VAR-202511-1324
Vulnerability from variot - Updated: 2025-11-22 23:11A local stack-based buffer overflow vulnerability exists in the infostat.cgi and cstecgi.cgi binaries of ToToLink routers (A720R V4.1.5cu.614_B20230630, LR1200GB V9.1.0u.6619_B20230130, and NR1800X V9.1.0u.6681_B20230703). Both programs parse the contents of /proc/net/arp using sscanf() with "%s" format specifiers into fixed-size stack buffers without length validation. Specifically, one function writes user-controlled data into a single-byte buffer, and the other into adjacent small arrays without bounds checking. An attacker who controls the contents of /proc/net/arp can trigger memory corruption, leading to denial of service or potential arbitrary code execution
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202511-1324",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "a720r",
"scope": "eq",
"trust": 1.0,
"vendor": "totolink",
"version": "4.1.5cu.614_b20230630"
},
{
"model": "lr1200gb",
"scope": "eq",
"trust": 1.0,
"vendor": "totolink",
"version": "9.1.0u.6619_b20230130"
},
{
"model": "nr1800x",
"scope": "eq",
"trust": 1.0,
"vendor": "totolink",
"version": "9.1.0u.6681_b20230703"
},
{
"model": "a720r",
"scope": null,
"trust": 0.8,
"vendor": "totolink",
"version": null
},
{
"model": "lr1200gb",
"scope": null,
"trust": 0.8,
"vendor": "totolink",
"version": null
},
{
"model": "nr1800x",
"scope": null,
"trust": 0.8,
"vendor": "totolink",
"version": null
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2025-019636"
},
{
"db": "NVD",
"id": "CVE-2025-60686"
}
]
},
"cve": "CVE-2025-60686",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"availabilityImpact": "LOW",
"baseScore": 5.1,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"exploitabilityScore": 2.5,
"id": "CVE-2025-60686",
"impactScore": 2.5,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:L",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Local",
"author": "OTHER",
"availabilityImpact": "Low",
"baseScore": 5.1,
"baseSeverity": "Medium",
"confidentialityImpact": "Low",
"exploitabilityScore": null,
"id": "JVNDB-2025-019636",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:L",
"version": "3.0"
}
],
"severity": [
{
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"id": "CVE-2025-60686",
"trust": 1.0,
"value": "MEDIUM"
},
{
"author": "OTHER",
"id": "JVNDB-2025-019636",
"trust": 0.8,
"value": "Medium"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2025-019636"
},
{
"db": "NVD",
"id": "CVE-2025-60686"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A local stack-based buffer overflow vulnerability exists in the infostat.cgi and cstecgi.cgi binaries of ToToLink routers (A720R V4.1.5cu.614_B20230630, LR1200GB V9.1.0u.6619_B20230130, and NR1800X V9.1.0u.6681_B20230703). Both programs parse the contents of /proc/net/arp using sscanf() with \"%s\" format specifiers into fixed-size stack buffers without length validation. Specifically, one function writes user-controlled data into a single-byte buffer, and the other into adjacent small arrays without bounds checking. An attacker who controls the contents of /proc/net/arp can trigger memory corruption, leading to denial of service or potential arbitrary code execution",
"sources": [
{
"db": "NVD",
"id": "CVE-2025-60686"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-019636"
}
],
"trust": 1.62
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2025-60686",
"trust": 2.6
},
{
"db": "JVNDB",
"id": "JVNDB-2025-019636",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2025-019636"
},
{
"db": "NVD",
"id": "CVE-2025-60686"
}
]
},
"id": "VAR-202511-1324",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VARIoT devices database",
"id": null
}
],
"trust": 0.29761904
},
"last_update_date": "2025-11-22T23:11:58.945000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-121",
"trust": 1.0
},
{
"problemtype": "Stack-based buffer overflow (CWE-121) [ others ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2025-019636"
},
{
"db": "NVD",
"id": "CVE-2025-60686"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.8,
"url": "https://github.com/yifan20020708/sgtaint-0-day/blob/main/totolink/totolink-a720r/cve-2025-60686.md"
},
{
"trust": 1.8,
"url": "https://www.totolink.net/"
},
{
"trust": 1.0,
"url": "http://totolink.com"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2025-60686"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2025-019636"
},
{
"db": "NVD",
"id": "CVE-2025-60686"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "JVNDB",
"id": "JVNDB-2025-019636"
},
{
"db": "NVD",
"id": "CVE-2025-60686"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-11-21T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2025-019636"
},
{
"date": "2025-11-13T16:15:52.590000",
"db": "NVD",
"id": "CVE-2025-60686"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-11-21T05:53:00",
"db": "JVNDB",
"id": "JVNDB-2025-019636"
},
{
"date": "2025-11-19T17:41:28.740000",
"db": "NVD",
"id": "CVE-2025-60686"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "plural \u00a0TOTOLINK\u00a0 Stack-based buffer overflow vulnerability in products",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2025-019636"
}
],
"trust": 0.8
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…