CVE-2019-20466 (GCVE-0-2019-20466)

Vulnerability from cvelistv5 – Published: 2021-04-02 15:37 – Updated: 2024-08-05 02:39
VLAI
Summary
An issue was discovered on Sannce Smart HD Wifi Security Camera EAN 2 950004 595317 devices. A local attacker with the "default" account is capable of reading the /etc/passwd file, which contains a weakly hashed root password. By taking this hash and cracking it, the attacker can obtain root rights on the device.
SSVC
Exploitation: none Automatable: no Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-07-30 13:53 UTC
CWE
  • n/a
  • CWE-916 - Use of Password Hash With Insufficient Computational Effort
Impacted products
Vendor Product Version CPE status
sannce smart_hd_wifi_security_camera_ean_2_950004_595317_firmware Affected: 0 , < * (custom)
    cpe:2.3:h:sannce:smart_hd_wifi_security_camera_ean_2_950004_595317:-:*:*:*:*:*:*:*
    cpe:2.3:o:sannce:smart_hd_wifi_security_camera_ean_2_950004_595317_firmware:-:*:*:*:*:*:*:*
Create a notification for this product.
Date Public
2021-03-30 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:h:sannce:smart_hd_wifi_security_camera_ean_2_950004_595317:-:*:*:*:*:*:*:*",
              "cpe:2.3:o:sannce:smart_hd_wifi_security_camera_ean_2_950004_595317_firmware:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "smart_hd_wifi_security_camera_ean_2_950004_595317_firmware",
            "vendor": "sannce",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "LOCAL",
              "availabilityImpact": "HIGH",
              "baseScore": 7.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "LOW",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2019-20466",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-07-30T13:53:31.700735Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-916",
                "description": "CWE-916 Use of Password Hash With Insufficient Computational Effort",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-30T13:58:43.651Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T02:39:09.901Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.eurofins-cybersecurity.com/news/connected-devices-baby-monitors-part-2/"
          },
          {
            "name": "20240729 Bunch of IoT CVEs",
            "tags": [
              "mailing-list",
              "x_transferred"
            ],
            "url": "http://seclists.org/fulldisclosure/2024/Jul/14"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2021-03-30T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "An issue was discovered on Sannce Smart HD Wifi Security Camera EAN 2 950004 595317 devices. A local attacker with the \"default\" account is capable of reading the /etc/passwd file, which contains a weakly hashed root password. By taking this hash and cracking it, the attacker can obtain root rights on the device."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-07-30T00:07:40.792Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://www.eurofins-cybersecurity.com/news/connected-devices-baby-monitors-part-2/"
        },
        {
          "name": "20240729 Bunch of IoT CVEs",
          "tags": [
            "mailing-list"
          ],
          "url": "http://seclists.org/fulldisclosure/2024/Jul/14"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2019-20466",
    "datePublished": "2021-04-02T15:37:05.000Z",
    "dateReserved": "2020-02-17T00:00:00.000Z",
    "dateUpdated": "2024-08-05T02:39:09.901Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2019-20466",
      "date": "2026-09-20",
      "epss": "0.00346",
      "percentile": "0.28212"
    },
    "nvd": {
      "cve": {
        "configurations": [
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:sannce:smart_hd_wifi_security_camera_ean_2_950004_595317_firmware:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "8123D4F3-B94B-405B-9FF5-0CA27A0B719E",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:sannce:smart_hd_wifi_security_camera_ean_2_950004_595317:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "548EDA0C-3BBF-44AF-99DC-73796B27874D",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "An issue was discovered on Sannce Smart HD Wifi Security Camera EAN 2 950004 595317 devices. A local attacker with the \"default\" account is capable of reading the /etc/passwd file, which contains a weakly hashed root password. By taking this hash and cracking it, the attacker can obtain root rights on the device."
          },
          {
            "lang": "es",
            "value": "Se detect\u00f3 un problema en los dispositivos Sannce Smart HD Wifi Security Camera EAN 2 950004 595317.\u0026#xa0;Un atacante local con la cuenta \"default\" es capaz de leer el archivo /etc/passwd, que contiene una contrase\u00f1a de root con un hash d\u00e9bil.\u0026#xa0;Al tomar este hash y descifrarlo, el atacante puede obtener derechos de root en el dispositivo."
          }
        ],
        "id": "CVE-2019-20466",
        "lastModified": "2024-11-21T04:38:32.987",
        "metrics": {
          "cvssMetricV2": [
            {
              "acInsufInfo": false,
              "baseSeverity": "HIGH",
              "cvssData": {
                "accessComplexity": "LOW",
                "accessVector": "LOCAL",
                "authentication": "NONE",
                "availabilityImpact": "COMPLETE",
                "baseScore": 7.2,
                "confidentialityImpact": "COMPLETE",
                "integrityImpact": "COMPLETE",
                "vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              },
              "exploitabilityScore": 3.9,
              "impactScore": 10.0,
              "obtainAllPrivilege": false,
              "obtainOtherPrivilege": false,
              "obtainUserPrivilege": false,
              "source": "nvd@nist.gov",
              "type": "Primary",
              "userInteractionRequired": false
            }
          ],
          "cvssMetricV31": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "exploitabilityScore": 1.8,
              "impactScore": 5.9,
              "source": "nvd@nist.gov",
              "type": "Primary"
            },
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "exploitabilityScore": 1.8,
              "impactScore": 5.9,
              "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "type": "Secondary"
            }
          ]
        },
        "published": "2021-04-02T16:15:13.193",
        "references": [
          {
            "source": "cve@mitre.org",
            "url": "http://seclists.org/fulldisclosure/2024/Jul/14"
          },
          {
            "source": "cve@mitre.org",
            "tags": [
              "Exploit",
              "Third Party Advisory"
            ],
            "url": "https://www.eurofins-cybersecurity.com/news/connected-devices-baby-monitors-part-2/"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "url": "http://seclists.org/fulldisclosure/2024/Jul/14"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Exploit",
              "Third Party Advisory"
            ],
            "url": "https://www.eurofins-cybersecurity.com/news/connected-devices-baby-monitors-part-2/"
          }
        ],
        "sourceIdentifier": "cve@mitre.org",
        "vulnStatus": "Modified",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-916"
              }
            ],
            "source": "nvd@nist.gov",
            "type": "Primary"
          },
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-916"
              }
            ],
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "type": "Secondary"
          }
        ]
      }
    },
    "vulnrichment": {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T02:39:09.901Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.eurofins-cybersecurity.com/news/connected-devices-baby-monitors-part-2/"
              },
              {
                "name": "20240729 Bunch of IoT CVEs",
                "tags": [
                  "mailing-list",
                  "x_transferred"
                ],
                "url": "http://seclists.org/fulldisclosure/2024/Jul/14"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:h:sannce:smart_hd_wifi_security_camera_ean_2_950004_595317:-:*:*:*:*:*:*:*",
                  "cpe:2.3:o:sannce:smart_hd_wifi_security_camera_ean_2_950004_595317_firmware:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "smart_hd_wifi_security_camera_ean_2_950004_595317_firmware",
                "vendor": "sannce",
                "versions": [
                  {
                    "lessThan": "*",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "LOCAL",
                  "availabilityImpact": "HIGH",
                  "baseScore": 7.8,
                  "baseSeverity": "HIGH",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "LOW",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2019-20466",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-07-30T13:53:31.700735Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-916",
                    "description": "CWE-916 Use of Password Hash With Insufficient Computational Effort",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-07-30T13:55:12.800Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2021-03-30T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "An issue was discovered on Sannce Smart HD Wifi Security Camera EAN 2 950004 595317 devices. A local attacker with the \"default\" account is capable of reading the /etc/passwd file, which contains a weakly hashed root password. By taking this hash and cracking it, the attacker can obtain root rights on the device."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-07-30T00:07:40.792Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://www.eurofins-cybersecurity.com/news/connected-devices-baby-monitors-part-2/"
            },
            {
              "name": "20240729 Bunch of IoT CVEs",
              "tags": [
                "mailing-list"
              ],
              "url": "http://seclists.org/fulldisclosure/2024/Jul/14"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2019-20466",
        "datePublished": "2021-04-02T15:37:05.000Z",
        "dateReserved": "2020-02-17T00:00:00.000Z",
        "dateUpdated": "2024-08-05T02:39:09.901Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…