VAR-202504-1139
Vulnerability from variot - Updated: 2025-08-23 22:39A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UpdateGateways' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25915). Siemens' telecontrol server basic for, SQL There is an injection vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed.The specific flaw exists within the implementation of the UpdateGateways method. The issue results from the lack of proper validation of a user-supplied string before using it to construct SQL queries. An attacker could leverage this vulnerability to disclose stored credentials, leading to further compromise.
Siemens TeleControl Server Basic versions prior to v3.1.2.2 have multiple SQL injection vulnerabilities that can be exploited by attackers to read and write the application's database, causing a denial of service and executing code in the operating system shell with limited "NT AUTHORITYNetworkService" permissions
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202504-1139",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "telecontrol server basic",
"scope": "lt",
"trust": 1.2,
"vendor": "siemens",
"version": "v3.1.2.2"
},
{
"model": "telecontrol server basic",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "3.1.2.2"
},
{
"model": "telecontrol server basic",
"scope": "eq",
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "telecontrol server basic",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
},
{
"model": "telecontrol server basic",
"scope": "eq",
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": "3.1.2.2"
},
{
"model": "telecontrol server basic",
"scope": null,
"trust": 0.7,
"vendor": "siemens",
"version": null
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-25-395"
},
{
"db": "CNVD",
"id": "CNVD-2025-09145"
},
{
"db": "CNVD",
"id": "CNVD-2025-08398"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-011820"
},
{
"db": "NVD",
"id": "CVE-2025-31352"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Anonymous",
"sources": [
{
"db": "ZDI",
"id": "ZDI-25-395"
}
],
"trust": 0.7
},
"cve": "CVE-2025-31352",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 9.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 8.0,
"id": "CNVD-2025-09145",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "CNVD-2025-08398",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "productcert@siemens.com",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 2.8,
"id": "CVE-2025-31352",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "OTHER",
"availabilityImpact": "High",
"baseScore": 8.8,
"baseSeverity": "High",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "JVNDB-2025-011820",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "Low",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "ZDI",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 2.8,
"id": "CVE-2025-31352",
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"trust": 0.7,
"userInteraction": "NONE",
"vectorString": "AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
"version": "3.0"
}
],
"severity": [
{
"author": "productcert@siemens.com",
"id": "CVE-2025-31352",
"trust": 1.0,
"value": "High"
},
{
"author": "OTHER",
"id": "JVNDB-2025-011820",
"trust": 0.8,
"value": "High"
},
{
"author": "ZDI",
"id": "CVE-2025-31352",
"trust": 0.7,
"value": "MEDIUM"
},
{
"author": "CNVD",
"id": "CNVD-2025-09145",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "CNVD",
"id": "CNVD-2025-08398",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-25-395"
},
{
"db": "CNVD",
"id": "CNVD-2025-09145"
},
{
"db": "CNVD",
"id": "CNVD-2025-08398"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-011820"
},
{
"db": "NVD",
"id": "CVE-2025-31352"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A vulnerability has been identified in TeleControl Server Basic (All versions \u003c V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used \u0027UpdateGateways\u0027 method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application\u0027s database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25915). Siemens\u0027 telecontrol server basic for, SQL There is an injection vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed.The specific flaw exists within the implementation of the UpdateGateways method. The issue results from the lack of proper validation of a user-supplied string before using it to construct SQL queries. An attacker could leverage this vulnerability to disclose stored credentials, leading to further compromise. \n\nSiemens TeleControl Server Basic versions prior to v3.1.2.2 have multiple SQL injection vulnerabilities that can be exploited by attackers to read and write the application\u0027s database, causing a denial of service and executing code in the operating system shell with limited \"NT AUTHORITYNetworkService\" permissions",
"sources": [
{
"db": "NVD",
"id": "CVE-2025-31352"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-011820"
},
{
"db": "ZDI",
"id": "ZDI-25-395"
},
{
"db": "CNVD",
"id": "CNVD-2025-09145"
},
{
"db": "CNVD",
"id": "CNVD-2025-08398"
}
],
"trust": 3.33
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2025-31352",
"trust": 3.9
},
{
"db": "SIEMENS",
"id": "SSA-443402",
"trust": 3.0
},
{
"db": "JVN",
"id": "JVNVU90506697",
"trust": 0.8
},
{
"db": "ICS CERT",
"id": "ICSA-25-112-01",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2025-011820",
"trust": 0.8
},
{
"db": "ZDI_CAN",
"id": "ZDI-CAN-25915",
"trust": 0.7
},
{
"db": "ZDI",
"id": "ZDI-25-395",
"trust": 0.7
},
{
"db": "CNVD",
"id": "CNVD-2025-09145",
"trust": 0.6
},
{
"db": "CNVD",
"id": "CNVD-2025-08398",
"trust": 0.6
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-25-395"
},
{
"db": "CNVD",
"id": "CNVD-2025-09145"
},
{
"db": "CNVD",
"id": "CNVD-2025-08398"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-011820"
},
{
"db": "NVD",
"id": "CVE-2025-31352"
}
]
},
"id": "VAR-202504-1139",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-09145"
},
{
"db": "CNVD",
"id": "CNVD-2025-08398"
}
],
"trust": 0.12
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"ICS"
],
"sub_category": null,
"trust": 1.2
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-09145"
},
{
"db": "CNVD",
"id": "CNVD-2025-08398"
}
]
},
"last_update_date": "2025-08-23T22:39:21.500000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Siemens has issued an update to correct this vulnerability.",
"trust": 0.7,
"url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
},
{
"title": "Patch for Siemens TeleControl Server Basic SQL Injection Vulnerability (CNVD-2025-09145)",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchInfo/show/686301"
},
{
"title": "Patch for Siemens TeleControl Server Basic has multiple SQL injection vulnerabilities",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchInfo/show/684331"
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-25-395"
},
{
"db": "CNVD",
"id": "CNVD-2025-09145"
},
{
"db": "CNVD",
"id": "CNVD-2025-08398"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-89",
"trust": 1.0
},
{
"problemtype": "SQL injection (CWE-89) [ others ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2025-011820"
},
{
"db": "NVD",
"id": "CVE-2025-31352"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 3.7,
"url": "https://cert-portal.siemens.com/productcert/html/ssa-443402.html"
},
{
"trust": 0.8,
"url": "https://jvn.jp/vu/jvnvu90506697/"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2025-31352"
},
{
"trust": 0.8,
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-112-01"
}
],
"sources": [
{
"db": "ZDI",
"id": "ZDI-25-395"
},
{
"db": "CNVD",
"id": "CNVD-2025-09145"
},
{
"db": "CNVD",
"id": "CNVD-2025-08398"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-011820"
},
{
"db": "NVD",
"id": "CVE-2025-31352"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "ZDI",
"id": "ZDI-25-395"
},
{
"db": "CNVD",
"id": "CNVD-2025-09145"
},
{
"db": "CNVD",
"id": "CNVD-2025-08398"
},
{
"db": "JVNDB",
"id": "JVNDB-2025-011820"
},
{
"db": "NVD",
"id": "CVE-2025-31352"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-06-16T00:00:00",
"db": "ZDI",
"id": "ZDI-25-395"
},
{
"date": "2025-05-07T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-09145"
},
{
"date": "2025-04-16T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-08398"
},
{
"date": "2025-08-20T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2025-011820"
},
{
"date": "2025-04-16T18:16:07.520000",
"db": "NVD",
"id": "CVE-2025-31352"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-06-16T00:00:00",
"db": "ZDI",
"id": "ZDI-25-395"
},
{
"date": "2025-05-07T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-09145"
},
{
"date": "2025-04-25T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-08398"
},
{
"date": "2025-08-20T07:11:00",
"db": "JVNDB",
"id": "JVNDB-2025-011820"
},
{
"date": "2025-08-19T14:52:35.097000",
"db": "NVD",
"id": "CVE-2025-31352"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Siemens\u0027 \u00a0telecontrol\u00a0server\u00a0basic\u00a0 In \u00a0SQL\u00a0 Injection vulnerability",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2025-011820"
}
],
"trust": 0.8
}
}
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.