VAR-202411-0913

Vulnerability from variot - Updated: 2024-12-17 22:19

A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All versions < V14.3.0.12), Teamcenter Visualization V2312 (All versions < V2312.0008), Teamcenter Visualization V2406 (All versions < V2406.0005), Tecnomatix Plant Simulation V2302 (All versions < V2302.0018), Tecnomatix Plant Simulation V2404 (All versions < V2404.0007). The affected applications contain a stack based overflow vulnerability while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-24486). Siemens' Tecnomatix Plant Simulation Exists in an out-of-bounds write vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Siemens Tecnomatix Plant Simulation. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of WRL files. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. Siemens Tecnomatix Plant Simulation is an industrial control device of Siemens, Germany. It uses the function of discrete event simulation to analyze and optimize production volume, thereby improving the performance of manufacturing systems

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202411-0913",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "tecnomatix plant simulation",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2404.0007"
      },
      {
        "model": "tecnomatix plant simulation",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2302.0018"
      },
      {
        "model": "tecnomatix plant simulation",
        "scope": "gte",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "2404.0"
      },
      {
        "model": "tecnomatix plant simulation",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "tecnomatix plant simulation",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": "2404.0  that\u0027s all  2404.0007"
      },
      {
        "model": "tecnomatix plant simulation",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": "2302.0018"
      },
      {
        "model": "tecnomatix plant simulation",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "tecnomatix plant simulation",
        "scope": null,
        "trust": 0.7,
        "vendor": "siemens",
        "version": null
      },
      {
        "model": "tecnomatix plant simulation",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v2302\u003c2302.0018"
      },
      {
        "model": "tecnomatix plant simulation",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v2404\u003c2404.0007"
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-24-1518"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2024-45987"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-013137"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-52572"
      }
    ]
  },
  "credits": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/credits#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Mat Powell of Trend Micro Zero Day Initiative",
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-24-1518"
      }
    ],
    "trust": 0.7
  },
  "cve": "CVE-2024-52572",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "accessComplexity": "LOW",
            "accessVector": "LOCAL",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "COMPLETE",
            "baseScore": 7.2,
            "confidentialityImpact": "COMPLETE",
            "exploitabilityScore": 3.9,
            "id": "CNVD-2024-45987",
            "impactScore": 10.0,
            "integrityImpact": "COMPLETE",
            "severity": "HIGH",
            "trust": 0.6,
            "vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "author": "productcert@siemens.com",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 1.8,
            "id": "CVE-2024-52572",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 2.0,
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Local",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 7.8,
            "baseSeverity": "High",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2024-52572",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "None",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "Required",
            "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.0"
          },
          {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "author": "ZDI",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 1.8,
            "id": "CVE-2024-52572",
            "impactScore": 5.9,
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "trust": 0.7,
            "userInteraction": "REQUIRED",
            "vectorString": "AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "productcert@siemens.com",
            "id": "CVE-2024-52572",
            "trust": 1.0,
            "value": "High"
          },
          {
            "author": "nvd@nist.gov",
            "id": "CVE-2024-52572",
            "trust": 1.0,
            "value": "HIGH"
          },
          {
            "author": "NVD",
            "id": "CVE-2024-52572",
            "trust": 0.8,
            "value": "High"
          },
          {
            "author": "ZDI",
            "id": "CVE-2024-52572",
            "trust": 0.7,
            "value": "HIGH"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2024-45987",
            "trust": 0.6,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-24-1518"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2024-45987"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-013137"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-52572"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-52572"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions \u003c V14.2.0.14), Teamcenter Visualization V14.3 (All versions \u003c V14.3.0.12), Teamcenter Visualization V2312 (All versions \u003c V2312.0008), Teamcenter Visualization V2406 (All versions \u003c V2406.0005), Tecnomatix Plant Simulation V2302 (All versions \u003c V2302.0018), Tecnomatix Plant Simulation V2404 (All versions \u003c V2404.0007). The affected applications contain a stack based overflow vulnerability while parsing specially crafted WRL files. \r\nThis could allow an attacker to execute code in the context of the current process. (ZDI-CAN-24486). Siemens\u0027 Tecnomatix Plant Simulation Exists in an out-of-bounds write vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Siemens Tecnomatix Plant Simulation. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of WRL files. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. Siemens Tecnomatix Plant Simulation is an industrial control device of Siemens, Germany. It uses the function of discrete event simulation to analyze and optimize production volume, thereby improving the performance of manufacturing systems",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2024-52572"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-013137"
      },
      {
        "db": "ZDI",
        "id": "ZDI-24-1518"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2024-45987"
      }
    ],
    "trust": 2.79
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2024-52572",
        "trust": 3.9
      },
      {
        "db": "SIEMENS",
        "id": "SSA-824503",
        "trust": 2.4
      },
      {
        "db": "SIEMENS",
        "id": "SSA-645131",
        "trust": 1.0
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-24-347-09",
        "trust": 0.8
      },
      {
        "db": "JVN",
        "id": "JVNVU96191615",
        "trust": 0.8
      },
      {
        "db": "JVN",
        "id": "JVNVU91750786",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-013137",
        "trust": 0.8
      },
      {
        "db": "ZDI_CAN",
        "id": "ZDI-CAN-24486",
        "trust": 0.7
      },
      {
        "db": "ZDI",
        "id": "ZDI-24-1518",
        "trust": 0.7
      },
      {
        "db": "CNVD",
        "id": "CNVD-2024-45987",
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-24-1518"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2024-45987"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-013137"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-52572"
      }
    ]
  },
  "id": "VAR-202411-0913",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-45987"
      }
    ],
    "trust": 0.8745396
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2024-45987"
      }
    ]
  },
  "last_update_date": "2024-12-17T22:19:51.184000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Siemens has issued an update to correct this vulnerability.",
        "trust": 0.7,
        "url": "https://cert-portal.siemens.com/productcert/html/ssa-824503.html"
      },
      {
        "title": "Patch for Siemens Tecnomatix Plant Simulation Stack Buffer Overflow Vulnerability (CNVD-2024-45987)",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchInfo/show/628906"
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-24-1518"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2024-45987"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-787",
        "trust": 1.0
      },
      {
        "problemtype": "CWE-121",
        "trust": 1.0
      },
      {
        "problemtype": "Stack-based buffer overflow (CWE-121) [ others ]",
        "trust": 0.8
      },
      {
        "problemtype": " Out-of-bounds writing (CWE-787) [NVD evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-013137"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-52572"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 3.1,
        "url": "https://cert-portal.siemens.com/productcert/html/ssa-824503.html"
      },
      {
        "trust": 1.0,
        "url": "https://cert-portal.siemens.com/productcert/html/ssa-645131.html"
      },
      {
        "trust": 0.8,
        "url": "https://jvn.jp/vu/jvnvu96191615/"
      },
      {
        "trust": 0.8,
        "url": "https://jvn.jp/vu/jvnvu91750786/"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2024-52572"
      },
      {
        "trust": 0.8,
        "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-347-09"
      }
    ],
    "sources": [
      {
        "db": "ZDI",
        "id": "ZDI-24-1518"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2024-45987"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-013137"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-52572"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "ZDI",
        "id": "ZDI-24-1518"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2024-45987"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-013137"
      },
      {
        "db": "NVD",
        "id": "CVE-2024-52572"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2024-11-19T00:00:00",
        "db": "ZDI",
        "id": "ZDI-24-1518"
      },
      {
        "date": "2024-11-28T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2024-45987"
      },
      {
        "date": "2024-11-21T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2024-013137"
      },
      {
        "date": "2024-11-18T16:15:28.767000",
        "db": "NVD",
        "id": "CVE-2024-52572"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2024-11-19T00:00:00",
        "db": "ZDI",
        "id": "ZDI-24-1518"
      },
      {
        "date": "2024-11-26T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2024-45987"
      },
      {
        "date": "2024-12-16T07:21:00",
        "db": "JVNDB",
        "id": "JVNDB-2024-013137"
      },
      {
        "date": "2024-12-10T14:30:46.097000",
        "db": "NVD",
        "id": "CVE-2024-52572"
      }
    ]
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Siemens\u0027 \u00a0Tecnomatix\u00a0Plant\u00a0Simulation\u00a0 Out-of-bounds write vulnerability in",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2024-013137"
      }
    ],
    "trust": 0.8
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…