GCVE Workshop - 22 September 2026 (14:00-18:00), Luxembourg Before The Vulnopticon Conference - Registration

CVE-2021-31755 (GCVE-0-2021-31755)

Vulnerability from cvelistv5 – Published: 2021-05-07 22:01 – Updated: 2025-10-21 23:25
VLAI CISA Shadowserver Previdian
Summary
An issue was discovered on Tenda AC11 devices with firmware through 02.03.01.104_CN. A stack buffer overflow vulnerability in /goform/setmac allows attackers to execute arbitrary code on the system via a crafted post request.
SSVC
Exploitation: active Automatable: yes Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-02-04 19:44 UTC
CWE
  • n/a
  • CWE-787 - Out-of-bounds Write
References
Date Public
2021-04-24 00:00
CISA
Known Exploited Vulnerability - GCVE BCP-07 Compliant

Vulnerability ID: CVE-2021-31755

Status: Confirmed

Status Updated: 2021-11-03 00:00 UTC

Exploited: Yes


Timestamps
First Seen: 2021-11-03
Asserted: 2021-11-03

Scope
Notes: KEV entry: Tenda AC11 Router Stack Buffer Overflow Vulnerability | Affected: Tenda / AC11 Router | Description: Tenda AC11 devices contain a stack buffer overflow vulnerability in /goform/setmac which allows attackers to execute code via a crafted post request. | Required action: Apply updates per vendor instructions. | Due date: 2021-11-17 | Known ransomware campaign use (KEV): Unknown | Notes (KEV): https://nvd.nist.gov/vuln/detail/CVE-2021-31755

Evidence

Type: Vendor Report

Signal: Successful Exploitation

Confidence: 80%

Source: cisa-kev


Details
Cwes CWE-787
Feed CISA Known Exploited Vulnerabilities Catalog
Product AC11 Router
Due Date 2021-11-17
Date Added 2021-11-03
Vendorproject Tenda
Vulnerabilityname Tenda AC11 Router Stack Buffer Overflow Vulnerability
Knownransomwarecampaignuse Unknown

References

Created: 2026-02-02 13:26 UTC | Updated: 2026-02-06 07:53 UTC
Shadowserver
Known Exploited Vulnerability - GCVE BCP-07 Compliant

Vulnerability ID: CVE-2021-31755

Status: Confirmed

Status Updated: 2026-09-06 00:00 UTC

Exploited: Yes


Characteristics
Severity: 98.0

Timestamps
First Seen: 2023-10-14
Asserted: 2023-10-14
Last Seen: 2026-09-06

Scope
Asset Exposure: ['internet-facing']
Notes: Affected: Tenda / Tenda AC11 | Class: router | Severity: Critical (CVSS 9.8) | IoT: yes | In CISA KEV: yes | Honeypot connections on 2026-09-06: 43

Evidence

Type: Honeypot

Signal: In The Wild Attempts

Confidence: 70%

Source: shadowserver


Details
1D 3
Iot yes
Feed Shadowserver Foundation honeypot/exploited-vulnerabilities
Type http-scan
Class router
7D Avg 2
Vendor Tenda
30D Avg 3
90D Avg 3
Product Tenda AC11
Cisa Kev yes
Connections 43
Observation Date 2026-09-06
Vulnerability Class CVSS
Vulnerability Score 9.8
Vulnerability Severity Critical

References

Created: 2026-07-01 05:53 UTC | Updated: 2026-09-08 01:00 UTC
Previdian
Known Exploited Vulnerability - GCVE BCP-07 Compliant

Vulnerability ID: CVE-2021-31755

Status: Confirmed

Status Updated: 2021-11-03 00:00 UTC

Exploited: Yes


Timestamps
First Seen: 2021-11-03
Asserted: 2021-11-03

Scope
Notes: KEVIntel entry: An issue was discovered on Tenda AC11 devices with firmware through 02.03.01.104_CN. A stack buffer overflow vulnerability in /goform/setmac allows... | Affected: Tenda / AC11 | CVSS: 9.8 (CRITICAL) | EPSS: 0.85849 | Used in malware: unknown | Not yet in CISA KEV: False

Evidence

Type: Public Report

Signal: Successful Exploitation

Confidence: 70%

Source: kevintel


Details
Feed KEVIntel (kevintel.com)
Title An issue was discovered on Tenda AC11 devices with firmware through 02.03.01.104_CN. A stack buffer overflow vulnerability in /goform/setmac allows...
Vendor Tenda
Product AC11
Added Date 2021-11-03T00:00:00.000Z
Cvss Score 9.8
Epss Score 0.85849
Cvss Severity CRITICAL
Epss Percentile 0.99699
Used In Malware unknown
Ahead Of Cisa Kev None
Not Yet In Cisa Kev False

References

Created: 2026-06-23 11:13 UTC | Updated: 2026-06-23 11:13 UTC
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T23:03:33.780Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/Yu3H0/IoT_CVE/tree/main/Tenda/CVE_3"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2021-31755",
                "options": [
                  {
                    "Exploitation": "active"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-02-04T19:44:13.561933Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          },
          {
            "other": {
              "content": {
                "dateAdded": "2021-11-03",
                "reference": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2021-31755"
              },
              "type": "kev"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-787",
                "description": "CWE-787 Out-of-bounds Write",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-10-21T23:25:46.571Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "references": [
          {
            "tags": [
              "government-resource"
            ],
            "url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2021-31755"
          }
        ],
        "timeline": [
          {
            "lang": "en",
            "time": "2021-11-03T00:00:00.000Z",
            "value": "CVE-2021-31755 added to CISA KEV"
          }
        ],
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2021-04-24T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "An issue was discovered on Tenda AC11 devices with firmware through 02.03.01.104_CN. A stack buffer overflow vulnerability in /goform/setmac allows attackers to execute arbitrary code on the system via a crafted post request."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-05-07T22:01:44.000Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/Yu3H0/IoT_CVE/tree/main/Tenda/CVE_3"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2021-31755",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An issue was discovered on Tenda AC11 devices with firmware through 02.03.01.104_CN. A stack buffer overflow vulnerability in /goform/setmac allows attackers to execute arbitrary code on the system via a crafted post request."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/Yu3H0/IoT_CVE/tree/main/Tenda/CVE_3",
              "refsource": "MISC",
              "url": "https://github.com/Yu3H0/IoT_CVE/tree/main/Tenda/CVE_3"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2021-31755",
    "datePublished": "2021-05-07T22:01:44.000Z",
    "dateReserved": "2021-04-23T00:00:00.000Z",
    "dateUpdated": "2025-10-21T23:25:46.571Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "cisa_known_exploited": {
      "cveID": "CVE-2021-31755",
      "cwes": [
        "CWE-787"
      ],
      "dateAdded": "2021-11-03",
      "dueDate": "2021-11-17",
      "forensicTriage": "No",
      "knownRansomwareCampaignUse": "Unknown",
      "notes": "https://nvd.nist.gov/vuln/detail/CVE-2021-31755",
      "product": "AC11 Router",
      "requiredAction": "Apply updates per vendor instructions.",
      "shortDescription": "Tenda AC11 devices contain a stack buffer overflow vulnerability in /goform/setmac which allows attackers to execute code via a crafted post request.",
      "vendorProject": "Tenda",
      "vulnerabilityName": "Tenda AC11 Router Stack Buffer Overflow Vulnerability"
    },
    "epss": {
      "cve": "CVE-2021-31755",
      "date": "2026-09-20",
      "epss": "0.86891",
      "percentile": "0.99738"
    },
    "nvd": {
      "cve": {
        "cisaActionDue": "2021-11-17",
        "cisaExploitAdd": "2021-11-03",
        "cisaRequiredAction": "Apply updates per vendor instructions.",
        "cisaVulnerabilityName": "Tenda AC11 Router Stack Buffer Overflow Vulnerability",
        "configurations": [
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:tenda:ac11_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "08B4F9BE-9D0D-4297-A0EE-2B8D4853DD0E",
                    "versionEndIncluding": "02.03.01.104_cn",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:tenda:ac11:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "8850E87F-3B1D-4D24-8F22-B358B27EE582",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "An issue was discovered on Tenda AC11 devices with firmware through 02.03.01.104_CN. A stack buffer overflow vulnerability in /goform/setmac allows attackers to execute arbitrary code on the system via a crafted post request."
          },
          {
            "lang": "es",
            "value": "Se detect\u00f3 un problema en los dispositivos Tenda AC11 con firmware hasta 02.03.01.104_CN. Una vulnerabilidad de desbordamiento del b\u00fafer de la pila en /goform/setmac permite a los atacantes ejecutar c\u00f3digo arbitrario en el sistema a trav\u00e9s de una solicitud de correo manipulada"
          }
        ],
        "id": "CVE-2021-31755",
        "lastModified": "2025-11-10T14:42:36.837",
        "metrics": {
          "cvssMetricV2": [
            {
              "acInsufInfo": false,
              "baseSeverity": "HIGH",
              "cvssData": {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "availabilityImpact": "COMPLETE",
                "baseScore": 10.0,
                "confidentialityImpact": "COMPLETE",
                "integrityImpact": "COMPLETE",
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              },
              "exploitabilityScore": 10.0,
              "impactScore": 10.0,
              "obtainAllPrivilege": false,
              "obtainOtherPrivilege": false,
              "obtainUserPrivilege": false,
              "source": "nvd@nist.gov",
              "type": "Primary",
              "userInteractionRequired": false
            }
          ],
          "cvssMetricV31": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "exploitabilityScore": 3.9,
              "impactScore": 5.9,
              "source": "nvd@nist.gov",
              "type": "Primary"
            },
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "exploitabilityScore": 3.9,
              "impactScore": 5.9,
              "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "type": "Secondary"
            }
          ]
        },
        "published": "2021-05-07T23:15:07.047",
        "references": [
          {
            "source": "cve@mitre.org",
            "tags": [
              "Broken Link",
              "Exploit",
              "Issue Tracking",
              "Third Party Advisory"
            ],
            "url": "https://github.com/Yu3H0/IoT_CVE/tree/main/Tenda/CVE_3"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Broken Link",
              "Exploit",
              "Issue Tracking",
              "Third Party Advisory"
            ],
            "url": "https://github.com/Yu3H0/IoT_CVE/tree/main/Tenda/CVE_3"
          },
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "tags": [
              "US Government Resource"
            ],
            "url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2021-31755"
          }
        ],
        "sourceIdentifier": "cve@mitre.org",
        "vulnStatus": "Analyzed",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-787"
              }
            ],
            "source": "nvd@nist.gov",
            "type": "Primary"
          },
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-787"
              }
            ],
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "type": "Secondary"
          }
        ]
      }
    },
    "redhat_vex": {
      "current_release_date": "2026-03-27T14:06:39+00:00",
      "cve": "CVE-2021-31755",
      "id": "CVE-2021-31755",
      "initial_release_date": "2021-04-24T00:00:00+00:00",
      "product_status:known_not_affected": "1",
      "source": "Red Hat CSAF VEX",
      "status": "final",
      "title": "CVE-2021-31755",
      "url": "https://security.access.redhat.com/data/csaf/v2/vex/2021/cve-2021-31755.json",
      "version": "3"
    },
    "vulnrichment": {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T23:03:33.780Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://github.com/Yu3H0/IoT_CVE/tree/main/Tenda/CVE_3"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 9.8,
                  "baseSeverity": "CRITICAL",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2021-31755",
                    "options": [
                      {
                        "Exploitation": "active"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-02-04T19:44:13.561933Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              },
              {
                "other": {
                  "content": {
                    "dateAdded": "2021-11-03",
                    "reference": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2021-31755"
                  },
                  "type": "kev"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-787",
                    "description": "CWE-787 Out-of-bounds Write",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-02-04T19:43:54.978Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "references": [
              {
                "tags": [
                  "government-resource"
                ],
                "url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2021-31755"
              }
            ],
            "timeline": [
              {
                "lang": "en",
                "time": "2021-11-03T00:00:00.000Z",
                "value": "CVE-2021-31755 added to CISA KEV"
              }
            ],
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2021-04-24T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "An issue was discovered on Tenda AC11 devices with firmware through 02.03.01.104_CN. A stack buffer overflow vulnerability in /goform/setmac allows attackers to execute arbitrary code on the system via a crafted post request."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2021-05-07T22:01:44.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://github.com/Yu3H0/IoT_CVE/tree/main/Tenda/CVE_3"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2021-31755",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "An issue was discovered on Tenda AC11 devices with firmware through 02.03.01.104_CN. A stack buffer overflow vulnerability in /goform/setmac allows attackers to execute arbitrary code on the system via a crafted post request."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://github.com/Yu3H0/IoT_CVE/tree/main/Tenda/CVE_3",
                  "refsource": "MISC",
                  "url": "https://github.com/Yu3H0/IoT_CVE/tree/main/Tenda/CVE_3"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2021-31755",
        "datePublished": "2021-05-07T22:01:44.000Z",
        "dateReserved": "2021-04-23T00:00:00.000Z",
        "dateUpdated": "2025-10-21T23:25:46.571Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…