VDE-2025-014
Vulnerability from csaf_phoenixcontactgmbhcokg - Published: 2025-07-08 10:00 - Updated: 2025-07-08 10:00Summary
Phoenix Contact: Security Advisory for CHARX SEC-3xxx charging controllers
Severity
High
Notes
Summary: Multiple vulnerabilities in the firmware of CHARX SEC-3xxx charging controllers have been discovered.
Impact: The vulnerabilities can lead to a total loss of confidentiality, integrity and availability of the devices.
Mitigation: Affected charging controllers are designed and developed for the use in closed industrial networks. Phoenix Contact therefore strongly recommends using the devices exclusively in closed networks and protected by a suitable firewall.
Remediation: Phoenix Contact strongly recommends to upgrade to firmware version 1.7.3 which fixes vulnerabilities CVE-2025-24005 and CVE-2025-24006. The vulnerabilities CVE-2025-24002, CVE-2025-24003 and CVE-2025-24004 affect the Eichrecht functionality in FW <=1.6.5 and in the meantime there is no vendor fix planned for these issues.
General Recommendation: For general information and recommendations on security measures to protect network-enabled devices, refer to the application note: [Application Note Security](https://dam-mdc.phoenixcontact.com/asset/156443151564/0a870ae433c19148b80bd760f3a1c1f2/107913_en_03.pdf).
Product Description: CHARX SEC EVSE charging controller
5.3 (Medium)
Mitigation
This product was designed for use in closed industrial networks. Phoenix Contact strongly recommends operating network-capable devices in closed networks or protected with a suitable firewall. For detailed information on our recommendations for measures to protect network-capable devices, please refer to our [application note](https://dam-mdc.phoenixcontact.com/asset/156443151564/0a870ae433c19148b80bd760f3a1c1f2/107913_en_03.pdf).
Affected products
Known affected
4 products
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-31005 | — | ||
| Unresolved product id: CSAFPID-31006 | — | ||
| Unresolved product id: CSAFPID-31007 | — | ||
| Unresolved product id: CSAFPID-31008 | — |
8.2 (High)
Mitigation
This product was designed for use in closed industrial networks. Phoenix Contact strongly recommends operating network-capable devices in closed networks or protected with a suitable firewall. For detailed information on our recommendations for measures to protect network-capable devices, please refer to our [application note](https://dam-mdc.phoenixcontact.com/asset/156443151564/0a870ae433c19148b80bd760f3a1c1f2/107913_en_03.pdf).
Affected products
Known affected
4 products
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-31005 | — | ||
| Unresolved product id: CSAFPID-31006 | — | ||
| Unresolved product id: CSAFPID-31007 | — | ||
| Unresolved product id: CSAFPID-31008 | — |
5.2 (Medium)
Mitigation
This product was designed for use in closed industrial networks. Phoenix Contact strongly recommends operating network-capable devices in closed networks or protected with a suitable firewall. For detailed information on our recommendations for measures to protect network-capable devices, please refer to our [application note](https://dam-mdc.phoenixcontact.com/asset/156443151564/0a870ae433c19148b80bd760f3a1c1f2/107913_en_03.pdf).
Affected products
Known affected
4 products
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-31005 | — | ||
| Unresolved product id: CSAFPID-31006 | — | ||
| Unresolved product id: CSAFPID-31007 | — | ||
| Unresolved product id: CSAFPID-31008 | — |
7.8 (High)
Mitigation
This product was designed for use in closed industrial networks. Phoenix Contact strongly recommends operating network-capable devices in closed networks or protected with a suitable firewall. For detailed information on our recommendations for measures to protect network-capable devices, please refer to our [application note](https://dam-mdc.phoenixcontact.com/asset/156443151564/0a870ae433c19148b80bd760f3a1c1f2/107913_en_03.pdf).
Vendor Fix
Phoenix Contact strongly recommends to upgrade to firmware version 1.7.3 which fixes vulnerabilities CVE-2025-24005 and CVE-2025-24006. The vulnerabilities CVE-2025-24002, CVE-2025-24003 and CVE-2025-24004 affect the Eichrecht functionality and in the meantime there is no vendor fix planned for these issues..
Affected products
Fixed
4 products
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-32001 | — | ||
| Unresolved product id: CSAFPID-32002 | — | ||
| Unresolved product id: CSAFPID-32003 | — | ||
| Unresolved product id: CSAFPID-32004 | — |
Known affected
4 products
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-31001 | — | ||
| Unresolved product id: CSAFPID-31002 | — | ||
| Unresolved product id: CSAFPID-31003 | — | ||
| Unresolved product id: CSAFPID-31004 | — |
7.8 (High)
Mitigation
This product was designed for use in closed industrial networks. Phoenix Contact strongly recommends operating network-capable devices in closed networks or protected with a suitable firewall. For detailed information on our recommendations for measures to protect network-capable devices, please refer to our [application note](https://dam-mdc.phoenixcontact.com/asset/156443151564/0a870ae433c19148b80bd760f3a1c1f2/107913_en_03.pdf).
Vendor Fix
Phoenix Contact strongly recommends to upgrade to firmware version 1.7.3 which fixes vulnerabilities CVE-2025-24005 and CVE-2025-24006. The vulnerabilities CVE-2025-24002, CVE-2025-24003 and CVE-2025-24004 affect the Eichrecht functionality and in the meantime there is no vendor fix planned for these issues.
Affected products
Fixed
4 products
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-32001 | — | ||
| Unresolved product id: CSAFPID-32002 | — | ||
| Unresolved product id: CSAFPID-32003 | — | ||
| Unresolved product id: CSAFPID-32004 | — |
Known affected
4 products
| Product | Identifier | Version | Remediation |
|---|---|---|---|
| Unresolved product id: CSAFPID-31001 | — | ||
| Unresolved product id: CSAFPID-31002 | — | ||
| Unresolved product id: CSAFPID-31003 | — | ||
| Unresolved product id: CSAFPID-31004 | — |
References
5 references
Acknowledgments
CERTVDE
certvde.com/en/
ivision
Jesson Soto Ventura
Matthew Waddell
ivision
Jesson Soto Ventura
Matthew Waddell
{
"document": {
"acknowledgments": [
{
"organization": "CERTVDE",
"summary": "coordination.",
"urls": [
"https://certvde.com/en/"
]
},
{
"names": [
"Jesson Soto Ventura",
"Matthew Waddell"
],
"organization": "ivision",
"summary": "reporting."
}
],
"aggregate_severity": {
"namespace": "https://www.first.org/cvss/v3.1/specification-document#Qualitative-Severity-Rating-Scale",
"text": "High"
},
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"tlp": {
"label": "WHITE",
"url": "https://www.first.org/tlp/"
}
},
"lang": "en-GB",
"notes": [
{
"category": "summary",
"text": "Multiple vulnerabilities in the firmware of CHARX SEC-3xxx charging controllers have been discovered.",
"title": "Summary"
},
{
"category": "description",
"text": "The vulnerabilities can lead to a total loss of confidentiality, integrity and availability of the devices.",
"title": "Impact"
},
{
"category": "description",
"text": "Affected charging controllers are designed and developed for the use in closed industrial networks. Phoenix Contact therefore strongly recommends using the devices exclusively in closed networks and protected by a suitable firewall.",
"title": "Mitigation"
},
{
"category": "description",
"text": "Phoenix Contact strongly recommends to upgrade to firmware version 1.7.3 which fixes vulnerabilities CVE-2025-24005 and CVE-2025-24006. The vulnerabilities CVE-2025-24002, CVE-2025-24003 and CVE-2025-24004 affect the Eichrecht functionality in FW \u003c=1.6.5 and in the meantime there is no vendor fix planned for these issues.",
"title": "Remediation"
},
{
"category": "general",
"text": "For general information and recommendations on security measures to protect network-enabled devices, refer to the application note: [Application Note Security](https://dam-mdc.phoenixcontact.com/asset/156443151564/0a870ae433c19148b80bd760f3a1c1f2/107913_en_03.pdf).",
"title": "General Recommendation"
},
{
"category": "description",
"text": "CHARX SEC EVSE charging controller",
"title": "Product Description"
}
],
"publisher": {
"category": "vendor",
"contact_details": "psirt@phoenixcontact.com",
"name": "Phoenix Contact GmbH \u0026 Co. KG",
"namespace": "https://phoenixcontact.com/psirt"
},
"references": [
{
"category": "external",
"summary": "PCSA-2025-00001",
"url": "https://phoenixcontact.com/psirt"
},
{
"category": "external",
"summary": "Phoenix Contact advisory overview at CERT@VDE",
"url": "https://certvde.com/de/advisories/vendor/phoenixcontact/"
},
{
"category": "self",
"summary": "VDE-2025-014: Phoenix Contact: Security Advisory for CHARX SEC-3xxx charging controllers - HTML",
"url": "https://certvde.com/en/advisories/VDE-2025-014"
},
{
"category": "self",
"summary": "VDE-2025-014: Phoenix Contact: Security Advisory for CHARX SEC-3xxx charging controllers - CSAF",
"url": "https://phoenixcontact.csaf-tp.certvde.com/.well-known/csaf/white/2025/vde-2025-014.json"
},
{
"category": "external",
"summary": "Phoenix Contact application note",
"url": "https://dam-mdc.phoenixcontact.com/asset/156443151564/0a870ae433c19148b80bd760f3a1c1f2/107913_en_03.pdf"
}
],
"title": "Phoenix Contact: Security Advisory for CHARX SEC-3xxx charging controllers",
"tracking": {
"aliases": [
"VDE-2025-014",
"PCSA-2025-00001"
],
"current_release_date": "2025-07-08T10:00:00.000Z",
"generator": {
"date": "2025-07-01T07:46:11.590Z",
"engine": {
"name": "Secvisogram",
"version": "2.5.27"
}
},
"id": "VDE-2025-014",
"initial_release_date": "2025-07-08T10:00:00.000Z",
"revision_history": [
{
"date": "2025-07-08T10:00:00.000Z",
"number": "1",
"summary": "Initial Revision"
}
],
"status": "final",
"version": "1"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_name",
"name": "CHARX SEC-3150",
"product": {
"name": "CHARX SEC-3150",
"product_id": "CSAFPID-11001"
}
},
{
"category": "product_name",
"name": "CHARX SEC-3100",
"product": {
"name": "CHARX SEC-3150",
"product_id": "CSAFPID-11002"
}
},
{
"category": "product_name",
"name": "CHARX SEC-3050",
"product": {
"name": "CHARX SEC-3050",
"product_id": "CSAFPID-11003"
}
},
{
"category": "product_name",
"name": "CHARX SEC-3000",
"product": {
"name": "CHARX SEC-3000",
"product_id": "CSAFPID-11004"
}
}
],
"category": "product_family",
"name": "Hardware"
},
{
"branches": [
{
"category": "product_version_range",
"name": "\u003cFW 1.7.3",
"product": {
"name": "Firmware \u003c FW 1.7.3",
"product_id": "CSAFPID-21001"
}
},
{
"category": "product_version",
"name": "FW 1.7.3",
"product": {
"name": "Firmware 1.7.3",
"product_id": "CSAFPID-22001"
}
},
{
"category": "product_version_range",
"name": "\u003c=FW 1.6.5",
"product": {
"name": "Firmware \u003c= FW 1.6.5",
"product_id": "CSAFPID-21002"
}
}
],
"category": "product_family",
"name": "Firmware"
}
],
"category": "vendor",
"name": "Phoenix Contact"
}
],
"product_groups": [
{
"group_id": "CSAFGID-0001",
"product_ids": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004",
"CSAFPID-31005",
"CSAFPID-31006",
"CSAFPID-31007",
"CSAFPID-31008"
],
"summary": "Affected products."
},
{
"group_id": "CSAFGID-0002",
"product_ids": [
"CSAFPID-32001",
"CSAFPID-32002",
"CSAFPID-32003",
"CSAFPID-32004"
],
"summary": "Fixed products."
}
],
"relationships": [
{
"category": "installed_on",
"full_product_name": {
"name": "FW \u003c1.7.3 installed on CHARX SEC-3150",
"product_id": "CSAFPID-31001"
},
"product_reference": "CSAFPID-21001",
"relates_to_product_reference": "CSAFPID-11001"
},
{
"category": "installed_on",
"full_product_name": {
"name": "FW \u003c1.7.3 installed on CHARX SEC-3100",
"product_id": "CSAFPID-31002"
},
"product_reference": "CSAFPID-21001",
"relates_to_product_reference": "CSAFPID-11002"
},
{
"category": "installed_on",
"full_product_name": {
"name": "FW \u003c1.7.3 installed on CHARX SEC-3050",
"product_id": "CSAFPID-31003"
},
"product_reference": "CSAFPID-21001",
"relates_to_product_reference": "CSAFPID-11003"
},
{
"category": "installed_on",
"full_product_name": {
"name": "FW \u003c1.7.3 installed on CHARX SEC-3000",
"product_id": "CSAFPID-31004"
},
"product_reference": "CSAFPID-21001",
"relates_to_product_reference": "CSAFPID-11004"
},
{
"category": "installed_on",
"full_product_name": {
"name": "FW 1.7.3 installed on CHARX SEC-3150",
"product_id": "CSAFPID-32001"
},
"product_reference": "CSAFPID-22001",
"relates_to_product_reference": "CSAFPID-11001"
},
{
"category": "installed_on",
"full_product_name": {
"name": "FW 1.7.3 installed on CHARX SEC-3100",
"product_id": "CSAFPID-32002"
},
"product_reference": "CSAFPID-22001",
"relates_to_product_reference": "CSAFPID-11002"
},
{
"category": "installed_on",
"full_product_name": {
"name": "FW 1.7.3 installed on CHARX SEC-3050",
"product_id": "CSAFPID-32003"
},
"product_reference": "CSAFPID-22001",
"relates_to_product_reference": "CSAFPID-11003"
},
{
"category": "installed_on",
"full_product_name": {
"name": "FW 1.7.3 installed on CHARX SEC-3000",
"product_id": "CSAFPID-32004"
},
"product_reference": "CSAFPID-22001",
"relates_to_product_reference": "CSAFPID-11004"
},
{
"category": "installed_on",
"full_product_name": {
"name": "FW \u003c=1.6.5 installed on CHARX SEC-3150",
"product_id": "CSAFPID-31005"
},
"product_reference": "CSAFPID-21002",
"relates_to_product_reference": "CSAFPID-11001"
},
{
"category": "installed_on",
"full_product_name": {
"name": "FW \u003c=1.6.5 installed on CHARX SEC-3100",
"product_id": "CSAFPID-31006"
},
"product_reference": "CSAFPID-21002",
"relates_to_product_reference": "CSAFPID-11002"
},
{
"category": "installed_on",
"full_product_name": {
"name": "FW \u003c=1.6.5 installed on CHARX SEC-3050",
"product_id": "CSAFPID-31007"
},
"product_reference": "CSAFPID-21002",
"relates_to_product_reference": "CSAFPID-11003"
},
{
"category": "installed_on",
"full_product_name": {
"name": "FW \u003c=1.6.5 installed on CHARX SEC-3000",
"product_id": "CSAFPID-31008"
},
"product_reference": "CSAFPID-21002",
"relates_to_product_reference": "CSAFPID-11004"
}
]
},
"vulnerabilities": [
{
"acknowledgments": [
{
"names": [
"Jesson Soto Ventura",
"Matthew Waddell"
],
"organization": "ivision",
"summary": "reporting."
}
],
"cve": "CVE-2025-24002",
"cwe": {
"id": "CWE-20",
"name": "Improper Input Validation"
},
"notes": [
{
"category": "summary",
"text": "An unauthenticated remote attacker can use MQTT messages to crash a service on charging stations complying with German Calibration Law, resulting in a temporary denial-of-service for these stations until they got restarted by the watchdog.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-31005",
"CSAFPID-31006",
"CSAFPID-31007",
"CSAFPID-31008"
]
},
"remediations": [
{
"category": "mitigation",
"details": "This product was designed for use in closed industrial networks. Phoenix Contact strongly recommends operating network-capable devices in closed networks or protected with a suitable firewall. For detailed information on our recommendations for measures to protect network-capable devices, please refer to our [application note](https://dam-mdc.phoenixcontact.com/asset/156443151564/0a870ae433c19148b80bd760f3a1c1f2/107913_en_03.pdf). ",
"group_ids": [
"CSAFGID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"environmentalScore": 5.3,
"environmentalSeverity": "MEDIUM",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 5.3,
"temporalSeverity": "MEDIUM",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
"version": "3.1"
},
"products": [
"CSAFPID-31005",
"CSAFPID-31006",
"CSAFPID-31007",
"CSAFPID-31008"
]
}
],
"title": "CVE-2025-24002"
},
{
"acknowledgments": [
{
"names": [
"Jesson Soto Ventura",
"Matthew Waddell"
],
"organization": "ivision",
"summary": "reporting."
}
],
"cve": "CVE-2025-24003",
"cwe": {
"id": "CWE-120",
"name": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)"
},
"notes": [
{
"category": "summary",
"text": "An unauthenticated remote attacker can use MQTT messages to trigger out-of-bounds writes in charging stations complying with German Calibration Law, resulting in a loss of integrity for only EichrechtAgents and potential denial-of-service for these stations.\n\n",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-31005",
"CSAFPID-31006",
"CSAFPID-31007",
"CSAFPID-31008"
]
},
"remediations": [
{
"category": "mitigation",
"date": "2025-06-03T10:00:00.000Z",
"details": "This product was designed for use in closed industrial networks. Phoenix Contact strongly recommends operating network-capable devices in closed networks or protected with a suitable firewall. For detailed information on our recommendations for measures to protect network-capable devices, please refer to our [application note](https://dam-mdc.phoenixcontact.com/asset/156443151564/0a870ae433c19148b80bd760f3a1c1f2/107913_en_03.pdf). ",
"group_ids": [
"CSAFGID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"environmentalScore": 8.2,
"environmentalSeverity": "HIGH",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 8.2,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-31005",
"CSAFPID-31006",
"CSAFPID-31007",
"CSAFPID-31008"
]
}
],
"title": "CVE-2025-24003"
},
{
"acknowledgments": [
{
"names": [
"Jesson Soto Ventura",
"Matthew Waddell"
],
"organization": "ivision",
"summary": "reporting."
}
],
"cve": "CVE-2025-24004",
"cwe": {
"id": "CWE-120",
"name": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)"
},
"notes": [
{
"category": "summary",
"text": "A physical attacker with access to the device display via USB-C can send a message to the device which triggers an unsecure copy to a buffer resulting in loss of integrity and a temporary denial-of-service for the stations until they got restarted by the watchdog.\n\n",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-31005",
"CSAFPID-31006",
"CSAFPID-31007",
"CSAFPID-31008"
]
},
"remediations": [
{
"category": "mitigation",
"date": "2025-06-03T10:00:00.000Z",
"details": "This product was designed for use in closed industrial networks. Phoenix Contact strongly recommends operating network-capable devices in closed networks or protected with a suitable firewall. For detailed information on our recommendations for measures to protect network-capable devices, please refer to our [application note](https://dam-mdc.phoenixcontact.com/asset/156443151564/0a870ae433c19148b80bd760f3a1c1f2/107913_en_03.pdf). ",
"group_ids": [
"CSAFGID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "PHYSICAL",
"availabilityImpact": "LOW",
"baseScore": 5.2,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"environmentalScore": 5.2,
"environmentalSeverity": "MEDIUM",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"temporalScore": 5.2,
"temporalSeverity": "MEDIUM",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:L",
"version": "3.1"
},
"products": [
"CSAFPID-31005",
"CSAFPID-31006",
"CSAFPID-31007",
"CSAFPID-31008"
]
}
],
"title": "CVE-2025-24004"
},
{
"acknowledgments": [
{
"names": [
"Jesson Soto Ventura",
"Matthew Waddell"
],
"organization": "ivision",
"summary": "reporting."
}
],
"cve": "CVE-2025-24005",
"cwe": {
"id": "CWE-20",
"name": "Improper Input Validation"
},
"notes": [
{
"category": "summary",
"text": "A local attacker with a local user account can leverage a vulnerable script via SSH to escalate privileges to root due to improper input validation.",
"title": "Summary"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001",
"CSAFPID-32002",
"CSAFPID-32003",
"CSAFPID-32004"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"date": "2025-06-03T10:00:00.000Z",
"details": "This product was designed for use in closed industrial networks. Phoenix Contact strongly recommends operating network-capable devices in closed networks or protected with a suitable firewall. For detailed information on our recommendations for measures to protect network-capable devices, please refer to our [application note](https://dam-mdc.phoenixcontact.com/asset/156443151564/0a870ae433c19148b80bd760f3a1c1f2/107913_en_03.pdf). ",
"group_ids": [
"CSAFGID-0001"
]
},
{
"category": "vendor_fix",
"date": "2025-06-03T10:00:00.000Z",
"details": "Phoenix Contact strongly recommends to upgrade to firmware version 1.7.3 which fixes vulnerabilities CVE-2025-24005 and CVE-2025-24006. The vulnerabilities CVE-2025-24002, CVE-2025-24003 and CVE-2025-24004 affect the Eichrecht functionality and in the meantime there is no vendor fix planned for these issues..",
"group_ids": [
"CSAFGID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 7.8,
"environmentalSeverity": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 7.8,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2025-24005"
},
{
"acknowledgments": [
{
"names": [
"Jesson Soto Ventura",
"Matthew Waddell"
],
"organization": "ivision",
"summary": "reporting."
}
],
"cve": "CVE-2025-24006",
"cwe": {
"id": "CWE-269",
"name": "Improper Privilege Management"
},
"notes": [
{
"category": "summary",
"text": "A low privileged local attacker can leverage insecure permissions via SSH on the affected devices to escalate privileges to root.\n",
"title": "Summary"
}
],
"product_status": {
"fixed": [
"CSAFPID-32001",
"CSAFPID-32002",
"CSAFPID-32003",
"CSAFPID-32004"
],
"known_affected": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
},
"remediations": [
{
"category": "mitigation",
"date": "2025-06-03T10:00:00.000Z",
"details": "This product was designed for use in closed industrial networks. Phoenix Contact strongly recommends operating network-capable devices in closed networks or protected with a suitable firewall. For detailed information on our recommendations for measures to protect network-capable devices, please refer to our [application note](https://dam-mdc.phoenixcontact.com/asset/156443151564/0a870ae433c19148b80bd760f3a1c1f2/107913_en_03.pdf). ",
"group_ids": [
"CSAFGID-0001"
]
},
{
"category": "vendor_fix",
"date": "2025-06-03T10:00:00.000Z",
"details": "Phoenix Contact strongly recommends to upgrade to firmware version 1.7.3 which fixes vulnerabilities CVE-2025-24005 and CVE-2025-24006. The vulnerabilities CVE-2025-24002, CVE-2025-24003 and CVE-2025-24004 affect the Eichrecht functionality and in the meantime there is no vendor fix planned for these issues.",
"group_ids": [
"CSAFGID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"environmentalScore": 7.8,
"environmentalSeverity": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"temporalScore": 7.8,
"temporalSeverity": "HIGH",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"products": [
"CSAFPID-31001",
"CSAFPID-31002",
"CSAFPID-31003",
"CSAFPID-31004"
]
}
],
"title": "CVE-2025-24006"
}
]
}
Loading…
Loading…
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…