VAR-202507-2463
Vulnerability from variot - Updated: 2025-08-09 23:12A vulnerability classified as critical was found in TOTOLINK T6 4.1.5cu.748. This vulnerability affects the function ckeckKeepAlive of the file wireless.so of the component MQTT Packet Handler. The manipulation leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. TOTOLINK of t6 The firmware contains injection and command injection vulnerabilities.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The TOTOLINK T6 is a wireless dual-band router released by China's Jiong Electronics (TOTOLINK). It supports the MQTT protocol and Telnet service.
The TOTOLINK T6 has a command injection vulnerability caused by the ckeckKeepAlive function in the wireless.so file failing to properly sanitize special characters and commands in constructed commands. No detailed vulnerability details are currently available
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202507-2463",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "t6",
"scope": "eq",
"trust": 1.0,
"vendor": "totolink",
"version": "v4.1.5cu.748_b20211015"
},
{
"model": "t6",
"scope": "eq",
"trust": 0.8,
"vendor": "totolink",
"version": null
},
{
"model": "t6",
"scope": null,
"trust": 0.8,
"vendor": "totolink",
"version": null
},
{
"model": "t6",
"scope": "eq",
"trust": 0.8,
"vendor": "totolink",
"version": "t6 firmware v4.1.5cu.748 b20211015"
},
{
"model": "t6 4.1.5cu.748",
"scope": null,
"trust": 0.6,
"vendor": "totolink",
"version": null
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-17676"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-009713"
},
{
"db": "NVD",
"id": "CVE-2025-7952"
}
]
},
"cve": "CVE-2025-7952",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "cna@vuldb.com",
"availabilityImpact": "PARTIAL",
"baseScore": 6.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 8.0,
"id": "CVE-2025-7952",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "MEDIUM",
"trust": 1.0,
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Network",
"authentication": "Single",
"author": "OTHER",
"availabilityImpact": "Partial",
"baseScore": 6.5,
"confidentialityImpact": "Partial",
"exploitabilityScore": null,
"id": "JVNDB-2025-009713",
"impactScore": null,
"integrityImpact": "Partial",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "Medium",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "CNVD",
"availabilityImpact": "PARTIAL",
"baseScore": 6.5,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 8.0,
"id": "CNVD-2025-17676",
"impactScore": 6.4,
"integrityImpact": "PARTIAL",
"severity": "MEDIUM",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "cna@vuldb.com",
"availabilityImpact": "LOW",
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"exploitabilityScore": 2.8,
"id": "CVE-2025-7952",
"impactScore": 3.4,
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
},
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 2.8,
"id": "CVE-2025-7952",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 8.8,
"baseSeverity": "High",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "JVNDB-2025-009713",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "Low",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "cna@vuldb.com",
"id": "CVE-2025-7952",
"trust": 1.0,
"value": "Low"
},
{
"author": "nvd@nist.gov",
"id": "CVE-2025-7952",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "OTHER",
"id": "JVNDB-2025-009713",
"trust": 0.8,
"value": "High"
},
{
"author": "CNVD",
"id": "CNVD-2025-17676",
"trust": 0.6,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-17676"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-009713"
},
{
"db": "NVD",
"id": "CVE-2025-7952"
},
{
"db": "NVD",
"id": "CVE-2025-7952"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A vulnerability classified as critical was found in TOTOLINK T6 4.1.5cu.748. This vulnerability affects the function ckeckKeepAlive of the file wireless.so of the component MQTT Packet Handler. The manipulation leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. TOTOLINK of t6 The firmware contains injection and command injection vulnerabilities.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The TOTOLINK T6 is a wireless dual-band router released by China\u0027s Jiong Electronics (TOTOLINK). It supports the MQTT protocol and Telnet service. \n\nThe TOTOLINK T6 has a command injection vulnerability caused by the ckeckKeepAlive function in the wireless.so file failing to properly sanitize special characters and commands in constructed commands. No detailed vulnerability details are currently available",
"sources": [
{
"db": "NVD",
"id": "CVE-2025-7952"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-009713"
},
{
"db": "CNVD",
"id": "CNVD-2025-17676"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2025-7952",
"trust": 3.2
},
{
"db": "VULDB",
"id": "317098",
"trust": 1.8
},
{
"db": "JVNDB",
"id": "JVNDB-2025-009713",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2025-17676",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-17676"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-009713"
},
{
"db": "NVD",
"id": "CVE-2025-7952"
}
]
},
"id": "VAR-202507-2463",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-17676"
}
],
"trust": 1.09017543
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-17676"
}
]
},
"last_update_date": "2025-08-09T23:12:41.058000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-74",
"trust": 1.0
},
{
"problemtype": "CWE-77",
"trust": 1.0
},
{
"problemtype": "injection (CWE-74) [ others ]",
"trust": 0.8
},
{
"problemtype": " Command injection (CWE-77) [ others ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2025-009713"
},
{
"db": "NVD",
"id": "CVE-2025-7952"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.4,
"url": "https://github.com/elvisblue/public/blob/main/vuln/7.md"
},
{
"trust": 1.8,
"url": "https://github.com/elvisblue/public/blob/main/vuln/7.md#poc"
},
{
"trust": 1.8,
"url": "https://vuldb.com/?id.317098"
},
{
"trust": 1.8,
"url": "https://vuldb.com/?submit.619319"
},
{
"trust": 1.8,
"url": "https://www.totolink.net/"
},
{
"trust": 1.0,
"url": "https://vuldb.com/?ctiid.317098"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2025-7952"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-17676"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-009713"
},
{
"db": "NVD",
"id": "CVE-2025-7952"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2025-17676"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-009713"
},
{
"db": "NVD",
"id": "CVE-2025-7952"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-08-07T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-17676"
},
{
"date": "2025-07-24T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2025-009713"
},
{
"date": "2025-07-22T03:15:28.997000",
"db": "NVD",
"id": "CVE-2025-7952"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-08-07T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-17676"
},
{
"date": "2025-07-24T02:41:00",
"db": "JVNDB",
"id": "JVNDB-2025-009713"
},
{
"date": "2025-07-23T16:16:10.950000",
"db": "NVD",
"id": "CVE-2025-7952"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "TOTOLINK\u00a0 of \u00a0t6\u00a0 Injection Vulnerability in Firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2025-009713"
}
],
"trust": 0.8
}
}
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.