CVE-2024-7059 (GCVE-0-2024-7059)
Vulnerability from cvelistv5 – Published: 2024-11-05 13:13 – Updated: 2024-11-09 22:45
VLAI
EPSS
VEX
Summary
A high-severity vulnerability that can lead to arbitrary code execution on the system hosting the Web SDK role was found in the Genetec Security Center product line.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-11-05 15:06 UTC
CWE
- CWE-470 - Use of Externally-Controlled Input to Select Classes or Code ('Unsafe Reflection')
Assigner
References
Impacted products
2 products
| Vendor | Product | Version | CPE status | |
|---|---|---|---|---|
| Genetec Inc. | Genetec Security Center |
Affected:
<5.8.2.1
(semver)
Unaffected: >=5.8.2.1 (semver) Affected: >=5.9.0.0 <5.9.5.8 (semver) Unaffected: >=5.9.5.8 (semver) Affected: >=5.10.0.0 <5.10.4.23 (semver) Unaffected: >=5.10.4.23 (semver) Affected: >=5.11.0.0 <5.11.3.13 (semver) Unaffected: >=5.11.3.13 (semver) Affected: >=5.12.0.0 <5.12.1.3 (semver) Unaffected: >=5.12.1.3 <5.12.2.0 (semver) Affected: >=5.12.2.0 <5.12.2.1 (semver) Unaffected: >=5.12.2.1 (semver) |
guessed | |
| genetec | security_center |
Affected:
0 , < 5.8.2.1
(semver)
Affected: 5.9.0.0 , < 5.9.5.8 (semver) Affected: 5.10.0.0 , < 5.10.4.23 (semver) Affected: 5.11.0.0 , < 5.11.3.13 (semver) Affected: 5.12.0.0 , < 5.12.1.3 (semver) Affected: 5.12.2.0 , < 5.12.2.1 (semver) cpe:2.3:a:genetec:security_center:*:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:genetec:security_center:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "security_center",
"vendor": "genetec",
"versions": [
{
"lessThan": "5.8.2.1",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "5.9.5.8",
"status": "affected",
"version": "5.9.0.0",
"versionType": "semver"
},
{
"lessThan": "5.10.4.23",
"status": "affected",
"version": "5.10.0.0",
"versionType": "semver"
},
{
"lessThan": "5.11.3.13",
"status": "affected",
"version": "5.11.0.0",
"versionType": "semver"
},
{
"lessThan": "5.12.1.3",
"status": "affected",
"version": "5.12.0.0",
"versionType": "semver"
},
{
"lessThan": "5.12.2.1",
"status": "affected",
"version": "5.12.2.0",
"versionType": "semver"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-7059",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-05T15:06:17.075211Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-05T15:11:38.336Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"platforms": [
"Windows"
],
"product": "Genetec Security Center",
"vendor": "Genetec Inc.",
"versions": [
{
"status": "affected",
"version": "\u003c5.8.2.1",
"versionType": "semver"
},
{
"status": "unaffected",
"version": "\u003e=5.8.2.1",
"versionType": "semver"
},
{
"status": "affected",
"version": "\u003e=5.9.0.0 \u003c5.9.5.8",
"versionType": "semver"
},
{
"status": "unaffected",
"version": "\u003e=5.9.5.8",
"versionType": "semver"
},
{
"status": "affected",
"version": "\u003e=5.10.0.0 \u003c5.10.4.23",
"versionType": "semver"
},
{
"status": "unaffected",
"version": "\u003e=5.10.4.23",
"versionType": "semver"
},
{
"status": "affected",
"version": "\u003e=5.11.0.0 \u003c5.11.3.13",
"versionType": "semver"
},
{
"status": "unaffected",
"version": "\u003e=5.11.3.13",
"versionType": "semver"
},
{
"status": "affected",
"version": "\u003e=5.12.0.0 \u003c5.12.1.3",
"versionType": "semver"
},
{
"status": "unaffected",
"version": "\u003e=5.12.1.3 \u003c5.12.2.0",
"versionType": "semver"
},
{
"status": "affected",
"version": "\u003e=5.12.2.0 \u003c5.12.2.1",
"versionType": "semver"
},
{
"status": "unaffected",
"version": "\u003e=5.12.2.1",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "AlgoSecure, Louis Moubinous"
}
],
"descriptions": [
{
"lang": "en",
"value": "A high-severity vulnerability that can lead to arbitrary code execution on the system hosting the Web SDK role was found in the Genetec Security Center product line."
}
],
"impacts": [
{
"capecId": "CAPEC-138",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-138: Reflection Injection"
}
]
}
],
"metrics": [
{
"cvssV3_0": {
"baseScore": 8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:H",
"version": "3.0"
},
"cvssV3_1": {
"baseScore": 8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"cvssV4_0": {
"baseScore": 8.9,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:H/AT:P/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
"version": "4.0"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-470",
"description": "CWE-470 Use of Externally-Controlled Input to Select Classes or Code (\u0027Unsafe Reflection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-11-09T22:45:41.270Z",
"orgId": "f2b06212-cb4b-41a4-9501-fa2e367495b8",
"shortName": "Genetec"
},
"references": [
{
"url": "https://resources.genetec.com/security-advisories/high-severity-vulnerability-affecting-security-center-web-sdk-role"
},
{
"url": "https://ressources.genetec.com/bulletins-de-securite/vulnerabilite-de-haute-severite-affectant-le-role-sdk-web-de-security-center"
}
],
"solutions": [
{
"lang": "en",
"value": "This issue is fixed in Security Center 5.8.2.1, 5.9.5.8, 5.10.4.23, 5.11.3.13, 5.12.1.3, 5.12.2.1 and all later versions."
}
],
"workarounds": [
{
"lang": "en",
"value": "If the Security Center instance cannot be updated in a timely fashion, the system administrator should deactivate the Web-based SDK role."
}
]
}
},
"cveMetadata": {
"assignerOrgId": "f2b06212-cb4b-41a4-9501-fa2e367495b8",
"assignerShortName": "Genetec",
"cveId": "CVE-2024-7059",
"datePublished": "2024-11-05T13:13:29.839Z",
"dateReserved": "2024-07-23T20:53:20.464Z",
"dateUpdated": "2024-11-09T22:45:41.270Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2024-7059",
"date": "2026-09-21",
"epss": "0.0055",
"percentile": "0.44642"
},
"nvd": {
"cve": {
"affected": [
{
"affectedData": [
{
"defaultStatus": "unaffected",
"platforms": [
"Windows"
],
"product": "Genetec Security Center",
"vendor": "Genetec Inc.",
"versions": [
{
"status": "affected",
"version": "\u003c5.8.2.1",
"versionType": "semver"
},
{
"status": "unaffected",
"version": "\u003e=5.8.2.1",
"versionType": "semver"
},
{
"status": "affected",
"version": "\u003e=5.9.0.0 \u003c5.9.5.8",
"versionType": "semver"
},
{
"status": "unaffected",
"version": "\u003e=5.9.5.8",
"versionType": "semver"
},
{
"status": "affected",
"version": "\u003e=5.10.0.0 \u003c5.10.4.23",
"versionType": "semver"
},
{
"status": "unaffected",
"version": "\u003e=5.10.4.23",
"versionType": "semver"
},
{
"status": "affected",
"version": "\u003e=5.11.0.0 \u003c5.11.3.13",
"versionType": "semver"
},
{
"status": "unaffected",
"version": "\u003e=5.11.3.13",
"versionType": "semver"
},
{
"status": "affected",
"version": "\u003e=5.12.0.0 \u003c5.12.1.3",
"versionType": "semver"
},
{
"status": "unaffected",
"version": "\u003e=5.12.1.3 \u003c5.12.2.0",
"versionType": "semver"
},
{
"status": "affected",
"version": "\u003e=5.12.2.0 \u003c5.12.2.1",
"versionType": "semver"
},
{
"status": "unaffected",
"version": "\u003e=5.12.2.1",
"versionType": "semver"
}
]
}
],
"source": "security@genetec.com"
},
{
"affectedData": [
{
"cpes": [
"cpe:2.3:a:genetec:security_center:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "security_center",
"vendor": "genetec",
"versions": [
{
"lessThan": "5.8.2.1",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "5.9.5.8",
"status": "affected",
"version": "5.9.0.0",
"versionType": "semver"
},
{
"lessThan": "5.10.4.23",
"status": "affected",
"version": "5.10.0.0",
"versionType": "semver"
},
{
"lessThan": "5.11.3.13",
"status": "affected",
"version": "5.11.0.0",
"versionType": "semver"
},
{
"lessThan": "5.12.1.3",
"status": "affected",
"version": "5.12.0.0",
"versionType": "semver"
},
{
"lessThan": "5.12.2.1",
"status": "affected",
"version": "5.12.2.0",
"versionType": "semver"
}
]
}
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A high-severity vulnerability that can lead to arbitrary code execution on the system hosting the Web SDK role was found in the Genetec Security Center product line."
},
{
"lang": "es",
"value": "Se encontr\u00f3 una vulnerabilidad de alta gravedad que puede llevar a la ejecuci\u00f3n de c\u00f3digo arbitrario en la l\u00ednea de productos Genetec Security Center."
}
],
"id": "CVE-2024-7059",
"lastModified": "2026-06-17T08:19:17.050",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.0,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.3,
"impactScore": 6.0,
"source": "security@genetec.com",
"type": "Secondary"
}
],
"cvssMetricV40": [
{
"cvssData": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "HIGH",
"attackRequirements": "PRESENT",
"attackVector": "NETWORK",
"availabilityRequirement": "NOT_DEFINED",
"baseScore": 8.9,
"baseSeverity": "HIGH",
"confidentialityRequirement": "NOT_DEFINED",
"exploitMaturity": "NOT_DEFINED",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"privilegesRequired": "HIGH",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "HIGH",
"subIntegrityImpact": "HIGH",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:H/AT:P/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"source": "security@genetec.com",
"type": "Secondary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2024-7059",
"options": [
{
"exploitation": "none"
},
{
"automatable": "no"
},
{
"technicalImpact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-05T15:06:17.075211Z",
"version": "2.0.3"
}
}
]
},
"published": "2024-11-05T13:15:03.963",
"references": [
{
"source": "security@genetec.com",
"url": "https://resources.genetec.com/security-advisories/high-severity-vulnerability-affecting-security-center-web-sdk-role"
},
{
"source": "security@genetec.com",
"url": "https://ressources.genetec.com/bulletins-de-securite/vulnerabilite-de-haute-severite-affectant-le-role-sdk-web-de-security-center"
}
],
"sourceIdentifier": "security@genetec.com",
"vulnStatus": "Deferred",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-470"
}
],
"source": "security@genetec.com",
"type": "Secondary"
}
]
}
},
"redhat_vex": {
"current_release_date": "2025-05-28T18:49:33+00:00",
"cve": "CVE-2024-7059",
"id": "CVE-2024-7059",
"initial_release_date": "2024-01-01T00:00:00+00:00",
"product_status:known_not_affected": "1",
"source": "Red Hat CSAF VEX",
"status": "final",
"title": "CVE-2024-7059",
"url": "https://security.access.redhat.com/data/csaf/v2/vex/2024/cve-2024-7059.json",
"version": "3"
},
"vulnrichment": {
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:genetec:security_center:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "security_center",
"vendor": "genetec",
"versions": [
{
"lessThan": "5.8.2.1",
"status": "affected",
"version": "0",
"versionType": "semver"
},
{
"lessThan": "5.9.5.8",
"status": "affected",
"version": "5.9.0.0",
"versionType": "semver"
},
{
"lessThan": "5.10.4.23",
"status": "affected",
"version": "5.10.0.0",
"versionType": "semver"
},
{
"lessThan": "5.11.3.13",
"status": "affected",
"version": "5.11.0.0",
"versionType": "semver"
},
{
"lessThan": "5.12.1.3",
"status": "affected",
"version": "5.12.0.0",
"versionType": "semver"
},
{
"lessThan": "5.12.2.1",
"status": "affected",
"version": "5.12.2.0",
"versionType": "semver"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-7059",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-05T15:06:17.075211Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-05T15:11:24.675Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"platforms": [
"Windows"
],
"product": "Genetec Security Center",
"vendor": "Genetec Inc.",
"versions": [
{
"status": "affected",
"version": "\u003c5.8.2.1",
"versionType": "semver"
},
{
"status": "unaffected",
"version": "\u003e=5.8.2.1",
"versionType": "semver"
},
{
"status": "affected",
"version": "\u003e=5.9.0.0 \u003c5.9.5.8",
"versionType": "semver"
},
{
"status": "unaffected",
"version": "\u003e=5.9.5.8",
"versionType": "semver"
},
{
"status": "affected",
"version": "\u003e=5.10.0.0 \u003c5.10.4.23",
"versionType": "semver"
},
{
"status": "unaffected",
"version": "\u003e=5.10.4.23",
"versionType": "semver"
},
{
"status": "affected",
"version": "\u003e=5.11.0.0 \u003c5.11.3.13",
"versionType": "semver"
},
{
"status": "unaffected",
"version": "\u003e=5.11.3.13",
"versionType": "semver"
},
{
"status": "affected",
"version": "\u003e=5.12.0.0 \u003c5.12.1.3",
"versionType": "semver"
},
{
"status": "unaffected",
"version": "\u003e=5.12.1.3 \u003c5.12.2.0",
"versionType": "semver"
},
{
"status": "affected",
"version": "\u003e=5.12.2.0 \u003c5.12.2.1",
"versionType": "semver"
},
{
"status": "unaffected",
"version": "\u003e=5.12.2.1",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "AlgoSecure, Louis Moubinous"
}
],
"descriptions": [
{
"lang": "en",
"value": "A high-severity vulnerability that can lead to arbitrary code execution on the system hosting the Web SDK role was found in the Genetec Security Center product line."
}
],
"impacts": [
{
"capecId": "CAPEC-138",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-138: Reflection Injection"
}
]
}
],
"metrics": [
{
"cvssV3_0": {
"baseScore": 8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:H",
"version": "3.0"
},
"cvssV3_1": {
"baseScore": 8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"cvssV4_0": {
"baseScore": 8.9,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:H/AT:P/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
"version": "4.0"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-470",
"description": "CWE-470 Use of Externally-Controlled Input to Select Classes or Code (\u0027Unsafe Reflection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-11-09T22:45:41.270Z",
"orgId": "f2b06212-cb4b-41a4-9501-fa2e367495b8",
"shortName": "Genetec"
},
"references": [
{
"url": "https://resources.genetec.com/security-advisories/high-severity-vulnerability-affecting-security-center-web-sdk-role"
},
{
"url": "https://ressources.genetec.com/bulletins-de-securite/vulnerabilite-de-haute-severite-affectant-le-role-sdk-web-de-security-center"
}
],
"solutions": [
{
"lang": "en",
"value": "This issue is fixed in Security Center 5.8.2.1, 5.9.5.8, 5.10.4.23, 5.11.3.13, 5.12.1.3, 5.12.2.1 and all later versions."
}
],
"workarounds": [
{
"lang": "en",
"value": "If the Security Center instance cannot be updated in a timely fashion, the system administrator should deactivate the Web-based SDK role."
}
]
}
},
"cveMetadata": {
"assignerOrgId": "f2b06212-cb4b-41a4-9501-fa2e367495b8",
"assignerShortName": "Genetec",
"cveId": "CVE-2024-7059",
"datePublished": "2024-11-05T13:13:29.839Z",
"dateReserved": "2024-07-23T20:53:20.464Z",
"dateUpdated": "2024-11-09T22:45:41.270Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Loading…
Loading…
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
The MITRE ATT&CK techniques below are AI-generated suggestions, inferred from the description of the
vulnerability by the CIRCL/vulnerability-attack-technique-classification-roberta-base
model, served locally by ML-Gateway.
They have not been verified by an analyst and are provided for guidance only.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Loading…
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.
Loading…