CVE-2024-51139 (GCVE-0-2024-51139)

Vulnerability from cvelistv5 – Published: 2025-02-27 00:00 – Updated: 2026-07-05 00:56
VLAI
Summary
Buffer Overflow vulnerability in Vigor2620/LTE200 3.9.8.9 and earlier and Vigor2860/2925 3.9.8 and earlier and Vigor2862/2926 3.9.9.5 and earlier and Vigor2133/2762/2832 3.9.9 and earlier and Vigor165/166 4.2.7 and earlier and Vigor2135/2765/2766 4.4.5.1 and earlier and Vigor2865/2866/2927 4.4.5.3 and earlier and Vigor2962/3910 4.3.2.8/4.4.3.1 and earlier and Vigor3912 4.3.6.1 and earlier allows a remote attacker to execute arbitrary code via the CGI parser's handling of the "Content-Length" header of HTTP POST requests.
SSVC
Exploitation: none Automatable: yes Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-02-28 16:59 UTC
CWE
  • n/a
  • CWE-120 - Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2024-51139",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-02-28T16:59:54.401854Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-120",
                "description": "CWE-120 Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-02-28T17:23:14.780Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Buffer Overflow vulnerability in Vigor2620/LTE200 3.9.8.9 and earlier and Vigor2860/2925 3.9.8 and earlier and Vigor2862/2926 3.9.9.5 and earlier and Vigor2133/2762/2832 3.9.9 and earlier and Vigor165/166 4.2.7 and earlier and Vigor2135/2765/2766 4.4.5.1 and earlier and Vigor2865/2866/2927 4.4.5.3 and earlier and Vigor2962/3910 4.3.2.8/4.4.3.1 and earlier and Vigor3912 4.3.6.1 and earlier allows a remote attacker to execute arbitrary code via the CGI parser\u0027s handling of the \"Content-Length\" header of HTTP POST requests."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-07-05T00:56:37.793Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://medium.com/faraday/advisory-multiple-vulnerabilities-affecting-draytek-routers-78a6cb8b3946"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2024-51139",
    "datePublished": "2025-02-27T00:00:00.000Z",
    "dateReserved": "2024-10-28T00:00:00.000Z",
    "dateUpdated": "2026-07-05T00:56:37.793Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2024-51139",
      "date": "2026-09-20",
      "epss": "0.00995",
      "percentile": "0.61133"
    },
    "nvd": {
      "cve": {
        "affected": [
          {
            "affectedData": [
              {
                "product": "n/a",
                "vendor": "n/a",
                "versions": [
                  {
                    "status": "affected",
                    "version": "n/a"
                  }
                ]
              }
            ],
            "source": "cve@mitre.org"
          }
        ],
        "configurations": [
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:draytek:vigor2620_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "5485DD5C-12A3-4289-8196-43FFB3DF8B06",
                    "versionEndExcluding": "3.9.9.1",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:draytek:vigor2620:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "5D98663B-F2F5-4ADC-9FD5-75846890EEBA",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:draytek:vigorlte200_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "80EC4363-A351-4117-96CE-1F8B4748FCAC",
                    "versionEndExcluding": "3.9.9.1",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:draytek:vigorlte200:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "4DBF2015-9315-44C8-A9FE-E86146F1958E",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:draytek:vigor2860_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "519DD534-4B4A-48A4-9C5D-FB197DC5C777",
                    "versionEndExcluding": "3.9.8.3",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:draytek:vigor2860:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "266C73DE-BFC6-4F3E-B022-559B3971CA44",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:draytek:vigor2925_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "FFCA64D1-9731-4990-AD61-F673D41716BE",
                    "versionEndExcluding": "3.9.8.3",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:draytek:vigor2925:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "7536B29C-2030-4331-B8BF-D269D86D199B",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:draytek:vigor2862_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "2821747D-FDE2-47FA-B352-70F6FBE0473D",
                    "versionEndExcluding": "3.9.9.8",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:draytek:vigor2862:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "8B01EDAE-BB9E-4431-BE8C-6505BA7CA42D",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:draytek:vigor2926_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "ADD3195E-BA40-40B3-AF13-64AFF4890EE4",
                    "versionEndExcluding": "3.9.9.8",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:draytek:vigor2926:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "AF1B117B-603D-493C-A804-C18ED332A221",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:draytek:vigor2133_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "F53804E7-59F0-4328-A732-9A14EB076E87",
                    "versionEndExcluding": "3.9.9.2",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:draytek:vigor2133:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "1878E59C-FB40-435D-940A-8952C56FA88B",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:draytek:vigor2762_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "42C4DE6D-EE26-4445-8F57-0DCEC311A6A2",
                    "versionEndExcluding": "3.9.9.2",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:draytek:vigor2762:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "3873B2B9-95C1-4F00-9165-7C4D2A90CDE5",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:draytek:vigor2832_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "FC78800A-438E-4B67-B3A5-F18D10F5D9B5",
                    "versionEndExcluding": "3.9.9.2",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:draytek:vigor2832:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "B0978465-D59F-4C0A-A29F-5D7BE58BA557",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:draytek:vigor2135_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "5CBCFE34-3027-4DBB-9214-4CC891865F25",
                    "versionEndExcluding": "4.4.5.5",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:draytek:vigor2135:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "AEDC8A7F-08CF-44D2-A9A5-A1353AF35B45",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:draytek:vigor2765_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "162BD269-E656-4A91-9E8C-A5E26A646B2D",
                    "versionEndExcluding": "4.4.5.5",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:draytek:vigor2765:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "60657812-D3A8-4B1B-B7BE-F629991CB053",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:draytek:vigor2766_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "9695AA4E-EC4A-4F02-BFCD-5308CBE19510",
                    "versionEndExcluding": "4.4.5.5",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:draytek:vigor2766:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "C0AB3C84-67CA-4531-85FB-1A56F3C93ABF",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:draytek:vigor2763_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "7ECD7087-34D5-4841-97D1-B9F361327016",
                    "versionEndExcluding": "4.4.5.5",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:draytek:vigor2763:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "9EA9DF5D-6651-455A-9305-C42C0FF51F01",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:draytek:vigor2865_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "45D6CD9B-5252-4541-9745-3F4E4D0C5C82",
                    "versionEndExcluding": "4.4.5.8",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:draytek:vigor2865:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "871448C6-9183-4828-A287-05F5EC6A44F6",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:draytek:vigor2866_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "F40A5ACD-BC60-4C97-BF7D-6B609A1D99E6",
                    "versionEndExcluding": "4.4.5.8",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:draytek:vigor2866:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "0D0D2760-739F-4C79-AEDC-8B2CCCA2FF53",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:draytek:vigor2927_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "74715D2C-FDF6-4882-A57A-327014FCC1CB",
                    "versionEndExcluding": "4.4.5.8",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:draytek:vigor2927:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "12460F51-25AB-4EA9-BC43-9CE8DA992D75",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:draytek:vigor2962_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "093FCEE3-FEAA-4DA5-AD20-206D3822C63F",
                    "versionEndExcluding": "4.3.2.9",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:o:draytek:vigor2962_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "94AD7401-FE5B-4E5F-9469-DEDB101C6990",
                    "versionEndExcluding": "4.4.3.2",
                    "versionStartIncluding": "4.4.3",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:draytek:vigor2962:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "BD0C9A21-7CFE-452F-8505-834AB8579D9B",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:draytek:vigor3910_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "529BDB13-03F3-4EF4-A15C-4EF2467DF5AE",
                    "versionEndExcluding": "4.3.2.9",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:o:draytek:vigor3910_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "6F18DFF3-93B4-462C-908E-99C243EFFA2F",
                    "versionEndExcluding": "4.4.3.2",
                    "versionStartIncluding": "4.4.3",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:draytek:vigor3910:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "894E4DDA-D9BE-441D-B447-B1CE52959347",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:draytek:vigor3912_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "6AD4EA0F-391C-4A2E-B5CD-0D0689C36F20",
                    "versionEndExcluding": "4.4.3.2",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:draytek:vigor3912:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "282E5318-DAA8-4AA2-8E7D-4B8BD9162153",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:draytek:vigor2915_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "A876E867-03E8-470E-A830-C0C5FBCCB257",
                    "versionEndExcluding": "4.4.5",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:draytek:vigor2915:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "5860CBE4-328E-418D-9E81-1D3AF7DB8F2B",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:draytek:vigor1000b_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "B75C80CA-401A-4228-98F9-D27E529DC32D",
                    "versionEndExcluding": "4.4.3.2",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:draytek:vigor1000b:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "9FF86645-253A-4BA3-BA2A-2725575C390D",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:draytek:vigor2952_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "F39C5A58-E6F1-4BA5-B321-7EA78F8DC7A6",
                    "versionEndExcluding": "3.9.8.5",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:draytek:vigor2952:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "167336E2-AAA8-4424-AB07-2D7C9E1542B3",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:draytek:vigor3220_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "85DA10A6-CA24-4D03-B4DC-CC9A33D7E22D",
                    "versionEndExcluding": "3.9.8.5",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:draytek:vigor3220:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "64955940-3998-4B76-92D1-D9F3FAB874B4",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "Buffer Overflow vulnerability in Vigor2620/LTE200 3.9.8.9 and earlier and Vigor2860/2925 3.9.8 and earlier and Vigor2862/2926 3.9.9.5 and earlier and Vigor2133/2762/2832 3.9.9 and earlier and Vigor165/166 4.2.7 and earlier and Vigor2135/2765/2766 4.4.5.1 and earlier and Vigor2865/2866/2927 4.4.5.3 and earlier and Vigor2962/3910 4.3.2.8/4.4.3.1 and earlier and Vigor3912 4.3.6.1 and earlier allows a remote attacker to execute arbitrary code via the CGI parser\u0027s handling of the \"Content-Length\" header of HTTP POST requests."
          },
          {
            "lang": "es",
            "value": "Buffer Overflow vulnerability in Vigor2620/LTE200 3.9.8.9 and earlier and Vigor2860/2925 3.9.8 and earlier and Vigor2862/2926 3.9.9.5 and earlier and Vigor2133/2762/2832 3.9.9 and earlier and Vigor165/166 4.2.7 and earlier and Vigor2135/2765/2766 4.4.5.1 and earlier and Vigor2865/2866/2927 4.4.5.3 and earlier and Vigor2962/3910 4.3.2.8/4.4.3.1 and earlier and Vigor3912 4.3.6.1 and earlier allows a remote attacker to execute arbitrary code via the CGI parser\u0027s handling of the \"Content-Length\" header of HTTP POST requests."
          }
        ],
        "id": "CVE-2024-51139",
        "lastModified": "2026-07-05T01:21:02.200",
        "metrics": {
          "cvssMetricV31": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "exploitabilityScore": 3.9,
              "impactScore": 5.9,
              "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "type": "Secondary"
            }
          ],
          "ssvcV203": [
            {
              "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "ssvcData": {
                "id": "CVE-2024-51139",
                "options": [
                  {
                    "exploitation": "none"
                  },
                  {
                    "automatable": "yes"
                  },
                  {
                    "technicalImpact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-02-28T16:59:54.401854Z",
                "version": "2.0.3"
              }
            }
          ]
        },
        "published": "2025-02-27T21:15:37.123",
        "references": [
          {
            "source": "cve@mitre.org",
            "tags": [
              "Third Party Advisory"
            ],
            "url": "https://medium.com/faraday/advisory-multiple-vulnerabilities-affecting-draytek-routers-78a6cb8b3946"
          }
        ],
        "sourceIdentifier": "cve@mitre.org",
        "vulnStatus": "Modified",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-120"
              }
            ],
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "type": "Secondary"
          }
        ]
      }
    },
    "vulnrichment": {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 9.8,
                  "baseSeverity": "CRITICAL",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-51139",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-02-28T16:59:54.401854Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-120",
                    "description": "CWE-120 Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-02-28T17:23:11.150Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Buffer Overflow vulnerability in Vigor2620/LTE200 3.9.8.9 and earlier and Vigor2860/2925 3.9.8 and earlier and Vigor2862/2926 3.9.9.5 and earlier and Vigor2133/2762/2832 3.9.9 and earlier and Vigor165/166 4.2.7 and earlier and Vigor2135/2765/2766 4.4.5.1 and earlier and Vigor2865/2866/2927 4.4.5.3 and earlier and Vigor2962/3910 4.3.2.8/4.4.3.1 and earlier and Vigor3912 4.3.6.1 and earlier allows a remote attacker to execute arbitrary code via the CGI parser\u0027s handling of the \"Content-Length\" header of HTTP POST requests."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-02-27T20:47:37.278Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "http://draytek.com"
            },
            {
              "url": "https://medium.com/faraday/advisory-multiple-vulnerabilities-affecting-draytek-routers-78a6cb8b3946"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2024-51139",
        "datePublished": "2025-02-27T00:00:00.000Z",
        "dateReserved": "2024-10-28T00:00:00.000Z",
        "dateUpdated": "2025-02-28T17:23:14.780Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…