CVE-2023-37220 (GCVE-0-2023-37220)

Vulnerability from cvelistv5 – Published: 2023-09-03 13:47 – Updated: 2024-10-01 13:07
VLAI
Title
Synel Terminals - CWE-494: Download of Code Without Integrity Check
Summary
Synel Terminals - CWE-494: Download of Code Without Integrity Check
SSVC
Exploitation: none Automatable: no Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-10-01 13:06 UTC
CWE
  • CWE-494 - Download of Code Without Integrity Check
Impacted products
Vendor Product Version CPE status
Synel Terminals Affected: All versions , < Upgrade to version 3015.1 (custom)
guessed Create a notification for this product.
synel terminals Affected: 0 , < 3015.1 (custom)
    cpe:2.3:a:synel:terminals:*:*:*:*:*:*:*:*
Create a notification for this product.
Date Public
2023-09-03 13:42
Credits
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T17:09:34.169Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.gov.il/en/Departments/faq/cve_advisories"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:synel:terminals:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "terminals",
            "vendor": "synel",
            "versions": [
              {
                "lessThan": "3015.1",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-37220",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-01T13:06:04.073013Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-01T13:07:25.275Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Terminals",
          "vendor": "Synel ",
          "versions": [
            {
              "lessThan": "Upgrade to version 3015.1",
              "status": "affected",
              "version": "All versions",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Elad Ernst"
        }
      ],
      "datePublic": "2023-09-03T13:42:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eSynel Terminals - CWE-494: Download of Code Without Integrity Check\u003c/span\u003e\n\n"
            }
          ],
          "value": "\nSynel Terminals - CWE-494: Download of Code Without Integrity Check\n\n"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.2,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-494",
              "description": "CWE-494 Download of Code Without Integrity Check",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-09-03T13:47:05.388Z",
        "orgId": "a57ee1ae-c9c1-4f40-aa7b-cf10760fde3f",
        "shortName": "INCD"
      },
      "references": [
        {
          "url": "https://www.gov.il/en/Departments/faq/cve_advisories"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eUpgrade to version 3015.1\u003c/span\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "\nUpgrade to version 3015.1\n\n\n"
        }
      ],
      "source": {
        "advisory": "ILVN-2023-0122",
        "discovery": "UNKNOWN"
      },
      "title": "Synel Terminals - CWE-494: Download of Code Without Integrity Check",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "a57ee1ae-c9c1-4f40-aa7b-cf10760fde3f",
    "assignerShortName": "INCD",
    "cveId": "CVE-2023-37220",
    "datePublished": "2023-09-03T13:47:05.388Z",
    "dateReserved": "2023-06-28T20:35:37.792Z",
    "dateUpdated": "2024-10-01T13:07:25.275Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2023-37220",
      "date": "2026-09-22",
      "epss": "0.0032",
      "percentile": "0.25226"
    },
    "nvd": {
      "cve": {
        "affected": [
          {
            "affectedData": [
              {
                "defaultStatus": "unaffected",
                "product": "Terminals",
                "vendor": "Synel ",
                "versions": [
                  {
                    "lessThan": "Upgrade to version 3015.1",
                    "status": "affected",
                    "version": "All versions",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "source": "cna@cyber.gov.il"
          },
          {
            "affectedData": [
              {
                "cpes": [
                  "cpe:2.3:a:synel:terminals:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "terminals",
                "vendor": "synel",
                "versions": [
                  {
                    "lessThan": "3015.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0"
          }
        ],
        "configurations": [
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:synel:synergy\\/a_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "7C3431BE-8E85-40A8-91D9-A3C03C81BF7A",
                    "versionEndExcluding": "3015.1",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:synel:synergy\\/a:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "9CEB5432-74EB-4A98-AA18-897CABE4AF26",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:synel:synergy_touch_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "C883E9CF-C77E-4E78-B138-C557D69B583F",
                    "versionEndExcluding": "3015.1",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:synel:synergy_touch:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "8ADA2E81-0753-44AB-AC4F-6A9A6EE87462",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:synel:synergy_10_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "D2658E86-1253-4D31-819C-4BD3A156FCD2",
                    "versionEndExcluding": "3015.1",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:synel:synergy_10:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "4E30ED62-C10D-4752-8404-BCA4041CA751",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:synel:synergy_5_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "888282C2-093E-4A21-87F1-CFF12E2A9576",
                    "versionEndExcluding": "3015.1",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:synel:synergy_5:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "EA328B75-2CAA-4871-8A20-245916DC6166",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:synel:sy-910_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "BE281DA3-A762-4FB7-B12F-7BA67DE32926",
                    "versionEndExcluding": "3015.1",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:synel:sy-910:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "24057D19-A18A-4E61-8FCD-A15A8D265A2E",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:synel:synergy\\/x_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "D52D69C8-55F7-4859-9329-165CDB166660",
                    "versionEndExcluding": "3015.1",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:synel:synergy\\/x:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "0BBCCEE9-20C5-4370-9D41-62C0B48863BF",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:synel:sy110_face_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "D597621A-1DA4-477F-BDEC-4044E0CB850D",
                    "versionEndExcluding": "3015.1",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:synel:sy110_face:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "CBD33F72-88A6-4B49-9774-740CF8AEFE80",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:synel:bioentry-w2_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "D80201F0-07BF-4223-A783-9602B248B6DB",
                    "versionEndExcluding": "3015.1",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:synel:bioentry-w2:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "D5D4DEC1-E370-43FD-A1C1-26DE3DE1ACFA",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:synel:biolite-n2_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "B2DACD2A-973E-48D4-8125-C03AB69F6FA0",
                    "versionEndExcluding": "3015.1",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:synel:biolite-n2:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "1DE274DA-B3DE-450D-B658-674FECD8E8CC",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:synel:bioentry_p2_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "B1039971-A3F9-4D30-B0DC-1BC10CEADFCC",
                    "versionEndExcluding": "3015.1",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:synel:bioentry_p2:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "6DECFB45-A5E5-40D9-8B4F-3E21745E2E48",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:synel:sy-711_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "DC588814-31C4-436A-ACF4-469BC3644BB8",
                    "versionEndExcluding": "3015.1",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:synel:sy-711:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "578030EB-BE02-404C-B5CC-9AC852BBD927",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:synel:sy-715_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "CEFE13E7-D150-472D-B499-92CADAD3FCE8",
                    "versionEndExcluding": "3015.1",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:synel:sy-715:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "0C967103-DD12-469C-BF9A-7E6BE34BE6B8",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:synel:sy-751_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "69B64275-4D2E-4F1A-B161-1B6DC2EAC5C9",
                    "versionEndExcluding": "3015.1",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:synel:sy-751:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "2FAE8AD6-3D27-44EA-9DF5-41F8B0A74304",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:synel:sy-755_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "FBCD98CD-CF12-435E-849F-C1CAF3ACEC8A",
                    "versionEndExcluding": "3015.1",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:synel:sy-755:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "D0DA4BD0-7918-4215-AC4F-D7EB4421ECD8",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:synel:sy-777_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "6F49A59F-DA31-440D-B8ED-9B85E1F7CAF1",
                    "versionEndExcluding": "3015.1",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:synel:sy-777:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "24A9A9AE-5A7F-4CCB-B4E7-2E017E5C1D73",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:synel:sy-785_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "C9B5E591-3701-406E-9586-1BDF0261019B",
                    "versionEndExcluding": "3015.1",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:synel:sy-785:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "DCAEFF5E-1E8F-470D-A245-40C8D1599E20",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:synel:sy-765_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "91C402A4-80BC-4D5A-96BA-EC12F9DB53AE",
                    "versionEndExcluding": "3015.1",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:synel:sy-765:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "96141CF0-78B4-4377-826B-641AF2ED29EC",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:synel:sy-7500_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "70544D8B-A6AB-4BCA-B548-A2CAD88493B1",
                    "versionEndExcluding": "3015.1",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:synel:sy-7500:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "01B54814-8CCC-44E2-A21D-4F8E34667292",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:synel:sy-745_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "25FE0B6C-2F3D-4390-AAC7-2DE37A2FE44D",
                    "versionEndExcluding": "3015.1",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:synel:sy-745:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "CAFFB4FB-8C79-40BC-B211-DD025A20FB0F",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:synel:sy-780_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "BA44D700-855C-4B6C-8664-308F09DA4986",
                    "versionEndExcluding": "3015.1",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:synel:sy-780:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "6FDF3F5D-DF58-4F92-B825-AEB9BF0B4FCF",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:synel:synergy_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "8D3E71AC-D176-4783-AFD6-4A447F04333B",
                    "versionEndExcluding": "3015.1",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:synel:synergy:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "AD9C87F1-50E6-4A22-8599-24D9C3804F59",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "\nSynel Terminals - CWE-494: Download of Code Without Integrity Check\n\n"
          },
          {
            "lang": "es",
            "value": "Synel Terminals - CWE-494: Descarga de c\u00f3digo sin comprobaci\u00f3n de integridad. "
          }
        ],
        "id": "CVE-2023-37220",
        "lastModified": "2026-06-17T06:07:45.317",
        "metrics": {
          "cvssMetricV31": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 7.2,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "exploitabilityScore": 1.2,
              "impactScore": 5.9,
              "source": "cna@cyber.gov.il",
              "type": "Secondary"
            },
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "exploitabilityScore": 3.9,
              "impactScore": 5.9,
              "source": "nvd@nist.gov",
              "type": "Primary"
            }
          ],
          "ssvcV203": [
            {
              "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "ssvcData": {
                "id": "CVE-2023-37220",
                "options": [
                  {
                    "exploitation": "none"
                  },
                  {
                    "automatable": "no"
                  },
                  {
                    "technicalImpact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-01T13:06:04.073013Z",
                "version": "2.0.3"
              }
            }
          ]
        },
        "published": "2023-09-03T14:15:41.587",
        "references": [
          {
            "source": "cna@cyber.gov.il",
            "tags": [
              "Third Party Advisory"
            ],
            "url": "https://www.gov.il/en/Departments/faq/cve_advisories"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Third Party Advisory"
            ],
            "url": "https://www.gov.il/en/Departments/faq/cve_advisories"
          }
        ],
        "sourceIdentifier": "cna@cyber.gov.il",
        "vulnStatus": "Modified",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-494"
              }
            ],
            "source": "cna@cyber.gov.il",
            "type": "Secondary"
          }
        ]
      }
    },
    "redhat_vex": {
      "current_release_date": "2025-05-29T00:33:21+00:00",
      "cve": "CVE-2023-37220",
      "id": "CVE-2023-37220",
      "initial_release_date": "2023-09-03T13:42:00+00:00",
      "product_status:known_not_affected": "1",
      "source": "Red Hat CSAF VEX",
      "status": "final",
      "title": "Synel Terminals - CWE-494: Download of Code Without Integrity Check",
      "url": "https://security.access.redhat.com/data/csaf/v2/vex/2023/cve-2023-37220.json",
      "version": "3"
    },
    "vulnrichment": {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T17:09:34.169Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.gov.il/en/Departments/faq/cve_advisories"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:synel:terminals:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "terminals",
                "vendor": "synel",
                "versions": [
                  {
                    "lessThan": "3015.1",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-37220",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-10-01T13:06:04.073013Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-10-01T13:07:20.312Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Terminals",
              "vendor": "Synel ",
              "versions": [
                {
                  "lessThan": "Upgrade to version 3015.1",
                  "status": "affected",
                  "version": "All versions",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Elad Ernst"
            }
          ],
          "datePublic": "2023-09-03T13:42:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eSynel Terminals - CWE-494: Download of Code Without Integrity Check\u003c/span\u003e\n\n"
                }
              ],
              "value": "\nSynel Terminals - CWE-494: Download of Code Without Integrity Check\n\n"
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 7.2,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "HIGH",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-494",
                  "description": "CWE-494 Download of Code Without Integrity Check",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-09-03T13:47:05.388Z",
            "orgId": "a57ee1ae-c9c1-4f40-aa7b-cf10760fde3f",
            "shortName": "INCD"
          },
          "references": [
            {
              "url": "https://www.gov.il/en/Departments/faq/cve_advisories"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eUpgrade to version 3015.1\u003c/span\u003e\n\n\u003cbr\u003e"
                }
              ],
              "value": "\nUpgrade to version 3015.1\n\n\n"
            }
          ],
          "source": {
            "advisory": "ILVN-2023-0122",
            "discovery": "UNKNOWN"
          },
          "title": "Synel Terminals - CWE-494: Download of Code Without Integrity Check",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "a57ee1ae-c9c1-4f40-aa7b-cf10760fde3f",
        "assignerShortName": "INCD",
        "cveId": "CVE-2023-37220",
        "datePublished": "2023-09-03T13:47:05.388Z",
        "dateReserved": "2023-06-28T20:35:37.792Z",
        "dateUpdated": "2024-10-01T13:07:25.275Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…