing potential exposure or unexpected network behavior associated with such queries."
        }
      ],
      "x_generator": {
        "engine": "cvelib 1.8.0"
      },
      "x_redhatCweChain": "CWE-15: External Control of System or Configuration Setting"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "53f830b8-0a3f-465b-8143-3b8a9948e749",
    "assignerShortName": "redhat",
    "cveId": "CVE-2025-8283",
    "datePublished": "2025-07-28T18:16:07.853Z",
    "dateReserved": "2025-07-28T14:16:27.236Z",
    "dateUpdated": "2026-08-21T12:46:52.423Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-0425 (GCVE-0-2025-0425)

Vulnerability from cvelistv5 – Published: 2025-02-18 07:57 – Updated: 2025-02-18 14:32
VLAI
Title
Local Privilege Escalation via Config Manipulation
Summary
Via the GUI of the "bestinformed Infoclient", a low-privileged user is by default able to change the server address of the "bestinformed Server" to which this client connects. This is dangerous as the "bestinformed Infoclient" runs with elevated permissions ("nt authority\system"). By changing the server address to a malicious server, or a script simulating a server, the user is able to escalate his privileges by abusing certain features of the "bestinformed Web" server. Those features include: * Pushing of malicious update packages * Arbitrary Registry Read as "nt authority\system" An attacker is able to escalate his privileges to "nt authority\system" on the Windows client running the "bestinformed Infoclient".  This attack is not possible if a custom configuration ("Infoclient.ini") containing the flags "ShowOnTaskbar=false" or "DisabledItems=stPort,stAddress" is deployed.
SSVC
Exploitation: none Automatable: no Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-02-18 14:31 UTC
CWE
  • CWE-15 - External Control of System or Configuration Setting
References
Impacted products
Vendor Product Version
Cordaware bestinformed Infoclient Affected: 0 , < 6.3.7.0 (custom)
Unaffected: 6.3.7.0
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-0425",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-02-18T14:31:59.558530Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-02-18T14:32:08.718Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "platforms": [
            "Windows"
          ],
          "product": "bestinformed Infoclient",
          "vendor": "Cordaware",
          "versions": [
            {
              "lessThan": "6.3.7.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            },
            {
              "status": "unaffected",
              "version": "6.3.7.0"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Manuel Kiesel (cyllective AG)"
        },
        {
          "lang": "en",
          "type": "finder",
          "value": "David Miller (cyllective AG)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Via the GUI of the \"bestinformed Infoclient\", a low-privileged user is by default able to change the server address of the \"bestinformed Server\" to which this client connects. This is dangerous as the \"bestinformed Infoclient\" runs with elevated permissions (\"nt authority\\system\"). By changing the server address to a malicious server, or a script simulating a server, the user is able to escalate his privileges by abusing certain features of the \"bestinformed Web\" server. Those features include:\u003cbr\u003e\u003cul\u003e\u003cli\u003ePushing of malicious update packages\u003c/li\u003e\u003cli\u003eArbitrary Registry Read as \"nt authority\\system\"\u003c/li\u003e\u003c/ul\u003eAn attacker is able to escalate his privileges to \"nt authority\\system\" on the Windows client running the \"bestinformed Infoclient\".\u0026nbsp;\u003cdiv\u003e\u003cbr\u003e\u003c/div\u003e\u003cdiv\u003eThis attack is not possible if a custom configuration \u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e(\"\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eInfoclient.ini\")\u0026nbsp;\u003c/span\u003econtaining the flags \"ShowOnTaskbar=false\" or \"DisabledItems=stPort,stAddress\" is deployed.\u0026nbsp;\u003cbr\u003e\u003c/div\u003e"
            }
          ],
          "value": "Via the GUI of the \"bestinformed Infoclient\", a low-privileged user is by default able to change the server address of the \"bestinformed Server\" to which this client connects. This is dangerous as the \"bestinformed Infoclient\" runs with elevated permissions (\"nt authority\\system\"). By changing the server address to a malicious server, or a script simulating a server, the user is able to escalate his privileges by abusing certain features of the \"bestinformed Web\" server. Those features include:\n  *  Pushing of malicious update packages\n  *  Arbitrary Registry Read as \"nt authority\\system\"\n\n\nAn attacker is able to escalate his privileges to \"nt authority\\system\" on the Windows client running the \"bestinformed Infoclient\".\u00a0\n\n\nThis attack is not possible if a custom configuration (\"Infoclient.ini\")\u00a0containing the flags \"ShowOnTaskbar=false\" or \"DisabledItems=stPort,stAddress\" is deployed."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-233",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-233 Privilege Escalation"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "LOCAL",
            "baseScore": 8.5,
            "baseSeverity": "HIGH",
            "privilegesRequired": "LOW",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-15",
              "description": "CWE-15: External Control of System or Configuration Setting",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-02-18T07:57:35.329Z",
        "orgId": "455daabc-a392-441d-aa46-37d35189897c",
        "shortName": "NCSC.ch"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.cordaware.com/changelog/en/version-6_3_8_1.html"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Local Privilege Escalation via Config Manipulation",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "455daabc-a392-441d-aa46-37d35189897c",
    "assignerShortName": "NCSC.ch",
    "cveId": "CVE-2025-0425",
    "datePublished": "2025-02-18T07:57:35.329Z",
    "dateReserved": "2025-01-13T14:29:50.604Z",
    "dateUpdated": "2025-02-18T14:32:08.718Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-54097 (GCVE-0-2024-54097)

Vulnerability from cvelistv5 – Published: 2024-12-12 11:11 – Updated: 2024-12-12 15:22
VLAI
Summary
Security vulnerability in the HiView module Impact: Successful exploitation of this vulnerability may affect feature implementation and integrity.
SSVC
Exploitation: none Automatable: no Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-12-12 15:22 UTC
CWE
  • CWE-15 - External Control of System or Configuration Setting
Impacted products
Vendor Product Version
Huawei HarmonyOS Affected: 4.2.0
Affected: 4.0.0
Affected: 3.1.0
Affected: 3.0.0
Affected: 2.1.0
Affected: 2.0.0
Create a notification for this product.
Huawei EMUI Affected: 14.0.0
Affected: 13.0.0
Affected: 12.0.0
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-54097",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-12-12T15:22:24.038540Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-12-12T15:22:50.608Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "HarmonyOS",
          "vendor": "Huawei",
          "versions": [
            {
              "status": "affected",
              "version": "4.2.0"
            },
            {
              "status": "affected",
              "version": "4.0.0"
            },
            {
              "status": "affected",
              "version": "3.1.0"
            },
            {
              "status": "affected",
              "version": "3.0.0"
            },
            {
              "status": "affected",
              "version": "2.1.0"
            },
            {
              "status": "affected",
              "version": "2.0.0"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "EMUI",
          "vendor": "Huawei",
          "versions": [
            {
              "status": "affected",
              "version": "14.0.0"
            },
            {
              "status": "affected",
              "version": "13.0.0"
            },
            {
              "status": "affected",
              "version": "12.0.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Security vulnerability in the HiView module\u003cbr\u003eImpact: Successful exploitation of this vulnerability may affect feature implementation and integrity."
            }
          ],
          "value": "Security vulnerability in the HiView module\nImpact: Successful exploitation of this vulnerability may affect feature implementation and integrity."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "PHYSICAL",
            "availabilityImpact": "NONE",
            "baseScore": 7.3,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-15",
              "description": "CWE-15 External Control of System or Configuration Setting",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-12-12T11:11:58.118Z",
        "orgId": "25ac1063-e409-4190-8079-24548c77ea2e",
        "shortName": "huawei"
      },
      "references": [
        {
          "url": "https://consumer.huawei.com/en/support/bulletin/2024/12/"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "25ac1063-e409-4190-8079-24548c77ea2e",
    "assignerShortName": "huawei",
    "cveId": "CVE-2024-54097",
    "datePublished": "2024-12-12T11:11:58.118Z",
    "dateReserved": "2024-11-29T02:34:46.789Z",
    "dateUpdated": "2024-12-12T15:22:50.608Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-51544 (GCVE-0-2024-51544)

Vulnerability from cvelistv5 – Published: 2024-12-05 12:48 – Updated: 2024-12-05 14:50
VLAI
Title
Service Control
Summary
Service Control vulnerabilities allow access to service restart requests and vm configuration settings.  Affected products: ABB ASPECT - Enterprise v3.08.02; NEXUS Series v3.08.02; MATRIX Series v3.08.02
SSVC
Exploitation: none Automatable: yes Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-12-05 14:48 UTC
CWE
  • CWE-15 - External Control of System or Configuration Setting
Impacted products
Vendor Product Version
ABB ASPECT-Enterprise Affected: 0 , ≤ 3.08.02 (custom)
Create a notification for this product.
ABB NEXUS Series Affected: 0 , ≤ 3.08.02 (custom)
Create a notification for this product.
ABB MATRIX Series Affected: 0 , ≤ 3.08.02 (custom)
Create a notification for this product.
abb nexus_series Affected: 0 , ≤ 3.08.02 (custom)
    cpe:2.3:a:abb:nexus_series:*:*:*:*:*:*:*:*
Create a notification for this product.
abb matrix_series Affected: 0 , ≤ 3.08.02 (custom)
    cpe:2.3:a:abb:matrix_series:*:*:*:*:*:*:*:*
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:abb:nexus_series:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "nexus_series",
            "vendor": "abb",
            "versions": [
              {
                "lessThanOrEqual": "3.08.02",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:abb:nexus_series:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "nexus_series",
            "vendor": "abb",
            "versions": [
              {
                "lessThanOrEqual": "3.08.02",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:abb:matrix_series:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "matrix_series",
            "vendor": "abb",
            "versions": [
              {
                "lessThanOrEqual": "3.08.02",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-51544",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-12-05T14:48:07.626886Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-12-05T14:50:27.895Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "platforms": [
            "Linux"
          ],
          "product": "ASPECT-Enterprise",
          "vendor": "ABB",
          "versions": [
            {
              "lessThanOrEqual": "3.08.02",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "platforms": [
            "Linux"
          ],
          "product": "NEXUS Series",
          "vendor": "ABB",
          "versions": [
            {
              "lessThanOrEqual": "3.08.02",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "platforms": [
            "Linux"
          ],
          "product": "MATRIX Series",
          "vendor": "ABB",
          "versions": [
            {
              "lessThanOrEqual": "3.08.02",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "ABB likes to thank Gjoko Krstikj, Zero Science Lab, for reporting the vulnerabilities in responsible disclosure"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Service Control vulnerabilities allow access to service restart requests and vm configuration settings.\u0026nbsp;\u003cbr\u003eAffected products:\u003cbr\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eABB ASPECT - Enterprise v3.08.02; \u003cbr\u003eNEXUS Series v3.08.02; \u003cbr\u003eMATRIX Series v3.08.02\u003c/span\u003e\u003cbr\u003e"
            }
          ],
          "value": "Service Control vulnerabilities allow access to service restart requests and vm configuration settings.\u00a0\nAffected products:\n\n\nABB ASPECT - Enterprise v3.08.02; \nNEXUS Series v3.08.02; \nMATRIX Series v3.08.02"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 8.2,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "LOW",
            "subConfidentialityImpact": "LOW",
            "subIntegrityImpact": "LOW",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:L/VA:H/SC:L/SI:L/SA:L",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "NONE",
            "vulnIntegrityImpact": "LOW",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-15",
              "description": "CWE-15 External Control of System or Configuration Setting",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-12-05T12:48:32.801Z",
        "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "shortName": "ABB"
      },
      "references": [
        {
          "url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK108469A7497\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Service Control",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
    "assignerShortName": "ABB",
    "cveId": "CVE-2024-51544",
    "datePublished": "2024-12-05T12:48:32.801Z",
    "dateReserved": "2024-10-29T11:48:54.542Z",
    "dateUpdated": "2024-12-05T14:50:27.895Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-51543 (GCVE-0-2024-51543)

Vulnerability from cvelistv5 – Published: 2024-12-05 12:47 – Updated: 2024-12-05 14:53
VLAI
Title
Information Disclosure
Summary
Information Disclosure vulnerabilities allow access to application configuration information.  Affected products: ABB ASPECT - Enterprise v3.08.02; NEXUS Series v3.08.02; MATRIX Series v3.08.02
SSVC
Exploitation: none Automatable: yes Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-12-05 14:51 UTC
CWE
  • CWE-15 - External Control of System or Configuration Setting
Impacted products
Vendor Product Version
ABB ASPECT-Enterprise Affected: 0 , ≤ 3.08.02 (custom)
Create a notification for this product.
ABB NEXUS Series Affected: 0 , ≤ 3.08.02 (custom)
Create a notification for this product.
ABB MATRIX Series Affected: 0 , ≤ 3.08.02 (custom)
Create a notification for this product.
abb aspect_enterprise Affected: 0 , ≤ 3.08.02 (custom)
    cpe:2.3:a:abb:aspect_enterprise:*:*:*:*:*:*:*:*
Create a notification for this product.
abb nexus_series Affected: 0 , < 3.08.02 (custom)
    cpe:2.3:a:abb:nexus_series:*:*:*:*:*:*:*:*
Create a notification for this product.
abb matrix_series Affected: 0 , < 3.08.02 (custom)
    cpe:2.3:a:abb:matrix_series:*:*:*:*:*:*:*:*
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:abb:aspect_enterprise:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "aspect_enterprise",
            "vendor": "abb",
            "versions": [
              {
                "lessThanOrEqual": "3.08.02",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:abb:nexus_series:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "nexus_series",
            "vendor": "abb",
            "versions": [
              {
                "lessThan": "3.08.02",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:abb:matrix_series:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "matrix_series",
            "vendor": "abb",
            "versions": [
              {
                "lessThan": "3.08.02",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-51543",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-12-05T14:51:25.818780Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-12-05T14:53:38.763Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "platforms": [
            "Linux"
          ],
          "product": "ASPECT-Enterprise",
          "vendor": "ABB",
          "versions": [
            {
              "lessThanOrEqual": "3.08.02",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "platforms": [
            "Linux"
          ],
          "product": "NEXUS Series",
          "vendor": "ABB",
          "versions": [
            {
              "lessThanOrEqual": "3.08.02",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "platforms": [
            "Linux"
          ],
          "product": "MATRIX Series",
          "vendor": "ABB",
          "versions": [
            {
              "lessThanOrEqual": "3.08.02",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "ABB likes to thank Gjoko Krstikj, Zero Science Lab, for reporting the vulnerabilities in responsible disclosure"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Information Disclosure vulnerabilities allow access to application configuration information.\u0026nbsp;\u003cbr\u003eAffected products:\u003cbr\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eABB ASPECT - Enterprise v3.08.02; \u003cbr\u003eNEXUS Series v3.08.02; \u003cbr\u003eMATRIX Series v3.08.02\u003c/span\u003e\u003cbr\u003e"
            }
          ],
          "value": "Information Disclosure vulnerabilities allow access to application configuration information.\u00a0\nAffected products:\n\n\nABB ASPECT - Enterprise v3.08.02; \nNEXUS Series v3.08.02; \nMATRIX Series v3.08.02"
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "LOW",
            "subConfidentialityImpact": "LOW",
            "subIntegrityImpact": "LOW",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:L/VA:N/SC:L/SI:L/SA:L",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "LOW",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 8.2,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-15",
              "description": "CWE-15 External Control of System or Configuration Setting",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-12-05T12:47:06.288Z",
        "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "shortName": "ABB"
      },
      "references": [
        {
          "url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK108469A7497\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Information Disclosure",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
    "assignerShortName": "ABB",
    "cveId": "CVE-2024-51543",
    "datePublished": "2024-12-05T12:47:06.288Z",
    "dateReserved": "2024-10-29T11:48:54.542Z",
    "dateUpdated": "2024-12-05T14:53:38.763Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-50358 (GCVE-0-2024-50358)

Vulnerability from cvelistv5 – Published: 2024-11-26 10:51 – Updated: 2024-11-26 14:19
VLAI
Summary
A CWE-15 "External Control of System or Configuration Setting" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The vulnerability can be exploited by authenticated users by restoring a tampered configuration backup.
SSVC
Exploitation: none Automatable: no Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-11-26 14:12 UTC
CWE
  • CWE-15 - External Control of System or Configuration Setting
Impacted products
Vendor Product Version
Advantech EKI-6333AC-2G Affected: 0 , ≤ <= 1.6.3 (semver)
Create a notification for this product.
Advantech EKI-6333AC-2GD Affected: 0 , ≤ <= 1.6.3 (semver)
Create a notification for this product.
Advantech EKI-6333AC-1GPO Affected: 0 , ≤ <= 1.2.1 (semver)
Create a notification for this product.
advantech eki-6333ac-2g_firmware Affected: 0 , ≤ 1.6.3 (custom)
    cpe:2.3:o:advantech:eki-6333ac-2g_firmware:*:*:*:*:*:*:*:*
Create a notification for this product.
advantech eki-6333ac-2gd_firmware Affected: 0 , ≤ 1.6.3 (custom)
    cpe:2.3:o:advantech:eki-6333ac-2gd_firmware:*:*:*:*:*:*:*:*
Create a notification for this product.
advantech eki-6333ac-1gpo_firmware Affected: 0 , ≤ 1.2.1 (custom)
    cpe:2.3:o:advantech:eki-6333ac-1gpo_firmware:*:*:*:*:*:*:*:*
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:advantech:eki-6333ac-2g_firmware:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "eki-6333ac-2g_firmware",
            "vendor": "advantech",
            "versions": [
              {
                "lessThanOrEqual": "1.6.3",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:advantech:eki-6333ac-2gd_firmware:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "eki-6333ac-2gd_firmware",
            "vendor": "advantech",
            "versions": [
              {
                "lessThanOrEqual": "1.6.3",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:advantech:eki-6333ac-1gpo_firmware:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "eki-6333ac-1gpo_firmware",
            "vendor": "advantech",
            "versions": [
              {
                "lessThanOrEqual": "1.2.1",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-50358",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-11-26T14:12:13.343659Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-11-26T14:19:27.283Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "EKI-6333AC-2G",
          "vendor": "Advantech",
          "versions": [
            {
              "lessThanOrEqual": "\u003c= 1.6.3",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "EKI-6333AC-2GD",
          "vendor": "Advantech",
          "versions": [
            {
              "lessThanOrEqual": "\u003c= 1.6.3",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "EKI-6333AC-1GPO",
          "vendor": "Advantech",
          "versions": [
            {
              "lessThanOrEqual": "\u003c= 1.2.1",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Diego Zaffaroni of Nozomi Networks found this bug during a security research activity."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "A CWE-15 \"External Control of System or Configuration Setting\" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (\u0026lt;= 1.6.3), EKI-6333AC-2GD (\u0026lt;= v1.6.3) and EKI-6333AC-1GPO (\u0026lt;= v1.2.1). The vulnerability can be exploited by authenticated users by restoring a tampered configuration backup.\u003cbr\u003e"
            }
          ],
          "value": "A CWE-15 \"External Control of System or Configuration Setting\" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (\u003c= 1.6.3), EKI-6333AC-2GD (\u003c= v1.6.3) and EKI-6333AC-1GPO (\u003c= v1.2.1). The vulnerability can be exploited by authenticated users by restoring a tampered configuration backup."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.2,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-15",
              "description": "CWE-15 External Control of System or Configuration Setting",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-11-26T11:24:35.036Z",
        "orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
        "shortName": "Nozomi"
      },
      "references": [
        {
          "url": "https://www.nozominetworks.com/labs/vulnerability-advisories-cve-2024-50358"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Update affected products to the following firmware versions released by Advantech:\u003cbr\u003e- EKI-6333AC-2G: v1.6.5\u003cbr\u003e- EKI-6333AC-2GD: v1.6.5\u003cbr\u003e- EKI-6333AC-1GPO: v1.2.2"
            }
          ],
          "value": "Update affected products to the following firmware versions released by Advantech:\n- EKI-6333AC-2G: v1.6.5\n- EKI-6333AC-2GD: v1.6.5\n- EKI-6333AC-1GPO: v1.2.2"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
    "assignerShortName": "Nozomi",
    "cveId": "CVE-2024-50358",
    "datePublished": "2024-11-26T10:51:50.451Z",
    "dateReserved": "2024-10-23T07:55:56.654Z",
    "dateUpdated": "2024-11-26T14:19:27.283Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-39800 (GCVE-0-2024-39800)

Vulnerability from cvelistv5 – Published: 2025-01-14 14:21 – Updated: 2025-11-03 21:57
VLAI
Summary
Multiple external config control vulnerabilities exists in the openvpn.cgi openvpn_server_setup() functionality of Wavlink AC3000 M33A8.V5030.210505. A specially crafted HTTP request can lead to arbitrary command execution. An attacker can make an authenticated HTTP request to trigger these vulnerabilities.A configuration injection vulnerability exists in the `open_port` POST parameter.
SSVC
Exploitation: none Automatable: no Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-01-15 20:36 UTC
CWE
  • CWE-15 - External Control of System or Configuration Setting
Impacted products
Vendor Product Version
Wavlink Wavlink AC3000 Affected: M33A8.V5030.210505
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-39800",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-01-15T20:36:00.581142Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-01-15T20:36:13.302Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2025-11-03T21:57:11.047Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2024-2050"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Wavlink AC3000",
          "vendor": "Wavlink",
          "versions": [
            {
              "status": "affected",
              "version": "M33A8.V5030.210505"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Discovered by Lilith \u0026gt;_\u0026gt; of Cisco Talos."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Multiple external config control vulnerabilities exists in the openvpn.cgi openvpn_server_setup() functionality of Wavlink AC3000 M33A8.V5030.210505. A specially crafted HTTP request can lead to arbitrary command execution. An attacker can make an authenticated HTTP request to trigger these vulnerabilities.A configuration injection vulnerability exists in the `open_port` POST parameter."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.1,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-15",
              "description": "CWE-15: External Control of System or Configuration Setting",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-01-14T14:21:02.899Z",
        "orgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
        "shortName": "talos"
      },
      "references": [
        {
          "name": "https://talosintelligence.com/vulnerability_reports/TALOS-2024-2050",
          "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2024-2050"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
    "assignerShortName": "talos",
    "cveId": "CVE-2024-39800",
    "datePublished": "2025-01-14T14:21:02.899Z",
    "dateReserved": "2024-06-28T18:05:54.343Z",
    "dateUpdated": "2025-11-03T21:57:11.047Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

Mitigation MIT-46
Architecture and Design

Strategy: Separation of Privilege

  • Compartmentalize the system to have "safe" areas where trust boundaries can be unambiguously drawn. Do not allow sensitive data to go outside of the trust boundary and always be careful when interfacing with a compartment outside of the safe area.
  • Ensure that appropriate compartmentalization is built into the system design, and the compartmentalization allows for and reinforces privilege separation functionality. Architects and designers should rely on the principle of least privilege to decide the appropriate time to use privileges and the time to drop privileges.
Mitigation
Implementation Architecture and Design

Because setting manipulation covers a diverse set of functions, any attempt at illustrating it will inevitably be incomplete. Rather than searching for a tight-knit relationship between the functions addressed in the setting manipulation category, take a step back and consider the sorts of system values that an attacker should not be allowed to control.

Mitigation
Implementation Architecture and Design

In general, do not allow user-provided or otherwise untrusted data to control sensitive values. The leverage that an attacker gains by controlling these values is not always immediately obvious, but do not underestimate the creativity of the attacker.

CAPEC-13: Subverting Environment Variable Values

The adversary directly or indirectly modifies environment variables used by or controlling the target software. The adversary's goal is to cause the target software to deviate from its expected operation in a manner that benefits the adversary.

CAPEC-146: XML Schema Poisoning

An adversary corrupts or modifies the content of XML schema information passed between a client and server for the purpose of undermining the security of the target. XML Schemas provide the structure and content definitions for XML documents. Schema poisoning is the ability to manipulate a schema either by replacing or modifying it to compromise the programs that process documents that use this schema.

CAPEC-176: Configuration/Environment Manipulation

An attacker manipulates files or settings external to a target application which affect the behavior of that application. For example, many applications use external configuration files and libraries - modification of these entities or otherwise affecting the application's ability to use them would constitute a configuration/environment manipulation attack.

CAPEC-203: Manipulate Registry Information

An adversary exploits a weakness in authorization in order to modify content within a registry (e.g., Windows Registry, Mac plist, application registry). Editing registry information can permit the adversary to hide configuration information or remove indicators of compromise to cover up activity. Many applications utilize registries to store configuration and service information. As such, modification of registry information can affect individual services (affecting billing, authorization, or even allowing for identity spoofing) or the overall configuration of a targeted application. For example, both Java RMI and SOAP use registries to track available services. Changing registry values is sometimes a preliminary step towards completing another attack pattern, but given the long term usage of many registry values, manipulation of registry information could be its own end.

CAPEC-270: Modification of Registry Run Keys

An adversary adds a new entry to the "run keys" in the Windows registry so that an application of their choosing is executed when a user logs in. In this way, the adversary can get their executable to operate and run on the target system with the authorized user's level of permissions. This attack is a good way for an adversary to run persistent spyware on a user's machine, such as a keylogger.

CAPEC-271: Schema Poisoning

An adversary corrupts or modifies the content of a schema for the purpose of undermining the security of the target. Schemas provide the structure and content definitions for resources used by an application. By replacing or modifying a schema, the adversary can affect how the application handles or interprets a resource, often leading to possible denial of service, entering into an unexpected state, or recording incomplete data.

CAPEC-579: Replace Winlogon Helper DLL

Winlogon is a part of Windows that performs logon actions. In Windows systems prior to Windows Vista, a registry key can be modified that causes Winlogon to load a DLL on startup. Adversaries may take advantage of this feature to load adversarial code at startup.

CAPEC-69: Target Programs with Elevated Privileges

This attack targets programs running with elevated privileges. The adversary tries to leverage a vulnerability in the running program and get arbitrary code to execute with elevated privileges.

CAPEC-76: Manipulating Web Input to File System Calls

An attacker manipulates inputs to the target software which the target software passes to file system calls in the OS. The goal is to gain access to, and perhaps modify, areas of the file system that the target software did not intend to be accessible.

CAPEC-77: Manipulating User-Controlled Variables

This attack targets user controlled variables (DEBUG=1, PHP Globals, and So Forth). An adversary can override variables leveraging user-supplied, untrusted query variables directly used on the application server without any data sanitization. In extreme cases, the adversary can change variables controlling the business logic of the application. For instance, in languages like PHP, a number of poorly set default configurations may allow the user to override variables.