VAR-202506-0627
Vulnerability from variot - Updated: 2025-09-14 23:46Autel MaxiCharger AC Wallbox Commercial Firmware Downgrade Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Autel MaxiCharger AC Wallbox Commercial charging stations. An attacker must first obtain the ability to pair a malicious Bluetooth device with the target system in order to exploit this vulnerability.
The specific flaw exists within the firmware update process. The issue results from the lack of proper validation of a firmware image before using it to perform an upgrade. An attacker can leverage this in conjunction with other vulnerabilities to execute arbitrary code in the context of the device. Was ZDI-CAN-26354. maxicharger ac elite business c50 firmware, MaxiCharger AC Pro firmware, MaxiCharger AC Ultra firmware etc. autel The product contains a vulnerability that allows the security version number to be changed to an older version.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Autel MaxiCharger AC Wallbox Commercial is a smart AI electric vehicle charger from Autel, a US company
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202506-0627",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "maxicharger ac ultra",
"scope": "lt",
"trust": 1.0,
"vendor": "autel",
"version": "1.56.51"
},
{
"model": "maxicharger dc compact pedestal",
"scope": "lt",
"trust": 1.0,
"vendor": "autel",
"version": "1.56.51"
},
{
"model": "maxicharger dc fast",
"scope": "lt",
"trust": 1.0,
"vendor": "autel",
"version": "1.56.51"
},
{
"model": "maxicharger dc compact mobile",
"scope": "lt",
"trust": 1.0,
"vendor": "autel",
"version": "1.39.51"
},
{
"model": "maxicharger dh480",
"scope": "lt",
"trust": 1.0,
"vendor": "autel",
"version": "1.56.51"
},
{
"model": "maxicharger dc hipower",
"scope": "lt",
"trust": 1.0,
"vendor": "autel",
"version": "1.39.51"
},
{
"model": "maxicharger single charger",
"scope": "lt",
"trust": 1.0,
"vendor": "autel",
"version": "1.39.51"
},
{
"model": "maxicharger ac pro",
"scope": "lt",
"trust": 1.0,
"vendor": "autel",
"version": "1.39.51"
},
{
"model": "maxicharger ac elite business c50",
"scope": "lt",
"trust": 1.0,
"vendor": "autel",
"version": "1.56.51"
},
{
"model": "maxicharger dc compact pedestal",
"scope": "lt",
"trust": 1.0,
"vendor": "autel",
"version": "1.39.51"
},
{
"model": "maxicharger single charger",
"scope": "lt",
"trust": 1.0,
"vendor": "autel",
"version": "1.56.51"
},
{
"model": "maxicharger ac ultra",
"scope": "lt",
"trust": 1.0,
"vendor": "autel",
"version": "1.39.51"
},
{
"model": "maxicharger dc fast",
"scope": "lt",
"trust": 1.0,
"vendor": "autel",
"version": "1.39.51"
},
{
"model": "maxicharger dc hipower",
"scope": "lt",
"trust": 1.0,
"vendor": "autel",
"version": "1.56.51"
},
{
"model": "maxicharger dh480",
"scope": "lt",
"trust": 1.0,
"vendor": "autel",
"version": "1.39.51"
},
{
"model": "maxicharger ac pro",
"scope": "lt",
"trust": 1.0,
"vendor": "autel",
"version": "1.56.51"
},
{
"model": "maxicharger dc compact mobile",
"scope": "lt",
"trust": 1.0,
"vendor": "autel",
"version": "1.56.51"
},
{
"model": "maxicharger ac elite business c50",
"scope": "lt",
"trust": 1.0,
"vendor": "autel",
"version": "1.39.51"
},
{
"model": "maxicharger single charger",
"scope": null,
"trust": 0.8,
"vendor": "autel",
"version": null
},
{
"model": "maxicharger ac pro",
"scope": null,
"trust": 0.8,
"vendor": "autel",
"version": null
},
{
"model": "maxicharger dc compact mobile",
"scope": null,
"trust": 0.8,
"vendor": "autel",
"version": null
},
{
"model": "maxicharger dc compact pedestal",
"scope": null,
"trust": 0.8,
"vendor": "autel",
"version": null
},
{
"model": "maxicharger dc fast",
"scope": null,
"trust": 0.8,
"vendor": "autel",
"version": null
},
{
"model": "maxicharger ac elite business c50",
"scope": null,
"trust": 0.8,
"vendor": "autel",
"version": null
},
{
"model": "maxicharger ac ultra",
"scope": null,
"trust": 0.8,
"vendor": "autel",
"version": null
},
{
"model": "maxicharger dc hipower",
"scope": null,
"trust": 0.8,
"vendor": "autel",
"version": null
},
{
"model": "maxicharger dh480",
"scope": null,
"trust": 0.8,
"vendor": "autel",
"version": null
},
{
"model": "maxicharger ac wallbox commercial",
"scope": null,
"trust": 0.7,
"vendor": "autel",
"version": null
},
{
"model": "maxicharger ac wallbox commercial \u003cv1.39.51",
"scope": null,
"trust": 0.6,
"vendor": "autel",
"version": null
},
{
"model": "maxicharger ac wallbox commercial \u003cv1.56.51",
"scope": null,
"trust": 0.6,
"vendor": "autel",
"version": null
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-25-344"
},
{
"db": "CNVD",
"id": "CNVD-2025-14949"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-013701"
},
{
"db": "NVD",
"id": "CVE-2025-5825"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Sina Kheirkhah (@SinSinology) of Summoning Team (@SummoningTeam)",
"sources": [
{
"db": "ZDI",
"id": "ZDI-25-344"
}
],
"trust": 0.7
},
"cve": "CVE-2025-5825",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "HIGH",
"accessVector": "ADJACENT_NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 6.8,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 3.2,
"id": "CNVD-2025-14949",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "MEDIUM",
"trust": 0.6,
"vectorString": "AV:A/AC:H/Au:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "HIGH",
"attackVector": "ADJACENT",
"author": "zdi-disclosures@trendmicro.com",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 1.6,
"id": "CVE-2025-5825",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
{
"attackComplexity": "High",
"attackVector": "Adjacent Network",
"author": "OTHER",
"availabilityImpact": "High",
"baseScore": 7.5,
"baseSeverity": "High",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "JVNDB-2025-013701",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
{
"attackComplexity": "HIGH",
"attackVector": "ADJACENT",
"author": "ZDI",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 1.6,
"id": "CVE-2025-5825",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 0.7,
"userInteraction": "NONE",
"vectorString": "AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "zdi-disclosures@trendmicro.com",
"id": "CVE-2025-5825",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "OTHER",
"id": "JVNDB-2025-013701",
"trust": 0.8,
"value": "High"
},
{
"author": "ZDI",
"id": "CVE-2025-5825",
"trust": 0.7,
"value": "HIGH"
},
{
"author": "CNVD",
"id": "CNVD-2025-14949",
"trust": 0.6,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-25-344"
},
{
"db": "CNVD",
"id": "CNVD-2025-14949"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-013701"
},
{
"db": "NVD",
"id": "CVE-2025-5825"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Autel MaxiCharger AC Wallbox Commercial Firmware Downgrade Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Autel MaxiCharger AC Wallbox Commercial charging stations. An attacker must first obtain the ability to pair a malicious Bluetooth device with the target system in order to exploit this vulnerability. \n\nThe specific flaw exists within the firmware update process. The issue results from the lack of proper validation of a firmware image before using it to perform an upgrade. An attacker can leverage this in conjunction with other vulnerabilities to execute arbitrary code in the context of the device. Was ZDI-CAN-26354. maxicharger ac elite business c50 firmware, MaxiCharger AC Pro firmware, MaxiCharger AC Ultra firmware etc. autel The product contains a vulnerability that allows the security version number to be changed to an older version.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Autel MaxiCharger AC Wallbox Commercial is a smart AI electric vehicle charger from Autel, a US company",
"sources": [
{
"db": "NVD",
"id": "CVE-2025-5825"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-013701"
},
{
"db": "ZDI",
"id": "ZDI-25-344"
},
{
"db": "CNVD",
"id": "CNVD-2025-14949"
}
],
"trust": 2.79
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2025-5825",
"trust": 3.9
},
{
"db": "ZDI",
"id": "ZDI-25-344",
"trust": 3.1
},
{
"db": "JVNDB",
"id": "JVNDB-2025-013701",
"trust": 0.8
},
{
"db": "ZDI_CAN",
"id": "ZDI-CAN-26354",
"trust": 0.7
},
{
"db": "CNVD",
"id": "CNVD-2025-14949",
"trust": 0.6
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-25-344"
},
{
"db": "CNVD",
"id": "CNVD-2025-14949"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-013701"
},
{
"db": "NVD",
"id": "CVE-2025-5825"
}
]
},
"id": "VAR-202506-0627",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-14949"
}
],
"trust": 0.06
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"IoT"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-14949"
}
]
},
"last_update_date": "2025-09-14T23:46:00.438000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Patch for Autel MaxiCharger AC Wallbox Commercial Code Execution Vulnerability",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchInfo/show/704541"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-14949"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-1328",
"trust": 1.0
},
{
"problemtype": "Security version number can be changed to an older version (CWE-1328) [ others ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2025-013701"
},
{
"db": "NVD",
"id": "CVE-2025-5825"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.4,
"url": "https://www.zerodayinitiative.com/advisories/zdi-25-344/"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2025-5825"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-14949"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-013701"
},
{
"db": "NVD",
"id": "CVE-2025-5825"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "ZDI",
"id": "ZDI-25-344"
},
{
"db": "CNVD",
"id": "CNVD-2025-14949"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-013701"
},
{
"db": "NVD",
"id": "CVE-2025-5825"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-06-11T00:00:00",
"db": "ZDI",
"id": "ZDI-25-344"
},
{
"date": "2025-07-03T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-14949"
},
{
"date": "2025-09-11T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2025-013701"
},
{
"date": "2025-06-25T18:15:23.303000",
"db": "NVD",
"id": "CVE-2025-5825"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-06-11T00:00:00",
"db": "ZDI",
"id": "ZDI-25-344"
},
{
"date": "2025-07-03T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-14949"
},
{
"date": "2025-09-11T08:20:00",
"db": "JVNDB",
"id": "JVNDB-2025-013701"
},
{
"date": "2025-09-10T14:46:49.130000",
"db": "NVD",
"id": "CVE-2025-5825"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "plural \u00a0autel\u00a0 Vulnerability that allows security version numbers in products to be changed to older versions",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2025-013701"
}
],
"trust": 0.8
}
}
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.