Common Weakness Enumeration

CWE-1285

Allowed

Improper Validation of Specified Index, Position, or Offset in Input

Abstraction: Base · Status: Incomplete

The product receives input that is expected to specify an index, position, or offset into an indexable resource such as a buffer or file, but it does not validate or incorrectly validates that the specified index/position/offset has the required properties.

111 vulnerabilities reference this CWE, most recent first.

CVE-2025-55087 (GCVE-0-2025-55087)

Vulnerability from cvelistv5 – Published: 2025-10-17 06:03 – Updated: 2025-10-17 13:07
VLAI
Summary
In NextX Duo's snmp addon versions before 6.4.4, a part of the Eclipse Foundation ThreadX, an attacker could cause an out-of-bound read by a crafted SNMPv3 security parameters.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-10-17 13:07 UTC
CWE
  • CWE-1285 - Improper Validation of Specified Index, Position, or Offset in Input
  • CWE-125 - Out-of-bounds Read
Assigner
eclipse CNA under the mitre root
CNA scorecard C 63/100 over 146 records in the last 180 days details
References
Impacted products
Vendor Product Version
Eclipse Foundation NextX Duo Affected: 0 , < 6.4.4 (semver)
Create a notification for this product.
Credits
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-55087",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-10-17T13:07:00.905492Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-10-17T13:07:14.994Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "NextX Duo",
          "repo": "https://github.com/eclipse-threadx/netxduo/",
          "vendor": "Eclipse Foundation",
          "versions": [
            {
              "lessThan": "6.4.4",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "ekleezg"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "In NextX Duo\u0027s snmp addon versions before 6.4.4, a part of the Eclipse Foundation ThreadX, an attacker could cause an out-of-bound read by a crafted SNMPv3 security parameters.\u003cbr\u003e"
            }
          ],
          "value": "In NextX Duo\u0027s snmp addon versions before 6.4.4, a part of the Eclipse Foundation ThreadX, an attacker could cause an out-of-bound read by a crafted SNMPv3 security parameters."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "PRESENT",
            "attackVector": "NETWORK",
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "LOW",
            "vulnConfidentialityImpact": "LOW",
            "vulnIntegrityImpact": "LOW",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1285",
              "description": "CWE-1285: Improper Validation of Specified Index, Position, or Offset in Input",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-125",
              "description": "CWE-125 Out-of-bounds Read",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-10-17T06:03:14.098Z",
        "orgId": "e51fbebd-6053-4e49-959f-1b94eeb69a2c",
        "shortName": "eclipse"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://github.com/eclipse-threadx/netxduo/security/advisories/GHSA-v474-mv4g-v8cx"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "e51fbebd-6053-4e49-959f-1b94eeb69a2c",
    "assignerShortName": "eclipse",
    "cveId": "CVE-2025-55087",
    "datePublished": "2025-10-17T06:03:14.098Z",
    "dateReserved": "2025-08-06T18:32:14.667Z",
    "dateUpdated": "2025-10-17T13:07:14.994Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-55086 (GCVE-0-2025-55086)

Vulnerability from cvelistv5 – Published: 2025-10-20 17:49 – Updated: 2025-10-20 20:23
VLAI
Summary
In NetXDuo version before 6.4.4, a networking support module for Eclipse Foundation ThreadX, in the DHCPV6 client there was an unchecked index extracting the server DUID from the server reply. With a crafted packet, an attacker could cause an out of memory read.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-10-20 20:23 UTC
CWE
Assigner
eclipse CNA under the mitre root
CNA scorecard C 63/100 over 146 records in the last 180 days details
Impacted products
Vendor Product Version
Eclipse Foundation NextX Duo Affected: 0 , < 6.4.4 (semver)
Create a notification for this product.
Credits
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-55086",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-10-20T20:23:06.785452Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-10-20T20:23:18.104Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "NextX Duo",
          "vendor": "Eclipse Foundation",
          "versions": [
            {
              "lessThan": "6.4.4",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "ekleezg"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "In NetXDuo version before 6.4.4, a networking support module for Eclipse Foundation ThreadX, in the DHCPV6 client there was an unchecked index extracting the server DUID from the server reply. With a crafted packet, an attacker could cause an out of memory read.\u003cbr\u003e"
            }
          ],
          "value": "In NetXDuo version before 6.4.4, a networking support module for Eclipse Foundation ThreadX, in the DHCPV6 client there was an unchecked index extracting the server DUID from the server reply. With a crafted packet, an attacker could cause an out of memory read."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "PRESENT",
            "attackVector": "NETWORK",
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:N/VI:L/VA:L/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "LOW",
            "vulnConfidentialityImpact": "NONE",
            "vulnIntegrityImpact": "LOW",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1285",
              "description": "CWE-1285",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-125",
              "description": "CWE-125 Out-of-bounds Read",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-10-20T17:49:29.647Z",
        "orgId": "e51fbebd-6053-4e49-959f-1b94eeb69a2c",
        "shortName": "eclipse"
      },
      "references": [
        {
          "url": "https://github.com/eclipse-threadx/netxduo/security/advisories/GHSA-99pw-cp79-2j5j"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "e51fbebd-6053-4e49-959f-1b94eeb69a2c",
    "assignerShortName": "eclipse",
    "cveId": "CVE-2025-55086",
    "datePublished": "2025-10-20T17:49:29.647Z",
    "dateReserved": "2025-08-06T18:32:14.667Z",
    "dateUpdated": "2025-10-20T20:23:18.104Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-48511 (GCVE-0-2025-48511)

Vulnerability from cvelistv5 – Published: 2025-11-24 21:00 – Updated: 2025-11-24 21:13
VLAI
Summary
Improper input validation within AMD uprof can allow a local attacker to write to an arbitrary physical address, potentially resulting in crash or denial of service.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-11-24 21:12 UTC
CWE
  • CWE-1285 - Improper Validation of Specified Index, Position, or Offset in Input
Assigner
AMD CNA under the mitre root
CNA scorecard C 63/100 over 74 records in the last 180 days details
Impacted products
Vendor Product Version
AMD AMD μProf Unaffected: 5.0
Create a notification for this product.
Date Public
2025-11-24 21:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-48511",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-11-24T21:12:56.753582Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-11-24T21:13:33.411Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "affected",
          "product": "AMD \u03bcProf",
          "vendor": "AMD",
          "versions": [
            {
              "status": "unaffected",
              "version": "5.0"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Reported through AMD Bug Bounty Program"
        }
      ],
      "datePublic": "2025-11-24T21:00:11.556Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Improper input validation within AMD uprof can allow a local attacker to write to an arbitrary physical address, potentially resulting in crash or denial of service. \u003cbr\u003e"
            }
          ],
          "value": "Improper input validation within AMD uprof can allow a local attacker to write to an arbitrary physical address, potentially resulting in crash or denial of service."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 5.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1285",
              "description": "CWE-1285  Improper Validation of Specified Index, Position, or Offset in Input",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-11-24T21:00:32.010Z",
        "orgId": "b58fc414-a1e4-4f92-9d70-1add41838648",
        "shortName": "AMD"
      },
      "references": [
        {
          "url": "https://www.amd.com/en/resources/product-security/bulletin/AMD-SB-9019.html"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "AMD PSIRT Automation 1.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "b58fc414-a1e4-4f92-9d70-1add41838648",
    "assignerShortName": "AMD",
    "cveId": "CVE-2025-48511",
    "datePublished": "2025-11-24T21:00:32.010Z",
    "dateReserved": "2025-05-22T16:34:02.896Z",
    "dateUpdated": "2025-11-24T21:13:33.411Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-48502 (GCVE-0-2025-48502)

Vulnerability from cvelistv5 – Published: 2025-11-21 19:07 – Updated: 2025-11-24 21:02
VLAI
Summary
Improper input validation within AMD uprof can allow a local attacker to overwrite MSR registers, potentially resulting in crash or denial of service.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-11-21 19:19 UTC
CWE
  • CWE-1285 - Improper Validation of Specified Index, Position, or Offset in Input
Assigner
AMD CNA under the mitre root
CNA scorecard C 63/100 over 74 records in the last 180 days details
Impacted products
Vendor Product Version
AMD AMD μProf Unaffected: 5.0
Create a notification for this product.
Date Public
2025-11-24 21:02
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-48502",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-11-21T19:19:08.282013Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-11-21T19:19:29.196Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "affected",
          "product": "AMD \u03bcProf",
          "vendor": "AMD",
          "versions": [
            {
              "status": "unaffected",
              "version": "5.0"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Reported through AMD Bug Bounty Program"
        }
      ],
      "datePublic": "2025-11-24T21:02:15.564Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Improper input validation within AMD uprof can allow a local attacker to overwrite MSR registers, potentially resulting in crash or denial of service. \u003cbr\u003e"
            }
          ],
          "value": "Improper input validation within AMD uprof can allow a local attacker to overwrite MSR registers, potentially resulting in crash or denial of service."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 5.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1285",
              "description": "CWE-1285  Improper Validation of Specified Index, Position, or Offset in Input",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-11-24T21:02:33.311Z",
        "orgId": "b58fc414-a1e4-4f92-9d70-1add41838648",
        "shortName": "AMD"
      },
      "references": [
        {
          "url": "https://www.amd.com/en/resources/product-security/bulletin/AMD-SB-9019.html"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "AMD PSIRT Automation 1.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "b58fc414-a1e4-4f92-9d70-1add41838648",
    "assignerShortName": "AMD",
    "cveId": "CVE-2025-48502",
    "datePublished": "2025-11-21T19:07:34.889Z",
    "dateReserved": "2025-05-22T16:34:02.895Z",
    "dateUpdated": "2025-11-24T21:02:33.311Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-20796 (GCVE-0-2025-20796)

Vulnerability from cvelistv5 – Published: 2026-01-06 01:46 – Updated: 2026-03-30 13:04
VLAI
Summary
In imgsys, there is a possible out of bounds write due to improper input validation. This could lead to local escalation of privilege if a malicious actor has already obtained the System privilege. User interaction is needed for exploitation. Patch ID: ALPS10314745; Issue ID: MSV-5553.
SSVC
Exploitation: none Automatable: no Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-01-07 04:55 UTC
CWE
  • CWE-1285 - Specified Index, Position, or Offset
Assigner
MediaTek CNA under the mitre root
CNA scorecard D 45/100 over 100 records in the last 180 days details
Impacted products
Vendor Product Version
MediaTek, Inc. MediaTek chipset Affected: MT6989
Affected: MT8796
Affected: MT8893
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "LOCAL",
              "availabilityImpact": "HIGH",
              "baseScore": 7.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2025-20796",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-01-07T04:55:47.977874Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-02-26T15:04:59.230Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "MediaTek chipset",
          "vendor": "MediaTek, Inc.",
          "versions": [
            {
              "status": "affected",
              "version": "MT6989"
            },
            {
              "status": "affected",
              "version": "MT8796"
            },
            {
              "status": "affected",
              "version": "MT8893"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "In imgsys, there is a possible out of bounds write due to improper input validation. This could lead to local escalation of privilege if a malicious actor has already obtained the System privilege. User interaction is needed for exploitation. Patch ID: ALPS10314745; Issue ID: MSV-5553."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1285",
              "description": "CWE-1285 Specified Index, Position, or Offset",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-03-30T13:04:08.419Z",
        "orgId": "ee979b05-11f8-4f25-a7e0-a1fa9c190374",
        "shortName": "MediaTek"
      },
      "references": [
        {
          "url": "https://corp.mediatek.com/product-security-bulletin/January-2026"
        }
      ],
      "x_generator": {
        "engine": "cvelib 1.8.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "ee979b05-11f8-4f25-a7e0-a1fa9c190374",
    "assignerShortName": "MediaTek",
    "cveId": "CVE-2025-20796",
    "datePublished": "2026-01-06T01:46:40.242Z",
    "dateReserved": "2024-11-01T01:21:50.403Z",
    "dateUpdated": "2026-03-30T13:04:08.419Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-9189 (GCVE-0-2025-9189)

Vulnerability from cvelistv5 – Published: 2025-09-02 18:12 – Updated: 2026-09-03 16:14
VLAI
Title
Out Of Bounds Write when parsing a DSB file with Digilent DASYLab
Summary
There is an out of bounds write vulnerability due to improper bounds checking resulting in a large destination address when parsing a DSB file with Digilent DASYLab. This vulnerability may result in arbitrary code execution. Successful exploitation requires an attacker to get a user to open a specially crafted DSB file. The vulnerability affects all versions of DASYLab.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-09-02 19:46 UTC
CWE
  • CWE-1285 - Improper Validation of Specified Index, Position, or Offset in Input
Assigner
NI CNA under the mitre root
CNA scorecard B 84/100 over 28 records in the last 180 days details
Impacted products
Vendor Product Version
Digilent DASYLab Affected: 0 , ≤ * (semver)
    cpe:2.3:a:digilent:dasylab:*:*:*:*:*:*:*:*
Create a notification for this product.
measX DASYLab Unaffected: 2026.0.0 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-9189",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-09-02T19:46:39.562817Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-09-02T19:46:46.564Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "DASYLab",
          "vendor": "Digilent",
          "versions": [
            {
              "lessThanOrEqual": "*",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "DASYLab",
          "vendor": "measX",
          "versions": [
            {
              "status": "unaffected",
              "version": "2026.0.0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "cpeApplicability": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:digilent:dasylab:*:*:*:*:*:*:*:*",
                  "versionEndIncluding": "*",
                  "versionStartIncluding": "0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:measx:dasylab:2026.0.0:*:*:*:*:*:*:*",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "OR"
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "kimiya working with Trend Micro Zero Day Initiative"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eThere is an out of bounds write vulnerability due to improper bounds checking resulting in a large destination address when parsing a DSB file with Digilent DASYLab.  This vulnerability may result in arbitrary code execution.  Successful exploitation requires an attacker to get a user to open a specially crafted DSB file.  The vulnerability affects all versions of DASYLab.\u003c/p\u003e"
            }
          ],
          "value": "There is an out of bounds write vulnerability due to improper bounds checking resulting in a large destination address when parsing a DSB file with Digilent DASYLab.  This vulnerability may result in arbitrary code execution.  Successful exploitation requires an attacker to get a user to open a specially crafted DSB file.  The vulnerability affects all versions of DASYLab."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-100",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-100 Overflow Buffers"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "LOCAL",
            "baseScore": 8.5,
            "baseSeverity": "HIGH",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "PASSIVE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1285",
              "description": "CWE-1285 Improper Validation of Specified Index, Position, or Offset in Input",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-09-03T16:14:10.432Z",
        "orgId": "bca5b2e8-03a4-4781-b4ca-c6a078c0bfd4",
        "shortName": "NI"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.ni.com/en/support/security/available-critical-and-security-updates-for-ni-software/memory-corruption-vulnerabilities-in-digilent-dasylab.html"
        },
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.measx.com/en/service/productsecurity/security-updates-for-measx-software/159-securityupdates/1077-deserialization-of-untrusted-data-vulnerability-in-dasylab.html"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Out Of Bounds Write when parsing a DSB file with Digilent DASYLab",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "bca5b2e8-03a4-4781-b4ca-c6a078c0bfd4",
    "assignerShortName": "NI",
    "cveId": "CVE-2025-9189",
    "datePublished": "2025-09-02T18:12:43.393Z",
    "dateReserved": "2025-08-19T16:51:08.483Z",
    "dateUpdated": "2026-09-03T16:14:10.432Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-7849 (GCVE-0-2025-7849)

Vulnerability from cvelistv5 – Published: 2025-07-29 21:27 – Updated: 2026-02-26 17:50
VLAI
Title
Memory Corruption Issue in NI LabVIEW due to improper error handling
Summary
A memory corruption vulnerability due to improper error handling when a VILinkObj is null exists in NI LabVIEW that may result in arbitrary code execution. Successful exploitation requires an attacker to get a user to open a specially crafted VI. This vulnerability affects NI LabVIEW 2025 Q1 and prior versions.
SSVC
Exploitation: none Automatable: no Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-08-02 03:55 UTC
CWE
Assigner
NI CNA under the mitre root
CNA scorecard B 84/100 over 28 records in the last 180 days details
Impacted products
Vendor Product Version
NI LabVIEW Affected: 0 , ≤ 22.3.5 (semver)
Affected: 23.0.0 , ≤ 23.3.6 (semver)
Affected: 24.0.0 , ≤ 24.3.3 (semver)
Affected: 25.0.0 , < 25.3.0 (semver)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-7849",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-08-02T03:55:49.567887Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-02-26T17:50:11.357Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "LabVIEW",
          "vendor": "NI",
          "versions": [
            {
              "lessThanOrEqual": "22.3.5",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            },
            {
              "lessThanOrEqual": "23.3.6",
              "status": "affected",
              "version": "23.0.0",
              "versionType": "semver"
            },
            {
              "lessThanOrEqual": "24.3.3",
              "status": "affected",
              "version": "24.0.0",
              "versionType": "semver"
            },
            {
              "lessThan": "25.3.0",
              "status": "affected",
              "version": "25.0.0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Rocco Calvi (@TecR0c) with TecSecurity working with Trend Micro Zero Day Initiative"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eA memory corruption vulnerability due to improper error handling when a VILinkObj is null exists in NI LabVIEW that may result in arbitrary code execution.  Successful exploitation requires an attacker to get a user to open a specially crafted VI.  This vulnerability affects NI LabVIEW 2025 Q1 and prior versions.\u003c/p\u003e"
            }
          ],
          "value": "A memory corruption vulnerability due to improper error handling when a VILinkObj is null exists in NI LabVIEW that may result in arbitrary code execution.  Successful exploitation requires an attacker to get a user to open a specially crafted VI.  This vulnerability affects NI LabVIEW 2025 Q1 and prior versions."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-23",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-23 File Content Injection"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "LOCAL",
            "baseScore": 8.5,
            "baseSeverity": "HIGH",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "PASSIVE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1285",
              "description": "CWE-1285",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-07-29T21:27:20.080Z",
        "orgId": "bca5b2e8-03a4-4781-b4ca-c6a078c0bfd4",
        "shortName": "NI"
      },
      "references": [
        {
          "url": "https://www.ni.com/en/support/security/available-critical-and-security-updates-for-ni-software/memory-corruption-vulnerabilities-in-ni-labview.html"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Memory Corruption Issue in NI LabVIEW due to improper error handling",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "bca5b2e8-03a4-4781-b4ca-c6a078c0bfd4",
    "assignerShortName": "NI",
    "cveId": "CVE-2025-7849",
    "datePublished": "2025-07-29T21:27:20.080Z",
    "dateReserved": "2025-07-18T21:43:09.001Z",
    "dateUpdated": "2026-02-26T17:50:11.357Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-7848 (GCVE-0-2025-7848)

Vulnerability from cvelistv5 – Published: 2025-07-29 21:24 – Updated: 2026-02-26 17:50
VLAI
Title
Missing input check in lvpict.cpp used in NI LabVIEW
Summary
A memory corruption vulnerability due to improper input validation in lvpict.cpp exists in NI LabVIEW that may result in arbitrary code execution. Successful exploitation requires an attacker to get a user to open a specially crafted VI. This vulnerability affects NI LabVIEW 2025 Q1 and prior versions.
SSVC
Exploitation: none Automatable: no Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-08-02 03:55 UTC
CWE
  • CWE-1285 - Improper Validation of Specified Index, Position, or Offset in Input
Assigner
NI CNA under the mitre root
CNA scorecard B 84/100 over 28 records in the last 180 days details
Impacted products
Vendor Product Version
NI LabVIEW Affected: 0 , ≤ 22.3.5 (semver)
Affected: 23.0.0 , ≤ 23.3.6 (semver)
Affected: 24.0.0 , ≤ 24.3.3 (semver)
Affected: 25.0.0 , < 25.3.0 (semver)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-7848",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-08-02T03:55:48.497075Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-02-26T17:50:11.817Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "LabVIEW",
          "vendor": "NI",
          "versions": [
            {
              "lessThanOrEqual": "22.3.5",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            },
            {
              "lessThanOrEqual": "23.3.6",
              "status": "affected",
              "version": "23.0.0",
              "versionType": "semver"
            },
            {
              "lessThanOrEqual": "24.3.3",
              "status": "affected",
              "version": "24.0.0",
              "versionType": "semver"
            },
            {
              "lessThan": "25.3.0",
              "status": "affected",
              "version": "25.0.0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Rocco Calvi (@TecR0c) with TecSecurity working with Trend Micro Zero Day Initiative"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eA memory corruption vulnerability due to improper input validation in lvpict.cpp exists in NI LabVIEW that may result in arbitrary code execution.  Successful exploitation requires an attacker to get a user to open a specially crafted VI.  This vulnerability affects NI LabVIEW 2025 Q1 and prior versions.\u003c/p\u003e"
            }
          ],
          "value": "A memory corruption vulnerability due to improper input validation in lvpict.cpp exists in NI LabVIEW that may result in arbitrary code execution.  Successful exploitation requires an attacker to get a user to open a specially crafted VI.  This vulnerability affects NI LabVIEW 2025 Q1 and prior versions."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-23",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-23 File Content Injection"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "LOCAL",
            "baseScore": 8.5,
            "baseSeverity": "HIGH",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "PASSIVE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1285",
              "description": "CWE-1285 Improper Validation of Specified Index, Position, or Offset in Input",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-07-29T21:24:32.568Z",
        "orgId": "bca5b2e8-03a4-4781-b4ca-c6a078c0bfd4",
        "shortName": "NI"
      },
      "references": [
        {
          "url": "https://www.ni.com/en/support/security/available-critical-and-security-updates-for-ni-software/memory-corruption-vulnerabilities-in-ni-labview.html"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Missing input check in lvpict.cpp used in NI LabVIEW",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "bca5b2e8-03a4-4781-b4ca-c6a078c0bfd4",
    "assignerShortName": "NI",
    "cveId": "CVE-2025-7848",
    "datePublished": "2025-07-29T21:24:32.568Z",
    "dateReserved": "2025-07-18T21:43:07.604Z",
    "dateUpdated": "2026-02-26T17:50:11.817Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-3755 (GCVE-0-2025-3755)

Vulnerability from cvelistv5 – Published: 2025-05-29 04:47 – Updated: 2025-08-27 08:02
VLAI
Title
Information Disclosure and Denial-of-Service(DoS) Vulnerability in MELSEC iQ-F Series CPU module
Summary
Improper Validation of Specified Index, Position, or Offset in Input vulnerability in Mitsubishi Electric Corporation MELSEC iQ-F Series CPU modules allows a remote unauthenticated attacker to read information in the product, to cause a Denial-of-Service (DoS) condition in MELSOFT connection, or to stop the operation of the CPU module (causing a DoS condtion on the CPU module), by sending specially crafted packets. The product is needed to reset for recovery.
SSVC
Exploitation: none Automatable: yes Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-05-29 13:16 UTC
CWE
  • CWE-1285 - Improper Validation of Specified Index, Position, or Offset in Input
Assigner
Mitsubishi CNA under the jpcert root
CNA scorecard – unranked: 8 records in the last 180 days, 10 needed details
References
Impacted products
Vendor Product Version
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5U-32MT/ES Affected: All versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5U-32MT/DS Affected: All versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5U-32MT/ESS Affected: All versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5U-32MT/DSS Affected: All versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5U-32MR/ES Affected: All versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5U-32MR/DS Affected: All versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5U-64MT/ES Affected: All versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5U-64MT/DS Affected: All versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5U-64MT/ESS Affected: All versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5U-64MT/DSS Affected: All versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5U-64MR/ES Affected: All versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5U-64MR/DS Affected: All versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5U-80MT/ES Affected: All versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5U-80MT/DS Affected: All versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5U-80MT/ESS Affected: All versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5U-80MT/DSS Affected: All versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5U-80MR/ES Affected: All versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5U-80MR/DS Affected: All versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UC-32MT/D Affected: All versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UC-32MT/DSS Affected: All versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UC-64MT/D Affected: All versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UC-64MT/DSS Affected: All versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UC-96MT/D Affected: All versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UC-96MT/DSS Affected: All versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UC-32MT/DS-TS Affected: All versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UC-32MT/DSS-TS Affected: All versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UC-32MR/DS-TS Affected: All versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UJ-24MT/ES Affected: All versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UJ-24MT/DS Affected: All versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UJ-24MT/ESS Affected: All versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UJ-24MT/DSS Affected: All versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UJ-24MR/ES Affected: All versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UJ-24MR/DS Affected: All versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UJ-40MT/ES Affected: All versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UJ-40MT/DS Affected: All versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UJ-40MT/ESS Affected: All versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UJ-40MT/DSS Affected: All versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UJ-40MR/ES Affected: All versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UJ-40MR/DS Affected: All versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UJ-60MT/ES Affected: All versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UJ-60MT/DS Affected: All versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UJ-60MT/ESS Affected: All versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UJ-60MT/DSS Affected: All versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UJ-60MR/ES Affected: All versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UJ-60MR/DS Affected: All versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UJ-24MT/ES-A Affected: All versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UJ-24MR/ES-A Affected: All versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UJ-40MT/ES-A Affected: All versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UJ-40MR/ES-A Affected: All versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UJ-60MT/ES-A Affected: All versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UJ-60MR/ES-A Affected: All versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5S-30MT/ES Affected: All versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5S-30MT/ESS Affected: All versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5S-30MR/ES Affected: All versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5S-40MT/ES Affected: All versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5S-40MT/ESS Affected: All versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5S-40MR/ES Affected: All versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5S-60MT/ES Affected: All versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5S-60MT/ESS Affected: All versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5S-60MR/ES Affected: All versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5S-80MT/ES Affected: All versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5S-80MT/ESS Affected: All versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5S-80MR/ES Affected: All versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5S-30MT/DS Affected: All versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5S-30MT/DSS Affected: All versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5S-30MR/DS Affected: All versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5S-40MT/DS Affected: All versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5S-40MT/DSS Affected: All versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5S-40MR/DS Affected: All versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5S-60MT/DS Affected: All versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5S-60MT/DSS Affected: All versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5S-60MR/DS Affected: All versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5S-80MT/DS Affected: All versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5S-80MT/DSS Affected: All versions
Create a notification for this product.
Mitsubishi Electric Corporation MELSEC iQ-F Series FX5S-80MR/DS Affected: All versions
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-3755",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-05-29T13:16:50.949939Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-05-29T13:17:00.867Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5U-32MT/ES",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5U-32MT/DS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5U-32MT/ESS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5U-32MT/DSS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5U-32MR/ES",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5U-32MR/DS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5U-64MT/ES",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5U-64MT/DS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5U-64MT/ESS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5U-64MT/DSS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5U-64MR/ES",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5U-64MR/DS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5U-80MT/ES",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5U-80MT/DS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5U-80MT/ESS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5U-80MT/DSS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5U-80MR/ES",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5U-80MR/DS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5UC-32MT/D",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5UC-32MT/DSS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5UC-64MT/D",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5UC-64MT/DSS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5UC-96MT/D",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5UC-96MT/DSS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5UC-32MT/DS-TS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5UC-32MT/DSS-TS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5UC-32MR/DS-TS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5UJ-24MT/ES",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5UJ-24MT/DS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5UJ-24MT/ESS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5UJ-24MT/DSS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5UJ-24MR/ES",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5UJ-24MR/DS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5UJ-40MT/ES",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5UJ-40MT/DS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5UJ-40MT/ESS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5UJ-40MT/DSS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5UJ-40MR/ES",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5UJ-40MR/DS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5UJ-60MT/ES",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5UJ-60MT/DS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5UJ-60MT/ESS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5UJ-60MT/DSS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5UJ-60MR/ES",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5UJ-60MR/DS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5UJ-24MT/ES-A",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5UJ-24MR/ES-A",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5UJ-40MT/ES-A",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5UJ-40MR/ES-A",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5UJ-60MT/ES-A",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5UJ-60MR/ES-A",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5S-30MT/ES",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5S-30MT/ESS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5S-30MR/ES",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5S-40MT/ES",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5S-40MT/ESS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5S-40MR/ES",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5S-60MT/ES",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5S-60MT/ESS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5S-60MR/ES",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5S-80MT/ES",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5S-80MT/ESS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5S-80MR/ES",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5S-30MT/DS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5S-30MT/DSS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5S-30MR/DS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5S-40MT/DS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5S-40MT/DSS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5S-40MR/DS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5S-60MT/DS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5S-60MT/DSS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5S-60MR/DS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5S-80MT/DS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5S-80MT/DSS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSEC iQ-F Series FX5S-80MR/DS",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Improper Validation of Specified Index, Position, or Offset in Input vulnerability in Mitsubishi Electric Corporation MELSEC iQ-F Series CPU modules allows a remote unauthenticated attacker to read information in the product, to cause a Denial-of-Service (DoS) condition in MELSOFT connection, or to stop the operation of the CPU module (causing a DoS condtion on the CPU module), by sending specially crafted packets. The product is needed to reset for recovery.\u003cbr\u003e"
            }
          ],
          "value": "Improper Validation of Specified Index, Position, or Offset in Input vulnerability in Mitsubishi Electric Corporation MELSEC iQ-F Series CPU modules allows a remote unauthenticated attacker to read information in the product, to cause a Denial-of-Service (DoS) condition in MELSOFT connection, or to stop the operation of the CPU module (causing a DoS condtion on the CPU module), by sending specially crafted packets. The product is needed to reset for recovery."
        }
      ],
      "impacts": [
        {
          "descriptions": [
            {
              "lang": "en",
              "value": "Denial-of-Service (DoS)"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.1,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1285",
              "description": "CWE-1285 Improper Validation of Specified Index, Position, or Offset in Input",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-08-27T08:02:37.808Z",
        "orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
        "shortName": "Mitsubishi"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2025-003_en.pdf"
        },
        {
          "tags": [
            "government-resource"
          ],
          "url": "https://jvn.jp/vu/JVNVU94070048/"
        },
        {
          "tags": [
            "government-resource"
          ],
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-153-03"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Information Disclosure and Denial-of-Service(DoS) Vulnerability in MELSEC iQ-F Series CPU module",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
    "assignerShortName": "Mitsubishi",
    "cveId": "CVE-2025-3755",
    "datePublished": "2025-05-29T04:47:52.187Z",
    "dateReserved": "2025-04-17T07:04:51.773Z",
    "dateUpdated": "2025-08-27T08:02:37.808Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2025-3357 (GCVE-0-2025-3357)

Vulnerability from cvelistv5 – Published: 2025-05-28 14:51 – Updated: 2026-02-26 18:27
VLAI
Title
IBM Tivoli Monitoring code execution
Summary
IBM Tivoli Monitoring 6.3.0.7 through 6.3.0.7 Service Pack 19 could allow a remote attacker to execute arbitrary code due to improper validation of an index value of a dynamically allocated array.
SSVC
Exploitation: none Automatable: yes Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-05-29 03:55 UTC
CWE
  • CWE-1285 - Improper Validation of Specified Index, Position, or Offset in Input
Assigner
ibm CNA under the mitre root
CNA scorecard B 88/100 over 1251 records in the last 180 days details
References
URL Tags
https://www.ibm.com/support/pages/node/7234923 vendor-advisorypatch
Impacted products
Vendor Product Version
IBM Tivoli Monitoring Affected: 6.3.0.7 , ≤ 6.3.0.7 SP15 (semver)
    cpe:2.3:a:ibm:tivoli_monitoring:6.3.0.7:*:*:*:*:*:*:*
    cpe:2.3:a:ibm:tivoli_monitoring:6.3.0.7:service_pack_15:*:*:*:*:*:*
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-3357",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-05-29T03:55:50.764227Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-02-26T18:27:50.921Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "cpes": [
            "cpe:2.3:a:ibm:tivoli_monitoring:6.3.0.7:*:*:*:*:*:*:*",
            "cpe:2.3:a:ibm:tivoli_monitoring:6.3.0.7:service_pack_15:*:*:*:*:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "Tivoli Monitoring",
          "vendor": "IBM",
          "versions": [
            {
              "lessThanOrEqual": "6.3.0.7 SP15",
              "status": "affected",
              "version": "6.3.0.7",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Aleksandr Tlyapov"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "IBM Tivoli Monitoring 6.3.0.7 through 6.3.0.7 Service Pack 19\u0026nbsp;could allow a remote attacker to execute arbitrary code due to improper validation of an index value of a dynamically allocated array."
            }
          ],
          "value": "IBM Tivoli Monitoring 6.3.0.7 through 6.3.0.7 Service Pack 19\u00a0could allow a remote attacker to execute arbitrary code due to improper validation of an index value of a dynamically allocated array."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1285",
              "description": "CWE-1285 Improper Validation of Specified Index, Position, or Offset in Input",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-08-26T14:56:28.301Z",
        "orgId": "9a959283-ebb5-44b6-b705-dcc2bbced522",
        "shortName": "ibm"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory",
            "patch"
          ],
          "url": "https://www.ibm.com/support/pages/node/7234923"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eIBM strongly recommends addressing the vulnerability now by upgrading to 6.3.0.7-SP0020\u003c/span\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "IBM strongly recommends addressing the vulnerability now by upgrading to 6.3.0.7-SP0020"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "IBM Tivoli Monitoring code execution",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "9a959283-ebb5-44b6-b705-dcc2bbced522",
    "assignerShortName": "ibm",
    "cveId": "CVE-2025-3357",
    "datePublished": "2025-05-28T14:51:29.649Z",
    "dateReserved": "2025-04-06T21:14:20.726Z",
    "dateUpdated": "2026-02-26T18:27:50.921Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

Mitigation MIT-5
Implementation

Strategy: Input Validation

  • Assume all input is malicious. Use an "accept known good" input validation strategy, i.e., use a list of acceptable inputs that strictly conform to specifications. Reject any input that does not strictly conform to specifications, or transform it into something that does.
  • When performing input validation, consider all potentially relevant properties, including length, type of input, the full range of acceptable values, missing or extra inputs, syntax, consistency across related fields, and conformance to business rules. As an example of business rule logic, "boat" may be syntactically valid because it only contains alphanumeric characters, but it is not valid if the input is only expected to contain colors such as "red" or "blue."
  • Do not rely exclusively on looking for malicious or malformed inputs. This is likely to miss at least one undesirable input, especially if the code's environment changes. This can give attackers enough room to bypass the intended validation. However, denylists can be useful for detecting potential attacks or determining which inputs are so malformed that they should be rejected outright.

No CAPEC attack patterns related to this CWE.