Common Weakness Enumeration

CWE-121

Allowed

Stack-based Buffer Overflow

Abstraction: Variant · Status: Draft

A stack-based buffer overflow condition is a condition where the buffer being overwritten is allocated on the stack (i.e., is a local variable or, rarely, a parameter to a function).

5245 vulnerabilities reference this CWE, most recent first.

CVE-2014-9190 (GCVE-0-2014-9190)

Vulnerability from cvelistv5 – Published: 2015-01-10 02:00 – Updated: 2025-07-24 22:42
VLAI
Title
Schneider Electric Wonderware InTouch Access Anywhere Server Buffer Overflow
Summary
Stack-based buffer overflow in Schneider Electric Wonderware InTouch Access Anywhere Server 10.6 and 11.0 allows remote attackers to execute arbitrary code via a request for a filename that does not exist.
Severity
No CVSS data available.
CWE
Assigner
Impacted products
Date Public
2015-01-08 07:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T13:40:24.643Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://wdnresource.wonderware.com/support/docs/_SecurityBulletins/Security_Bulletin_LFSEC00000104.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-008-02"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "InTouch Access Anywhere Server",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "10.6"
            },
            {
              "status": "affected",
              "version": "11.0"
            }
          ]
        }
      ],
      "datePublic": "2015-01-08T07:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eStack-based buffer overflow in Schneider Electric Wonderware InTouch Access Anywhere Server 10.6 and 11.0 allows remote attackers to execute arbitrary code via a request for a filename that does not exist.\u003c/p\u003e"
            }
          ],
          "value": "Stack-based buffer overflow in Schneider Electric Wonderware InTouch Access Anywhere Server 10.6 and 11.0 allows remote attackers to execute arbitrary code via a request for a filename that does not exist."
        }
      ],
      "metrics": [
        {
          "cvssV2_0": {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10,
            "confidentialityImpact": "COMPLETE",
            "integrityImpact": "COMPLETE",
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-07-24T22:42:57.203Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://wdnresource.wonderware.com/support/docs/_SecurityBulletins/Security_Bulletin_LFSEC00000104.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-15-008-02"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eSchneider Electric has released a security update that mitigates the \nstack-based buffer overflow vulnerability in Wonderware\u2019s InTouch Access\n Anywhere Server product, Versions 10.6 and 11.0. Schneider Electric\u2019s \nsecurity updates for Version 10.6 and Version 11.0 are available at the \nfollowing location with a user account:\u003c/p\u003e\n\u003cp\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://wdnresource.wonderware.com/tracking/confirmdownload.aspx?id=3001\u0026amp;url=https://wdnresource.wonderware.com/support/patchfixes/1/WW-ITAA2014P01-LFSEC104.zip\u0026amp;rme=https://wdnresource.wonderware.com/support/patchfixes/1/WW-ITAA2014P01-LFSEC104.txt\"\u003ehttps://wdnresource.wonderware.com/tracking/confirmdownload.aspx?id=3001\u0026amp;url=https://wdnresource...\u003c/a\u003e\u003c/p\u003e\n\u003cp\u003eSchneider Electric has released a security bulletin titled \u201cInTouch \nAccess Anywhere Server Security Vulnerability, LFSEC00000104\u201d to \nannounce the security update, which is available at the following \nlocation:\u003c/p\u003e\n\u003cp\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://gcsresource.invensys.com/support/docs/_SecurityBulletins/Security_Bulletin_LFSEC00000104.pdf\"\u003ehttps://gcsresource.invensys.com/support/docs/_SecurityBulletins/Security_Bulletin_LFSEC00000104.pdf\u003c/a\u003e\u003c/p\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "Schneider Electric has released a security update that mitigates the \nstack-based buffer overflow vulnerability in Wonderware\u2019s InTouch Access\n Anywhere Server product, Versions 10.6 and 11.0. Schneider Electric\u2019s \nsecurity updates for Version 10.6 and Version 11.0 are available at the \nfollowing location with a user account:\n\n\n https://wdnresource.wonderware.com/tracking/confirmdownload.aspx?id=3001\u0026url=https://wdnresource... https://wdnresource.wonderware.com/tracking/confirmdownload.aspx \n\n\nSchneider Electric has released a security bulletin titled \u201cInTouch \nAccess Anywhere Server Security Vulnerability, LFSEC00000104\u201d to \nannounce the security update, which is available at the following \nlocation:\n\n\n https://gcsresource.invensys.com/support/docs/_SecurityBulletins/Security_Bulletin_LFSEC00000104.pdf"
        }
      ],
      "source": {
        "advisory": "ICSA-15-008-02",
        "discovery": "INTERNAL"
      },
      "title": "Schneider Electric Wonderware InTouch Access Anywhere Server Buffer Overflow",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2014-9190",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Stack-based buffer overflow in Schneider Electric Wonderware InTouch Access Anywhere Server 10.6 and 11.0 allows remote attackers to execute arbitrary code via a request for a filename that does not exist."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://wdnresource.wonderware.com/support/docs/_SecurityBulletins/Security_Bulletin_LFSEC00000104.pdf",
              "refsource": "CONFIRM",
              "url": "https://wdnresource.wonderware.com/support/docs/_SecurityBulletins/Security_Bulletin_LFSEC00000104.pdf"
            },
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-15-008-02",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-008-02"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2014-9190",
    "datePublished": "2015-01-10T02:00:00.000Z",
    "dateReserved": "2014-12-02T00:00:00.000Z",
    "dateUpdated": "2025-07-24T22:42:57.203Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2014-9189 (GCVE-0-2014-9189)

Vulnerability from cvelistv5 – Published: 2019-03-25 19:10 – Updated: 2024-08-06 13:40
VLAI
Summary
Multiple stack-based buffer overflow vulnerabilities were found in Honeywell Experion PKS all versions prior to R400.6, all versions prior to R410.6, and all versions prior to R430.2 modules that could lead to possible remote code execution, dynamic memory corruption, or denial of service. Honeywell strongly encourages and recommends all customers running unsupported versions of EKPS prior to R400 to upgrade to a supported version.
Severity
No CVSS data available.
CWE
  • CWE-121 - Stack-based buffer overflow CWE-121
Assigner
References
Impacted products
Vendor Product Version
Honeywell Experion PKS Affected: R40x prior to R400.6
Affected: R41x prior to R410.6
Affected: R43x prior to R430.2
Create a notification for this product.
Date Public
2014-12-18 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T13:40:23.163Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-14-352-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Experion PKS",
          "vendor": "Honeywell",
          "versions": [
            {
              "status": "affected",
              "version": "R40x prior to R400.6"
            },
            {
              "status": "affected",
              "version": "R41x prior to R410.6"
            },
            {
              "status": "affected",
              "version": "R43x prior to R430.2"
            }
          ]
        }
      ],
      "datePublic": "2014-12-18T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "Multiple stack-based buffer overflow vulnerabilities were found in Honeywell Experion PKS all versions prior to R400.6, all versions prior to R410.6, and all versions prior to R430.2 modules that could lead to possible remote code execution, dynamic memory corruption, or denial of service. Honeywell strongly encourages and recommends all customers running unsupported versions of EKPS prior to R400 to upgrade to a supported version."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "Stack-based buffer overflow CWE-121",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-03-25T19:10:47.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-14-352-01"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2014-9189",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Experion PKS",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "R40x prior to R400.6"
                          },
                          {
                            "version_value": "R41x prior to R410.6"
                          },
                          {
                            "version_value": "R43x prior to R430.2"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Honeywell"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Multiple stack-based buffer overflow vulnerabilities were found in Honeywell Experion PKS all versions prior to R400.6, all versions prior to R410.6, and all versions prior to R430.2 modules that could lead to possible remote code execution, dynamic memory corruption, or denial of service. Honeywell strongly encourages and recommends all customers running unsupported versions of EKPS prior to R400 to upgrade to a supported version."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Stack-based buffer overflow CWE-121"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-14-352-01",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-14-352-01"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2014-9189",
    "datePublished": "2019-03-25T19:10:47.000Z",
    "dateReserved": "2014-12-02T00:00:00.000Z",
    "dateUpdated": "2024-08-06T13:40:23.163Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2014-8184 (GCVE-0-2014-8184)

Vulnerability from cvelistv5 – Published: 2019-08-02 12:00 – Updated: 2024-08-06 13:10
VLAI
Summary
A vulnerability was found in liblouis, versions 2.5.x before 2.5.4. A stack-based buffer overflow was found in findTable() in liblouis. An attacker could create a malicious file that would cause applications that use liblouis (such as Orca) to crash, or potentially execute arbitrary code when opened.
CWE
Assigner
References
Impacted products
Vendor Product Version
Liblouis liblouis Affected: 2.5.x before 2.5.4
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T13:10:50.898Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/liblouis/liblouis/issues/425"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://bugzilla.redhat.com/show_bug.cgi?id=CVE-2014-8184"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "liblouis",
          "vendor": "Liblouis",
          "versions": [
            {
              "status": "affected",
              "version": "2.5.x before 2.5.4"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in liblouis, versions 2.5.x before 2.5.4. A stack-based buffer overflow was found in findTable() in liblouis. An attacker could create a malicious file that would cause applications that use liblouis (such as Orca) to crash, or potentially execute arbitrary code when opened."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-08-02T12:00:37.000Z",
        "orgId": "53f830b8-0a3f-465b-8143-3b8a9948e749",
        "shortName": "redhat"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/liblouis/liblouis/issues/425"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://bugzilla.redhat.com/show_bug.cgi?id=CVE-2014-8184"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "53f830b8-0a3f-465b-8143-3b8a9948e749",
    "assignerShortName": "redhat",
    "cveId": "CVE-2014-8184",
    "datePublished": "2019-08-02T12:00:37.000Z",
    "dateReserved": "2014-10-10T00:00:00.000Z",
    "dateUpdated": "2024-08-06T13:10:50.898Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2014-5407 (GCVE-0-2014-5407)

Vulnerability from cvelistv5 – Published: 2014-09-15 14:00 – Updated: 2025-11-03 18:52
VLAI
Title
Schneider Electric VAMPSET Stack-based Buffer Overflow
Summary
Multiple stack-based buffer overflows in Schneider Electric VAMPSET 2.2.136 and earlier allow local users to cause a denial of service (application halt) via a malformed (1) setting file or (2) disturbance recording file.
Severity
No CVSS data available.
CWE
Assigner
Impacted products
Vendor Product Version
Schneider Electric VAMPSET Affected: 0 , ≤ 2.2.136 (custom)
Unaffected: 2.2.145
Create a notification for this product.
Date Public
2014-09-11 06:00
Credits
Aivar Liimets of Martem AS
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T11:41:49.181Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-14-254-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "VAMPSET",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "lessThanOrEqual": "2.2.136",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            },
            {
              "status": "unaffected",
              "version": "2.2.145"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Aivar Liimets of Martem AS"
        }
      ],
      "datePublic": "2014-09-11T06:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eMultiple stack-based buffer overflows in Schneider Electric VAMPSET 2.2.136 and earlier allow local users to cause a denial of service (application halt) via a malformed (1) setting file or (2) disturbance recording file.\u003c/p\u003e"
            }
          ],
          "value": "Multiple stack-based buffer overflows in Schneider Electric VAMPSET 2.2.136 and earlier allow local users to cause a denial of service (application halt) via a malformed (1) setting file or (2) disturbance recording file."
        }
      ],
      "metrics": [
        {
          "cvssV2_0": {
            "accessComplexity": "MEDIUM",
            "accessVector": "LOCAL",
            "authentication": "SINGLE",
            "availabilityImpact": "PARTIAL",
            "baseScore": 4.1,
            "confidentialityImpact": "PARTIAL",
            "integrityImpact": "PARTIAL",
            "vectorString": "AV:L/AC:M/Au:S/C:P/I:P/A:P",
            "version": "2.0"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-11-03T18:52:21.206Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-14-254-01"
        },
        {
          "url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2014/icsa-14-254-01.json"
        },
        {
          "url": "http://www.schneider-electric.com/products/ww/en/2300-ied-user-software/2320-vamp-user-software/62050-vamp-software/"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eSchneider Electric released an update for distribution on August 21, \n2014. The VAMPSET setting tool, v.2.2.145 or newer, can be found here:\u003c/p\u003e\n\u003cp\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"http://www.schneider-electric.com/products/ww/en/2300-ied-user-software/2320-vamp-user-software/62050-vamp-software/\"\u003ehttp://www.schneider-electric.com/products/ww/en/2300-ied-user-software/2320-vamp-user-software/62050-vamp-software/\u003c/a\u003e\u003c/p\u003eSchneider Electric recommends that all customers and users install and use VAMPSET v.2.2.145 or newer.\n\n\u003cbr\u003e"
            }
          ],
          "value": "Schneider Electric released an update for distribution on August 21, \n2014. The VAMPSET setting tool, v.2.2.145 or newer, can be found here:\n\n\n http://www.schneider-electric.com/products/ww/en/2300-ied-user-software/2320-vamp-user-software/62050-vamp-software/ \n\nSchneider Electric recommends that all customers and users install and use VAMPSET v.2.2.145 or newer."
        }
      ],
      "source": {
        "advisory": "ICSA-14-254-01",
        "discovery": "EXTERNAL"
      },
      "title": "Schneider Electric VAMPSET Stack-based Buffer Overflow",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "To protect the computer and configuration files from unauthorized \nescalation of privileges through manipulation, Schneider Electric \nrecommends users employ best IT practices to secure their computers and \nrelay\u2019s configuration files and to use User Access Control (UAC) to \nfurther improve the security of the computer. Additionally, to minimize \nthe risk of attack, users who are not directly using this software on a \nregular basis are strongly encouraged to delete this application from \ntheir computer to reduce the likelihood of attack and to store relay \nconfiguration files in the client\u2019s protected location.\n\n\u003cbr\u003e"
            }
          ],
          "value": "To protect the computer and configuration files from unauthorized \nescalation of privileges through manipulation, Schneider Electric \nrecommends users employ best IT practices to secure their computers and \nrelay\u2019s configuration files and to use User Access Control (UAC) to \nfurther improve the security of the computer. Additionally, to minimize \nthe risk of attack, users who are not directly using this software on a \nregular basis are strongly encouraged to delete this application from \ntheir computer to reduce the likelihood of attack and to store relay \nconfiguration files in the client\u2019s protected location."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.5.0"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2014-5407",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Multiple stack-based buffer overflows in Schneider Electric VAMPSET 2.2.136 and earlier allow local users to cause a denial of service (application halt) via a malformed (1) setting file or (2) disturbance recording file."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-14-254-01",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-14-254-01"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2014-5407",
    "datePublished": "2014-09-15T14:00:00.000Z",
    "dateReserved": "2014-08-22T00:00:00.000Z",
    "dateUpdated": "2025-11-03T18:52:21.206Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2014-2364 (GCVE-0-2014-2364)

Vulnerability from cvelistv5 – Published: 2014-07-19 01:00 – Updated: 2025-10-06 17:52
VLAI
Title
Advantech WebAccess Stack-Based Buffer Overflow
Summary
Multiple stack-based buffer overflows in Advantech WebAccess before 7.2 allow remote attackers to execute arbitrary code via a long string in the (1) ProjectName, (2) SetParameter, (3) NodeName, (4) CCDParameter, (5) SetColor, (6) AlarmImage, (7) GetParameter, (8) GetColor, (9) ServerResponse, (10) SetBaud, or (11) IPAddress parameter to an ActiveX control in (a) webvact.ocx, (b) dvs.ocx, or (c) webdact.ocx.
Severity
No CVSS data available.
CWE
Assigner
Impacted products
Vendor Product Version
Advantech WebAccess Affected: 0 , ≤ 7.1 (custom)
Unaffected: 7.2
Create a notification for this product.
Date Public
2014-07-15 06:00
Credits
reported to ZDI by security researchers Dave Weinstein, Tom Gallagher, John Leitch, and others
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T10:14:25.490Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-198-02"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://packetstormsecurity.com/files/128384/Advantech-WebAccess-dvs.ocx-GetColor-Buffer-Overflow.html"
          },
          {
            "name": "68714",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/68714"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "WebAccess",
          "vendor": "Advantech",
          "versions": [
            {
              "lessThanOrEqual": "7.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            },
            {
              "status": "unaffected",
              "version": "7.2"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "reported to ZDI by security researchers Dave Weinstein, Tom Gallagher, John Leitch, and others"
        }
      ],
      "datePublic": "2014-07-15T06:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eMultiple stack-based buffer overflows in Advantech WebAccess before 7.2 allow remote attackers to execute arbitrary code via a long string in the (1) ProjectName, (2) SetParameter, (3) NodeName, (4) CCDParameter, (5) SetColor, (6) AlarmImage, (7) GetParameter, (8) GetColor, (9) ServerResponse, (10) SetBaud, or (11) IPAddress parameter to an ActiveX control in (a) webvact.ocx, (b) dvs.ocx, or (c) webdact.ocx.\u003c/p\u003e"
            }
          ],
          "value": "Multiple stack-based buffer overflows in Advantech WebAccess before 7.2 allow remote attackers to execute arbitrary code via a long string in the (1) ProjectName, (2) SetParameter, (3) NodeName, (4) CCDParameter, (5) SetColor, (6) AlarmImage, (7) GetParameter, (8) GetColor, (9) ServerResponse, (10) SetBaud, or (11) IPAddress parameter to an ActiveX control in (a) webvact.ocx, (b) dvs.ocx, or (c) webdact.ocx."
        }
      ],
      "metrics": [
        {
          "cvssV2_0": {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "integrityImpact": "PARTIAL",
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-10-06T17:52:36.174Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-14-198-02"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://packetstormsecurity.com/files/128384/Advantech-WebAccess-dvs.ocx-GetColor-Buffer-Overflow.html"
        },
        {
          "name": "68714",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/68714"
        },
        {
          "url": "http://webaccess.advantech.com/"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eAdvantech released a new WebAccess Installation Package v7.2 on June \n6, 2014, that removes some vulnerable ActiveX components and resolves \nthe vulnerabilities within others. The download link for v7.2 is \navailable at:\u003c/p\u003e\n\u003cp\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"http://webaccess.advantech.com/\"\u003ehttp://webaccess.advantech.com/\u003c/a\u003e\u003c/p\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "Advantech released a new WebAccess Installation Package v7.2 on June \n6, 2014, that removes some vulnerable ActiveX components and resolves \nthe vulnerabilities within others. The download link for v7.2 is \navailable at:\n\n\n http://webaccess.advantech.com/"
        }
      ],
      "source": {
        "advisory": "ICSA-14-198-02",
        "discovery": "EXTERNAL"
      },
      "title": "Advantech WebAccess Stack-Based Buffer Overflow",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2014-2364",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Multiple stack-based buffer overflows in Advantech WebAccess before 7.2 allow remote attackers to execute arbitrary code via a long string in the (1) ProjectName, (2) SetParameter, (3) NodeName, (4) CCDParameter, (5) SetColor, (6) AlarmImage, (7) GetParameter, (8) GetColor, (9) ServerResponse, (10) SetBaud, or (11) IPAddress parameter to an ActiveX control in (a) webvact.ocx, (b) dvs.ocx, or (c) webdact.ocx."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://ics-cert.us-cert.gov/advisories/ICSA-14-198-02",
              "refsource": "MISC",
              "url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-198-02"
            },
            {
              "name": "http://packetstormsecurity.com/files/128384/Advantech-WebAccess-dvs.ocx-GetColor-Buffer-Overflow.html",
              "refsource": "MISC",
              "url": "http://packetstormsecurity.com/files/128384/Advantech-WebAccess-dvs.ocx-GetColor-Buffer-Overflow.html"
            },
            {
              "name": "68714",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/68714"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2014-2364",
    "datePublished": "2014-07-19T01:00:00.000Z",
    "dateReserved": "2014-03-13T00:00:00.000Z",
    "dateUpdated": "2025-10-06T17:52:36.174Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2014-0787 (GCVE-0-2014-0787)

Vulnerability from cvelistv5 – Published: 2014-04-12 01:00 – Updated: 2025-09-25 17:39
VLAI
Title
WellinTech KingSCADA Stack-based Buffer Overflow
Summary
Stack-based buffer overflow in WellinTech KingSCADA before 3.1.2.13 allows remote attackers to execute arbitrary code via a crafted packet.
Severity
No CVSS data available.
CWE
Assigner
Impacted products
Vendor Product Version
WellinTech KingSCADA Affected: 0 , < v3.1.2.13 (custom)
Create a notification for this product.
Date Public
2014-04-08 06:00
Credits
HP’s Zero Day Initiative
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T09:27:19.475Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-098-02"
          },
          {
            "name": "42724",
            "tags": [
              "exploit",
              "x_refsource_EXPLOIT-DB",
              "x_transferred"
            ],
            "url": "https://www.exploit-db.com/exploits/42724/"
          },
          {
            "name": "66709",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/66709"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "KingSCADA",
          "vendor": "WellinTech",
          "versions": [
            {
              "lessThan": "v3.1.2.13",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "HP\u2019s Zero Day Initiative"
        }
      ],
      "datePublic": "2014-04-08T06:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eStack-based buffer overflow in WellinTech KingSCADA before 3.1.2.13 allows remote attackers to execute arbitrary code via a crafted packet.\u003c/p\u003e"
            }
          ],
          "value": "Stack-based buffer overflow in WellinTech KingSCADA before 3.1.2.13 allows remote attackers to execute arbitrary code via a crafted packet."
        }
      ],
      "metrics": [
        {
          "cvssV2_0": {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "availabilityImpact": "COMPLETE",
            "baseScore": 10,
            "confidentialityImpact": "COMPLETE",
            "integrityImpact": "COMPLETE",
            "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-09-25T17:39:03.344Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-14-098-02"
        },
        {
          "name": "42724",
          "tags": [
            "exploit",
            "x_refsource_EXPLOIT-DB"
          ],
          "url": "https://www.exploit-db.com/exploits/42724/"
        },
        {
          "name": "66709",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/66709"
        },
        {
          "url": "http://www.wellintech.com/index.php?option=com_content\u0026view=article\u0026id=56\u0026Itemid=11"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eWellinTech has created a patch and instructions for installation that are available for download on its web site at:\u003c/p\u003e\u003cp\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"http://www.wellintech.com/index.php?option=com_content\u0026amp;view=article\u0026amp;id=56\u0026amp;Itemid=11\"\u003ehttp://www.wellintech.com/index.php?option=com_content\u0026amp;view=article\u0026amp;id=56\u0026amp;Itemid=11\u003c/a\u003e\u003c/p\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "WellinTech has created a patch and instructions for installation that are available for download on its web site at:\n\n http://www.wellintech.com/index.php?option=com_content\u0026view=article\u0026id=56\u0026Itemid=11"
        }
      ],
      "source": {
        "advisory": "ICSA-14-098-02",
        "discovery": "EXTERNAL"
      },
      "title": "WellinTech KingSCADA Stack-based Buffer Overflow",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2014-0787",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Stack-based buffer overflow in WellinTech KingSCADA before 3.1.2.13 allows remote attackers to execute arbitrary code via a crafted packet."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://ics-cert.us-cert.gov/advisories/ICSA-14-098-02",
              "refsource": "MISC",
              "url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-098-02"
            },
            {
              "name": "42724",
              "refsource": "EXPLOIT-DB",
              "url": "https://www.exploit-db.com/exploits/42724/"
            },
            {
              "name": "66709",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/66709"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2014-0787",
    "datePublished": "2014-04-12T01:00:00.000Z",
    "dateReserved": "2014-01-02T00:00:00.000Z",
    "dateUpdated": "2025-09-25T17:39:03.344Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2014-0784 (GCVE-0-2014-0784)

Vulnerability from cvelistv5 – Published: 2014-03-14 10:00 – Updated: 2025-09-25 17:25
VLAI
Title
Yokogawa CENTUM CS 3000 Stack-based Buffer Overflow
Summary
Stack-based buffer overflow in BKBCopyD.exe in Yokogawa CENTUM CS 3000 R3.09.50 and earlier allows remote attackers to execute arbitrary code via a crafted TCP packet.
Severity
No CVSS data available.
CWE
Assigner
Impacted products
Vendor Product Version
Yokogawa CENTUM CS 3000 Affected: 0 , < R3.09.50 (custom)
Create a notification for this product.
Date Public
2014-03-11 06:00
Credits
Juan Vazquez of Rapid7 Inc.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T09:27:19.533Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-070-01"
          },
          {
            "name": "66114",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/66114"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://community.rapid7.com/community/metasploit/blog/2014/03/10/yokogawa-centum-cs3000-vulnerabilities"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "CENTUM CS 3000",
          "vendor": "Yokogawa",
          "versions": [
            {
              "lessThan": "R3.09.50",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Juan Vazquez of Rapid7 Inc."
        }
      ],
      "datePublic": "2014-03-11T06:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003e\n\nStack-based buffer overflow in BKBCopyD.exe in Yokogawa CENTUM CS 3000 R3.09.50 and earlier allows remote attackers to execute arbitrary code via a crafted TCP packet.\n\n\u003c/p\u003e"
            }
          ],
          "value": "Stack-based buffer overflow in BKBCopyD.exe in Yokogawa CENTUM CS 3000 R3.09.50 and earlier allows remote attackers to execute arbitrary code via a crafted TCP packet."
        }
      ],
      "metrics": [
        {
          "cvssV2_0": {
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "availabilityImpact": "COMPLETE",
            "baseScore": 8.3,
            "confidentialityImpact": "PARTIAL",
            "integrityImpact": "PARTIAL",
            "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:C",
            "version": "2.0"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-09-25T17:25:47.981Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-14-070-01a"
        },
        {
          "name": "66130",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/66130"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://community.rapid7.com/community/metasploit/blog/2014/03/10/yokogawa-centum-cs3000-vulnerabilities"
        },
        {
          "url": "http://www.yokogawa.com/dcs/security/ysar/dcs-ysar-index-en.htm."
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eYokogawa has created a patch (CENTUM CS 3000 R3.09.73 and R3.09.75) to mitigate the reported vulnerabilities. To activate the patch software, the computer needs to be rebooted. Older versions of the CENTUM CS 3000 will need to be updated to the latest version of R3.09.50 before installing the patch software.\u003cbr\u003e\u003c/p\u003e\u003cp\u003eYokogawa also suggests all customers introduce appropriate security measures to the overall system, not just for the vulnerabilities identified.\u003c/p\u003e\u003cp\u003eFor more information, please see the advisory that Yokogawa has published regarding this issue here: \u003ca target=\"_blank\" rel=\"nofollow\" href=\"http://www.yokogawa.com/dcs/security/ysar/dcs-ysar-index-en.htm\"\u003ehttp://www.yokogawa.com/dcs/security/ysar/dcs-ysar-index-en.htm\u003c/a\u003e.\u003c/p\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "Yokogawa has created a patch (CENTUM CS 3000 R3.09.73 and R3.09.75) to mitigate the reported vulnerabilities. To activate the patch software, the computer needs to be rebooted. Older versions of the CENTUM CS 3000 will need to be updated to the latest version of R3.09.50 before installing the patch software.\n\n\nYokogawa also suggests all customers introduce appropriate security measures to the overall system, not just for the vulnerabilities identified.\n\nFor more information, please see the advisory that Yokogawa has published regarding this issue here:  http://www.yokogawa.com/dcs/security/ysar/dcs-ysar-index-en.htm ."
        }
      ],
      "source": {
        "advisory": "ICSA-14-070-01",
        "discovery": "EXTERNAL"
      },
      "title": "Yokogawa CENTUM CS 3000 Stack-based Buffer Overflow",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2014-0781",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Heap-based buffer overflow in BKCLogSvr.exe in Yokogawa CENTUM CS 3000 R3.09.50 and earlier allows remote attackers to execute arbitrary code via crafted UDP packets."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://ics-cert.us-cert.gov/advisories/ICSA-14-070-01",
              "refsource": "MISC",
              "url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-070-01"
            },
            {
              "name": "66130",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/66130"
            },
            {
              "name": "https://community.rapid7.com/community/metasploit/blog/2014/03/10/yokogawa-centum-cs3000-vulnerabilities",
              "refsource": "MISC",
              "url": "https://community.rapid7.com/community/metasploit/blog/2014/03/10/yokogawa-centum-cs3000-vulnerabilities"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2014-0784",
    "datePublished": "2014-03-14T10:00:00.000Z",
    "dateReserved": "2014-01-02T00:00:00.000Z",
    "dateUpdated": "2025-09-25T17:25:47.981Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2014-0783 (GCVE-0-2014-0783)

Vulnerability from cvelistv5 – Published: 2014-03-14 10:00 – Updated: 2025-09-25 17:24
VLAI
Title
Yokogawa CENTUM CS 3000 Stack-based Buffer Overflow
Summary
Stack-based buffer overflow in BKHOdeq.exe in Yokogawa CENTUM CS 3000 R3.09.50 and earlier allows remote attackers to execute arbitrary code via a crafted TCP packet.
Severity
No CVSS data available.
CWE
Assigner
Impacted products
Vendor Product Version
Yokogawa CENTUM CS 3000 Affected: 0 , < R3.09.50 (custom)
Create a notification for this product.
Date Public
2014-03-11 06:00
Credits
Juan Vazquez of Rapid7 Inc.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T09:27:19.511Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-070-01"
          },
          {
            "name": "66111",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/66111"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://community.rapid7.com/community/metasploit/blog/2014/03/10/yokogawa-centum-cs3000-vulnerabilities"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "CENTUM CS 3000",
          "vendor": "Yokogawa",
          "versions": [
            {
              "lessThan": "R3.09.50",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Juan Vazquez of Rapid7 Inc."
        }
      ],
      "datePublic": "2014-03-11T06:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003e\nStack-based buffer overflow in BKHOdeq.exe in Yokogawa CENTUM CS 3000 R3.09.50 and earlier allows remote attackers to execute arbitrary code via a crafted TCP packet.\n\n\u003c/p\u003e"
            }
          ],
          "value": "Stack-based buffer overflow in BKHOdeq.exe in Yokogawa CENTUM CS 3000 R3.09.50 and earlier allows remote attackers to execute arbitrary code via a crafted TCP packet."
        }
      ],
      "metrics": [
        {
          "cvssV2_0": {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "availabilityImpact": "COMPLETE",
            "baseScore": 9,
            "confidentialityImpact": "PARTIAL",
            "integrityImpact": "PARTIAL",
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:C",
            "version": "2.0"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-09-25T17:24:25.563Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-14-070-01a"
        },
        {
          "name": "66130",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/66130"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://community.rapid7.com/community/metasploit/blog/2014/03/10/yokogawa-centum-cs3000-vulnerabilities"
        },
        {
          "url": "http://www.yokogawa.com/dcs/security/ysar/dcs-ysar-index-en.htm."
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eYokogawa has created a patch (CENTUM CS 3000 R3.09.73 and R3.09.75) to mitigate the reported vulnerabilities. To activate the patch software, the computer needs to be rebooted. Older versions of the CENTUM CS 3000 will need to be updated to the latest version of R3.09.50 before installing the patch software.\u003cbr\u003e\u003c/p\u003e\u003cp\u003eYokogawa also suggests all customers introduce appropriate security measures to the overall system, not just for the vulnerabilities identified.\u003c/p\u003e\u003cp\u003eFor more information, please see the advisory that Yokogawa has published regarding this issue here: \u003ca target=\"_blank\" rel=\"nofollow\" href=\"http://www.yokogawa.com/dcs/security/ysar/dcs-ysar-index-en.htm\"\u003ehttp://www.yokogawa.com/dcs/security/ysar/dcs-ysar-index-en.htm\u003c/a\u003e.\u003c/p\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "Yokogawa has created a patch (CENTUM CS 3000 R3.09.73 and R3.09.75) to mitigate the reported vulnerabilities. To activate the patch software, the computer needs to be rebooted. Older versions of the CENTUM CS 3000 will need to be updated to the latest version of R3.09.50 before installing the patch software.\n\n\nYokogawa also suggests all customers introduce appropriate security measures to the overall system, not just for the vulnerabilities identified.\n\nFor more information, please see the advisory that Yokogawa has published regarding this issue here:  http://www.yokogawa.com/dcs/security/ysar/dcs-ysar-index-en.htm ."
        }
      ],
      "source": {
        "advisory": "ICSA-14-070-01",
        "discovery": "EXTERNAL"
      },
      "title": "Yokogawa CENTUM CS 3000 Stack-based Buffer Overflow",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2014-0781",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Heap-based buffer overflow in BKCLogSvr.exe in Yokogawa CENTUM CS 3000 R3.09.50 and earlier allows remote attackers to execute arbitrary code via crafted UDP packets."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://ics-cert.us-cert.gov/advisories/ICSA-14-070-01",
              "refsource": "MISC",
              "url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-070-01"
            },
            {
              "name": "66130",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/66130"
            },
            {
              "name": "https://community.rapid7.com/community/metasploit/blog/2014/03/10/yokogawa-centum-cs3000-vulnerabilities",
              "refsource": "MISC",
              "url": "https://community.rapid7.com/community/metasploit/blog/2014/03/10/yokogawa-centum-cs3000-vulnerabilities"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2014-0783",
    "datePublished": "2014-03-14T10:00:00.000Z",
    "dateReserved": "2014-01-02T00:00:00.000Z",
    "dateUpdated": "2025-09-25T17:24:25.563Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2014-0782 (GCVE-0-2014-0782)

Vulnerability from cvelistv5 – Published: 2014-05-16 10:00 – Updated: 2025-09-25 17:27
VLAI
Title
Yokogawa CENTUM CS 3000 Stack-based Buffer Overflow
Summary
Stack-based buffer overflow in BKESimmgr.exe in the Expanded Test Functions package in Yokogawa CENTUM CS 1000, CENTUM CS 3000 Entry Class R3.09.50 and earlier, CENTUM VP R5.03.00 and earlier, CENTUM VP Entry Class R5.03.00 and earlier, Exaopc R3.71.02 and earlier, B/M9000CS R5.05.01 and earlier, and B/M9000 VP R7.03.01 and earlier allows remote attackers to execute arbitrary code via a crafted packet.
Severity
No CVSS data available.
CWE
Assigner
Impacted products
Vendor Product Version
Yokogawa CENTUM CS 3000 Affected: 0 , < R3.09.50 (custom)
Create a notification for this product.
Date Public
2014-03-11 06:00
Credits
Juan Vazquez of Rapid7 Inc.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T09:27:19.445Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.yokogawa.com/dcs/security/ysar/YSAR-14-0001E.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-133-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "CENTUM CS 3000",
          "vendor": "Yokogawa",
          "versions": [
            {
              "lessThan": "R3.09.50",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Juan Vazquez of Rapid7 Inc."
        }
      ],
      "datePublic": "2014-03-11T06:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003e\n\n\nStack-based buffer overflow in BKESimmgr.exe in the Expanded Test Functions package in Yokogawa CENTUM CS 1000, CENTUM CS 3000 Entry Class R3.09.50 and earlier, CENTUM VP R5.03.00 and earlier, CENTUM VP Entry Class R5.03.00 and earlier, Exaopc R3.71.02 and earlier, B/M9000CS R5.05.01 and earlier, and B/M9000 VP R7.03.01 and earlier allows remote attackers to execute arbitrary code via a crafted packet.\n\n\u003c/p\u003e"
            }
          ],
          "value": "Stack-based buffer overflow in BKESimmgr.exe in the Expanded Test Functions package in Yokogawa CENTUM CS 1000, CENTUM CS 3000 Entry Class R3.09.50 and earlier, CENTUM VP R5.03.00 and earlier, CENTUM VP Entry Class R5.03.00 and earlier, Exaopc R3.71.02 and earlier, B/M9000CS R5.05.01 and earlier, and B/M9000 VP R7.03.01 and earlier allows remote attackers to execute arbitrary code via a crafted packet."
        }
      ],
      "metrics": [
        {
          "cvssV2_0": {
            "accessComplexity": "MEDIUM",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "availabilityImpact": "COMPLETE",
            "baseScore": 8.3,
            "confidentialityImpact": "PARTIAL",
            "integrityImpact": "PARTIAL",
            "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:C",
            "version": "2.0"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-09-25T17:27:46.585Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-14-070-01a"
        },
        {
          "name": "66130",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/66130"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://community.rapid7.com/community/metasploit/blog/2014/03/10/yokogawa-centum-cs3000-vulnerabilities"
        },
        {
          "url": "http://www.yokogawa.com/dcs/security/ysar/dcs-ysar-index-en.htm."
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eYokogawa has created a patch (CENTUM CS 3000 R3.09.73 and R3.09.75) to mitigate the reported vulnerabilities. To activate the patch software, the computer needs to be rebooted. Older versions of the CENTUM CS 3000 will need to be updated to the latest version of R3.09.50 before installing the patch software.\u003cbr\u003e\u003c/p\u003e\u003cp\u003eYokogawa also suggests all customers introduce appropriate security measures to the overall system, not just for the vulnerabilities identified.\u003c/p\u003e\u003cp\u003eFor more information, please see the advisory that Yokogawa has published regarding this issue here: \u003ca target=\"_blank\" rel=\"nofollow\" href=\"http://www.yokogawa.com/dcs/security/ysar/dcs-ysar-index-en.htm\"\u003ehttp://www.yokogawa.com/dcs/security/ysar/dcs-ysar-index-en.htm\u003c/a\u003e.\u003c/p\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "Yokogawa has created a patch (CENTUM CS 3000 R3.09.73 and R3.09.75) to mitigate the reported vulnerabilities. To activate the patch software, the computer needs to be rebooted. Older versions of the CENTUM CS 3000 will need to be updated to the latest version of R3.09.50 before installing the patch software.\n\n\nYokogawa also suggests all customers introduce appropriate security measures to the overall system, not just for the vulnerabilities identified.\n\nFor more information, please see the advisory that Yokogawa has published regarding this issue here:  http://www.yokogawa.com/dcs/security/ysar/dcs-ysar-index-en.htm ."
        }
      ],
      "source": {
        "advisory": "ICSA-14-070-01",
        "discovery": "EXTERNAL"
      },
      "title": "Yokogawa CENTUM CS 3000 Stack-based Buffer Overflow",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2014-0781",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Heap-based buffer overflow in BKCLogSvr.exe in Yokogawa CENTUM CS 3000 R3.09.50 and earlier allows remote attackers to execute arbitrary code via crafted UDP packets."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://ics-cert.us-cert.gov/advisories/ICSA-14-070-01",
              "refsource": "MISC",
              "url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-070-01"
            },
            {
              "name": "66130",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/66130"
            },
            {
              "name": "https://community.rapid7.com/community/metasploit/blog/2014/03/10/yokogawa-centum-cs3000-vulnerabilities",
              "refsource": "MISC",
              "url": "https://community.rapid7.com/community/metasploit/blog/2014/03/10/yokogawa-centum-cs3000-vulnerabilities"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2014-0782",
    "datePublished": "2014-05-16T10:00:00.000Z",
    "dateReserved": "2014-01-02T00:00:00.000Z",
    "dateUpdated": "2025-09-25T17:27:46.585Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2014-0774 (GCVE-0-2014-0774)

Vulnerability from cvelistv5 – Published: 2014-02-28 02:00 – Updated: 2025-09-24 21:10
VLAI
Title
Schneider Electric OFS Stack Buffer Overflow
Summary
Stack-based buffer overflow in the C++ sample client in Schneider Electric OPC Factory Server (OFS) TLXCDSUOFS33 - 3.35, TLXCDSTOFS33 - 3.35, TLXCDLUOFS33 - 3.35, TLXCDLTOFS33 - 3.35, and TLXCDLFOFS33 - 3.35 allows local users to gain privileges via vectors involving a malformed configuration file.
Severity
No CVSS data available.
CWE
Assigner
Date Public
2014-02-27 07:00
Credits
Schneider Electric
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T09:27:19.467Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-058-02"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD%202014-031-01"
          },
          {
            "name": "65871",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/65871"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "TLXCDSUOFS33",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "V3.35"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TLXCDSTOFS33",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "V3.35"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TLXCDLUOFS33",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "V3.35"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TLXCDLTOFS33",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "V3.35"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TLXCDLFOFS33",
          "vendor": "Schneider Electric",
          "versions": [
            {
              "status": "affected",
              "version": "V3.35"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Schneider Electric"
        }
      ],
      "datePublic": "2014-02-27T07:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eStack-based buffer overflow in the C++ sample client in Schneider Electric OPC Factory Server (OFS) TLXCDSUOFS33 - 3.35, TLXCDSTOFS33 - 3.35, TLXCDLUOFS33 - 3.35, TLXCDLTOFS33 - 3.35, and TLXCDLFOFS33 - 3.35 allows local users to gain privileges via vectors involving a malformed configuration file.\u003c/p\u003e"
            }
          ],
          "value": "Stack-based buffer overflow in the C++ sample client in Schneider Electric OPC Factory Server (OFS) TLXCDSUOFS33 - 3.35, TLXCDSTOFS33 - 3.35, TLXCDLUOFS33 - 3.35, TLXCDLTOFS33 - 3.35, and TLXCDLFOFS33 - 3.35 allows local users to gain privileges via vectors involving a malformed configuration file."
        }
      ],
      "metrics": [
        {
          "cvssV2_0": {
            "accessComplexity": "LOW",
            "accessVector": "LOCAL",
            "authentication": "SINGLE",
            "availabilityImpact": "COMPLETE",
            "baseScore": 6.8,
            "confidentialityImpact": "COMPLETE",
            "integrityImpact": "COMPLETE",
            "vectorString": "AV:L/AC:L/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-09-24T21:10:10.144Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-14-058-02"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD%202014-031-01"
        },
        {
          "name": "65871",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/65871"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eSchneider Electric has a product upgrade as well as a workaround \nsolution \nthat mitigates this \nvulnerability.\u0026nbsp;\u003c/p\u003e\u003cp\u003eSchneider Electric Security Notification SEVD \n2014-031-01,\u201dVulnerability Disclosure \u2013 OPC Factory Server V3.35,\u201d \n\u003ca target=\"_blank\" rel=\"nofollow\" href=\"http://www.downloads.schneider-electric.com/?p_Conf=\u0026amp;p_localesFilter=\u0026amp;p_docTypeFilter=1555899,\u0026amp;p_docTypeGroupFilter=3541958\"\u003ehttp://www.downloads.schneider-electric.com/?p_Conf=\u0026amp;p_localesFilter=\u0026amp;p_docTypeFilter=155589...\u003c/a\u003e\u0026nbsp; \u0026nbsp;\u003c/p\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe security announcements affecting the OPC Factory Server are available here:\u003c/p\u003e\n\u003cp\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"http://www2.schneider-electric.com/sites/corporate/en/support/cybersecurity/cybersecurity.page\"\u003ehttp://www2.schneider-electric.com/sites/corporate/en/support/cybersecurity/cybersecurity.page\u003c/a\u003e\u003c/p\u003e\u003c/div\u003eSchneider\n Electric recommends customers to upgrade to OFS v3.4 or later (Version \nv3.5 is currently available). Customers that cannot upgrade are directed\n to remove the demonstration client from affected computers, provided it\n is not required for operations.\n\n\u003cbr\u003e"
            }
          ],
          "value": "Schneider Electric has a product upgrade as well as a workaround \nsolution \nthat mitigates this \nvulnerability.\u00a0\n\nSchneider Electric Security Notification SEVD \n2014-031-01,\u201dVulnerability Disclosure \u2013 OPC Factory Server V3.35,\u201d \n http://www.downloads.schneider-electric.com/?p_Conf=\u0026p_localesFilter=\u0026p_docTypeFilter=155589... http://www.downloads.schneider-electric.com/ \u00a0 \u00a0\n\n\n\nThe security announcements affecting the OPC Factory Server are available here:\n\n\n http://www2.schneider-electric.com/sites/corporate/en/support/cybersecurity/cybersecurity.page \n\n\n\nSchneider\n Electric recommends customers to upgrade to OFS v3.4 or later (Version \nv3.5 is currently available). Customers that cannot upgrade are directed\n to remove the demonstration client from affected computers, provided it\n is not required for operations."
        }
      ],
      "source": {
        "advisory": "ICSA-14-058-02",
        "discovery": "INTERNAL"
      },
      "title": "Schneider Electric OFS Stack Buffer Overflow",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2014-0774",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Stack-based buffer overflow in the C++ sample client in Schneider Electric OPC Factory Server (OFS) TLXCDSUOFS33 - 3.35, TLXCDSTOFS33 - 3.35, TLXCDLUOFS33 - 3.35, TLXCDLTOFS33 - 3.35, and TLXCDLFOFS33 - 3.35 allows local users to gain privileges via vectors involving a malformed configuration file."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://ics-cert.us-cert.gov/advisories/ICSA-14-058-02",
              "refsource": "MISC",
              "url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-058-02"
            },
            {
              "name": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD%202014-031-01",
              "refsource": "CONFIRM",
              "url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD%202014-031-01"
            },
            {
              "name": "65871",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/65871"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2014-0774",
    "datePublished": "2014-02-28T02:00:00.000Z",
    "dateReserved": "2014-01-02T00:00:00.000Z",
    "dateUpdated": "2025-09-24T21:10:10.144Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

Mitigation MIT-10
Operation Build and Compilation

Strategy: Environment Hardening

  • Use automatic buffer overflow detection mechanisms that are offered by certain compilers or compiler extensions. Examples include: the Microsoft Visual Studio /GS flag, Fedora/Red Hat FORTIFY_SOURCE GCC flag, StackGuard, and ProPolice, which provide various mechanisms including canary-based detection and range/index checking.
  • D3-SFCV (Stack Frame Canary Validation) from D3FEND [REF-1334] discusses canary-based detection in detail.
Mitigation
Architecture and Design

Use an abstraction library to abstract away risky APIs. Not a complete solution.

Mitigation
Implementation

Implement and perform bounds checking on input.

Mitigation
Implementation

Do not use dangerous functions such as gets. Use safer, equivalent functions which check for boundary errors.

Mitigation MIT-11
Operation Build and Compilation

Strategy: Environment Hardening

  • Run or compile the software using features or extensions that randomly arrange the positions of a program's executable and libraries in memory. Because this makes the addresses unpredictable, it can prevent an attacker from reliably jumping to exploitable code.
  • Examples include Address Space Layout Randomization (ASLR) [REF-58] [REF-60] and Position-Independent Executables (PIE) [REF-64]. Imported modules may be similarly realigned if their default memory addresses conflict with other modules, in a process known as "rebasing" (for Windows) and "prelinking" (for Linux) [REF-1332] using randomly generated addresses. ASLR for libraries cannot be used in conjunction with prelink since it would require relocating the libraries at run-time, defeating the whole purpose of prelinking.
  • For more information on these techniques see D3-SAOR (Segment Address Offset Randomization) from D3FEND [REF-1335].

No CAPEC attack patterns related to this CWE.