VAR-202505-1101
Vulnerability from variot - Updated: 2025-05-30 23:17Cleartext transmission of sensitive information in the web management portal of the Tenda RX2 Pro 16.03.30.14 may allow an unauthenticated attacker to authenticate to the web management portal by collecting credentials from observed/collected traffic. It implements encryption, but not until after the user has transmitted the hash of their password in cleartext. The hash can be replayed to authenticate. Shenzhen Tenda Technology Co.,Ltd. of RX2 Pro The firmware contains a vulnerability related to plaintext storage of sensitive information.Information may be obtained and information may be tampered with. Tenda RX2 Pro is a high-performance WiFi 6 signal amplifier from China's Tenda.
Tenda RX2 Pro has an information leakage vulnerability that can be exploited by attackers to collect credentials for authentication
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202505-1101",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "rx2 pro",
"scope": "eq",
"trust": 1.6,
"vendor": "tenda",
"version": "16.03.30.14"
},
{
"model": "rx2 pro",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "rx2 pro firmware 16.03.30.14"
},
{
"model": "rx2 pro",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "rx2 pro",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-09932"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-005799"
},
{
"db": "NVD",
"id": "CVE-2025-46634"
}
]
},
"cve": "CVE-2025-46634",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "NONE",
"baseScore": 8.5,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "CNVD-2025-09932",
"impactScore": 7.8,
"integrityImpact": "PARTIAL",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:P/A:N",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"availabilityImpact": "NONE",
"baseScore": 8.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"id": "CVE-2025-46634",
"impactScore": 4.2,
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:N",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "OTHER",
"availabilityImpact": "None",
"baseScore": 8.2,
"baseSeverity": "High",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "JVNDB-2025-005799",
"impactScore": null,
"integrityImpact": "Low",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:N",
"version": "3.0"
}
],
"severity": [
{
"author": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"id": "CVE-2025-46634",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "OTHER",
"id": "JVNDB-2025-005799",
"trust": 0.8,
"value": "High"
},
{
"author": "CNVD",
"id": "CNVD-2025-09932",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-09932"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-005799"
},
{
"db": "NVD",
"id": "CVE-2025-46634"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Cleartext transmission of sensitive information in the web management portal of the Tenda RX2 Pro 16.03.30.14 may allow an unauthenticated attacker to authenticate to the web management portal by collecting credentials from observed/collected traffic. It implements encryption, but not until after the user has transmitted the hash of their password in cleartext. The hash can be replayed to authenticate. Shenzhen Tenda Technology Co.,Ltd. of RX2 Pro The firmware contains a vulnerability related to plaintext storage of sensitive information.Information may be obtained and information may be tampered with. Tenda RX2 Pro is a high-performance WiFi 6 signal amplifier from China\u0027s Tenda. \n\nTenda RX2 Pro has an information leakage vulnerability that can be exploited by attackers to collect credentials for authentication",
"sources": [
{
"db": "NVD",
"id": "CVE-2025-46634"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-005799"
},
{
"db": "CNVD",
"id": "CNVD-2025-09932"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2025-46634",
"trust": 3.2
},
{
"db": "JVNDB",
"id": "JVNDB-2025-005799",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2025-09932",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-09932"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-005799"
},
{
"db": "NVD",
"id": "CVE-2025-46634"
}
]
},
"id": "VAR-202505-1101",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-09932"
}
],
"trust": 0.06
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-09932"
}
]
},
"last_update_date": "2025-05-30T23:17:22.520000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Patch for Tenda RX2 Pro Information Disclosure Vulnerability",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchInfo/show/688166"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-09932"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-312",
"trust": 1.0
},
{
"problemtype": "Plaintext storage of important information (CWE-312) [ others ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2025-005799"
},
{
"db": "NVD",
"id": "CVE-2025-46634"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.8,
"url": "https://blog.uturn.dev/#/writeups/iot-village/tenda-rx2pro/readme?id=cve-2025-46634-transmission-of-plaintext-credentials-in-httpd"
},
{
"trust": 1.8,
"url": "https://www.tendacn.com/us/default.html"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2025-46634"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-09932"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-005799"
},
{
"db": "NVD",
"id": "CVE-2025-46634"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2025-09932"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-005799"
},
{
"db": "NVD",
"id": "CVE-2025-46634"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-05-15T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-09932"
},
{
"date": "2025-05-28T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2025-005799"
},
{
"date": "2025-05-01T20:15:39.460000",
"db": "NVD",
"id": "CVE-2025-46634"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-05-16T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-09932"
},
{
"date": "2025-05-28T08:20:00",
"db": "JVNDB",
"id": "JVNDB-2025-005799"
},
{
"date": "2025-05-27T14:18:00.567000",
"db": "NVD",
"id": "CVE-2025-46634"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a0RX2\u00a0Pro\u00a0 Vulnerability related to plaintext storage of important information in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2025-005799"
}
],
"trust": 0.8
}
}
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.